1
|
Zhao M, Yuan X, Wei L, Dai B, Zhuang S, Zhang D. Concentration Measurement with Ultrabroad Dynamic Range Using Few-Step Variable Optical-Path-Length Slope Method. Anal Chem 2025; 97:8774-8781. [PMID: 40193700 DOI: 10.1021/acs.analchem.4c06129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/09/2025]
Abstract
Concentration measurement has important applications in many fields, including pollution assessment in environmental science and drug dosage calculation in biomedical research. In the conventional methods, concentration is determined by measuring absorbance along a fixed long optical path. However, it is not suitable for high-concentration measurement. Herein, we have proposed a few-step variable optical-path-length slope method (fs-VOSM) for ultrabroad dynamic-range concentration measurement. As a proof of the method, we devised an fs-VOSM system in which a reference path is included to enhance the accuracy and repeatability. The measurement is conducted at 5 positions along ultrashort optical path (0-20 μm) for 800 ms. In the measurement of potassium dichromate solution concentration, the fs-VOSM system exhibits a wide dynamic range from 0.879 to 70.726 g/L with coefficient of variation (CV < 1.4%) and high accuracy (relative error within ±3.5%). We prospect that the fs-VOSM can be widely adopted in many advanced instruments such as process analyzer, flow injection analyzer, and turbidity meter.
Collapse
Affiliation(s)
- Mingwei Zhao
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, No. 516 Jungong Road, Yangpu District, Shanghai 200093, China
| | - Xujun Yuan
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, No. 516 Jungong Road, Yangpu District, Shanghai 200093, China
| | - Li Wei
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, No. 516 Jungong Road, Yangpu District, Shanghai 200093, China
| | - Bo Dai
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, No. 516 Jungong Road, Yangpu District, Shanghai 200093, China
| | - Songlin Zhuang
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, No. 516 Jungong Road, Yangpu District, Shanghai 200093, China
| | - Dawei Zhang
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, No. 516 Jungong Road, Yangpu District, Shanghai 200093, China
| |
Collapse
|
2
|
Qin L, Chen H, Nie Y, Zhou M, Huang J, Xiao Z. A Monoclonal Antibody-Based Time-Resolved Fluorescence Microsphere Lateral Flow Immunoassay for Dinotefuran and Clothianidin Detection. Foods 2025; 14:1174. [PMID: 40238351 PMCID: PMC11988585 DOI: 10.3390/foods14071174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2025] [Revised: 03/23/2025] [Accepted: 03/25/2025] [Indexed: 04/18/2025] Open
Abstract
Dinotefuran and clothianidin belong to the third generation of nicotinic insecticides and are widely used in crop pest control. It is necessary to detect their residues in food. The time-resolved fluorescent microspheres lateral flow immunoassay (TRFMs-LFIA) has the advantages of high sensitivity, short duration, and simple operation and is suitable for rapid field testing. In this study, two haptens (FCA-1, FCA-2) were synthesized in three steps and conjugated to the carrier proteins to obtain artificial antigens, which were subsequently used for monoclonal antibody preparation. A TRFMs-LFIA based on monoclonal antibodies was established to detect dinotefuran and clothianidin residues in food. The limit of detection (LOD) for dinotefuran was 0.045 ng/mL, with an IC50 of 0.61 ng/mL and a linear range (IC20~IC80) of 0.12~3.11 ng/mL. The LOD for clothianidin was 0.11 ng/mL, with an IC50 of 0.94 ng/mL and a linear range (IC20~IC80) of 0.24~3.65 ng/mL. Cross-reactivity rates with seven tested structural analogs were less than 1.5%. The pretreatment method was optimized for wheat, cucumber, and cabbage samples, which was time-saving (20 min) and easy to operate. The average recovery rates ranged from 88.0% to 114.8%, with the corresponding coefficients of variation appearing (CV) between 1.9% and 13.5%. The results of actual wheat, cucumber, and cabbage samples detected by the established TRFMs-LFIA were consistent with those of Ultra-Performance Liquid Chromatography coupled with Tandem Mass Spectrometry (UPLC-MS/MS). These results demonstrate that the established TRFMs-LFIA is sensitive, accurate, rapid, and suitable for real sample detection.
