1
|
Jayamaha G, Maleki M, Bentley CL, Kang M. Practical guidelines for the use of scanning electrochemical cell microscopy (SECCM). Analyst 2024; 149:2542-2555. [PMID: 38632960 DOI: 10.1039/d4an00117f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/19/2024]
Abstract
Scanning electrochemical cell microscopy (SECCM) has emerged as a transformative technology for electrochemical materials characterisation and the study of single entities, garnering global adoption by numerous research groups. While details on the instrumentation and operational principles of SECCM are readily available, the growing need for practical guidelines, troubleshooting strategies, and a systematic overview of applications and trends has become increasingly evident. This tutorial review addresses this gap by offering a comprehensive guide to the practical application of SECCM. The review begins with a discussion of recent developments and trends in the application of SECCM, before providing systematic approaches to (and the associated troubleshooting associated with) instrumental set up, probe fabrication, substrate preparation and the deployment of environmental (e.g., atmosphere and humidity) control. Serving as an invaluable resource, this tutorial review aims to equip researchers and practitioners entering the field with a comprehensive guide to essential considerations for conducting successful SECCM experiments.
Collapse
Affiliation(s)
- Gunani Jayamaha
- School of Chemistry, The University of Sydney, Camperdown, 2006 NSW, Australia.
| | - Mahin Maleki
- Institute for Frontier Materials, Deakin University, Burwood, VIC 3125, Australia
| | - Cameron L Bentley
- School of Chemistry, Monash University, Clayton, 3800 VIC, Australia
| | - Minkyung Kang
- School of Chemistry, The University of Sydney, Camperdown, 2006 NSW, Australia.
| |
Collapse
|
2
|
Zhao Y, Lin L, Liu R, Liu Y, Wang Y, Wang D. Dynamic and Asymmetrical Ion Concentration Polarization in Dual Nanopipettes. Anal Chem 2024; 96:4190-4196. [PMID: 38411587 DOI: 10.1021/acs.analchem.3c05343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
Dual nanopipettes with two channels have been receiving great attention due to the convenient experimental setup and multiple measuring channels in sensing applications at nanoscale, while the involved dynamic and asymmetrical ion transport processes have not been fully elucidated. In this paper, both experimental and simulation methods are used to investigate the dynamic mass transport processes inside dual nanopipettes with two well-separated channels. The results present that the ion transport resistance through the two channels (R12) is always the add-up of the individual ones (R13 + R23) with respect to the bulk solutions, at various ionic strengths and scan rates. A constant zero-current potential is obtained when loading an asymmetrical electrolyte concentration in the two channels, and the zero-potential current displays a good linear relationship with the bulk concentration outside the pipet. Besides revealing the dynamic and asymmetrical concentration polarization in the dual nanopipettes, these results would also further promote the better usage of dual nanopipettes in electrochemical sensing and imaging applications.
Collapse
Affiliation(s)
- Yingjie Zhao
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Lan Lin
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Rujia Liu
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Yun Liu
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Yue Wang
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Dengchao Wang
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing 100049, P. R. China
- Binzhou Institute of Technology, Weiqiao-UCAS Science and Technology Park, Binzhou 256606, Shandong Province, P. R. China
| |
Collapse
|
3
|
Ando S, Yamamoto E, Kobayashi M, Kumatani A, Osada M. Facile Synthesis of Pd Nanosheets and Implications for Superior Catalytic Activity. ACS NANO 2024; 18:461-469. [PMID: 37929939 DOI: 10.1021/acsnano.3c07861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2023]
Abstract
As a member of the 2D materials family, 2D metal nanosheets (metallenes) have received increasing attention due to their intriguing properties distinct from those of graphene and other inorganic 2D nanosheets. However, the synthesis of metallenes is still challenging, owing to the lack of an efficient synthetic approach. Here we present a facile one-pot approach to the controlled synthesis of Pd nanosheets. A key feature of this process is a stepwise reaction using 2,4,6-trichlorophenyl formate (TCPF); TCPF emits carbon monoxide gas, which acts as both a reductant and a surface capping agent, promoting the anisotropic 2D growth of the Pd nanosheets. Photoemission spectroscopy revealed some peculiar features of the surface charge and valence band states due to suppressed electron transfer at the 2D surface. This surface state caused improved catalytic activity for the hydrogen evolution reaction compared to that of bulk Pd.
Collapse
Affiliation(s)
- Sumiya Ando
- Department of Materials Chemistry & Institute of Materials and Systems for Sustainability (IMaSS), Nagoya University, Nagoya 464-8601, Japan
| | - Eisuke Yamamoto
- Department of Materials Chemistry & Institute of Materials and Systems for Sustainability (IMaSS), Nagoya University, Nagoya 464-8601, Japan
| | - Makoto Kobayashi
- Department of Materials Chemistry & Institute of Materials and Systems for Sustainability (IMaSS), Nagoya University, Nagoya 464-8601, Japan
| | - Akichika Kumatani
- Institute of Engineering Innovation (IEI), School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan
- Precursory Research for Embryonic Science and Technology (PRESTO), Japan Science and Technology Agency (JST), Saitama 332-0012, Japan
- WPI-Advanced Institute for Materials Research (AIMR) & Graduate School of Environmental Studies, Tohoku University, Sendai 980-8577, Japan
| | - Minoru Osada
- Department of Materials Chemistry & Institute of Materials and Systems for Sustainability (IMaSS), Nagoya University, Nagoya 464-8601, Japan
- Research Center for Crystalline Materials Engineering, Nagoya University, Nagoya 464-8601, Japan
| |
Collapse
|
4
|
Zheng Q, Zhuang J, Wang T, Liao X, Cheng L, Gu S. Investigating the effects of solution viscosity on the stability and success rate of SECCM imaging. Ultramicroscopy 2023; 254:113843. [PMID: 37683562 DOI: 10.1016/j.ultramic.2023.113843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 08/21/2023] [Accepted: 08/31/2023] [Indexed: 09/10/2023]
Abstract
Due to the capability of simultaneously detecting the morphology and electrochemical information of samples and limiting the electrochemical reaction to a range approximately the size of the inner diameter of the pipette tip opening, scanning electrochemical cell microscopy (SECCM) enables higher precision local electrochemical measurement and surface material delivery and has been demonstrating unique advantages and broad application prospects. However, the meniscus droplet at the pipette tip of SECCM is equivalent to the opening radius of the pipette tip, which is usually tens of nanometers to hundreds of nanometers. The tiny meniscus droplet makes it susceptible to evaporation and crystallization, which increases the likelihood of the pipette colliding with the sample during the scanning process, resulting in the failure of scanning. In this paper, the influence of solution viscosity on the shape variation of the droplet at the tip during the movement of the pipette of SECCM was studied by finite element analysis. It is proved that the increase of solution viscosity is helpful in reducing the shape variation of the droplet at the tip during the movement of the pipette. Then scanning experiments were carried out using a flat Au substrate and Au substrates with rounded triangle and rounded rectangular convex structures as the samples. According to the experimental results, increasing solution viscosity improves scanning success rates and scanning quality and effectively lowers the MSE of the scanning results. The experimental results also show that SECCM can image at a higher speed when the solution's viscosity increases since the deformation of the droplet at the tip is less than with a typical solution.
Collapse
Affiliation(s)
- Qiangqiang Zheng
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, PR China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Jian Zhuang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, PR China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, PR China.
| | - Tianying Wang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, PR China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Xiaobo Liao
- Key Laboratory of Testing Technology for Manufacturing Process, Ministry of Education, Southwest University of Science and Technology, Mianyang 621010, PR China
| | - Lei Cheng
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, PR China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Shengbo Gu
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, PR China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, PR China
| |
Collapse
|
5
|
Checa M, Fuhr AS, Sun C, Vasudevan R, Ziatdinov M, Ivanov I, Yun SJ, Xiao K, Sehirlioglu A, Kim Y, Sharma P, Kelley KP, Domingo N, Jesse S, Collins L. High-speed mapping of surface charge dynamics using sparse scanning Kelvin probe force microscopy. Nat Commun 2023; 14:7196. [PMID: 37938577 PMCID: PMC10632481 DOI: 10.1038/s41467-023-42583-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Accepted: 10/15/2023] [Indexed: 11/09/2023] Open
Abstract
Unraveling local dynamic charge processes is vital for progress in diverse fields, from microelectronics to energy storage. This relies on the ability to map charge carrier motion across multiple length- and timescales and understanding how these processes interact with the inherent material heterogeneities. Towards addressing this challenge, we introduce high-speed sparse scanning Kelvin probe force microscopy, which combines sparse scanning and image reconstruction. This approach is shown to enable sub-second imaging (>3 frames per second) of nanoscale charge dynamics, representing several orders of magnitude improvement over traditional Kelvin probe force microscopy imaging rates. Bridging this improved spatiotemporal resolution with macroscale device measurements, we successfully visualize electrochemically mediated diffusion of mobile surface ions on a LaAlO3/SrTiO3 planar device. Such processes are known to impact band-alignment and charge-transfer dynamics at these heterointerfaces. Furthermore, we monitor the diffusion of oxygen vacancies at the single grain level in polycrystalline TiO2. Through temperature-dependent measurements, we identify a charge diffusion activation energy of 0.18 eV, in good agreement with previously reported values and confirmed by DFT calculations. Together, these findings highlight the effectiveness and versatility of our method in understanding ionic charge carrier motion in microelectronics or nanoscale material systems.
