1
|
Yoon NG, Choi D, Lee JH, Kim SY, Im JY, Yun J, Yang S, Kim T, Kang S, Kang BH. Development of a Fluorescence Probe for High-Throughput Screening of Allosteric Inhibitors Targeting TRAP1. J Med Chem 2024; 67:21421-21437. [PMID: 39568139 DOI: 10.1021/acs.jmedchem.4c02343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2024]
Abstract
Tumor necrosis factor receptor-associated protein 1 (TRAP1) is a molecular chaperone implicated in pro-tumorigenic pathways by regulating the folding of substrate proteins (clients) within cancer cells. Recent research has pinpointed a potentially druggable allosteric site within the client binding site (CBS) of TRAP1, suggesting this site might offer a more effective strategy for developing potent and selective TRAP1 inhibitors. However, the absence of reliable assay systems has hindered quantitative evaluation of inhibitors. In this study, we have developed a fluorescent probe, Rho6TPP, designed to target the CBS. Utilizing fluorescence polarization-based high-throughput screening assays, Rho6TPP exhibits excellent signal-to-noise ratio (>20), Z factor (>0.6), and Z' factor (>0.6). Additionally, it facilitates comparative analysis of existing small molecules and discovery of novel binders. MitoTam, a mitochondria-targeted tamoxifen, emerges as a potent CBS-targeting TRAP1 inhibitor. Our findings highlight the potential of Rho6TPP as a crucial tool for advancing the development of CBS-targeting TRAP1 inhibitors.
Collapse
Affiliation(s)
- Nam Gu Yoon
- Department of Biological Sciences, Ulsan National Institutes of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | - Danbi Choi
- College of Pharmacy, Ewha Womans University, Seoul 03760, Republic of Korea
| | - Ji Hye Lee
- Department of Biological Sciences, Ulsan National Institutes of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | - So-Yeon Kim
- Department of Biological Sciences, Ulsan National Institutes of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | - Jin Young Im
- SmartinBio Inc., Cheongju 28160, Republic of Korea
| | - Jisu Yun
- College of Pharmacy, Ewha Womans University, Seoul 03760, Republic of Korea
| | - Sujae Yang
- College of Pharmacy, Ewha Womans University, Seoul 03760, Republic of Korea
| | - Taeeun Kim
- College of Pharmacy, Ewha Womans University, Seoul 03760, Republic of Korea
| | - Soosung Kang
- College of Pharmacy, Ewha Womans University, Seoul 03760, Republic of Korea
| | - Byoung Heon Kang
- Department of Biological Sciences, Ulsan National Institutes of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
- SmartinBio Inc., Cheongju 28160, Republic of Korea
| |
Collapse
|
2
|
Ye JQ, Xu SY, Liang Q, Dai YZ, He MY. Metal-Organic Frameworks-Derived Nanocarbon Materials and Nanometal Oxides for Photocatalytic Applications. Chem Asian J 2024; 19:e202400161. [PMID: 38500400 DOI: 10.1002/asia.202400161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 03/13/2024] [Accepted: 03/18/2024] [Indexed: 03/20/2024]
Abstract
Harnessing low-density solar energy and converting it into high-density chemical energy through photocatalysis has emerged as a promising avenue for the production of chemicals and remediation of environmental pollution, which contributes to alleviating the overreliance on fossil fuels. In recent years, metal-organic frameworks (MOFs) have gained widespread application in the field of photocatalysis due to their photostability, tunable structures, and responsiveness in the visible light range. However, most MOFs exhibit relatively low response to light, limiting their practical applications. MOFs-derived nanomaterials not only retain the inherent advantages of pristine MOFs but also show enhanced light adsorption and responsiveness. This review categorizes and summarizes MOFs-derived nanomaterials, including nanocarbons and nanometal oxides, providing representative examples for the synthetic strategies of each category. Subsequently, the recent research progress on MOFs-derived materials in photocatalytic applications are systematically introduced, specifically in the areas of photocatalytic water splitting to H2, photocatalytic CO2 reduction, and photocatalytic water treatment. The corresponding mechanisms involved in each photocatalytic reaction are elaborated in detail. Finally, the review discusses the challenges and further directions faced by MOFs-derived nanomaterials in the field of photocatalysis, highlighting their potential role in advancing sustainable energy production and environmental remediation.
Collapse
Affiliation(s)
- Jun-Qing Ye
- Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou, 213164, P. R. China
| | - Shu-Ying Xu
- Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou, 213164, P. R. China
| | - Qian Liang
- Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou, 213164, P. R. China
| | - Yan-Zi Dai
- Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou, 213164, P. R. China
| | - Ming-Yang He
- Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou, 213164, P. R. China
| |
Collapse
|
3
|
Kim Y, Nam D, Lee ES, Kim S, Cha BS, Park KS. Aptamer-Based Switching System for Communication of Non-Interacting Proteins. BIOSENSORS 2024; 14:47. [PMID: 38248424 PMCID: PMC10812979 DOI: 10.3390/bios14010047] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 01/09/2024] [Accepted: 01/10/2024] [Indexed: 01/23/2024]
Abstract
Biological macromolecules, such as DNA, RNA, and proteins in living organisms, form an intricate network that plays a key role in many biological processes. Many attempts have been made to build new networks by connecting non-communicable proteins with network mediators, especially using antibodies. In this study, we devised an aptamer-based switching system that enables communication between non-interacting proteins. As a proof of concept, two proteins, Cas13a and T7 RNA polymerase (T7 RNAP), were rationally connected using an aptamer that specifically binds to T7 RNAP. The proposed switching system can be modulated in both signal-on and signal-off manners and its responsiveness to the target activator can be controlled by adjusting the reaction time. This study paves the way for the expansion of biological networks by mediating interactions between proteins using aptamers.
