1
|
Niu C, Yan M, Yao Z, Dou J. Antibiotic residues in milk and dairy products in China: occurrence and human health concerns. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:113138-113150. [PMID: 37851252 DOI: 10.1007/s11356-023-30312-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 10/03/2023] [Indexed: 10/19/2023]
Abstract
Although veterinary antibiotics are essential in preventing and treating clinical diseases in cattle, the frequent use of antibiotics leads to antibiotic residues in milk and dairy products, consequently threatening human health. The massive milk consumption makes it necessary to assess antibiotic pollution and health impact comprehensively. Hence, we conducted a systematic review to evaluate antibiotics in milk and dairy products and their potential health risk. We searched four databases using multiple keyword combinations to retrieve 1582 pieces of literature and finally included eighteen articles to analyze antibiotic residues in milk and dairy products. These studies detected seven antibiotics in different regions of China. Quinolones and β-lactam antibiotics exceeded the MRL for raw and commercial milk. The maximum levels of sulfonamides and tetracyclines were detected in the same raw milk sample, exceeding the MRL. The estimated THQ and HI values in milk and dairy products are less than 1 for adults, indicating negligible noncarcinogenic health risk of antibiotics through consuming milk and dairy products. Children face higher health risks than adults, with the HI and THQ of quinolones exceeding 1. It is worth noting that quinolones accounted for nearly 89% of health risks associated with all antibiotics. Finally, we put forward possible research directions in the future, such as specific health effects of total dietary exposure to low levels of antibiotics. In addition, policymakers should effectively improve this problem from the perspectives of antibiotic use supervision, antibiotic residue analysis in food, and continuous environmental monitoring and control.
Collapse
Affiliation(s)
- Chenyue Niu
- School of Ecology and Environment, Beijing Technology and Business University, Beijing, 100048, China
| | - Meilin Yan
- School of Ecology and Environment, Beijing Technology and Business University, Beijing, 100048, China
- State Environmental Protection Key Laboratory of Food Chain Pollution Control, Beijing Technology and Business University, Beijing, 100048, China
- Food Flavor and Nutrition Health Innovation Center, Beijing Technology and Business University, Beijing, 100048, China
| | - Zhiliang Yao
- School of Ecology and Environment, Beijing Technology and Business University, Beijing, 100048, China.
- State Environmental Protection Key Laboratory of Food Chain Pollution Control, Beijing Technology and Business University, Beijing, 100048, China.
- Food Flavor and Nutrition Health Innovation Center, Beijing Technology and Business University, Beijing, 100048, China.
| | - Jiahang Dou
- School of Ecology and Environment, Beijing Technology and Business University, Beijing, 100048, China
| |
Collapse
|
2
|
Carthy É, Hughes B, Higgins E, Early P, Merne C, Walsh D, Parle-McDermott A, Kinahan DJ. Automated solid phase DNA extraction on a lab-on-a-disc with two-degrees of freedom instrumentation. Anal Chim Acta 2023; 1280:341859. [PMID: 37858565 DOI: 10.1016/j.aca.2023.341859] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 09/15/2023] [Accepted: 09/29/2023] [Indexed: 10/21/2023]
Abstract
BACKGROUND Lab-on-a-disc (LoaD) technology has emerged as a transformative approach for point-of-care diagnostics and high-throughput testing. The promise of integrating multiple laboratory functions onto a single integrated platform has significant implications for healthcare, especially in resource-limited settings. However, one of the primary challenges faced in the design and manufacture of LoaD devices is the integration of effective valving mechanisms. These valves are essential for fluid control and routing, but their intricacy often leads to complexities in design and increased vulnerability to failure. This emphasizes the need for improved designs and manufacturing processes without complex, integrated valving mechanisms. (96) RESULTS: We describe a fully automated biological workflow and reagent actuation on a LoaD device without an integrated valving system. The Two Degrees-of-Freedom (2DoF) custom centrifuge alters the centre of rotation, facilitating fluid flow direction changes on the microfluidic platform through a custom programmed interface. A novel 360-degree fluid manipulation approach via secondary planetary gear motion enabled sequential assay reagent actuation without embedded valve triggering, with the addition of infinite incubation times and efficient use of platform realty. The simplified LoaD platform uses clever design, with intermediate flow chambers to avoid cross contamination between reagent steps. Notably, the optimized LoaD platform demonstrated a two-fold DNA yield at higher HEK-293 cell concentrations compared to commercially available spin-column kits. This significantly simplified LoaD platform successfully automated a common, complex workflow without inhibiting DNA purification. (129) SIGNIFICANCE: This system exhibits the clever coupling of both 2DoF and centrifugal microfluidics to create an autonomous testing package capable of eradicating the need for complex valving systems to automate biological workflows on LoaDs. This automated system has outperformed commercially available DNA extraction kits for higher cell counts. The platform's elimination of valve requirements ensures unlimited sample incubation times and enhances reliability, making it a straightforward option for automated biological workflows, particularly in diagnostics. (73).
