1
|
Han L, Wang X, Yu B, Qin X, Liu B, Han X, Yuan H, Yu B, Zhao Z. Development of Fe 3O 4/DEX/PDA@Au(Raman reporters)@Au-MPBA nanocomposites based multi-hotspot SERS probe for ultrasensitive, reliable, and quantitative detection of glucose in sweat. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2025; 326:125192. [PMID: 39342716 DOI: 10.1016/j.saa.2024.125192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Revised: 09/16/2024] [Accepted: 09/22/2024] [Indexed: 10/01/2024]
Abstract
Glucose is a key biomarker of diabetes, and effective glucose monitoring methods are crucial to the prevention and management of diabetes. Therefore, in this paper, Fe3O4/DEX/PDA@Au (Raman reporters) @Au nanocomposites were synthetized that with DTNB (5,5'-dithiobis(2-nitrobenzoic)), MMTA (2-mercapto-4-methyl-5-thiazole acetic acid), MBA (4-mercaptobenzoic acid) and 4-Mpy(4-Mercaptopyridine) were used separately as Raman reporters. Fe3O4 and PDA (Polymerized dopamine) could supply more high surface area of active sites and high SERS (Surface-Enhanced Raman Scattering) substrate, which has high stability and reproducibility. Dextran coating is an effective way to prepare biocompatible materials TEM, XRD, TG and VSM were used to analyze the size, morphology and magnetic properties of the nanocomposites. Fe3O4/DEX/PDA@Au(Raman reporters)@Au that integrates a multi-hotspot structure and magnetic separation techniques were studied the enhancement effect of Raman spectra, and glucose solutions with different concentrations were tested. Furthermore, the optimal Fe3O4/DEX/PDA@Au(Raman reporters)@Au nanocomposites were supplied as SERS substrates for detection of glucose accurately and quickly in sweat. SERS signal intensity is linearly correlated with glucose concentration within the measurement range of 5 × 10-3 to 10 mM, and the minimum detectable concentration is 5 µM. The Fe3O4/DEX/PDA@Au(Raman reporters)@Au nanocomposites exhibit high reliability, specificity and repeatability of the strategy were then verified by practical detection of sweat.
Collapse
Affiliation(s)
- Lun Han
- School of Textile and Garment, Anhui Polytechnic University, Wuhu, Anhui 241000, China.
| | - Xu Wang
- School of Textile and Garment, Anhui Polytechnic University, Wuhu, Anhui 241000, China; Guangzhou Jingwei Jinfang Protection Technology Co., Ltd, Guangzhou 510000, China
| | - Bin Yu
- Department of Supply Management, Naval Logistics Academy, Tianjin 300000, China
| | - Xiaoyuan Qin
- School of Textile and Garment, Anhui Polytechnic University, Wuhu, Anhui 241000, China
| | - Baocheng Liu
- Guangzhou Jingwei Jinfang Protection Technology Co., Ltd, Guangzhou 510000, China
| | - Xu Han
- School of Textile and Garment, Anhui Polytechnic University, Wuhu, Anhui 241000, China
| | - Huifen Yuan
- School of Textile and Garment, Anhui Polytechnic University, Wuhu, Anhui 241000, China
| | - Bin Yu
- School of Textile, Henan University of Engineering, Zhengzhou 450000, Henan, China
| | - Zhiqi Zhao
- School of Textile and Garment, Anhui Polytechnic University, Wuhu, Anhui 241000, China.
| |
Collapse
|
2
|
Zhou S, Qiu P, Feng R, Zhang J, Su Z, Bai Y, He J. Magnetic field facilitated-colorimetric aptasensor for selective and sensitive detection of Staphylococcus aureus using aptamer-labeled Zn/Co ICPs nanoenzyme. Talanta 2025; 287:127633. [PMID: 39884119 DOI: 10.1016/j.talanta.2025.127633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2024] [Revised: 01/21/2025] [Accepted: 01/23/2025] [Indexed: 02/01/2025]
Abstract
Colorimetric detection of pathogenic bacteria (such as S. aureus) in complex sample confronts challenges regarding sensitivity, selectivity, and accuracy. In this paper, a magnetic field facilitated (MFF)-colorimetric aptasensor was proposed for S. aureus detection based on magnetic separation and nanoenzyme-facilitated chromogenic reaction. The vancomycin-functionalized magnetic chitosan (CS-MNPs-Van) was introduced to capture and isolate S. aureus from the complex matrix through magnetic field separation. The zinc/cobalt infinite coordination polymers (Zn/Co ICPs) was rapidly prepared with a green synthesis technology at room temperature. It was directly functionalized with aptamer through interactions of Zn2+/Co2+ and phosphate backbone, large surface area and π-π stacking reactions, avoiding the tedious chemical modification. The aptamer-labeled Zn/Co ICPs (Zn/Co ICPs-Apt) exhibited not only the excellent peroxidase-like activity, but also the good specificity toward the captured S. aureus to generate CS-MNPs-Van@S. aureus@Zn/Co ICPs-Apt complexes. The residual unreacted Zn/Co ICPs-Apt catalyzed the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) to produce blue oxTMB, which can be distinguished with naked eyes. The S. aureus concentration showed a negative correlation with the absorbance (A652 nm) in the range of 1.8 × 101 to 1.8 × 10⁵ CFU/mL, with a detection limit of 4 CFU/mL. The MFF-colorimetric aptasensor presents advantages of high sensitivity, good selectivity, low matrix interference and naked visualization without complicated devices, making it competitive candidate for on-site and large-scale detection of pathogens.
Collapse
Affiliation(s)
- Siwei Zhou
- School of Public Health, Guangdong Pharmaceutical University, Guangzhou, 510310, China
| | - Peipei Qiu
- School of Public Health, Guangdong Pharmaceutical University, Guangzhou, 510310, China
| | - Ruihua Feng
- School of Public Health, Guangdong Pharmaceutical University, Guangzhou, 510310, China
| | - Junhe Zhang
- School of Public Health, Guangdong Pharmaceutical University, Guangzhou, 510310, China
| | - Zhengquan Su
- Guangdong Engineering Research Center of Natural Products and New Drugs, Guangdong Pharmaceutical University, Guangzhou, 510006, China.
| | - Yan Bai
- School of Public Health, Guangdong Pharmaceutical University, Guangzhou, 510310, China.
| | - Jincan He
- School of Public Health, Guangdong Pharmaceutical University, Guangzhou, 510310, China.
| |
Collapse
|
3
|
Chen D, Ma Y, Yang A, Hu L, Zhou H, Xu J, Chen S, Nie D, Feng W, Cai H, Cong Y, Pi J, Rao L, Huang X, Sun P, Zhou H. Dual-Enhanced SERS Satellite Immuno-Nanocomplex for Multiple PSA-Mediated PHI Assay Toward Clinical Prostate Cancer Screening. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024:e2411747. [PMID: 39656930 DOI: 10.1002/advs.202411747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2024] [Revised: 11/21/2024] [Indexed: 12/17/2024]
Abstract
Prostate specific antigen (PSA) is widely used in liquid biopsy of prostate cancer (PCa) but still faces challenges due to the poor specificity. Herein, this study reports a double-SERS satellite immunoassay, made of an Au-Ag dealloyed intra-nanogap nanoflower (Au-Ag DINF) with strong SERS signals and Au magnetic nanoparticles (AuMNPs) with magnetic capture and SERS amplification, for sensing multiple PSA (free PSA (fPSA), complexed PSA (cPSA) and [-2]proPSA (p2PSA)) toward potential PCa screening. Unlike the previous studies focus on the tPSA and fPSA/tPSA ratio (f/t PSA%), this work introduces a multiple PSA-mediated Prostate Health Index (PHI) assay with significantly increased the predictive accuracy and specificity of PCa, especially the patients with a tPSA level in the "diagnostic gray zone". Practical analysis of clinical samples demonstrated the SERS immunoassay is capable of identifying the PCa subjects from healthy candidates (N = 13), and monitoring PCa patients before and after surgery (N = 5), as well as screening suspicious ones who are in the "gray zone" (N = 10). Overall, benefiting from the PSA-responsive satellite immuno-nanoassemble strategy, dual-SERS magnification effect, and multiple PSA-based PHI assessment, this proposes bioassay held enormous potential for the early diagnosis, screening, monitoring, and prognosis of PCa.
Collapse
Affiliation(s)
- Dong Chen
- Institute for Safflower Industry Research, Key Laboratory of Xinjiang Phytomedicine Resource and Utilization (Ministry of Education), School of Pharmacy, Shihezi University, Shihezi, 832003, China
- Department of Urology, State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, 510060, China
| | - Yilin Ma
- Institute for Safflower Industry Research, Key Laboratory of Xinjiang Phytomedicine Resource and Utilization (Ministry of Education), School of Pharmacy, Shihezi University, Shihezi, 832003, China
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou, 510632, China
| | - Annan Yang
- Institute for Safflower Industry Research, Key Laboratory of Xinjiang Phytomedicine Resource and Utilization (Ministry of Education), School of Pharmacy, Shihezi University, Shihezi, 832003, China
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou, 510632, China
| | - Liping Hu
- Institute for Safflower Industry Research, Key Laboratory of Xinjiang Phytomedicine Resource and Utilization (Ministry of Education), School of Pharmacy, Shihezi University, Shihezi, 832003, China
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou, 510632, China
| | - Hanlin Zhou
- Institute for Safflower Industry Research, Key Laboratory of Xinjiang Phytomedicine Resource and Utilization (Ministry of Education), School of Pharmacy, Shihezi University, Shihezi, 832003, China
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou, 510632, China
| | - Jun Xu
- Institute for Safflower Industry Research, Key Laboratory of Xinjiang Phytomedicine Resource and Utilization (Ministry of Education), School of Pharmacy, Shihezi University, Shihezi, 832003, China
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou, 510632, China
| | - Shanze Chen
- Institute for Safflower Industry Research, Key Laboratory of Xinjiang Phytomedicine Resource and Utilization (Ministry of Education), School of Pharmacy, Shihezi University, Shihezi, 832003, China
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou, 510632, China
| | - Dingmeng Nie
- Institute of Chemical Biology, Shenzhen Bay Laboratory, Shenzhen, 518132, China
| | - Weifeng Feng
- The First Affiliated Hospital of Jinan University, Guangzhou, 510632, China
| | - Huaihong Cai
- College of Chemistry and Materials Science, Jinan University, Guangzhou, 510632, China
| | - Yanguang Cong
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, School of Medical Technology, Guangdong Medical University, Dongguan, 523000, China
| | - Jiang Pi
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, School of Medical Technology, Guangdong Medical University, Dongguan, 523000, China
| | - Lang Rao
- Institute of Chemical Biology, Shenzhen Bay Laboratory, Shenzhen, 518132, China
| | - Xueqin Huang
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, School of Medical Technology, Guangdong Medical University, Dongguan, 523000, China
| | - Pinghua Sun
- Institute for Safflower Industry Research, Key Laboratory of Xinjiang Phytomedicine Resource and Utilization (Ministry of Education), School of Pharmacy, Shihezi University, Shihezi, 832003, China
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou, 510632, China
| | - Haibo Zhou
- Institute for Safflower Industry Research, Key Laboratory of Xinjiang Phytomedicine Resource and Utilization (Ministry of Education), School of Pharmacy, Shihezi University, Shihezi, 832003, China
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou, 510632, China
| |
Collapse
|
4
|
Wang Z, Ma N, Zhang J, Ma K, Kong J, Zhang X. Bacteria-instructed synthesis of free radical polymers for highly sensitive detection of Escherichia coli and Staphylococcus aureus. Anal Chim Acta 2024; 1329:343259. [PMID: 39396316 DOI: 10.1016/j.aca.2024.343259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2024] [Accepted: 09/17/2024] [Indexed: 10/15/2024]
Abstract
BACKGROUND Foodborne pathogens such as Escherichia coli and Staphylococcus aureus commonly found in food and water sources are the leading causes of foodborne disease outbreaks, which have become a worldwide issue that can lead to serious health problems and socio-economic losses. Therefore, the development of accurate and timely detection methods for these bacteria is essential to safeguard public health and food safety. However, due to the drawbacks of conventional detection methods such as complex operation, high cost, low specificity and sensitivity, developing efficient and sensitive techniques remains a challenge. RESULTS In this study, we developed a fluorescent biosensor based on bacteria-instructed atom transfer radical polymerization (ATRP) for ultrasensitive and specific detection of foodborne pathogenic bacteria. This approach first attaches initiators of ATRP to the surface of carboxylated Fe3O4 magnetic beads via transition metal and subsequently utilizes the distinctive copper-binding redox pathway of bacteria to reduce Cu(II) to Cu(I), which activates the surface-initiated polymerization for in situ growth of fluorescent polymer. This signal amplification strategy significantly enhanced the sensitivity of fluorescence analysis performance. Under optimal conditions, there was a perfect linear correlation between the fluorescence signal intensity and the logarithm of the concentrations of S. aureus and E. coli over the range from 103 CFU/mL to 108 CFU/mL, with the detection limits down to 102 CFU/mL for both. SIGNIFICANCE The fluorescent biosensor provides an efficient, sensitive and stable solution for the direct detection of S. aureus/E. coli, confirming the feasibility of the bacterial-instructed ATRP reaction as a signal amplification strategy. This detection method does not require the help of any external stimuli or complex equipment. Moreover, it shows great potential for application in detecting pathogenic bacteria in complex food samples.
Collapse
Affiliation(s)
- Zhengjun Wang
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu, 210094, PR China
| | - Nan Ma
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu, 210094, PR China
| | - Jian Zhang
- Nanjing Lishui District Hospital of Traditional Chinese Medicine, Nanjing, 211200, PR China; Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, 210028, PR China
| | - Kefeng Ma
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu, 210094, PR China
| | - Jinming Kong
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu, 210094, PR China.
| | - Xueji Zhang
- School of Biomedical Engineering, Shenzhen University Health Science Center, Shenzhen, Guangdong, 518060, PR China
| |
Collapse
|
5
|
Dong Z, Liu X, Zhou S, Zhu Y, Chen J, Liu Y, Ren X, Lu YQ, Xiao R, Wang G. Microsphere lens array embedded microfluidic chip for SERS detection with simultaneous enhancement of sensitivity and stability. Biosens Bioelectron 2024; 261:116505. [PMID: 38885536 DOI: 10.1016/j.bios.2024.116505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 05/25/2024] [Accepted: 06/15/2024] [Indexed: 06/20/2024]
Abstract
Surface enhanced Raman spectroscopy (SERS) utilizes the fingerprint features of molecular vibrations to identify and detect substances. However, in traditional single focus excitation scenarios, its signal collection efficiency of the objective is restricted. Furthermore, the uneven distribution of samples on the SERS substrate would result in poor signal stability, while the excitation power is limited to avoid sample damage. SERS detection system always requires precise adjustment of focal length and spot size, making it difficult for point-of-care testing applications. Here, we proposed a SERS microfluidic chip with barium titanate microspheres array (BTMA) embedded using vacuum self-assembled hot-pressing method for SERS detection with simultaneous enhancement of sensitivity and stability. Due to photonic nano-jets and directional antenna effects, high index microspheres are perfect micro-lens for effective light focusing and signal collecting. The BTMA can not only disperse excitation beam into an array of focal points covering the target uniformly with very low signal fluctuation, but enlarge the power threshold for higher signal intensity. We conducted a proof-of-principle experiment on chip for the detection of bacteria with immuno-magnetic tags and immuno-SERS tags. Together with magnetic and ultrasonic operations, the target bacteria in the flow were evenly congregated on the focal plane of BTMA. It demonstrated a limit of detection of 5 cells/mL, excellent signal reproducibility (error∼4.84%), and excellent position tolerance of 500 μm in X-Y plane (error∼5.375%). It can be seen that BTMA-SERS microfluidic chip can effectively solve the contradiction between sensitivity and stability in SERS detection.
