1
|
Paul B, Kiel A, Otto M, Gemming T, Hoffmann V, Giebeler L, Kaltschmidt B, Hütten A, Gebert A, Kaltschmidt B, Kaltschmidt C, Hufenbach J. Inherent Antibacterial Properties of Biodegradable FeMnC(Cu) Alloys for Implant Application. ACS APPLIED BIO MATERIALS 2024; 7:839-852. [PMID: 38253353 PMCID: PMC10880094 DOI: 10.1021/acsabm.3c00835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 12/04/2023] [Accepted: 12/22/2023] [Indexed: 01/24/2024]
Abstract
Implant-related infections or inflammation are one of the main reasons for implant failure. Therefore, different concepts for prevention are needed, which strongly promote the development and validation of improved material designs. Besides modifying the implant surface by, for example, antibacterial coatings (also implying drugs) for deterring or eliminating harmful bacteria, it is a highly promising strategy to prevent such implant infections by antibacterial substrate materials. In this work, the inherent antibacterial behavior of the as-cast biodegradable Fe69Mn30C1 (FeMnC) alloy against Gram-negative Pseudomonas aeruginosa and Escherichia coli as well as Gram-positive Staphylococcus aureus is presented for the first time in comparison to the clinically applied, corrosion-resistant AISI 316L stainless steel. In the second step, 3.5 wt % Cu was added to the FeMnC reference alloy, and the microbial corrosion as well as the proliferation of the investigated bacterial strains is further strongly influenced. This leads for instance to enhanced antibacterial activity of the Cu-modified FeMnC-based alloy against the very aggressive, wild-type bacteria P. aeruginosa. For clarification of the bacterial test results, additional analyses were applied regarding the microstructure and elemental distribution as well as the initial corrosion behavior of the alloys. This was electrochemically investigated by a potentiodynamic polarization test. The initial degraded surface after immersion were analyzed by glow discharge optical emission spectrometry and transmission electron microscopy combined with energy-dispersive X-ray analysis, revealing an increase of degradation due to Cu alloying. Due to their antibacterial behavior, both investigated FeMnC-based alloys in this study are attractive as a temporary implant material.
Collapse
Affiliation(s)
- Birgit Paul
- Leibniz
Institute for Solid State and Materials Research Dresden, Helmholtzstr. 20, 01069 Dresden, Germany
| | - Annika Kiel
- Department
of Cell Biology, Faculty of Biology, Universität
Bielefeld, Universitätsstraße 25, 33615 Bielefeld, Germany
| | - Martin Otto
- Leibniz
Institute for Solid State and Materials Research Dresden, Helmholtzstr. 20, 01069 Dresden, Germany
- Institute
of Materials Science, Technische Universität
Bergakademie Freiberg, Gustav-Zeuner-Str. 5, 09599 Freiberg, Germany
| | - Thomas Gemming
- Leibniz
Institute for Solid State and Materials Research Dresden, Helmholtzstr. 20, 01069 Dresden, Germany
| | - Volker Hoffmann
- Leibniz
Institute for Solid State and Materials Research Dresden, Helmholtzstr. 20, 01069 Dresden, Germany
| | - Lars Giebeler
- Leibniz
Institute for Solid State and Materials Research Dresden, Helmholtzstr. 20, 01069 Dresden, Germany
| | - Bernhard Kaltschmidt
- Department
of Thin Films and Physics of Nanostructures, Center of Spinelectronic
Materials and Devices, Faculty of Physics, Universität Bielefeld, Universitätsstraße 25, 33615 Bielefeld, Germany
| | - Andreas Hütten
- Department
of Thin Films and Physics of Nanostructures, Center of Spinelectronic
Materials and Devices, Faculty of Physics, Universität Bielefeld, Universitätsstraße 25, 33615 Bielefeld, Germany
| | - Annett Gebert
- Leibniz
Institute for Solid State and Materials Research Dresden, Helmholtzstr. 20, 01069 Dresden, Germany
| | - Barbara Kaltschmidt
- Department
of Cell Biology, Faculty of Biology, Universität
Bielefeld, Universitätsstraße 25, 33615 Bielefeld, Germany
| | - Christian Kaltschmidt
- Department
of Cell Biology, Faculty of Biology, Universität
