1
|
Gupta A, Rotake D, Darji A. Sensing lead ions in water: a comprehensive review on strategies and sensor materials. ANAL SCI 2024; 40:997-1021. [PMID: 38523231 DOI: 10.1007/s44211-024-00547-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 02/25/2024] [Indexed: 03/26/2024]
Abstract
It is well-known fact that elevated lead ions (Pb2+), the third most toxic among heavy metal ions in aqueous systems, pose a threat to human health and aquatic ecosystems when they exceed permissible limits. Pb2+ is commonly found in industrial waste and fertilizers, contaminating water sources and subsequently entering the human body, causing various adverse health conditions. Unlike being expelled, Pb2+ accumulates within the body, posing potential health risks. The harmful impact of presence of Pb2+ in water have prompted researchers to diligently work toward maintaining water quality. Recognizing the importance of Pb2+, this review article makes a sincere and effective effort to address the issues associated with Pb2+. This overview article gives insights into various sensing approaches to detect Pb2+ in water using different sensing materials, including 2-dimensional materials, thiols, quantum dots, and polymers. Herein, different sensing approaches such as electrochemical, optical, field effect transistor-based, micro-electromechanical system-based, and chemi resistive are thoroughly explained. Field effect transistor-based and chemiresistive work on similar principles and are compared on the basis of their fabrication processes and sensing capabilities. In conclusion, future directions for chemiresistive sensors in Pb2+ detection are proposed, emphasizing their simplicity, portability, straightforward functionality, and ease of fabrication. Notably, it sheds light on various thiol and ligand compounds and coupling strategies utilized in Pb2+ detection. This comprehensive study is expected to benefit individuals engaged in Pb2+ detection.
Collapse
Affiliation(s)
- Anju Gupta
- Department of Electronics Engineering, Sardar Vallabhbhai National Institute of Technology, Ichchhanath, Surat, 395007, Gujarat, India
- Department of Biomedical Engineering, Shri Ramdeobaba College of Engineering and Management, Ramdeo Tekdi, Nagpur, 440013, Maharashtra, India
| | - Dinesh Rotake
- Department of Electrical Engineering, Indian Institute of Technology Hyderabad, Kandi, Sangareddy, Hyderabad, 502284, Telangana, India.
| | - Anand Darji
- Department of Electronics Engineering, Sardar Vallabhbhai National Institute of Technology, Ichchhanath, Surat, 395007, Gujarat, India
| |
Collapse
|
2
|
Du W, Dong Y, Wang Z, Yao S, Wang M, Ji J, Ruan H, Quan R. Study on the mechanism of cadmium chloride pollution accelerating skin tissue metabolism disorder, aging and inhibiting hair regeneration. Front Public Health 2022; 10:1035301. [PMID: 36339210 PMCID: PMC9627278 DOI: 10.3389/fpubh.2022.1035301] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Accepted: 10/04/2022] [Indexed: 01/29/2023] Open
Abstract
Drinking water contaminated by Cd2+ is one of the main pathways for Cd to enter the body. The skin barrier is destroyed when the skin is contaminated by environmental Cd2+, however, the detailed mechanism by which Cd2+ induces skin metabolic disorder, and senescence and affects hair regeneration is not completely understood. In this study, 18 C57BL/6 mice were randomly divided into a Control group, a Low-dose group, and a High-dose group with 6 mice in each group, and intragastrically administered with different concentrations of cadmium chloride once a day, respectively. After 1 month of intervention, the skin tissues on the back of mice were collected for non-targeted metabolomics analysis, and the related proteins were detected by immunofluorescence assay. Non-targeted metabolomics analysis result showed that compared with the Control group, there were 29 different metabolites, mainly including lysophospholipids, fatty acids, and bile acids, in the Low-dose group, and 39 differential metabolites in the High-dose group, in addition to the above compounds, there were more amino acid compounds, and most of the metabolites had a reduced response after administration. Immunofluorescence assay result showed that the higher the concentration of cadmium chloride led to the more obvious the proliferation inhibition and apoptosis promotion effects of skin cells, and the more significant damage to hair follicle stem cells. Thus, our findings demonstrate that cadmium chloride pollution can accelerate skin metabolism disorder, and aging and impair hair regeneration.