Collapse
Affiliation(s)
- Zhenyong Dong
- College of Engineering and Applied Sciences, Nanjing University, Nanjing, 210093, PR China; Key Laboratory of Intelligent Optical Sensing and Integration of the Ministry of Education, Nanjing University, Nanjing, 210009, PR China
| | - Xiaoxian Liu
- College of Engineering and Applied Sciences, Nanjing University, Nanjing, 210093, PR China; Key Laboratory of Intelligent Optical Sensing and Integration of the Ministry of Education, Nanjing University, Nanjing, 210009, PR China; State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Song Zhou
- Jiangsu Key Laboratory of Advanced Manufacturing Technology, Faculty of Mechanical and Material Engineering, Huaiyin Institute of Technology, Huai'an, 223003, PR China
| | - Yifan Zhu
- College of Engineering and Applied Sciences, Nanjing University, Nanjing, 210093, PR China; Key Laboratory of Intelligent Optical Sensing and Integration of the Ministry of Education, Nanjing University, Nanjing, 210009, PR China
| | - Jin Chen
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Yukai Liu
- College of Engineering and Applied Sciences, Nanjing University, Nanjing, 210093, PR China; Key Laboratory of Intelligent Optical Sensing and Integration of the Ministry of Education, Nanjing University, Nanjing, 210009, PR China
| | - Xiao Ren
- College of Engineering and Applied Sciences, Nanjing University, Nanjing, 210093, PR China; Key Laboratory of Intelligent Optical Sensing and Integration of the Ministry of Education, Nanjing University, Nanjing, 210009, PR China
| | - Yan-Qing Lu
- College of Engineering and Applied Sciences, Nanjing University, Nanjing, 210093, PR China.
| | - Rui Xiao
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China.
| | - Guanghui Wang
- College of Engineering and Applied Sciences, Nanjing University, Nanjing, 210093, PR China; Key Laboratory of Intelligent Optical Sensing and Integration of the Ministry of Education, Nanjing University, Nanjing, 210009, PR China; Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, PR China.
| |
Collapse
|
6
|
Zhang X, Wang X, Shi B, Li J, Fan Y, Li Y, Shi C, Ma C. A biphasic accelerated strand exchange amplification strategy for culture-independent and rapid detection of Salmonella enterica in food samples. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:4083-4092. [PMID: 38855899 DOI: 10.1039/d4ay00613e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2024]
Abstract
Salmonella enterica is a common foodborne pathogen that can cause food poisoning in humans. The organism also infects and causes disease in animals. Rapid and sensitive detection of S. enterica is essential to prevent the spread of this pathogen. Traditional technologies for the extraction and detection of this pathogen from complex food matrices are cumbersome and time-consuming. In this study, we introduced a novel strategy of biphasic assay integrated with an accelerated strand exchange amplification (ASEA) method for efficient detection of S. enterica without culture or other extraction procedures. Food samples are rapidly dried, resulting in a physical fluidic network inside the dried food matrix, which allows polymerases and primers to access the target DNA and initiate ASEA. The dried food matrix is defined as the solid phase, while amplification products are enriched in the supernatant (liquid phase) and generate fluorescence signals. The analytical performances demonstrated that this strategy was able to specifically identify S. enterica and did not show any cross-reaction with other common foodborne pathogens. For artificially spiked food samples, the strategy can detect 5.0 × 101 CFU mL-1S. enterica in milk, 1.0 × 102 CFU g-1 in duck, scallop or lettuce, and 1.0 × 103 CFU g-1 in either oyster or cucumber samples without pre-enrichment of the target pathogen. We further validated the strategy using 82 real food samples, and this strategy showed 92% sensitivity. The entire detection process can be finished, sample-to-answer, within 50 min, dramatically decreasing the detection time. Therefore, we believe that the proposed method enables rapid and sensitive detection of S. enterica and holds great promise for the food safety industry.
Collapse
Affiliation(s)
- Xiaojun Zhang
- Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China.
| | - Xiujuan Wang
- Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China.
| | - Binghui Shi
- Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China.
| | - Junfeng Li
- Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China.
| | - Yaofang Fan
- Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China.
| | - Yong Li
- Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China.
| | - Chao Shi
- Qingdao Nucleic Acid Rapid Testing International Science and Technology Cooperation Base, College of Life Sciences, Department of Pathogenic Biology, School of Basic Medicine, Department of Clinical Laboratory, The Affiliated Hospital of Qingdao University, Qingdao University, Qingdao, 266071, PR China
| | - Cuiping Ma
- Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China.
| |
Collapse
|
7
|
Awais M, Naqvi SMZA, Wei Z, Wu J, Arshad I, Raghavan V, Khan SU, Hu J. Functionalized Single Crystal Perovskite Materials for SERS and Their Potential Detection Applications. J Fluoresc 2024:10.1007/s10895-024-03716-7. [PMID: 38613710 DOI: 10.1007/s10895-024-03716-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Accepted: 04/08/2024] [Indexed: 04/15/2024]
Abstract
Recent advances in detection and diagnostic tools have improved understanding and identification of plant physiological and biochemical processes. Effective and safe Surface Enhanced Raman Spectroscopy (SERS) can find objects quickly and accurately. Raman enhancement amplifies the signal by 1014-1015 to accurately quantify plant metabolites at the molecular level. This paper shows how to use functionalized perovskite substrates for SERS. These perovskite substrates have lots of surface area, intense Raman scattering, and high sensitivity and specificity. These properties eliminate sample matrix component interference. This study identified research gaps on perovskite substrates' effectiveness, precision, and efficiency in biological metabolite detection compared to conventional substrates. This article details the synthesis and use of functionalized perovskites for plant metabolites measurement. It analyzes their pros and cons in this context. The manuscript analyzes perovskite-based SERS substrates, including single-crystalline perovskites with enhanced optoelectronic properties. This manuscript aims to identify this study gap by comprehensively reviewing the literature and using it to investigate plant metabolite detection in future studies.
Collapse
Affiliation(s)
- Muhammad Awais
- Department of Mechanical and Electrical Engineering, Henan Agricultural University, Zhengzhou, 450002, China
- Henan International Joint Laboratory of Laser Technology in Agriculture Sciences, Zhengzhou, 450002, China
- State Key Laboratory of Wheat and Maize Crop Science, Zhengzhou, 450002, China
| | - Syed Muhammad Zaigham Abbas Naqvi
- Department of Mechanical and Electrical Engineering, Henan Agricultural University, Zhengzhou, 450002, China.
- Henan International Joint Laboratory of Laser Technology in Agriculture Sciences, Zhengzhou, 450002, China.
- State Key Laboratory of Wheat and Maize Crop Science, Zhengzhou, 450002, China.
| | - Zhang Wei
- Department of Mechanical and Electrical Engineering, Henan Agricultural University, Zhengzhou, 450002, China
- Henan International Joint Laboratory of Laser Technology in Agriculture Sciences, Zhengzhou, 450002, China
- State Key Laboratory of Wheat and Maize Crop Science, Zhengzhou, 450002, China
| | - Junfeng Wu
- Department of Mechanical and Electrical Engineering, Henan Agricultural University, Zhengzhou, 450002, China
- Henan International Joint Laboratory of Laser Technology in Agriculture Sciences, Zhengzhou, 450002, China
- State Key Laboratory of Wheat and Maize Crop Science, Zhengzhou, 450002, China
| | - Ifzan Arshad
- Institute for Advanced Study, Shenzhen University, Shenzhen, 518060, Guangdong, China
- College of Civil and Transportation Engineering, Shenzhen University, Shenzhen, China
| | - Vijaya Raghavan
- Department of Bioresource Engineering, Faculty of Agriculture and Environmental Studies, McGill University, Sainte-Anne-de-Bellevue, Quebec, H9X 3V9, Canada
| | - Sami Ullah Khan
- Department of Mathematics, Namal University, Talagang Road, Mianwali, 42250, Pakistan
| | - Jiandong Hu
- Department of Mechanical and Electrical Engineering, Henan Agricultural University, Zhengzhou, 450002, China.
- Henan International Joint Laboratory of Laser Technology in Agriculture Sciences, Zhengzhou, 450002, China.
- State Key Laboratory of Wheat and Maize Crop Science, Zhengzhou, 450002, China.
| |
Collapse
|
8
|
Zhou S, Huang P, Cao Y, Hua X, Yang Y, Liu S. Garlic-Derived Exosome-like Nanovesicles-Based Wound Dressing for Staphylococcus aureus Infection Visualization and Treatment. ACS APPLIED BIO MATERIALS 2024; 7:1888-1898. [PMID: 38349328 DOI: 10.1021/acsabm.3c01256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/19/2024]
Abstract
Garlic-derived exosome-like nanovesicles (GELNs) could function in interspecies communication and may serve as natural therapeutics to regulate the inflammatory response or as nanocarriers to efficiently deliver specific drugs. Staphylococcus aureus (S. aureus) is able to hide within host cells to evade immune clearance and antibiotics, leading to life-threatening infections. On-site detection and efficient treatment of intracellular S. aureus infection in wounds remain challenging. Herein, we report a thermosensitive, injectable, visible GELNs-based wound dressing, Van@GELNs/F127 hydrogel (gel Van@GELNs), which is H2O2-responsive and can slowly release vancomycin into host cells forS. aureus infection visualization and treatment in wounds. GELNs show inherent antibacterial activity, which is significantly enhanced after loading vancomycin. Both GELNs and Van@GELNs have the ability to be internalized by cells, so Van@GELNs are more effective than free vancomycin in killing S. aureus in RAW 264.7 macrophages. When applied to an S. aureus-infected wound on a mouse, the colorless HRP&ABTS/Van@GELNs/F127 solution immediately changes to a green hydrogel and shows better therapeutic effect than vancomycin. Thus, direct visualization by the naked eye and effective treatment of S. aureus infection in wounds are achieved by gel Van@GELNs. We anticipate gel Van@GELNs be applied for the theranostics of S. aureus infection diseases in the clinic in the near future.
Collapse
Affiliation(s)
- Sisi Zhou
- Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Puzhen Huang
- Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Yu Cao
- Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Xin Hua
- Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Yao Yang
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Songqin Liu
- Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| |
Collapse
|
9
|
Wu J, Li S, Ma Y, Zhi W, Chen T, Huang X, Huang C, Zhou X, Zhang P, Zhang Y, Zheng G, Wang Z, Zhong X, Cai H, Wang W, Sun P, Zhou H. 3D hierarchic interfacial assembly of Au nanocage@Au along with IS-AgMNPs for simultaneous, ultrasensitive, reliable, and quantitative SERS detection of colorectal cancer related miRNAs. Biosens Bioelectron 2024; 248:115993. [PMID: 38183788 DOI: 10.1016/j.bios.2023.115993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 12/22/2023] [Accepted: 12/28/2023] [Indexed: 01/08/2024]
Abstract
Simultaneous, reliable, and ultra-sensitive analysis of promising miRNA biomarkers of colorectal cancer (CRC) in serum is critical for early diagnosis and prognosis of CRC. In this work, we proposed a novel 3D hierarchic assembly clusters-based SERS strategy with dual enrichment and enhancement designed for the ultrasensitive and quantitative analysis of two upregulated CRC-related miRNAs (miR-21 and miR-31). The biosensor contains the following: (1) SERS probe, Au nanocage@Au nanoparticles (AuNC@Au NPs) labeled with Raman reporters (RaRs). (2) magnetic capture unit, Ag-coated Fe3O4 magnetic nanoparticles (AgMNPs) modified with internal standard (IS). (3) signal amplify probes (SA probes) for the formation of hierarchic assembly clusters. Based on this sensing strategy, the intensity ratio IRaRs/IIS with Lg miRNAs presents a wide linear range (10 aM-100 pM) with a limit of detection of 3.46 aM for miR-21, 6.49 aM for miR-31, respectively. Moreover, the biosensor shows good specificity and anti-interference ability, and the reliability and repeatability of the strategy were then verified by practical detection of clinical serum. Finally, the biosensor can distinguish CRC cancer subjects from normal ones and guide the distinct tumor, lymph node, and metastasis (TNM) stages. Overall, benefiting from the face-to-face coupling of hierarchic assembly clusters, rapid magnetic enrichment and IS signal calibration of AgMNPs, the established biosensor achieves ultra-sensitive and simultaneous detection of dual miRNAs and opens potential avenues for prediction and staging of CRC.