Bielefeld, Universitätsstraße 25, 33615 Bielefeld, Germany
| | - Julia Hufenbach
- Leibniz
Institute for Solid State and Materials Research Dresden, Helmholtzstr. 20, 01069 Dresden, Germany
- Institute
of Materials Science, Technische Universität
Bergakademie Freiberg, Gustav-Zeuner-Str. 5, 09599 Freiberg, Germany
| |
Collapse
|
2
|
Rawat N, Benčina M, Paul D, Kovač J, Lakota K, Žigon P, Kralj-Iglič V, Ho HC, Vukomanović M, Iglič A, Junkar I. Fine-Tuning the Nanostructured Titanium Oxide Surface for Selective Biological Response. ACS APPLIED BIO MATERIALS 2023; 6:5481-5492. [PMID: 38062750 PMCID: PMC10731649 DOI: 10.1021/acsabm.3c00686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Revised: 11/07/2023] [Accepted: 11/20/2023] [Indexed: 12/19/2023]
Abstract
Cardiovascular diseases are a pre-eminent global cause of mortality in the modern world. Typically, surgical intervention with implantable medical devices such as cardiovascular stents is deployed to reinstate unobstructed blood flow. Unfortunately, existing stent materials frequently induce restenosis and thrombosis, necessitating the development of superior biomaterials. These biomaterials should inhibit platelet adhesion (mitigating stent-induced thrombosis) and smooth muscle cell proliferation (minimizing restenosis) while enhancing endothelial cell proliferation at the same time. To optimize the surface properties of Ti6Al4V medical implants, we investigated two surface treatment procedures: gaseous plasma treatment and hydrothermal treatment. We analyzed these modified surfaces through scanning electron microscopy (SEM), water contact angle analysis (WCA), X-ray photoelectron spectroscopy (XPS), and X-ray diffraction (XRD) analysis. Additionally, we assessed in vitro biological responses, including platelet adhesion and activation, as well as endothelial and smooth muscle cell proliferation. Herein, we report the influence of pre/post oxygen plasma treatment on titanium oxide layer formation via a hydrothermal technique. Our results indicate that alterations in the titanium oxide layer and surface nanotopography significantly influence cell interactions. This work offers promising insights into designing multifunctional biomaterial surfaces that selectively promote specific cell types' proliferation─which is a crucial advancement in next-generation vascular implants.
Collapse
Affiliation(s)
- Niharika Rawat
- Laboratory
of Physics, Faculty of Electrical Engineering,
University of Ljubljana, Tržaška 25, SI-1000 Ljubljana, Slovenia
| | - Metka Benčina
- Laboratory
of Physics, Faculty of Electrical Engineering,
University of Ljubljana, Tržaška 25, SI-1000 Ljubljana, Slovenia
- Department
of Surface Engineering, Jožef Stefan
Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
| | - Domen Paul
- Department
of Surface Engineering, Jožef Stefan
Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
| | - Janez Kovač
- Department
of Surface Engineering, Jožef Stefan
Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
| | - Katja Lakota
- Department
of Rheumatology, University Medical Centre
Ljubljana, Vodnikova 62, SI-1000 Ljubljana, Slovenia
| | - Polona Žigon
- Department
of Rheumatology, University Medical Centre
Ljubljana, Vodnikova 62, SI-1000 Ljubljana, Slovenia
| | - Veronika Kralj-Iglič
- Laboratory
of Clinical Biophysics, Faculty of Health
Sciences, University of Ljubljana, Zdravstvena pot 5, SI-1000 Ljubljana, Slovenia
| | - Hsin-Chia Ho
- Advanced
Materials Department, Jožef Stefan
Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
| | - Marija Vukomanović
- Advanced
Materials Department, Jožef Stefan
Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
| | - Aleš Iglič
- Laboratory
of Physics, Faculty of Electrical Engineering,
University of Ljubljana, Tržaška 25, SI-1000 Ljubljana, Slovenia
- Chair of
Orthopaedic Surgery, Faculty of Medicine, University of Ljubljana, Vrazov trg 2, SI-1000 Ljubljana, Slovenia
| | - Ita Junkar
- Department
of Surface Engineering, Jožef Stefan
Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
| |
Collapse
|