Collapse
Affiliation(s)
- Weibin Du
- Research Institute of Orthopedics, The Affiliated Jiangnan Hospital of Zhejiang Chinese Medical University, Hangzhou, China,Hangzhou Xiaoshan Hospital of Traditional Chinese Medicine, Hangzhou, China,*Correspondence: Weibin Du
| | - Yi Dong
- Shaoxing Traditional Chinese Medicine Hospital Affiliated to Zhejiang Chinese Medical University, Shaoxing, China
| | - Zhenwei Wang
- Research Institute of Orthopedics, The Affiliated Jiangnan Hospital of Zhejiang Chinese Medical University, Hangzhou, China,Hangzhou Xiaoshan Hospital of Traditional Chinese Medicine, Hangzhou, China
| | - Sai Yao
- Institute of Orthopedics and Traumatology, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, China,The First Clinical College of Zhejiang Chinese Medical University, Hangzhou, China
| | - Meijiao Wang
- School of Basic Medicine Sciences, Zhejiang Chinese Medical University, Hangzhou, China
| | - Jinjun Ji
- School of Basic Medicine Sciences, Zhejiang Chinese Medical University, Hangzhou, China
| | - Hongfeng Ruan
- Institute of Orthopedics and Traumatology, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, China,The First Clinical College of Zhejiang Chinese Medical University, Hangzhou, China,Hongfeng Ruan
| | - Renfu Quan
- Research Institute of Orthopedics, The Affiliated Jiangnan Hospital of Zhejiang Chinese Medical University, Hangzhou, China,Hangzhou Xiaoshan Hospital of Traditional Chinese Medicine, Hangzhou, China
| |
Collapse
|
3
|
Saha D, Angizi S, Darestani-Farahani M, Dalmieda J, Selvaganapathy PR, Kruse P. Tuning the Chemical and Mechanical Properties of Conductive MoS 2 Thin Films by Surface Modification with Aryl Diazonium Salts. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022; 38:3666-3675. [PMID: 35298176 PMCID: PMC8969871 DOI: 10.1021/acs.langmuir.1c03061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 02/04/2022] [Indexed: 05/14/2023]
Abstract
Molybdenum disulfide (MoS2) is a promising material for applications in sensors, energy storage, energy conversion devices, solar cells, and fuel cells. Because many of those applications require conductive materials, we recently developed a method for preparing a conductive form of MoS2 (c-MoS2) using dilute aqueous hydrogen peroxide in a simple and safe way. Here, we investigate modulating the chemical and mechanical surface properties of c-MoS2 thin films using diazonium chemistry. In addition to a direct passivation strategy of c-MoS2 with diazonium salts for electron-withdrawing groups, we also propose a novel in situ synthetic pathway for modification with electron-donating groups. The obtained results are examined by Raman spectroscopy and X-ray photoelectron spectroscopy. The degree of surface passivation of pristine and functionalized c-MoS2 films was tested by exposing them to aqueous solutions of different metal cations (Fe2+, Zn2+, Cu2+, and Co2+) and detecting the chemiresistive response. While pristine films were found to interact with several of the cations, modified films did not. We propose that a surface charge transfer mechanism is responsible for the chemiresistive response of the pristine films, while both modification routes succeeded at complete surface passivation. Functionalization was also found to lower the coefficient of friction for semiconducting 2H-MoS2, while all conductive materials (modified or not) also had lower coefficients of friction. This opens up a pathway to a palette of dry lubricant materials with improved chemical stability and tunable conductivity. Thus, both in situ and direct diazonium chemistries are powerful tools for tuning chemical and mechanical properties of conductive MoS2 for new devices and lubricants based on conductive MoS2.
