1
|
Yue H, He F, Zhao Z, Duan Y. Plasma-based ambient mass spectrometry: Recent progress and applications. MASS SPECTROMETRY REVIEWS 2023; 42:95-130. [PMID: 34128567 DOI: 10.1002/mas.21712] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Revised: 05/28/2020] [Accepted: 06/02/2020] [Indexed: 06/12/2023]
Abstract
Ambient mass spectrometry (AMS) has grown as a group of advanced analytical techniques that allow for the direct sampling and ionization of the analytes in different statuses from their native environment without or with minimum sample pretreatments. As a significant category of AMS, plasma-based AMS has gained a lot of attention due to its features that allow rapid, real-time, high-throughput, in vivo, and in situ analysis in various fields, including bioanalysis, pharmaceuticals, forensics, food safety, and mass spectrometry imaging. Tens of new methods have been developed since the introduction of the first plasma-based AMS technique direct analysis in real-time. This review first provides a comprehensive overview of the established plasma-based AMS techniques from their ion source configurations, mechanisms, and developments. Then, the progress of the representative applications in various scientific fields in the past 4 years (January 2017 to January 2021) has been summarized. Finally, we discuss the current challenges and propose the future directions of plasma-based AMS from our perspective.
Collapse
Affiliation(s)
- Hanlu Yue
- College of Life Sciences, Sichuan University, Chengdu, China
| | - Feiyao He
- College of Life Sciences, Sichuan University, Chengdu, China
| | - Zhongjun Zhao
- School of Chemical Engineering, Sichuan University, Chengdu, China
| | - Yixiang Duan
- College of Life Sciences, Sichuan University, Chengdu, China
- School of Manufacturing Science and Engineering, Sichuan University, Chengdu, China
| |
Collapse
|
2
|
Jang M, Yang H, Shin G, Koo JM, Hwang SY, Park J, X. Oh D. Determination of Methanol in Commercialized Alcohol-based Hand Sanitizing and Other Similar Products using Headspace GC-MS. CURR ANAL CHEM 2022. [DOI: 10.2174/1573411018666220107145321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
Demand for alcohol-based products, including gel- and aqueous-type hand sanitizers, room sprays, and mouthwashes, has sharply increased during the ongoing COVID-19 pandemic because of their microbicidal properties. However, toxic methanol can be found from intentional addition of methanol by manufacturers and invariable production during the manufacture alcohol (ethanol). Although the FDA has recommended that such products should contain less than 630 ppm of methanol, it is only a temporary measure established specifically to regulate such products during the current COVID-19 pandemic and hence is not strictly regulated.
Objective:
This study aims to detect and quantify the level of methanol in alcohol-based products. However, some manufacturers unethically add methanol in their products and promote them as methanol-free. Besides, they do not provide proficiency and toxicity test results. Therefore, these kinds of products need to be analyzed to determine if they are acceptable to use.
Method:
This study qualitatively and quantitatively investigates the amount of methanol in commercial alcohol-based products using a newly developed headspace gas chromatography/mass spectrometry method. Moreover, alcohol beverages which contain methanol were analyzed to be compared with the levels of methanol in alcohol-based products and determine if their methanol levels are acceptable.
Results:
Methanol concentrations in gel-type hand sanitizers (517 ppm) and mouthwashes (202 ppm) were similar to those in white wine (429 ppm) and beer (256 ppm), respectively, while that of aqueous-type hand sanitizers (1139 ppm) is 1.5 times more than that of red wine (751 ppm).
Conclusion:
Methanol levels in most of the alcohol-based products did not exceed the FDA-recommended limit.
Collapse
Affiliation(s)
- Min Jang
- Research Center for Bio-Based Chemistry, Korea Research Institute of Chemical Technology (KRICT), Ulsan 44425, Republic of Korea
| | - Hyemin Yang
- Research Center for Bio-Based Chemistry, Korea Research Institute of Chemical Technology (KRICT), Ulsan 44425, Republic of Korea
| | - Giyoung Shin
- Research Center for Bio-Based Chemistry, Korea Research Institute of Chemical Technology (KRICT), Ulsan 44425, Republic of Korea
| | - Jun Mo Koo
- Research Center for Bio-Based Chemistry, Korea Research Institute of Chemical Technology (KRICT), Ulsan 44425, Republic of Korea
| | - Sung Yeon Hwang
- Research Center for Bio-Based Chemistry, Korea Research Institute of Chemical Technology (KRICT), Ulsan 44425, Republic of Korea
| | - Jeyoung Park
- Research Center for Bio-Based Chemistry, Korea Research Institute of Chemical Technology (KRICT), Ulsan 44425, Republic of Korea
| | - Dongyeop X. Oh
- Research Center for Bio-Based Chemistry, Korea Research Institute of Chemical Technology (KRICT), Ulsan 44425, Republic of Korea
| |
Collapse
|
3
|
Zeinali S, Pawliszyn J. Determination of Droplet-Bound and Free Gas-Phase Fragrances Using a Filter-Incorporated Needle-Trap Device and Solid-Phase Microextraction Technologies. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2021; 69:13657-13667. [PMID: 34662115 DOI: 10.1021/acs.jafc.1c06006] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Some of the fragrance compounds in aerosols tend to remain trapped inside the droplets. The ability to capture these droplets would make it possible to desorb and transfer the analytes dissolved within for determination. In this study, we design a novel filter-incorporated needle-trap device and use it to capture fragrance compounds in droplets as well as the gas phase of seven aerosol spray samples. For comparison, thin-film and solid-phase microextraction were also employed to extract gas-phase-borne fragrances from the same sprays. The results revealed that the filter-incorporated needle-trap device enables the extraction of total concentrations due to its ability to trap fragrance-containing droplets, whereas thin-film and solid-phase microextraction are only able to extract unbound compounds present in the gas phase. In addition, the developed needle-trap device provided acceptable results, proving its applicability for the analysis of aroma in other samples, such as beer and soda.
