1
|
Li Y, Wang X, Chen Y, Yang Z, Jiang ZX. Monodisperse polyethylene glycol "brushes" with enhanced lipophilicity, and thermo and plasma stability. Chem Commun (Camb) 2019; 55:1895-1898. [PMID: 30667418 DOI: 10.1039/c8cc09151j] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
A convenient strategy was developed for highly branched and multifunctionalized peptidic monodisperse polyethylene glycol "brushes", which exhibit remarkable physicochemical and biological properties and potential as versatile biomaterials.
Collapse
Affiliation(s)
- Yu Li
- Hubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticals, School of Pharmaceutical Sciences, Wuhan University, Wuhan 430071, China.
| | | | | | | | | |
Collapse
|
2
|
Schibrowski ML, Barnes TS, Wawegama NK, Vance ME, Markham PF, Mansell PD, Marenda MS, Kanci A, Perez-Casal J, Browning GF, Gibson JS, Mahony TJ. The Performance of Three Immune Assays to Assess the Serological Status of Cattle Experimentally Exposed to Mycoplasma bovis. Vet Sci 2018. [PMID: 29518043 PMCID: PMC5876582 DOI: 10.3390/vetsci5010027] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Mycoplasma bovis is associated with several clinical syndromes of cattle. Currently, limited information is available on the sensitivity (Se) and specificity (Sp) of serological assays used for the detection of M. bovis-specific antibodies. Consequently, it is difficult to critically evaluate the outcomes of studies that use these assays. Therefore, the current study used bovine sera sourced from M. bovis exposure studies from three countries to estimate the Se and Sp of two commercial M. bovis enzyme-linked immunosorbent assays (ELISA), BIO K302 and BIO K260, and Western blotting. Western blotting had the highest Se estimate of 74% (95% confidence interval (CI): 16–98%), compared to the BIO K302: 47% (95% CI: 10–87%) and BIO K260: 28% (95% CI: 1–92%). However, for Sp, the BIO K302: 96% (95% CI: 87–99%) and the BIO K260: 100% (95% CI: 93–100%) out-performed Western blotting: 88% (95% CI: 56–98%). Western blotting was the best assay for detecting seroconversion, correctly identifying 61% (95% CI: 29–86%) of exposed animals compared to 35% for BIO K302 (95% CI: 21–54%) and 8% for BIO K260 (95% CI: 0–87%). While none of the methods assessed had high Se and Sp, the availability of these estimates will aid in the interpretation of studies that use these assays. The results of this study highlight the difficulties encountered when using serology to detect exposure to M. bovis in cattle.
Collapse
Affiliation(s)
- Meghan L Schibrowski
- Queensland Alliance for Agriculture and Food Innovation, The University of Queensland, St Lucia, QLD 4072, Australia.
| | - Tamsin S Barnes
- Queensland Alliance for Agriculture and Food Innovation, The University of Queensland, St Lucia, QLD 4072, Australia.
- School of Veterinary Science, The University of Queensland, Gatton, QLD 4343, Australia.
| | - Nadeeka K Wawegama
- Asia-Pacific Centre for Animal Health, Faculty of Veterinary and Agricultural Sciences, The University of Melbourne, Parkville, VIC 3010, Australia.
| | - Megan E Vance
- Queensland Alliance for Agriculture and Food Innovation, The University of Queensland, St Lucia, QLD 4072, Australia.
| | - Philip F Markham
- Asia-Pacific Centre for Animal Health, Faculty of Veterinary and Agricultural Sciences, The University of Melbourne, Parkville, VIC 3010, Australia.
| | - Peter D Mansell
- Asia-Pacific Centre for Animal Health, Faculty of Veterinary and Agricultural Sciences, The University of Melbourne, Parkville, VIC 3010, Australia.
| | - Marc S Marenda
- Asia-Pacific Centre for Animal Health, Faculty of Veterinary and Agricultural Sciences, The University of Melbourne, Parkville, VIC 3010, Australia.
| | - Anna Kanci
- Asia-Pacific Centre for Animal Health, Faculty of Veterinary and Agricultural Sciences, The University of Melbourne, Parkville, VIC 3010, Australia.
| | - José Perez-Casal
- Vaccine and Infectious Disease Organization-International Vaccine Centre (VIDO-InterVac), 120 Veterinary Road, Saskatoon, SK S7N 5E3, Canada.
| | - Glenn F Browning
- Asia-Pacific Centre for Animal Health, Faculty of Veterinary and Agricultural Sciences, The University of Melbourne, Parkville, VIC 3010, Australia.
| | - Justine S Gibson
- School of Veterinary Science, The University of Queensland, Gatton, QLD 4343, Australia.
| | - Timothy J Mahony
- Queensland Alliance for Agriculture and Food Innovation, The University of Queensland, St Lucia, QLD 4072, Australia.
