1
|
Gu H, Li J. Mathematical model of ion chronogram from in-tube solid-phase microextraction device coupled with mass spectrometry and optimization framework. J Chromatogr A 2024; 1731:465167. [PMID: 39033707 DOI: 10.1016/j.chroma.2024.465167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2024] [Revised: 07/08/2024] [Accepted: 07/13/2024] [Indexed: 07/23/2024]
Abstract
A mathematical description and experimental outputs exhibited that an ion chronogram from an in-tube solid-phase microextraction (SPME) device linked with mass spectrometry (in-tube-SPME-MS) generally appears as a right-skew unimodal signal with a heavy right tail. Analogous to liquid chromatography coupled with mass spectrometry (LC-MS), in-tube-SPME-MS can utilize the area under its produced ion chronogram for regression analysis and has been shown to be a potential approach for fast quantification of analyte. Different level of unimodity of signal in the ion chronogram could positively or negatively affect the choice of the area used for quantification and finally impact on analysis sensitivity and time efficiency of in-tube-SPME-MS. In the paper, we showed that different in-tube SPME design choices and elution experimental setups produce ion chronograms with controllable varying unimodal peak shape patterns. An improved mathematical model was built based on the plate theory of chromatography and the Van Deemter equation to quantitatively describe the elution process from in-tube-SPME device. A computer simulation was implemented to predict ion chronograms and the results were compared with experimental ion chronograms to show the effectiveness of the model. An optimization framework was further presented based on the model to identify optimal device designs (length and diameter of device) and experimental parameters (flow rate) to track targeted ion chronograms with "desired" peak shape patterns. Empirical elution experiments with the in-tube SPME devices adopting optimized geometric parameters and optimal experimental setups confirmed the consistency between the experimental ion chronograms and the numerical simulations to a certain level.
Collapse
Affiliation(s)
- Hao Gu
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China.
| | - Jiwen Li
- Hanbot Institute, Yovole Networks Inc., Shanghai 200433, China.
| |
Collapse
|
2
|
Gu H, Li J, Liang Q, Xu W. Solid phase microextraction device coupled with miniature mass spectrometry and mathematical model of its ion chronogram. Talanta 2024; 271:125651. [PMID: 38262130 DOI: 10.1016/j.talanta.2024.125651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 01/04/2024] [Accepted: 01/06/2024] [Indexed: 01/25/2024]
Abstract
Modern solid phase microextraction (SPME) device linked with mass spectrometry (SPME-MS) has evolved from producing ion chronogram as flat noisy signal to as unimodal-like signal. We designed a SPME device, which is closer in morphology to LC column, linked it with a miniature mass spectrometer (SPME-Mini MS), and proposed a mathematical model that elution of compound from the SPME device is equivalent to overlay of elution of the compound from the infinite LC columns with the lengths between 0 and the length of the device and it can generate an ion chronogram as right-skew unimodal signal. Rhodamine B as analyte was used for experimental verification and its unimodal signal was used to fit the parameters of a computer simulation program based on the model. The experimental results and simulations empirically cross-confirmed that SPME-Mini MS can generate ion chronogram as clean right-skew unimodal signal. Furthermore, the SPME-Mini MS system was used for quantitative analysis of psychotropic drugs (i.e. risperidone and aripiprazole) in artificial urine. The results preliminarily demonstrated that the system can utilize area under unimodal signal for quantitative analysis and has potential to be applied for on-site, fast and accurate quantification of drugs and other compounds.