Collapse
Affiliation(s)
- Marti Checa
- Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, TN, 37831, USA.
| | - Addis S Fuhr
- Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, TN, 37831, USA
| | - Changhyo Sun
- School of Advanced Materials Science and Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Rama Vasudevan
- Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, TN, 37831, USA
| | - Maxim Ziatdinov
- Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, TN, 37831, USA
- Computational Sciences and Engineering Division, Oak Ridge National Laboratory, Oak Ridge, TN, 37923, USA
| | - Ilia Ivanov
- Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, TN, 37831, USA
| | - Seok Joon Yun
- Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, TN, 37831, USA
- Department of Semiconductor, University of Ulsan, Ulsan, 44610, Korea
| | - Kai Xiao
- Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, TN, 37831, USA
| | - Alp Sehirlioglu
- Department of Materials Science and Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Yunseok Kim
- School of Advanced Materials Science and Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Pankaj Sharma
- College of Science and Engineering, Flinders University, Bedford Park, SA, 5042, Australia
- ARC Centre of Excellence in Future Low-Energy Electronics Technologies (FLEET), UNSW Sydney, Sydney, NSW, 2052, Australia
| | - Kyle P Kelley
- Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, TN, 37831, USA
| | - Neus Domingo
- Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, TN, 37831, USA
| | - Stephen Jesse
- Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, TN, 37831, USA
| | - Liam Collins
- Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, TN, 37831, USA.
| |
Collapse
|
6
|
Lai Z, Liu M, Bi P, Huang F, Jin Y. Perspectives on Corrosion Studies Using Scanning Electrochemical Cell Microscopy: Challenges and Opportunities. Anal Chem 2023; 95:15833-15850. [PMID: 37844123 DOI: 10.1021/acs.analchem.3c02423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2023]
Abstract
Scanning electrochemical cell microscopy (SECCM) allows for electrochemical imaging at the micro- or nanoscale by confining the electrochemical reaction cell in a small meniscus formed at the end of a micro- or nanopipette. This technique has gained popularity in electrochemical imaging due to its high-throughput nature. Although it shows considerable application potential in corrosion science, there are still formidable and exciting challenges to be faced, particularly relating to the high-throughput characterization and analysis of microelectrochemical big data. The objective of this perspective is to arouse attention and provide opinions on the challenges, recent progress, and future prospects of the SECCM technique to the electrochemical society, particularly from the viewpoint of corrosion scientists. Specifically, four main topics are systematically reviewed and discussed: (1) the development of SECCM; (2) the applications of SECCM for corrosion studies; (3) the challenges of SECCM in corrosion studies; and (4) the opportunities of SECCM for corrosion science.
Collapse
Affiliation(s)
- Zhaogui Lai
- National Center for Materials Service Safety, University of Science and Technology Beijing, Beijing 102206, P. R. China
| | - Min Liu
- New Materials Institute, University of Nottingham Ningbo China, Ningbo 315100, P. R. China
| | - Peng Bi
- Laboratory for Nuclear Materials, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland
| | - Feifei Huang
- National Center for Materials Service Safety, University of Science and Technology Beijing, Beijing 102206, P. R. China
| | - Ying Jin
- National Center for Materials Service Safety, University of Science and Technology Beijing, Beijing 102206, P. R. China
| |
Collapse
|
7
|
Jin R, Zhou W, Xu Y, Jiang D, Fang D. Electrochemical Visualization of Membrane Proteins in Single Cells at a Nanoscale Using Scanning Electrochemical Cell Microscopy. Anal Chem 2023. [PMID: 37358933 DOI: 10.1021/acs.analchem.3c00114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/28/2023]
Abstract
The electrochemical visualization of proteins in the plasma membrane of single fixed cells was achieved with a spatial resolution of 160 nm using scanning electrochemical cell microscopy. The model protein, the carcinoembryonic antigen (CEA), is linked with a ruthenium complex (Ru(bpy)32+)-tagged antibody, which exhibits redox peaks in its cyclic voltammetry curves after a nanopipette tip contacts the cellular membrane. Based on the potential-resolved oxidation or reduction currents, an uneven distribution of membrane CEAs on the cells is electrochemically visualized, which could only be achieved previously using super-resolution optical microscopy. Compared with current electrochemical microscopy, the single-cell scanning electrochemical cell microscopy (SECCM) strategy not only improves the spatial resolution but also utilizes the potential-resolved current from the antibody-antigen complex to increase electrochemical imaging accuracy. Eventually, the electrochemical visualization of cellular proteins at the nanoscale enables the super-resolution study of cells to provide more biological information.
Collapse
Affiliation(s)
- Rong Jin
- School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu 211126, China
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
| | - Wenting Zhou
- School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu 211126, China
| | - Yanyan Xu
- School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu 211126, China
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
| | - Dechen Jiang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
| | - Danjun Fang
- School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu 211126, China
| |
Collapse
|
8
|
Godeffroy L, Makogon A, Gam Derouich S, Kanoufi F, Shkirskiy V. Imaging and Quantifying the Chemical Communication between Single Particles in Metal Alloys. Anal Chem 2023. [PMID: 37327768 DOI: 10.1021/acs.analchem.3c01258] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The communication within particle agglomerates in industrial alloys can have a significant impact on the macroscopic reactivity, putting a high demand on the adaptation of wide-field methodologies to clarify this phenomenon. In this work, we report the application of correlated optical microscopies probing operando both local pH and local surface chemical transformation correlated with identical location scanning electron microscopy to quantify in situ the structure reactivity of particle agglomerates of foreign elements in the Al alloy. The optical operando analyses allow us (i) to reveal and quantify the local production of OH- from proton and oxygen reduction at individual Si- or Fe-rich microparticles and (ii) to quantify (and model) the chemical communication between these active sites, within a few micrometer range, on the local chemical transformation of the material. Wide-field image analysis highlights the statistical importance of chemical communication that may introduce a new conceptual framework for the understanding of the mechanisms in related fields of charge transfer, electrocatalysis, and corrosion.
Collapse
|
9
|
Hengsteler J, Kanes KA, Khasanova L, Momotenko D. Beginner's Guide to Micro- and Nanoscale Electrochemical Additive Manufacturing. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2023; 16:71-91. [PMID: 37068744 DOI: 10.1146/annurev-anchem-091522-122334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Electrochemical additive manufacturing is an advanced microfabrication technology capable of producing features of almost unlimited geometrical complexity. A unique combination of the capacity to process conductive materials, design freedom, and micro- to nanoscale resolution offered by these electrochemical techniques promises tremendous opportunities for a multitude of future applications spanning microelectronics, sensing, robotics, and energy storage. This review aims to equip readers with the basic principles of electrochemical 3D printing at the small length scale. By describing the basic principles of electrochemical additive manufacturing technology and using the recent advances in the field, this beginner's guide illustrates how controlling the fundamental phenomena that underpin the print process can be used to vary dimensions, morphology, and microstructure of printed structures.
Collapse
Affiliation(s)
- Julian Hengsteler
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Zurich, Switzerland
| | - Karuna Aurel Kanes
- Department of Chemistry, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany;
| | - Liaisan Khasanova
- Department of Chemistry, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany;
| | - Dmitry Momotenko
- Department of Chemistry, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany;
| |
Collapse
|
10
|
Anderson KL, Edwards MA. Evaluating Analytical Expressions for Scanning Electrochemical Cell Microscopy (SECCM). Anal Chem 2023; 95:8258-8266. [PMID: 37191580 DOI: 10.1021/acs.analchem.3c00216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Scanning electrochemical cell microscopy (SECCM) maps the electrochemical activity of a surface with nanoscale resolution using an electrolyte-filled nanopipette. The meniscus at the end of the pipet is sequentially placed at an array of locations across the surface, forming a series of nanometric electrochemical cells where the current-voltage response is measured. Quantitative interpretation of these responses typically employs numerical modeling to solve the coupled equations of transport and electron transfer, which require costly software or self-written code. Expertise and time are required to build and solve numerical models, which must be rerun for each new experiment. In contrast, algebraic expressions directly relate the current response to physical parameters. They are simpler to use, faster to calculate, and can provide greater insight but frequently require simplifying assumptions. In this work, we provide algebraic expressions for current and concentration distributions in SECCM experiments, which are formulated by approximating the pipet and meniscus using 1-D spherical coordinates. Expressions for the current and concentration distributions as a function of experimental parameters and in various conditions (steady state and time dependent, diffusion limited, and including migration) all show excellent agreement with numerical simulations employing a full geometry. Uses of the analytical expressions include determination of expected currents in experiments and quantifying electron-transfer rate constants in SECCM experiments.
Collapse
Affiliation(s)
- Kamsy Lerae Anderson
- Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, Arkansas 72701, United States
| | - Martin Andrew Edwards
- Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, Arkansas 72701, United States
| |
Collapse
|
11
|
Santana Santos C, Jaato BN, Sanjuán I, Schuhmann W, Andronescu C. Operando Scanning Electrochemical Probe Microscopy during Electrocatalysis. Chem Rev 2023; 123:4972-5019. [PMID: 36972701 PMCID: PMC10168669 DOI: 10.1021/acs.chemrev.2c00766] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023]
Abstract
Scanning electrochemical probe microscopy (SEPM) techniques can disclose the local electrochemical reactivity of interfaces in single-entity and sub-entity studies. Operando SEPM measurements consist of using a SEPM tip to investigate the performance of electrocatalysts, while the reactivity of the interface is simultaneously modulated. This powerful combination can correlate electrochemical activity with changes in surface properties, e.g., topography and structure, as well as provide insight into reaction mechanisms. The focus of this review is to reveal the recent progress in local SEPM measurements of the catalytic activity of a surface toward the reduction and evolution of O2 and H2 and electrochemical conversion of CO2. The capabilities of SEPMs are showcased, and the possibility of coupling other techniques to SEPMs is presented. Emphasis is given to scanning electrochemical microscopy (SECM), scanning ion conductance microscopy (SICM), electrochemical scanning tunneling microscopy (EC-STM), and scanning electrochemical cell microscopy (SECCM).
