1
|
Xue R, Deng X, Xu X, Tian Y, Hasan A, Mata A, Zhang L, Liu L. Elastin-like recombinamer-mediated hierarchical mineralization coatings on Zr-16Nb-xTi (x = 4,16 wt%) alloy surfaces improve biocompatibility. BIOMATERIALS ADVANCES 2023; 151:213471. [PMID: 37201355 DOI: 10.1016/j.bioadv.2023.213471] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 03/21/2023] [Accepted: 05/09/2023] [Indexed: 05/20/2023]
Abstract
The biocompatibility of biomedical materials is vital to their applicability and functionality. However, modifying surfaces for enhanced biocompatibility using traditional surface treatment techniques is challenging. We employed a mineralizing elastin-like recombinamer (ELR) self-assembling platform to mediate mineralization on Zr-16Nb-xTi (x = 4,16 wt%) alloy surfaces, resulting in the modification of surface morphology and bioactivity while improving the biocompatibility of the material. We modulated the level of nanocrystal organization by adjusting the cross-linker ratio. Nanoindentation tests revealed that the mineralized configuration had nonuniformity with respect to Young's modulus and hardness, with the center areas having higher values (5.626 ± 0.109 GPa and 0.264 ± 0.022 GPa) compared to the edges (4.282 ± 0.327 GPa and 0.143 ± 0.023 GPa). The Scratch test results indicated high bonding strength (2.668 ± 0.117 N) between the mineralized coating and the substrate. Mineralized Zr-16Nb-xTi (x = 4,16 wt%) alloys had higher viability compared to untreated alloys, which exhibited high cell viability (>100 %) after 5 days and high alkaline phosphatase activity after 7 days. Cell proliferation assays indicated that MG 63 cells grew faster on mineralized surfaces than on untreated surfaces. Scanning electron microscopy imaging confirmed that the cells adhered and spread well on mineralized surfaces. Furthermore, hemocompatibility test results revealed that all mineralized samples were non-hemolytic. Our results demonstrate the viability of employing the ELR mineralizing platform to improve alloy biocompatibility.
Collapse
Affiliation(s)
- Renhao Xue
- School of Materials Science and Engineering, Central South University, Changsha, Hunan 410083, PR China; State Key Laboratory of Powder Metallurgy, Central South University, Changsha, Hunan 410083, PR China
| | - Xinru Deng
- School of Engineering and Materials Science, Queen Mary University of London, London E14NS, UK
| | - Xiaoning Xu
- School of Materials Science and Engineering, Central South University, Changsha, Hunan 410083, PR China; State Key Laboratory of Powder Metallurgy, Central South University, Changsha, Hunan 410083, PR China
| | - Yueyan Tian
- School of Materials Science and Engineering, Central South University, Changsha, Hunan 410083, PR China; State Key Laboratory of Powder Metallurgy, Central South University, Changsha, Hunan 410083, PR China
| | - Abshar Hasan
- School of Pharmacy, University of Nottingham, Nottingham NG7 2RD, UK; Biodiscovery Institute, University of Nottingham, Nottingham NG7 2RD, UK
| | - Alvaro Mata
- School of Pharmacy, University of Nottingham, Nottingham NG7 2RD, UK; Biodiscovery Institute, University of Nottingham, Nottingham NG7 2RD, UK; Department of Chemical & Environmental Engineering, University of Nottingham, Nottingham NG7 2RD, UK
| | - Ligang Zhang
- School of Materials Science and Engineering, Central South University, Changsha, Hunan 410083, PR China; State Key Laboratory of Powder Metallurgy, Central South University, Changsha, Hunan 410083, PR China.
| | - Libin Liu
- School of Materials Science and Engineering, Central South University, Changsha, Hunan 410083, PR China; State Key Laboratory of Powder Metallurgy, Central South University, Changsha, Hunan 410083, PR China.