Collapse
Affiliation(s)
| | | | | | | | | | - Zhili Xiao
- Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China
| |
Collapse
|
3
|
Zhang Y, Kong X, Guo HY, Wang J, Yin ZZ. A mesothelin microsensor based on an embedded thionine electronic medium within an imprinted polymer on an acupuncture needle electrode. Analyst 2024; 149:3309-3316. [PMID: 38699925 DOI: 10.1039/d4an00490f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2024]
Abstract
An electrochemical microsensor for mesothelin (MSLN) based on an acupuncture needle (AN) was constructed in this work. To prepare the microsensor, MSLN was self-assembled on 4-mercaptophenylboronic acid (4-MPBA) by an interaction force between the external cis-diol and phenylboronic acid. This was followed by the gradual electropolymerization of thionine (TH) and eriochrome black T (EBT) around the anchored protein. The thickness of the surface imprinted layers influenced the sensing performance and needed to be smaller than the height of the anchored protein. The polymerized EBT was not electrically active, but the polymerized TH provided a significant electrochemical signal. Therefore, electron transfer smoothly proceeded through the eluted nanocavities. The imprinted nanocavities were highly selective toward MSLN, and the rebinding of insulating proteins reduced the electrochemical signal of the embedded pTH. The functionalized interface was characterized by SEM and electrochemical methods, and the preparation conditions were studied. After optimization, the sensor showed a linear response in the range of 0.1 to 1000 ng mL-1 with a detection limit of 10 pg mL-1, indicating good performance compared with other reported methods. This microsensor also showed high sensitivity and stability, which can be attributed to the fine complementation of the imprinted organic nanocavities. The sensitivity of this sensor was related to the nanocavities used for electron transport around the AuNPs. In the future, microsensors that can directly provide electrochemical signals are expected to play important roles especially on AN matrices.
Collapse
Affiliation(s)
- Yi Zhang
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China.
- College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, China.
- Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001. China
| | - Xue Kong
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China.
- College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, China.
| | - Hai-Yang Guo
- College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, China.
| | - Jing Wang
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China.
| | - Zheng-Zhi Yin
- College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, China.
- Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001. China
| |
Collapse
|
4
|
Cheng HP, Yang TH, Wang JC, Chuang HS. Recent Trends and Innovations in Bead-Based Biosensors for Cancer Detection. SENSORS (BASEL, SWITZERLAND) 2024; 24:2904. [PMID: 38733011 PMCID: PMC11086254 DOI: 10.3390/s24092904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Revised: 04/29/2024] [Accepted: 04/30/2024] [Indexed: 05/13/2024]
Abstract
Demand is strong for sensitive, reliable, and cost-effective diagnostic tools for cancer detection. Accordingly, bead-based biosensors have emerged in recent years as promising diagnostic platforms based on wide-ranging cancer biomarkers owing to the versatility, high sensitivity, and flexibility to perform the multiplexing of beads. This comprehensive review highlights recent trends and innovations in the development of bead-based biosensors for cancer-biomarker detection. We introduce various types of bead-based biosensors such as optical, electrochemical, and magnetic biosensors, along with their respective advantages and limitations. Moreover, the review summarizes the latest advancements, including fabrication techniques, signal-amplification strategies, and integration with microfluidics and nanotechnology. Additionally, the challenges and future perspectives in the field of bead-based biosensors for cancer-biomarker detection are discussed. Understanding these innovations in bead-based biosensors can greatly contribute to improvements in cancer diagnostics, thereby facilitating early detection and personalized treatments.
Collapse
Affiliation(s)
- Hui-Pin Cheng
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan (T.-H.Y.)
| | - Tai-Hua Yang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan (T.-H.Y.)