Collapse
Affiliation(s)
- Dipankar Saha
- Department
of Chemistry and Chemical Biology, McMaster
University, Hamilton, Ontario L8S 4M1, Canada
| | - Shayan Angizi
- Department
of Chemistry and Chemical Biology, McMaster
University, Hamilton, Ontario L8S 4M1, Canada
| | - Maryam Darestani-Farahani
- Department
of Chemistry and Chemical Biology, McMaster
University, Hamilton, Ontario L8S 4M1, Canada
| | - Johnson Dalmieda
- Department
of Mechanical Engineering, McMaster University, Hamilton, Ontario L8S 4L7, Canada
| | - Ponnambalam Ravi Selvaganapathy
- Department
of Mechanical Engineering, McMaster University, Hamilton, Ontario L8S 4L7, Canada
- School
of Biomedical Engineering, McMaster University, Hamilton, Ontario L8S 4L8, Canada
| | - Peter Kruse
- Department
of Chemistry and Chemical Biology, McMaster
University, Hamilton, Ontario L8S 4M1, Canada
| |
Collapse
|
4
|
Zubiarrain-Laserna A, Angizi S, Akbar MA, Divigalpitiya R, Selvaganapathy PR, Kruse P. Detection of free chlorine in water using graphene-like carbon based chemiresistive sensors. RSC Adv 2022; 12:2485-2496. [PMID: 35425275 PMCID: PMC8979178 DOI: 10.1039/d1ra08264g] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Accepted: 01/12/2022] [Indexed: 01/02/2023] Open
Abstract
Free chlorine is the most commonly used water disinfectant. Measuring its concentration during and after water treatment is crucial to ensure its effectiveness. However, many of the existing methods do not allow for continuous on-line monitoring. Here we demonstrate a solid state chemiresistive sensor using graphene-like carbon (GLC) that overcomes that issue. GLC films that were either bare or non-covalently functionalized with the redox-active phenyl-capped aniline tetramer (PCAT) were successfully employed to quantify aqueous free chlorine, although functionalized devices showed better performance. The response of the sensors to increasing concentrations of free chlorine followed a Langmuir adsorption isotherm in the two tested ranges: 0.01–0.2 ppm and 0.2–1.4 ppm. The limit of detection was estimated to be 1 ppb, permitting the detection of breaches in chlorine filters. The devices respond to decreasing levels of free chlorine without the need for a reset, allowing for the continuous monitoring of fluctuations in the concentration. The maximum sensor response and saturation concentration were found to depend on the thickness of the GLC film. Hence, the sensitivity and dynamic range of the sensors can be tailored to different applications by adjusting the thickness of the films. Tap water samples from a residential area were tested using these sensors, which showed good agreement with standard colorimetric measurement methods. The devices did not suffer from interferences in the presence of ions commonly found in drinking water. Overall, these sensors are a cost-effective option for the continuous automated monitoring of free chlorine in drinking water. Chemiresistive sensors based on graphene-like carbon films are very stable and sensitive. They can be used for continuous online monitoring of free chlorine.![]()
Collapse
Affiliation(s)
- Ana Zubiarrain-Laserna
- Department of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada
| | - Shayan Angizi
- Department of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada
| | - Md Ali Akbar
- Department of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada
| | | | | | - Peter Kruse
- Department of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada
| |
Collapse
|
5
|
Falina S, Syamsul M, Rhaffor NA, Sal Hamid S, Mohamed Zain KA, Abd Manaf A, Kawarada H. Ten Years Progress of Electrical Detection of Heavy Metal Ions (HMIs) Using Various Field-Effect Transistor (FET) Nanosensors: A Review. BIOSENSORS 2021; 11:478. [PMID: 34940235 PMCID: PMC8699440 DOI: 10.3390/bios11120478] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 11/13/2021] [Accepted: 11/17/2021] [Indexed: 05/16/2023]
Abstract
Heavy metal pollution remains a major concern for the public today, in line with the growing population and global industrialization. Heavy metal ion (HMI) is a threat to human and environmental safety, even at low concentrations, thus rapid and continuous HMI monitoring is essential. Among the sensors available for HMI detection, the field-effect transistor (FET) sensor demonstrates promising potential for fast and real-time detection. The aim of this review is to provide a condensed overview of the contribution of certain semiconductor substrates in the development of chemical and biosensor FETs for HMI detection in the past decade. A brief introduction of the FET sensor along with its construction and configuration is presented in the first part of this review. Subsequently, the FET sensor deployment issue and FET intrinsic limitation screening effect are also discussed, and the solutions to overcome these shortcomings are summarized. Later, we summarize the strategies for HMIs' electrical detection, mechanisms, and sensing performance on nanomaterial semiconductor FET transducers, including silicon, carbon nanotubes, graphene, AlGaN/GaN, transition metal dichalcogenides (TMD), black phosphorus, organic and inorganic semiconductor. Finally, concerns and suggestions regarding detection in the real samples using FET sensors are highlighted in the conclusion.
