1
|
Stutzman JR, Hutchins PD, Bain RM. Online Bipolar Dual Spray for the Charge State Reduction and Characterization of Complex Synthetic Polymers. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:2840-2848. [PMID: 38053368 DOI: 10.1021/jasms.3c00333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/07/2023]
Abstract
Charge reduction mass spectrometry (CR/MS) hyphenated to liquid chromatography (LC) couples liquid-phase compound separation and mass spectral decompression to resolve and characterize multicomponent systems. LC/CR/MS has proven to be effective for complex mixture analysis, particularly synthetic polymers. A newer charge manipulation approach called bipolar dual spray has previously been demonstrated to reduce the observed charge state distribution of ammoniated polyethene glycol. In this approach, two electrospray emitters, in close proximity and of opposite polarity, fuse droplets from their electrospray plumes, which allows the subsequent chemistry. In this work, we investigate the ability of bipolar dual spray to reduce the charge of synthetic polyols, thereby simplifying complex mixture analysis and generating new compositional information only available through the coupling of charge reduction with LC/MS analysis. This work also represents the first demonstration of online charge reduction via dual spray. Polyethylene glycol (PEG) 7.2K subjected to LC/MS with dual spray reduced the average charge state from 8.2+ to 4.4+. LC/MS with dual spray was also applied to the characterization of an end-group-modified PEG 10K (i.e., aminated) containing several reaction impurities. This approach allowed for the identification of low-level starting material, tosylated PEG, and PEG mono(amine), where both LC/MS and direct infusion dual spray did not detect the impurities. Overall, the results demonstrated that bipolar dual spray can be incorporated into an LC/MS analysis and affords the ability to reduce the charge state distribution of PEG cations, decompress the m/z axis, lower spectra complexity, and enable/simplify data interpretation.
Collapse
Affiliation(s)
- John R Stutzman
- Analytical Sciences, Dow Inc., Midland, Michigan 48640, United States
| | - Paul D Hutchins
- Analytical Sciences, Dow Inc., Midland, Michigan 48640, United States
| | - Ryan M Bain
- Analytical Sciences, Dow Inc., Midland, Michigan 48640, United States
| |
Collapse
|
2
|
Hua Y, Strauss M, Fisher S, Mauser MFX, Manchet P, Smacchia M, Geyer P, Shayeghi A, Pfeffer M, Eggenweiler TH, Daly S, Commandeur J, Mayor M, Arndt M, Šolomek T, Köhler V. Giving the Green Light to Photochemical Uncaging of Large Biomolecules in High Vacuum. JACS AU 2023; 3:2790-2799. [PMID: 37885583 PMCID: PMC10598566 DOI: 10.1021/jacsau.3c00351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 10/02/2023] [Accepted: 10/02/2023] [Indexed: 10/28/2023]
Abstract
The isolation of biomolecules in a high vacuum enables experiments on fragile species in the absence of a perturbing environment. Since many molecular properties are influenced by local electric fields, here we seek to gain control over the number of charges on a biopolymer by photochemical uncaging. We present the design, modeling, and synthesis of photoactive molecular tags, their labeling to peptides and proteins as well as their photochemical validation in solution and in the gas phase. The tailored tags can be selectively cleaved off at a well-defined time and without the need for any external charge-transferring agents. The energy of a single or two green photons can already trigger the process, and it is soft enough to ensure the integrity of the released biomolecular cargo. We exploit differences in the cleavage pathways in solution and in vacuum and observe a surprising robustness in upscaling the approach from a model system to genuine proteins. The interaction wavelength of 532 nm is compatible with various biomolecular entities, such as oligonucleotides or oligosaccharides.