Collapse
Affiliation(s)
- Jiamin Wu
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou 510632, China
| | - Shengrong Li
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou 510632, China
| | - Yiling Ma
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou 510632, China
| | - Weixia Zhi
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou 510632, China
| | - Tingting Chen
- College of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China
| | - Xueqin Huang
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou 510632, China
| | - Chan Huang
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou 510632, China
| | - Xia Zhou
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou 510632, China
| | - Pengcheng Zhang
- College of Chemistry and Chemical Engineering, Zhoukou Normal University, Zhoukou 466001, China
| | - Yuan Zhang
- School of Physics and Microelectronics, Zhengzhou University, Zhengzhou 450052, China
| | - Guangchao Zheng
- School of Physics and Microelectronics, Zhengzhou University, Zhengzhou 450052, China
| | - Zhigang Wang
- The First Affiliated Hospital of Jinan University, Guangzhou 510630, China
| | - Xing Zhong
- The First Affiliated Hospital of Jinan University, Guangzhou 510630, China
| | - Huaihong Cai
- College of Chemistry and Materials Science, Jinan University, Guangzhou 510632, China
| | - Wenxia Wang
- College of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China.
| | - Pinghua Sun
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou 510632, China.
| | - Haibo Zhou
- College of Pharmacy, The Second Clinical Medical College (Shenzhen People's Hospital), The Fifth Affiliated Hospital, Jinan University, Guangzhou 510632, China.
| |
Collapse
|
10
|
Xie M, Zhu Y, Li Z, Yan Y, Liu Y, Wu W, Zhang T, Li Z, Wang H. Key steps for improving bacterial SERS signals in complex samples: Separation, recognition, detection, and analysis. Talanta 2024; 268:125281. [PMID: 37832450 DOI: 10.1016/j.talanta.2023.125281] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 09/09/2023] [Accepted: 10/05/2023] [Indexed: 10/15/2023]
Abstract
Rapid and reliable detection of pathogenic bacteria is absolutely essential for research in environmental science, food quality, and medical diagnostics. Surface-enhanced Raman spectroscopy (SERS), as an emerging spectroscopic technique, has the advantages of high sensitivity, good selectivity, rapid detection speed, and portable operation, which has been broadly used in the detection of pathogenic bacteria in different kinds of complex samples. However, the SERS detection method is also challenging in dealing with the detection difficulties of bacterial samples in complex matrices, such as interference from complex matrices, confusion of similar bacteria, and complexity of data processing. Therefore, researchers have developed some technologies to assist in SERS detection of bacteria, including both the front-end process of obtaining bacterial sample data and the back-end data processing process. The review summarizes the key steps for improving bacterial SERS signals in complex samples: separation, recognition, detection, and analysis, highlighting the principles of each step and the key roles for SERS pathogenic bacteria analysis, and the interconnectivity between each step. In addition, the current challenges in the practical application of SERS technology and the development trends are discussed. The purpose of this review is to deepen researchers' understanding of the various stages of using SERS technology to detect bacteria in complex sample matrices, and help them find new breakthroughs in different stages to facilitate the detection and control of bacteria in complex samples.
Collapse
Affiliation(s)
- Maomei Xie
- College of Pharmaceutical Engineering of Traditional Chinese Medicine (TCM), Tianjin University of TCM, Tianjin, 301617, China
| | - Yiting Zhu
- College of Pharmaceutical Engineering of Traditional Chinese Medicine (TCM), Tianjin University of TCM, Tianjin, 301617, China
| | - Zhiyao Li
- College of Pharmaceutical Engineering of Traditional Chinese Medicine (TCM), Tianjin University of TCM, Tianjin, 301617, China
| | - Yueling Yan
- College of Pharmaceutical Engineering of Traditional Chinese Medicine (TCM), Tianjin University of TCM, Tianjin, 301617, China
| | - Yidan Liu
- College of Pharmaceutical Engineering of Traditional Chinese Medicine (TCM), Tianjin University of TCM, Tianjin, 301617, China
| | - Wenbo Wu
- College of Pharmaceutical Engineering of Traditional Chinese Medicine (TCM), Tianjin University of TCM, Tianjin, 301617, China
| | - Tong Zhang
- College of Pharmaceutical Engineering of Traditional Chinese Medicine (TCM), Tianjin University of TCM, Tianjin, 301617, China
| | - Zheng Li
- College of Pharmaceutical Engineering of Traditional Chinese Medicine (TCM), Tianjin University of TCM, Tianjin, 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin, 301617, China; State Key Laboratory of Component-based Chinese Medicine, Tianjin University of TCM, Tianjin, 301617, China.
| | - Haixia Wang
- College of Pharmaceutical Engineering of Traditional Chinese Medicine (TCM), Tianjin University of TCM, Tianjin, 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin, 301617, China; State Key Laboratory of Component-based Chinese Medicine, Tianjin University of TCM, Tianjin, 301617, China.
| |
Collapse
|
11
|
Mia AK, Bora A, Hossain MT, Sinha S, Giri PK. Fast detection of Staphylococcus aureus using thiol-functionalized WS 2 quantum dots and Bi 2O 2Se nanosheets hybrid through a fluorescence recovery mechanism. J Mater Chem B 2023; 11:10206-10217. [PMID: 37853818 DOI: 10.1039/d3tb01465g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2023]
Abstract
Ultrafast and sensitive detection of Staphylococcus aureus (S. aureus), a harmful Gram-positive human pathogenic bacterium, by two-dimensional layered materials continues to be a challenge. Herein, we have studied the sensing of S. aureus using a tungsten disulfide (WS2) quantum dot (QD) and bismuth oxyselenide (Bi2O2Se) nanosheet (NS) hybrid through their unique optical functionalities. The WS2 QDs of a mean diameter of 2.5 nm were synthesized by liquid exfoliation. Due to the quantum confinement and functional groups, the WS2 QDs exhibit high fluorescence (FL) yield under UV excitation. The addition of Bi2O2Se NSs resulted in the adsorption of WS2 QDs on their surface, resulting in quenching of the FL emission due to nonfluorescent complex formation between the WS2 QDs and Bi2O2Se NSs. A specific sequencing single-standard DNA (ssDNA) aptamer, which identifies and explicitly binds with S. aureus, was attached to the defect sites of the WS2 QDs for selective detection. The thiol-modified ssDNA aptamers attach covalently to the WS2 QD defect sites, which was confirmed by Raman and X-ray photoelectron spectroscopy (XPS). The interaction of S. aureus with the aptamer functionalized WS2 QDs weakens the van der Waals interaction between the WS2 QDs and Bi2O2Se NSs, which results in the detachment of the WS2 QDs from the Bi2O2Se NS surface and restores the FL intensity of the WS2 QDs, thus allowing the efficient detection of S. aureus. Similar measurements with non-targeted bacteria show that the system is quite selective towards S. aureus. Our FL-based biosensor has a linear response in the range of 103-107 CFU mL-1 (colony formation unit mL-1) with a detection limit of 580 CFU mL-1. We have observed a fast response time of 15 minutes for sensing, which is superior to the previous reports. The proposed system was tested in human urine and can detect S. aureus in human urine samples selectively, proving its potential in real-life applications. The reported approach is versatile enough for sensing other biomolecules and metal ions by choosing suitable receptors.
Collapse
Affiliation(s)
- Abdul Kaium Mia
- Centre for Nanotechnology, Indian Institute of Technology Guwahati, 781039, India.
| | - Abhilasha Bora
- Centre for Nanotechnology, Indian Institute of Technology Guwahati, 781039, India.
| | - Md Tarik Hossain
- Department of Physics, Indian Institute of Technology Guwahati, 781039, India
| | - Swapnil Sinha
- IITG TIDF BioNEST, Indian Institute of Technology Guwahati, 781039, India
| | - P K Giri
- Centre for Nanotechnology, Indian Institute of Technology Guwahati, 781039, India.
- Department of Physics, Indian Institute of Technology Guwahati, 781039, India
| |
Collapse
|
12
|
Li H, Yao S, Wang C, Bai C, Zhou P. Diverse applications and development of aptamer detection technology. ANAL SCI 2023; 39:1627-1641. [PMID: 37700097 DOI: 10.1007/s44211-023-00409-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Accepted: 06/04/2023] [Indexed: 09/14/2023]
Abstract
Aptamers have received extensive attention in recent years because of their advantages of high specificity, high sensitivity and low immunogenicity. Aptamers can perform almost all functions of antibodies through the combination of spatial structure and target, which are called "chemical antibodies". At present, aptamers have been widely used in cell imaging, new drug development, disease treatment, microbial detection and other fields. Due to the diversity of modifications, aptamers can be combined with different detection technologies to construct aptasensors. This review focuses on the diversity of aptamers in the field of detection and the development of aptamer-based detection technology and proposes new challenges for aptamers in this field.
Collapse
Affiliation(s)
- Haozheng Li
- College of Public Health, Hengyang Medical School, University of South China, Hengyang, 421001, Hunan, People's Republic of China
- Department of Radiation Biology, Beijing Key Laboratory for Radiobiology, Beijing Institute of Radiation Medicine, Beijing, 100850, People's Republic of China
| | - Shibo Yao
- Department of Radiation Biology, Beijing Key Laboratory for Radiobiology, Beijing Institute of Radiation Medicine, Beijing, 100850, People's Republic of China
| | - Cui Wang
- College of Public Health, Hengyang Medical School, University of South China, Hengyang, 421001, Hunan, People's Republic of China
- Department of Radiation Biology, Beijing Key Laboratory for Radiobiology, Beijing Institute of Radiation Medicine, Beijing, 100850, People's Republic of China
| | - Chenjun Bai
- Department of Radiation Biology, Beijing Key Laboratory for Radiobiology, Beijing Institute of Radiation Medicine, Beijing, 100850, People's Republic of China.
| | - Pingkun Zhou
- College of Public Health, Hengyang Medical School, University of South China, Hengyang, 421001, Hunan, People's Republic of China.
- Department of Radiation Biology, Beijing Key Laboratory for Radiobiology, Beijing Institute of Radiation Medicine, Beijing, 100850, People's Republic of China.
| |
Collapse
|
13
|
Kaushal S, Priyadarshi N, Garg P, Singhal NK, Lim DK. Nano-Biotechnology for Bacteria Identification and Potent Anti-bacterial Properties: A Review of Current State of the Art. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:2529. [PMID: 37764558 PMCID: PMC10536455 DOI: 10.3390/nano13182529] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 08/26/2023] [Accepted: 09/05/2023] [Indexed: 09/29/2023]
Abstract
Sepsis is a critical disease caused by the abrupt increase of bacteria in human blood, which subsequently causes a cytokine storm. Early identification of bacteria is critical to treating a patient with proper antibiotics to avoid sepsis. However, conventional culture-based identification takes a long time. Polymerase chain reaction (PCR) is not so successful because of the complexity and similarity in the genome sequence of some bacterial species, making it difficult to design primers and thus less suitable for rapid bacterial identification. To address these issues, several new technologies have been developed. Recent advances in nanotechnology have shown great potential for fast and accurate bacterial identification. The most promising strategy in nanotechnology involves the use of nanoparticles, which has led to the advancement of highly specific and sensitive biosensors capable of detecting and identifying bacteria even at low concentrations in very little time. The primary drawback of conventional antibiotics is the potential for antimicrobial resistance, which can lead to the development of superbacteria, making them difficult to treat. The incorporation of diverse nanomaterials and designs of nanomaterials has been utilized to kill bacteria efficiently. Nanomaterials with distinct physicochemical properties, such as optical and magnetic properties, including plasmonic and magnetic nanoparticles, have been extensively studied for their potential to efficiently kill bacteria. In this review, we are emphasizing the recent advances in nano-biotechnologies for bacterial identification and anti-bacterial properties. The basic principles of new technologies, as well as their future challenges, have been discussed.
Collapse
Affiliation(s)
- Shimayali Kaushal
- KU-KIST Graduate School of Converging Science and Technology, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea;
| | - Nitesh Priyadarshi
- National Agri-Food Biotechnology Institute (NABI), Sector-81, Mohali 140306, India; (N.P.); (P.G.)
| | - Priyanka Garg
- National Agri-Food Biotechnology Institute (NABI), Sector-81, Mohali 140306, India; (N.P.); (P.G.)
| | - Nitin Kumar Singhal
- National Agri-Food Biotechnology Institute (NABI), Sector-81, Mohali 140306, India; (N.P.); (P.G.)
| | - Dong-Kwon Lim
- KU-KIST Graduate School of Converging Science and Technology, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea;
- Department of Integrative Energy Engineering, College of Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
- Brain Science Institute, Korea Institute of Science and Technology (KIST), 5, Hwarang-ro 14-gil, Seongbuk-gu, Seoul 02792, Republic of Korea
| |
Collapse
|
14
|
Xu X, Lin X, Wang L, Ma Y, Sun T, Bian X. A Novel Dual Bacteria-Imprinted Polymer Sensor for Highly Selective and Rapid Detection of Pathogenic Bacteria. BIOSENSORS 2023; 13:868. [PMID: 37754102 PMCID: PMC10526176 DOI: 10.3390/bios13090868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 08/28/2023] [Accepted: 09/01/2023] [Indexed: 09/28/2023]
Abstract
The rapid, sensitive, and selective detection of pathogenic bacteria is of utmost importance in ensuring food safety and preventing the spread of infectious diseases. Here, we present a novel, reusable, and cost-effective impedimetric sensor based on a dual bacteria-imprinted polymer (DBIP) for the specific detection of Escherichia coli O157:H7 and Staphylococcus aureus. The DBIP sensor stands out with its remarkably short fabrication time of just 20 min, achieved through the efficient electro-polymerization of o-phenylenediamine monomer in the presence of dual bacterial templates, followed by in-situ template removal. The key structural feature of the DBIP sensor lies in the cavity-free imprinting sites, indicative of a thin layer of bacterial surface imprinting. This facilitates rapid rebinding of the target bacteria within a mere 15 min, while the sensing interface regenerates in just 10 min, enhancing the sensor's overall efficiency. A notable advantage of the DBIP sensor is its exceptional selectivity, capable of distinguishing the target bacteria from closely related bacterial strains, including different serotypes. Moreover, the sensor exhibits high sensitivity, showcasing a low detection limit of approximately 9 CFU mL-1. The sensor's reusability further enhances its cost-effectiveness, reducing the need for frequent sensor replacements. The practicality of the DBIP sensor was demonstrated in the analysis of real apple juice samples, yielding good recoveries. The integration of quick fabrication, high selectivity, rapid response, sensitivity, and reusability makes the DBIP sensor a promising solution for monitoring pathogenic bacteria, playing a crucial role in ensuring food safety and safeguarding public health.
Collapse
Affiliation(s)
- Xiaoli Xu
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
| | - Xiaohui Lin
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
| | - Lingling Wang
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
| | - Yixin Ma
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
| | - Tao Sun
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
| | - Xiaojun Bian
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
- Laboratory of Quality and Safety Risk Assessment for Aquatic Product on Storage and Preservation (Shanghai), Ministry of Agriculture, Shanghai 201306, China
- Shanghai Engineering Research Center of Aquatic-Product Processing & Preservation, Shanghai 201306, China
| |
Collapse
|
15
|
Yan M, Wang H, Li M, Zhang W, Du H, Chen Z, Zhu C, She Y. Multicolor aptasensors for pesticide multiresidues detection in agricultural products using bioorthogonal surface-enhanced Raman scattering tags. Talanta 2023; 265:124800. [PMID: 37392707 DOI: 10.1016/j.talanta.2023.124800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 05/31/2023] [Accepted: 06/09/2023] [Indexed: 07/03/2023]
Abstract
Realizing accurate pesticide multiresidue detection in a complex matrix is still a challenge for point-of-care sensing methods. Herein, we introduced background-free and multicolor aptasensors based on bioorthogonal surface-enhanced Raman scattering (SERS) tags and successfully applied them to analyze multiple pesticide residues. The excellent anti-interference and multiplex capability are due to the application of three bioorthogonal Raman reporters involving 4-ethenylbenzenamine (4-EBZM), Prussian blue (PB) and 2-amino-4-cyanopyridine (AMCP) with alkynyl and cyano groups, which demonstrated apparent Raman shift peaks at 1993 cm-1, 2160 cm-1, and 2264 cm-1 in the biologically Raman-silent region, respectively. Ultimately, a detection range of 1-50 nM for acetamiprid, atrazine and malathion was achieved with detection limits of 0.39, 0.57 and 0.16 nM, respectively. The developed aptasensors were successfully used to determine pesticide residues in real samples. These proposed multicolor aptasensors offer an effective strategy for pesticide multiresidue detection with advantages of anti-interference, high specificity and high sensitivity.
