1
|
Antoniadou M, Schierer V, Fontana D, Kahr J, Rosenberg E. Development of a Multiplexing Injector for Gas Chromatography for the Time-Resolved Analysis of Volatile Emissions from Lithium-Ion Batteries. Molecules 2024; 29:2181. [PMID: 38792043 PMCID: PMC11123839 DOI: 10.3390/molecules29102181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 04/23/2024] [Accepted: 04/27/2024] [Indexed: 05/26/2024] Open
Abstract
Multiplex sampling, so far mainly used as a tool for S/N ratio improvement in spectroscopic applications and separation techniques, has been investigated here for its potential suitability for time-resolved monitoring where chromatograms of transient signals are recorded at intervals much shorter than the chromatographic runtime. Different designs of multiplex sample introduction were developed and utilized to analyze lithium-ion battery degradation products under normal or abuse conditions to achieve fast and efficient sample introduction. After comprehensive optimization, measurements were performed on two different GC systems, with either barrier discharge ionization detection (BID) or mass spectrometric detection (MS). Three different injector designs were examined, and modifications in the pertinent hardware components and operational conditions used. The shortest achievable sample introduction time was 50 ms with an interval of 6 s. Relative standard deviations were lower than 4% and 10% for the intra- and inter-day repeatability, respectively. The sample introduction system and column head pressure had to be carefully controlled, as this parameter most critically affects the amount of sample introduced and, thus, detector response. The newly developed sample introduction system was successfully used to monitor volatile degradation products of lithium-ion batteries and demonstrated concentration changes over the course of time of the degradation products (e.g., fluoroethane, acetaldehyde and ethane), as well as for solvents from the battery electrolyte like ethyl carbonate.
Collapse
Affiliation(s)
- Maria Antoniadou
- Institute of Chemical Technologies and Analytics, Vienna University of Technology, Getreidemarkt 9/164, A-1060 Vienna, Austria
| | - Valentin Schierer
- Electric Drive Technologies, Electromobility Department, Austrian Institute of Technology GmbH, Giefinggasse 2, A-1210 Vienna, Austria; (V.S.); (J.K.)
| | - Daniela Fontana
- FAAM Research Centre, Strada del Portone 61, I-10137 Torino, Italy
| | - Jürgen Kahr
- Electric Drive Technologies, Electromobility Department, Austrian Institute of Technology GmbH, Giefinggasse 2, A-1210 Vienna, Austria; (V.S.); (J.K.)
| | - Erwin Rosenberg
- Institute of Chemical Technologies and Analytics, Vienna University of Technology, Getreidemarkt 9/164, A-1060 Vienna, Austria
| |
Collapse
|
2
|
Zumsande S, Thoben C, Dennhardt N, Krauß T, Sümpelmann R, Zimmermann S, Rüffert H, Heiderich S. Rebounds of sevoflurane concentration during simulated trigger-free pediatric and adult anesthesia. BMC Anesthesiol 2023; 23:196. [PMID: 37291484 PMCID: PMC10249316 DOI: 10.1186/s12871-023-02148-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Accepted: 05/20/2023] [Indexed: 06/10/2023] Open
Abstract
BACKGROUND In trigger-free anesthesia a volatile anesthetic concentration of 5 parts per million (ppm) should not be exceeded. According to European Malignant Hyperthermia Group (EMHG) guideline, this may be achieved by removing the vapor, changing the anesthetic breathing circuit and renewing the soda lime canister followed by flushing with O2 or air for a workstation specific time. Reduction of the fresh gas flow (FGF) or stand-by modes are known to cause rebound effects. In this study, simulated trigger-free pediatric and adult ventilation was carried out on test lungs including ventilation maneuvers commonly used in clinical practice. The goal of this study was to evaluate whether rebounds of sevoflurane develop during trigger-free anesthesia. METHODS A Dräger® Primus® was contaminated with decreasing concentrations of sevoflurane for 120 min. Then, the machine was prepared for trigger-free anesthesia according to EMHG guideline by changing recommended parts and flushing the breathing circuits using 10 or 18 l⋅min- 1 FGF. The machine was neither switched off after preparation nor was FGF reduced. Simulated trigger-free ventilation was performed with volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) including various ventilation maneuvers like pressure support ventilation (PSV), apnea, decreased lung compliance (DLC), recruitment maneuvers, prolonged expiration and manual ventilation (MV). A high-resolution ion mobility spectrometer with gas chromatographic pre-separation was used to measure sevoflurane in the ventilation gas mixture in a 20 s interval. RESULTS Immediately after start of simulated anesthesia, there was an initial peak of 11-18 ppm sevoflurane in all experiments. The concentration dropped below 5 ppm after 2-3 min during adult and 4-18 min during pediatric ventilation. Other rebounds of sevoflurane > 5 ppm occurred after apnea, DLC and PSV. MV resulted in a decrease of sevoflurane < 5 ppm within 1 min. CONCLUSION This study shows that after guideline-compliant preparation for trigger-free ventilation anesthetic machines may develop rebounds of sevoflurane > 5 ppm during typical maneuvers used in clinical practice. The changes in rate and direction of internal gas flow during different ventilation modes and maneuvers are possible explanations. Therefore, manufacturers should provide machine-specific washout protocols or emphasize the use of active charcoal filters (ACF) for trigger-free anesthesia.