Collapse
Affiliation(s)
- Éadaoin Carthy
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland; National Centre for Sensor Research (NCSR), Dublin City University, Dublin, Ireland; Biodesign Europe, Dublin City University, Dublin, Ireland.
| | - Brian Hughes
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland
| | - Eimear Higgins
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland
| | - Phil Early
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland
| | - Cian Merne
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland
| | - Darren Walsh
- School of Biotechnology, Dublin City University, Glasnevin, Dublin, Ireland
| | - Anne Parle-McDermott
- National Centre for Sensor Research (NCSR), Dublin City University, Dublin, Ireland; School of Biotechnology, Dublin City University, Glasnevin, Dublin, Ireland
| | - David J Kinahan
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland; National Centre for Sensor Research (NCSR), Dublin City University, Dublin, Ireland; Biodesign Europe, Dublin City University, Dublin, Ireland
| |
Collapse
|
3
|
Zhu J, Kou J, Ma L, Yu X, Li C, Wang Z, Shen J, Wen K, Yu W. Molecular Recognition Mechanism of an Anti-Amatoxins mAb and Its Application in Centrifugal Disk-Based Immunoassay. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2023; 71:13889-13898. [PMID: 37695809 DOI: 10.1021/acs.jafc.3c03442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/13/2023]
Abstract
Amatoxins are polypeptides that cause 90% of fatalities from accidental ingestion of poisonous mushrooms. Unfortunately, there are no specific antidotes against amatoxins poisoning, hence preparation of high-affinity antibodies, understanding the receptor (amatoxins) and ligand (antibody) mechanism, and establishing a straightforward screening approach are of great significance for confirming poison agents and clinical diagnosis. Here, anti-amatoxins monoclonal antibody (mAb) 9B2 was prepared and the recognition mechanism was investigated. The approach is useful for designing desirable immunogens, developing new antibodies with improved performance, and constructing effective immunoassays. Based on the mAb, we designed a centrifugal disk-like microfluidics chip and developed a fully automated immunoassay capable of detecting amatoxins poisoning in various samples including serum, urine, and mushrooms. The whole detection process could be automatically accomplished within 30 min, with a limit of detection of 0.08 to 0.12 μg/L for real samples, ∼30-fold more sensitive than conventional enzyme-linked immunosorbent assay (ELISA). Our platform not only provided a practical approach for performing poison agent confirmation and clinical diagnosis but also had important implications for improving the survival of patients with mushroom poisoning.