Collapse
Affiliation(s)
- Carla Santana Santos
- Analytical Chemistry - Center for Electrochemical Sciences (CES), Faculty of Chemistry and Biochemistry, Ruhr University Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Bright Nsolebna Jaato
- Technical Chemistry III, Center for Nanointegration Duisburg-Essen (CENIDE), University of Duisburg-Essen Carl-Benz-Straße 199, 47057 Duisburg, Germany
| | - Ignacio Sanjuán
- Technical Chemistry III, Center for Nanointegration Duisburg-Essen (CENIDE), University of Duisburg-Essen Carl-Benz-Straße 199, 47057 Duisburg, Germany
| | - Wolfgang Schuhmann
- Analytical Chemistry - Center for Electrochemical Sciences (CES), Faculty of Chemistry and Biochemistry, Ruhr University Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Corina Andronescu
- Technical Chemistry III, Center for Nanointegration Duisburg-Essen (CENIDE), University of Duisburg-Essen Carl-Benz-Straße 199, 47057 Duisburg, Germany
| |
Collapse
|
12
|
Wang Y, Li M, Ren H. Voltammetric Mapping of Hydrogen Evolution Reaction on Pt Locally via Scanning Electrochemical Cell Microscopy. ACS MEASUREMENT SCIENCE AU 2022; 2:304-308. [PMID: 36785572 PMCID: PMC9836041 DOI: 10.1021/acsmeasuresciau.2c00012] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The advancement in nanoscale electrochemical tools has offered the opportunity to better understand heterogeneity at electrochemical interfaces. Scanning electrochemical cell microscopy (SECCM) has been increasingly used for revealing local kinetics and the distribution of active sites in electrocatalysis. Constant-contact scanning and hopping scanning are the two commonly used modes. The former is intrinsically faster, whereas the latter enables full voltammetry at individual locations. Herein, we revisit a less used mode that combines the advantages of hopping and constant-contact scan, resulting in a faster voltammetric mapping. In this mode, the nanodroplet cell in SECCM maintains contact with the surface during the scanning and makes intermittent pauses for local voltammetry. The elimination of frequent retraction and approach greatly increases the speed of mapping. In addition, iR correction can be readily applied to the voltammetry, resulting in more accurate measurements of the electrode kinetics. This scanning mode is demonstrated in the oxidation of a ferrocene derivative on HOPG and hydrogen evolution reaction (HER) on polycrystalline Pt, serving as model systems for outer-sphere and inner-sphere electron transfer reactions, respectively. While the kinetics of the inner-sphere reaction is consistent spatially, heterogeneity is observed for the kinetics of HER, which is correlated with the crystal orientation of Pt.
Collapse
|
13
|
Swinya D, Martín-Yerga D, Walker M, Unwin PR. Surface Nanostructure Effects on Dopamine Adsorption and Electrochemistry on Glassy Carbon Electrodes. THE JOURNAL OF PHYSICAL CHEMISTRY. C, NANOMATERIALS AND INTERFACES 2022; 126:13399-13408. [PMID: 35983313 PMCID: PMC9377355 DOI: 10.1021/acs.jpcc.2c02801] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 07/12/2022] [Indexed: 06/15/2023]
Abstract
Dopamine (DA) adsorption and electron-transfer kinetics are strongly sensitive to the structure and composition of carbon electrodes. Activation of carbon surfaces is a popular method to improve DA detection, but the role of carbon structural features on DA behavior remains uncertain. Herein, we use scanning electrochemical cell microscopy (SECCM) for local anodization of glassy carbon (GC) electrodes in acid media followed by electrochemical imaging of DA adsorption and electrochemistry covering both unmodified and anodized GC regions of the same electrode. Electrochemical measurements of adsorbed DA involve the delivery of DA from the SECCM meniscus (30 μM) for 1 s periods followed by voltammetric analysis at a reasonable sweep rate (47 V s-1). This general approach reduces effects from interelectrode variability and allows for considerable numbers of measurements and statistical analysis of electrochemical data sets. Localized electrode activity is correlated to surface structure and chemistry by a range of characterization techniques. Anodization enhances DA electron-transfer kinetics and provides more sites for adsorption (higher specific surface area). A consequence is that adsorption takes longer to approach completion on the anodized surface. In fact, normalizing DA surface coverage by the electrochemical surface area (ECSA) reveals that adsorption is less extensive on anodized surfaces compared to as-prepared GC on the same time scale. Thus, ECSA, which has often been overlooked when calculating DA surface coverage on carbon electrodes, even where different activation methods would be expected to result in different surface roughness and nanostructure, is an important consideration. Lower graphitic and higher oxygen content on anodized GC also suggest that oxygen-containing functional groups do not necessarily enhance DA adsorption and may have the opposite effect. This work further demonstrates SECCM as a powerful technique for revealing surface structure-function relationships and correlations at heterogeneous electrodes.
Collapse
Affiliation(s)
- Dalia
L. Swinya
- Department
of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Daniel Martín-Yerga
- Department
of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Marc Walker
- Department
of Physics, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Patrick R. Unwin
- Department
of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| |
Collapse
|
14
|
Chen Q, Zhao J, Deng X, Shan Y, Peng Y. Single-Entity Electrochemistry of Nano- and Microbubbles in Electrolytic Gas Evolution. J Phys Chem Lett 2022; 13:6153-6163. [PMID: 35762985 DOI: 10.1021/acs.jpclett.2c01388] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Gas bubbles are found in diverse electrochemical processes, ranging from electrolytic water splitting to chlor-alkali electrolysis, as well as photoelectrochemical processes. Understanding the intricate influence of bubble evolution on the electrode processes and mass transport is key to the rational design of efficient devices for electrolytic energy conversion and thus requires precise measurement and analysis of individual gas bubbles. In this Perspective, we review the latest advances in single-entity measurement of gas bubbles on electrodes, covering the approaches of voltammetric and galvanostatic studies based on nanoelectrodes, probing bubble evolution using scanning probe electrochemistry with spatial information, and monitoring the transient nature of nanobubble formation and dynamics with opto-electrochemical imaging. We emphasize the intrinsic and quantitative physicochemical interpretation of single gas bubbles from electrochemical data, highlighting the fundamental understanding of the heterogeneous nucleation, dynamic state of the three-phase boundary, and the correlation between electrolytic bubble dynamics and nanocatalyst activities. In addition, a brief discussion of future perspectives is presented.
Collapse
Affiliation(s)
- Qianjin Chen
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, China
| | - Jiao Zhao
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, China
| | - Xiaoli Deng
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, China
| | - Yun Shan
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, China
| | - Yu Peng
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, China
| |
Collapse
|
15
|
Yang Z, Gura L, Kalaß F, Marschalik P, Brinker M, Kirstaedter W, Hartmann J, Thielsch G, Junkes H, Heyde M, Freund HJ. A high-speed variable-temperature ultrahigh vacuum scanning tunneling microscope with spiral scan capabilities. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:053704. [PMID: 35649753 DOI: 10.1063/5.0079868] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Accepted: 04/08/2022] [Indexed: 06/15/2023]
Abstract
We present the design and development of a variable-temperature high-speed scanning tunneling microscope (STM). The setup consists of a two-chamber ultra-high vacuum system, including a preparation and a main chamber. The preparation chamber is equipped with standard preparation tools for sample cleaning and film growth. The main chamber hosts the STM that is located within a continuous flow cryostat for counter-cooling during high-temperature measurements. The microscope body is compact, rigid, and highly symmetric to ensure vibrational stability and low thermal drift. We designed a hybrid scanner made of two independent tube piezos for slow and fast scanning, respectively. A commercial STM controller is used for slow scanning, while a high-speed Versa Module Eurocard bus system controls fast scanning. Here, we implement non-conventional spiral geometries for high-speed scanning, which consist of smooth sine and cosine signals created by an arbitrary waveform generator. The tip scans in a quasi-constant height mode, where the logarithm of the tunneling current signal can be regarded as roughly proportional to the surface topography. Scan control and data acquisition have been programmed in the experimental physics and industrial control system framework. With the spiral scans, we atomically resolved diffusion processes of oxygen atoms on the Ru(0001) surface and achieved a time resolution of 8.3 ms per frame at different temperatures. Variable-temperature measurements reveal an influence of the temperature on the oxygen diffusion rate.
Collapse
Affiliation(s)
- Zechao Yang
- Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, 14195 Berlin, Germany
| | - Leonard Gura
- Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, 14195 Berlin, Germany
| | - Florian Kalaß
- Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, 14195 Berlin, Germany
| | - Patrik Marschalik
- Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, 14195 Berlin, Germany
| | - Matthias Brinker
- Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, 14195 Berlin, Germany
| | - William Kirstaedter
- Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, 14195 Berlin, Germany
| | - Jens Hartmann
- Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, 14195 Berlin, Germany
| | - Gero Thielsch
- Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, 14195 Berlin, Germany
| | - Heinz Junkes
- Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, 14195 Berlin, Germany
| | - Markus Heyde
- Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, 14195 Berlin, Germany
| | - Hans-Joachim Freund
- Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, 14195 Berlin, Germany
| |
Collapse
|
16
|
Liu G, Hao L, Li H, Zhang K, Yu X, Li D, Zhu X, Hao D, Ma Y, Ma L. Topography Mapping with Scanning Electrochemical Cell Microscopy. Anal Chem 2022; 94:5248-5254. [PMID: 35312291 DOI: 10.1021/acs.analchem.1c04692] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
High-resolution scanning electrochemical cell microscopy (SECCM), synchronously visualizing the topography and electrochemical activity, could be used to directly correlate the structure and activity of materials nanoscopically. However, its topographical measurement is largely restricted by the size and stability of the meniscus droplet formed at the end of the nanopipette. In this paper, we report a scheme that could reliably gain several tens nanometer resolution (≥65 nm) of SECCM using homemade ∼50 nm inner diameter probes. Furthermore, the topography and hydrogen evolution reaction (HER) activity of ∼45 nm self-assembled Au nanoparticles monolayer were simultaneously recorded successfully. This scheme could make mapping of both topologic and chemical properties of samples in the nanometer regime with SECCM routinely, which potentially can largely expand the field of SECCM applications.