Collapse
Affiliation(s)
| | | | | | | | | | - Ki Soo Park
- Department of Biological Engineering, College of Engineering, Konkuk University, Seoul 05029, Republic of Korea; (Y.K.); (D.N.); (E.S.L.); (S.K.); (B.S.C.)
| |
Collapse
|
4
|
Zheng X, Zhao Y, Zhang Y, Zhu Y, Zhang J, Xu D, Yang H, Zhou Y. Alkaline phosphatase triggered gold nanoclusters turn-on fluorescence immunoassay for detection of Ochratoxin A. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 304:123317. [PMID: 37688875 DOI: 10.1016/j.saa.2023.123317] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 08/28/2023] [Accepted: 08/30/2023] [Indexed: 09/11/2023]
Abstract
Ochratoxin A (OTA) is a highly toxic mycotoxin which can cause a variety of diseases. Sensitive detection of OTA is significant for food safety. Herein, a feasible and sensitive immunoassay was established for OTA detection by alkaline phosphatase (ALP) triggered gold nanoclusters (AuNCs) turn-on fluorescence. The fluorescence of the AuNCs can be quenched by Cr6+ induced aggregation of AuNCs and the fluorescence resonance energy transfer (FRET) between AuNCs and Cr6+. Under the catalytic action of ALP-labelled IgG (IgG-ALP), the ascorbic acid 2-phosphate (AA2P) was hydrolyzed to ascorbic acid (AA) for the reducing of Cr6+ to Cr3+. As a result, the degrees of AuNCs aggregation and FRET were weakened and the fluorescence of AuNCs was turned on. The amount of OTA in the sample was negatively correlated with the amount of IgG-ALP captured by anti-OTA monoclonal antibody (McAb) in the microplate. In optimal conditions, the turn-on fluorescence immunoassay had a good linear range of 6.25-100 ng/mL, and the detection limit was 0.693 ng/mL. The recoveries of OTA from corn were 95.89%-101.08% for the fluorescence immunoassay. This work provided a feasible, sensitive and good selectivity fluorescence method for OTA detection.
Collapse
Affiliation(s)
- Xiaolong Zheng
- College of Animal Science and Technology, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei, 434025, China
| | - Yanan Zhao
- College of Animal Science and Technology, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei, 434025, China
| | - Yan Zhang
- College of Life Science, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei, 434025, China
| | - Yuanhua Zhu
- College of Animal Science and Technology, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei, 434025, China
| | - Junxiang Zhang
- College of Life Science, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei, 434025, China
| | - Die Xu
- College of Life Science, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei, 434025, China
| | - Hualin Yang
- College of Animal Science and Technology, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei, 434025, China; College of Life Science, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei, 434025, China.
| | - Yu Zhou
- College of Animal Science and Technology, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei, 434025, China.
| |
Collapse
|
5
|
Berkal MA, Nardin C. Pesticide biosensors: trends and progresses. Anal Bioanal Chem 2023; 415:5899-5924. [PMID: 37668672 DOI: 10.1007/s00216-023-04911-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 08/08/2023] [Accepted: 08/10/2023] [Indexed: 09/06/2023]
Abstract
Pesticides, chemical substances extensively employed in agriculture to optimize crop yields, pose potential risks to human and environmental health. Consequently, regulatory frameworks are in place to restrict pesticide residue concentrations in water intended for human consumption. These regulations are implemented to safeguard consumer safety and mitigate any adverse effects on the environment and public health. Although gas chromatography- and liquid chromatography-mass spectrometry (GC-MS and LC-MS) are highly efficient techniques for pesticide quantification, their use is not suitable for real-time monitoring due to the need for sophisticated laboratory pretreatment of samples prior to analysis. Since they would enable analyte detection with selectivity and sensitivity without sample pretreatment, biosensors appear as a promising alternative. These consist of a bioreceptor allowing for specific recognition of the target and of a detection platform, which translates the biological interaction into a measurable signal. As early detection systems remain urgently needed to promptly alert and act in case of pollution, we review here the biosensors described in the literature for pesticide detection to advance their development for use in the field.
Collapse
Affiliation(s)
| | - Corinne Nardin
- Universite de Pau Et Des Pays de L'Adour, E2S UPPA, CNRS, IPREM, Pau, France.
| |
Collapse
|
6
|
Fan Y, Li J, Amin K, Yu H, Yang H, Guo Z, Liu J. Advances in aptamers, and application of mycotoxins detection: A review. Food Res Int 2023; 170:113022. [PMID: 37316026 DOI: 10.1016/j.foodres.2023.113022] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 05/16/2023] [Accepted: 05/19/2023] [Indexed: 06/16/2023]
Abstract
Mycotoxin contamination in food products can easily cause serious health hazards and economic losses to human beings. How to accurately detect and effectively control mycotoxin contamination has become a global concern. Mycotoxins conventional detection techniques e.g; ELISA, HPLC, have limitations like, low sensitivity, high cost and time-consuming. Aptamer-based biosensing technology has the advantages of high sensitivity, high specificity, wide linear range, high feasibility, and non-destructiveness, which overcomes the shortcomings of conventional analysis techniques. This review summarizes the sequences of mycotoxin aptamers that have been reported so far. Based on the application of four classic POST-SELEX strategies, it also discusses the bioinformatics-assisted POST-SELEX technology in obtaining optimal aptamers. Furthermore, trends in the study of aptamer sequences and their binding mechanisms to targets is also discussed. The latest examples of aptasensor detection of mycotoxins are classified and summarized in detail. Newly developed dual-signal detection, dual-channel detection, multi-target detection and some types of single-signal detection combined with unique strategies or novel materials in recent years are focused. Finally, the challenges and prospects of aptamer sensors in the detection of mycotoxins are discussed. The development of aptamer biosensing technology provides a new approach with multiple advantages for on-site detection of mycotoxins. Although aptamer biosensing shows great development potential, still some challenges and difficulties are there in practical applications. Future research need high focus on the practical applications of aptasensors and the development of convenient and highly automated aptamers. This may lead to the transition of aptamer biosensing technology from laboratory to commercialization.
