Luu CH, Nguyen N, Ta HT. Unravelling Surface Modification Strategies for Preventing Medical Device-Induced Thrombosis. Adv Healthc Mater 2024; 13:e2301039. [PMID: 37725037 PMCID: PMC11468451 DOI: 10.1002/adhm.202301039] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 08/29/2023] [Indexed: 09/21/2023]
Abstract
The use of biomaterials in implanted medical devices remains hampered by platelet adhesion and blood coagulation. Thrombus formation is a prevalent cause of failure of these blood-contacting devices. Although systemic anticoagulant can be used to support materials and devices with poor blood compatibility, its negative effects such as an increased chance of bleeding, make materials with superior hemocompatibility extremely attractive, especially for long-term applications. This review examines blood-surface interactions, the pathogenesis of clotting on blood-contacting medical devices, popular surface modification techniques, mechanisms of action of anticoagulant coatings, and discusses future directions in biomaterial research for preventing thrombosis. In addition, this paper comprehensively reviews several novel methods that either entirely prevent interaction between material surfaces and blood components or regulate the reaction of the coagulation cascade, thrombocytes, and leukocytes.
Collapse
Affiliation(s)
- Cuong Hung Luu
- School of Environment and ScienceGriffith UniversityNathanQueensland4111Australia
- Queensland Micro‐ and Nanotechnology CentreGriffith UniversityNathanQueensland4111Australia
| | - Nam‐Trung Nguyen
- School of Environment and ScienceGriffith UniversityNathanQueensland4111Australia
- Queensland Micro‐ and Nanotechnology CentreGriffith UniversityNathanQueensland4111Australia
| | - Hang Thu Ta
- School of Environment and ScienceGriffith UniversityNathanQueensland4111Australia
- Queensland Micro‐ and Nanotechnology CentreGriffith UniversityNathanQueensland4111Australia
| |
Collapse
|
2
|
Wu J, Liu W, Ngai T. Total internal reflection microscopy: a powerful tool for exploring interactions and dynamics near interfaces. SOFT MATTER 2023. [PMID: 37314857 DOI: 10.1039/d3sm00085k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The occurrence of many micro/macrophenomena is closely related to interactions and dynamics near interfaces. Hence, developing powerful tools for characterizing near-interface interactions and dynamics has attached great importance among researchers. In this review, we introduce a noninvasive and ultrasensitive technique called total internal reflection microscopy (TIRM). The principles of TIRM are introduced first, demonstrating the characteristics of this technique. Then, typical measurements with TIRM and the recent development of the technique are reviewed in detail. At the end of the review, we highlight the great progress of TIRM during the past several decades and show its potential to be more influential in measuring interactions and dynamics near interfaces in various research fields.
Collapse
Affiliation(s)
- Jiahao Wu
- Department of Chemistry, The Chinese University of Hong Kong, N.T., Shatin, Hong Kong, China.
| | - Wei Liu
- Key Laboratory of Synthetic and Biological Colloids, Ministry of Education & School of Chemical and Material Engineering, Jiangnan University, Wuxi, China.
| | - To Ngai
- Department of Chemistry, The Chinese University of Hong Kong, N.T., Shatin, Hong Kong, China.
| |
Collapse
|
3
|
Yang H, Xu Z, Xu Z, Li Y. Mini-Review of Biofilm Interactions with Surface Materials in Industrial Piping System. MEMBRANES 2023; 13:125. [PMID: 36837628 PMCID: PMC9961356 DOI: 10.3390/membranes13020125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 01/16/2023] [Accepted: 01/17/2023] [Indexed: 06/18/2023]
Abstract
The growth of biofilm, which is caused by microorganism accumulation and growth on wetted surfaces, may damage industrial piping systems, increase maintenance and cleaning costs for the system sterilization, and even divulge the immune system into high risk. This article systematically analyzes the biofilm interactions with piping surface materials from the perspectives of physical convection, and biological and chemical adhesion. The thermodynamics of the flow, bacterial surface sensing, and bio-communication are the most critical factors for biofilm attachment. Furthermore, experimental analysis methods as well as biofilm control and removal approaches, are also included in this study. Finally, the resistance and growth of biofilm, as well as the practical and advanced methodology to control the biofilm and challenges associated with technology, are also discussed. Moreover, this paper may also offer a significant reference for the practice and strategic applications to address the biofilm resistance issues in industrial piping.