- Department of Orthopedic Surgery, National Cheng Kung University Hospital, Tainan 704, Taiwan
- Medical Device Innovation Center, National Cheng Kung University, Tainan 701, Taiwan
| | - Jhih-Cheng Wang
- Department of Urology, Chimei Medical Center, Tainan 710, Taiwan
- Department of Electrical Engineering, Southern Taiwan University of Science and Technology, Tainan 710, Taiwan
- School of Medicine, College of Medicine, National Sun Yat-sen University, Kaohsiung 804, Taiwan
| | - Han-Sheng Chuang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan (T.-H.Y.)
- Medical Device Innovation Center, National Cheng Kung University, Tainan 701, Taiwan
| |
Collapse
|
5
|
Yin B, Wan X, Yue W, Zhou T, Shi L, Wang S, Lin X. A portable automated chip for simultaneous rapid point-of-care testing of multiple β-agonists. Biosens Bioelectron 2023; 239:115586. [PMID: 37603988 DOI: 10.1016/j.bios.2023.115586] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 08/07/2023] [Accepted: 08/08/2023] [Indexed: 08/23/2023]
Abstract
Abusive use of β-agonists as feed additives for animals and medication is detrimental to human health and food safety. Conventional assays are restricted to a single type of β-agonists detection and cannot match the multiplexing features to perform automated, high throughput, and rapid quantitative analysis in real samples. In this research, we develop a portable automated chip system (PACS) with highly integrated automated devices in conjunction with portable microfluidic chips to provide simultaneous point-of-care testing of multiple β-agonists in the field, simplifying complex manual methods, shortening assay times, and improving sensitivity. Specifically, silicon film is used as reaction substrates for immobilizing the conjugates of β-agonists to increase the sensitivity of the assay result. Then, the PACS with a chemiluminescence imaging detector is established for automatic high-throughput and sensitive detection of Clenbuterol, Ractopamine, and Salbutamol based on the indirect immunoassay. Newly developed chip with high mixing performance can improve the sensitivity of target determination. Multiplex assays were carried out using the developed system for Clenbuterol, Ractopamine, and Salbutamol with a limit of detection of 54 pg mL-1,59 pg mL-1, and 93 pg mL-1, respectively. Except for sample preparation and coating, the detection in the PACS takes less than 47 min. A satisfactory sample recovery (86.33%-108.12%) was obtained, validating the reliability and practical applicability of this PACS. Meanwhile, the PACS enables sensitive and rapid detection of multiple β-agonists in farms or markets where lacking advanced laboratory facilities.
Collapse
Affiliation(s)
- Binfeng Yin
- School of Mechanical Engineering, Yangzhou University, Yangzhou, 225127, China.
| | - Xinhua Wan
- School of Mechanical Engineering, Yangzhou University, Yangzhou, 225127, China
| | - Wenkai Yue
- School of Mechanical Engineering, Yangzhou University, Yangzhou, 225127, China
| | - Teng Zhou
- Mechanical and Electrical Engineering College, Hainan University, Haikou, 570228, China
| | - Liuyong Shi
- Mechanical and Electrical Engineering College, Hainan University, Haikou, 570228, China
| | - Songbai Wang
- School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, 030006, China.
| | - Xiaodong Lin
- Zhuhai UM Science & Technology Research Institute, Zhuhai, 519000, China.
| |
Collapse
|
6
|
García-Hernández LA, Martínez-Martínez E, Pazos-Solís D, Aguado-Preciado J, Dutt A, Chávez-Ramírez AU, Korgel B, Sharma A, Oza G. Optical Detection of Cancer Cells Using Lab-on-a-Chip. BIOSENSORS 2023; 13:bios13040439. [PMID: 37185514 PMCID: PMC10136345 DOI: 10.3390/bios13040439] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/23/2023] [Accepted: 03/28/2023] [Indexed: 05/17/2023]
Abstract
The global need for accurate and efficient cancer cell detection in biomedicine and clinical diagnosis has driven extensive research and technological development in the field. Precision, high-throughput, non-invasive separation, detection, and classification of individual cells are critical requirements for successful technology. Lab-on-a-chip devices offer enormous potential for solving biological and medical problems and have become a priority research area for microanalysis and manipulating cells. This paper reviews recent developments in the detection of cancer cells using the microfluidics-based lab-on-a-chip method, focusing on describing and explaining techniques that use optical phenomena and a plethora of probes for sensing, amplification, and immobilization. The paper describes how optics are applied in each experimental method, highlighting their advantages and disadvantages. The discussion includes a summary of current challenges and prospects for cancer diagnosis.