Collapse
Affiliation(s)
- Mengmeng Yan
- Institute of Quality Standard and Testing Technology for Agro-Products, Shandong Academy of Agricultural Sciences, Jinan, 250100, China; Shandong Provincial Key Laboratory Test Technology on Food Quality and Safety, Jinan, 250100, China
| | - Hao Wang
- Institute of Quality Standard and Testing Technology for Agro-Products, Shandong Academy of Agricultural Sciences, Jinan, 250100, China; Shandong Provincial Key Laboratory Test Technology on Food Quality and Safety, Jinan, 250100, China
| | - Min Li
- Institute of Quality Standard and Testing Technology for Agro-Products, Shandong Academy of Agricultural Sciences, Jinan, 250100, China; Shandong Provincial Key Laboratory Test Technology on Food Quality and Safety, Jinan, 250100, China
| | - Wenjun Zhang
- Institute of Quality Standard and Testing Technology for Agro-Products, Shandong Academy of Agricultural Sciences, Jinan, 250100, China; Shandong Provincial Key Laboratory Test Technology on Food Quality and Safety, Jinan, 250100, China
| | - Hongxia Du
- Institute of Quality Standard and Testing Technology for Agro-Products, Shandong Academy of Agricultural Sciences, Jinan, 250100, China; Shandong Provincial Key Laboratory Test Technology on Food Quality and Safety, Jinan, 250100, China
| | - Zilei Chen
- Institute of Quality Standard and Testing Technology for Agro-Products, Shandong Academy of Agricultural Sciences, Jinan, 250100, China; Shandong Provincial Key Laboratory Test Technology on Food Quality and Safety, Jinan, 250100, China
| | - Chao Zhu
- Institute of Quality Standard and Testing Technology for Agro-Products, Shandong Academy of Agricultural Sciences, Jinan, 250100, China; Shandong Provincial Key Laboratory Test Technology on Food Quality and Safety, Jinan, 250100, China.
| | - Yongxin She
- Institute of Quality Standard and Testing Technology for Agro-Products, Chinese Academy of Agricultural Science, Beijing 100081, China.
| |
Collapse
|
16
|
Spagnolo S, Davoudian K, De La Franier B, Hianik T, Thompson M. Staphylococcus aureus Detection in Milk Using a Thickness Shear Mode Acoustic Aptasensor with an Antifouling Probe Linker. BIOSENSORS 2023; 13:614. [PMID: 37366979 DOI: 10.3390/bios13060614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 05/25/2023] [Accepted: 06/01/2023] [Indexed: 06/28/2023]
Abstract
Contamination of food by pathogens can pose a serious risk to health. Therefore, monitoring for the presence of pathogens is critical to identify and regulate microbiological contamination of food. In this work, an aptasensor based on a thickness shear mode acoustic method (TSM) with dissipation monitoring was developed to detect and quantify Staphylococcus aureus directly in whole UHT cow's milk. The frequency variation and dissipation data demonstrated the correct immobilization of the components. The analysis of viscoelastic properties suggests that DNA aptamers bind to the surface in a non-dense manner, which favors the binding with bacteria. The aptasensor demonstrated high sensitivity and was able to detect S. aureus in milk with a 33 CFU/mL limit of detection. Analysis was successful in milk due to the sensor's antifouling properties, which is based on 3-dithiothreitol propanoic acid (DTTCOOH) antifouling thiol linker. Compared to bare and modified (dithiothreitol (DTT), 11-mercaptoundecanoic acid (MUA), and 1-undecanethiol (UDT)) quartz crystals, the sensitivity of the sensor's antifouling in milk improved by about 82-96%. The excellent sensitivity and ability to detect and quantify S. aureus in whole UHT cow's milk demonstrates that the system is applicable for rapid and efficient analysis of milk safety.
Collapse
Affiliation(s)
- Sandro Spagnolo
- Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynská Dolina F1, 84248 Bratislava, Slovakia
| | - Katharina Davoudian
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S3H6, Canada
| | - Brian De La Franier
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S3H6, Canada
| | - Tibor Hianik
- Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynská Dolina F1, 84248 Bratislava, Slovakia
| | - Michael Thompson
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S3H6, Canada
| |
Collapse
|
17
|
Boodoo C, Dester E, David J, Patel V, Kc R, Alocilja EC. Multi-Probe Nano-Genomic Biosensor to Detect S. aureus from Magnetically-Extracted Food Samples. BIOSENSORS 2023; 13:608. [PMID: 37366975 DOI: 10.3390/bios13060608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Revised: 04/18/2023] [Accepted: 05/10/2023] [Indexed: 06/28/2023]
Abstract
One of the most prevalent causes of foodborne illnesses worldwide is staphylococcal food poisoning. This study aimed to provide a robust method to extract the bacteria Staphylococcus aureus from food samples using glycan-coated magnetic nanoparticles (MNPs). Then, a cost-effective multi-probe genomic biosensor was designed to detect the nuc gene of S. aureus rapidly in different food matrices. This biosensor utilized gold nanoparticles and two DNA oligonucleotide probes combined to produce a plasmonic/colorimetric response to inform users if the sample was positive for S. aureus. In addition, the specificity and sensitivity of the biosensor were determined. For the specificity trials, the S. aureus biosensor was compared with the extracted DNA of Escherichia coli, Salmonella enterica serovar Enteritidis (SE), and Bacillus cereus. The sensitivity tests showed that the biosensor could detect as low as 2.5 ng/µL of the target DNA with a linear range of up to 20 ng/µL of DNA. With further research, this simple and cost-effective biosensor can rapidly identify foodborne pathogens from large-volume samples.
Collapse
Affiliation(s)
- Chelsie Boodoo
- Nano-Biosensors Lab, Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI 48824, USA
- Global Alliance for Rapid Diagnostics, Michigan State University, East Lansing, MI 48824, USA
| | - Emma Dester
- Nano-Biosensors Lab, Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI 48824, USA
- Global Alliance for Rapid Diagnostics, Michigan State University, East Lansing, MI 48824, USA
| | - Jeswin David
- Nano-Biosensors Lab, Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI 48824, USA
- Department of Human Biology, Michigan State University, East Lansing, MI 48824, USA
| | - Vedi Patel
- Nano-Biosensors Lab, Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI 48824, USA
- Department of Mechanical Engineering, Michigan State University, East Lansing, MI 48824, USA
| | - Rabin Kc
- Statistical Consulting Center, College of Agriculture and Natural Resources, Michigan State University, East Lansing, MI 48824, USA
| | - Evangelyn C Alocilja
- Nano-Biosensors Lab, Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI 48824, USA
- Global Alliance for Rapid Diagnostics, Michigan State University, East Lansing, MI 48824, USA
| |
Collapse
|
18
|
Mi F, Guan M, Wang Y, Chen G, Geng P. A SERS biosensor based on aptamer-based Fe3O4@SiO2@Ag magnetic recognition and embedded SERS probes for ultrasensitive simultaneous detection of Staphylococcus aureus and Escherichia coli. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2023]
|
19
|
He H, Sun DW, Pu H, Wu Z. A SERS-Fluorescence dual-signal aptasensor for sensitive and robust determination of AFB1 in nut samples based on Apt-Cy5 and MNP@Ag-PEI. Talanta 2023; 253:123962. [PMID: 36208559 DOI: 10.1016/j.talanta.2022.123962] [Citation(s) in RCA: 32] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 09/18/2022] [Accepted: 09/20/2022] [Indexed: 12/13/2022]
Abstract
Food aflatoxin B1 (AFB1) contamination greatly threatens human health and its sensitive determination is imperative. In this study, a surface-enhanced Raman scattering (SERS) and fluorescence dual-signal aptasensor was constructed for sensitive AFB1 detection in peanuts, walnuts, and almonds samples. Fluorescent dye cy5 was used as fluorophore and Raman reporter, while polyethyleneimine modified Ag coating magnetic nanoparticles (MNP@Ag-PEI) were utilized to absorb the cy5 modified aptamer (apt-cy5). Results indicated that linear ranges of 0.001-1000 ng/mL and 0.2-20,000 ng/mL with detection limits of 0.45 pg/mL and 0.135 ng/mL for the SERS and fluorescence methods were obtained, respectively, and AFB1 detection in the nut samples using the aptasensor achieved satisfactory recoveries of 95.2%-108.6% for SERS and 94.7%-109.7% for fluorescence. Compared with other mono signal detection, the established aptasensor facilely fused the merits of the two signals and improved the detection accuracy and flexibility.
Collapse
Affiliation(s)
- Haoyang He
- School of Food Science and Engineering, South China University of Technology, Guangzhou, 510641, China; Academy of Contemporary Food Engineering, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, China; Engineering and Technological Research Centre of Guangdong Province on Intelligent Sensing and Process Control of Cold Chain Foods, & Guangdong Province Engineering Laboratory for Intelligent Cold Chain Logistics Equipment for Agricultural Products, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, China
| | - Da-Wen Sun
- School of Food Science and Engineering, South China University of Technology, Guangzhou, 510641, China; Academy of Contemporary Food Engineering, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, China; Engineering and Technological Research Centre of Guangdong Province on Intelligent Sensing and Process Control of Cold Chain Foods, & Guangdong Province Engineering Laboratory for Intelligent Cold Chain Logistics Equipment for Agricultural Products, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, China; Food Refrigeration and Computerized Food Technology (FRCFT), Agriculture and Food Science Centre, University College Dublin, National University of Ireland, Belfield, Dublin 4, Ireland.
| | - Hongbin Pu
- School of Food Science and Engineering, South China University of Technology, Guangzhou, 510641, China; Academy of Contemporary Food Engineering, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, China; Engineering and Technological Research Centre of Guangdong Province on Intelligent Sensing and Process Control of Cold Chain Foods, & Guangdong Province Engineering Laboratory for Intelligent Cold Chain Logistics Equipment for Agricultural Products, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, China
| | - Zhihui Wu
- School of Food Science and Engineering, South China University of Technology, Guangzhou, 510641, China; Academy of Contemporary Food Engineering, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, China; Engineering and Technological Research Centre of Guangdong Province on Intelligent Sensing and Process Control of Cold Chain Foods, & Guangdong Province Engineering Laboratory for Intelligent Cold Chain Logistics Equipment for Agricultural Products, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, China
| |
Collapse
|
20
|
Liu Z, Wang C, Zheng S, Yang X, Han H, Dai Y, Xiao R. Simultaneously ultrasensitive and quantitative detection of influenza A virus, SARS-CoV-2, and respiratory syncytial virus via multichannel magnetic SERS-based lateral flow immunoassay. NANOMEDICINE : NANOTECHNOLOGY, BIOLOGY, AND MEDICINE 2023; 47:102624. [PMID: 36328340 PMCID: PMC9622431 DOI: 10.1016/j.nano.2022.102624] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 07/30/2022] [Accepted: 10/24/2022] [Indexed: 11/06/2022]
Abstract
Respiratory viruses usually induced similar clinical symptoms at early infection. Herein, we presented a multichannel surface-enhanced Raman scattering-based lateral flow immunoassay (SERS-based LFA) using high-performance magnetic SERS tags for the simultaneous ultrasensitive detection of respiratory viruses, namely influenza A virus (H1N1), severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and respiratory syncytial virus (RSV) in biological samples. As-prepared magnetic SERS tags can directly enrich and capture target viruses without pretreatment of samples, avoiding the interference of impurities in the samples as well as improving the sensitivity. With the capture-detection method, the detection limits of the proposed assay reached 85 copies mL-1, 8 pg mL-1, and 8 pg mL-1 for H1N1, SARS-CoV-2 and RSV, respectively. Moreover, the detection properties of the proposed method for target viruses in throat swab samples were verified, suggesting its remarkable potential for the early and rapid differential diagnosis of respiratory viruses.
Collapse
|
21
|
Huang H, Zhang Z, Li G. A Review of Magnetic Nanoparticle-Based Surface-Enhanced Raman Scattering Substrates for Bioanalysis: Morphology, Function and Detection Application. BIOSENSORS 2022; 13:30. [PMID: 36671865 PMCID: PMC9855913 DOI: 10.3390/bios13010030] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 12/15/2022] [Accepted: 12/24/2022] [Indexed: 06/17/2023]
Abstract
Surface-enhanced Raman scattering (SERS) is a kind of popular non-destructive and water-free interference analytical technology with fast response, excellent sensitivity and specificity to trace biotargets in biological samples. Recently, many researches have focused on the preparation of various magnetic nanoparticle-based SERS substrates for developing efficient bioanalytical methods, which greatly improved the selectivity and accuracy of the proposed SERS bioassays. There has been a rapid increase in the number of reports about magnetic SERS substrates in the past decade, and the number of related papers and citations have exceeded 500 and 2000, respectively. Moreover, most of the papers published since 2009 have been dedicated to analytical applications. In the paper, the recent advances in magnetic nanoparticle-based SERS substrates for bioanalysis were reviewed in detail based on their various morphologies, such as magnetic core-shell nanoparticles, magnetic core-satellite nanoparticles and non-spherical magnetic nanoparticles and their different functions, such as separation and enrichment, recognition and SERS tags. Moreover, the typical application progress on magnetic nanoparticle-based SERS substrates for bioanalysis of amino acids and protein, DNA and RNA sequences, cancer cells and related tumor biomarkers, etc., was summarized and introduced. Finally, the future trends and prospective for SERS bioanalysis by magnetic nanoparticle-based substrates were proposed based on the systematical study of typical and latest references. It is expected that this review would provide useful information and clues for the researchers with interest in SERS bioanalysis.