Collapse
Affiliation(s)
- Jianyu Zhu
- National Key Laboratory of Veterinary Public Health and Safety, College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193 Beijing, People's Republic of China
- School of Basic Medicine, Beihua University, 132013 Jilin, People's Republic of China
| | - Jiaqian Kou
- National Key Laboratory of Veterinary Public Health and Safety, College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193 Beijing, People's Republic of China
| | - Licai Ma
- National Key Laboratory of Veterinary Public Health and Safety, College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193 Beijing, People's Republic of China
| | - Xuezhi Yu
- National Key Laboratory of Veterinary Public Health and Safety, College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193 Beijing, People's Republic of China
| | - Chenglong Li
- National Key Laboratory of Veterinary Public Health and Safety, College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193 Beijing, People's Republic of China
- College of Veterinary Medicine, Henan Agricultural University, 450002 Zhengzhou, People's Republic of China
| | - Zhanhui Wang
- National Key Laboratory of Veterinary Public Health and Safety, College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193 Beijing, People's Republic of China
| | - Jianzhong Shen
- National Key Laboratory of Veterinary Public Health and Safety, College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193 Beijing, People's Republic of China
| | - Kai Wen
- National Key Laboratory of Veterinary Public Health and Safety, College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193 Beijing, People's Republic of China
| | - Wenbo Yu
- National Key Laboratory of Veterinary Public Health and Safety, College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193 Beijing, People's Republic of China
| |
Collapse
|
4
|
Kong J, Xu X, Ma Y, Miao J, Bian X. Rapid and Sensitive Detection of Sulfamethizole Using a Reusable Molecularly Imprinted Electrochemical Sensor. Foods 2023; 12:foods12081693. [PMID: 37107488 PMCID: PMC10137692 DOI: 10.3390/foods12081693] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 04/14/2023] [Accepted: 04/17/2023] [Indexed: 04/29/2023] Open
Abstract
Efficient methods for monitoring sulfonamides (SAs) in water and animal-source foods are of great importance to achieve environmental safety and protect human health. Here, we demonstrate a reusable and label-free electrochemical sensor for the rapid and sensitive detection of sulfamethizole based on an electropolymerized molecularly imprinted polymer (MIP) film as the recognition layer. To achieve effective recognition, monomer screening among four kinds of 3-substituted thiophenes was performed by computational simulation and subsequent experimental evaluation, and 3-thiopheneethanol was finally selected. MIP synthesis is very fast and green, and can be in situ fabricated on the transducer surface within 30 min in an aqueous solution. The preparation process of the MIP was characterized by electrochemical techniques. Various parameters affecting MIP fabrication and its recognition response were investigated in detail. Under optimized experimental conditions, good linearity in the range of 0.001-10 μM and a low determination limit of 0.18 nM were achieved for sulfamethizole. The sensor showed excellent selectivity, which can distinguish between structurally similar SAs. In addition, the sensor displayed good reusability and stability. Even after 7 days of storage, or being reused 7 times, higher than 90% of the initial determination signals were retained. The practical applicability of the sensor was also demonstrated in spiked water and milk samples at the nM determination level with satisfactory recoveries. Compared to relevant methods for SAs, this sensor is more convenient, rapid, economical, and eco-friendly, and had comparable or even higher sensitivity, which offered a simple and efficient method for SA detection.