Collapse
Affiliation(s)
- Gen Liu
- Tianjin International Center for Nanoparticles and Nanosystems, Tianjin University, Tianjin 300072, P. R. China
| | - Luzhen Hao
- Tianjin International Center for Nanoparticles and Nanosystems, Tianjin University, Tianjin 300072, P. R. China
| | - Hao Li
- Tianjin International Center for Nanoparticles and Nanosystems, Tianjin University, Tianjin 300072, P. R. China
| | - Kaimin Zhang
- Tianjin International Center for Nanoparticles and Nanosystems, Tianjin University, Tianjin 300072, P. R. China
| | - Xue Yu
- Tianjin International Center for Nanoparticles and Nanosystems, Tianjin University, Tianjin 300072, P. R. China
| | - Dong Li
- Tianjin International Center for Nanoparticles and Nanosystems, Tianjin University, Tianjin 300072, P. R. China
| | - Xiaodong Zhu
- Tianjin International Center for Nanoparticles and Nanosystems, Tianjin University, Tianjin 300072, P. R. China
| | - Danni Hao
- Tianjin International Center for Nanoparticles and Nanosystems, Tianjin University, Tianjin 300072, P. R. China
| | - Yanqing Ma
- Tianjin International Center for Nanoparticles and Nanosystems, Tianjin University, Tianjin 300072, P. R. China.,State Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, P. R. China
| | - Lei Ma
- Tianjin International Center for Nanoparticles and Nanosystems, Tianjin University, Tianjin 300072, P. R. China
| |
Collapse
|
17
|
Guo SX, Bentley CL, Kang M, Bond AM, Unwin PR, Zhang J. Advanced Spatiotemporal Voltammetric Techniques for Kinetic Analysis and Active Site Determination in the Electrochemical Reduction of CO 2. Acc Chem Res 2022; 55:241-251. [PMID: 35020363 DOI: 10.1021/acs.accounts.1c00617] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
ConspectusElectrochemical reduction of the greenhouse gas CO2 offers prospects for the sustainable generation of fuels and industrially useful chemicals when powered by renewable electricity. However, this electrochemical process requires the use of highly stable, selective, and active catalysts. The development of such catalysts should be based on a detailed kinetic and mechanistic understanding of the electrochemical CO2 reduction reaction (eCO2RR), ideally through the resolution of active catalytic sites in both time (i.e., temporally) and space (i.e., spatially). In this Account, we highlight two advanced spatiotemporal voltammetric techniques for electrocatalytic studies and describe the considerable insights they provide on the eCO2RR. First, Fourier transformed large-amplitude alternating current voltammetry (FT ac voltammetry), as applied by the Monash Electrochemistry Group, enables the resolution of rapid underlying electron-transfer processes in complex reactions, free from competing processes, such as the background double-layer charging current, slow catalytic reactions, and solvent/electrolyte electrolysis, which often mask conventional voltammetric measurements of the eCO2RR. Crucially, FT ac voltammetry allows details of the catalytically active sites or the rate-determining step to be revealed under catalytic turnover conditions. This is well illustrated in investigations of the eCO2RR catalyzed by Bi where formate is the main product. Second, developments in scanning electrochemical cell microscopy (SECCM) by the Warwick Electrochemistry and Interfaces Group provide powerful methods for obtaining high-resolution activity maps and potentiodynamic movies of the heterogeneous surface of a catalyst. For example, by coupling SECCM data with colocated microscopy from electron backscatter diffraction (EBSD) or atomic force microscopy, it is possible to develop compelling correlations of (precatalyst) structure-activity at the nanoscale level. This correlative electrochemical multimicroscopy strategy allows the catalytically more active region of a catalyst, such as the edge plane of two-dimensional materials and the grain boundaries between facets in a polycrystalline metal, to be highlighted. The attributes of SECCM-EBSD are well-illustrated by detailed studies of the eCO2RR on polycrystalline gold, where carbon monoxide is the main product. Comparing SECCM maps and movies with EBSD images of the same region reveals unambiguously that the eCO2RR is enhanced at surface-terminating dislocations, which accumulate at grain boundaries and slip bands. Both FT ac voltammetry and SECCM techniques greatly enhance our understanding of the eCO2RR, significantly boosting the electrochemical toolbox and the information available for the development and testing of theoretical models and rational catalyst design. In the future, it may be possible to further enhance insights provided by both techniques through their integration with in situ and in operando spectroscopy and microscopy methods.
Collapse
Affiliation(s)
| | | | - Minkyung Kang
- Institute for Frontier Materials, Deakin University, Burwood, Victoria 3125, Australia
| | | | - Patrick R. Unwin
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, U.K
| | | |
Collapse
|
18
|
A review of optical methods for ultrasensitive detection and characterization of nanoparticles in liquid media with a focus on the wide field surface plasmon microscopy. Anal Chim Acta 2022; 1204:339633. [DOI: 10.1016/j.aca.2022.339633] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 02/16/2022] [Accepted: 02/17/2022] [Indexed: 12/27/2022]
|
19
|
Yamamoto T, Ando T, Kawabe Y, Fukuma T, Enomoto H, Nishijima Y, Matsui Y, Kanamura K, Takahashi Y. Characterization of the Depth of Discharge-Dependent Charge Transfer Resistance of a Single LiFePO 4 Particle. Anal Chem 2021; 93:14448-14453. [PMID: 34668693 DOI: 10.1021/acs.analchem.1c02851] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
The discharged state affects the charge transfer resistance of lithium-ion secondary batteries (LIBs), which is referred to as the depth of discharge (DOD). To understand the intrinsic charge/discharge property of LIBs, the DOD-dependent charge transfer resistance at the solid-liquid interface is required. However, in a general composite electrode, the conductive additive and organic polymeric binder are unevenly distributed, resulting in a complicated electron conduction/ion conduction path. As a result, estimating the DOD-dependent rate-determining factor of LIBs is difficult. In contrast, in micro/nanoscale electrochemical measurements, the primary or secondary particle is evaluated without using a conductive additive and providing an ideal mass transport condition. To control the DOD state of a single LiFePO4 active material and evaluate the DOD-dependent charge transfer kinetic parameters, we use scanning electrochemical cell microscopy (SECCM), which uses a micropipette to form an electrochemical cell on a sample surface. The difference in charge transfer resistance at the solid-liquid interface depending on the DOD state and electrolyte solution could be confirmed using SECCM.
Collapse
Affiliation(s)
| | - Tomohiro Ando
- Division of Electrical Engineering and Computer Science, Kanazawa University, Kanazawa 920-1192, Japan
| | - Yusuke Kawabe
- Division of Electrical Engineering and Computer Science, Kanazawa University, Kanazawa 920-1192, Japan
| | - Takeshi Fukuma
- Division of Electrical Engineering and Computer Science, Kanazawa University, Kanazawa 920-1192, Japan.,WPI Nano Life Science Institute (WPI-NanoLSI), Kanazawa University, Kanazawa 920-1192, Japan
| | - Hiroshi Enomoto
- Mechanical Science and Engineering, Kanazawa University, Kanazawa 920-1192, Japan
| | - Yoshiaki Nishijima
- Faculty of Engineering Department of Electrical and Electronics Engineering, Aichi Institute of Technology, Toyota 470-0392, Japan
| | | | | | - Yasufumi Takahashi
- Division of Electrical Engineering and Computer Science, Kanazawa University, Kanazawa 920-1192, Japan.,WPI Nano Life Science Institute (WPI-NanoLSI), Kanazawa University, Kanazawa 920-1192, Japan.,Precursory Research for Embryonic Science and Technology (PRESTO), Japan Science and Technology Agency (JST), Saitama 332-0012, Japan
| |
Collapse
|
20
|
Dorfi AE, Yan J, Wright J, Esposito DV. Compressed Sensing Image Reconstruction of Scanning Electrochemical Microscopy Measurements Carried Out at Ultrahigh Scan Speeds Using Continuous Line Probes. Anal Chem 2021; 93:12574-12581. [PMID: 34496203 DOI: 10.1021/acs.analchem.1c01869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Previous studies on scanning electrochemical microscopy (SECM) imaging with nonlocal continuous line probes (CLPs) have demonstrated the ability to increase areal imaging rates by an order of magnitude compared to SECM based on conventional ultramicroelectrode (UME) disk electrodes. Increasing the linear scan speed of the CLP during imaging presents an opportunity to increase imaging rates even further but results in a significant deterioration in image quality due to transport processes in the liquid electrolyte. Here, we show that compressed sensing (CS) postprocessing can be successfully applied to CLP-based SECM measurements to reconstruct images with minimal distortion at probe scan rates greatly exceeding the conventional SECM ″speed limit″. By systematically evaluating the image quality of images generated by adaptable postprocessing CS methods for CLP-SECM data collected at varying scan rates, this work establishes a new upper bound for CLP scan rates. While conventional SECM imaging typically uses probe scan speeds characterized by Péclet numbers (Pe) < 1, this study shows that CS postprocessing methods can allow for an accurate image reconstruction for Pe approaching 5, corresponding to an order of magnitude increase in the maximum probe scan speed. This upper limit corresponds to the onset of chaotic convective flows within the electrolyte for the probes investigated in this work, highlighting the importance of considering hydrodynamics in the design of fast-scanning probes.
Collapse
Affiliation(s)
- Anna E Dorfi
- Department of Chemical Engineering, Columbia University in the City of New York, 500 W. 120th St., New York, New York 10027, United States
| | - Jingkai Yan
- Department of Electrical Engineering, Columbia University in the City of New York, 500 W. 120th St., New York, New York 10027, United States.,Data Science Institute, Columbia University in the City of New York, Northwest Corner, 550 W 120th St. #1401, New York, New York 10027, United States
| | - John Wright
- Department of Chemical Engineering, Columbia University in the City of New York, 500 W. 120th St., New York, New York 10027, United States.,Data Science Institute, Columbia University in the City of New York, Northwest Corner, 550 W 120th St. #1401, New York, New York 10027, United States
| | - Daniel V Esposito
- Department of Chemical Engineering, Columbia University in the City of New York, 500 W. 120th St., New York, New York 10027, United States.,Columbia Electrochemical Energy Center, Columbia University in the City of New York, 500 W. 120th St., New York, New York 10027, United States.,Lenfest Center for Sustainable Energy, Columbia University in the City of New York, 500 W. 120th St., New York, New York 10027, United States
| |
Collapse
|
21
|
Shi M, Wang L, Xie Z, Zhao L, Zhang X, Zhang M. High-Content Label-Free Single-Cell Analysis with a Microfluidic Device Using Programmable Scanning Electrochemical Microscopy. Anal Chem 2021; 93:12417-12425. [PMID: 34464090 DOI: 10.1021/acs.analchem.1c02507] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The cellular heterogeneity and plasticity are often overlooked due to the averaged bulk assay in conventional methods. Optical imaging-based single-cell analysis usually requires specific labeling of target molecules inside or on the surface of the cell membrane, interfering with the physiological homeostasis of the cell. Scanning electrochemical microscopy (SECM), as an alternative approach, enables label-free imaging of single cells, which still confronts the challenge that the long-time scanning process is not feasible for large-scale analysis at the single-cell level. Herein, we developed a methodology combining a programmable SECM (P-SECM) with an addressable microwell array, which dramatically shortened the time consumption for the topography detection of the micropits array occupied by the polystyrene beads as well as the evaluation of alkaline phosphatase (ALP) activity of the 82 single cells compared with the traditional SECM imaging. This new arithmetic was based on the line scanning approach, enabling analysis of over 900 microwells within 1.2 h, which is 10 times faster than conventional SECM imaging. By implementing this configuration with the dual-mediator-based voltage-switching (VSM) mode, we investigated the activity of ALP, a promising marker for cancer stem cells, in hundreds of tumor and stromal cells on a single microwell device. The results discovered that not only a higher ALP activity is presented in cancer cells but also the heterogeneous distribution of kinetic constant (kf value) of ALP activity can be obtained at the single-cell level. By directly relating large numbers of addressed cells on the scalable microfluidic device to the deterministic routing of the above SECM tip, our platform holds potential as a high-content screening tool for label-free single-cell analysis.