| |
Collapse
|
2
|
Costa RC, Nagay BE, Dini C, Borges MHR, Miranda LFB, Cordeiro JM, Souza JGS, Sukotjo C, Cruz NC, Barão VAR. The race for the optimal antimicrobial surface: perspectives and challenges related to plasma electrolytic oxidation coating for titanium-based implants. Adv Colloid Interface Sci 2023; 311:102805. [PMID: 36434916 DOI: 10.1016/j.cis.2022.102805] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 10/01/2022] [Accepted: 10/20/2022] [Indexed: 01/24/2023]
Abstract
Plasma electrolytic oxidation (PEO) is a low-cost, structurally reliable, and environmentally friendly surface modification method for orthopedic and dental implants. This technique is successful for the formation of porous, corrosion-resistant, and bioactive coatings, besides introducing antimicrobial compounds easily. Given the increase in implant-related infections, antimicrobial PEO-treated surfaces have been widely proposed to surmount this public health concern. This review comprehensively discusses antimicrobial implant surfaces currently produced by PEO in terms of their in vitro and in vivo microbiological and biological properties. We present a critical [part I] and evidence-based [part II] review about the plethora of antimicrobial PEO-treated surfaces. The mechanism of microbial accumulation on implanted devices and the principles of PEO technology to ensure antimicrobial functionalization by one- or multi-step processes are outlined. Our systematic literature search showed that particular focus has been placed on the metallic and semi-metallic elements incorporated into PEO surfaces to facilitate antimicrobial properties, which are often dose-dependent, without leading to cytotoxicity in vitro. Meanwhile, there are concerns over the biocompatibility of PEO and its long-term antimicrobial effects in animal models. We clearly highlight the importance of using clinically relevant infection models and in vivo long-term assessments to guarantee the rational design of antimicrobial PEO-treated surfaces to identify the 'finish line' in the race for antimicrobial implant surfaces.
Collapse
Affiliation(s)
- Raphael C Costa
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sāo Paulo 13414-903, Brazil
| | - Bruna E Nagay
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sāo Paulo 13414-903, Brazil
| | - Caroline Dini
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sāo Paulo 13414-903, Brazil
| | - Maria H R Borges
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sāo Paulo 13414-903, Brazil
| | - Luís F B Miranda
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sāo Paulo 13414-903, Brazil
| | - Jairo M Cordeiro
- Department of Dentistry, Centro Universitário das Faculdades Associadas de Ensino (UNIFAE), Sāo Joāo da Boa Vista, Sāo Paulo 13870-377, Brazil
| | - Joāo G S Souza
- Dental Research Division, Guarulhos University, Guarulhos, Sāo Paulo 07023-070, Brazil; Dentistry Science School (Faculdade de Ciências Odontológicas - FCO), Montes Claros, Minas Gerais 39401-303, Brazil
| | - Cortino Sukotjo
- Department of Restorative Dentistry, University of Illinois at Chicago College of Dentistry, Chicago, IL 60612, USA
| | - Nilson C Cruz
- Laboratory of Technological Plasmas, Institute of Science and Technology, Sāo Paulo State University (UNESP), Sorocaba, Sāo Paulo 18087-180, Brazil
| | - Valentim A R Barão
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sāo Paulo 13414-903, Brazil.
| |
Collapse
|
3
|
Ye J, Li B, Li M, Zheng Y, Wu S, Han Y. Formation of a ZnO nanorods-patterned coating with strong bactericidal capability and quantitative evaluation of the contribution of nanorods-derived puncture and ROS-derived killing. Bioact Mater 2021; 11:181-191. [PMID: 34938922 PMCID: PMC8665260 DOI: 10.1016/j.bioactmat.2021.09.019] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Revised: 08/21/2021] [Accepted: 09/07/2021] [Indexed: 11/29/2022] Open
Abstract
To endow Ti-based orthopedic implants with strong bactericidal activity, a ZnO nanorods-patterned coating (namely ZNR) was fabricated on Ti utilizing a catalyst- and template-free method of micro-arc oxidation (MAO) and hydrothermal treatment (HT). The coating comprises an outer layer of ZnO nanorods and a partially crystallized inner layer with nanocrystalline TiO2 and Zn2TiO4 embedded amorphous matrix containing Ti, O and Zn. During HT, Zn2+ ions contained in amorphous matrix of the as-MAOed layer migrate to surface and react with OH− in hydrothermal solution to form ZnO nuclei growing in length at expense of the migrated Zn2+. ZNR exhibits intense bactericidal activity against the adhered and planktonic S. aureus in vitro and in vivo. The