Collapse
Affiliation(s)
- Jie Kong
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
| | - Xiaoli Xu
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
| | - Yixin Ma
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
| | - Junjian Miao
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
| | - Xiaojun Bian
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
- Laboratory of Quality and Safety Risk Assessment for Aquatic Product on Storage and Preservation (Shanghai), Ministry of Agriculture, Shanghai 201306, China
- Shanghai Engineering Research Center of Aquatic-Product Processing & Preservation, Shanghai 201306, China
| |
Collapse
|
5
|
Cai G, Huang Y, Chen B, Shen Y, Shi X, Peng B, Mi S, Huang J. Modular design of centrifugal microfluidic system and its application in nucleic acid screening. Talanta 2023; 259:124486. [PMID: 37060723 DOI: 10.1016/j.talanta.2023.124486] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 03/22/2023] [Accepted: 03/24/2023] [Indexed: 04/17/2023]
Abstract
Modular integration of functional components on the chip and increasement in control accuracy through real-time alteration in the force direction of droplets is an effective way to optimize centrifugal microfluidic systems and realize passive components, compact modules, and high-throughput control. Conventional centrifugal microfluidic chips are mainly driven and controlled by centrifugal force and Euler force. The control valves are easily affected by machining precision, making the control unstable. In this study, a novel centrifugal microfluidic system is introduced to improve the freedom and accuracy of chip control while facilitating the design and addition of passive functional components. Furthermore, we modularize the centrifugal microfluidic chip to greatly shorten the period of design and optimization cycle and achieve chip reusability and multi-threaded control. Finally, to verify the feasibility of the modular centrifugal microfluidic chip applied to high-throughput nucleic acid screening, we test the nucleic acid purification and detection colorimetric reactions based on the modular centrifugal microfluidic chip. Among them, Chelex-100 is used to realize the purification of nucleic acid in cell lysate, and the purified solution can realize amplification in the PCR instrument, and the nucleic acid detection results are consistent with the off-chip kit by experimental testing. The system has great flexibility and stability under the acceptable purity of nucleic acid, which indicates that the platform has great potential for large-scale rapid screening applications.
Collapse
Affiliation(s)
- Gangpei Cai
- Bio-manufacturing Engineering Laboratory, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, Guangdong, China; Shenzhen Disiontech Bio-Meditech Co., Ltd., Shenzhen, 518055, Guangdong, China
| | - Yuxin Huang
- Bio-manufacturing Engineering Laboratory, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, Guangdong, China
| | - Bailiang Chen
- Bio-manufacturing Engineering Laboratory, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, Guangdong, China
| | - Yuemin Shen
- Bio-manufacturing Engineering Laboratory, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, Guangdong, China
| | - Xiaolu Shi
- Microbiology Laboratory, Shenzhen Center for Disease Control and Prevention, Nanshan District, Shenzhen, 518055, Guangdong, China
| | - Bo Peng
- Microbiology Laboratory, Shenzhen Center for Disease Control and Prevention, Nanshan District, Shenzhen, 518055, Guangdong, China
| | - Shengli Mi
- Bio-manufacturing Engineering Laboratory, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, Guangdong, China; Research Institute of Tsinghua University in Shenzhen, Nanshan District, Shenzhen, China.
| | - Jiajun Huang
- Bio-manufacturing Engineering Laboratory, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, Guangdong, China; Research Institute of Tsinghua University in Shenzhen, Nanshan District, Shenzhen, China; Shenzhen Disiontech Bio-Meditech Co., Ltd., Shenzhen, 518055, Guangdong, China.
| |
Collapse
|
6
|
Ji C, Zhou L, Chen Y, Fang X, Liu Y, Du M, Lu X, Li Q, Wang H, Sun Y, Lan T, Ma J. Microfluidic-LAMP chip for the point-of-care detection of gene-deleted and wild-type African swine fever viruses and other four swine pathogens. Front Vet Sci 2023; 10:1116352. [PMID: 36876016 PMCID: PMC9978214 DOI: 10.3389/fvets.2023.1116352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Accepted: 02/01/2023] [Indexed: 02/18/2023] Open
Abstract
Introduction Different pathogens causing mixed infection are now threatening the pig industry in the context of the African Swine Fever (ASF) circulating especially in China, and it is crucial to achieving the early diagnosis of these pathogens for disease control and prevention. Methods Here we report the development of a rapid, portable, sensitive, high-throughput, and accurate microfluidic-LAMP chip detection system for simultaneous detection and differentiation of gene-deleted type and wild-type African swine fever virus (ASFV), pseudorabie virus (PRV), porcine parvovirus (PPV), porcine circovirus type 2 (PCV2), and porcine reproductive and respiratory syndrome (PRRSV). Results and discussion The newly developed system was shown to be sensitive with detection limits of 101 copies/μl for ASFV-MGF505-2R/P72, PPV, and PCV2, 102 copies/μl for ASFV-CD2v, PRV, and PRRSV. The system was highly specific (100%) and stable (C.V.s < 5%) in its ability to detect different pathogens. A total 213 clinical samples and 15 ASFV nucleic acid samples were collected to assess the performance of the detection system, showing highly effective diagnosis. Altogether, the developed microfluidic-LAMP chip system provides a rapid, sensitive, high-throughput and portable diagnostic tool for the accurate detection of multiple swine pathogens.