Collapse
Affiliation(s)
- Simon Zumsande
- Clinic of Anesthesiology and Intensive Care Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | - Christian Thoben
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Hannover, Germany
| | - Nils Dennhardt
- Clinic of Anesthesiology and Intensive Care Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | - Terence Krauß
- Clinic of Anesthesiology and Intensive Care Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | - Robert Sümpelmann
- Clinic of Anesthesiology and Intensive Care Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | - Stefan Zimmermann
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Hannover, Germany
| | - Henrik Rüffert
- Clinic of Anesthesiology and Intensive Care Medicine, Helios Klinik Schkeuditz, Leipzig, Germany
| | - Sebastian Heiderich
- Clinic of Anesthesiology and Intensive Care Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
| |
Collapse
|
3
|
SAKITA R, KISHI H, IIGUNI Y, KITAGAWA S, OHTANI H. Fundamental Study for Increasing Multiplicity of Frequency Division Multiplex HPLC-MS. CHROMATOGRAPHY 2022. [DOI: 10.15583/jpchrom.2022.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Affiliation(s)
- Ren SAKITA
- Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology
| | - Hiroka KISHI
- Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology
| | - Yoshinori IIGUNI
- Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology
| | - Shinya KITAGAWA
- Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology
| | - Hajime OHTANI
- Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology
| |
Collapse
|
4
|
Wahab MF, Gritti F, O'Haver TC. Discrete Fourier transform techniques for noise reduction and digital enhancement of analytical signals. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116354] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
5
|
Wunsch MR, Reiter AMC, Schuster FS, Lehnig R, Trapp O. Continuous online process analytics with multiplexing gas chromatography by using calibrated convolution matrices. J Chromatogr A 2019; 1595:180-189. [PMID: 30803787 DOI: 10.1016/j.chroma.2019.02.034] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2018] [Revised: 02/11/2019] [Accepted: 02/14/2019] [Indexed: 11/26/2022]
Abstract
The development of fast and precise measurement techniques for process analytical technology is important to operate chemical processes safely and efficiently. For quantitative measurements of multiple components at a trace level, often gas chromatographic methods are used which have a response time of several minutes or of up to one hour. For fast changing processes, this can be too slow for efficient control. For reducing the dead time of a control loop by increasing the measurement frequency, a multiplexing gas chromatography (mpGC) technique for a chromatographic system exhibiting a systematic non-linear response has been developed. For mpGC, superimposed chromatograms are measured by injecting consecutive samples before all components of previous samples have eluted from the column. The deconvolution of a superimposed chromatogram yields a computed chromatogram which is an average over the single chromatograms forming the superimposed chromatogram. Such a computed chromatogram typically shows so called correlation noise depending on the degree by which the single chromatograms forming the superimposed chromatogram will differ from each other (non-linear response). A technique is presented to calibrate the convolution matrix in order to suppress correlation noise introduced by systematic errors of the chromatographic system. The remaining correlation noise in the computed chromatogram is then exclusively caused by changing concentrations in the sample stream. For the method presented here, the sample is injected five times during the run time of a single chromatogram. The computed chromatogram is obtained three times within this timespan while representing each time an averaged chromatogram over the last five injections. Therefore, the sample throughput is increased by a factor of three compared to conventional GC.
Collapse
Affiliation(s)
- Marco R Wunsch
- BASF SE, Carl-Bosch-Str. 38, 67056 Ludwigshafen, Germany
| | | | | | - Rudolf Lehnig
- BASF SE, Carl-Bosch-Str. 38, 67056 Ludwigshafen, Germany
| | - Oliver Trapp
- Department Chemie, Ludwig-Maximilians-Universität München, Butenandtstr. 5-13, Munich, Germany.
| |
Collapse
|
6
|
Kishi H, Kumazaki T, Kitagawa S, Ohtani H. Frequency division multiplex HPLC-MS for simultaneous analyses. Analyst 2019; 144:2922-2928. [PMID: 30912777 DOI: 10.1039/c8an02352b] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Multiplex high-performance liquid chromatograph-mass spectrometry (HPLC-MS), in which multiple HPLCs and one MS are hyphenated, is an approach for high throughput analysis in HPLC-MS. A general multiplex HPLC-MS method employs a column-switching technology, and only one HPLC is connected to one MS at a time. In the present study, we propose a novel multiplex HPLC-MS system for simultaneous HPLC-MS analyses. In this study, multiple HPLCs are hyphenated with one MS without a column-switching mechanism, and a mixed-chromatogram is observed by the MS. Here, we employ a frequency division multiplexing (FDM) technique used in communication engineering to extract any chromatogram from the mixed-chromatogram. When a modulator (chopper or ion-gate type) is set between each ion source and the MS, each modulator blocks each sample stream with an individual frequency. In theory, each chromatogram can be extracted from the mixed-chromatogram via a signal processing based on a Fourier transform (FT), frequency-based signal extraction, and reversed FT. In the actual experiment, two HPLCs are hyphenated with one MS (2HPLC-1MS). The use of chopper type modulators leads to the extraction and restoration of each chromatogram from the mixed-chromatogram. However, each restored-chromatogram involves signal interference. On the other hand, the ion-gate modulation system successfully resulted in restored-chromatograms without interference. The potential of the novel multiplex HPLC-MS system based on FDM is confirmed with respect to the simultaneous and continuous analyses of plural samples.
Collapse
Affiliation(s)
- Hiroka Kishi
- Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology, Gokiso, Showa, Nagoya 466-8555, Japan.
| | - Takashi Kumazaki
- Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology, Gokiso, Showa, Nagoya 466-8555, Japan.
| | - Shinya Kitagawa
- Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology, Gokiso, Showa, Nagoya 466-8555, Japan.
| | - Hajime Ohtani
- Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology, Gokiso, Showa, Nagoya 466-8555, Japan.
| |
Collapse
|
7
|
Ishikawa S, Zhang Z, Murayama T, Hiyoshi N, Sadakane M, Ueda W. Multi-dimensional Crystal Structuring of Complex Metal Oxide Catalysts of Group V and VI Elements by Unit-Assembling. Top Catal 2018. [DOI: 10.1007/s11244-018-1077-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|