crucial contributors to kill the adhered bacteria are ZnO nanorods derived mechano-penetration and released reactive oxygen species (ROS). Within 30 min of S. aureus incubation, ROS is the predominant bactericidal contributor with quantitative contribution value of ∼20%, which transforms into mechano-penetration with prolonging time to reach quantitative contribution value of ∼96% at 24 h. In addition, the bactericidal contributor against the planktonic bacteria of ZNR is relied on the released Zn2+. This work discloses an in-depth bactericidal mechanism of ZnO nanorods. A templates and catalysts-free method is used to fabricate ZnO nanorods on Ti ZnO nanorods-arrayed coating shows intense broad-spectrum bactericidal activity Main bactericidal contributor of ZnO nanorods to adhered bacteria is mechano-puncture Main bactericidal contributor of ZnO nanorods to planktonic bacteria is released Zn2+
Collapse
Affiliation(s)
- Jing Ye
- State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, Xi'an, 710049, China
| | - Bo Li
- State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, Xi'an, 710049, China
| | - Mei Li
- State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, Xi'an, 710049, China.,Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510080, China
| | - Yufeng Zheng
- Center for Biomedical Materials and Tissue Engineering, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, 100871, China
| | - Shuilin Wu
- School of Materials Science & Engineering, The Key Laboratory of Advanced Ceramics and Machining Technology By the Ministry of Education of China, Tianjin University, Tianjin, 300072, China
| | - Yong Han
- State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, Xi'an, 710049, China
| |
Collapse
|
4
|
Sun Y, Yang Y, Jiang W, Bai H, Liu H, Wang J. In Vivo Antibacterial Efficacy of Nanopatterns on Titanium Implant Surface: A Systematic Review of the Literature. Antibiotics (Basel) 2021; 10:antibiotics10121524. [PMID: 34943736 PMCID: PMC8698789 DOI: 10.3390/antibiotics10121524] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Revised: 12/04/2021] [Accepted: 12/10/2021] [Indexed: 12/23/2022] Open
Abstract
Background: Bionic surface nanopatterns of titanium (Ti) materials have excellent antibacterial effects in vitro for infection prevention. To date, there is a lack of knowledge about the in vivo bactericidal outcomes of the nanostructures on the Ti implant surfaces. Methods: A systematic review was performed using the PubMed, Embase, and Cochrane databases to better understand surface nanoscale patterns’ in vivo antibacterial efficacy. The inclusion criteria were preclinical studies (in vivo) reporting the antibacterial activity of nanopatterns on Ti implant surface. Ex vivo studies, studies not evaluating the antibacterial activity of nanopatterns or surfaces not modified with nanopatterns were excluded. Results: A total of five peer-reviewed articles met the inclusion criteria. The included studies suggest that the in vivo antibacterial efficacy of the nanopatterns on Ti implants’ surfaces seems poor. Conclusions: Given the small number of literature results, the variability in experimental designs, and the lack of reporting across studies, concluding the in vivo antibacterial effectiveness of nanopatterns on Ti substrates’ surfaces remains a big challenge. Surface coatings using metallic or antibiotic elements are still practical approaches for this purpose. High-quality preclinical data are still needed to investigate the in vivo antibacterial effects of the nanopatterns on the implant surface.
Collapse
Affiliation(s)
- Yang Sun
- Orthopaedic Medical Center, The Second Hospital of Jilin University, Changchun 130041, China; (Y.S.); (Y.Y.); (W.J.); (H.B.); (H.L.)
| | - Yang Yang
- Orthopaedic Medical Center, The Second Hospital of Jilin University, Changchun 130041, China; (Y.S.); (Y.Y.); (W.J.); (H.B.); (H.L.)
- Engineering Research Centre of Molecular Diagnosis and Cell Treatment for Metabolic Bone Disease, The Second Hospital of Jilin University, Changchun 130041, China
| | - Weibo Jiang
- Orthopaedic Medical Center, The Second Hospital of Jilin University, Changchun 130041, China; (Y.S.); (Y.Y.); (W.J.); (H.B.); (H.L.)
| | - Haotian Bai
- Orthopaedic Medical Center, The Second Hospital of Jilin University, Changchun 130041, China; (Y.S.); (Y.Y.); (W.J.); (H.B.); (H.L.)
| | - He Liu
- Orthopaedic Medical Center, The Second Hospital of Jilin University, Changchun 130041, China; (Y.S.); (Y.Y.); (W.J.); (H.B.); (H.L.)
| | - Jincheng Wang
- Orthopaedic Medical Center, The Second Hospital of Jilin University, Changchun 130041, China; (Y.S.); (Y.Y.); (W.J.); (H.B.); (H.L.)
