1
|
Haake M, Aldakov D, Pérard J, Veronesi G, Tapia AA, Reuillard B, Artero V. Impact of the Surface Microenvironment on the Redox Properties of a Co-Based Molecular Cathode for Selective Aqueous Electrochemical CO 2-to-CO Reduction. J Am Chem Soc 2024; 146:15345-15355. [PMID: 38767986 DOI: 10.1021/jacs.4c03089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/22/2024]
Abstract
Electrode-confined molecular catalysts are promising systems to enable the efficient conversion of CO2 to useful products. Here, we describe the development of an original molecular cathode for CO2 reduction to CO based on the noncovalent integration of a tetraazamacrocyclic Co complex to a carbon nanotube-based matrix. Aqueous electrochemical characterization of the modified electrode allowed for clear observation of a change of redox behavior of the Co center as surface concentration was tuned, highlighting the impact of the catalyst microenvironment on its redox properties. The molecular cathode enabled efficient CO2-to-CO conversion in fully aqueous conditions, giving rise to a turnover number (TONCO) of up to 20 × 103 after 2 h of constant electrolysis at a mild overpotential (η = 450 mV) and with a faradaic efficiency for CO of about 95%. Post operando measurements using electrochemical techniques, inductively coupled plasma, X-ray photoelectron spectroscopy and X-ray absorption spectroscopy characterization of the films demonstrated that the catalysis remained of molecular nature, making this Co-based electrode a new promising alternative for molecular electrocatalytic conversion of CO2-to-CO in fully aqueous media.
Collapse
Affiliation(s)
- Matthieu Haake
- Université Grenoble Alpes, CNRS, CEA, IRIG, Laboratoire de Chimie et Biologie des Métaux, 17 Rue des Martyrs, Grenoble Cedex F-38054, France
| | - Dmitry Aldakov
- Université Grenoble Alpes, CNRS, CEA, Grenoble INP, IRIG, SyMMES, Grenoble 38000, France
| | - Julien Pérard
- Université Grenoble Alpes, CNRS, CEA, IRIG, Laboratoire de Chimie et Biologie des Métaux, 17 Rue des Martyrs, Grenoble Cedex F-38054, France
| | - Giulia Veronesi
- Université Grenoble Alpes, CNRS, CEA, IRIG, Laboratoire de Chimie et Biologie des Métaux, 17 Rue des Martyrs, Grenoble Cedex F-38054, France
| | - Antonio Aguilar Tapia
- Institut de Chimie Moléculaire de Grenoble, UAR2607 CNRS Université Grenoble Alpes, Grenoble F-38000, France
| | - Bertrand Reuillard
- Université Grenoble Alpes, CNRS, CEA, IRIG, Laboratoire de Chimie et Biologie des Métaux, 17 Rue des Martyrs, Grenoble Cedex F-38054, France
| | - Vincent Artero
- Université Grenoble Alpes, CNRS, CEA, IRIG, Laboratoire de Chimie et Biologie des Métaux, 17 Rue des Martyrs, Grenoble Cedex F-38054, France
| |
Collapse
|
2
|
Le PG, Le HTN, Kim HE, Cho S. SAM-Support-Based Electrochemical Sensor for Aβ Biomarker Detection of Alzheimer's Disease. BIOSENSORS 2023; 13:809. [PMID: 37622895 PMCID: PMC10452698 DOI: 10.3390/bios13080809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 08/01/2023] [Accepted: 08/09/2023] [Indexed: 08/26/2023]
Abstract
Alzheimer's disease has taken the spotlight as a neurodegenerative disease which has caused crucial issues to both society and the economy. Specifically, aging populations in developed countries face an increasingly serious problem due to the increasing budget for patient care and an inadequate labor force, and therefore a solution is urgently needed. Recently, diverse techniques for the detection of Alzheimer's biomarkers have been researched and developed to support early diagnosis and treatment. Among them, electrochemical biosensors and electrode modification proved their effectiveness in the detection of the Aβ biomarker at appropriately low concentrations for practice and point-of-care application. This review discusses the production and detection ability of amyloid beta, an Alzheimer's biomarker, by electrochemical biosensors with SAM support for antibody conjugation. In addition, future perspectives on SAM for the improvement of electrochemical biosensors are also proposed and discussed.