Collapse
Affiliation(s)
- Yiting Fan
- College of Food Science and Engineering, Jilin Agricultural University, Changchun 130118, China; Division of Soybean Processing, Soybean Research & Development Center, Chinese Agricultural Research System, Changchun 130118, China.
| | - Jiaxin Li
- Division of Soybean Processing, Soybean Research & Development Center, Chinese Agricultural Research System, Changchun 130118, China; Universidade de Vigo, Nutrition and Bromatology Group, Department of Analytical and Food Chemistry, Faculty of Sciences, 32004 Ourense, Spain.
| | - Khalid Amin
- College of Food Science and Engineering, Jilin Agricultural University, Changchun 130118, China; Division of Soybean Processing, Soybean Research & Development Center, Chinese Agricultural Research System, Changchun 130118, China.
| | - Hansong Yu
- College of Food Science and Engineering, Jilin Agricultural University, Changchun 130118, China; Division of Soybean Processing, Soybean Research & Development Center, Chinese Agricultural Research System, Changchun 130118, China.
| | - Huanhuan Yang
- College of Food Science, Heilongjiang Bayi Agricultural University, Daqing 163000, China; College of Life Science Chang Chun Normal University, Changchun 130032, China.
| | - Zhijun Guo
- College of Agriculture, Yanbian University, Yanji 133002, China.
| | - Jingsheng Liu
- College of Food Science and Engineering, Jilin Agricultural University, Changchun 130118, China; National Engineering Laboratory for Wheat and Corn Deep Processing, Changchun, Jilin 130118, China.
| |
Collapse
|
7
|
Zhou J, Lv X, Gui Y, He J, Xie F, Cai J. Passion fruit-inspired dendritic mesoporous silica nanospheres-enriched quantum dots coupled with magnetism-controllable aptasensor enable sensitive detection of ochratoxin A in food products. Food Chem 2023; 425:136445. [PMID: 37270885 DOI: 10.1016/j.foodchem.2023.136445] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 04/29/2023] [Accepted: 05/20/2023] [Indexed: 06/06/2023]
Abstract
Ochratoxin A (OTA) is a powerful mycotoxin present in a variety of food products, and its detection is important for human health. Here, a fluorescent aptasensor is reported for sensitive OTA determination. Specifically, the surface of bio-inspired passion fruit-like dendritic mesoporous silica nanospheres-enriched quantum dots (MSNQs-apt) was first modified with the OTA aptamer as the recognition unit and fluorescence emitter, while the aptamer-complementary DNA (MNPs-cDNA) was linked with the magnetic nanoparticles (MNPs) as the separation element. In the range of 2.56 pg/mL to 8 ng/mL, the proposed aptasensor exhibited satisfactory linearity and a detection limit of 1.402 pg/mL. The developed aptasensor achieved recoveries of 90.98-103.20% and 94.33-107.57 % in red wine and wheat flour samples, respectively. By simply replacing the aptamer, this aptasensor can be easily extended to detection of other analytes, suggesting its potential as a universal detection platform for mycotoxins in food products.
Collapse
Affiliation(s)
- Jiaojiao Zhou
- National R&D Center for Se-rich Agricultural Products Processing, Hubei Engineering Research Center for Deep Processing of Green Se-rich Agricultural Products, School of Modern Industry for Selenium Science and Engineering, Wuhan Polytechnic University, Wuhan 430023, China
| | - Xuqin Lv
- National R&D Center for Se-rich Agricultural Products Processing, Hubei Engineering Research Center for Deep Processing of Green Se-rich Agricultural Products, School of Modern Industry for Selenium Science and Engineering, Wuhan Polytechnic University, Wuhan 430023, China; Key Laboratory for Deep Processing of Major Grain and Oil, Ministry of Education, Hubei Key Laboratory for Processing and Transformation of Agricultural Products, Wuhan Polytechnic University, Wuhan 430023, China
| | - Yue Gui
- National R&D Center for Se-rich Agricultural Products Processing, Hubei Engineering Research Center for Deep Processing of Green Se-rich Agricultural Products, School of Modern Industry for Selenium Science and Engineering, Wuhan Polytechnic University, Wuhan 430023, China
| | - Jiangling He
- National R&D Center for Se-rich Agricultural Products Processing, Hubei Engineering Research Center for Deep Processing of Green Se-rich Agricultural Products, School of Modern Industry for Selenium Science and Engineering, Wuhan Polytechnic University, Wuhan 430023, China
| | - Fang Xie
- National R&D Center for Se-rich Agricultural Products Processing, Hubei Engineering Research Center for Deep Processing of Green Se-rich Agricultural Products, School of Modern Industry for Selenium Science and Engineering, Wuhan Polytechnic University, Wuhan 430023, China
| | - Jie Cai
- National R&D Center for Se-rich Agricultural Products Processing, Hubei Engineering Research Center for Deep Processing of Green Se-rich Agricultural Products, School of Modern Industry for Selenium Science and Engineering, Wuhan Polytechnic University, Wuhan 430023, China; Key Laboratory for Deep Processing of Major Grain and Oil, Ministry of Education, Hubei Key Laboratory for Processing and Transformation of Agricultural Products, Wuhan Polytechnic University, Wuhan 430023, China.