- Correspondence:
| |
Collapse
|
5
|
Eco-friendly bacteria-killing by nanorods through mechano-puncture with top selectivity. Bioact Mater 2021; 15:173-184. [PMID: 35386355 PMCID: PMC8941167 DOI: 10.1016/j.bioactmat.2021.11.028] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 11/25/2021] [Accepted: 11/25/2021] [Indexed: 11/20/2022] Open
Abstract
Nanorods can induce mechano-puncture of Staphylococcus aureus (S. aureus) that often impairs osseointegration of orthopedic implants, while the critical nanorod top sharpness able to puncture S. aureus and the predominant contributor between top sharpness and length to mechano-puncture activity remains elusive. Herein, we fabricated three kinds of Al2O3-wrapped nanorods patterned arrays with different lengths and top sharpness. The top-sharp nanorods have lengths of 469 and 884 nm and the shorter show a length identical to the top-flat nanorods. Driven by the equivalent adhesive force of S. aureus, the top-flat nanorods deform cell envelops, showing a bacteriostatic rate of 29% owing to proliferation-inhibited manner. The top-sharp nanorods puncture S. aureus, showing a bactericidal rate of 96% for the longer, and 98% for the shorter that simultaneously exhibits fair osseointegration in bacteria-infected rat tibias, identifying top sharpness as a predominate contributor to mechano-puncture activity. Based on finite-element simulation, such top-flat nanorod derives the maximum stress (Smax) of 5.65 MPa on cell wall, lower than its ultimate-tensile-strength (13 MPa); while such top-sharp and shorter nanorod derives Smax of 20.15 MPa to puncture cell envelop. Moreover, a critical top conical angle of 138° is identified for nanorods able to puncture S. aureus. Top sharpness depended mechano-puncture of nanorods against S. aureus is clarified. Top-flat nanorods deform bacterial cell envelop to inhibit their proliferation. Top-sharp nanorods (conical angle of 50°) puncture bacteria to intensely kill them. 138° is confirmed as critical top conical angle for nanorods to puncture S. aureus.
Collapse
|
6
|
Fitting pieces into the puzzle: The impact of titanium-based dental implant surface modifications on bacterial accumulation and polymicrobial infections. Adv Colloid Interface Sci 2021; 298:102551. [PMID: 34757285 DOI: 10.1016/j.cis.2021.102551] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Revised: 10/09/2021] [Accepted: 10/17/2021] [Indexed: 12/12/2022]
Abstract
Polymicrobial infection is the main cause of dental implant failure. Although numerous studies have reported the ability of titanium (Ti) surface modifications to inhibit microbial adhesion and biofilm accumulation, the majority of solutions for the utilization of Ti antibacterial surfaces have been testedin in vitro and animal models, with only a few developed surfaces progressing into clinical research. Motivated by this huge gap, we critically reviewed the scientific literature on the existing antibacterial Ti surfaces to help understand these surfaces' impact on the "puzzle" of undesirable dental implant-related infections. This manuscript comprises three main sections: (i) a narrative review on topics related to oral biofilm formation, bacterial-implant surface interactions, and on how implant-surface modifications can influence microbial accumulation; (ii) a critical evidence-based review to summarize pre-clinical and clinical studies in an attempt to "fit pieces into the puzzle" to unveil the best way to reduce microbial loads and control polymicrobial infection around dental implants showed by the current in vivo evidence; and (iii) discussion and recommendations for future research testing emerging antibacterial implant surfaces, connecting basic science and the requirements for future clinical translation. The findings of the present review suggest no consensus regarding the best available Ti surface to reduce bacterial colonization on dental implants. Smart release or on-demand activation surface coatings are a "new piece of the puzzle", which may be the most effective alternative for reducing microbial colonization on Ti surfaces, and future studies should focus on these technologies.