| |
Collapse
|
3
|
Istivan SB, Bishop DK, Jones AL, Grosser ST, Schneider JW. A 502-Base Free-Solution Electrophoretic DNA Sequencing Method Using End-Attached Wormlike Micelles. Anal Chem 2015; 87:11433-40. [PMID: 26455271 DOI: 10.1021/acs.analchem.5b02931] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We demonstrate that the use of wormlike nonionic micelles as drag-tags in end-labeled free-solution electrophoresis ("micelle-ELFSE") provides single-base resolution of Sanger sequencing products up to 502 bases in length, a nearly 2-fold improvement over reported ELFSE separations. "CiEj" running buffers containing 48 mM C12E5, 6 mM C10E5, and 3 M urea (32.5 °C) form wormlike micelles that provide a drag equivalent to an uncharged DNA fragment with a length (α) of 509 bases (effective Rh = 27 nm). Runtime in a 40 cm capillary (30 kV) was 35 min for elution of all products down to the 26-base primer. We also show that smaller Triton X-100 micelles give a read length of 103 bases in a 4 min run, so that a combined analysis of the Sanger products using the two buffers in separate capillaries could be completed in 14 min for the full range of lengths. A van Deemter analysis shows that resolution is limited by diffusion-based peak broadening and wall adsorption. Effects of drag-tag polydispersity are not observed, despite the inherent polydispersity of the wormlike micelles. We ascribe this to a stochastic size-sampling process that occurs as micelle size fluctuates rapidly during the runtime. A theoretical model of the process suggests that fluctuations occur with a time scale less than 10 ms, consistent with the monomer exchange process in nonionic micelles. The CiEj buffer has a low viscosity (2.7 cP) and appears to be semidilute in micelle concentration. The large drag-tag size of the CiEj buffers leads to steric segregation of the DNA and tag for short fragments and attendant mobility shifts.
Collapse
Affiliation(s)
- Stephen B Istivan
- Department of Chemical Engineering and ‡Department of Biomedical Engineering, Carnegie Mellon University , Pittsburgh, Pennsylvania 15213, United States
| | - Daniel K Bishop
- Department of Chemical Engineering and ‡Department of Biomedical Engineering, Carnegie Mellon University , Pittsburgh, Pennsylvania 15213, United States
| | - Angela L Jones
- Department of Chemical Engineering and ‡Department of Biomedical Engineering, Carnegie Mellon University , Pittsburgh, Pennsylvania 15213, United States
| | - Shane T Grosser
- Department of Chemical Engineering and ‡Department of Biomedical Engineering, Carnegie Mellon University , Pittsburgh, Pennsylvania 15213, United States
| | - James W Schneider
- Department of Chemical Engineering and ‡Department of Biomedical Engineering, Carnegie Mellon University , Pittsburgh, Pennsylvania 15213, United States
| |
Collapse
|
4
|
Durney BC, Crihfield CL, Holland LA. Capillary electrophoresis applied to DNA: determining and harnessing sequence and structure to advance bioanalyses (2009-2014). Anal Bioanal Chem 2015; 407:6923-38. [PMID: 25935677 PMCID: PMC4551542 DOI: 10.1007/s00216-015-8703-5] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2015] [Revised: 04/09/2015] [Accepted: 04/13/2015] [Indexed: 12/17/2022]
Abstract
This review of capillary electrophoresis methods for DNA analyses covers critical advances from 2009 to 2014, referencing 184 citations. Separation mechanisms based on free-zone capillary electrophoresis, Ogston sieving, and reptation are described. Two prevalent gel matrices for gel-facilitated sieving, which are linear polyacrylamide and polydimethylacrylamide, are compared in terms of performance, cost, viscosity, and passivation of electroosmotic flow. The role of capillary electrophoresis in the discovery, design, and characterization of DNA aptamers for molecular recognition is discussed. Expanding and emerging techniques in the field are also highlighted.