Collapse
Affiliation(s)
- Luis Abraham García-Hernández
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Parque Tecnológico Querétaro, Pedro Escobedo, Querétaro C.P. 76703, Mexico
| | | | - Denni Pazos-Solís
- Tecnologico de Monterrey, School of Engineering and Sciences, Centre of Bioengineering, Campus Queretaro, Querétaro C.P. 76130, Mexico
| | - Javier Aguado-Preciado
- Tecnologico de Monterrey, School of Engineering and Sciences, Centre of Bioengineering, Campus Queretaro, Querétaro C.P. 76130, Mexico
| | - Ateet Dutt
- Instituto de Investigaciones en Materiales, Circuito Exterior S/N Ciudad Universitaria, Mexico City C.P. 04510, Mexico
| | - Abraham Ulises Chávez-Ramírez
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Parque Tecnológico Querétaro, Pedro Escobedo, Querétaro C.P. 76703, Mexico
| | - Brian Korgel
- McKetta Department of Chemical Engineering and Texas Materials Institute, The University of Texas at Austin, Austin, TX 78712-1062, USA
| | - Ashutosh Sharma
- Tecnologico de Monterrey, School of Engineering and Sciences, Centre of Bioengineering, Campus Queretaro, Querétaro C.P. 76130, Mexico
| | - Goldie Oza
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Parque Tecnológico Querétaro, Pedro Escobedo, Querétaro C.P. 76703, Mexico
| |
Collapse
|
7
|
Lu L, Zhang H, Wang Y, Zhang P, Zhu Z, Yang C. Dissolution-Enhanced Luminescence Enhanced Digital Microfluidics Immunoassay for Sensitive and Automated Detection of H5N1. ACS APPLIED MATERIALS & INTERFACES 2023; 15:6526-6535. [PMID: 36708351 DOI: 10.1021/acsami.2c20289] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Protein bioassay is a critical tool for the screening and detection of protein biomarkers in disease diagnostics and biological applications. However, the detection sensitivity and system automation of current immunoassays do not meet the emerging demands of clinical applications. Here, we developed a dissolution-enhanced luminescence-enhanced digital microfluidics immunoassay (DEL-DMF), which significantly improves the sensitivity and automation of the protein bioassay. In DEL-DMF, the sample and reagent droplets are controlled to complete the processes of sample transport, immunoreaction, and buffer washing, which not only minimizes sample consumption to 2 μL and enhances the binding efficiency of immunoreaction but also streamlines all the procedures and simplifies the process of immunoassay. Moreover, dissolution-enhanced luminescence using NaEuF4 NPs as nanoprobes boosts the fluorescence and increases the sensitivity of the bioassay. We demonstrate the enhanced analytical performance of our DEL-DMF immunoassay to detect H5N1 hemagglutinin in human serum and saliva. A limit of detection of 1.16 pM was achieved in less than 0.5 h with only 2 μL sample consumption. Overall, our DEL-DMF immunoassay combines the merits of the microfluidics platform and dissolution-enhanced luminescence, thus affording superior detection sensitivity and system automation for protein biomarkers. This novel immunoassay microsystem holds great potential in clinical and biological applications.