Collapse
Affiliation(s)
| | - Zhuomin Zhang
- School of Chemistry, Sun Yat-sen University, Guangzhou 510006, China
| | - Gongke Li
- School of Chemistry, Sun Yat-sen University, Guangzhou 510006, China
| |
Collapse
|
22
|
Dayalan S, Gedda G, Li R, Zulfajri M, Huang GG. Vancomycin functionalization of gold nanostars for sensitive detection of foodborne pathogens through surface‐enhanced Raman scattering. J CHIN CHEM SOC-TAIP 2022. [DOI: 10.1002/jccs.202200421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Sandhiya Dayalan
- Department of Medicinal and Applied Chemistry Kaohsiung Medical University Kaohsiung Taiwan
| | - Gangaraju Gedda
- Department of Chemistry, School of Engineering Presidency University Bangalore India
| | - Ruei–Nian Li
- Department of Biomedical Science and Environmental Biology Kaohsiung Medical University Kaohsiung Taiwan
| | - Muhammad Zulfajri
- Department of Chemistry Education Universitas Serambi Mekkah Banda Aceh Indonesia
| | - Genin Gary Huang
- Department of Medicinal and Applied Chemistry Kaohsiung Medical University Kaohsiung Taiwan
- Department of Medical Research Kaohsiung Medical University Hospital Kaohsiung Taiwan
- Department of Chemistry National Sun Yat‐sen University Kaohsiung Taiwan
| |
Collapse
|
23
|
Fluorophore-Tagged Poly(ʟ-Lysine) Block copolymer Nano-assemblies for Real-time Visualization and Antimicrobial Activity. Eur Polym J 2022. [DOI: 10.1016/j.eurpolymj.2022.111754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
24
|
Kim JK, Yun H, Yeom CH, Kim EJ, Kim W, Lee CS, Kim BG, Jeong HJ. Flow cytometry-based rapid detection of Staphylococcus aureus and Pseudomonas aeruginosa using fluorescent antibodies. RSC Adv 2022; 12:34660-34669. [PMID: 36545616 PMCID: PMC9717348 DOI: 10.1039/d2ra05694a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Accepted: 11/26/2022] [Indexed: 12/04/2022] Open
Abstract
Staphylococcus aureus (S. aureus) and Pseudomonas aeruginosa (P. aeruginosa) are major pathogens frequently detected in food and beverage poisoning, and persistent infections. Therefore, the development of a rapid method that can detect these pathogens before serious multiplication is required. In this study, we established a flow cytometry (FCM)-based detection method that allows rapid acquisition of cell populations in fluid samples by using a fluorescent antibody against S. aureus or P. aeruginosa. Using this method, we detected these pathogens with a 103 to 105 CFU order of limit of detection value within 1 hour. The FCM-based method for the detection of S. aureus and P. aeruginosa offers the possibility of high-throughput analysis of pathogens in food, environmental, and clinical sources.
Collapse
Affiliation(s)
- Joo-Kyung Kim
- Interdisciplinary Program for Biochemical Engineering and Biotechnology, Seoul National UniversitySeoul08826South Korea
| | - Hanool Yun
- Department of Biological and Chemical Engineering, Hongik UniversitySejong30016South Korea
| | - Chang-Hun Yeom
- Department of Biological and Chemical Engineering, Hongik UniversitySejong30016South Korea
| | - Eun-Jung Kim
- Bio-MAX/N-Bio, Seoul National UniversitySeoul08826South Korea
| | - Wooseong Kim
- College of Pharmacy and Graduate School of Pharmaceutical Sciences, Ewha Womans UniversitySeoul 03760South Korea
| | - Chang-Soo Lee
- Department of Chemical Engineering and Applied Chemistry, Chungnam National UniversityDaejeon 34134South Korea
| | - Byung-Gee Kim
- Interdisciplinary Program for Biochemical Engineering and Biotechnology, Seoul National UniversitySeoul08826South Korea,Bio-MAX/N-Bio, Seoul National UniversitySeoul08826South Korea
| | - Hee-Jin Jeong
- Department of Biological and Chemical Engineering, Hongik UniversitySejong30016South Korea
| |
Collapse
|
25
|
Liu X, Du X, Huang Y, Pang B, Zhang M, Ma Y, Wang X, Song X, Li J, Li J. Rapid detection of four pathogens in bloodstream infection by antimicrobial peptide capture combined with multiplex PCR and capillary electrophoresis. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
26
|
Rapid detection of Staphylococcus aureus in food safety using an RPA-CRISPR-Cas12a assay. Food Control 2022. [DOI: 10.1016/j.foodcont.2022.109505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
27
|
de la Encarnación C, Jimenez de Aberasturi D, Liz-Marzán LM. Multifunctional plasmonic-magnetic nanoparticles for bioimaging and hyperthermia. Adv Drug Deliv Rev 2022; 189:114484. [PMID: 35944586 DOI: 10.1016/j.addr.2022.114484] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 06/28/2022] [Accepted: 08/03/2022] [Indexed: 01/24/2023]
Abstract
Multicompartment nanoparticles have raised great interest for different biomedical applications, thanks to the combined properties of different materials within a single entity. These hybrid systems have opened new avenues toward diagnosis and combination therapies, thus becoming preferred theranostic agents. When hybrid nanoparticles comprise magnetic and plasmonic components, both magnetic and optical properties can be achieved, which are potentially useful for multimodal bioimaging, hyperthermal therapies and magnetically driven selective delivery. Nanostructures comprising iron oxide and gold are usually selected for biomedical applications, as they display size-dependent properties, biocompatibility, and unique physical and chemical characteristics that can be tuned through highly precise synthetic protocols. We provide herein an overview of the most recent synthetic protocols to prepare magnetic-plasmonic nanostructures made of iron oxide and gold, to then highlight the progress made on multifunctional magnetic-plasmonic bioimaging and heating-based therapies. We discuss the advantages and limitations of the various systems in these directions.
Collapse
Affiliation(s)
- Cristina de la Encarnación
- CIC biomaGUNE, Basque Research and Technology Alliance (BRTA), Paseo de Miramón 194, 20014 Donostia-San Sebastián, Spain; Department of Applied Chemistry, University of the Basque Country, 20018 Donostia-San Sebastián, Spain
| | - Dorleta Jimenez de Aberasturi
- CIC biomaGUNE, Basque Research and Technology Alliance (BRTA), Paseo de Miramón 194, 20014 Donostia-San Sebastián, Spain; CIBER-BBN, ISCIII, 20014 Donostia-San Sebastián, Spain; Ikerbasque, Basque Foundation for Science, 48009 Bilbao, Spain.
| | - Luis M Liz-Marzán
- CIC biomaGUNE, Basque Research and Technology Alliance (BRTA), Paseo de Miramón 194, 20014 Donostia-San Sebastián, Spain; CIBER-BBN, ISCIII, 20014 Donostia-San Sebastián, Spain; Ikerbasque, Basque Foundation for Science, 48009 Bilbao, Spain.
| |
Collapse
|
28
|
Wu T, Li J, Zheng S, Yu Q, Qi K, Shao Y, Wang C, Tu J, Xiao R. Magnetic Nanotag-Based Colorimetric/SERS Dual-Readout Immunochromatography for Ultrasensitive Detection of Clenbuterol Hydrochloride and Ractopamine in Food Samples. BIOSENSORS 2022; 12:bios12090709. [PMID: 36140094 PMCID: PMC9496078 DOI: 10.3390/bios12090709] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 08/28/2022] [Accepted: 08/28/2022] [Indexed: 12/29/2022]
Abstract
Direct and sensitive detection of multiple illegal additives in complex food samples is still a challenge in on-site detection. In this study, an ultrasensitive immunochromatographic assay (ICA) using magnetic Fe3O4@Au nanotags as a capture/detection difunctional tool was developed for the direct detection of β2-adrenoceptor agonists in real samples. The Fe3O4@Au tag is composed of a large magnetic core (~160 nm), a rough Au nanoshell, dense surface-modified Raman molecules, and antibodies, which cannot only effectively enrich targets from complex solutions to reduce the matrix effects of food samples and improve detection sensitivity, but also provide strong colorimetric/surface-enhanced Raman scattering (SERS) dual signals for ICA testing. The dual readout signals of the proposed ICA can meet the detection requirements in different environments. Specifically, the colorimetric signal allows for rapid visual detection of the analyte, and the SERS signal is used for the sensitive and quantitative detection modes. The proposed dual-signal ICA can achieve the simultaneous determination of two illegal additives, namely, clenbuterol hydrochloride and ractopamine. The detection limits for the two targets via colorimetric and SERS signals were down to ng mL−1 and pg mL−1 levels, respectively. Moreover, the proposed assay has demonstrated high accuracy and stability in real food samples.
Collapse
Affiliation(s)
- Ting Wu
- Anhui Province Key Laboratory of Veterinary Pathobiology and Disease Control, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, China
- Beijing Institute of Microbiology and Epidemiology, Beijing 100850, China
| | - Jiaxuan Li
- Anhui Province Key Laboratory of Veterinary Pathobiology and Disease Control, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, China
- Beijing Institute of Microbiology and Epidemiology, Beijing 100850, China
| | - Shuai Zheng
- College of Life Sciences, Anhui Agricultural University, Hefei 230036, China
| | - Qing Yu
- College of Life Sciences, Anhui Agricultural University, Hefei 230036, China
| | - Kezong Qi
- Anhui Province Key Laboratory of Veterinary Pathobiology and Disease Control, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, China
- College of Life Sciences, Anhui Agricultural University, Hefei 230036, China
| | - Ying Shao
- Anhui Province Key Laboratory of Veterinary Pathobiology and Disease Control, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, China
- College of Life Sciences, Anhui Agricultural University, Hefei 230036, China
| | - Chongwen Wang
- Anhui Province Key Laboratory of Veterinary Pathobiology and Disease Control, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, China
- Beijing Institute of Microbiology and Epidemiology, Beijing 100850, China
- College of Life Sciences, Anhui Agricultural University, Hefei 230036, China
- Correspondence: (C.W.); (J.T.); (R.X.)
| | - Jian Tu
- Anhui Province Key Laboratory of Veterinary Pathobiology and Disease Control, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, China
- Correspondence: (C.W.); (J.T.); (R.X.)
| | - Rui Xiao
- Beijing Institute of Microbiology and Epidemiology, Beijing 100850, China
- Correspondence: (C.W.); (J.T.); (R.X.)
| |
Collapse
|
29
|
Jiang G, Li Y, Liu J, Liu L, Pi F. Progress on aptamer-based SERS sensors for food safety and quality assessment: methodology, current applications and future trends. Crit Rev Food Sci Nutr 2022; 64:783-800. [PMID: 35943403 DOI: 10.1080/10408398.2022.2108370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
It is well known that food safety has aroused extensive attentions from governments to researchers and to food industries. As a versatile technology based on molecular interactions, aptamer sensors which could specifically identify a wide range of food contaminants have been extensively studied in recent years. Surface-enhanced Raman spectroscopy integrated aptamer combines the advantages of both technologies, not only in the ability to specifically identify a wide range of food contaminants, but also in the ultra-high sensitivity, simplicity, portable and speed. To provide beneficial insights into the evaluation techniques in the field of food safety, we offer a comprehensive review on the design strategies for aptamer-SERS sensors in different scenarios, including non-nucleic acid amplification methods ("on/off" mode, sandwich mode, competition model and catalytic model) and nucleic acid amplification methods (hybridization chain reaction, rolling circle amplification, catalytic hairpin assembly). Meanwhile, a special attention is paid to the application of aptamer-SERS sensors in biological (foodborne pathogenic, bacteria and mycotoxins) and chemical contamination (drug residues, metal ions, and food additives) of food matrix. Finally, the challenges and prospects of developing reliable aptamer-SERS sensors for food safety were discussed, which are expected to offer a strong guidance for further development and extended applications.
Collapse
Affiliation(s)
- Guoyong Jiang
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu, People's Republic of China
- Collaborative Innovation Center of Food Safety and Quality Control in Jiangsu Province, Jiangnan University, Wuxi, Jiangsu, People's Republic of China
| | - Yu Li
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu, People's Republic of China
- Collaborative Innovation Center of Food Safety and Quality Control in Jiangsu Province, Jiangnan University, Wuxi, Jiangsu, People's Republic of China
| | - Jinghan Liu
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu, People's Republic of China
- Collaborative Innovation Center of Food Safety and Quality Control in Jiangsu Province, Jiangnan University, Wuxi, Jiangsu, People's Republic of China
| | - Ling Liu
- Wuxi Institute of Technology, Wuxi, Jiangsu, People's Republic of China
| | - Fuwei Pi
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu, People's Republic of China
- Collaborative Innovation Center of Food Safety and Quality Control in Jiangsu Province, Jiangnan University, Wuxi, Jiangsu, People's Republic of China
| |
Collapse
|
30
|
Pebdeni AB, Hosseini M, Barkhordari A. Smart fluorescence aptasensor using nanofiber functionalized with carbon quantum dot for specific detection of pathogenic bacteria in the wound. Talanta 2022; 246:123454. [DOI: 10.1016/j.talanta.2022.123454] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 03/31/2022] [Accepted: 04/03/2022] [Indexed: 01/23/2023]
|
31
|
Banu K, Mondal B, Rai B, Monica N, Hanumegowda R. Prospects for the application of aptamer based assay platforms in pathogen detection. Biocybern Biomed Eng 2022. [DOI: 10.1016/j.bbe.2022.07.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
32
|
Chen W, Lai Q, Zhang Y, Liu Z. Recent Advances in Aptasensors For Rapid and Sensitive Detection of Staphylococcus Aureus. Front Bioeng Biotechnol 2022; 10:889431. [PMID: 35677308 PMCID: PMC9169243 DOI: 10.3389/fbioe.2022.889431] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Accepted: 04/12/2022] [Indexed: 12/30/2022] Open
Abstract
The infection of Staphylococcus aureus (S.aureus) and the spread of drug-resistant bacteria pose a serious threat to global public health. Therefore, timely, rapid and accurate detection of S. aureus is of great significance for food safety, environmental monitoring, clinical diagnosis and treatment, and prevention of drug-resistant bacteria dissemination. Traditional S. aureus detection methods such as culture identification, ELISA, PCR, MALDI-TOF-MS and sequencing, etc., have good sensitivity and specificity, but they are complex to operate, requiring professionals and expensive and complex machines. Therefore, it is still challenging to develop a fast, simple, low-cost, specific and sensitive S. aureus detection method. Recent studies have demonstrated that fast, specific, low-cost, low sample volume, automated, and portable aptasensors have been widely used for S. aureus detection and have been proposed as the most attractive alternatives to their traditional detection methods. In this review, recent advances of aptasensors based on different transducer (optical and electrochemical) for S. aureus detection have been discussed in details. Furthermore, the applications of aptasensors in point-of-care testing (POCT) have also been discussed. More and more aptasensors are combined with nanomaterials as efficient transducers and amplifiers, which appears to be the development trend in aptasensors. Finally, some significant challenges for the development and application of aptasensors are outlined.