Collapse
Affiliation(s)
- Shaili Falina
- Collaborative Microelectronic Design Excellence Center (CEDEC), Universiti Sains Malaysia, Sains@USM, Bayan Lepas 11900, Pulau Pinang, Malaysia; (S.F.); (N.A.R.); (S.S.H.); (K.A.M.Z.)
- Faculty of Science and Engineering, Waseda University, Tokyo 169-8555, Japan;
| | - Mohd Syamsul
- Faculty of Science and Engineering, Waseda University, Tokyo 169-8555, Japan;
- Institute of Nano Optoelectronics Research and Technology (INOR), Universiti Sains Malaysia, Sains@USM, Bayan Lepas 11900, Pulau Pinang, Malaysia
| | - Nuha Abd Rhaffor
- Collaborative Microelectronic Design Excellence Center (CEDEC), Universiti Sains Malaysia, Sains@USM, Bayan Lepas 11900, Pulau Pinang, Malaysia; (S.F.); (N.A.R.); (S.S.H.); (K.A.M.Z.)
| | - Sofiyah Sal Hamid
- Collaborative Microelectronic Design Excellence Center (CEDEC), Universiti Sains Malaysia, Sains@USM, Bayan Lepas 11900, Pulau Pinang, Malaysia; (S.F.); (N.A.R.); (S.S.H.); (K.A.M.Z.)
| | - Khairu Anuar Mohamed Zain
- Collaborative Microelectronic Design Excellence Center (CEDEC), Universiti Sains Malaysia, Sains@USM, Bayan Lepas 11900, Pulau Pinang, Malaysia; (S.F.); (N.A.R.); (S.S.H.); (K.A.M.Z.)
| | - Asrulnizam Abd Manaf
- Collaborative Microelectronic Design Excellence Center (CEDEC), Universiti Sains Malaysia, Sains@USM, Bayan Lepas 11900, Pulau Pinang, Malaysia; (S.F.); (N.A.R.); (S.S.H.); (K.A.M.Z.)
| | - Hiroshi Kawarada
- Faculty of Science and Engineering, Waseda University, Tokyo 169-8555, Japan;
- The Kagami Memorial Laboratory for Materials Science and Technology, Waseda University, 2-8-26 Nishiwaseda, Shinjuku, Tokyo 169-0051, Japan
| |
Collapse
|
6
|
Martinez Jimenez M, Avila A, de Barros A, Lopez EO, Alvarez F, Riul A, Perez-Taborda JA. Polyethyleneimine-Functionalized Carbon Nanotube/Graphene Oxide Composite: A Novel Sensing Platform for Pb(II) Acetate in Aqueous Solution. ACS OMEGA 2021; 6:18190-18199. [PMID: 34308050 PMCID: PMC8296609 DOI: 10.1021/acsomega.1c02085] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Accepted: 06/03/2021] [Indexed: 05/03/2023]
Abstract
Heavy metal pollution is posing a severe health risk on living organisms. Therefore, significant research efforts are focused on their detection. Here, we developed a sensing platform sensor for the selective detection of lead(II) acetate. The sensor is based on self-assembled polyethyleneimine-functionalized carbon nanotubes (PEI-CNTs) and graphene oxide films deposited onto gold interdigitated electrodes. The graphene-based nanostructure showed a resistive behavior, and the fabricated layer-by-layer film was used to detect Pb(II) acetate in an aqueous solution by comparison of three electrochemical methods: impedance spectroscopy, amperometry, and potentiometry stripping analysis. The results obtained from different methods show that the detection limit was down to 36 pmol/L and the sensitivity up to 4.3 μAL/μmol, with excellent repeatability. The detection mechanism was associated with the high affinity of heavy metal ions with the functional groups present in the PEI-CNTs and GO, allowing high performance and sensitivity. The achieved results are important for the research toward integrated monitoring and sensing platforms for Pb(II) contamination in drinking water.