Collapse
Affiliation(s)
- Mi Shi
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Lin Wang
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Zhenda Xie
- Institute for Advanced Study, Tsinghua University, Beijing 100084, China
| | - Liang Zhao
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, Beijing 100083, China.,Centre of Excellence for Environmental Safety and Biological Effects, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China
| | - Xueji Zhang
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, Beijing 100083, China.,School of Biomedical Engineering, Health Science Centre, Shenzhen University, Shenzhen, Guangdong 518060, China
| | - Meiqin Zhang
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, Beijing 100083, China
| |
Collapse
|
22
|
Klenerman D, Korchev Y, Novak P, Shevchuk A. Noncontact Nanoscale Imaging of Cells. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2021; 14:347-361. [PMID: 34314223 DOI: 10.1146/annurev-anchem-091420-120101] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The reduction in ion current as a fine pipette approaches a cell surface allows the cell surface topography to be imaged, with nanoscale resolution, without contact with the delicate cell surface. A variety of different methods have been developed and refined to scan the topography of the dynamic cell surface at high resolution and speed. Measurement of cell topography can be complemented by performing local probing or mapping of the cell surface using the same pipette. This can be done by performing single-channel recording, applying force, delivering agonists, using pipettes fabricated to contain an electrochemical probe, or combining with fluorescence imaging. These methods in combination have great potential to image and map the surface of live cells at the nanoscale.
Collapse
Affiliation(s)
- David Klenerman
- Department of Chemistry, University of Cambridge, Cambridge CB2 1EW, United Kingdom;
| | - Yuri Korchev
- Imperial College Faculty of Medicine, London Centre for Nanotechnology, London W12 0NN, United Kingdom
- Nano Life Science Institute (WPI-NanoLSI), Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan
| | - Pavel Novak
- Imperial College Faculty of Medicine, London Centre for Nanotechnology, London W12 0NN, United Kingdom
- National University of Science and Technology (MISiS), Moscow 119991, Russia
| | - Andrew Shevchuk
- Imperial College Faculty of Medicine, London Centre for Nanotechnology, London W12 0NN, United Kingdom
| |
Collapse
|
23
|
Bentley CL. Scanning electrochemical cell microscopy for the study of (nano)particle electrochemistry: From the sub‐particle to ensemble level. ELECTROCHEMICAL SCIENCE ADVANCES 2021. [DOI: 10.1002/elsa.202100081] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
|
24
|
Limani N, Boudet A, Blanchard N, Jousselme B, Cornut R. Local probe investigation of electrocatalytic activity. Chem Sci 2020; 12:71-98. [PMID: 34163583 PMCID: PMC8178752 DOI: 10.1039/d0sc04319b] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Accepted: 11/04/2020] [Indexed: 11/21/2022] Open
Abstract
As the world energy crisis remains a long-term challenge, development and access to renewable energy sources are crucial for a sustainable modern society. Electrochemical energy conversion devices are a promising option for green energy supply, although the challenge associated with electrocatalysis have caused increasing complexity in the materials and systems, demanding further research and insights. In this field, scanning probe microscopy (SPM) represents a specific source of knowledge and understanding. Thus, our aim is to present recent findings on electrocatalysts for electrolysers and fuel cells, acquired mainly through scanning electrochemical microscopy (SECM) and other related scanning probe techniques. This review begins with an introduction to the principles of several SPM techniques and then proceeds to the research done on various energy-related reactions, by emphasizing the progress on non-noble electrocatalytic materials.
Collapse
Affiliation(s)
- N Limani
- Université Paris-Saclay, CEA, CNRS, NIMBE, LICSEN Gif-sur-Yvette 91191 France
| | - A Boudet
- Université Paris-Saclay, CEA, CNRS, NIMBE, LICSEN Gif-sur-Yvette 91191 France
| | - N Blanchard
- Université Paris-Saclay, CEA, CNRS, NIMBE, LICSEN Gif-sur-Yvette 91191 France
| | - B Jousselme
- Université Paris-Saclay, CEA, CNRS, NIMBE, LICSEN Gif-sur-Yvette 91191 France
| | - R Cornut
- Université Paris-Saclay, CEA, CNRS, NIMBE, LICSEN Gif-sur-Yvette 91191 France
| |
Collapse
|
25
|
Shkirskiy V, Kang M, McPherson IJ, Bentley CL, Wahab OJ, Daviddi E, Colburn AW, Unwin PR. Electrochemical Impedance Measurements in Scanning Ion Conductance Microscopy. Anal Chem 2020; 92:12509-12517. [PMID: 32786472 DOI: 10.1021/acs.analchem.0c02358] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Electrochemical impedance spectroscopy (EIS) is a versatile tool for electrochemistry, particularly when applied locally to reveal the properties and dynamics of heterogeneous interfaces. A new method to generate local electrochemical impedance spectra is outlined, by applying a harmonic bias between a quasi-reference counter electrode (QRCE) placed in a nanopipet tip of a scanning ion conductance microscope (SICM) and a conductive (working electrode) substrate (two-electrode setup). The AC frequency can be tuned so that the magnitude of the impedance is sensitive to the tip-to-substrate distance, whereas the phase angle is broadly defined by the local capacitive response of the electrical double layer (EDL) of the working electrode. This development enables the surface topography and the local capacitance to be sensed reliably, and separately, in a single measurement. Further, self-referencing the probe impedance near the surface to that in the bulk solution allows the local capacitive response of the working electrode substrate in the overall AC signal to be determined, establishing a quantitative footing for the methodology. The spatial resolution of AC-SICM is an order of magnitude larger than the tip size (100 nm radius), for the studies herein, due to frequency dispersion. Comprehensive finite element method (FEM) modeling is undertaken to optimize the experimental conditions and minimize the experimental artifacts originating from the frequency dispersion phenomenon, and provides an avenue to explore the means by which the spatial resolution could be further improved.
Collapse
Affiliation(s)
- Viacheslav Shkirskiy
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Minkyung Kang
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Ian J McPherson
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Cameron L Bentley
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Oluwasegun J Wahab
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Enrico Daviddi
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Alex W Colburn
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Patrick R Unwin
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| |
Collapse
|
26
|
Dorfi AE, Zhou S, West AC, Wright J, Esposito DV. Probing the Speed Limits of Scanning Electrochemical Microscopy with In situ Colorimetric Imaging. ChemElectroChem 2020. [DOI: 10.1002/celc.202000476] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Anna E. Dorfi
- Department of Chemical Engineering, Columbia Electrochemical Energy Center, Lenfest Center for Sustainable EnergyColumbia University in the City of New York 500 W 120th Street New York NY 10027 USA
| | - Shijie Zhou
- Department of Electrical EngineeringColumbia University in the City of New York 500 W 120th Street New York NY 10027 USA
| | - Alan C. West
- Department of Chemical Engineering, Columbia Electrochemical Energy Center, Lenfest Center for Sustainable EnergyColumbia University in the City of New York 500 W 120th Street New York NY 10027 USA
| | - John Wright
- Department of Electrical EngineeringColumbia University in the City of New York 500 W 120th Street New York NY 10027 USA
| | - Daniel V. Esposito
- Department of Chemical Engineering, Columbia Electrochemical Energy Center, Lenfest Center for Sustainable EnergyColumbia University in the City of New York 500 W 120th Street New York NY 10027 USA
| |
Collapse
|
27
|
Alden SE, Siepser NP, Patterson JA, Jagdale GS, Choi M, Baker LA. Array Microcell Method (AMCM) for Serial Electroanalysis. ChemElectroChem 2020; 7:1084-1091. [PMID: 36588586 PMCID: PMC9798888 DOI: 10.1002/celc.201901976] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
We describe a method for electrochemical measurement and synthesis based on the combination of a mobile micropipette and a microelectrode array, which we term the array microcell method (AMCM). AMCM has the ability to address single electrodes within a microelectrode array (MEA) and provides a simple, low-cost format to enable versatile electrochemical measurements. In AMCM, a droplet at the tip of a movable micropipette (inner diameter of 50 μm) functions as an electrochemical cell, in which the electrode area is defined by a microelectrode of the array. We also report carbon MEAs that are well suited for AMCM and are fabricated from pyrolyzed photoresist films (PPFs). PPF-MEAs with nominal electrode diameters of 5.5 μm are characterized by AMCM, standard macroscale electrochemical methods, and finite element modeling. The versatility of AMCM is demonstrated by measurement of single Pt microparticles and by electrodeposition of shapecontrolled Pt nanoparticles.
Collapse
Affiliation(s)
- Sasha E Alden
- Department of Chemistry, Indiana University, 800 E Kirkwood, Bloomington, 47405, Indiana (USA)
| | - Natasha P Siepser
- Department of Chemistry, Indiana University, 800 E Kirkwood, Bloomington, 47405, Indiana (USA)
| | - Jacqueline A Patterson
- Department of Chemistry, Indiana University, 800 E Kirkwood, Bloomington, 47405, Indiana (USA)
| | - Gargi S Jagdale
- Department of Chemistry, Indiana University, 800 E Kirkwood, Bloomington, 47405, Indiana (USA)
| | - Myunghoon Choi
- Department of Chemistry, Indiana University, 800 E Kirkwood, Bloomington, 47405, Indiana (USA)
| | - Lane A Baker
- Department of Chemistry, Indiana University, 800 E Kirkwood, Bloomington, 47405, Indiana (USA)
| |
Collapse
|
28
|
Choi M, Siepser NP, Jeong S, Wang Y, Jagdale G, Ye X, Baker LA. Probing Single-Particle Electrocatalytic Activity at Facet-Controlled Gold Nanocrystals. NANO LETTERS 2020; 20:1233-1239. [PMID: 31917592 PMCID: PMC7727918 DOI: 10.1021/acs.nanolett.9b04640] [Citation(s) in RCA: 62] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Electrocatalytic reduction reactions (i.e., the hydrogen evolution reaction (HER) and oxygen reduction reaction) at individual, faceted Au nanocubes (NCs) and nano-octahedra (ODs) expressing predominantly {100} and {111} crystal planes on the surface, respectively, were studied by nanoscale voltammetric mapping. Cyclic voltammograms were collected at individual nanoparticles (NPs) with scanning electrochemical cell microscopy (SECCM) and correlated with particle morphology imaged by electron microscopy. Nanoscale measurements from a statistically informative set of individual NPs revealed that Au NCs have superior HER electrocatalytic activity compared to that of Au ODs, in good agreement with macroscale cyclic voltammetry measurements. Au NCs exhibited more particle-to-particle variation in catalytic activity compared to that with Au ODs. The approach of single-particle SECCM imaging coupled with macroscale CV on well-defined NPs provides a powerful toolset for the design and activity assessment of nanoscale electrocatalysts.