| |
Collapse
|
8
|
Li J, Liu B, Liu L, Zhang N, Liao Y, Zhao C, Cao M, Zhong Y, Chai D, Chen X, Zhang D, Wang H, He Y, Li Z. Fluorescence-based aptasensors for small molecular food contaminants: From energy transfer to optical polarization. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 285:121872. [PMID: 36152504 DOI: 10.1016/j.saa.2022.121872] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 08/17/2022] [Accepted: 09/07/2022] [Indexed: 06/16/2023]
Abstract
Small molecular food contaminants, such as mycotoxins, pesticide residues and antibiotics, are highly probable to be passively introduced in food at all stages of its processing, including planting, harvest, production, transportation and storage. Owing to the high risks caused by the unknowing intake and accumulation in human, there is an urgent need to develop rapid, sensitive and efficient methods to monitor them. Fluorescence-based aptasensors provide a promising platform for this area owing to its simple operation, high sensitivity, wide application range and economical practicability. In this paper, the common sorts of small molecular contaminants in foods, namely mycotoxins, pesticides, antibiotics, etc, are briefly introduced. Then, we make a comprehensive review, from fluorescence resonance energy transfer (in turn-on, turn-off, and ratiometric mode, as well as energy upconversion) to fluorescence polarization, of the fluorescence-based aptasensors for the determination of these food contaminants reported in the last five years. The principle of signal generation, the advances of each sort of fluorescent aptasensors, as well as their applications are introduced in detail. Additionally, we also discussed the challenges and perspectives of the fluorescent aptasensors for small molecular food contaminants. This work will offer systematic overview and inspiration for amateurs, researchers and developers of fluorescence-based aptasensors for the detection of small molecules.
Collapse
Affiliation(s)
- Jingrong Li
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China
| | - Boshi Liu
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China; State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin 301617, China.
| | - Li Liu
- Library of Tianjin Medical University, Tianjin 300070, China
| | - Nan Zhang
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China
| | - Yumeng Liao
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China
| | - Chunyu Zhao
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China
| | - Manzhu Cao
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China
| | - Yuxuan Zhong
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China
| | - Danni Chai
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China
| | - Xiaoyu Chen
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China
| | - Di Zhang
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China; State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin 301617, China.
| | - Haixia Wang
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China; State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin 301617, China
| | - Yongzhi He
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China
| | - Zheng Li
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China; State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin 301617, China.
| |
Collapse
|
9
|
Yu H, Zhao Q. Aptamer Molecular Beacon Sensor for Rapid and Sensitive Detection of Ochratoxin A. Molecules 2022; 27:molecules27238267. [PMID: 36500359 PMCID: PMC9737911 DOI: 10.3390/molecules27238267] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 11/23/2022] [Accepted: 11/24/2022] [Indexed: 11/29/2022] Open
Abstract
Ochratoxin A (OTA) is a carcinogenic fungal secondary metabolite which causes wide contamination in a variety of food stuffs and environments and has a high risk to human health. Developing a rapid and sensitive method for OTA detection is highly demanded in food safety, environment monitoring, and quality control. Here, we report a simple molecular aptamer beacon (MAB) sensor for rapid OTA detection. The anti-OTA aptamer has a fluorescein (FAM) labeled at the 5' end and a black hole quencher (BHQ1) labeled at the 3' end. The specific binding of OTA induced a conformational transition of the aptamer from a random coil to a duplex-quadruplex structure, which brought FAM and BHQ1 into spatial proximity causing fluorescence quenching. Under the optimized conditions, this aptamer sensor enabled OTA detection in a wide dynamic concentration range from 3.9 nM to 500 nM, and the detection limit was about 3.9 nM OTA. This method was selective for OTA detection and allowed to detect OTA spiked in diluted liquor and corn flour extraction samples, showing the capability for OTA analysis in practical applications.
Collapse
Affiliation(s)
- Hao Yu
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Qiang Zhao
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
- University of Chinese Academy of Sciences, Beijing 100049, China
- School of Environment, Hangzhou Institute for Advanced Study, UCAS, Hangzhou 310024, China
- Correspondence:
| |
Collapse
|
10
|
Wang X, Liao X, Zhang B, Chen S, Zhang M, Mei L, Zhang L, Qiao X, Hong C. Fabrication of a novel electrochemical immunosensor for the sensitive detection of carcinoembryonic antigen using a double signal attenuation strategy. Anal Chim Acta 2022; 1232:340455. [DOI: 10.1016/j.aca.2022.340455] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Revised: 09/24/2022] [Accepted: 09/26/2022] [Indexed: 11/01/2022]
|
11
|
Jia W, Jin X, Wu Y, Xie D, Yin W, Zhao B, Huang Z, Liu L, Yang Y, Cao T, Feng X, Chang S. Amplification of fluorescence polarization signal based on specific recognition of aptamers combined with quantum quenching effect for ultrasensitive and simple detection of PCB-77. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 278:121341. [PMID: 35550993 DOI: 10.1016/j.saa.2022.121341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 04/19/2022] [Accepted: 04/30/2022] [Indexed: 06/15/2023]
Abstract
Here, we report a novel aptasensor based on decahedral silver nanoparticles (Ag10NPs) enhanced fluorescence polarization (FP) for detecting PCB-77. Using aptamer modified Ag10NPs hybridized with DNA sequence labeled fluorescent group as an analytical probe, polychlorinated biphenyls (PCB-77) could be detected with high sensitivity and selectivity. The linear range of determination was 0.02 ng/L to 390 ng/L and the limit of detection was 5 pg/L. In addition, through the optimization of the experiment condition and signal probe DNA (pDNA), we found that the maximum FP signal could be generated when the distance between fluorescein and the surface of Ag10NPs was 3 nm. When the aptamer was immobilized on the surface of Ag10NPs could be strengthened the anti-interference performance of aptamer nanoprobe and further improved the detection ability. At the same time, we also compared the detection performance of the traditional FP signal enhancer streptavidin (SA) analysis system. The fluorescence polarization aptasensor could detect PCB-77 samples efficiently in complex environmental water, which shows a good application prospect.