Collapse
Affiliation(s)
- Shakiba Zeinali
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
4
|
Rafson JP, Sacks GL. Rapid Analysis of Volatile Phenols from Grape Juice by Immersive Sorbent Sheet Extraction Prior to Direct Analysis in Real-Time Mass Spectrometry (DART-MS). JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2021; 69:12344-12353. [PMID: 34618472 DOI: 10.1021/acs.jafc.1c04197] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Poly(dimethylsiloxane)-based thin-film sorbent sheets (SPMESH) have previously been used for parallel headspace (HS) extraction prior to direct analysis in real-time mass spectrometry (DART-MS) for rapid quantitation of odorants in complex matrices. However, HS-SPMESH extraction is poorly suited for less volatile odorants, e.g., volatile phenols. This report describes modifications to the previous SPMESH extraction device, which make it amenable to parallel extraction of low-volatility analytes from multiwell plates under direct immersion (DI) conditions. Optimization and validation of the DI-SPMESH-DART-MS approach were performed on four volatile phenols (4-ethylphenol, 4-ethylguaiacol, 4-methylguaiacol, and guaiacol) of relevance to the quality of grape juices. Negative-ion mode DART-MS spectra showed a series of oxygenated adducts [M + nO - H]- for all analytes, but isobaric interferences could be limited for three of the four analytes by selecting an appropriate MS/MS transition. Signal suppression from nonvolatiles (sugars, acids) could be overcome by a rinse step. DI-SPMESH-DART-MS analysis of 24 samples could be performed in ∼45 min (30 min extraction, 16 min DART analysis) with 0.5-3 μg/L detection limits in aqueous and model juice solutions. In real grape juices (n = 5 cultivars), good accuracy (72-137%) could be achieved for two of the four volatile phenols initially investigated, 4-ethylphenol and 4-ethylguaiacol. However, poor accuracy was observed for guaiacol in some cultivars, and 4-methylguaiacol could not be quantitated due to interferences with other volatile phenols. Despite these limitations, DI-SPMESH-DART-MS/MS may be useful for prescreening a large number of samples prior to more selective conventional analyses.
Collapse
Affiliation(s)
- Jessica P Rafson
- Department of Food Science, Cornell University, Stocking Hall, Ithaca, New York 14853, United States
| | - Gavin L Sacks
- Department of Food Science, Cornell University, Stocking Hall, Ithaca, New York 14853, United States
| |
Collapse
|
5
|
Echeverri SA, Miller AE, Chen J, McQueen EW, Plakke M, Spicer M, Hoke KL, Stoddard MC, Morehouse NI. How signaling geometry shapes the efficacy and evolution of animal communication systems. Integr Comp Biol 2021; 61:787-813. [PMID: 34021338 DOI: 10.1093/icb/icab090] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
Animal communication is inherently spatial. Both signal transmission and signal reception have spatial biases-involving direction, distance and position-that interact to determine signaling efficacy. Signals, be they visual, acoustic, or chemical, are often highly directional. Likewise, receivers may only be able to detect signals if they arrive from certain directions. Alignment between these directional biases is therefore critical for effective communication, with even slight misalignments disrupting perception of signaled information. In addition, signals often degrade as they travel from signaler to receiver, and environmental conditions that impact transmission can vary over even small spatiotemporal scales. Thus, how animals position themselves during communication is likely to be under strong selection. Despite this, our knowledge regarding the spatial arrangements of signalers and receivers during communication remains surprisingly coarse for most systems. We know even less about how signaler and receiver behaviors contribute to effective signaling alignment over time, or how signals themselves may have evolved to influence and/or respond to these aspects of animal communication. Here, we first describe why researchers should adopt a more explicitly geometric view of animal signaling, including issues of location, direction, and distance. We then describe how environmental and social influences introduce further complexities to the geometry of signaling. We discuss how multimodality offers new challenges and opportunities for signalers and receivers. We conclude with recommendations and future directions made visible by attention to the geometry of signaling.