Collapse
Affiliation(s)
- Myunghoon Choi
- Department of Chemistry , Indiana University , 800 E. Kirkwood Avenue , Bloomington , Indiana 47405 , United States
| | - Natasha P Siepser
- Department of Chemistry , Indiana University , 800 E. Kirkwood Avenue , Bloomington , Indiana 47405 , United States
| | - Soojin Jeong
- Department of Chemistry , Indiana University , 800 E. Kirkwood Avenue , Bloomington , Indiana 47405 , United States
| | - Yi Wang
- Department of Chemistry , Indiana University , 800 E. Kirkwood Avenue , Bloomington , Indiana 47405 , United States
| | - Gargi Jagdale
- Department of Chemistry , Indiana University , 800 E. Kirkwood Avenue , Bloomington , Indiana 47405 , United States
| | - Xingchen Ye
- Department of Chemistry , Indiana University , 800 E. Kirkwood Avenue , Bloomington , Indiana 47405 , United States
| | - Lane A Baker
- Department of Chemistry , Indiana University , 800 E. Kirkwood Avenue , Bloomington , Indiana 47405 , United States
| |
Collapse
|
29
|
Yule L, Shkirskiy V, Aarons J, West G, Shollock B, Bentley C, Unwin P. Nanoscale electrochemical visualization of grain-dependent anodic iron dissolution from low carbon steel. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2019.135267] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
30
|
Vaneckova T, Bezdekova J, Han G, Adam V, Vaculovicova M. Application of molecularly imprinted polymers as artificial receptors for imaging. Acta Biomater 2020; 101:444-458. [PMID: 31706042 DOI: 10.1016/j.actbio.2019.11.007] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 10/21/2019] [Accepted: 11/04/2019] [Indexed: 12/19/2022]
Abstract
Medical diagnostics aims at specific localization of molecular targets as well as detection of abnormalities associated with numerous diseases. Molecularly imprinted polymers (MIPs) represent an approach of creating a synthetic material exhibiting selective recognition properties toward the desired template. The fabricated target-specific MIPs are usually well reproducible, economically efficient, and stable under critical conditions as compared to routinely used biorecognition elements such as fluorescent proteins, antibodies, enzymes, or aptamers and can even be created to those targets for which no antibodies are available. In this review, we summarize the methods of polymer fabrication. Further, we provide key for selection of the core material with imaging function depending on the imaging modality used. Finally, MIP-based imaging applications are highlighted and presented in a comprehensive form from different aspects. STATEMENT OF SIGNIFICANCE: In this review, we summarize the methods of polymer fabrication. Key applications of Molecularly imprinted polymers (MIPs) in imaging are highlighted and discussed with regard to the selection of the core material for imaging as well as commonly used imaging targets. MIPs represent an approach of creating a synthetic material exhibiting selective recognition properties toward the desired template. The fabricated target-specific MIPs are usually well reproducible, economically efficient, and stable under critical conditions as compared to routinely used biorecognition elements, e.g., antibodies, fluorescent proteins, enzymes, or aptamers, and can even be created to those targets for which no antibodies are available.
Collapse
|
31
|
Daviddi E, Chen Z, Beam Massani B, Lee J, Bentley CL, Unwin PR, Ratcliff EL. Nanoscale Visualization and Multiscale Electrochemical Analysis of Conductive Polymer Electrodes. ACS NANO 2019; 13:13271-13284. [PMID: 31674763 DOI: 10.1021/acsnano.9b06302] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Conductive polymers are exceptionally promising for modular electrochemical applications including chemical sensors, bioelectronics, redox-flow batteries, and photoelectrochemical systems due to considerable synthetic tunability and ease of processing. Despite well-established structural heterogeneity in these systems, conventional macroscopic electroanalytical methods-specifically cyclic voltammetry-are typically used as the primary tool for structure-property elucidation. This work presents an alternative correlative multimicroscopy strategy. Data from laboratory and synchrotron-based microspectroscopies, including conducting-atomic force microscopy and synchrotron nanoscale infrared spectroscopy, are combined with potentiodynamic movies of electrochemical fluxes from scanning electrochemical cell microscopy (SECCM) to reveal the relationship between electrode structure and activity. A model conductive polymer electrode system of tailored heterogeneity is investigated, consisting of phase-segregated domains of poly(3-hexylthiophene) (P3HT) surrounded by contiguous regions of insulating poly(methyl methacrylate) (PMMA), representing an ultramicroelectrode array. Isolated domains of P3HT are shown to retain bulk-like chemical and electronic structure when blended with PMMA and possess approximately equivalent electron-transfer rate constants compared to pure P3HT electrodes. The nanoscale electrochemical data are used to model and predict multiscale electrochemical behavior, revealing that macroscopic cyclic voltammograms should be much more kinetically facile than observed experimentally. This indicates that parasitic resistances rather than redox kinetics play a dominant role in macroscopic measurements in these conductive polymer systems. SECCM further demonstrates that the ambient degradation of the P3HT electroactivity within P3HT/PMMA blends is spatially heterogeneous. This work serves as a roadmap for benchmarking the quality of conductive polymer films as electrodes, emphasizing the importance of nanoscale electrochemical measurements in understanding macroscopic properties.
Collapse
Affiliation(s)
- Enrico Daviddi
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , United Kingdom
| | - Zhiting Chen
- Department of Materials Science and Engineering , University of Arizona , Tucson , Arizona 85721 , United States
| | - Brooke Beam Massani
- Department of Chemistry and Biochemistry , University of Arizona , Tucson , Arizona 85721 , United States
| | - Jaemin Lee
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , United Kingdom
| | - Cameron L Bentley
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , United Kingdom
| | - Patrick R Unwin
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , United Kingdom
| | - Erin L Ratcliff
- Department of Materials Science and Engineering , University of Arizona , Tucson , Arizona 85721 , United States
| |
Collapse
|
32
|
Ornelas IM, Unwin PR, Bentley CL. High-Throughput Correlative Electrochemistry-Microscopy at a Transmission Electron Microscopy Grid Electrode. Anal Chem 2019; 91:14854-14859. [PMID: 31674764 DOI: 10.1021/acs.analchem.9b04028] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
As part of the revolution in electrochemical nanoscience, there is growing interest in using electrochemistry to create nanostructured materials and to assess properties at the nanoscale. Herein, we present a platform that combines scanning electrochemical cell microscopy with ex situ scanning transmission electron microscopy to allow the ready creation of an array of nanostructures coupled with atomic-scale analysis. As an illustrative example, we explore the electrodeposition of Pt at carbon-coated transmission electron microscopy (TEM) grid supports, where in a single high-throughput experiment it is shown that Pt nanoparticle (PtNP) density increases and size polydispersity decreases with increasing overpotential (i.e., driving force). Furthermore, the coexistence of a range of nanostructures, from single atoms to aggregates of crystalline PtNPs, during the early stages of electrochemical nucleation and growth supports a nonclassical aggregative growth mechanism. Beyond this exemplary system, the presented correlative electrochemistry-microscopy approach is generally applicable to solve ubiquitous structure-function problems in electrochemical science and beyond, positioning it as a powerful platform for the rational design of functional nanomaterials.
Collapse
Affiliation(s)
- Isabel M Ornelas
- Nanoscale Physics Research Laboratory , University of Birmingham , Birmingham B15 2TT , United Kingdom
| | - Patrick R Unwin
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , United Kingdom
| | - Cameron L Bentley
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , United Kingdom
| |
Collapse
|
33
|
Martín-Yerga D, Costa-García A, Unwin PR. Correlative Voltammetric Microscopy: Structure-Activity Relationships in the Microscopic Electrochemical Behavior of Screen Printed Carbon Electrodes. ACS Sens 2019; 4:2173-2180. [PMID: 31353890 DOI: 10.1021/acssensors.9b01021] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Screen-printed carbon electrodes (SPCEs) are widely used for electrochemical sensors. However, little is known about their electrochemical behavior at the microscopic level. In this work, we use voltammetric scanning electrochemical cell microscopy (SECCM), with dual-channel probes, to determine the microscopic factors governing the electrochemical response of SPCEs. SECCM cyclic voltammetry (CV) measurements are performed directly in hundreds of different locations of SPCEs, with high spatial resolution, using a submicrometer sized probe. Further, the localized electrode activity is spatially correlated to colocated surface structure information from scanning electron microscopy and micro-Raman spectroscopy. This approach is applied to two model electrochemical processes: hexaammineruthenium(III/II) ([Ru(NH3)6]3+/2+), a well-known outer-sphere redox couple, and dopamine (DA), which undergoes a more complex electron-proton coupled electro-oxidation, with complications from adsorption of both DA and side-products. The electrochemical reduction of [Ru(NH3)6]3+ proceeds fairly uniformly across the surface of SPCEs on the submicrometer scale. In contrast, DA electro-oxidation shows a strong dependence on the microstructure of the SPCE. By studying this process at different concentrations of DA, the relative contributions of (i) intrinsic electrode kinetics and (ii) adsorption of DA are elucidated in detail, as a function of local electrode character and surface structure. These studies provide major new insights on the electrochemical activity of SPCEs and further position voltammetric SECCM as a powerful technique for the electrochemical imaging of complex, heterogeneous, and topographically rough electrode surfaces.
