1
|
Ishtaweera P, Baker GA. Progress in the application of ionic liquids and deep eutectic solvents for the separation and quantification of per- and polyfluoroalkyl substances. JOURNAL OF HAZARDOUS MATERIALS 2024; 465:132959. [PMID: 38118198 DOI: 10.1016/j.jhazmat.2023.132959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 10/31/2023] [Accepted: 11/06/2023] [Indexed: 12/22/2023]
Abstract
Per- and polyfluoroalkyl substances (PFASs), often labeled as "forever chemicals," earned this moniker due to their widespread presence in the environment, bioaccumulative tendencies, and resistance to remediation efforts. Employed for decades in various applications, spanning from stain-resistant fabrics to grease-proof food containers and fire-fighting foams, PFASs have evolved into an anthropogenic nightmare. Their adverse impact on human health, including immune dysfunction, infertility, and a spectrum of cancers, is alarming. Conventional water treatment methods, notably in the case of short-chain congeners, struggle to effectively eliminate PFASs, underscoring the pressing need for enhanced adsorbents. In recent years, there has been a prominent surge in the exploration of innovative techniques centered around ionic liquids (ILs) and deep eutectic solvents (DESs) for the removal of PFASs from various sources, including food samples like cooking oil, as well as environmental waters. In this Review, we delve into key advancements and discoveries related to the utilization of ILs and DESs as media for the liquid-liquid extraction of PFASs, as well as their applications as sorbents on solid-state or nanoscale supports. Our exploration encompasses groundbreaking approaches, including the utilization of dicationic ILs for ultra-sensitive mass spectrometric PFAS detection, alongside the innovative application of fluorinated ILs and hydrophobic DESs, enabling highly efficient PFAS sequestration. The landscape of existing PFAS extraction methods is riddled with formidable challenges, including limited selectivity, matrix interferences, subpar extraction efficiency, exorbitant costs, laborious procedures, ecological consequences, and a lack of standardization. Given these challenges, our review unequivocally asserts the pivotal role ILs and DESs will play in shaping the next generation of PFAS remediation strategies. Rigorous characterization of water solubility, toxicity, and biodegradation, along with improved recyclability and thorough techno-economic analyses, are essential for further progress. Future focus must also extend to addressing short-chain PFASs (such as PFBS) and PFAS alternatives (including ADONA, GenX, F-53B), which often pose higher toxicity risks than the compounds they aim to replace. A forward-thinking approach will integrate cutting-edge data-driven techniques, such as machine learning, to enhance our understanding and response to PFAS-related issues. Finally, we advocate seamless integration of PFAS separation with advanced treatment, efficiently isolating and destroying these compounds for a lasting solution to contamination challenges.
Collapse
Affiliation(s)
- Piyuni Ishtaweera
- Department of Chemistry, University of Missouri, Columbia, MO 65211, USA
| | - Gary A Baker
- Department of Chemistry, University of Missouri, Columbia, MO 65211, USA.
| |
Collapse
|
2
|
Dong S, Zhang N, Yi M, Zhang J, Di D, Deng J, Li L, Hu B. Slug-Flow Microextraction Mass Spectrometry for Enhanced Detection of Analytes in Human Tear Fluids using Noninvasive Microsampling and Nanoelectrospray Ionization via a Capillary. Anal Chem 2023; 95:16054-16058. [PMID: 37852267 DOI: 10.1021/acs.analchem.3c03683] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2023]
Abstract
In vivo noninvasive sampling and sensitive analysis of human tear fluids at the microliter level is an important but challenging task in investigating eye health. In this work, capillary microsampling coupled with slug-flow microextraction mass spectrometry (SFME-MS) was developed for enhanced detection of analytes in human tear fluids. As low as 1.0 μL of human tear fluid could be directly sampled using a capillary, and extraction/spray solvent was then loaded into the capillary to perform slug-flow microextraction and direct nanoelectrospray ionization (nESI) of analytes. All analytical procedures, including tear microsampling, microextraction, and ionization of analytes, were performed using a capillary. Enhanced detection of therapeutic drugs and disease biomarkers in human tear fluids was successfully demonstrated. Acceptable analytical performances including sensitivity, reproducibility, and quantitation were obtained. It is found that the use of SFME could improve the nESI-MS detection of trace analytes over 100-fold that depends on the chemical properties of analytes. Overall, this study showed that SFME-nESI-MS is a highly effective method for enhanced detection of trace analytes in tear fluids and is expected to be a potentially powerful tool in significant biological and clinical applications.
