1
|
Sharma K, Sharma M. Optical biosensors for environmental monitoring: Recent advances and future perspectives in bacterial detection. ENVIRONMENTAL RESEARCH 2023; 236:116826. [PMID: 37543133 DOI: 10.1016/j.envres.2023.116826] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 07/24/2023] [Accepted: 08/03/2023] [Indexed: 08/07/2023]
Abstract
The environmental contamination due to bacterial proliferation vs their identification is the major deciding factor in the spread of diseases leading to pandemics. The advent of drug-resistant pathogenic contaminants in our environment has further added to the load of complications associated with their diagnosis and treatment. Obstructing the spread of such infections, prioritizes the expansion of sensor-based diagnostics, effectuating, a sturdy detection of disease-causing microbes, contaminating our surroundings in shortest possible time, with minimal expenditure. Among many sensors known, optical biosensors promote the recognition of pathogens befouling the environment through a comparatively intuitive, brisk, portable, multitudinous, and thrifty approach. This article reviews the recent progresses in optical biosensor-based systems for effective environmental monitoring. The technical and methodological perspectives of fundamental optical-sensing platforms are reviewed, combined with the pros and cons of every procedure. Eventually, the obstacles lying in the path of development of an effective optical biosensor device for bio-monitoring and its future perspectives are highlighted in the present work.
Collapse
Affiliation(s)
- Kajal Sharma
- Molecular Genetics of Aging, Dr. B.R. Ambedkar Center for Biomedical Research (ACBR), University of Delhi (DU), India.
| | - Meenakshi Sharma
- Molecular Genetics of Aging, Dr. B.R. Ambedkar Center for Biomedical Research (ACBR), University of Delhi (DU), India.
| |
Collapse
|
2
|
Sabra DM, Krin A, Romeral AB, Frieß JL, Jeremias G. Anthrax revisited: how assessing the unpredictable can improve biosecurity. Front Bioeng Biotechnol 2023; 11:1215773. [PMID: 37795173 PMCID: PMC10546327 DOI: 10.3389/fbioe.2023.1215773] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 07/24/2023] [Indexed: 10/06/2023] Open
Abstract
B. anthracis is one of the most often weaponized pathogens. States had it in their bioweapons programs and criminals and terrorists have used or attempted to use it. This study is motivated by the narrative that emerging and developing technologies today contribute to the amplification of danger through greater easiness, accessibility and affordability of steps in the making of an anthrax weapon. As states would have way better preconditions if they would decide for an offensive bioweapons program, we focus on bioterrorism. This paper analyzes and assesses the possible bioterrorism threat arising from advances in synthetic biology, genome editing, information availability, and other emerging, and converging sciences and enabling technologies. Methodologically we apply foresight methods to encourage the analysis of contemporary technological advances. We have developed a conceptual six-step foresight science framework approach. It represents a synthesis of various foresight methodologies including literature review, elements of horizon scanning, trend impact analysis, red team exercise, and free flow open-ended discussions. Our results show a significant shift in the threat landscape. Increasing affordability, widespread distribution, efficiency, as well as ease of use of DNA synthesis, and rapid advances in genome-editing and synthetic genomic technologies lead to an ever-growing number and types of actors who could potentially weaponize B. anthracis. Understanding the current and future capabilities of these technologies and their potential for misuse critically shapes the current and future threat landscape and underlines the necessary adaptation of biosecurity measures in the spheres of multi-level political decision making and in the science community.
Collapse
Affiliation(s)
- Dunja Manal Sabra
- Carl Friedrich von Weizsäcker-Centre for Science and Peace Research (ZNF), University of Hamburg, Bogenallee, Hamburg, Germany
| | | | | | | | | |
Collapse
|
3
|
Wang Q, Dong J, Li Z, Wang X, He Y, Chen B, Zhao D. Dual-Emitting Mixed-Lanthanide Metal-Organic Framework for Ratiometric and Quantitative Visual Detection of 2,6-Pyridine Dicarboxylic Acid. Inorg Chem 2023; 62:14439-14447. [PMID: 37595269 DOI: 10.1021/acs.inorgchem.3c02374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/20/2023]
Abstract
The detection of the major biomarker of Bacillus anthracis, 2,6-dipicolinic acid (DPA), has attracted great interest in recent years. In this work, mixed-lanthanide metal-organic frameworks (M'LnMOFs), TbxEu1-x-cppa (cppa = 5-(5-carboxypyridin-3-yl)isophthalic acid), with different Tb/Eu ratios, were solvothermally synthesized. The results reveal that ratiometric fluorescent probe [Tb0.533Eu0.467-(Hcppa)1.5(H2O)(DMF)]·3H2O is water and acid-base stable and exhibits excellent sensitivity (LOD = 2.286 μM), high selectivity, and fast response (<2 min) for the detection of DPA. Due to the blocked energy transfer from Tb3+ to Eu3+ and the inner filter effect upon the addition of DPA, the fluorescent probe shows a distinct color change from orange-red to green. Furthermore, the visual detection of DPA was realized by identifying the RGB values of MOF-based agarose hydrogel films via a smartphone, highlighting the practical application of the fluorescent probe for DPA detection under aqueous solution conditions.