Collapse
|
7
|
Enhanced osteogenic differentiation of osteoblasts on CaTiO 3 nanotube film. Colloids Surf B Biointerfaces 2020; 187:110773. [PMID: 31926789 DOI: 10.1016/j.colsurfb.2020.110773] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2019] [Revised: 12/13/2019] [Accepted: 01/03/2020] [Indexed: 12/11/2022]
Abstract
Improved implant-bone interface interaction for rapid formation of strong and long-lasting bond is significantly important in orthopedic clinics. Herein, Ca-doped TiO2 nanotube film (M-CaNTs) with enhanced adhesion strength was fabricated on titanium (Ti) surface by an anodization-hydrothermal treatment. Results showed that TiO2 nanotube film (M-NTs) fabricated by modified anodization was amorphous, exhibiting 100-nm diameter and 12-nm tube wall thickness. After hydrothermal treatment, the nanotubular structure of M-CaNTs kept integrated, but was volume-expanded, exhibiting a decreased diameter (∼ 60 nm) and an increased wall thickness (∼ 30 nm). The formation of M-CaNTs proceeded preferentially at the interior surfaces of the closely aligned nanotubes, involving an in situ dissolution-recrystallization process. Though the adhesion strength of M-CaNTs was weakened by the volume-expansion derived internal stress, it was still higher than that of the traditionally obtained one. In the in vitro investigations, the combination of nanotubular structure and Ca2+ could expectedly enhance the attachment, spreading and proliferation of MC3T3-E1 cells, as well as promote the expressions of bone-specific genes, intracellular proteins and ALP activity, which in turn accelerated collagen secretion and ECM mineralization. This work provides an attractive potential for the surface modification of Ti-based implants in clinical application.
Collapse
|
8
|
Nguyen TDT, Jang YS, Kim YK, Kim SY, Lee MH, Bae TS. Osteogenesis-Related Gene Expression and Guided Bone Regeneration of a Strontium-Doped Calcium-Phosphate-Coated Titanium Mesh. ACS Biomater Sci Eng 2019; 5:6715-6724. [PMID: 33423489 DOI: 10.1021/acsbiomaterials.9b01042] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Guided bone regeneration using a perforated titanium membrane is actively used in oral and orthopedic surgeries to provide space for the subsequent filling of a new bone in the case of bone defects and to achieve proper bone augmentation and reconstruction. The surface modification of a titanium membrane using a strontium-substituted calcium phosphate coating has become a popular trend to provide better bioactivity and biocompatibility on the membrane for improving the bone regeneration because strontium can stimulate not only the differentiation of osteoblasts but also inhibit the differentiation of osteoclasts. The strontium-doped calcium phosphate coating on the titanium mesh was formed by the cyclic precalcification method, and its effects on bone regeneration were evaluated by in vitro analysis of osteogenesis-related gene expression and in vivo evaluation of osteogenesis of the titanium mesh using the rat calvarial defect model in this study. It was identified that the strontium-doped calcium phosphate-treated mesh showed a higher expression of all genes related to osteogenesis in the osteoblast cells and resulted in new bone formation with better osseointegration with the mesh in the rat calvarial defect, in comparison with the results of untreated and calcium phosphate-treated meshes.