Collapse
Affiliation(s)
- Wei Chen
- Department of Clinical Laboratory, Xiangya Hospital of Central South University, Changsha, China
- National Clinical Research Center for Geriatric Diseases, Xiangya Hospital of Central South University, Changsha, China
- Hunan Key Laboratory for Super Microstructure and Ultrafast Process, School of Physics and Electronics, Central South University, Changsha, China
- Department of Microbiology, School of Basic Medical Science, Central South University, Changsha, China
- *Correspondence: Wei Chen, ; Zhengchun Liu,
| | - Qingteng Lai
- Hunan Key Laboratory for Super Microstructure and Ultrafast Process, School of Physics and Electronics, Central South University, Changsha, China
| | - Yanke Zhang
- Hunan Key Laboratory for Super Microstructure and Ultrafast Process, School of Physics and Electronics, Central South University, Changsha, China
| | - Zhengchun Liu
- Hunan Key Laboratory for Super Microstructure and Ultrafast Process, School of Physics and Electronics, Central South University, Changsha, China
- Department of Microbiology, School of Basic Medical Science, Central South University, Changsha, China
- *Correspondence: Wei Chen, ; Zhengchun Liu,
| |
Collapse
|
33
|
Ommen P, Hansen L, Hansen BK, Vu-Quang H, Kjems J, Meyer RL. Aptamer-Targeted Drug Delivery for Staphylococcus aureus Biofilm. Front Cell Infect Microbiol 2022; 12:814340. [PMID: 35573794 PMCID: PMC9104115 DOI: 10.3389/fcimb.2022.814340] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Accepted: 02/09/2022] [Indexed: 12/12/2022] Open
Abstract
Treatment of Staphylococcus aureus biofilm infections using conventional antibiotic therapy is challenging as only doses that are sublethal to the biofilm can be administered safely to patients. A potential solution to this challenge is targeted drug delivery. In this study, we tailored an aptamer-targeted liposomal drug delivery system for accumulation and delivery of antibiotics locally in S. aureus biofilm. In our search for a suitable targeting ligand, we identified six DNA aptamers that bound to S. aureus cells in biofilms, and we demonstrated that one of these aptamers could facilitate accumulation of liposomes around S. aureus cells inside the biofilm. Aptamer-targeted liposomes encapsulating a combination of vancomycin and rifampicin were able to eradicate S. aureus biofilm upon 24 h of treatment in vitro. Our results point to that aptamer-targeted drug delivery of antibiotics is a potential new strategy for treatment of S. aureus biofilm infections.
Collapse
Affiliation(s)
- Pernille Ommen
- Interdisciplinary Nanoscience Center, Aarhus University, Aarhus C, Denmark
| | - Line Hansen
- Interdisciplinary Nanoscience Center, Aarhus University, Aarhus C, Denmark
| | - Bente K. Hansen
- Interdisciplinary Nanoscience Center, Aarhus University, Aarhus C, Denmark
| | - Hieu Vu-Quang
- Interdisciplinary Nanoscience Center, Aarhus University, Aarhus C, Denmark
| | - Jørgen Kjems
- Interdisciplinary Nanoscience Center, Aarhus University, Aarhus C, Denmark
- Department of Bioscience, Aarhus University, Aarhus C, Denmark
| | - Rikke L. Meyer
- Interdisciplinary Nanoscience Center, Aarhus University, Aarhus C, Denmark
- Department of Bioscience, Aarhus University, Aarhus C, Denmark
| |
Collapse
|
34
|
Zhou X, Li P, Wu X, Lin X, Zhao L, Huang H, Wu J, Cai H, Xu M, Zhou H, Sun P. Multifunctional biosensor constructed by Ag-coating magnetic-assisted unique urchin core porous shell structure for dual SERS enhancement, enrichment, and quantitative detection of multi-components inflammatory markers. Biosens Bioelectron 2022; 210:114257. [PMID: 35447395 DOI: 10.1016/j.bios.2022.114257] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Revised: 04/03/2022] [Accepted: 04/05/2022] [Indexed: 01/14/2023]
Abstract
The simultaneous, precise, and quantitative detection of multi-components inflammatory markers (IMs) in sepsis serum by surface-enhanced Raman scattering (SERS) remains a challenging problem. A novel, multifunctional biosensor with dual enrichment and enhancement was designed for the ultrasensitive and quantitative analysis of multi-components IMs. The biosensor contains SERS tags-unique urchin core/porous shell (CPS) structure modified with Raman reporters (RaRs), magnetic assist-Ag coated Fe3O4 magnetic nanoparticles (Ag MNPs) modified with internal standard (IS), and then aptamer (Apt) modification to form the sandwich structure (Ag MNPs/IMs/CPS). This multifunctional sensor used for IMS detection has the following innovations: The intensity ratio IRaRs/IIS with Lg CIMs present a good and wide linear relationship to achieve the simultaneous, precise, and quantitative detection of IMS in serum; The detection results display ultrasensitivity, and the limit of detection (LOD) for CRP, IL-6, and PCT is 100 fg/mL, 0.1 fg/mL, and 1.0 fg/mL, which is lower than other detection techniques; The calculated data of clinical blood samples of sepsis by this SERS method is consistent with the hospital results, and can provide more compositional data of IMs. Thus, this combined approach developed a sensing platform for rapid screening, accurate evaluation, early warning, and diagnosis of sepsis.
Collapse
Affiliation(s)
- Xia Zhou
- Department of Oncology, The First Affiliated Hospital of Jinan University, Guangzhou, Guangdong, 510632, China; College of Pharmacy, Jinan University, Guangzhou, Guangdong, 510632, China
| | - Ping Li
- College of Pharmacy, Jinan University, Guangzhou, Guangdong, 510632, China
| | - Xueqiang Wu
- Center for Precision Medicine, Meizhou People's Hospital, Meizhou, Guangdong, 514031, China
| | - Xiaoling Lin
- College of Pharmacy, Jinan University, Guangzhou, Guangdong, 510632, China
| | - Li Zhao
- College of Pharmacy, Jinan University, Guangzhou, Guangdong, 510632, China
| | - Haiqiu Huang
- College of Pharmacy, Jinan University, Guangzhou, Guangdong, 510632, China
| | - Jiamin Wu
- College of Pharmacy, Jinan University, Guangzhou, Guangdong, 510632, China
| | - Huaihong Cai
- Department of Chemistry, College of Chemistry and Materials Science, Jinan University, Guangzhou, Guangdong, 510632, China
| | - Meng Xu
- Department of Oncology, The First Affiliated Hospital of Jinan University, Guangzhou, Guangdong, 510632, China.
| | - Haibo Zhou
- Department of Oncology, The First Affiliated Hospital of Jinan University, Guangzhou, Guangdong, 510632, China; College of Pharmacy, Jinan University, Guangzhou, Guangdong, 510632, China.
| | - Pinghua Sun
- Department of Oncology, The First Affiliated Hospital of Jinan University, Guangzhou, Guangdong, 510632, China; College of Pharmacy, Jinan University, Guangzhou, Guangdong, 510632, China.
| |
Collapse
|
35
|
Yan M, Li H, Li M, Cao X, She Y, Chen Z. Advances in Surface-Enhanced Raman Scattering-Based Aptasensors for Food Safety Detection. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2021; 69:14049-14064. [PMID: 34798776 DOI: 10.1021/acs.jafc.1c05274] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Owing to the excellent performances of high sensitivity, high specificity, on-site detection, and multiplexing capability, surface-enhanced Raman scattering (SERS)-based aptasensors have performed prosperous applications and gained impressive progress in food safety. Herein, we reviewed the SERS-based aptasensors from the principles to specific applications in food safety. First, the sensor-working principles, SERS label design and preparation are introduced. Then, the popular platforms in the aptasensors are summarized with their advantages and disadvantages, followed by their representative applications. Further, the specific applications of developing SERS-based aptasensors in food safety are systematically provided. Moreover, the multiplex analysis using SERS labels are highlighted. Finally, challenges and perspectives for improving the SERS-based aptasensor performance are also discussed, aiming to give some proposes for researchers to choose suitable SERS-based aptasensors according to specific applications.
Collapse
Affiliation(s)
- Mengmeng Yan
- Institute of Quality Standard and Testing Technology for Agro-Products, Shandong Academy of Agricultural Sciences, Jinan, Shandong 250100, People's Republic of China
| | - Huidong Li
- Institute of Quality Standard and Testing Technology for Agro-Products, Shandong Academy of Agricultural Sciences, Jinan, Shandong 250100, People's Republic of China
| | - Min Li
- Institute of Quality Standard and Testing Technology for Agro-Products, Shandong Academy of Agricultural Sciences, Jinan, Shandong 250100, People's Republic of China
| | - Xiaolin Cao
- College of Life Science, Yantai University, Yantai, Shandong 264005, People's Republic of China
| | - Yongxin She
- Institute of Quality Standards and Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing 100081, People's Republic of China
| | - Zilei Chen
- Institute of Quality Standard and Testing Technology for Agro-Products, Shandong Academy of Agricultural Sciences, Jinan, Shandong 250100, People's Republic of China
| |
Collapse
|
36
|
Cheng S, Tu Z, Zheng S, Cheng X, Han H, Wang C, Xiao R, Gu B. An efficient SERS platform for the ultrasensitive detection of Staphylococcus aureus and Listeria monocytogenes via wheat germ agglutinin-modified magnetic SERS substrate and streptavidin/aptamer co-functionalized SERS tags. Anal Chim Acta 2021; 1187:339155. [PMID: 34753577 DOI: 10.1016/j.aca.2021.339155] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Accepted: 10/04/2021] [Indexed: 12/13/2022]
Abstract
A novel surface-enhanced Raman scattering (SERS)-based analytical technique was proposed to simultaneously detect two highly pathogenic bacteria, namely, Staphylococcus aureus (S. aureus) and Listeria monocytogenes (L. mono) by using a dual-recognition pattern with wheat germ agglutinin (WGA) and nucleic acid aptamers. WGA was modified onto Fe3O4@Au magnetic nanoparticles (MNPs) for the efficient capture of S. aureus and L. mono in complex samples (orange juice, extracts of lettuce, and human urine) within 15 min. The streptavidin (SA)/aptamers co-functionalized SERS tags were fabricated by covalent attaching two different Raman reporters and SA molecules onto 45 nm Au NPs and then conjugated with two biotin-aptamers that specifically bind to their target bacteria with high affinity and stability. The combined use of high-sensitive SERS tags, WGA-mediated magnetic enrichment, and SA-mediated aptamer conjugation remarkably improved the assay sensitivity. Under optimized conditions, the developed SERS biosensor can simultaneously detect the two target bacteria with high detection sensitivity (<6 cells/mL), favorable linear relation (10-107 cells/mL), and high accuracy (recovery rate <7.03%). Therefore, the proposed SERS platform is rapid, sensitive, easy to use, and thus show potential as a tool for the timely identification of pathogenic bacteria in real samples.
Collapse
Affiliation(s)
- Siyun Cheng
- Medical Technology School of Xuzhou Medical University, Xuzhou, 221004, PR China; Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Zhijie Tu
- Medical Technology School of Xuzhou Medical University, Xuzhou, 221004, PR China; Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Shuai Zheng
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China; College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
| | - Xiaodan Cheng
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China; College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
| | - Han Han
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Chongwen Wang
- Medical Technology School of Xuzhou Medical University, Xuzhou, 221004, PR China; Beijing Institute of Radiation Medicine, Beijing, 100850, PR China; College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China.
| | - Rui Xiao
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China.
| | - Bing Gu
- Medical Technology School of Xuzhou Medical University, Xuzhou, 221004, PR China; Laboratory Medicine, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510000, PR China.
| |
Collapse
|
37
|
Chia ZC, Yang LX, Cheng TY, Chen YJ, Cheng HL, Hsu FT, Wang YJ, Chen YY, Huang TC, Fang YS, Huang CC. In Situ Formation of Au-Glycopolymer Nanoparticles for Surface-Enhanced Raman Scattering-Based Biosensing and Single-Cell Immunity. ACS APPLIED MATERIALS & INTERFACES 2021; 13:52295-52307. [PMID: 34706531 DOI: 10.1021/acsami.1c13647] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Successful synthesis of glyconanoparticles has attracted much attention due to their various biointeractive capabilities, but it is still a challenge to understand different single-cell responses to exogenous particles among cell populations. Herein, we designed polyaniline-containing galactosylated gold nanoparticles (Au@PGlyco NPs) via in situ polymerization of ortho-nitrophenyl-β-galactoside assisted by Au nucleation. The nanogold-carrying polyaniline block produced electromagnetic enhancement in surface-enhanced Raman scattering (SERS). The underlying polymerization mechanism of ortho-nitrophenyl compounds via the formation of Au nanoparticles was investigated. Depending on how the galactoside moiety reacted with β-galactosidase derived from bacteria, the Au@PGlyco NPs-mediated SERS biosensor could detect low amounts of bacteria (∼1 × 102 CFU/mL). In addition, a high accumulation of Au@PGlyco NPs mediated the immune response of tumor-associated M2 macrophages to the immunogenic M1 macrophage transition, which was elicited by reactive oxygen levels biostimulation using single-cell SERS-combined fluorescence imaging. Our study suggested that Au@PGlyco NPs may serve as a biosensing platform with the labeling capacity on galactose-binding receptors expressed cell and immune regulation.
Collapse
Affiliation(s)
- Zi-Chun Chia
- Department of Photonics, National Cheng Kung University, Tainan 70101, Taiwan
| | - Li-Xing Yang
- Department of Photonics, National Cheng Kung University, Tainan 70101, Taiwan
| | - Ting-Yu Cheng
- Department of Photonics, National Cheng Kung University, Tainan 70101, Taiwan
| | - Ya-Jyun Chen
- Department of Photonics, National Cheng Kung University, Tainan 70101, Taiwan
| | - Horng-Long Cheng
- Department of Photonics, National Cheng Kung University, Tainan 70101, Taiwan
| | - Fei-Ting Hsu
- Department of Biological Science and Technology, China Medical University, Taichung 40402, Taiwan
| | - Ying-Jan Wang
- Department of Environmental and Occupational Health, National Cheng Kung University, Tainan 70101, Taiwan
| | - Yu-Ying Chen
- Department of Environmental and Occupational Health, National Cheng Kung University, Tainan 70101, Taiwan
| | - Tzu-Chi Huang
- Department of Photonics, National Cheng Kung University, Tainan 70101, Taiwan
| | - Yi-Syun Fang
- Department of Photonics, National Cheng Kung University, Tainan 70101, Taiwan
| | - Chih-Chia Huang
- Department of Photonics, National Cheng Kung University, Tainan 70101, Taiwan
- Center of Applied Nanomedicine, National Cheng Kung University, Tainan 70101, Taiwan
| |
Collapse
|
38
|
Trends in the bacterial recognition patterns used in surface enhanced Raman spectroscopy. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116310] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
39
|
Jia Z, Asiri S, Elsharif A, Alamoudi W, Al-Suhaimi E, Kim SG. Design of Inverted Nano-Cone Arrayed SERS Substrate for Rapid Detection of Pathogens. APPLIED SCIENCES 2021; 11:8067. [DOI: 10.3390/app11178067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/26/2024]
Abstract
Rapid detection of bacteria is a very critical and important part of infectious disease treatment. Sepsis kills more than 25 percent of its victims, resulting in as many as half of all deaths in hospitals before identifying the pathogen for patients to get the right treatment. Raman spectroscopy is a promising candidate in pathogen diagnosis given its fast and label-free nature, only if the concentration of the pathogen is high enough to provide reasonable sensitivity. This work reports a new design of surface-enhanced Raman spectroscopy (SERS) substrate which will provide high enough sensitivity and fast and close contact of the target structure to the optical hot spots for immunomagnetic capturing-based bacteria-concentrating technique. The substrate uses inverted nanocone structure arrays made of transparent PDMS (Polydimethylsiloxane) to funnel the light from the bottom to the top of the cones where plasmonic gold nanorods are located. A high reflective and low loss layer is deposited on the outer surface of the cone. Given the geometry of cones, photons are multi-reflected by the outer layer and thus the number density of photons at hotspots increases by an order of magnitude, which could be high enough to detect immunomagnetically densified bacteria.