Collapse
Affiliation(s)
- Wenchao Jia
- South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; State Environmental Protection Key Laboratory of Environmental Pollution Health Risk Assessment, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China.
| | - Xiangying Jin
- South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; State Environmental Protection Key Laboratory of Environmental Pollution Health Risk Assessment, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China
| | - Yuhua Wu
- Zhongkai University of Agriculture and Engineering, Guangzhou 510225, China
| | - Danping Xie
- South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; State Environmental Protection Key Laboratory of Environmental Pollution Health Risk Assessment, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China.
| | - Wenhua Yin
- South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; State Environmental Protection Key Laboratory of Environmental Pollution Health Risk Assessment, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China
| | - Bo Zhao
- South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; State Environmental Protection Key Laboratory of Environmental Pollution Health Risk Assessment, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China
| | - Zhonghui Huang
- South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; State Environmental Protection Key Laboratory of Environmental Pollution Health Risk Assessment, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China
| | - Lijun Liu
- South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; State Environmental Protection Key Laboratory of Environmental Pollution Health Risk Assessment, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China
| | - Yanyan Yang
- South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; State Environmental Protection Key Laboratory of Environmental Pollution Health Risk Assessment, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China
| | - Tonghui Cao
- South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China; State Environmental Protection Key Laboratory of Environmental Pollution Health Risk Assessment, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China
| | - Xidan Feng
- Zhongkai University of Agriculture and Engineering, Guangzhou 510225, China
| | - Sheng Chang
- National Engineering Laboratory for Lake Pollution Control and Ecological Restoration, State Environmental Protection Key Laboratory of Drinking Water Source Protection, Chinese Research Academy of Environmental Sciences, Beijing 100012, China.
| |
Collapse
|
12
|
Hao L, Li M, Peng K, Ye T, Wu X, Yuan M, Cao H, Yin F, Gu H, Xu F. Fluorescence Resonance Energy Transfer Aptasensor of Ochratoxin A Constructed Based on Gold Nanorods and DNA Tetrahedrons. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2022; 70:10662-10668. [PMID: 35939804 DOI: 10.1021/acs.jafc.2c03626] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Ochratoxin A (OTA) contamination of corn has received significant attention due to the wide distribution and high toxicity of OTA. The maximum residue limit standard of OTA in corn has been established by the Chinese Government and other unions. Nanoparticle-based fluorescence resonance energy transfer (FRET) assays are promising methods for the sensitive and fast detection of OTA. However, satisfactory detection sensitivity is commonly achieved with complicated signal amplification processes or specific nanoparticle morphologies, which means that these assays are not conducive to fast detection. This study proposes a simple and novel strategy to improve the sensitivity of FRET aptasensors. In this strategy, a DNA tetrahedron was first used in gold nanorod-based FRET aptasensors. DNA tetrahedron-modified gold nanorods are used as fluorescent acceptors, and Cy5-modified complementary sequences of the OTA aptamer are used as fluorescent donors. The aptamers of OTA are embedded in the DNA tetrahedrons, and FRET occurs when the aptamers hybridize with the Cy5-modified complementary sequences. The aptamer-integrated DNA tetrahedron modified on the surface of gold nanorods acts as an anchor, thus avoiding the crowding and entanglement of aptamers. Due to the competitive combination between the OTA aptamers and complementary sequences, the greater the amount of OTA, the less the amount of Cy5-modified complementary sequences that bind with the aptamers and the less the amount of Cy5 that is quenched. Thus, the fluorescence intensity is positively related to the OTA concentration. In this study, in the concentration range of 0.01-10 ng/mL, the fluorescence intensity was found to be linearly related to the logarithmic concentration of OTA. The limit of detection was calculated to be 0.005 ng/mL. The specificity of the developed biosensor was demonstrated to be efficient. The accuracy and stability of the developed aptasensor were also tested, and the method exhibited good performance in real samples.