Collapse
Affiliation(s)
- Songbin Dong
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| | - Ning Zhang
- Ophthalmology Department, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710064, China
| | - Man Yi
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| | - Jianfeng Zhang
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| | - Dandan Di
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| | - Jiewei Deng
- School of Biomedical and Pharmaceutical Sciences, Smart Medical Innovation Technology Center, Guangdong University of Technology, Guangzhou 510006, China
| | - Lei Li
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| | - Bin Hu
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| |
Collapse
|
3
|
Online coupling of matrix solid-phase dispersion to direct analysis in real time mass spectrometry for high-throughput analysis of regulated chemicals in consumer products. Anal Chim Acta 2023; 1239:340677. [PMID: 36628757 DOI: 10.1016/j.aca.2022.340677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2022] [Revised: 11/23/2022] [Accepted: 11/24/2022] [Indexed: 11/27/2022]
Abstract
The current work is the first study on online coupling of matrix solid-phase dispersion (MSPD) to direct analysis in real time mass spectrometry (DART-MS) bridging with solid-phase analytical derivatization (SPAD) based on a graphene oxide nanosheets (GONs)-coated cotton swab. Proof-of-concept demonstrations were explored for high-throughput analysis of a diversity of regulated chemicals in consumer products such as textiles, toys, and cosmetics. On-demand sorbent combinations were blended with samples, packed into MSPD columns, and mounted on a homemade 3D-printed rack module for automated sample feeding. To achieve good synergy between MSPD and DART-MS, a cotton swab with a conical tip deposited with GONs was attached to the bottom of the MSPD column. The swabs serve as a solid-phase microextraction probe for convenient enrichment of the eluted analytes from MSPD, thermal desorption of the enriched analytes by DART, and sensitive detection by a hybrid quadrupole-Orbitrap mass spectrometer. Furthermore, the utility of an on-swab SPAD strategy was demonstrated for the detection of formaldehyde by use of the derivatizing reagent of dansyl hydrazine, contributing to improved ionization efficiency without compromising the overall coherence of the analytical workflow. The MSPD-DART-MS methodology was systematically optimized and validated, obtaining acceptable recovery (71.7-110.3%), repeatability (11.8-19.3%), and sensitivity (limits of detection and quantitation in the ranges of 6.2-19.5 and 23.7-75.9 μg/kg) for 32 target analytes. The developed protocol streamlined sample extraction, clean-up, desorption, ionization, and detection, highlighting the appealing potential for high-throughput analysis of samples with complex matrices.
Collapse
|
4
|
Chen M, Li M, Zhang W, Bai H, Ma Q. Natural Deep Eutectic Solvent-Based Dispersive Liquid-Liquid Microextraction Coupled with Direct Analysis in Real Time Mass Spectrometry: A Green Temperature-Mediated Analytical Strategy. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2022; 70:10919-10928. [PMID: 36000560 DOI: 10.1021/acs.jafc.2c03561] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Green analytical chemistry (GAC) represents a rapidly growing research field that aims at developing novel analytical approaches with minimal consumption of hazardous reagents and solvents. The current study reports on a GAC methodology exploiting the unique physicochemical properties of natural deep eutectic solvents (NADESs), a supposedly environmentally friendly class of solvents. Based on a temperature-mediated strategy, the NADESs were manipulated to undergo multiple phase transitions for favorable functionality and performance. As proof-of-concept demonstrations, both hydrophobic and hydrophilic NADESs were prepared for the extraction and analysis of eight phthalate esters in aqueous samples (food simulants) and three aflatoxins in oily samples (edible oils), respectively. NADES-based dispersive liquid-liquid microextraction (DLLME) was employed to achieve high-efficiency sample pretreatment. Afterward, the NADESs were transformed from liquids into solids by tuning the peripheral temperature for a convenient phase separation from the sample matrices. The solidified NADES extracts were melted and vaporized at elevated temperatures by transmission-mode direct analysis in real time (DART) for further quadrupole-Orbitrap high-resolution mass spectrometry (Q-Orbitrap HRMS) analysis. The developed protocol was validated, achieving good repeatability with relative standard deviations (RSDs) of less than 9% and satisfactory sensitivity with limits of detection (LODs) and quantitation (LOQs) ranging from 0.1 to 0.8 and 0.2 to 2.0 μg/kg, respectively. The greenness of the analytical methodology was assessed with the calculated scores of 0.66 and 0.57 for the hydrophobic and hydrophilic NADES-based protocols, respectively. The method was applied to marketed samples, highlighting the great potential for green chemical analysis.