Collapse
Affiliation(s)
- Yong Hua
- Department
of Chemistry, University of Basel, St. Johannsring 19, CH-4056 Basel, Switzerland
| | - Marcel Strauss
- Vienna
Faculty of Physics, University of Vienna,
VDSP & VCQ, Boltzmanngasse 5, A-1090 Vienna, Austria
| | - Sergey Fisher
- Van’t
Hoff Institute for Molecular Sciences (HIMS), University of Amsterdam, PO Box 94157, 1090 GD Amsterdam, The Netherlands
| | - Martin F. X. Mauser
- Vienna
Faculty of Physics, University of Vienna,
VDSP & VCQ, Boltzmanngasse 5, A-1090 Vienna, Austria
| | - Pierre Manchet
- Vienna
Faculty of Physics, University of Vienna,
VDSP & VCQ, Boltzmanngasse 5, A-1090 Vienna, Austria
| | - Martina Smacchia
- Vienna
Faculty of Physics, University of Vienna,
VDSP & VCQ, Boltzmanngasse 5, A-1090 Vienna, Austria
| | - Philipp Geyer
- Vienna
Faculty of Physics, University of Vienna,
VDSP & VCQ, Boltzmanngasse 5, A-1090 Vienna, Austria
| | - Armin Shayeghi
- Vienna
Faculty of Physics, University of Vienna,
VDSP & VCQ, Boltzmanngasse 5, A-1090 Vienna, Austria
| | - Michael Pfeffer
- Department
of Chemistry, University of Basel, St. Johannsring 19, CH-4056 Basel, Switzerland
| | - Tim Henri Eggenweiler
- Department
of Chemistry, University of Basel, St. Johannsring 19, CH-4056 Basel, Switzerland
| | - Steven Daly
- MS
Vision, Televisieweg
40, 1322 AM Almere, The Netherlands
| | - Jan Commandeur
- MS
Vision, Televisieweg
40, 1322 AM Almere, The Netherlands
| | - Marcel Mayor
- Department
of Chemistry, University of Basel, St. Johannsring 19, CH-4056 Basel, Switzerland
- Institute
for Nanotechnology (INT), Karlsruhe Institute
of Technology (KIT), P.O. Box 3640, DE-76021 Karlsruhe Eggenstein-Leopoldshafen, Germany
- Lehn Institute
of Functional Materials, School of Chemistry, Sun Yat-Sen University, Guangzhou 510274, P. R. China
| | - Markus Arndt
- Vienna
Faculty of Physics, University of Vienna,
VDSP & VCQ, Boltzmanngasse 5, A-1090 Vienna, Austria
| | - Tomáš Šolomek
- Van’t
Hoff Institute for Molecular Sciences (HIMS), University of Amsterdam, PO Box 94157, 1090 GD Amsterdam, The Netherlands
| | - Valentin Köhler
- Department
of Chemistry, University of Basel, St. Johannsring 19, CH-4056 Basel, Switzerland
| |
Collapse
|
3
|
Fernandez de la Mora J, Perez-Lorenzo LJ, Wick D. Singularly Narrow Viral Size and Mobility Standards from the 38.3 nm Chronic Bee Paralysis Virus and Its 17.5 nm Satellite. Anal Chem 2020; 92:13896-13903. [PMID: 32969651 DOI: 10.1021/acs.analchem.0c02687] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
The chronic bee paralysis virus (CBPV), extracted from sick or dead bees, was studied by mobility measurements via electrospray charge reduction with a differential mobility analyzer (DMA) of unusually high resolution. Three different particles are observed. The most abundant one contributes a mobility peak at 38.3 nm, approximately as expected for CBPV. The peak is very sharp in spite of the nonisometric nature of CBPV. We also observe a previously unreported weaker well-resolved shoulder 4.8% more mobile, perhaps due to empty (genome-free) particles. Another sharp peak appearing at approximately 17.51 nm is likely associated with the known icosahedral CBPV satellite (CBPVS). The 17.51 and 38.3 nm peaks offer size and mobility standards much narrower than previously reported at any size above 5 nm, with relative full peak width at half-maximum (FWHM) in mobility approaching 2% (∼1% in diameter). Slight but clear imperfections in the DMA response and the electrospraying process suggest that the real width of the viral mobility distribution is less than 2%.