Collapse
Affiliation(s)
- Hao Gu
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China.
| | - Jiwen Li
- Hanbot Institute, Yovole Networks Inc, Shanghai, 200433, China.
| | - Qiong Liang
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China
| | - Wei Xu
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China
| |
Collapse
|
3
|
Krebs F, Zagst H, Stein M, Ratih R, Minkner R, Olabi M, Hartung S, Scheller C, Lapizco-Encinas BH, Sänger-van de Griend C, García CD, Wätzig H. Strategies for capillary electrophoresis: Method development and validation for pharmaceutical and biological applications-Updated and completely revised edition. Electrophoresis 2023; 44:1279-1341. [PMID: 37537327 DOI: 10.1002/elps.202300158] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 07/19/2023] [Indexed: 08/05/2023]
Abstract
This review is in support of the development of selective, precise, fast, and validated capillary electrophoresis (CE) methods. It follows up a similar article from 1998, Wätzig H, Degenhardt M, Kunkel A. "Strategies for capillary electrophoresis: method development and validation for pharmaceutical and biological applications," pointing out which fundamentals are still valid and at the same time showing the enormous achievements in the last 25 years. The structures of both reviews are widely similar, in order to facilitate their simultaneous use. Focusing on pharmaceutical and biological applications, the successful use of CE is now demonstrated by more than 600 carefully selected references. Many of those are recent reviews; therefore, a significant overview about the field is provided. There are extra sections about sample pretreatment related to CE and microchip CE, and a completely revised section about method development for protein analytes and biomolecules in general. The general strategies for method development are summed up with regard to selectivity, efficiency, precision, analysis time, limit of detection, sample pretreatment requirements, and validation.
Collapse
Affiliation(s)
- Finja Krebs
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Holger Zagst
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Matthias Stein
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Ratih Ratih
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Surabaya, Surabaya, East Java, Indonesia
| | - Robert Minkner
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Mais Olabi
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Sophie Hartung
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Christin Scheller
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Blanca H Lapizco-Encinas
- Department of Biomedical Engineering, Kate Gleason College of Engineering, Rochester Institute of Technology, Rochester, New York, USA
| | - Cari Sänger-van de Griend
- Kantisto BV, Baarn, The Netherlands
- Department of Medicinal Chemistry, Faculty of Pharmacy, Uppsala Universitet, Uppsala, Sweden
| | - Carlos D García
- Department of Chemistry, Clemson University, Clemson, South Carolina, USA
| | - Hermann Wätzig
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| |
Collapse
|
4
|
Chen D, Liu F, Rong Y, Qi M, Li Y, Shi X, Xie Y, Xu X. Coupling in-syringe kapok fiber-supported liquid-phase microextraction with flow injection-mass spectrometry for rapid and green biofluid analysis: Determination of antidepressants as an example. J Pharm Biomed Anal 2023; 229:115380. [PMID: 37011550 DOI: 10.1016/j.jpba.2023.115380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/21/2023] [Accepted: 03/29/2023] [Indexed: 04/03/2023]
Abstract
Quantification of substances in biofluid samples (e.g., urine, blood, and cerebrospinal fluids) are useful for clinical diagnosis. In current study, a rapid and green strategy by coupling in-syringe kapok fiber-supported liquid-phase microextraction with flow-injection mass spectrometry was proposed. The natural kapok fiber was used as an oily extraction solvent (e.g., n-octanol) support material, and an in-syringe extraction device was conveniently constructed. The whole extraction processes, including sampling, washing and desorption, were conveniently conducted by simply pulling/pushing the syringe plunger, enabling rapid analyte enrichment and sample purification. The follow-up flow injection-mass spectrometry detection enabled rapid and high throughput analysis. As an example, the proposed method was applied to analyze antidepressants in plasma/urine, showing satisfied linearities (R2 ≥0.993) in ranges of 0.2-1000 ng/mL. By employing the in-syringe extraction method prior to flow injection-mass spectrometry detection, the LOQs in plasma and urine were reduced by 25-80 folds and 5-25 folds, respectively. Besides, by employing ethanol and 80% ethanol as the desorption solvent and carrier solvent, respectively, the analytical method showed excellent greenness. In general, the integrated method provides a promising choice for rapid and green biofluid analysis.
