Bayer JD, Sobota V, Bear LR, Haïssaguerre M, Vigmond EJ. A His bundle pacing protocol for suppressing ventricular arrhythmia maintenance and improving defibrillation efficacy. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 253:108239. [PMID: 38823116 DOI: 10.1016/j.cmpb.2024.108239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 05/18/2024] [Accepted: 05/21/2024] [Indexed: 06/03/2024]
Abstract
BACKGROUND The excitable gap (EG), defined as the excitable tissue between two subsequent wavefronts of depolarization, is critical for maintaining reentry that underlies deadly ventricular arrhythmias. EG in the His-Purkinje Network (HPN) plays an important role in the maintenance of electrical wave reentry that underlies these arrhythmias. OBJECTIVE To determine if rapid His bundle pacing (HBP) during reentry reduces the amount of EG in the HPN and ventricular myocardium to suppress reentry maintenance and/or improve defibrillation efficacy. METHODS In a virtual human biventricular model, reentry was initiated with rapid line pacing followed by HBP delivered for 3, 6, or 9 s at pacing cycle lengths (PCLs) ranging from 10 to 300 ms (n=30). EG was calculated independently for the HPN and myocardium over each PCL. Defibrillation efficacy was assessed for each PCL by stimulating myocardial surface EG with delays ranging from 0.25 to 9 s (increments of 0.25 s, n=36) after the start of HBP. Defibrillation was successful if reentry terminated within 1 s after EG stimulation. This defibrillation protocol was repeated without HBP. To test the approach under different pathological conditions, all protocols were repeated in the model with right (RBBB) or left (LBBB) bundle branch block. RESULTS Compared to without pacing, HBP for >3 seconds reduced average EG in the HPN and myocardium across a broad range of PCLs for the default, RBBB, and LBBB models. HBP >6 seconds terminated reentrant arrhythmia by converting HPN activation to a sinus rhythm behavior in the default (6/30 PCLs) and RBBB (7/30 PCLs) models. Myocardial EG stimulation during HBP increased the number of successful defibrillation attempts by 3%-19% for 30/30 PCLs in the default model, 3%-6% for 14/30 PCLs in the RBBB model, and 3%-11% for 27/30 PCLs in the LBBB model. CONCLUSION HBP can reduce the amount of excitable gap and suppress reentry maintenance in the HPN and myocardium. HBP can also improve the efficacy of low-energy defibrillation approaches targeting excitable myocardium. HBP during reentrant arrhythmias is a promising anti-arrhythmic and defibrillation strategy.
Collapse
Affiliation(s)
- Jason D Bayer
- IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, 33600, Pessac-Bordeaux, France; University of Bordeaux, Institut de Mathématiques de Bordeaux, UMR 5251, 33400, Talence, France.
| | - Vladimír Sobota
- IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, 33600, Pessac-Bordeaux, France; University of Bordeaux, Institut de Mathématiques de Bordeaux, UMR 5251, 33400, Talence, France
| | - Laura R Bear
- IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, 33600, Pessac-Bordeaux, France
| | - Michel Haïssaguerre
- IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, 33600, Pessac-Bordeaux, France; Haut-Lévêque Cardiology Hospital, University Hospital Center (CHU) of Bordeaux, Pessac, France
| | - Edward J Vigmond
- IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, 33600, Pessac-Bordeaux, France; University of Bordeaux, Institut de Mathématiques de Bordeaux, UMR 5251, 33400, Talence, France
| |
Collapse
|
2
|
The Purkinje network plays a major role in low-energy ventricular defibrillation. Comput Biol Med 2021; 141:105133. [PMID: 34954609 DOI: 10.1016/j.compbiomed.2021.105133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 12/10/2021] [Accepted: 12/10/2021] [Indexed: 11/20/2022]
Abstract
BACKGROUND During ventricular fibrillation (VF), targeting the excitable gap (EG) of reentry throughout the myocardium with low-energy surface stimulation shows promise for painless defibrillation. However, the Purkinje network may provide alternative pathways for reentry to evade termination. This study investigates the role of the Purkinje network in painless defibrillation. METHODS In a computational human biventricular model featuring a Purkinje network, VF was initiated with 4 Hz epicardial pacing. Defibrillation was attempted by stimulating myocardial surface EG with a low-energy 2 ms duration pulse at 2x stimulus capture, which was administered at coupling intervals incremented by 0.25 s between 0.25 and 5 s after VF initiation. Defibrillation was accomplished if reentry ceased ≤ 1 s after the defibrillation pulse. The protocol was repeated with the Purkinje network and myocardial surface EG stimulated simultaneously, and again after uncoupling the Purkinje network from the myocardium. RESULTS VF with the Purkinje network coupled and uncoupled had comparable dominant frequency in the left (3.81 ± 0.44 versus 3.77 ± 0.53 Hz) and right (3.80 ± 0.37 versus 3.76 ± 0.48 Hz) ventricles. When uncoupling the Purkinje network, myocardial surface EG stimulation terminated VF for all defibrillation pulses. When coupled, myocardial EG surface stimulation terminated VF for only 55% of the defibrillation pulses, but improved to 100% when stimulated simultaneously with Purkinje network EG. Defibrillation failures were attributed to EG evading stimulation in the Purkinje network. CONCLUSIONS Defibrillation that exclusively targets myocardium can fail due to accessory pathways in the Purkinje network that allow for reentrant activity to evade termination and maintain VF. Painless defibrillation strategies should be adapted to include the Purkinje network.