Collapse
Affiliation(s)
- Chihai Ji
- Guangdong Provincial Key Lab of Agro-Animal Genomics and Molecular Breeding, College of Animal Science, South China Agricultural University, Guangzhou, Guangdong, China.,Guangdong Laboratory for Lingnan Modern Agriculture, College of Animal Science, South China Agricultural University, Guangzhou, China.,African Swine Fever Regional Laboratory of China, College of Veterinary Medicine, South China Agricultural University, Guangzhou, China
| | - Ling Zhou
- Guangdong Provincial Key Lab of Agro-Animal Genomics and Molecular Breeding, College of Animal Science, South China Agricultural University, Guangzhou, Guangdong, China.,Guangdong Laboratory for Lingnan Modern Agriculture, College of Animal Science, South China Agricultural University, Guangzhou, China
| | - Yonghui Chen
- Guangdong Provincial Key Lab of Agro-Animal Genomics and Molecular Breeding, College of Animal Science, South China Agricultural University, Guangzhou, Guangdong, China.,Guangdong Laboratory for Lingnan Modern Agriculture, College of Animal Science, South China Agricultural University, Guangzhou, China
| | - Xueen Fang
- Department of Chemistry and Institutes of Biomedical Sciences, Fudan University, Shanghai, China
| | - Yanhong Liu
- Ningbo iGene Technology Co., Ltd., Ningbo, China
| | - Mengkan Du
- Hangzhou Xiaoshan District Animal Husbandry and Veterinary Development Center, Xiaoshan Bureau of Animal Husbandry and Veterinary, Hangzhou, China
| | - Xiandong Lu
- Ningbo iGene Technology Co., Ltd., Ningbo, China
| | - Qianniu Li
- Guangdong Provincial Key Lab of Agro-Animal Genomics and Molecular Breeding, College of Animal Science, South China Agricultural University, Guangzhou, Guangdong, China.,Guangdong Laboratory for Lingnan Modern Agriculture, College of Animal Science, South China Agricultural University, Guangzhou, China
| | - Heng Wang
- Guangdong Laboratory for Lingnan Modern Agriculture, College of Animal Science, South China Agricultural University, Guangzhou, China.,African Swine Fever Regional Laboratory of China, College of Veterinary Medicine, South China Agricultural University, Guangzhou, China
| | - Yuan Sun
- Guangdong Provincial Key Lab of Agro-Animal Genomics and Molecular Breeding, College of Animal Science, South China Agricultural University, Guangzhou, Guangdong, China.,Guangdong Laboratory for Lingnan Modern Agriculture, College of Animal Science, South China Agricultural University, Guangzhou, China
| | - Tian Lan
- Guangdong Provincial Key Lab of Agro-Animal Genomics and Molecular Breeding, College of Animal Science, South China Agricultural University, Guangzhou, Guangdong, China.,Guangdong Laboratory for Lingnan Modern Agriculture, College of Animal Science, South China Agricultural University, Guangzhou, China
| | - Jingyun Ma
- Guangdong Provincial Key Lab of Agro-Animal Genomics and Molecular Breeding, College of Animal Science, South China Agricultural University, Guangzhou, Guangdong, China.,Guangdong Laboratory for Lingnan Modern Agriculture, College of Animal Science, South China Agricultural University, Guangzhou, China
| |
Collapse
|
7
|
Recent development of microfluidic biosensors for the analysis of antibiotic residues. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
8
|
Pan Y, Yang H, Wen K, Ke Y, Shen J, Wang Z. Current advances in immunoassays for quinolones in food and environmental samples. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
9
|