Collapse
Affiliation(s)
- Zixun Jia
- Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA
| | - Sarah Asiri
- Department of Chemistry, College of Science, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia
| | - Asma Elsharif
- Department of Chemistry, College of Science, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia
| | - Widyan Alamoudi
- Biophysics Research Epidemic Research Department, Institute for Medical and Consultations (IRMC), Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia
| | - Ebtesam Al-Suhaimi
- Biology Department, College of Science, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia
| | - Sang-Gook Kim
- Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA
| |
Collapse
|
40
|
Sheikhzadeh E, Beni V, Zourob M. Nanomaterial application in bio/sensors for the detection of infectious diseases. Talanta 2021; 230:122026. [PMID: 33934756 PMCID: PMC7854185 DOI: 10.1016/j.talanta.2020.122026] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 12/14/2020] [Accepted: 12/15/2020] [Indexed: 02/07/2023]
Abstract
Infectious diseases are a potential risk for public health and the global economy. Fast and accurate detection of the pathogens that cause these infections is important to avoid the transmission of the diseases. Conventional methods for the detection of these microorganisms are time-consuming, costly, and not applicable for on-site monitoring. Biosensors can provide a fast, reliable, and point of care diagnostic. Nanomaterials, due to their outstanding electrical, chemical, and optical features, have become key players in the area of biosensors. This review will cover different nanomaterials that employed in electrochemical, optical, and instrumental biosensors for infectious disease diagnosis and how these contributed to enhancing the sensitivity and rapidity of the various sensing platforms. Examples of nanomaterial synthesis methods as well as a comprehensive description of their properties are explained. Moreover, when available, comparative data, in the presence and absence of the nanomaterials, have been reported to further highlight how the usage of nanomaterials enhances the performances of the sensor.
Collapse
Affiliation(s)
- Elham Sheikhzadeh
- Department of Chemistry, Faculty of Science, Ferdowsi University of Mashhad, Mashhad, Iran,Corresponding author
| | - Valerio Beni
- Digital Systems, Department Smart Hardware, Unit Bio–& Organic Electronics, RISE Acreo, Research Institutes of Sweden, Norrkoping, 60221, Sweden
| | - Mohammed Zourob
- Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh, 11533, Saudi Arabia,King Faisal Specialist Hospital and Research Center, Zahrawi Street, Al Maather, Riyadh, 12713, Saudi Arabia,Corresponding author. Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh, 11533, Saudi Arabia
| |
Collapse
|
41
|
Weng YW, Hu XD, Jiang L, Shi QL, Wei XL. An all-in-one magnetic SERS nanosensor for ratiometric detection of Escherichia coli in foods. Anal Bioanal Chem 2021; 413:5419-5426. [PMID: 34322738 DOI: 10.1007/s00216-021-03521-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 06/23/2021] [Accepted: 06/30/2021] [Indexed: 12/17/2022]
Abstract
An all-in-one nanosensor was developed for the magnetic enrichment and ratiometric surface-enhanced Raman scattering (SERS) detection of Escherichia coli (E. coli). The all-in-one nanosensor was constructed through the chemical integration of four components into a single nanoparticle, which include a manganese ferrite nanoparticle serving as the magnetic core, a thin silver shell as the SERS substrate, a self-assembled layer of 4-mercaptobenzoic acid (MBA) molecules as the SERS internal standard, and a MBA-conjugated layer of aptamer sequences as the capture probe of E. coli. In the detection of E. coli in food, the target cells were first captured by the nanosensors and magnetically enriched in a short time of 15 min, and then the ratiometric SERS was performed through the Raman intensity ratio between two specific SERS peaks produced by the captured E. coli and the internal MBA. The pre-concentration and ratiometry enabled the nanosensor to detect E. coli with a detection limit down to 10 CFU/mL. The all-in-one nanosensor was successfully applied for the detection of E. coli in various liquid foods including milk, juice, tea, and coffee, with recoveries ranging from 89 to 110% and relative standard deviation lower than 1.7%. In comparison with the previous sandwich strategy adopted by most SERS sensors, this nanosensor endowed with an easier use and a lower cost is more sensitive and reproducible, leading to a great potential in practical applications.
Collapse
Affiliation(s)
- Yi-Wei Weng
- Chongqing Key Laboratory of Catalysis and Functional Organic Molecule, College of Environment and Resources, Chongqing Technology and Business University, Chongqing, 400067, China
| | - Xiao-Di Hu
- Chongqing Key Laboratory of Catalysis and Functional Organic Molecule, College of Environment and Resources, Chongqing Technology and Business University, Chongqing, 400067, China
| | - Lan Jiang
- Chongqing Key Laboratory of Catalysis and Functional Organic Molecule, College of Environment and Resources, Chongqing Technology and Business University, Chongqing, 400067, China
| | - Qin-Ling Shi
- Chongqing Key Laboratory of Catalysis and Functional Organic Molecule, College of Environment and Resources, Chongqing Technology and Business University, Chongqing, 400067, China
| | - Xiao-Lan Wei
- Chongqing Key Laboratory of Catalysis and Functional Organic Molecule, College of Environment and Resources, Chongqing Technology and Business University, Chongqing, 400067, China.
| |
Collapse
|
42
|
Wu J, Zhou X, Li P, Lin X, Wang J, Hu Z, Zhang P, Chen D, Cai H, Niessner R, Haisch C, Sun P, Zheng Y, Jiang Z, Zhou H. Ultrasensitive and Simultaneous SERS Detection of Multiplex MicroRNA Using Fractal Gold Nanotags for Early Diagnosis and Prognosis of Hepatocellular Carcinoma. Anal Chem 2021; 93:8799-8809. [PMID: 34076420 DOI: 10.1021/acs.analchem.1c00478] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Sensitive and simultaneous detection of multiple cancer-related biomarkers in serum is essential for diagnosis, therapy, prognosis, and staging of cancer. Herein, we proposed a magnetically assisted sandwich-type surface-enhanced Raman scattering (SERS)-based biosensor for ultrasensitive and multiplex detection of three hepatocellular carcinoma-related microRNA (miRNA) biomarkers. The biosensor consists of an SERS tag (probe DNA-conjugated DNA-engineered fractal gold nanoparticles, F-AuNPs) and a magnetic capture substrate (capture DNA-conjugated Ag-coated magnetic nanoparticles, AgMNPs). The proposed strategy achieved simultaneous and sensitive detection of three miRNAs (miRNA-122, miRNA-223, and miRNA-21), and the limits of detection of the three miRNAs in human serum are 349 aM for miRNA-122, 374 aM for miRNA-223, and 311 aM for miRNA-21. High selectivity and accuracy of the SERS biosensor were proved by practical analysis in human serum. Moreover, the biosensor exhibited good practicability in multiplex detection of three miRNAs in 92 clinical sera from AFP-negative patients, patients before and after hepatectomy, recurred and relapse-free patients after hepatectomy, and hepatocellular carcinoma patients at distinct Barcelona clinic liver cancer stages. The experiment results demonstrate that our SERS-based assay is a promising candidate in clinical application and exhibited potential for the prediction, diagnosis, monitoring, and staging of cancers.
Collapse
Affiliation(s)
- Jiamin Wu
- College of Pharmacy, Jinan University, Guangzhou, Guangdong 510632, China
| | - Xia Zhou
- College of Pharmacy, Jinan University, Guangzhou, Guangdong 510632, China
| | - Ping Li
- College of Pharmacy, Jinan University, Guangzhou, Guangdong 510632, China
| | - Xiaoling Lin
- College of Pharmacy, Jinan University, Guangzhou, Guangdong 510632, China
| | - Jinhua Wang
- College of Pharmacy, Jinan University, Guangzhou, Guangdong 510632, China
| | - Ziwei Hu
- College of Pharmacy, Jinan University, Guangzhou, Guangdong 510632, China
| | - Pengcheng Zhang
- College of Chemistry and Chemical Engineering, Zhoukou Normal University, Zhoukou, Henan 466000, China
| | - Dong Chen
- State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, Guangdong 510060, China
| | - Huaihong Cai
- College of Chemistry and Materials Science, Jinan University, Guangzhou, Guangdong 510632, China
| | - Reinhard Niessner
- Institute of Hydrochemistry and Chair for Analytical Chemistry, Technical University of Munich, Marchioninistr. 17, Munich D-81377, Germany
| | - Christoph Haisch
- Institute of Hydrochemistry and Chair for Analytical Chemistry, Technical University of Munich, Marchioninistr. 17, Munich D-81377, Germany
| | - Pinghua Sun
- College of Pharmacy, Jinan University, Guangzhou, Guangdong 510632, China
| | - Yun Zheng
- State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, Guangdong 510060, China
| | - Zhengjin Jiang
- College of Pharmacy, Jinan University, Guangzhou, Guangdong 510632, China
| | - Haibo Zhou
- College of Pharmacy, Jinan University, Guangzhou, Guangdong 510632, China
| |
Collapse
|
43
|
Qu LL, Ying YL, Yu RJ, Long YT. In situ food-borne pathogen sensors in a nanoconfined space by surface enhanced Raman scattering. Mikrochim Acta 2021; 188:201. [PMID: 34041602 PMCID: PMC8154335 DOI: 10.1007/s00604-021-04864-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Accepted: 05/13/2021] [Indexed: 01/04/2023]
Abstract
The incidence of disease arising from food-borne pathogens is increasing continuously and has become a global public health problem. Rapid and accurate identification of food-borne pathogens is essential for adopting disease intervention strategies and controlling the spread of epidemics. Surface-enhanced Raman spectroscopy (SERS) has attracted increasing interest due to the attractive features including simplicity, rapid measurement, and high sensitivity. It can be used for rapid in situ sensing of single and multicomponent samples within the nanostructure-based confined space by providing molecular fingerprint information and has been demonstrated to be an effective detection strategy for pathogens. This article aims to review the application of SERS to the rapid sensing of food-borne pathogens in food matrices. The mechanisms and advantages of SERS, and detection strategies are briefly discussed. The latest progress on the use of SERS for rapid detection of food-borne bacteria and viruses is considered, including both the labeled and label-free detection strategies. In closing, according to the current situation regarding detection of food-borne pathogens, the review highlights the challenges faced by SERS and the prospects for new applications in food safety. In this review, the advances on the SERS detection of pathogens over the past decades have been reviewed, focusing on the improvements in sensitivity, reproducibility, specificity, and the performance of the SERS-based assay in complex analytical scenarios. ![]()
Collapse
Affiliation(s)
- Lu-Lu Qu
- School of Chemistry and Materials Science, Jiangsu Normal University, 221116, Xuzhou, People's Republic of China.
| | - Yi-Lun Ying
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, People's Republic of China
| | - Ru-Jia Yu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, People's Republic of China.
| | - Yi-Tao Long
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, People's Republic of China
| |
Collapse
|
44
|
Singhal C, Bruno JG, Kaushal A, Sharma TK. Recent Advances and a Roadmap to Aptamer-Based Sensors for Bloodstream Infections. ACS APPLIED BIO MATERIALS 2021; 4:3962-3984. [PMID: 35006817 DOI: 10.1021/acsabm.0c01358] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The present review is intended to describe bloodstream infections (BSIs), the major pathogens responsible for BSIs, conventional tests and their limitations, commercially available methods used, and the aptamer and nanomaterials-based approaches developed so far for the detection of BSIs. The advantages associated with aptamers and the aptamer-based sensors, the comparison between the aptamers and the antibodies, and the various types of aptasensors developed so far for the detection of bloodstream infections have been described in detail in the present review. Also, the future outlook and roadmap toward aptamer-based sensors and the challenges associated with the aptamer development have also been concluded in this review.
Collapse
Affiliation(s)
- Chaitali Singhal
- Aptamer Technology and Diagnostic Laboratory, Multidisciplinary Clinical and Translational Research Group, Translational Health Science and Technology Institute (THSTI), Faridabad, Haryana 121001, India
| | - John G Bruno
- Nanohmics, Inc., Austin, Texas 78741, United States
| | - Ankur Kaushal
- Centre of Nanotechnology, Amity University, Manesar, Gurugram, Haryana 122413, India
| | - Tarun K Sharma
- Aptamer Technology and Diagnostic Laboratory, Multidisciplinary Clinical and Translational Research Group, Translational Health Science and Technology Institute (THSTI), Faridabad, Haryana 121001, India
| |
Collapse
|
45
|
Lu T, Wang L, Xia Y, Jin Y, Zhang L, Du S. A multimer-based SERS aptasensor for highly sensitive and homogeneous assay of carcinoembryonic antigens. Analyst 2021; 146:3016-3024. [PMID: 33949429 DOI: 10.1039/d1an00121c] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Carcinoembryonic antigens (CEAs) are known as one of the most common tumor markers. Their facile and affordable detection is critical for early diagnosis of malignant tumors, especially in resource-constrained settings. Here, we report a novel multimer-based surface-enhanced Raman scattering (SERS) aptasensor for a specific CEA assay. The aptasensor is fabricated through aptamer-assisted self-assembly of silver-coated gold nanoparticles (Au@Ag NPs), and the self-assembled multimeric structure possesses abundant hot-spots to provide high SERS response. When CEA is introduced, the specific recognition of CEA by aptamers will lead to the disassembly of Au@Ag multimers due to the lack of a bridging aptamer between Au@Ag NPs. As a result, the number of hot-spots in the multimeric system is decreased, and the intensity at 1585 cm-1 of the SERS reporter (4-mercaptobenzoic acid, 4-MBA) on the surface of NPs will also be decreased. The Raman intensity is proportional to the logarithm of the concentration of CEA. The detection sensitivity can be down to the pg mL-1 level. The analytical method only needs a droplet of 2 μL of sample, and the detection time is less than 20 min. The multimer-based SERS aptasensor can be applied in sensitive and inexpensive detection of CEA in serum samples.