Collapse
Affiliation(s)
- Daniel Martín-Yerga
- Department of Physical and Analytical Chemistry, University of Oviedo, Julián Clavería, Oviedo 33006, Spain
| | - Agustín Costa-García
- Department of Physical and Analytical Chemistry, University of Oviedo, Julián Clavería, Oviedo 33006, Spain
| | - Patrick R. Unwin
- Department of Chemistry, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL, United Kingdom
| |
Collapse
|
34
|
Dorfi AE, Kuo HW, Smirnova V, Wright J, Esposito DV. Design and operation of a scanning electrochemical microscope for imaging with continuous line probes. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2019; 90:083702. [PMID: 31472628 DOI: 10.1063/1.5095951] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Accepted: 07/18/2019] [Indexed: 06/10/2023]
Abstract
This article describes a home-built scanning electrochemical microscope capable of achieving high areal imaging rates through the use of continuous line probes (CLPs) and compressed sensing (CS) image reconstruction. The CLP is a nonlocal probe consisting of a band electrode, where the achievable spatial resolution is set by the thickness of the band and the achievable imaging rate is largely determined by its width. A combination of linear and rotational motors allows for CLP scanning at different angles over areas up to 25 cm2 to generate the raw signal necessary to reconstruct the desired electrochemical image using CS signal analysis algorithms. Herein, we provide detailed descriptions of CLP fabrication, microscope design, and the procedures used to carry out scanning electrochemical microscopy imaging with CLPs. In order to illustrate the basic operating procedures for the microscope, line scans and images measured in the substrate generation-probe-collection mode for flat samples containing platinum disk electrodes are presented. These exemplary measurements illustrate methods for calibrating the positioning system, positioning and cleaning the CLP, and verifying proper positioning/probe sensitivity along its length.
Collapse
Affiliation(s)
- Anna E Dorfi
- Department of Chemical Engineering, Columbia Electrochemical Energy Center, Lenfest Center for Sustainable Energy, Columbia University in the City of New York, New York, New York 10027, USA
| | - Han-Wen Kuo
- Department of Electrical Engineering, Data Science Institute, Columbia University in the City of New York, New York, New York 10027, USA
| | - Vera Smirnova
- Department of Chemical Engineering, Columbia Electrochemical Energy Center, Lenfest Center for Sustainable Energy, Columbia University in the City of New York, New York, New York 10027, USA
| | - John Wright
- Department of Electrical Engineering, Data Science Institute, Columbia University in the City of New York, New York, New York 10027, USA
| | - Daniel V Esposito
- Department of Chemical Engineering, Columbia Electrochemical Energy Center, Lenfest Center for Sustainable Energy, Columbia University in the City of New York, New York, New York 10027, USA
| |
Collapse
|
35
|
Daviddi E, Gonos KL, Colburn AW, Bentley CL, Unwin PR. Scanning Electrochemical Cell Microscopy (SECCM) Chronopotentiometry: Development and Applications in Electroanalysis and Electrocatalysis. Anal Chem 2019; 91:9229-9237. [PMID: 31251561 DOI: 10.1021/acs.analchem.9b02091] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Scanning electrochemical cell microscopy (SECCM) has been applied for nanoscale (electro)activity mapping in a range of electrochemical systems but so far has almost exclusively been performed in controlled-potential (amperometric/voltammetric) modes. Herein, we consider the use of SECCM operated in a controlled-current (galvanostatic or chronopotentiometric) mode, to synchronously obtain spatially resolved electrode potential (i.e., electrochemical activity) and topographical "maps". This technique is first applied, as proof of concept, to study the electrochemically reversible [Ru(NH3)6]3+/2+ electron transfer process at a glassy carbon electrode surface, where the experimental data are in good agreement with well-established chronopotentiometric theory under quasi-radial diffusion conditions. The [Ru(NH3)6]3+/2+ process has also been imaged at "aged" highly ordered pyrolytic graphite (HOPG), where apparently enhanced electrochemical activity is measured at the edge plane relative to the basal plane surface, consistent with potentiostatic measurements. Finally, chronopotentiometric SECCM has been employed to benchmark a promising electrocatalytic system, the hydrogen evolution reaction (HER) at molybdenum disulfide (MoS2), where higher electrocatalytic activity (i.e., lower overpotential at a current density of 2 mA cm-2) is observed at the edge plane compared to the basal plane surface. These results are in excellent agreement with previous controlled-potential SECCM studies, confirming the viability of the technique and thereby opening up new possibilities for the use of chronopotentiometric methods for quantitative electroanalysis at the nanoscale, with promising applications in energy storage (battery) studies, electrocatalyst benchmarking, and corrosion research.
Collapse
Affiliation(s)
- Enrico Daviddi
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , U.K
| | - Katerina L Gonos
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , U.K
| | - Alex W Colburn
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , U.K
| | - Cameron L Bentley
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , U.K
| | - Patrick R Unwin
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , U.K
| |
Collapse
|
36
|
Zhuang J, Wang Z, Liao X, Gao B, Cheng L. Hierarchical spiral-scan trajectory for efficient scanning ion conductance microscopy. Micron 2019; 123:102683. [PMID: 31129536 DOI: 10.1016/j.micron.2019.102683] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Revised: 05/15/2019] [Accepted: 05/16/2019] [Indexed: 10/26/2022]
Abstract
Scanning ion conductance microscopy (SICM) is an emerging technique for non-contact, high-resolution topography imaging, especially suitable for live cells investigation in a physiological environment. Despite its rapid development, the extended acquisition time issues of its typical hopping/backstep scanning mode still restrict its application for more fields. Herein, we propose a novel SICM scanning approach to effectively reduce the retract distance of existing hopping/backstep mode. In this approach, the SICM probe first gradually descends in the z-direction. Then by using Archimedes spiral trajectory, which has the advantage of higher angular velocity due to its continuous and smooth trajectory, the probe rapidly detects the highest point of the sample in the xy-plane in a layer-by-layer way. Further, the maximum height that decides the retrace distance of pipet in the detected region can be quickly achieved, avoiding a huge retrace distance usually adopted in the existing methods without any prior knowledge (sample height and steepness in the scanning region). Therefore, this new scanning method can greatly reduce the imaging time by minimizing the retrace height of each measurement point. Theoretical analysis is conducted to compare the imaging time of traditional and new method. And various factors in the new method that affect the imaging speed are analyzed. In addition, PDMS (polydimethylsiloxane) and biological samples (C2C12 cells) were imaged by SICM that was operated in the hopping mode, raster-based detecting and developed method with a single-barrel pipet, respectively. The experimental results suggest that the new method has a faster imaging speed than conventional scanning modes but does not sacrifice the imaging quality.
Collapse
Affiliation(s)
- Jian Zhuang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an, 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China.
| | - Zhiwu Wang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an, 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China
| | - Xiaobo Liao
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an, 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China; School of Manufacturing Science and Engineering, Southwest University of Science and Technology, Mianyang, 621010, China
| | - Bingli Gao
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an, 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China
| | - Lei Cheng
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an, 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China
| |
Collapse
|
37
|
Defnet PA, Han C, Zhang B. Temporally-Resolved Ultrafast Hydrogen Adsorption and Evolution on Single Platinum Nanoparticles. Anal Chem 2019; 91:4023-4030. [DOI: 10.1021/acs.analchem.8b05463] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Peter A. Defnet
- Department of Chemistry, University of Washington, Seattle, Washington 98195, United States
| | - Chu Han
- Department of Chemistry, University of Washington, Seattle, Washington 98195, United States
| | - Bo Zhang
- Department of Chemistry, University of Washington, Seattle, Washington 98195, United States
| |
Collapse
|
38
|
Hui J, Gossage ZT, Sarbapalli D, Hernández-Burgos K, Rodríguez-López J. Advanced Electrochemical Analysis for Energy Storage Interfaces. Anal Chem 2018; 91:60-83. [PMID: 30428255 DOI: 10.1021/acs.analchem.8b05115] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
- Jingshu Hui
- Department of Chemistry , University of Illinois at Urbana-Champaign , 600 South Mathews Avenue , Urbana , Illinois 61801 , United States
| | - Zachary T Gossage
- Department of Chemistry , University of Illinois at Urbana-Champaign , 600 South Mathews Avenue , Urbana , Illinois 61801 , United States
| | - Dipobrato Sarbapalli
- Department of Materials Science and Engineering , University of Illinois at Urbana-Champaign , 1304 West Green Street , Urbana , Illinois 61801 , United States
| | - Kenneth Hernández-Burgos
- Department of Chemistry , University of Illinois at Urbana-Champaign , 600 South Mathews Avenue , Urbana , Illinois 61801 , United States.,Beckman Institute for Advanced Science and Technology , 405 North Mathews Avenue , Urbana , Illinois 61801 , United States
| | - Joaquín Rodríguez-López
- Department of Chemistry , University of Illinois at Urbana-Champaign , 600 South Mathews Avenue , Urbana , Illinois 61801 , United States.,Beckman Institute for Advanced Science and Technology , 405 North Mathews Avenue , Urbana , Illinois 61801 , United States
| |
Collapse
|
39
|
Bentley CL, Edmondson J, Meloni GN, Perry D, Shkirskiy V, Unwin PR. Nanoscale Electrochemical Mapping. Anal Chem 2018; 91:84-108. [PMID: 30500157 DOI: 10.1021/acs.analchem.8b05235] [Citation(s) in RCA: 94] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
40
|
Bentley CL, Kang M, Unwin PR. Nanoscale Surface Structure–Activity in Electrochemistry and Electrocatalysis. J Am Chem Soc 2018; 141:2179-2193. [DOI: 10.1021/jacs.8b09828] [Citation(s) in RCA: 139] [Impact Index Per Article: 23.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
| | - Minkyung Kang
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, U.K
| | - Patrick R. Unwin
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, U.K
| |
Collapse
|
41
|
Neves MMPDS, Martín-Yerga D. Advanced Nanoscale Approaches to Single-(Bio)entity Sensing and Imaging. BIOSENSORS 2018; 8:E100. [PMID: 30373209 PMCID: PMC6316691 DOI: 10.3390/bios8040100] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2018] [Revised: 10/11/2018] [Accepted: 10/23/2018] [Indexed: 01/01/2023]
Abstract
Individual (bio)chemical entities could show a very heterogeneous behaviour under the same conditions that could be relevant in many biological processes of significance in the life sciences. Conventional detection approaches are only able to detect the average response of an ensemble of entities and assume that all entities are identical. From this perspective, important information about the heterogeneities or rare (stochastic) events happening in individual entities would remain unseen. Some nanoscale tools present interesting physicochemical properties that enable the possibility to detect systems at the single-entity level, acquiring richer information than conventional methods. In this review, we introduce the foundations and the latest advances of several nanoscale approaches to sensing and imaging individual (bio)entities using nanoprobes, nanopores, nanoimpacts, nanoplasmonics and nanomachines. Several (bio)entities such as cells, proteins, nucleic acids, vesicles and viruses are specifically considered. These nanoscale approaches provide a wide and complete toolbox for the study of many biological systems at the single-entity level.