Collapse
Affiliation(s)
- Haoyi Yang
- NUS College of Design and Engineering, National University of Singapore, Singapore 118429, Singapore
| | - Zezheng Xu
- UNSW Environment Leadership Program, The University of New South Wales, Kensington, NSW 2052, Australia
| | - Zetong Xu
- Qingdao Huanghai Vocational Institute, Qingdao 266555, China
| | - Yuanzhe Li
- School of Materials Science & Engineering, Nanyang Technological University, Singapore 639798, Singapore
| |
Collapse
|
4
|
Palai D, Tahara H, Chikami S, Latag GV, Maeda S, Komura C, Kurioka H, Hayashi T. Prediction of Serum Adsorption onto Polymer Brush Films by Machine Learning. ACS Biomater Sci Eng 2022; 8:3765-3772. [PMID: 35905395 DOI: 10.1021/acsbiomaterials.2c00441] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Using machine learning based on a random forest (RF) regression algorithm, we attempted to predict the amount of adsorbed serum protein on polymer brush films from the films' physicochemical information and the monomers' chemical structures constituting the films using a RF model. After the training of the RF model using the data of polymer brush films synthesized from five different types of monomers, the model became capable of predicting the amount of adsorbed protein from the chemical structure, physicochemical properties of monomer molecules, and structural parameters (density and thickness of the films). The analysis of the trained RF quantitatively provided the importance of each structural parameter and physicochemical properties of monomers toward serum protein adsorption (SPA). The ranking for the significance of the parameters agrees with our general understanding and perception. Based on the results, we discuss the correlation between brush film's physical properties (such as thickness and density) and SPA and attempt to provide a guideline for the design of antibiofouling polymer brush films.
Collapse
Affiliation(s)
- Debabrata Palai
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 4259 Nagatsuta-Cho Midori-Ku, Yokohama, Kanagawa 226-8502, Japan
| | - Hiroyuki Tahara
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 4259 Nagatsuta-Cho Midori-Ku, Yokohama, Kanagawa 226-8502, Japan
| | - Shunta Chikami
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 4259 Nagatsuta-Cho Midori-Ku, Yokohama, Kanagawa 226-8502, Japan
| | - Glenn Villena Latag
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 4259 Nagatsuta-Cho Midori-Ku, Yokohama, Kanagawa 226-8502, Japan
| | - Shoichi Maeda
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 4259 Nagatsuta-Cho Midori-Ku, Yokohama, Kanagawa 226-8502, Japan
| | - Chisato Komura
- Research Institute for Advanced Materials and Devices, Kyocera Corporation, 3-5-3 Hikaridai, Seika-Cho, Soraku-gun, Kyoto 619-0237, Japan
| | - Hideharu Kurioka
- Research Institute for Advanced Materials and Devices, Kyocera Corporation, 3-5-3 Hikaridai, Seika-Cho, Soraku-gun, Kyoto 619-0237, Japan
| | - Tomohiro Hayashi
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 4259 Nagatsuta-Cho Midori-Ku, Yokohama, Kanagawa 226-8502, Japan.,The Institute for Solid State Physics, the University of Tokyo, 5-1-5, Kashiwanoha, Kashiwa, Chiba, 277-0882, Japan
| |
Collapse
|
5
|
Cao F, Li Y, Wu J, Liu W, Ngai T. Measurements of interactions between fluorescent molecules and polyethylene glycol self-assembled monolayers. SOFT MATTER 2021; 18:236-243. [PMID: 34874390 DOI: 10.1039/d1sm01329g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Blocking the non-specific binding of fluorescent biomolecules to substrates is one of the most important approaches to minimize the background noise in single-molecule fluorescence detection. Polyethylene glycol (PEG) and its derivatives are the most frequently used self-assembled monolayers (SAMs) for surface passivation because they are particularly effective to reduce the adsorption of a majority of biomolecules. Most studies related to PEG SAMs focus only on the interactions between biomolecules and substrates, while few reports exist in which the interactions between fluorophores and organosilane SAMs are directly examined. The objective of this study is to try to clarify the interactions between fluorescein isothiocyanate (FITC) and PEG SAMs at different ionic strengths. Total internal reflection microscopy (TIRM) was utilized for quantitative analysis of the interactions. At low ionic strength, long-range attractions between FITC-modified polystyrene-silica particles and PEG SAM grafting substrates were observed, even though both of them had an ensemble-averaged negative charge. The origin of this attraction could be correlated to their nonuniformly charged surfaces. At high ionic strength, van der Waals attraction at short distances was measured as the electrostatic interactions were completely screened. Due to the polarizability of the FITC molecule, the van der Waals attractions increased with the thickness of the PEG SAMs. This phenomenon is explained by the hydration shell of the PEG SAMs.