Collapse
Affiliation(s)
- Liling Hao
- School of Health Science and Engineering, Shanghai Engineering Research Center for Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Mengqiu Li
- School of Health Science and Engineering, Shanghai Engineering Research Center for Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Kaimin Peng
- School of Health Science and Engineering, Shanghai Engineering Research Center for Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Tai Ye
- School of Health Science and Engineering, Shanghai Engineering Research Center for Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Xiuxiu Wu
- School of Health Science and Engineering, Shanghai Engineering Research Center for Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Min Yuan
- School of Health Science and Engineering, Shanghai Engineering Research Center for Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Hui Cao
- School of Health Science and Engineering, Shanghai Engineering Research Center for Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Fengqin Yin
- School of Health Science and Engineering, Shanghai Engineering Research Center for Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Huajie Gu
- School of Chemistry and Life Sciences, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Fei Xu
- School of Health Science and Engineering, Shanghai Engineering Research Center for Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai 200093, China
| |
Collapse
|
13
|
Ma P, Duan N, Ye H, Xia Y, Ding Z, Wang Z. Selection, truncation and fluorescence polarization based aptasensor for Weissella viridescens detection. Talanta 2022; 246:123499. [PMID: 35594734 DOI: 10.1016/j.talanta.2022.123499] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 03/27/2022] [Accepted: 04/19/2022] [Indexed: 01/09/2023]
Abstract
Weissella viridescens is a spoilage bacterium commonly found in low-temperature meat products. In this work, after fifteen rounds including three counter selection rounds of whole-cell systemic evolution of ligands by exponential enrichment (SELEX) in vitro, a novel aptamer L3 that can specifically recognize W. viridescens was obtained with a dissociation constant (Kd) value of 68.25 ± 5.32 nM. The sequence of aptamer L3 was optimized by truncation and a new aptamer sequence TL43 was obtained with a lower Kd value of 32.11 ± 3.01 nM. Finally, a simple and rapid fluorescence polarization (FP) platform was constructed to detect W. viridescens, in which FAM-labeled complementary sequence (FAM-cDNA) was employed to generate FP signal and streptavidin was used to amplify FP signal. In the presence of target bacteria, FP value decreased owning to the dissociation of FAM-cDNA from streptavidin/biotin-TL43/FAM-cDNA complex. Under optimal conditions, the concentration of W. viridescens and FP value displayed a good linear relationship with the detection range from 102 to 106 cfu/mL. Moreover, the designed detection system had a good recovery rate of 90.6%-107.7% in smoked ham samples compared with classical plate counting method, indicating the great potential of the selected and truncated aptamer in practical biosensing applications.
Collapse
Affiliation(s)
- Pengfei Ma
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology Jiangnan University, Wuxi, 214122, China; National Engineering Research Center for Functional Food, Jiangnan University, Wuxi, 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, 214122, China
| | - Nuo Duan
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology Jiangnan University, Wuxi, 214122, China; National Engineering Research Center for Functional Food, Jiangnan University, Wuxi, 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, 214122, China
| | - Hua Ye
- School of Grain Science and Technology, Jiangsu University of Science and Technology, Zhenjiang, 212100, China
| | - Yu Xia
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology Jiangnan University, Wuxi, 214122, China; National Engineering Research Center for Functional Food, Jiangnan University, Wuxi, 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, 214122, China
| | - Zhongyang Ding
- Key Laboratory of Carbohydrate Chemistry and Biotechnology, Ministry of Education, School of Biotechnology, Jiangnan University, Wuxi, 214122, China.
| | - Zhouping Wang
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology Jiangnan University, Wuxi, 214122, China; National Engineering Research Center for Functional Food, Jiangnan University, Wuxi, 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, 214122, China.
| |
Collapse
|
14
|
Yan X, Chen H, Du G, Guo Q, Yuan Y, Yue T. Recent trends in fluorescent aptasensors for mycotoxin detection in food: Principles, constituted elements, types, and applications. FOOD FRONTIERS 2022. [DOI: 10.1002/fft2.144] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Affiliation(s)
- Xiaohai Yan
- College of Food Science and Engineering Northwest A&F University Yangling 712100 China
- Laboratory of Quality and Safety Risk Assessment for Agro‐products (Yangling) Ministry of Agriculture Yangling 712100 China
| | - Hong Chen
- College of Food Science and Engineering Northwest A&F University Yangling 712100 China
- Laboratory of Quality and Safety Risk Assessment for Agro‐products (Yangling) Ministry of Agriculture Yangling 712100 China
| | - Gengan Du
- College of Food Science and Engineering Northwest A&F University Yangling 712100 China
- Laboratory of Quality and Safety Risk Assessment for Agro‐products (Yangling) Ministry of Agriculture Yangling 712100 China
| | - Qi Guo
- College of Food Science and Engineering Northwest A&F University Yangling 712100 China
- Laboratory of Quality and Safety Risk Assessment for Agro‐products (Yangling) Ministry of Agriculture Yangling 712100 China
| | - Yahong Yuan
- College of Food Science and Engineering Northwest A&F University Yangling 712100 China
- Laboratory of Quality and Safety Risk Assessment for Agro‐products (Yangling) Ministry of Agriculture Yangling 712100 China
| | - Tianli Yue
- College of Food Science and Engineering Northwest A&F University Yangling 712100 China
- Laboratory of Quality and Safety Risk Assessment for Agro‐products (Yangling) Ministry of Agriculture Yangling 712100 China
- College of Food Science and Technology Northwest University Xi’ an 710000 China
| |
Collapse
|
15
|
Xiao X, Zhen S. Recent advances in fluorescence anisotropy/polarization signal amplification. RSC Adv 2022; 12:6364-6376. [PMID: 35424604 PMCID: PMC8982260 DOI: 10.1039/d2ra00058j] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 02/16/2022] [Indexed: 12/25/2022] Open
Abstract
Fluorescence anisotropy/polarization is an attractive and versatile technique based on molecular rotation in biochemical/biophysical systems. Traditional fluorescence anisotropy/polarization assays showed relatively low sensitivity for molecule detection, because widespread molecular masses are too small to produce detectable changes in fluorescence anisotropy/polarization value. In this review, we discuss in detail how the potential of fluorescence anisotropy/polarization signal approach considerably expanded through the implementation of mass amplification, recycle the target amplification, fluorescence probes structure-switching amplification, resonance energy transfer amplification, and provide perspectives at future directions and applications.