Collapse
Affiliation(s)
- Juan Fernandez de la Mora
- Department of Mechanical Engineering and Materials Science, Yale University, New Haven, Connecticut 06520, United States
| | - Luis Javier Perez-Lorenzo
- Department of Mechanical Engineering and Materials Science, Yale University, New Haven, Connecticut 06520, United States
| | - David Wick
- BVS, Inc., Stevensville, Montana 59870, United States
| |
Collapse
|
4
|
Stutzman JR, Bain RM, Hagenhoff S, Woodward WH, O'Brien JP, Lesniak M. Microdroplet Fusion Chemistry for Charge State Reduction of Synthetic Polymers via Bipolar Dual Spray with Anionic Reagents. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:1742-1749. [PMID: 31140078 DOI: 10.1007/s13361-019-02236-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 04/15/2019] [Accepted: 04/18/2019] [Indexed: 06/09/2023]
Abstract
Microdroplet fusion chemistry is an emerging area of analyte manipulation that utilizes the ion source region of a mass spectrometer to covalently derivatize or manipulate the charge state distribution. This technique utilizes two electrospray emitters in close proximity, where the droplets from each electrospray plume fuse and undergo the subsequent chemistry. In this study, microdroplet fusion chemistry via bipolar dual spray has demonstrated the ability to reduce the average charge state of polyethylene glycol (PEG) cations using anionic reagents. Bipolar dual spray was implemented on a commercial mass spectrometer with limited hardware modifications to the ion source. Reagents including ammonium hydroxide, formic acid, and lithium chloride showed dramatic shifts in the average charge state of PEG 3.8 K cations (e.g., 5.0+ to 2.5+) along with the emergence of newly detected charge states. An organic base, tributylamine, had no effect on the charge state distribution of PEG 3.8 K cations. These results were consistent with an ion-pairing mechanism, where reagent anions destabilized ammonium cation interactions with PEG 3.8 K upon droplet fusion from the negative and positive emitters. Additional bipolar dual spray experiments with PEG 12.6 K demonstrated the ability to transform uninterpretable mass information into distinct charge states ranging from [M+8NH4]+ to [M+3NH4]+. Overall, this study provides insight into the nature of dual spray chemistry and will aid future experimental design in microdroplet covalent chemistry.
Collapse
Affiliation(s)
- John R Stutzman
- Analytical Sciences, The Dow Chemical Company, 1897 Building, Midland, MI, 48667, USA.
| | - Ryan M Bain
- Analytical Sciences, The Dow Chemical Company, 1897 Building, Midland, MI, 48667, USA
| | - Sebastian Hagenhoff
- Analytical Sciences, Dow Deutschland Anlagengesellschaft mbH, 21677, Stade, Germany
| | - William H Woodward
- Analytical Sciences, The Dow Chemical Company, 1897 Building, Midland, MI, 48667, USA
| | - John P O'Brien
- Plastics Characterization, The Dow Chemical Company, Lake Jackson, TX, 77566, USA
| | - Michael Lesniak
- Analytical Sciences, The Dow Chemical Company, 1897 Building, Midland, MI, 48667, USA
| |
Collapse
|
5
|
Burnum-Johnson KE, Zheng X, Dodds JN, Ash J, Fourches D, Nicora CD, Wendler JP, Metz TO, Waters KM, Jansson JK, Smith RD, Baker ES. Ion Mobility Spectrometry and the Omics: Distinguishing Isomers, Molecular Classes and Contaminant Ions in Complex Samples. Trends Analyt Chem 2019; 116:292-299. [PMID: 31798197 DOI: 10.1016/j.trac.2019.04.022] [Citation(s) in RCA: 75] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Ion mobility spectrometry (IMS) is a widely used analytical technique providing rapid gas phase separations. IMS alone is useful, but its coupling with mass spectrometry (IMS-MS) and various front-end separation techniques has greatly increased the molecular information achievable from different omic analyses. IMS-MS analyses are specifically gaining attention for improving metabolomic, lipidomic, glycomic, proteomic and exposomic analyses by increasing measurement sensitivity (e.g. S/N ratio), reducing the detection limit, and amplifying peak capacity. Numerous studies including national security-related analyses, disease screenings and environmental evaluations are illustrating that IMS-MS is able to extract information not possible with MS alone. Furthermore, IMS-MS has shown great utility in salvaging molecular information for low abundance molecules of interest when high concentration contaminant ions are present in the sample by reducing detector suppression. This review highlights how IMS-MS is currently being used in omic analyses to distinguish structurally similar molecules, isomers, molecular classes and contaminant ions.
Collapse
Affiliation(s)
| | - Xueyun Zheng
- Department of Chemistry, Texas A &M University, College Station, TX
| | - James N Dodds
- Department of Chemistry, NC State University, Raleigh, NC
| | - Jeremy Ash
- Department of Chemistry, NC State University, Raleigh, NC
| | - Denis Fourches
- Department of Chemistry, NC State University, Raleigh, NC
| | - Carrie D Nicora
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA
| | - Jason P Wendler
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA
| | - Thomas O Metz
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA
| | - Katrina M Waters
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA
| | - Janet K Jansson
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA
| | - Richard D Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA
| | - Erin S Baker
- Department of Chemistry, NC State University, Raleigh, NC
| |
Collapse
|