Collapse
Affiliation(s)
- Feng Cao
- Department of Chemistry, The Chinese University of Hong Kong, N.T., Shatin, Hong Kong, China.
| | - Yinan Li
- Department of Chemistry, The Chinese University of Hong Kong, N.T., Shatin, Hong Kong, China.
| | - Jiahao Wu
- Department of Chemistry, The Chinese University of Hong Kong, N.T., Shatin, Hong Kong, China.
| | - Wei Liu
- Department of Chemistry, The Chinese University of Hong Kong, N.T., Shatin, Hong Kong, China.
| | - To Ngai
- Department of Chemistry, The Chinese University of Hong Kong, N.T., Shatin, Hong Kong, China.
| |
Collapse
|
6
|
Kuchinka J, Willems C, Telyshev DV, Groth T. Control of Blood Coagulation by Hemocompatible Material Surfaces-A Review. Bioengineering (Basel) 2021; 8:215. [PMID: 34940368 PMCID: PMC8698751 DOI: 10.3390/bioengineering8120215] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Revised: 12/10/2021] [Accepted: 12/12/2021] [Indexed: 11/16/2022] Open
Abstract
Hemocompatibility of biomaterials in contact with the blood of patients is a prerequisite for the short- and long-term applications of medical devices such as cardiovascular stents, artificial heart valves, ventricular assist devices, catheters, blood linings and extracorporeal devices such as artificial kidneys (hemodialysis), extracorporeal membrane oxygenation (ECMO) and cardiopulmonary bypass. Although lower blood compatibility of materials and devices can be handled with systemic anticoagulation, its side effects, such as an increased bleeding risk, make materials that have a better hemocompatibility highly desirable, particularly in long-term applications. This review provides a short overview on the basic mechanisms of blood coagulation including plasmatic coagulation and blood platelets, as well as the activation of the complement system. Furthermore, a survey on concepts for tailoring the blood response of biomaterials to improve the hemocompatibility of medical devices is given which covers different approaches that either inhibit interaction of material surfaces with blood components completely or control the response of the coagulation system, blood platelets and leukocytes.
Collapse
Affiliation(s)
- Janna Kuchinka
- Department Biomedical Materials, Institute of Pharmacy, Martin Luther University Halle-Wittenberg, 06120 Halle (Saale), Germany; (J.K.); (C.W.)
| | - Christian Willems
- Department Biomedical Materials, Institute of Pharmacy, Martin Luther University Halle-Wittenberg, 06120 Halle (Saale), Germany; (J.K.); (C.W.)
| | - Dmitry V. Telyshev
- Institute of Biomedical Systems, National Research University of Electronic Technology, Zelenograd, 124498 Moscow, Russia;
- Laboratory of Biomedical Nanotechnologies, Institute of Bionic Technologies and Engineering, I.M. Sechenov First Moscow State University, 119991 Moscow, Russia
| | - Thomas Groth
- Department Biomedical Materials, Institute of Pharmacy, Martin Luther University Halle-Wittenberg, 06120 Halle (Saale), Germany; (J.K.); (C.W.)