Collapse
Affiliation(s)
- Thuy-Duong Thi Nguyen
- Faculty of Odonto-Stomatology, Hue University of Medicine and Pharmacy, Hue University, 06 Ngo Quyen Street, Hue City, Thua Thien Hue 530000, Vietnam
| | - Yong-Seok Jang
- Department of Dental Biomaterials and Institute of Biodegradable Material, Institute of Oral Bioscience, BK21 Plus Project, School of Dentistry, Jeonbuk National University, 567, Baekje-daero, Deokjin-gu, Jeonju 54896, Jeollabuk-do, South Korea
| | - Yu-Kyoung Kim
- Department of Dental Biomaterials and Institute of Biodegradable Material, Institute of Oral Bioscience, BK21 Plus Project, School of Dentistry, Jeonbuk National University, 567, Baekje-daero, Deokjin-gu, Jeonju 54896, Jeollabuk-do, South Korea
| | - Seo-Young Kim
- Department of Dental Biomaterials and Institute of Biodegradable Material, Institute of Oral Bioscience, BK21 Plus Project, School of Dentistry, Jeonbuk National University, 567, Baekje-daero, Deokjin-gu, Jeonju 54896, Jeollabuk-do, South Korea
| | - Min-Ho Lee
- Department of Dental Biomaterials and Institute of Biodegradable Material, Institute of Oral Bioscience, BK21 Plus Project, School of Dentistry, Jeonbuk National University, 567, Baekje-daero, Deokjin-gu, Jeonju 54896, Jeollabuk-do, South Korea
| | - Tae-Sung Bae
- Department of Dental Biomaterials and Institute of Biodegradable Material, Institute of Oral Bioscience, BK21 Plus Project, School of Dentistry, Jeonbuk National University, 567, Baekje-daero, Deokjin-gu, Jeonju 54896, Jeollabuk-do, South Korea
| |
Collapse
|
9
|
Hu C, Ashok D, Nisbet DR, Gautam V. Bioinspired surface modification of orthopedic implants for bone tissue engineering. Biomaterials 2019; 219:119366. [PMID: 31374482 DOI: 10.1016/j.biomaterials.2019.119366] [Citation(s) in RCA: 124] [Impact Index Per Article: 24.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2019] [Revised: 06/27/2019] [Accepted: 07/14/2019] [Indexed: 12/25/2022]
Abstract
Biomedical implants have been widely used in various orthopedic treatments, including total hip arthroplasty, joint arthrodesis, fracture fixation, non-union, dental repair, etc. The modern research and development of orthopedic implants have gradually shifted from traditional mechanical support to a bioactive graft in order to endow them with better osteoinduction and osteoconduction. Inspired by structural and mechanical properties of natural bone, this review provides a panorama of current biological surface modifications for facilitating the interaction between medical implants and bone tissue and gives a future outlook for fabricating the next-generation multifunctional and smart implants by systematically biomimicking the physiological processes involved in formation and functioning of bones.
Collapse
Affiliation(s)
- Chao Hu
- Research School of Engineering, Australian National University, ACT, 2601, Australia
| | - Deepu Ashok
- Research School of Engineering, Australian National University, ACT, 2601, Australia
| | - David R Nisbet
- Research School of Engineering, Australian National University, ACT, 2601, Australia
| | - Vini Gautam
- John Curtin School of Medical Research, Australian National University, ACT, 2601, Australia.
| |
Collapse
|
10
|
Li K, Dai F, Yan T, Xue Y, Zhang L, Han Y. Magnetic Silicium Hydroxyapatite Nanorods for Enhancing Osteoblast Response in Vitro and Biointegration in Vivo. ACS Biomater Sci Eng 2019; 5:2208-2221. [PMID: 33405773 DOI: 10.1021/acsbiomaterials.9b00073] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Osteoblast behavior playing an important role in the biointegration of the Ti implant with host bone in vivo can be regulated by surface properties and magnetic field. In order to endow the Ti surface with good osteogenesis activity, Si monosubstituted and Fe and Si cosubstituted hydroxyapatite (HAp) nanorods were fabricated on microporous TiO2 by microarc oxidation (MAO) followed with hydrothermal treatment (HT). The surface properties including microstructure, microroughness, hydrophilicity, ion release, magnetic property, cytocompatibility, and biointegration of substituted HAp nanorods were observed and evaluated, together with pure HAp nanorods and microarc oxidated (MAOed) TiO2 as controls. After being doped with Fe, MAOed TiO2 has no changes in phase composition and microroughness, whereas it displays weakly ferromagnetic behavior and can enhance osteoblast differentiation in vitro and formation of new bone in vivo, compared with the undoped one. The substituted HAp nanorods adhere firmly to TiO2 and have almost the same wettability and microroughness but additional Si, Fe, and/or Ca released into the medium, compared with pure HAp nanorods. Moreover, the cosubstituted HAp has a small ferromagnetic signal, while its saturation magnetization value is less than that of the MAOed doped with Fe. Compared to pure HA nanorods, the substituted HAp nanorods not only improve cell proliferation and differentiation in vitro, but also enhance the ability of bone integration in vivo, especially for the cosubstituted one, which should be ascribed to the combined effect of microstructure, magnetic property, and released ions.