Iakovlev AP, Erofeev AS, Gorelkin PV. Novel Pumping Methods for Microfluidic Devices: A Comprehensive Review. BIOSENSORS 2022; 12:956. [PMID: 36354465 PMCID: PMC9688261 DOI: 10.3390/bios12110956] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 10/26/2022] [Accepted: 10/28/2022] [Indexed: 06/02/2023]
Abstract
This review is an account of methods that use various strategies to control microfluidic flow control with high accuracy. The reviewed systems are divided into two large groups based on the way they create flow: passive systems (non-mechanical systems) and active (mechanical) systems. Each group is presented by a number of device fabrications. We try to explain the main principles of operation, and we list advantages and disadvantages of the presented systems. Mechanical systems are considered in more detail, as they are currently an area of increased interest due to their unique precision flow control and "multitasking". These systems are often applied as mini-laboratories, working autonomously without any additional operations, provided by humans, which is very important under complicated conditions. We also reviewed the integration of autonomous microfluidic systems with a smartphone or single-board computer when all data are retrieved and processed without using a personal computer. In addition, we discuss future trends and possible solutions for further development of this area of technology.
Collapse
Affiliation(s)
| | | | - Petr V. Gorelkin
- Research Laboratory of Biophysics, National University of Science and Technology «MISiS», 119049 Moscow, Russia
| |
Collapse
|
10
|
A sensitive photoelectrochemical aptasensor for enrofloxacin detection based on plasmon-sensitized bismuth-rich bismuth oxyhalide. Talanta 2022; 246:123515. [DOI: 10.1016/j.talanta.2022.123515] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Revised: 02/04/2022] [Accepted: 04/24/2022] [Indexed: 01/24/2023]
|
11
|
Electrified lab on disc systems: A comprehensive review on electrokinetic applications. Biosens Bioelectron 2022; 214:114381. [DOI: 10.1016/j.bios.2022.114381] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 04/24/2022] [Accepted: 05/13/2022] [Indexed: 11/21/2022]
|
12
|
|
13
|
Tang M, Zhang C, Ta L, Tan L, Zhang M, Xu D. Fully Automatic Multi-Class Multi-Residue Analysis of Veterinary Drugs Simultaneously in an Integrated Chip-MS Platform. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2021; 69:14320-14329. [PMID: 34779203 DOI: 10.1021/acs.jafc.1c05235] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Microfluidic chip analysis has great potential advantages such as high integration, fast speed analysis, and automatic operation and is widely used not only in biological fields but also in many other analytical areas such as agriculture and food safety. Herein, a fully automatic multi-class multi-residue analysis of veterinary drugs simultaneously in an integrated chip-mass spectrometry (chip-MS) platform was developed. The developed microfluidic chip platform integrated three modules including the extraction and filtration module, "pass-through" clean-up module, and online evaporation module. The resulting chip has been coupled to a MS detector successfully, in which 23 kinds of residues in five classes were simultaneously qualitatively and quantitatively detected without chromatographic separation, obtaining the limits of detection of the spiked milk sample in the range of 0.23-4.13 ng/mL and the recovery rate in the range from 71.7 to 118.0% under optimized conditions. The microfluidic chip system developed in this study provided a new idea for the development of detection chips and exhibited considerable potential in the point-of-care testing in milk.