Collapse
Affiliation(s)
| | - Audrey E Miller
- Department of Ecology and Evolutionary Biology, Princeton University, Princeton, NJ
| | - Jason Chen
- Department of Biological Sciences, University of Pittsburgh, Pittsburgh, PA.,Department of Biology, Emory University, Atlanta, GA
| | - Eden W McQueen
- Department of Biological Sciences, University of Pittsburgh, Pittsburgh, PA
| | - Melissa Plakke
- Department of Biological Sciences, University of Pittsburgh, Pittsburgh, PA.,Department of Ecology and Evolutionary Biology, University of Kansas, Lawrence, KS
| | - Michelle Spicer
- Department of Biological Sciences, University of Pittsburgh, Pittsburgh, PA.,Biology Department, University of Puget Sound, Tacoma, WA
| | - Kim L Hoke
- Department of Biology, Colorado State University, Fort Collins, CO
| | | | - Nathan I Morehouse
- Department of Biological Sciences, University of Pittsburgh, Pittsburgh, PA.,Department of Biological Sciences, University of Cincinnati, Cincinnati, OH
| |
Collapse
|
6
|
Gionfriddo E, Gómez-Ríos GA. Analysis of food samples made easy by microextraction technologies directly coupled to mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2021; 56:e4665. [PMID: 33098354 DOI: 10.1002/jms.4665] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2020] [Revised: 09/18/2020] [Accepted: 09/25/2020] [Indexed: 06/11/2023]
Abstract
Because of the complexity and diversity of food matrices, their chemical analysis often entails several analytical challenges to attain accurate and reliable results, especially for multiresidue analysis and ultratrace quantification. Nonetheless, microextraction technology, such as solid-phase microextraction (SPME), has revolutionized the concept of sample preparation for complex matrices because of its nonexhaustive, yet quantitative extraction approach and its amenability to coupling to multiple analytical platforms. In recent years, microextraction devices directly interfaced with mass spectrometry (MS) have redefined the analytical workflow by providing faster screening and quantitative methods for complex matrices. This review will discuss the latest developments in the field of food analysis by means of microextraction approaches directly coupled to MS. One key feature that differentiates SPME-MS approaches from other ambient MS techniques is the use of matrix compatible extraction phases that prevent biofouling, which could drastically affect the ionization process and are still capable of selective extraction of the targeted analytes from the food matrix. Furthermore, the review examines the most significant applications of SPME-MS for various ionization techniques such as direct analysis in real time, dielectric barrier desorption ionization, and some unique SPME geometries, for example, transmission mode SPME and coated blade spray, that facilitate the interface to MS instrumentation.
Collapse
Affiliation(s)
- Emanuela Gionfriddo
- Department of Chemistry and Biochemistry, College of Natural Sciences and Mathematics, The University of Toledo, Toledo, Ohio, 43606, USA
- School of Green Chemistry and Engineering, The University of Toledo, Toledo, Ohio, 43606, USA
- Dr. Nina McClelland Laboratory for Water Chemistry and Environmental Analysis, The University of Toledo, Toledo, Ohio, 43606, USA
| | | |
Collapse
|
7
|
Abstract
Thirty years since the invention and public disclosure of solid phase microextraction (SPME), the technology continues evolving and inspiring several other green extraction technologies amenable for the collection of small molecules present in complex matrices. In this manuscript, we review the fundamental and operational aspects of a novel SPME geometry that can be used to “hunt” target molecules in complex matrices: the SPME Arrow. In addition, a series of applications in environmental, food, cannabis and forensic analysis are succinctly covered. Finally, special emphasis is placed on novel interfaces to analytical instrumentation, as well as recent developments in coating materials for the SPME Arrow.
Collapse
|
8
|
Qian MC. Introduction to the Second International Flavor and Fragrance Conference. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2019; 67:13775-13777. [PMID: 31779309 DOI: 10.1021/acs.jafc.9b04188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The Second International Flavor and Fragrance Conference was successfully held on May 28-31, 2018, in Wuxi, China. The congress shared the progresses and discoveries in the research areas of flavor and fragrance perception, flavor analysis, thermal and biomediated generation of flavor, biological activities of aroma and flavor, and flavor and fragrance encapsulation and delivery technologies. This special issue collected some original research papers as well as reviews on basic taste, flavor analysis, aroma and taste characterization, essential oil bioactivity, and other related topics.
Collapse
Affiliation(s)
- Michael C Qian
- Department of Food Science and Technology , Oregon State University , Corvallis , Oregon 97330 , United States
| |
Collapse
|