Collapse
Affiliation(s)
- Lianyu Lu
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, the Key Laboratory of Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, Department of Chemistry, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Huimin Zhang
- Innovation Laboratory for Sciences and Technologies of Energy Materials of Fujian Province (IKKEM), Xiamen 361005, China
| | - Yang Wang
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, the Key Laboratory of Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, Department of Chemistry, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Peng Zhang
- Institute of Molecular Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China
| | - Zhi Zhu
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, the Key Laboratory of Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, Department of Chemistry, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Chaoyong Yang
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, the Key Laboratory of Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, Department of Chemistry, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
- Innovation Laboratory for Sciences and Technologies of Energy Materials of Fujian Province (IKKEM), Xiamen 361005, China
- Institute of Molecular Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China
| |
Collapse
|
8
|
Wu K, He X, Wang J, Pan T, He R, Kong F, Cao Z, Ju F, Huang Z, Nie L. Recent progress of microfluidic chips in immunoassay. Front Bioeng Biotechnol 2022; 10:1112327. [PMID: 36619380 PMCID: PMC9816574 DOI: 10.3389/fbioe.2022.1112327] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Accepted: 12/08/2022] [Indexed: 12/24/2022] Open
Abstract
Microfluidic chip technology is a technology platform that integrates basic operation units such as processing, separation, reaction and detection into microchannel chip to realize low consumption, fast and efficient analysis of samples. It has the characteristics of small volume need of samples and reagents, fast analysis, low cost, automation, portability, high throughout, and good compatibility with other techniques. In this review, the concept, preparation materials and fabrication technology of microfluidic chip are described. The applications of microfluidic chip in immunoassay, including fluorescent, chemiluminescent, surface-enhanced Raman spectroscopy (SERS), and electrochemical immunoassay are reviewed. Look into the future, the development of microfluidic chips lies in point-of-care testing and high throughput equipment, and there are still some challenges in the design and the integration of microfluidic chips, as well as the analysis of actual sample by microfluidic chips.
Collapse
Affiliation(s)
- Kaimin Wu
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Xuliang He
- Zhuzhou People's Hospital, Zhuzhou, China
| | - Jinglei Wang
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Ting Pan
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Ran He
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Feizhi Kong
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Zhenmin Cao
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Feiye Ju
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Zhao Huang
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Libo Nie
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| |
Collapse
|
9
|
Piorino F, Patterson AT, Styczynski MP. Low-cost, point-of-care biomarker quantification. Curr Opin Biotechnol 2022; 76:102738. [PMID: 35679813 PMCID: PMC9807261 DOI: 10.1016/j.copbio.2022.102738] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 04/24/2022] [Accepted: 04/27/2022] [Indexed: 01/04/2023]
Abstract
Low-cost, point-of-care (POC) devices that allow fast, on-site disease diagnosis could have a major global health impact, particularly if they can provide quantitative measurement of molecules indicative of a diseased state (biomarkers). Accurate quantification of biomarkers in patient samples is already challenging when research-grade, sophisticated equipment is available; it is even more difficult when constrained to simple, cost-effective POC platforms. Here, we summarize the main challenges to accurate, low-cost POC biomarker quantification. We also review recent efforts to develop and implement POC tools beyond qualitative readouts, and we conclude by identifying important future research directions.
Collapse
Affiliation(s)
- Fernanda Piorino
- School of Chemical & Biomolecular Engineering, Georgia Institute of Technology, 311 Ferst Drive NW, Atlanta, GA 30332-0100, United States
| | - Alexandra T Patterson
- School of Chemical & Biomolecular Engineering, Georgia Institute of Technology, 311 Ferst Drive NW, Atlanta, GA 30332-0100, United States
| | - Mark P Styczynski
- School of Chemical & Biomolecular Engineering, Georgia Institute of Technology, 311 Ferst Drive NW, Atlanta, GA 30332-0100, United States.
| |
Collapse
|
10
|
Weidemann S, Perez D, Izbicki JR, Neipp M, Mofid H, Daniels T, Nahrstedt U, Jacobsen F, Bernreuther C, Simon R, Steurer S, Burandt E, Marx AH, Krech T, Clauditz TS, Jansen K. Mesothelin is Commonly Expressed in Pancreatic Adenocarcinoma but Unrelated to Cancer Aggressiveness. Cancer Invest 2021; 39:711-720. [PMID: 34143695 DOI: 10.1080/07357907.2021.1943747] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Data on Mesothelin (MSLN) expression in human normal and cancerous tissues is controversial. We employed immunohistochemistry (IHC) on a tissue microarray (TMA) from 599 pancreatic cancers and 12 large tissue sections of pancreatitis. MSLN expression was highest in pancreatic adenocarcinomas (89%) and adenocarcinomas of the ampulla Vateri (79%), infrequent in pancreatitis and absent in 6 acinus cell carcinomas and normal pancreas. MSLN expression was unrelated to pathological tumor stage, grade, metastasis, and tumor-infiltrating CD8+ lymphocytes. In conclusion, pancreatic cancer may be ideally suited for putative anti- MSLN therapies, and MSLN may represent a suitable biomarker for pancreatic cancer diagnosis, especially on small biopsies.