Collapse
Affiliation(s)
- Di Chen
- Key Laboratory of Targeting Therapy and Diagnosis for Critical Diseases of Henan Province, and School of Pharmaceutical Sciences, Zhengzhou University, 100 Kexue Avenue, Zhengzhou 450001, China
| | - Fanglin Liu
- Key Laboratory of Targeting Therapy and Diagnosis for Critical Diseases of Henan Province, and School of Pharmaceutical Sciences, Zhengzhou University, 100 Kexue Avenue, Zhengzhou 450001, China
| | - Ying Rong
- Key Laboratory of Targeting Therapy and Diagnosis for Critical Diseases of Henan Province, and School of Pharmaceutical Sciences, Zhengzhou University, 100 Kexue Avenue, Zhengzhou 450001, China
| | - Menghui Qi
- Key Laboratory of Targeting Therapy and Diagnosis for Critical Diseases of Henan Province, and School of Pharmaceutical Sciences, Zhengzhou University, 100 Kexue Avenue, Zhengzhou 450001, China
| | - Yanyan Li
- Key Laboratory of Targeting Therapy and Diagnosis for Critical Diseases of Henan Province, and School of Pharmaceutical Sciences, Zhengzhou University, 100 Kexue Avenue, Zhengzhou 450001, China
| | - Xuezhong Shi
- College of Public Health, Zhengzhou University, Zhengzhou 450001, China
| | - Ya Xie
- Department of Obstetrics and Gynecology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China.
| | - Xia Xu
- Key Laboratory of Targeting Therapy and Diagnosis for Critical Diseases of Henan Province, and School of Pharmaceutical Sciences, Zhengzhou University, 100 Kexue Avenue, Zhengzhou 450001, China.
| |
Collapse
|
5
|
Salim H, Pont L, Giménez E, Benavente F. On-line aptamer affinity solid-phase extraction direct mass spectrometry for the rapid analysis of α-synuclein in blood. Anal Chim Acta 2023; 1256:341149. [PMID: 37037631 DOI: 10.1016/j.aca.2023.341149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Revised: 03/20/2023] [Accepted: 03/26/2023] [Indexed: 03/28/2023]
Abstract
On-line aptamer affinity solid-phase extraction direct mass spectrometry (AA-SPE-MS) is presented for the rapid purification, preconcentration, and characterization of α-synuclein (α-syn), which is a protein biomarker related to Parkinson's disease. Valve-free AA-SPE-MS is easily implemented using the typical SPE microcartridges and instrumental set-up necessary for on-line aptamer affinity solid-phase extraction capillary electrophoresis-mass spectrometry (AA-SPE-CE-MS). The essential requirement is substituting the application of the separation voltage by a pressure of 100 mbar for mobilization of the eluted protein through the capillary towards the mass spectrometer. Under optimized conditions with recombinant α-syn, repeatability is good in terms of migration time and peak area (percent relative standard deviation (%RSD) values (n = 3) are 1.3 and 6.6% at 1 μg mL-1, respectively). The method is satisfactorily linear between 0.025 and 5 μg mL-1 (R2 > 0.986), and limit of detection (LOD) is 0.02 μg mL-1 (i.e. 1000, 500, and 10 times lower than by CE-MS, direct MS, and AA-SPE-CE-MS, respectively). The established AA-SPE-MS method is further compared with AA-SPE-CE-MS, including for the analysis of α-syn in blood. The comparison discloses the advantages and disadvantages of AA-SPE-MS for the rapid and sensitive targeted analysis of protein biomarkers in biological fluids.
Collapse
|
6
|
Hu W, Zhou W, Wang C, Liu Z, Chen Z. Direct coupling in-tube solid-phase microextraction with mass spectrometry using polymer coated open-tubular column for rapid analysis of antiepileptic drugs in biofluids. Anal Chim Acta 2023; 1240:340775. [PMID: 36641145 DOI: 10.1016/j.aca.2022.340775] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 12/25/2022] [Accepted: 12/30/2022] [Indexed: 12/31/2022]
Abstract
Development of high-throughput and rapid screening analytical method is in high demand for anti-doping and clinical point-of-care (POC) analysis. Solid-phase microextraction and mass spectrometry direct coupling (SPME-MS) has been proved as a rapid and effective way for target analysis in complex sample matrixes. An online direct coupling of in-tube SPME (IT-SPME) with MS using polymer coated open-tubular column has been developed in this work. A sharp stainless-steel needle was attached at the end of the SPME column, which enables the direct ionization of the analytes after elution from the IT-SPME column. Itaconic acid-benzene co-polymer was in-situ grown on the inner surface of the fused silica capillary and used as extraction phase. This column has low backpressure and provides both hydrophobic and weak cationic exchange interaction with the target analytes due to the chemical properties. The developed online IT-SPME-MS method showed good extraction performance towards various target analytes and good reusability at least for 60 times. As a proof-of-concept application, the above method was applied for the analysis of antiepileptic drugs (AEDs) in both plasma and urine samples with linear range (1 ng/mL-200 ng/mL), good linearity (R2 ≥ 0.99), and good reproducibility (intra-day RSDs less than 4.36%, inter-day RSDs less than 6.55%). The method exhibited high enrichment factors between 187 and 204 for the two AEDs and high sensitivity for the analysis of human plasma samples and urine samples.