Collapse
Affiliation(s)
- Meng Chen
- Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Ming Li
- School of Electrical and Control Engineering, North China University of Technology, Beijing 100144, China
| | - Wenxi Zhang
- Shaanxi Product Quality Supervision and Inspection Institute, Xi'an 710048, China
| | - Hua Bai
- Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Qiang Ma
- Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| |
Collapse
|
5
|
Chen M, Shang Y, Bai H, Ma Q. Electromembrane Extraction and Dual-Channel Nanoelectrospray Ionization Coupled with a Miniature Mass Spectrometer: Incorporation of a Dicationic Ionic Liquid-Induced Charge Inversion Strategy. Anal Chem 2022; 94:9472-9480. [PMID: 35737371 DOI: 10.1021/acs.analchem.2c01921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Green analytical chemistry aims at developing analytical methods with minimum use and generation of hazardous substances for the protection of human health and the environment. To address this need, a green analytical protocol has been developed for the analysis of anionic compounds integrating electromembrane extraction (EME), dual-channel nanoelectrospray ionization (nanoESI), and a miniature mass spectrometer. Haloacetic acids (HAAs) have attracted considerable public concern due to their adverse effects on human health and were selected as model analytes for method development. A flat membrane EME device was developed and assembled in-house. Optimization of fundamental operational parameters was performed using single-factor test and response surface methodology. Both the EME acceptor phase and an imidazolium-based dicationic ionic liquid (DIL), 1,1-bis(3-methylimidazolium-1-yl) butylene difluoride (C4(MIM)2F2), were subjected to dual-channel nanoESI and miniature mass spectrometry analysis based on a charge inversion strategy, where positively charged complexes were formed. Enhancement in signal intensity by as much as 2 magnitudes was achieved in the positive-ion mode compared to the negative-ion mode in the absence of the dicationic ion-pairing agent. The developed protocol was validated, obtaining good recoveries ranging from 82.7 to 109.9% and satisfactory sensitivity with limits of detection (LODs) and quantitation (LOQs) in the ranges of 1-5 and 2-10 μg/L, respectively. The greenness of the analytical procedure was assessed with a calculated score of 0.71, indicating a high degree of greenness. The developed method was applied to the analysis of real environmental or municipal water samples (n = 16), exhibiting appealing potential for outside-the-laboratory applications.
Collapse
Affiliation(s)
- Meng Chen
- Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Yuhan Shang
- Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Hua Bai
- Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Qiang Ma
- Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| |
Collapse
|
6
|
Dueñas-Mas MJ, Ballesteros-Gómez A, Rubio S. Supramolecular solvent-based microextraction probe for fast detection of bisphenols by ambient mass spectrometry. CHEMOSPHERE 2022; 294:133719. [PMID: 35077738 DOI: 10.1016/j.chemosphere.2022.133719] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 01/18/2022] [Accepted: 01/20/2022] [Indexed: 06/14/2023]
Abstract
In this study, we investigated for the first time the suitability of supramolecular solvent (SUPRAS)-based microextraction probe for the development of generic and fast sample treatment prior to qualitative analysis by ambient mass spectrometry (AMS) based on ASAP (atmospheric solids analysis probe). SUPRAS are nanostructured liquids formed by the self-assembly of amphiphilic aggregates with multiple binding sites and microenvironments of different polarity for the efficient extraction of multiple compounds. Different types of SUPRAS were evaluated as a simple and single step sample treatment for ASAP. The method was applied to the screening of bisphenol A and structural analogues in thermal paper. Optimal results were achieved with SUPRAS synthesized with 1-decanol in mixtures of ethanol:water. SUPRAS (1.1-2 μL) were loaded onto glass probes and placed in contact with samples for 10 s before ASAP analysis. AMS signal peaks (width: 0.2-0.5 min) were easily integrated and normalized with internal standards (RSD: 2-25%). The method was applied to 62 samples of thermal paper. BPA and BPS were the most widely used, this highlighting the progressive industrial replacement of BPA by BPS.