Collapse
Affiliation(s)
- Sören Weidemann
- Institute of Pathology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Daniel Perez
- General, Visceral and Thoracic Surgery Department and Clinic, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Jakob R Izbicki
- General, Visceral and Thoracic Surgery Department and Clinic, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Michael Neipp
- General, Vascular and Visceral Surgery Clinic, Itzehoe Medical Center, Itzehoe, Germany
| | - Hamid Mofid
- General, Visceral Thoracic and Vascular Surgery Clinic, Regio Clinic Pinneberg, Pinneberg, Germany
| | - Thies Daniels
- General, Visceral and Tumor Surgery Clinic, Albertinen Hospital, Hamburg, Germany
| | - Ulf Nahrstedt
- Department of General and Abdominal Surgery, Schoen Clinic Hamburg Eilbek, Hamburg, Germany
| | - Frank Jacobsen
- Institute of Pathology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Christian Bernreuther
- Institute of Pathology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Ronald Simon
- Institute of Pathology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Stefan Steurer
- Institute of Pathology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Eike Burandt
- Institute of Pathology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Andreas H Marx
- Institute of Pathology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Department of Pathology, Academic Hospital Fuerth, Fuerth, Germany
| | - Till Krech
- Institute of Pathology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Institute of Pathology, Clinical Center Osnabrueck, Osnabrueck, Germany
| | - Till S Clauditz
- Institute of Pathology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Kristina Jansen
- General, Visceral and Thoracic Surgery Department and Clinic, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
11
|
Silva MLS. Microfluidic devices for glycobiomarker detection in cancer. Clin Chim Acta 2021; 521:229-243. [PMID: 34273337 DOI: 10.1016/j.cca.2021.07.013] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 07/07/2021] [Accepted: 07/12/2021] [Indexed: 12/20/2022]
Abstract
During oncogenesis, several alterations occur within cells, one of them being the abnormal glycosylation of proteins, resulting in the formation of glycoproteins with aberrant glycan structures, which can be secreted into the blood stream. Their specific association to tumour cells makes them useful indicators (biomarkers) of the oncogenic process and their detection in blood can be employed in different stages of tumour development for early detection, prognosis and therapeutic drug monitoring. Due to the importance of detecting cancer-associated glycoproteins with aberrant glycosylation in blood or serum, analytical methodologies with improved performance are required to ameliorate the laboratorial tests currently used for the detection of these analytes. Microfluidics was created to facilitate the implementation of simple and point-of-care analysis, away from a centralized laboratory. The massive use of microfluidic systems in clinical settings can be seen in pregnancy tests and diabetes control, for example. But what about other clinical domains, such as the detection of glycoproteins with aberrant glycans secreted by tumour cells? Are microfluidic systems helpful in this case? This review analyses the requirements of a microfluidic assay for the detection of low-abundant blood/serum cancer-associated glycoproteins with abnormal glycans and the progresses that have been made in the last years to develop integrated microfluidic devices for this particular application. The diverse microfluidic systems found in literature present, in general, the same analytical performance as the conventional assays but have additional advantages, namely a reduction in assay times, a decrease of sample and reagent consumption and lower costs. The review will also focus on the improvements that are still needed for better biosensing of this type of cancer biomarkers using microfluidic devices.