Collapse
Affiliation(s)
- Minmin Tang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
- Jiangsu Key Laboratory of Food Quality and Safety-State Key Laboratory Cultivation Base of Ministry of Science and Technology, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China
| | - Chenchen Zhang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
| | - La Ta
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
| | - Li Tan
- NMPA Key Laboratory for Impurity Profile of Chemical Drugs, Jiangsu Institute for Food and Drug Control, Nanjing 210008, China
| | - Mei Zhang
- NMPA Key Laboratory for Impurity Profile of Chemical Drugs, Jiangsu Institute for Food and Drug Control, Nanjing 210008, China
| | - Danke Xu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
| |
Collapse
|
14
|
Ng HY, Lee WC, Kung CT, Li LC, Lee CT, Fu LM. Recent Advances in Microfluidic Devices for Contamination Detection and Quality Inspection of Milk. MICROMACHINES 2021; 12:558. [PMID: 34068982 PMCID: PMC8156775 DOI: 10.3390/mi12050558] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 05/05/2021] [Accepted: 05/11/2021] [Indexed: 02/08/2023]
Abstract
Milk is a necessity for human life. However, it is susceptible to contamination and adulteration. Microfluidic analysis devices have attracted significant attention for the high-throughput quality inspection and contaminant analysis of milk samples in recent years. This review describes the major proposals presented in the literature for the pretreatment, contaminant detection, and quality inspection of milk samples using microfluidic lab-on-a-chip and lab-on-paper platforms in the past five years. The review focuses on the sample separation, sample extraction, and sample preconcentration/amplification steps of the pretreatment process and the determination of aflatoxins, antibiotics, drugs, melamine, and foodborne pathogens in the detection process. Recent proposals for the general quality inspection of milk samples, including the viscosity and presence of adulteration, are also discussed. The review concludes with a brief perspective on the challenges facing the future development of microfluidic devices for the analysis of milk samples in the coming years.
Collapse
Affiliation(s)
- Hwee-Yeong Ng
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung 833, Taiwan; (H.-Y.N.); (W.-C.L.); (L.-C.L.); (C.-T.L.)
| | - Wen-Chin Lee
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung 833, Taiwan; (H.-Y.N.); (W.-C.L.); (L.-C.L.); (C.-T.L.)
| | - Chia-Te Kung
- Department of Emergency Medicine, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung 833, Taiwan;
| | - Lung-Chih Li
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung 833, Taiwan; (H.-Y.N.); (W.-C.L.); (L.-C.L.); (C.-T.L.)
| | - Chien-Te Lee
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung 833, Taiwan; (H.-Y.N.); (W.-C.L.); (L.-C.L.); (C.-T.L.)
| | - Lung-Ming Fu
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan
| |
Collapse
|
15
|
Henderson BD, Kinahan DJ, Rio J, Mishra R, King D, Torres-Delgado SM, Mager D, Korvink JG, Ducrée J. Siphon-Controlled Automation on a Lab-on-a-Disc Using Event-Triggered Dissolvable Film Valves. BIOSENSORS-BASEL 2021; 11:bios11030073. [PMID: 33800811 PMCID: PMC8000095 DOI: 10.3390/bios11030073] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 02/24/2021] [Accepted: 03/02/2021] [Indexed: 12/14/2022]
Abstract
Within microfluidic technologies, the centrifugal microfluidic “Lab-on-a-Disc” (LoaD) platform offers great potential for use at the PoC and in low-resource settings due to its robustness and the ability to port and miniaturize ‘wet bench’ laboratory protocols. We present the combination of ‘event-triggered dissolvable film valves’ with a centrifugo-pneumatic siphon structure to enable control and timing, through changes in disc spin-speed, of the release and incubations of eight samples/reagents/wash buffers. Based on these microfluidic techniques, we integrated and automated a chemiluminescent immunoassay for detection of the CVD risk factor marker C-reactive protein displaying a limit of detection (LOD) of 44.87 ng mL−1 and limit of quantitation (LoQ) of 135.87 ng mL−1.