Collapse
Affiliation(s)
- Xue Xiao
- Key Laboratory of Basic Chemistry of the State Ethnic Commission, College of Chemistry and Environment, Southwest Minzu University 610041 Chengdu PR China
| | - Shujun Zhen
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University 400715 Chongqing PR China
| |
Collapse
|
16
|
Yan X, Shu Q, Zhao K, Xiao Y, Ai F, Zheng X. Chemiluminescence "signal-on-off" dual signals ratio biosensor based on single-stranded DNA functions as guy wires to detect EcoR V. Talanta 2021; 235:122749. [PMID: 34517617 DOI: 10.1016/j.talanta.2021.122749] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Revised: 07/25/2021] [Accepted: 07/27/2021] [Indexed: 11/29/2022]
Abstract
Signal output mode is the important part of biosensor. In general, "signal on" and "signal off" are two common output modes. The development of dual signals-based ratio analysis as a powerful diagnostic tool has attracted widespread attention in the biosensor field in recent years. Dual signals ratio sensors with "signal on" and "signal off" are more favored because of their low background signal and better sensitivity and selectivity. In this study, inspired by the idea that EcoR V can cut specific sites of DNA to produce two corresponding fragments, and by using the capturing probe as guy wires, a reliable and sensitive method for EcoR V assay is developed based on the ratio of dual chemiluminescence (CL) signals for the first time. In particular, in the existence of the objective EcoR V, the substrate DNA would be degraded into two double stranded oligonucleotides with blunt ends which include the sequence I and the sequence II, then they can separately compete with two different corresponding capture probes on magnetic beads (MBs). One of capture probe hybridized with the sequence I containing more guanine (G) bases that reacted with the phenylglyoxal (PG) to produce chemical reaction which triggered a positive CL signal output I + CL as "signal-on"; another capture probe is priority to hybridize the sequence II, which triggered the weaker reporter DNA linked with horseradish peroxidase (HRP) probe to fall off the MBs, thereby outputting a negative CL signal I-CL as "signal-off". By comparing the linear relation and the correlation coefficient, the I-CL/I + CL ratio method has better linear relation (0.01-10 U/mL) and higher sensitivity (0.0045 U/mL). In addition, this developed strategy of high selectivity which can directly detect low concentration of target EcoR V in human serum, and thus this dual ratio biosensor might offer a promising detection approach for clinical diagnostics.
Collapse
Affiliation(s)
- Xiluan Yan
- School of Resources, Environmental, and Chemical Engineering, Nanchang University, Nanchang, 330031, China
| | - Qinglei Shu
- School of Resources, Environmental, and Chemical Engineering, Nanchang University, Nanchang, 330031, China
| | - Kun Zhao
- School of Resources, Environmental, and Chemical Engineering, Nanchang University, Nanchang, 330031, China
| | - Yipi Xiao
- Department of Orthopedics, Hongdu Traditional Chinese Medicine Hospital, Nanchang, 330031, China
| | - Fanrong Ai
- School of Mechanical and Electrical Engineering, Nanchang University, Nanchang, 330031, China
| | - Xiangjuan Zheng
- College of Chemistry, Nanchang University, Nanchang, 330031, China.
| |
Collapse
|
17
|
YANG C, DONG SN, ABBAS F, CHU XL, FAN AQ, RHOUATI A, MAO J, LIU Y. Label-free fluorescence aptasensor for ochratoxin A using crystal violet as displacement-type probe. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2021. [DOI: 10.1016/j.cjac.2021.07.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
18
|
Ma P, Guo H, Duan N, Ma X, Yue L, Gu Q, Wang Z. Label free structure-switching fluorescence polarization detection of chloramphenicol with truncated aptamer. Talanta 2021; 230:122349. [PMID: 33934798 DOI: 10.1016/j.talanta.2021.122349] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Revised: 03/02/2021] [Accepted: 03/18/2021] [Indexed: 12/18/2022]
Abstract
In this study, the original chloramphenicol aptamer containing 80 bases was truncated to 30 bases with high affinity by the SYBR Green I assay. It was found that the ionic strength and type affect the recognition of aptamers, especially magnesium ion played a vital role in the binding process. Furthermore, the binding performance of aptamer, including binding mode, key binding sites and conformational changes were further investigated by circular dichroism spectroscopy, UV-vis absorption spectrum and molecular docking. Based on these research data, we inferred that chloramphenicol bound to the minor groove region in the aptamer double helix. Finally, the optimized aptamer LLR10 was used to develop a novel label free fluorescence polarization assay to detect chloramphenicol within SYBR Green I as the source of fluorescence polarization signal. Under optimal conditions, the designed method showed a linear detection range of 0.1-10 nM with a detection limit of 0.06 nM. Additionally, the aptasensor exhibited a high accuracy to the detection of chloramphenicol in milk samples with a recovery rate from 93.7% to 98.4%. Therefore, the developed label free fluorescence polarization aptasensor provides a new idea for the rapid, reliable and sensitive detection of chloramphenicol, which can be applied to food safety control.