Collapse
Affiliation(s)
- M Luísa S Silva
- Centre of Chemical Research, Autonomous University of Hidalgo State, Carr. Pachuca-Tulancingo km 4.5, Pachuca, Hidalgo 42076, Mexico.
| |
Collapse
|
12
|
Duan X, Zhang X, Chen J, Xiao M, Zhao W, Liu S, Sui G. Association of PM 2.5 with Insulin Resistance Signaling Pathways on a Microfluidic Liver-Kidney Microphysiological System (LK-MPS) Device. Anal Chem 2021; 93:9835-9844. [PMID: 34232631 DOI: 10.1021/acs.analchem.1c01384] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Insulin resistance (IR) is a typical sign of metabolic dysregulation caused by fine particulate matter (PM2.5), but the underlying signaling has not been clearly determined. Herein, a microfluidic liver-kidney microphysiological system (LK-MPS) is presented to assess the signaling pathways of IR generated by PM2.5 at 200 μg/mL for 24 h. The LK-MPS device consisted of a biomimetic liver-kidney architecture and reconstructed two circulation paths: the liver metabolism-kidney excretion (LM-KE) and kidney excretion-liver metabolism (KE-LM), by which PM2.5 is feasibly distributed in the two organs. Transmission electron microscopy (TEM) analysis revealed that PM2.5 can embed in the cytoplasm and nuclei, undergo transport by vesicles, and lead to the destruction of mitochondria. Further comprehensive immunofluorescence, enzyme-linked immunosorbent assays (ELISAs) and untargeted metabolomic analyses confirmed that PM2.5 disturbed the classic IRS-1/AKT signaling pathway (INSR, IRS-1, PI3K, AKT, GLUT2, GLUT4, and FOXO1 downregulated) and IR-related metabolic pathways: UDP-hexosamine (UDP-GlcNAc), gluconeogenesis (β-d-glucose 6-phosphate), and lipid biosynthesis (ceramide (Cer) and triacylglycerol (TG)) pathways, leading to the disorder of glucose levels. Collectively, these disorders aggravate hepatic and renal IR. Pearson's correlation coefficient test showed that elemental carbon (EC), polycyclic aromatic hydrocarbons (PAHs), and metals (Ca, Co, and V) were negatively correlated to the dysregulated proteins (INSR, IRS-1, AKT, FOXO1, GLUT2, and GLUT4). These findings may partially explain IR-related signaling pathways triggered by PM2.5.
Collapse
Affiliation(s)
- Xiaoxiao Duan
- Shanghai Key Laboratory of Atmospheric Particle Pollution Prevention (LAP3), Department of Environmental Science & Engineering, Fudan University, 2005 Songhu Road, Shanghai 200438, P. R. China
| | - Xinlian Zhang
- Shanghai Key Laboratory of Atmospheric Particle Pollution Prevention (LAP3), Department of Environmental Science & Engineering, Fudan University, 2005 Songhu Road, Shanghai 200438, P. R. China
| | - Jianmin Chen
- Shanghai Key Laboratory of Atmospheric Particle Pollution Prevention (LAP3), Department of Environmental Science & Engineering, Fudan University, 2005 Songhu Road, Shanghai 200438, P. R. China
| | - Mingming Xiao
- Shanghai Key Laboratory of Atmospheric Particle Pollution Prevention (LAP3), Department of Environmental Science & Engineering, Fudan University, 2005 Songhu Road, Shanghai 200438, P. R. China
| | - Wang Zhao
- Shanghai Key Laboratory of Atmospheric Particle Pollution Prevention (LAP3), Department of Environmental Science & Engineering, Fudan University, 2005 Songhu Road, Shanghai 200438, P. R. China
| | - Sixiu Liu
- Shanghai Key Laboratory of Atmospheric Particle Pollution Prevention (LAP3), Department of Environmental Science & Engineering, Fudan University, 2005 Songhu Road, Shanghai 200438, P. R. China
| | - Guodong Sui
- Shanghai Key Laboratory of Atmospheric Particle Pollution Prevention (LAP3), Department of Environmental Science & Engineering, Fudan University, 2005 Songhu Road, Shanghai 200438, P. R. China
| |
Collapse
|
13
|
Pinto IF, Soares RRG, Mäkinen MEL, Chotteau V, Russom A. Multiplexed Microfluidic Cartridge for At-Line Protein Monitoring in Mammalian Cell Culture Processes for Biopharmaceutical Production. ACS Sens 2021; 6:842-851. [PMID: 33724791 PMCID: PMC8034812 DOI: 10.1021/acssensors.0c01884] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
![]()
The biopharmaceutical
market has been rapidly growing in recent
years, creating a highly competitive arena where R&D is critical
to strike a balance between clinical safety and profitability. Toward
process optimization, the recent development and adoption of new process
analytical technologies (PAT) highlight the dynamic complexity of
mammalian/human cell culture processes, as well as the importance
of fine-tuning and modeling key metabolites and proteins. In this
context, simple, rapid, and cost-effective devices allowing routine
at-line monitoring of specific proteins during process development
and production are currently lacking. Here, we report the development
of a versatile microfluidic protein analysis cartridge allowing the
multiplexed bead-based immunodetection of specific proteins directly
from complex mixtures with minimal hands-on time. Colorimetric quantification
of Chinese hamster ovary (CHO) host cell proteins as key impurities,
monoclonal antibodies as target biopharmaceuticals, and lactate dehydrogenase
as a marker of cell viability was achieved with limits of detection
in the 1–10 ng/mL range and analysis times as short as 30 min.