Collapse
Affiliation(s)
- Brandon C Durney
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, 26506, USA
| | | | | |
Collapse
|
5
|
Chung M, Kim D, Herr AE. Polymer sieving matrices in microanalytical electrophoresis. Analyst 2014; 139:5635-54. [DOI: 10.1039/c4an01179a] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
6
|
Dorfman KD, King SB, Olson DW, Thomas JDP, Tree DR. Beyond gel electrophoresis: microfluidic separations, fluorescence burst analysis, and DNA stretching. Chem Rev 2013; 113:2584-667. [PMID: 23140825 PMCID: PMC3595390 DOI: 10.1021/cr3002142] [Citation(s) in RCA: 141] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Kevin D. Dorfman
- Department of Chemical Engineering and Materials Science, University of Minnesota — Twin Cities, 421 Washington Ave. SE, Minneapolis, MN 55455, Phone: 1-612-624-5560. Fax: 1-612-626-7246
| | - Scott B. King
- Department of Chemical Engineering and Materials Science, University of Minnesota — Twin Cities, 421 Washington Ave. SE, Minneapolis, MN 55455, Phone: 1-612-624-5560. Fax: 1-612-626-7246
| | - Daniel W. Olson
- Department of Chemical Engineering and Materials Science, University of Minnesota — Twin Cities, 421 Washington Ave. SE, Minneapolis, MN 55455, Phone: 1-612-624-5560. Fax: 1-612-626-7246
| | - Joel D. P. Thomas
- Department of Chemical Engineering and Materials Science, University of Minnesota — Twin Cities, 421 Washington Ave. SE, Minneapolis, MN 55455, Phone: 1-612-624-5560. Fax: 1-612-626-7246
| | - Douglas R. Tree
- Department of Chemical Engineering and Materials Science, University of Minnesota — Twin Cities, 421 Washington Ave. SE, Minneapolis, MN 55455, Phone: 1-612-624-5560. Fax: 1-612-626-7246
| |
Collapse
|
7
|
Albrecht JC, Kotani A, Lin JS, Soper SA, Barron AE. Simultaneous detection of 19 K-ras mutations by free-solution conjugate electrophoresis of ligase detection reaction products on glass microchips. Electrophoresis 2013; 34:590-7. [PMID: 23192597 PMCID: PMC4361093 DOI: 10.1002/elps.201200462] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2012] [Revised: 10/19/2012] [Accepted: 10/23/2012] [Indexed: 01/08/2023]
Abstract
We demonstrate here the power and flexibility of free-solution conjugate electrophoresis (FSCE) as a method of separating DNA fragments by electrophoresis with no sieving polymer network. Previous work introduced the coupling of FSCE with ligase detection reaction (LDR) to detect point mutations, even at low abundance compared to the wild-type DNA. Here, four large drag-tags are used to achieve free-solution electrophoretic separation of 19 LDR products ranging in size from 42 to 66 nt that correspond to mutations in the K-ras oncogene. LDR-FSCE enabled electrophoretic resolution of these 19 LDR-FSCE products by CE in 13.5 min (E = 310 V/cm) and by microchip electrophoresis in 140 s (E = 350 V/cm). The power of FSCE is demonstrated in the unique characteristic of free-solution separations where the separation resolution is constant no matter the electric field strength. By microchip electrophoresis, the electric field was increased to the maximum of the power supply (E = 700 V/cm), and the 19 LDR-FSCE products were separated in less than 70 s with almost identical resolution to the separation at E = 350 V/cm. These results will aid the goal of screening K-ras mutations on integrated "sample-in/answer-out" devices with amplification, LDR, and detection all on one platform.
Collapse
Affiliation(s)
| | - Akira Kotani
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana, USA
- School of Pharmacy, Tokyo University of Pharmacy and Life Sciences, Tokyo, Japan
| | - Jennifer S. Lin
- Department of Bioengineering, Stanford University, Stanford, California, USA
| | - Steven A. Soper
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana, USA
| | - Annelise E. Barron
- Department of Bioengineering, Stanford University, Stanford, California, USA
| |
Collapse
|
8
|
Wang X, Albrecht JC, Lin JS, Barron AE. Monodisperse, "highly" positively charged protein polymer drag-tags generated in an intein-mediated purification system used in free-solution electrophoretic separations of DNA. Biomacromolecules 2011; 13:117-23. [PMID: 22168388 DOI: 10.1021/bm2013313] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Free-solution conjugate electrophoresis (FSCE) is a method of DNA sequencing that eliminates the need for viscous polymer solutions by tethering a carefully designed, mobility modifying "drag-tag" to each DNA molecule to achieve size-based separations of DNA. The most successful drag-tags to date are genetically engineered, highly repetitive polypeptides ("protein polymers") that are designed to be large, water-soluble, and completely monodisperse. Positively charged arginines were deliberately introduced at regular intervals into the amino acid sequence to increase the hydrodynamic drag without increasing drag-tag length. Additionally, a one-step purification method that combines affinity chromatography and on-column tag cleavage was devised to achieve the required drag-tag monodispersity. Sequencing with a read length of approximately 180 bases was successfully achieved with a known sequence in free-solution electrophoresis using one of these positively charged drag-tags. This preliminary result is expected to lead to further progress in FSCE sequencing with ~400 bases read length possible when more "highly" positively charged protein polymers of larger size are generated with the intein system.
Collapse
Affiliation(s)
- Xiaoxiao Wang
- Departments of Bioengineering, Stanford University, Stanford, California 94305, United States
| | | | | | | |
Collapse
|