Collapse
Affiliation(s)
- María Jesús Dueñas-Mas
- Department of Analytical Chemistry, Institute of Fine Chemistry and Nanochemistry, Marie Curie Building Annex, Campus of Rabanales, University of Córdoba, 14071, Córdoba, Spain
| | - Ana Ballesteros-Gómez
- Department of Analytical Chemistry, Institute of Fine Chemistry and Nanochemistry, Marie Curie Building Annex, Campus of Rabanales, University of Córdoba, 14071, Córdoba, Spain.
| | - Soledad Rubio
- Department of Analytical Chemistry, Institute of Fine Chemistry and Nanochemistry, Marie Curie Building Annex, Campus of Rabanales, University of Córdoba, 14071, Córdoba, Spain
| |
Collapse
|
7
|
Insights into coacervative and dispersive liquid-phase microextraction strategies with hydrophilic media – A review. Anal Chim Acta 2021; 1143:225-249. [DOI: 10.1016/j.aca.2020.08.022] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 08/10/2020] [Accepted: 08/12/2020] [Indexed: 12/18/2022]
|
8
|
Li G, Lv Y, Chen M, Ye X, Niu Z, Bai H, Lei H, Ma Q. Post-Chromatographic Dicationic Ionic Liquid-Based Charge Complexation for Highly Sensitive Analysis of Anionic Compounds by Ultra-High-Performance Supercritical Fluid Chromatography Coupled with Electrospray Ionization Mass Spectrometry. Anal Chem 2020; 93:1771-1778. [PMID: 33382576 DOI: 10.1021/acs.analchem.0c04612] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
A green analytical strategy has been developed for the analysis of 10 perfluorinated compounds (PFCs) incorporating supramolecular solvent (SUPRAS)-based extraction and ultra-high-performance supercritical fluid chromatography (UHPSFC)-tandem mass spectrometry. The SUPRAS was prepared through self-assembly of reverse micelles by mixing heptanol, tetrahydrofuran, and water at optimized volume ratios. An imidazolium-based germinal dicationic ionic liquid (DIL), 1,1-bis(3-methylimidazolium-1-yl) butylene difluoride ([C4(MIM)2]F2), was dissolved in the make-up solvent of UHPSFC and introduced post-column but before the electrospray ionization source. After chromatographic separation on a Torus DIOL analytical column (100 mm × 2.1 mm, 1.7 μm), the PFC analytes associated with the DIL reagent through charge complexation. The formation of positively charged complexes resulted in improved ionization efficiency and analytical sensitivity. Enhancement in signal intensity by one to two magnitudes was achieved in the positive ionization mode compared to the negative ionization mode without using the dicationic ion-pairing reagent. The developed protocol was applied to 32 samples of real textiles and 6 samples of real food packaging materials, which exhibited great potential for the analysis of anionic compounds.
Collapse
Affiliation(s)
- Guoping Li
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China.,School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China
| | - Yueguang Lv
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China.,School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Meng Chen
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Xiwen Ye
- Technology Center of Qingdao Customs District, Qingdao 266002, China
| | - Zengyuan Niu
- Technology Center of Qingdao Customs District, Qingdao 266002, China
| | - Hua Bai
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Haimin Lei
- School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China
| | - Qiang Ma
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| |
Collapse
|