The device was further demonstrated for the monitoring of a Rituximab-producing
CHO cell bioreactor over the course of 8 days, providing comparable
recoveries to standard enzyme-linked immunosorbent assay (ELISA) kits.
The high sensitivity combined with robustness to matrix interference
highlights the potential of the device to perform at-line measurements
spanning from the bioreactor to the downstream processing.
Collapse
Affiliation(s)
- Inês F. Pinto
- KTH Royal Institute of Technology, Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, 171 21 Solna, Sweden
| | - Ruben R. G. Soares
- KTH Royal Institute of Technology, Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, 171 21 Solna, Sweden
| | - Meeri E.-L. Mäkinen
- KTH Royal Institute of Technology, Department of Industrial Biotechnology, School of Engineering Sciences in Chemistry, Biotechnology and Health, 106 91 Stockholm, Sweden
- AdBIOPRO, Competence Centre for Advanced BioProduction by Continuous Processing, KTH, 100 44 Stockholm, Sweden
| | - Veronique Chotteau
- KTH Royal Institute of Technology, Department of Industrial Biotechnology, School of Engineering Sciences in Chemistry, Biotechnology and Health, 106 91 Stockholm, Sweden
- AdBIOPRO, Competence Centre for Advanced BioProduction by Continuous Processing, KTH, 100 44 Stockholm, Sweden
| | - Aman Russom
- KTH Royal Institute of Technology, Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, 171 21 Solna, Sweden
- AIMES, Center for the Advancement of Integrated Medical and Engineering Sciences at Karolinska Institutet and KTH Royal Institute of Technology, 100 44 Stockholm, Sweden
| |
Collapse
|
14
|
Kaewjua K, Nakthong P, Chailapakul O, Siangproh W. Flow-based System: A Highly Efficient Tool Speeds Up Data Production and Improves Analytical Performance. ANAL SCI 2021; 37:79-92. [PMID: 32981899 DOI: 10.2116/analsci.20sar02] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
In this review, we cite references from the period between 2015 and 2020 related to the use of a flow-based system as a tool to obtain a modern analytical system for speeding up data production and improving performance. Based on a great deal of concepts for automatic systems, there are several research groups introduced in the development of flow-based systems to increase sample throughput while retaining the reproducibility and repeatability as well as to propose new platforms of flow-based systems, such as microfluidic chip and paper-based devices. Additionally, to apply a developed system for on-site analysis is one of the key features for development. We believe that this review will be very interested and useful for readers because of its impact on developing novel analytical systems. The content of the review is categorized following their applications including quality control and food safety, clinical diagnostics, environmental monitoring and miscellaneous.
Collapse
Affiliation(s)
- Kantima Kaewjua
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand
| | - Prangthip Nakthong
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand
| | - Orawon Chailapakul
- Electrochemistry and Optical Spectroscopy Center of Excellence, Department of Chemistry, Faculty of Science, Bangkok, 10330, Thailand
| | - Weena Siangproh
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand.
| |
Collapse
|