Collapse
Affiliation(s)
- Mawin
J. Martinez Jimenez
- Colombian
Society of Engineering Physics (SCIF), Pereira 660003, Colombia
- Department
of Applied Physics, “Gleb Wataghin” Institute of Physics, University of Campinas—UNICAMP, Campinas 13083-970, São Paulo, Brazil
| | - Alba Avila
- Centro
de Microelectrónica (CMUA), Departamento de Ingeniería
Eléctrica y Electrónica, Universidad
de los Andes, Bogotá 111711, Colombia
| | - Anerise de Barros
- Laboratory
of Functional Materials, Institute of Chemistry, University of Campinas—UNICAMP, P.O. Box 6154, Campinas 13083-970, São Paulo, Brazil
| | - Elvis Oswaldo Lopez
- Department
of Experimental Low Energy Physics, Brazilian
Center for Research in Physics (CBPF), Rua Dr. Xavier Sigaud 150, Rio de Janeiro 22290-180, Brazil
| | - Fernando Alvarez
- Department
of Applied Physics, “Gleb Wataghin” Institute of Physics, University of Campinas—UNICAMP, Campinas 13083-970, São Paulo, Brazil
| | - Antonio Riul
- Department
of Applied Physics, “Gleb Wataghin” Institute of Physics, University of Campinas—UNICAMP, Campinas 13083-970, São Paulo, Brazil
| | - Jaime Andres Perez-Taborda
- Colombian
Society of Engineering Physics (SCIF), Pereira 660003, Colombia
- Centro
de Microelectrónica (CMUA), Departamento de Ingeniería
Eléctrica y Electrónica, Universidad
de los Andes, Bogotá 111711, Colombia
| |
Collapse
|
7
|
Yadav A, Kumar A, Verma N. Microchannel–engraved and Cu–dispersed carbon nanocomposite film as a chemiresistive sensor for aqueous metal ions. Chem Eng Sci 2021. [DOI: 10.1016/j.ces.2020.116282] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
8
|
Nguyen EP, de Carvalho Castro Silva C, Merkoçi A. Recent advancement in biomedical applications on the surface of two-dimensional materials: from biosensing to tissue engineering. NANOSCALE 2020; 12:19043-19067. [PMID: 32960195 DOI: 10.1039/d0nr05287f] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
As biosensors and biomedical devices have become increasingly important to everyday diagnostics and monitoring, there are tremendous, and constant efforts towards developing and improving the reliability and versatility of such technology. As they offer high surface area-to-volume ratios and a diverse range of properties, from electronic to optical, two dimensional (2D) materials have proven to be very promising candidates for biological applications and technologies. Due to the dimensionality, 2D materials facilitate many interfacial phenomena that have shown to significantly improve the performance of biosensors, while recent advances in synthesis techniques and surface engineering methods also enable the realization of future biomedical devices. This short review aims to highlight the influence of 2D material surfaces and the properties that arise due to their 2D structure. Using recent (within the last few years) examples of biosensors and biomedical applications, we emphasize the important role of 2D materials in advancing developments and research for biosensing and healthcare.
Collapse
Affiliation(s)
- Emily P Nguyen
- Nanobioelectronics & Biosensors Group, Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193, Barcelona, Spain.
| | - Cecilia de Carvalho Castro Silva
- Nanobioelectronics & Biosensors Group, Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193, Barcelona, Spain. and MackGraphe - Graphene and Nanomaterials Research Center, Mackenzie Presbyterian University, 01302-907, São Paulo, Brazil
| | - Arben Merkoçi
- Nanobioelectronics & Biosensors Group, Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193, Barcelona, Spain. and ICREA Institució Catalana de Recerca i Estudis Avançats, Barcelona 08010, Spain
| |
Collapse
|
9
|
Sha R, Bhattacharyya TK. MoS2-based nanosensors in biomedical and environmental monitoring applications. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.136370] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|