1
|
Guo Q, Li J, Zhao Y, Li L, He L, Zhao F, Zhai F, Zhang M, Chen L, Chai Z, Wang S. Record High Iodate Anion Capture by a Redox-Active Cationic Polymer Network. Angew Chem Int Ed Engl 2024; 63:e202400849. [PMID: 38656826 DOI: 10.1002/anie.202400849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 03/19/2024] [Accepted: 04/23/2024] [Indexed: 04/26/2024]
Abstract
As a critical radioactive anionic contaminant, traditional adsorbents primarily remove iodate (IO3 -) through ion exchange or hard acid-hard base interactions, but suffer from limited affinity and capacity. Herein, employing the synergistic effect of ion exchange and redox, we successfully synthesized a redox-active cationic polymer network (SCU-CPN-6, [C9H10O2N5 ⋅ Cl]n) by merging guanidino groups with ion-exchange capability and phenolic groups with redox ability via a Schiff base reaction. SCU-CPN-6 exhibits a groundbreaking adsorption capacity of 896 mg/g for IO3 -. The inferior adsorption capacities of polymeric networks containing only redox (~0 mg/g) or ion exchange (232 mg/g) fragments underscore the synergistic "1+1>2" effect of the two mechanisms. Besides, SCU-CPN-6 shows excellent uptake selectivity for IO3 - in the presence of high concentrations of SO4 2-, Cl-, and NO3 -. Meanwhile, a high distribution coefficient indicates its exemplary deep-removal performance for low IO3 - concentration. The synergic strategy not only presents a breakthrough solution for the efficient removal of IO3 - but also establishes a promising avenue for the design of advanced adsorbents for diverse applications.
Collapse
Affiliation(s)
- Qi Guo
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, 215123, China
| | - Jie Li
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, 215123, China
| | - Yuting Zhao
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, 215123, China
| | - Lingyi Li
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, 215123, China
| | - Linwei He
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, 215123, China
| | - Fuqiang Zhao
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, 215123, China
| | - Fuwan Zhai
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, 215123, China
| | - Mingxing Zhang
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, 215123, China
| | - Long Chen
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, 215123, China
| | - Zhifang Chai
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, 215123, China
| | - Shuao Wang
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, 215123, China
| |
Collapse
|
2
|
Medina AS, Felmy HM, Vitale-Sullivan ME, Lackey HE, Branch SD, Bryan SA, Lines AM. Iodine and Carbonate Species Monitoring in Molten NaOH-KOH Eutectic Scrubber via Dual-Phase In Situ Raman Spectroscopy. ACS OMEGA 2022; 7:40456-40465. [PMID: 36385882 PMCID: PMC9647834 DOI: 10.1021/acsomega.2c05522] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Accepted: 10/14/2022] [Indexed: 06/16/2023]
Abstract
Molten hydroxide scrubbing of off-gas vapors is a potential process to improve safety during the operation of generation IV molten salt nuclear reactors (MSRs). MSRs produce off-gases that can be vented by the reactor core and treated via off-gas scrubbers. Molten hydroxide scrubbers focus on capturing volatile iodine radionuclides, and they can also be used to capture aerosols and particulates and to neutralize acidic species. The performance of these scrubbers depends on the chemical interactions of the scrubbing medium with the off-gas species. Knowledge of the concentration and speciation of scrubbed or target species, as well as process and environmental interferents, can enable advanced operation of MSR off-gas treatment systems. Optical online monitoring is an excellent technology to provide this information in real time, while limiting the need for operators to interact with radioactive samples through hands-on interrogation. Raman spectroscopy can provide crucial chemical information on the state of the molten eutectic during treatment in the molten phase, as well as the gas phase. In this work, Raman spectroscopy is used to detect iodine species, specifically iodate, in the molten phase of a NaOH-KOH eutectic and to construct a calibration curve of the Raman signal of those species. Additionally, a carbonate interferent is followed from the gas phase to the liquid phase as a basis for reaching a Raman-aided mass balance of the molten hydroxide eutectic scrubber system.
Collapse
|