Collapse
|
3
|
Qian S, Connolly A, Mendonca-Costa C, Campos F, Williams SE, Whitaker J, Rinaldi CA, Bishop MJ. An in-silico assessment of efficacy of two novel intra-cardiac electrode configurations versus traditional anti-tachycardia pacing therapy for terminating sustained ventricular tachycardia. Comput Biol Med 2021; 139:104987. [PMID: 34741904 PMCID: PMC8669079 DOI: 10.1016/j.compbiomed.2021.104987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 10/24/2021] [Accepted: 10/24/2021] [Indexed: 11/06/2022]
Abstract
The implanted cardioverter defibrillator (ICD) is an effective direct therapy for the treatment of cardiac arrhythmias, including ventricular tachycardia (VT). Anti-tachycardia pacing (ATP) is often applied by the ICD as the first mode of therapy, but is often found to be ineffective, particularly for fast VTs. In such cases, strong, painful and damaging backup defibrillation shocks are applied by the device. Here, we propose two novel electrode configurations: "bipolar" and "transmural" which both combine the concept of targeted shock delivery with the advantage of reduced energy required for VT termination. We perform an in silico study to evaluate the efficacy of VT termination by applying one single (low-energy) monophasic shock from each novel configuration, comparing with conventional ATP therapy. Both bipolar and transmural configurations are able to achieve a higher efficacy (93% and 85%) than ATP (45%), with energy delivered similar to and two orders of magnitudes smaller than conventional ICD defibrillation shocks, respectively. Specifically, the transmural configuration (which applies the shock vector directly across the scar substrate sustaining the VT) is most efficient, requiring typically less than 1 J shock energy to achieve a high efficacy. The efficacy of both bipolar and transmural configurations are higher when applied to slow VTs (100% and 97%) compared to fast VTs (57% and 29%). Both novel electrode configurations introduced are able to improve electrotherapy efficacy while reducing the overall number of required therapies and need for strong backup shocks.
Collapse
Affiliation(s)
- Shuang Qian
- School of Biomedical Engineering and Imaging Sciences, Rayne Institute, King's College London, 4th Floor, Lambeth Wing, St. Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, United Kingdom.
| | - Adam Connolly
- Invicro, Burlington Danes Building, Du Cane Rd, London, W12 0N, United Kingdom
| | - Caroline Mendonca-Costa
- School of Biomedical Engineering and Imaging Sciences, Rayne Institute, King's College London, 4th Floor, Lambeth Wing, St. Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, United Kingdom
| | - Fernando Campos
- School of Biomedical Engineering and Imaging Sciences, Rayne Institute, King's College London, 4th Floor, Lambeth Wing, St. Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, United Kingdom
| | - Steven E Williams
- School of Biomedical Engineering and Imaging Sciences, Rayne Institute, King's College London, 4th Floor, Lambeth Wing, St. Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, United Kingdom
| | - John Whitaker
- School of Biomedical Engineering and Imaging Sciences, Rayne Institute, King's College London, 4th Floor, Lambeth Wing, St. Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, United Kingdom; Department of Cardiology, Guy's and St Thomas' Hospital, London, SE1 7EH, United Kingdom
| | - Christopher A Rinaldi
- School of Biomedical Engineering and Imaging Sciences, Rayne Institute, King's College London, 4th Floor, Lambeth Wing, St. Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, United Kingdom; Department of Cardiology, Guy's and St Thomas' Hospital, London, SE1 7EH, United Kingdom
| | - Martin J Bishop
- School of Biomedical Engineering and Imaging Sciences, Rayne Institute, King's College London, 4th Floor, Lambeth Wing, St. Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, United Kingdom
| |
Collapse
|