Collapse
Affiliation(s)
| | - Daniel Martín-Yerga
- Department of Chemical Engineering, KTH Royal Institute of Technology, 100-44 Stockholm, Sweden.
| |
Collapse
|
42
|
O’Neil GD, Kuo HW, Lomax DN, Wright J, Esposito DV. Scanning Line Probe Microscopy: Beyond the Point Probe. Anal Chem 2018; 90:11531-11537. [DOI: 10.1021/acs.analchem.8b02852] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Affiliation(s)
- Glen D. O’Neil
- Department of Chemical Engineering, Columbia University in the City of New York, New York, New York 10027, United States
| | - Han-wen Kuo
- Department of Electrical Engineering, Data Science Institute, Columbia University in the City of New York, New York, New York 10027, United States
| | - Duncan N. Lomax
- Department of Chemical Engineering, Columbia University in the City of New York, New York, New York 10027, United States
| | - John Wright
- Department of Electrical Engineering, Data Science Institute, Columbia University in the City of New York, New York, New York 10027, United States
| | - Daniel V. Esposito
- Department of Chemical Engineering, Columbia University in the City of New York, New York, New York 10027, United States
| |
Collapse
|
43
|
Dorwling-Carter L, Aramesh M, Han H, Zambelli T, Momotenko D. Combined Ion Conductance and Atomic Force Microscope for Fast Simultaneous Topographical and Surface Charge Imaging. Anal Chem 2018; 90:11453-11460. [DOI: 10.1021/acs.analchem.8b02569] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Affiliation(s)
- Livie Dorwling-Carter
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Zurich CH-8092, Switzerland
| | - Morteza Aramesh
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Zurich CH-8092, Switzerland
| | - Hana Han
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Zurich CH-8092, Switzerland
| | - Tomaso Zambelli
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Zurich CH-8092, Switzerland
| | - Dmitry Momotenko
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Zurich CH-8092, Switzerland
| |
Collapse
|
44
|
Huang L, Li Z, Lou Y, Cao F, Zhang D, Li X. Recent Advances in Scanning Electrochemical Microscopy for Biological Applications. MATERIALS (BASEL, SWITZERLAND) 2018; 11:E1389. [PMID: 30096895 PMCID: PMC6119995 DOI: 10.3390/ma11081389] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Revised: 07/24/2018] [Accepted: 07/28/2018] [Indexed: 12/17/2022]
Abstract
Scanning electrochemical microscopy (SECM) is a chemical microscopy technique with high spatial resolution for imaging sample topography and mapping specific chemical species in liquid environments. With the development of smaller, more sensitive ultramicroelectrodes (UMEs) and more precise computer-controlled measurements, SECM has been widely used to study biological systems over the past three decades. Recent methodological breakthroughs have popularized SECM as a tool for investigating molecular-level chemical reactions. The most common applications include monitoring and analyzing the biological processes associated with enzymatic activity and DNA, and the physiological activity of living cells and other microorganisms. The present article first introduces the basic principles of SECM, followed by an updated review of the applications of SECM in biological studies on enzymes, DNA, proteins, and living cells. Particularly, the potential of SECM for investigating bacterial and biofilm activities is discussed.
Collapse
Affiliation(s)
- Luyao Huang
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
| | - Ziyu Li
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
| | - Yuntian Lou
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
| | - Fahe Cao
- Department of Chemistry, Zhejiang University, Hangzhou 310027, China.
| | - Dawei Zhang
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
| | - Xiaogang Li
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
| |
Collapse
|
45
|
Wang Y, Shan X, Tao N. Emerging tools for studying single entity electrochemistry. Faraday Discuss 2018; 193:9-39. [PMID: 27722354 DOI: 10.1039/c6fd00180g] [Citation(s) in RCA: 70] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Electrochemistry studies charge transfer and related processes at various microscopic structures (atomic steps, islands, pits and kinks on electrodes), and mesoscopic materials (nanoparticles, nanowires, viruses, vesicles and cells) made by nature and humans, involving ions and molecules. The traditional approach measures averaged electrochemical quantities of a large ensemble of these individual entities, including the microstructures, mesoscopic materials, ions and molecules. There is a need to develop tools to study single entities because a real system is usually heterogeneous, e.g., containing nanoparticles with different sizes and shapes. Even in the case of "homogeneous" molecules, they bind to different microscopic structures of an electrode, assume different conformations and fluctuate over time, leading to heterogeneous reactions. Here we highlight some emerging tools for studying single entity electrochemistry, discuss their strengths and weaknesses, and provide personal views on the need for tools with new capabilities for further advancing single entity electrochemistry.
Collapse
Affiliation(s)
- Yixian Wang
- Center for Biosensors and Bioelectronics, Biodesign Institute and School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, Arizona 85287, USA.
| | - Xiaonan Shan
- Center for Biosensors and Bioelectronics, Biodesign Institute and School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, Arizona 85287, USA.
| | - Nongjian Tao
- Center for Biosensors and Bioelectronics, Biodesign Institute and School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, Arizona 85287, USA. and State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
| |
Collapse
|
46
|
Zhang S, Li M, Su B, Shao Y. Fabrication and Use of Nanopipettes in Chemical Analysis. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2018; 11:265-286. [PMID: 29894227 DOI: 10.1146/annurev-anchem-061417-125840] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
This review summarizes progress in the fabrication, modification, characterization, and applications of nanopipettes since 2010. A brief history of nanopipettes is introduced, and the details of fabrication, modification, and characterization of nanopipettes are provided. Applications of nanopipettes in chemical analysis are the focus in several cases, including recent progress in imaging; in the study of single molecules, single nanoparticles, and single cells; in fundamental investigations of charge transfer (ion and electron) reactions at liquid/liquid interfaces; and as hyphenated techniques combined with other methods to study the mechanisms of complicated electrochemical reactions and to conduct bioanalysis.
Collapse
Affiliation(s)
- Shudong Zhang
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China;
| | - Mingzhi Li
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China;
| | - Bin Su
- Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China;
| | - Yuanhua Shao
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China;
| |
Collapse
|
47
|
Bentley CL, Perry D, Unwin PR. Stability and Placement of Ag/AgCl Quasi-Reference Counter Electrodes in Confined Electrochemical Cells. Anal Chem 2018; 90:7700-7707. [PMID: 29808685 DOI: 10.1021/acs.analchem.8b01588] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Nanoelectrochemistry is an important and growing branch of electrochemistry that encompasses a number of key research areas, including (electro)catalysis, energy storage, biomedical/environmental sensing, and electrochemical imaging. Nanoscale electrochemical measurements are often performed in confined environments over prolonged experimental time scales with nonisolated quasi-reference counter electrodes (QRCEs) in a simplified two-electrode format. Herein, we consider the stability of commonly used Ag/AgCl QRCEs, comprising an AgCl-coated wire, in a nanopipet configuration, which simulates the confined electrochemical cell arrangement commonly encountered in nanoelectrochemical systems. Ag/AgCl QRCEs possess a very stable reference potential even when used immediately after preparation and, when deployed in Cl- free electrolyte media (e.g., 0.1 M HClO4) in the scanning ion conductance microscopy (SICM) format, drift by only ca. 1 mV h-1 on the several hours time scale. Furthermore, contrary to some previous reports, when employed in a scanning electrochemical cell microscopy (SECCM) format (meniscus contact with a working electrode surface), Ag/AgCl QRCEs do not cause fouling of the surface (i.e., with soluble redox byproducts, such as Ag+) on at least the 6 h time scale, as long as suitable precautions with respect to electrode handling and placement within the nanopipet are observed. These experimental observations are validated through finite element method (FEM) simulations, which consider Ag+ transport within a nanopipet probe in the SECCM and SICM configurations. These results confirm that Ag/AgCl is a stable and robust QRCE in confined electrochemical environments, such as in nanopipets used in SICM, for nanopore measurements, for printing and patterning, and in SECCM, justifying the widespread use of this electrode in the field of nanoelectrochemistry and beyond.
Collapse
Affiliation(s)
- Cameron L Bentley
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , United Kingdom
| | - David Perry
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , United Kingdom
| | - Patrick R Unwin
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , United Kingdom
| |
Collapse
|
48
|
Advances and Perspectives in Chemical Imaging in Cellular Environments Using Electrochemical Methods. CHEMOSENSORS 2018. [DOI: 10.3390/chemosensors6020024] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
49
|
Imaging nanobubble nucleation and hydrogen spillover during electrocatalytic water splitting. Proc Natl Acad Sci U S A 2018; 115:5878-5883. [PMID: 29784824 DOI: 10.1073/pnas.1800945115] [Citation(s) in RCA: 76] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Nucleation and growth of hydrogen nanobubbles are key initial steps in electrochemical water splitting. These processes remain largely unexplored due to a lack of proper tools to probe the nanobubble's interfacial structure with sufficient spatial and temporal resolution. We report the use of superresolution microscopy to image transient formation and growth of single hydrogen nanobubbles at the electrode/solution interface during electrocatalytic water splitting. We found hydrogen nanobubbles can be generated even at very early stages in water electrolysis, i.e., ∼500 mV before reaching its thermodynamic reduction potential. The ability to image single nanobubbles on an electrode enabled us to observe in real time the process of hydrogen spillover from ultrathin gold nanocatalysts supported on indium-tin oxide.
Collapse
|
50
|
Stephens LI, Mauzeroll J. Altered Spatial Resolution of Scanning Electrochemical Microscopy Induced by Multifunctional Dual-Barrel Microelectrodes. Anal Chem 2018; 90:6796-6803. [DOI: 10.1021/acs.analchem.8b00821] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Affiliation(s)
- Lisa I. Stephens
- Laboratory for Electrochemical Reactive
Imaging and Detection of Biological Systems, Department of Chemistry, McGill University, Montreal, Quebec H3A 0B8, Canada
| | - Janine Mauzeroll
- Laboratory for Electrochemical Reactive
Imaging and Detection of Biological Systems, Department of Chemistry, McGill University, Montreal, Quebec H3A 0B8, Canada
| |
Collapse
|