Collapse
Affiliation(s)
- Brian D. Henderson
- School of Physical Sciences, Dublin City University, Dublin 9, Ireland; (B.D.H.); (J.R.)
| | - David J. Kinahan
- School of Mechanical Engineering, Dublin City University, Dublin 9, Ireland;
- National Center for Sensor Research, Dublin City University, Dublin 9, Ireland
- I-Form, the SFI Research Centre for Advanced Manufacturing, Dublin City University, Dublin 9, Ireland
- The Water Institute, Dublin City University, Dublin 9, Ireland
| | - Jeanne Rio
- School of Physical Sciences, Dublin City University, Dublin 9, Ireland; (B.D.H.); (J.R.)
| | - Rohit Mishra
- Fraunhofer Project Center, Dublin City University, Dublin 9, Ireland; (R.M.); (D.K.)
| | - Damien King
- Fraunhofer Project Center, Dublin City University, Dublin 9, Ireland; (R.M.); (D.K.)
| | - Sarai M. Torres-Delgado
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, 76344 Karlsruhe, Germany; (S.M.T.-D.); (D.M.); (J.G.K.)
| | - Dario Mager
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, 76344 Karlsruhe, Germany; (S.M.T.-D.); (D.M.); (J.G.K.)
| | - Jan G. Korvink
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, 76344 Karlsruhe, Germany; (S.M.T.-D.); (D.M.); (J.G.K.)
| | - Jens Ducrée
- School of Physical Sciences, Dublin City University, Dublin 9, Ireland; (B.D.H.); (J.R.)
- Correspondence: ; Tel.: +353-1-700-5377
| |
Collapse
|
16
|
Jurinjak Tušek A, Šalić A, Valinger D, Jurina T, Benković M, Kljusurić JG, Zelić B. The power of microsystem technology in the food industry – Going small makes it better. INNOV FOOD SCI EMERG 2021. [DOI: 10.1016/j.ifset.2021.102613] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
17
|
Duplex Surface Enhanced Raman Scattering-Based Lateral Flow Immunosensor for the Low-Level Detection of Antibiotic Residues in Milk. Molecules 2020; 25:molecules25225249. [PMID: 33187181 PMCID: PMC7698115 DOI: 10.3390/molecules25225249] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 10/28/2020] [Accepted: 11/02/2020] [Indexed: 11/18/2022] Open
Abstract
A duplex surface enhanced Raman scattering (SERS)-based lateral flow immunosensor was established for the simultaneous detection of two common antibiotic residues including tetracycline and penicillin in milk. The newly synthesized Au@Ag nanoparticles were labeled with different Raman molecules including 5,5-dithiobis-2-nitrobenzoic acid (DTNB) or 4-mercaptobenzoic acid (MBA), followed by the conjugation of anti-tetracycline monoclonal antibody or anti-penicillin receptor, forming two kinds of SERS nanoprobes. The two nanoprobes can recognize tetracycline-BSA and ampicillin-BSA, respectively, which facilitates the simultaneous detection of the two types of antibiotics on a single test line. After optimization, detection limits of tetracycline and penicillin as low as 0.015 ng/mL and 0.010 ng/mL, respectively, were achieved. These values were far below those of most of other documented bio-analytical approaches. Moreover, the spiking test demonstrates an excellent assay accuracy with recoveries of 88.8% to 111.3%, and satisfactory assay precision with relative standard deviation below 16%. Consequently, the results demonstrate that the SERS-based lateral flow immunosensor developed in this study has the advantages of excellent assay sensitivity and remarkable multiplexing capability, thus it will have great application potential in food safety monitoring.
Collapse
|
18
|
Xia L, Yang J, Su R, Zhou W, Zhang Y, Zhong Y, Huang S, Chen Y, Li G. Recent Progress in Fast Sample Preparation Techniques. Anal Chem 2019; 92:34-48. [DOI: 10.1021/acs.analchem.9b04735] [Citation(s) in RCA: 60] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Ling Xia
- School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Jiani Yang
- School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Rihui Su
- School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Wanjun Zhou
- School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Yanshu Zhang
- School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Yanhui Zhong
- School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Simin Huang
- School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Yanlong Chen
- School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Gongke Li
- School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| |
Collapse
|