Collapse
Affiliation(s)
- Pengfei Ma
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, 214122, China
| | - Hualin Guo
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, 214122, China
| | - Nuo Duan
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, 214122, China
| | - Xiaoyuan Ma
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, 214122, China
| | - Lin Yue
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, 214122, China
| | - Qianhui Gu
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; Three Squirrels Inc., Wuhu, 241000, China
| | - Zhouping Wang
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; National Engineering Research Center for Functional Food, Jiangnan University, Wuxi, Jiangsu, 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, 214122, China; Collaborative Innovation Center of Food Safety and Quality Control of Jiangsu Province, Jiangnan University, Wuxi, 214122, China.
| |
Collapse
|
19
|
Li Y, Zhao Q. Antibody- and aptamer-based competitive fluorescence polarization/anisotropy assays for ochratoxin A with tetramethylrhodamine-labeled ochratoxin A. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:1612-1617. [PMID: 33734257 DOI: 10.1039/d1ay00003a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Ochratoxin A (OTA) is one of the mycotoxins that often contaminate a variety of food stuffs, and it is a potential carcinogen for humans. Taking advantage of selective affinity binding and simple, rapid, and sensitive fluorescence polarization (FP)/fluorescence anisotropy (FA) analysis, here, we report two competitive FP/FA assays for OTA using tetramethylrhodamine (TMR)-labeled OTA as a fluorescence tracer and either antibody or aptamer as an affinity ligand to recognize OTA. In the absence of OTA, the TMR-labeled OTA binds with a large-sized affinity ligand, showing a high FA value due to the slow rotation of the affinity complex. When OTA is present, OTA competes with the TMR-labeled OTA tracer in binding limited amount of affinity ligand, causing more free TMR-labeled OTA and a significant FA decrease. We found that the antibody showed a stronger affinity towards TMR-labeled OTA compared to the aptamer. The antibody-based FA assay showed higher signal changes than the aptamer based FA assay due to the larger size of antibody over aptamer. The antibody-based competitive FA assay enabled the detection of 2.4 nM OTA, while the aptamer-based FA assay also achieved a detection limit of 2.4 nM OTA at 10 °C with the help of streptavidin conjugation to increase the molecular size and to improve aptamer affinity. These two competitive FA assays were selective, showing capability for analysis in diluted red wine.
Collapse
Affiliation(s)
- Yapiao Li
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.
| | | |
Collapse
|
20
|
Hendrickson OD, Taranova NA, Zherdev AV, Dzantiev BB, Eremin SA. Fluorescence Polarization-Based Bioassays: New Horizons. SENSORS (BASEL, SWITZERLAND) 2020; 20:E7132. [PMID: 33322750 PMCID: PMC7764623 DOI: 10.3390/s20247132] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Revised: 12/07/2020] [Accepted: 12/09/2020] [Indexed: 02/06/2023]
Abstract
Fluorescence polarization holds considerable promise for bioanalytical systems because it allows the detection of selective interactions in real time and a choice of fluorophores, the detection of which the biosample matrix does not influence; thus, their choice simplifies and accelerates the preparation of samples. For decades, these possibilities were successfully applied in fluorescence polarization immunoassays based on differences in the polarization of fluorophore emissions excited by plane-polarized light, whether in a free state or as part of an immune complex. However, the results of recent studies demonstrate the efficacy of fluorescence polarization as a detected signal in many bioanalytical methods. This review summarizes and comparatively characterizes these developments. It considers the integration of fluorescence polarization with the use of alternative receptor molecules and various fluorophores; different schemes for the formation of detectable complexes and the amplification of the signals generated by them. New techniques for the detection of metal ions, nucleic acids, and enzymatic reactions based on fluorescence polarization are also considered.
Collapse
Affiliation(s)
- Olga D. Hendrickson
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (O.D.H.); (N.A.T.); (B.B.D.); (S.A.E.)
| | - Nadezhda A. Taranova
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (O.D.H.); (N.A.T.); (B.B.D.); (S.A.E.)
| | - Anatoly V. Zherdev
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (O.D.H.); (N.A.T.); (B.B.D.); (S.A.E.)
| | - Boris B. Dzantiev
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (O.D.H.); (N.A.T.); (B.B.D.); (S.A.E.)
| | - Sergei A. Eremin
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (O.D.H.); (N.A.T.); (B.B.D.); (S.A.E.)
- Department of Chemical Enzymology, Chemical Faculty, M.V. Lomonosov Moscow State University, 119234 Moscow, Russia
| |
Collapse
|
21
|
Aptamer binding assays and molecular interaction studies using fluorescence anisotropy - A review. Anal Chim Acta 2020; 1125:267-278. [PMID: 32674773 DOI: 10.1016/j.aca.2020.05.061] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 05/16/2020] [Accepted: 05/23/2020] [Indexed: 12/26/2022]
Abstract
Binding of nucleic acid aptamers to specific targets and detection with fluorescence anisotropy (FA) or fluorescence polarization (FP) take advantage of the complementary features of aptamers and the fluorescence techniques. We review recent advances in affinity binding assays using aptamers and FA/FP, with an emphasis on studies of molecular interactions and identification of binding sites. Aptamers provide several benefits, including the ease of labelling fluorophores on specific sites, binding-induced changes in aptamer structures, hybridization of the aptamers to complementary sequences, changes in molecular volume upon binding of the aptamer to its target, and adsorption of aptamers onto nanomaterials. Some of these benefits have been utilized for FA/FP assays. Once the aptamer binds to its target, the resulting changes in molecular volume (size), structure, local rotation of the fluorophore, and/or the fluorescence lifetime influence changes to the FA/FP values. Measurements of these fluorescence anisotropy/polarization changes have provided insights into the molecular interactions, such as the binding affinity and the site of binding. Studies of molecular interactions conducted in homogeneous solutions, as well as those with separations, e.g., capillary electrophoresis, have been summarized in this review. Studies on mapping the position of binding in aptamers at the single nucleotide level have demonstrated a unique benefit of the FA/FP techniques and pointed to an exciting direction for future research.
Collapse
|