Collapse
Affiliation(s)
- Kai Li
- State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, No. 28, Xianning West Road, Xi'an, Shaanxi 710049, P. R. China
| | - Fang Dai
- State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, No. 28, Xianning West Road, Xi'an, Shaanxi 710049, P. R. China
| | - Ting Yan
- State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, No. 28, Xianning West Road, Xi'an, Shaanxi 710049, P. R. China
| | - Yang Xue
- State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, No. 28, Xianning West Road, Xi'an, Shaanxi 710049, P. R. China
| | - Lan Zhang
- State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, No. 28, Xianning West Road, Xi'an, Shaanxi 710049, P. R. China
| | - Yong Han
- State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, No. 28, Xianning West Road, Xi'an, Shaanxi 710049, P. R. China
| |
Collapse
|
11
|
Zhou J, Li B, Han Y. F-doped TiO 2 microporous coating on titanium with enhanced antibacterial and osteogenic activities. Sci Rep 2018; 8:17858. [PMID: 30552353 PMCID: PMC6294799 DOI: 10.1038/s41598-018-35875-6] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Accepted: 11/12/2018] [Indexed: 11/21/2022] Open
Abstract
To enhance bacterial resistance and osteogenesis of titanium (Ti) -based implants, TiO2/calcium-phosphate coatings (TiCP) doped with various amounts of fluorine (F) (designated as TiCP-F1, TiCP-F6, and TiCP-F9) were prepared on Ti by micro-arc oxidation. The F doped TiCP coatings possess a microporous structure (pore size of 3-4 μm in average diameter) which is evenly covered by nano-grains of 30-60 nm in size. Successful F incorporation into TiCP was determined by X-ray photoelectron spectroscopy, and it shows weak influence on the microstructure, phase compositions, surface roughness and wettability of TiCP. All the coatings bonded firmly to the Ti substrates and showed enduring high adhesion strength in biological circumstances. The bacterial resistance and osteogenesis of the coatings were evaluated by implanting testing materials in vitro and in an infected rabbit model caused by bacteria. Both the in vitro and in vivo results indicated that TiCP and TiCP-F1 were of much higher osteogenic activity compared with Ti but lacking of bacterial resistance, whereas TiCP with high F addition (TiCP-F6 and TiCP-F9) exhibited both dramatically improved bacterial resistance and osteogenesis. In summary, TiCP-F6 possessed the best antibacterial and osteogenic activities, especially exhibited excellent osseointegration efficacy in the infected rabbit model.
Collapse
Affiliation(s)
- Jianhong Zhou
- Institute of Physics & Optoelectronics Technology, Baoji University of Arts and Sciences, Baoji, 721016, China
- State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, Xi'an, 710049, China
| | - Bo Li
- State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, Xi'an, 710049, China
| | - Yong Han
- State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, Xi'an, 710049, China.
| |
Collapse
|
12
|
Nanorod diameter modulated osteogenic activity of hierarchical micropore/nanorod-patterned coatings via a Wnt/β-catenin pathway. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE 2018; 14:1719-1731. [DOI: 10.1016/j.nano.2018.04.006] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2017] [Revised: 03/27/2018] [Accepted: 04/09/2018] [Indexed: 01/16/2023]
|
13
|
Lin J, Chen X, Chen C, Hu J, Zhou C, Cai X, Wang W, Zheng C, Zhang P, Cheng J, Guo Z, Liu H. Durably Antibacterial and Bacterially Antiadhesive Cotton Fabrics Coated by Cationic Fluorinated Polymers. ACS APPLIED MATERIALS & INTERFACES 2018; 10:6124-6136. [PMID: 29356496 DOI: 10.1021/acsami.7b16235] [Citation(s) in RCA: 187] [Impact Index Per Article: 31.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Considerable attention has been devoted to producing antibacterial fabrics due to their very wide applications in medicine, hygiene, hospital, etc. However, the poor antibacterial durability and bad bacterial antiadhesion capacity of most existing antibacterial fabrics limit their applications. In this work, a series of antibacterial and polymeric quaternary ammonium monomers with different alkyl chain length were successfully synthesized to copolymerize with fluorine-containing and other acrylic monomers to generate cationic fluorinated polymer emulsions and durably antibacterial and bacterially antiadhesive cotton fabrics. The relation between antibacterial constituent and its antibacterial activity was investigated. The study indicated that the alkyl chain length and contents of the antibacterial monomers, as well as the add-on percentage of polymer greatly influenced the antibacterial activities of the fabrics. In addition, it was found that incorporation of fluorine component into the polymer greatly enhanced the antibacterial activity and bacterial antiadhesion of the treated fabrics due to the low surface energy induced hydrophobicity. Finally, antibacterial and antiadhesive models of action of the obtained fabrics were illustrated.