Collapse
Affiliation(s)
- Tian Lu
- School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu 211166, China.
| | - Liping Wang
- School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu 211166, China.
| | - Yuhong Xia
- School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu 211166, China.
| | - Yang Jin
- School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu 211166, China.
| | - Liying Zhang
- School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu 211166, China.
| | - Shuhu Du
- School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu 211166, China.
| |
Collapse
|
46
|
Huynh KH, Hahm E, Noh MS, Lee JH, Pham XH, Lee SH, Kim J, Rho WY, Chang H, Kim DM, Baek A, Kim DE, Jeong DH, Park SM, Jun BH. Recent Advances in Surface-Enhanced Raman Scattering Magnetic Plasmonic Particles for Bioapplications. NANOMATERIALS 2021; 11:nano11051215. [PMID: 34064407 PMCID: PMC8147842 DOI: 10.3390/nano11051215] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 04/25/2021] [Accepted: 04/30/2021] [Indexed: 01/10/2023]
Abstract
The surface-enhanced Raman scattering (SERS) technique, that uses magnetic plasmonic particles (MPPs), is an advanced SERS detection platform owing to the synergetic effects of the particles’ magnetic and plasmonic properties. As well as being an ultrasensitive and reliable SERS material, MPPs perform various functions, such as aiding in separation, drug delivery, and acting as a therapeutic material. This literature discusses the structure and multifunctionality of MPPs, which has enabled the novel application of MPPs to various biological fields.
Collapse
Affiliation(s)
- Kim-Hung Huynh
- Department of Bioscience and Biotechnology, Konkuk University,120 Neungdong-ro, Gwangjin-Gu, Seoul 05029, Korea; (K.-H.H.); (E.H.); (X.-H.P.); (J.K.); (D.M.K.); (A.B.); (D.-E.K.)
| | - Eunil Hahm
- Department of Bioscience and Biotechnology, Konkuk University,120 Neungdong-ro, Gwangjin-Gu, Seoul 05029, Korea; (K.-H.H.); (E.H.); (X.-H.P.); (J.K.); (D.M.K.); (A.B.); (D.-E.K.)
| | - Mi Suk Noh
- Medical Device & Bio-research Team, Bio-medical & Environ-chemical Division, Korea Testing Certification, Gunpo, Gyeonggi-do 15809, Korea;
| | - Jong-Hwan Lee
- Center for Convergent Research of Emerging Virus Infection, Korea Research Institute of Chemical Technology, Daejeon 34114, Korea;
| | - Xuan-Hung Pham
- Department of Bioscience and Biotechnology, Konkuk University,120 Neungdong-ro, Gwangjin-Gu, Seoul 05029, Korea; (K.-H.H.); (E.H.); (X.-H.P.); (J.K.); (D.M.K.); (A.B.); (D.-E.K.)
| | - Sang Hun Lee
- Department of Chemical and Biological Engineering, Hanbat National University, 125 Dongseo-daero, Yuseong-gu, Daejeon 34158, Korea;
| | - Jaehi Kim
- Department of Bioscience and Biotechnology, Konkuk University,120 Neungdong-ro, Gwangjin-Gu, Seoul 05029, Korea; (K.-H.H.); (E.H.); (X.-H.P.); (J.K.); (D.M.K.); (A.B.); (D.-E.K.)
| | - Won-Yeop Rho
- School of International Engineering and Science, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si, Jeollabuk-do 54896, Korea;
| | - Hyejin Chang
- Division of Science Education, Kangwon National University, 1 Gangwondaehakgil, Chuncheon-si, Gangwon-do 24341, Korea;
| | - Dong Min Kim
- Department of Bioscience and Biotechnology, Konkuk University,120 Neungdong-ro, Gwangjin-Gu, Seoul 05029, Korea; (K.-H.H.); (E.H.); (X.-H.P.); (J.K.); (D.M.K.); (A.B.); (D.-E.K.)
| | - Ahruem Baek
- Department of Bioscience and Biotechnology, Konkuk University,120 Neungdong-ro, Gwangjin-Gu, Seoul 05029, Korea; (K.-H.H.); (E.H.); (X.-H.P.); (J.K.); (D.M.K.); (A.B.); (D.-E.K.)
| | - Dong-Eun Kim
- Department of Bioscience and Biotechnology, Konkuk University,120 Neungdong-ro, Gwangjin-Gu, Seoul 05029, Korea; (K.-H.H.); (E.H.); (X.-H.P.); (J.K.); (D.M.K.); (A.B.); (D.-E.K.)
| | - Dae Hong Jeong
- Department of Chemistry Education, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Korea;
- Center for Educational Research, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Korea
| | - Seung-min Park
- Department of Urology, Department of Radiology, Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA 94305, USA
- Correspondence: (S.-m.P.); (B.-H.J.); Tel.: +82-2-450-0521 (B.-H.J.)
| | - Bong-Hyun Jun
- Department of Bioscience and Biotechnology, Konkuk University,120 Neungdong-ro, Gwangjin-Gu, Seoul 05029, Korea; (K.-H.H.); (E.H.); (X.-H.P.); (J.K.); (D.M.K.); (A.B.); (D.-E.K.)
- Correspondence: (S.-m.P.); (B.-H.J.); Tel.: +82-2-450-0521 (B.-H.J.)
| |
Collapse
|
47
|
Zhang H, Yao S, Song X, Xu K, Wang J, Li J, Zhao C, Jin M. One-step colorimetric detection of Staphylococcus aureus based on target-induced shielding against the peroxidase mimicking activity of aptamer-functionalized gold-coated iron oxide nanocomposites. Talanta 2021; 232:122448. [PMID: 34074432 DOI: 10.1016/j.talanta.2021.122448] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2021] [Revised: 04/04/2021] [Accepted: 04/18/2021] [Indexed: 12/30/2022]
Abstract
Staphylococcus aureus (S. aureus) is one of the most threatened food-borne pathogens. Thus, it is necessary to establish fast, portable and reliable tools to realize the identification of S. aureus. Herein, the authors describe an effective colorimetric-based biosensor for the detection of S. aureus in multiple types of samples. Initially, a nanozyme composed of gold and iron oxide nanoparticles was synthesized and further modified with S. aureus-specific aptamer via Au-S bond. By utilizing the intrinsic peroxidase-like activity of the above magnetic conjugates, 3,3',5,5'-tetramethylbenzidine (TMB) can be transferred to oxTMB by oxidation of hydrogen peroxide (H2O2), resulting in a visible blue color. However, the introduction of S. aureus can turn off the UV-vis absorbance signals of TMB-H2O2 system, due to the identification property of the nanozyme probe. Consequently, the optical density of the mixed solution measured at 652 nm decreased linearly as the concentration of S. aureus increased from 10 to 106 CFU mL-1, with the visible limit of detection as low as 10 CFU mL-1. The as-prepared sensor can detect S. aureus in spiked water, milk and urine samples quantitatively during 12 min without any pre-enrichment, separation or washing steps. In our perception, the one-step colorimetric assay show promise in practical on-site detection of S. aureus.
Collapse
Affiliation(s)
- Huiwen Zhang
- School of Public Health, Jilin University, Changchun, 130021, China
| | - Shuo Yao
- School of Public Health, Jilin University, Changchun, 130021, China
| | - Xiuling Song
- School of Public Health, Jilin University, Changchun, 130021, China
| | - Kun Xu
- School of Public Health, Jilin University, Changchun, 130021, China
| | - Juan Wang
- School of Public Health, Jilin University, Changchun, 130021, China
| | - Juan Li
- School of Public Health, Jilin University, Changchun, 130021, China.
| | - Chao Zhao
- School of Public Health, Jilin University, Changchun, 130021, China.
| | - Minghua Jin
- School of Public Health, Jilin University, Changchun, 130021, China.
| |
Collapse
|
48
|
Busch RT, Karim F, Sun Y, Fry HC, Liu Y, Zhao C, Vasquez ES. Detection and Aggregation of Listeria Monocytogenes Using Polyclonal Antibody Gold-Coated Magnetic Nanoshells Surface-Enhanced Raman Spectroscopy Substrates. FRONTIERS IN NANOTECHNOLOGY 2021. [DOI: 10.3389/fnano.2021.653744] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Magnetic nanoshells with tailored surface chemistry can enhance bacterial detection and separation technologies. This work demonstrated a simple technique to detect, capture, and aggregate bacteria with the aid of end-functionalized polyclonal antibody gold-coated magnetic nanoshells (pAb-Lis-AuMNs) as surface-enhanced Raman spectroscopy (SERS) probes. Listeria monocytogenes were used as the pathogenic bacteria and the pAb-Lis-AuMNs, 300 nm diameter, were used as probes allowing facile magnetic separation and aggregation. An optimized covalent bioconjugation procedure between the magnetic nanoshells and the polyclonal antibody was performed at pH six via a carbodiimide crosslinking reaction. Spectroscopic and morphological characterization techniques confirmed the fabrication of stable pAb-Lis-AuMNs. The resulting pAb-Lis-AuMNs acted as a SERS probe for L. monocytogenes based on the targeted capture via surface binding interactions and magnetically induced aggregation. Label-free SERS measurements were recorded for the minimum detectable amount of L. monocytogenes based on the SERS intensity at the 1388 cm−1 Raman shift. L. monocytogenes concentrations exhibited detection limits in the range of 104–107 CFU ml−1, before and after aggregation. By fitting these concentrations, the limit of detection of this method was ∼103 CFU ml−1. Using a low-intensity magnetic field of 35 G, pAb-Lis-AuMNs aggregated L. monocytogenes as demonstrated with microscopy techniques, including SEM and optical microscopy. Overall, this work presents a label-free SERS probe method comprised of a surface-modified polyclonal antibody sub-micron magnetic nanoshell structures with high sensitivity and magnetic induced separation that could lead to the fabrication of multiple single-step sensors.
Collapse
|
49
|
Wang S, Shen W, Zheng S, Li Z, Wang C, Zhang L, Liu Y. Dual-signal lateral flow assay using vancomycin-modified nanotags for rapid and sensitive detection of Staphylococcus aureus. RSC Adv 2021; 11:13297-13303. [PMID: 35423879 PMCID: PMC8697553 DOI: 10.1039/d1ra01085a] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 03/28/2021] [Indexed: 12/17/2022] Open
Abstract
This paper reports a colorimetric-fluorescent dual-signal lateral flow assay (LFA) based on vancomycin (Van)-modified SiO2-Au-QD tags for sensitive and quantitative detection of Staphylococcus aureus (S. aureus). The combination of high-performance Van-tags and detection antibodies integrated into the LFA system produced assays with high sensitivity and specificity. The visualization limit of the colorimetric signal and the detection limit of the fluorescence signal of the proposed method for S. aureus can reach 104 and 100 cells mL-1, respectively.
Collapse
Affiliation(s)
- Shu Wang
- Hefei Institute of Physical Science, Chinese Academy of Sciences Hefei 230036 PR China
- University of Science and Technology of China Hefei 230036 PR China
| | - Wanzhu Shen
- Anhui Agricultural University Hefei 230036 PR China
- Beijing Institute of Radiation Medicine Beijing 100850 PR China
| | - Shuai Zheng
- Anhui Agricultural University Hefei 230036 PR China
- Beijing Institute of Radiation Medicine Beijing 100850 PR China
| | - Zhigang Li
- Hefei Institute of Physical Science, Chinese Academy of Sciences Hefei 230036 PR China
| | - Chongwen Wang
- Anhui Agricultural University Hefei 230036 PR China
- Beijing Institute of Radiation Medicine Beijing 100850 PR China
| | - Long Zhang
- Hefei Institute of Physical Science, Chinese Academy of Sciences Hefei 230036 PR China
- University of Science and Technology of China Hefei 230036 PR China
| | - Yong Liu
- Hefei Institute of Physical Science, Chinese Academy of Sciences Hefei 230036 PR China
- University of Science and Technology of China Hefei 230036 PR China
| |
Collapse
|
50
|
Zhou Z, Xiao R, Cheng S, Wang S, Shi L, Wang C, Qi K, Wang S. A universal SERS-label immunoassay for pathogen bacteria detection based on Fe 3O 4@Au-aptamer separation and antibody-protein A orientation recognition. Anal Chim Acta 2021; 1160:338421. [PMID: 33894956 DOI: 10.1016/j.aca.2021.338421] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Revised: 03/12/2021] [Accepted: 03/13/2021] [Indexed: 12/26/2022]
Abstract
Rapid, reliable and sensitive detection methods for pathogenic bacteria are strongly demanded. Herein, we proposed a magnetically assisted surface enhanced Raman scattering (SERS)-label immunoassay for the sensitive detection of bacteria by using a universal approach based on free antibody labelling and staphylococcus proteins A (PA)-SERS tags orientation recognition. The SERS biosensor consists of two functional nanomaterials: aptamer-conjugated Fe3O4@Au magnetic nanoparticles (MNPs) as magnetic SERS platform for pathogen enrichment and PA modified-SERS tags (Au@DTNB@PA) as a universal probe for target bacteria quantitative detection. After target bacteria enriched, free antibody was used to specific marking target bacteria and provided numerous Fc fragment, which can guide the PA-SERS tags orientation-dependent binding. With this strategy, Fe3O4@Au/bacteria/SERS tags sandwich immunocomplexes for most bacteria (expect several species of Staphylococcus) were easy constructed. The limits of detection (LODs) of the proposed assay were found to be 10, 10, and 25 cells/mL for three common pathogens Escherichia coli (E. coli), Listeria monocytogenes (L. mono), and Salmonella typhimurium (S. typhi), respectively, in real food samples. The universal method also exhibits the advantages of rapid, robust, and easy to operate, suggesting its great potential for food safety monitoring and infectious diseases diagnosis.
Collapse
Affiliation(s)
- Zihui Zhou
- Anhui Agricultural University, Hefei, 230036, PR China; Beijing Institute of Radiation Medicine, Beijing, 100850, PR China; Anhui Province Engineering Laboratory for Animal Food Quality and Bio-safety, College of Animal Science and Technology, Anhui Agricultural University, Hefei, 230036, PR China
| | - Rui Xiao
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Siyun Cheng
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Shu Wang
- Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei, 230036, PR China
| | - Luoluo Shi
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Chongwen Wang
- Anhui Agricultural University, Hefei, 230036, PR China; Beijing Institute of Radiation Medicine, Beijing, 100850, PR China.
| | - Kezong Qi
- Anhui Agricultural University, Hefei, 230036, PR China; Anhui Province Key Laboratory of Veterinary Pathobiology and Disease Control, Hefei, 230036, PR China; Anhui Province Engineering Laboratory for Animal Food Quality and Bio-safety, College of Animal Science and Technology, Anhui Agricultural University, Hefei, 230036, PR China.
| | - Shengqi Wang
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China.
| |
Collapse
|