Collapse
Affiliation(s)
- Phan Gia Le
- Department of Electronic Engineering, Gachon University, Seongnam-si 13120, Republic of Korea; (P.G.L.); (H.T.N.L.)
| | - Hien T. Ngoc Le
- Department of Electronic Engineering, Gachon University, Seongnam-si 13120, Republic of Korea; (P.G.L.); (H.T.N.L.)
| | - Hee-Eun Kim
- Department of Dental Hygiene, Gachon University, Incheon 21936, Republic of Korea;
| | - Sungbo Cho
- Department of Electronic Engineering, Gachon University, Seongnam-si 13120, Republic of Korea; (P.G.L.); (H.T.N.L.)
- Department of Health Sciences and Technology (GAIHST), Gachon University, Incheon 21999, Republic of Korea
| |
Collapse
|
3
|
Clark RA, Yawitz T, Luchs L, Conrad T, Bartlebaugh O, Boyd H, Hargittai B. Tripeptide Self-Assembled Monolayers as Biocompatible Surfaces for Cytochrome c Electrochemistry. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:1414-1424. [PMID: 36688667 DOI: 10.1021/acs.langmuir.2c02682] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Biocompatible tripeptide self-assembled monolayers (SAMs) are designed with a carboxylate group on the terminal amino acid (glutamate, aspartate, or amino adipate) to electrostatically attract the lysine groups around the heme crevice in horse heart cytochrome c (cyt c), creating an electroactive protein/tripeptide/Au interfacial structure. Exposing the peptide/Au electrode to cyt c resulted in an 11 ± 3 pmol/cm2 electroactive protein surface coverage. Topographical images of the interfacial structure are obtained down to single-protein resolution by atomic force microscopy. Uniform protein monolayer assemblies are formed on the Au electrode with no major surface roughness changes. The cyt c/peptide/Au electrode systems were examined electrochemically to probe surface charge effects on the redox thermodynamics and kinetics of cyt c. Neutralization of protein surface charge due to adsorption on anionic COOH-terminated SAMs was found to change the formal potential, as determined by cyclic voltammetry. The cyt c/peptide/Au electrodes exhibit formal potentials shifted to more positive values, have a surface carboxylic acid pKa of 6 or higher, and produce effective cyt c surface charges (Zox) of -6 to -14. The Marcus theory is utilized to determine the protein electron transfer rates, which are ∼5 times faster for cyt c/tripeptide/Au compared to cyt c/11-mercaptoundecanoic acid SAMs of similar chain lengths.
Collapse
Affiliation(s)
- Rose A Clark
- Department of Chemistry, Saint Francis University, 169 Lakeview Drive, P.O. Box 600, Loretto, Pennsylvania15940, United States
| | - Tanner Yawitz
- Department of Chemistry, Saint Francis University, 169 Lakeview Drive, P.O. Box 600, Loretto, Pennsylvania15940, United States
| | - Logan Luchs
- Department of Chemistry, Saint Francis University, 169 Lakeview Drive, P.O. Box 600, Loretto, Pennsylvania15940, United States
| | - Tiffany Conrad
- Department of Chemistry, Saint Francis University, 169 Lakeview Drive, P.O. Box 600, Loretto, Pennsylvania15940, United States
| | - Owen Bartlebaugh
- Department of Chemistry, Saint Francis University, 169 Lakeview Drive, P.O. Box 600, Loretto, Pennsylvania15940, United States
| | - Hannah Boyd
- Department of Chemistry, Saint Francis University, 169 Lakeview Drive, P.O. Box 600, Loretto, Pennsylvania15940, United States
| | - Balazs Hargittai
- Department of Chemistry, Saint Francis University, 169 Lakeview Drive, P.O. Box 600, Loretto, Pennsylvania15940, United States
| |
Collapse
|
4
|
Electrochemical ELASA: improving early cancer detection and monitoring. Anal Bioanal Chem 2023:10.1007/s00216-023-04546-5. [PMID: 36702904 DOI: 10.1007/s00216-023-04546-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 01/10/2023] [Accepted: 01/13/2023] [Indexed: 01/28/2023]
Abstract
The discovery of new molecular biomarkers of cancer during the last decades and the development of new diagnostic devices exploiting those have significantly contributed to the clinical analysis of cancer and to improve the outcomes. Among those, liquid biopsy sensors exploiting aptamers for the detection of cancer biomarkers in body fluids are useful and accurate tools for a fast and inexpensive non-invasive screening of population. The incorporation of aptamers in electrochemical sandwich biosensors using enzyme labels, a so-called ELASA, has demonstrated its utility to improve the detection schemes. In this review, we overview the existing ELASA assays for numerous cancer biomarkers as alternatives to the traditional ELISA and discuss their possibilities to reach the market, currently dominated by optical immunoassays.
Collapse
|