- Laboratory of Biomedical Nanotechnologies, Institute of Bionic Technologies and Engineering, I.M. Sechenov First Moscow State University, 119991 Moscow, Russia
- Interdisciplinary Center of Materials Science, Martin Luther University Halle-Wittenberg, 06120 Halle (Saale), Germany
| |
Collapse
|
7
|
Kureha T, Hayashi K, Li X, Shibayama M. Mechanical properties of temperature-responsive gels containing ethylene glycol in their side chains. SOFT MATTER 2020; 16:10946-10953. [PMID: 33146225 DOI: 10.1039/d0sm01436b] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The mechanical properties of temperature-responsive and biocompatible poly(oligo-ethylene glycol methyl ether methacrylate)-based gels were investigated using dynamic viscoelasticity measurements so as to find applications in tissue and biomedical engineering. The gels were copolymerized using two ethylene glycol methacrylate monomers with diethylene glycol side chains: diethylene glycol methacrylate (MeO2MA), which contains two ethylene oxide units, and oligo-ethylene glycol methyl ether methacrylate (OEGMA) with either four or five ethylene oxide units. The storage (G') and loss (G'') moduli of these gels exhibit unique temperature-responsive behavior and depend on the copolymerization ratio. In MeO2MA-rich gels, phase separation occurred with increasing temperature, resulting in a significant increase in G' and the disappearance of the frequency dependence of G''. Although phase separation of OEGMA-rich gels was also observed with increasing temperature, it resulted in only a slight increase in the storage modulus due to the steric hindrance of the side chain. The mechanical properties of these gels are thus found to be strongly affected by a slight difference in the number of ethylene oxide groups in their side chains.
Collapse
Affiliation(s)
- Takuma Kureha
- Department of Frontier Materials Chemistry, Graduate School of Science and Technology, Hirosaki University, 3 Bunkyo-cho, Hirosaki 036-8561, Japan.
| | | | | | | |
Collapse
|
8
|
Surface characterization of amphiphilic block copolymers possessing polyisoprene and poly[tri(ethylene glycol) methacrylate] segments and the effect of side chain ω-function on surface energy. POLYMER 2020. [DOI: 10.1016/j.polymer.2020.122257] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
9
|
Cao F, Wu J, Li Y, Ngai T. Measurements of Particle-Surface Interactions in Both Equilibrium and Nonequilibrium Systems. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2019; 35:8910-8920. [PMID: 31192606 DOI: 10.1021/acs.langmuir.9b00626] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Total internal reflection microscopy (TIRM) is a passive technique that measures colloidal interactions in aqueous solution. A traditional Boltzmann method requires that particles must fluctuate around equilibrium positions for a long time. A method based on multiparticle tracking and drift velocity method was developed to measure interactions in both equilibrium and nonequilibrium systems. This method relaxed the limitation of the traditional Boltzmann method and do not require any external force like optical tweezer. Theoretical predictions of particle sedimentation under the influence of various forces were investigated to determine the proper particle size and solution properties. We found that the polystyrene (PS) particle with a size of 2.1 μm took the longest time to finish sedimentation, and 5% (w/w) sucrose was chosen to suppress the Brownian motion. For single and ensemble particles in equilibrium, the experimental diffusion coefficients and potential energy profiles were consistent with the theoretical prediction. In nonequilibrium experiments, the van der Waals force between the bare/hybrid particles and flat surface was measured, and the silica shell acted to strengthen the van der Waals attraction. This method extends the application of TIRM to nonequilibrium systems without any active control. Moreover, the silica-coated PS core-shell hybrid particles facilitate surface modification with a variety of active chemicals. It would be a great advantage to measure all kinds of long-range interactions between surface-modified particles and surface in aqueous solution with TIRM.
Collapse
Affiliation(s)
- Feng Cao
- Department of Chemistry , The Chinese University of Hong Kong , Shatin , N.T. 00852 , Hong Kong
| | - Jiahao Wu
- Department of Chemistry , The Chinese University of Hong Kong , Shatin , N.T. 00852 , Hong Kong
| | - Yunxing Li
- Department of Chemistry , The Chinese University of Hong Kong , Shatin , N.T. 00852 , Hong Kong
- Key Laboratory of Synthetic and Biological Colloids, Ministry of Education, School of Chemical and Material Engineering , Jiangnan University , Wuxi 214122 , China
| | - To Ngai
- Department of Chemistry , The Chinese University of Hong Kong , Shatin , N.T. 00852 , Hong Kong
| |
Collapse
|