Collapse
Affiliation(s)
- Wei Hu
- Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, School of Pharmaceutical Sciences, Wuhan University, Wuhan, 430072, China; Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, Hubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticals, Wuhan, 430071, China
| | - Wei Zhou
- Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, School of Pharmaceutical Sciences, Wuhan University, Wuhan, 430072, China
| | - Chenlu Wang
- Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, School of Pharmaceutical Sciences, Wuhan University, Wuhan, 430072, China
| | - Zichun Liu
- Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, School of Pharmaceutical Sciences, Wuhan University, Wuhan, 430072, China
| | - Zilin Chen
- Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, School of Pharmaceutical Sciences, Wuhan University, Wuhan, 430072, China; Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, Hubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticals, Wuhan, 430071, China.
| |
Collapse
|
7
|
Zhou W, Pawliszyn J. Coated Blade Spray with a Barrier: Improving Negative Electrospray Ionization and Sample Preparation. Anal Chem 2022; 94:15879-15886. [DOI: 10.1021/acs.analchem.2c04003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, OntarioN2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, OntarioN2L 3G1, Canada
| |
Collapse
|
8
|
Rankin‐Turner S, Reynolds JC, Turner MA, Heaney LM. Applications of ambient ionization mass spectrometry in 2021: An annual review. ANALYTICAL SCIENCE ADVANCES 2022; 3:67-89. [PMID: 38715637 PMCID: PMC10989594 DOI: 10.1002/ansa.202100067] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 02/17/2022] [Accepted: 02/27/2022] [Indexed: 06/26/2024]
Abstract
Ambient ionization mass spectrometry (AIMS) has revolutionized the field of analytical chemistry, enabling the rapid, direct analysis of samples in their native state. Since the inception of AIMS almost 20 years ago, the analytical community has driven the further development of this suite of techniques, motivated by the plentiful advantages offered in addition to traditional mass spectrometry. Workflows can be simplified through the elimination of sample preparation, analysis times can be significantly reduced and analysis remote from the traditional laboratory space has become a real possibility. As such, the interest in AIMS has rapidly spread through analytical communities worldwide, and AIMS techniques are increasingly being integrated with standard laboratory operations. This annual review covers applications of AIMS techniques throughout 2021, with a specific focus on AIMS applications in a number of key fields of research including disease diagnostics, forensics and security, food safety testing and environmental sciences. While some new techniques are introduced, the focus in AIMS research is increasingly shifting from the development of novel techniques toward efforts to improve existing AIMS techniques, particularly in terms of reproducibility, quantification and ease-of-use.
Collapse
Affiliation(s)
- Stephanie Rankin‐Turner
- W. Harry Feinstone Department of Molecular Microbiology and ImmunologyJohns Hopkins Bloomberg School of Public HealthJohns Hopkins UniversityBaltimoreMarylandUSA
| | - James C. Reynolds
- Department of ChemistryLoughborough UniversityLoughboroughLeicestershireUK
| | - Matthew A. Turner
- Department of ChemistryLoughborough UniversityLoughboroughLeicestershireUK
| | - Liam M. Heaney
- School of SportExercise and Health SciencesLoughborough UniversityLoughboroughLeicestershireUK
| |
Collapse
|