Collapse
Affiliation(s)
- Jing Lin
- School of Chemistry and Chemical Engineering, Guangzhou University , Guangzhou 510006, P. R. China
| | - XiaoYu Chen
- School of Chemistry and Chemical Engineering, Guangzhou University , Guangzhou 510006, P. R. China
| | - ChunYan Chen
- School of Chemistry and Chemical Engineering, Guangzhou University , Guangzhou 510006, P. R. China
| | - JieTao Hu
- School of Chemistry and Chemical Engineering, Guangzhou University , Guangzhou 510006, P. R. China
| | - CaiLong Zhou
- School of Chemistry and Chemical Engineering, South China University of Technology , Guangzhou 510640, P. R. China
| | - XianFang Cai
- School of Chemistry and Chemical Engineering, Guangzhou University , Guangzhou 510006, P. R. China
| | - Wei Wang
- School of Chemistry and Chemical Engineering, Guangzhou University , Guangzhou 510006, P. R. China
| | - Cheng Zheng
- School of Chemistry and Chemical Engineering, Guangzhou University , Guangzhou 510006, P. R. China
| | - PeiPei Zhang
- Department of Bioengineering, University of Maryland at College Park , College Park, Maryland 20742, United States
| | - Jiang Cheng
- School of Chemistry and Chemical Engineering, South China University of Technology , Guangzhou 510640, P. R. China
| | - ZhanHu Guo
- Integrated Composites Laboratory (ICL), Department of Chemical and Biomolecular Engineering, University of Tennessee , Knoxville, Tennessee 37996, United States
| | - Hu Liu
- National Engineering Research Center for Advanced Polymer Processing Technology, Zhengzhou University , Zhengzhou, Henan 450002, P. R. China
| |
Collapse
|
14
|
Tsiapalis D, De Pieri A, Biggs M, Pandit A, Zeugolis DI. Biomimetic Bioactive Biomaterials: The Next Generation of Implantable Devices. ACS Biomater Sci Eng 2017; 3:1172-1174. [PMID: 33440507 DOI: 10.1021/acsbiomaterials.7b00372] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
| | - Andrea De Pieri
- National University of Ireland Galway and Proxy Biomedical Ltd
| | | | | | | |
Collapse
|
15
|
Wang L, Wang M, Wang Y, Shao Y, Zhu Y. Facile synthesis and the phase transition mechanism of fluoridated hydroxyapatite with a hierarchical architecture. CrystEngComm 2017. [DOI: 10.1039/c7ce01871a] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The crystal growth process of FHA is investigated. The crystal orientation relationship is found to be [010]FHA//[001]DCPA and (001)FHA//(010)DCPA.
Collapse
Affiliation(s)
- Liping Wang
- Key Laboratory of Inorganic Coating Materials CAS
- Shanghai Institute of Ceramics
- Chinese Academy of Sciences
- Shanghai 200050
- China
| | - Ming Wang
- Key Laboratory of Inorganic Coating Materials CAS
- Shanghai Institute of Ceramics
- Chinese Academy of Sciences
- Shanghai 200050
- China
| | - Yunli Wang
- Key Laboratory of Inorganic Coating Materials CAS
- Shanghai Institute of Ceramics
- Chinese Academy of Sciences
- Shanghai 200050
- China
| | - Yiran Shao
- Key Laboratory of Inorganic Coating Materials CAS
- Shanghai Institute of Ceramics
- Chinese Academy of Sciences
- Shanghai 200050
- China
| | - Yingchun Zhu
- Key Laboratory of Inorganic Coating Materials CAS
- Shanghai Institute of Ceramics
- Chinese Academy of Sciences
- Shanghai 200050
- China
| |
Collapse
|