Collapse
Affiliation(s)
- Qin Wang
- Key Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Materials Science, Zhejiang Normal University, Jinhua 321004, Zhejiang, China
| | - Jiangnan Dong
- Key Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Materials Science, Zhejiang Normal University, Jinhua 321004, Zhejiang, China
| | - Zhangjian Li
- Key Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Materials Science, Zhejiang Normal University, Jinhua 321004, Zhejiang, China
| | - Xinyi Wang
- Key Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Materials Science, Zhejiang Normal University, Jinhua 321004, Zhejiang, China
| | - Yabing He
- Key Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Materials Science, Zhejiang Normal University, Jinhua 321004, Zhejiang, China
| | - Banglin Chen
- Key Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Materials Science, Zhejiang Normal University, Jinhua 321004, Zhejiang, China
- Fujian Provincial Key Laboratory of Polymer Materials, College of Chemistry and Materials Science, Fujian Normal University, Fuzhou 350007, China
| | - Dian Zhao
- Key Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Materials Science, Zhejiang Normal University, Jinhua 321004, Zhejiang, China
| |
Collapse
|
4
|
Nishanth MAD, Gourkhede D, Paidipally L, Borse R, Pollumahanti N, Nair A, Kiranmayee B, Malik SVS, Barbuddhe SB, Rawool DB. Comparative evaluation of in-house developed latex agglutination test (LAT) with World Organisation for Animal Health (WOAH) -recommended methods for the detection of Bacillus anthracis spores from the soil. J Microbiol Methods 2023; 211:106778. [PMID: 37394181 DOI: 10.1016/j.mimet.2023.106778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 06/26/2023] [Accepted: 06/29/2023] [Indexed: 07/04/2023]
Abstract
In-house developed Bacillus anthracis-specific synthetic peptide-based latex agglutination test (LAT) assay was comparatively evaluated with World Organisation for Animal Health (WOAH)-recommended polymerase chain reaction (PCR)/real-time PCR (qPCR) methods for the screening of B. anthracis spores from the soil to provide a simple, rapid, and economical immunodiagnostic test for field application.
Collapse
Affiliation(s)
- Maria Anto Dani Nishanth
- ICAR- National Meat Research Institute, Hyderabad 500 092, India; Division of Veterinary Public Health, ICAR-Indian Veterinary Research Institute, Izatnagar 243 122, India
| | - Diksha Gourkhede
- Division of Veterinary Public Health, ICAR-Indian Veterinary Research Institute, Izatnagar 243 122, India
| | | | - Rushikesh Borse
- Division of Veterinary Public Health, ICAR-Indian Veterinary Research Institute, Izatnagar 243 122, India
| | | | - Amruta Nair
- ICAR- National Meat Research Institute, Hyderabad 500 092, India
| | - Bhimavarapu Kiranmayee
- Division of Veterinary Public Health, ICAR-Indian Veterinary Research Institute, Izatnagar 243 122, India
| | - Satya Veer Singh Malik
- Division of Veterinary Public Health, ICAR-Indian Veterinary Research Institute, Izatnagar 243 122, India
| | | | | |
Collapse
|
5
|
Alp M, Pamuk Algi M, Algi F. Eu(III)-DO3A and BODIPY dyad as a chemosensor for anthrax biomarker. LUMINESCENCE 2021; 36:1953-1960. [PMID: 34337847 DOI: 10.1002/bio.4129] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 07/21/2021] [Accepted: 07/29/2021] [Indexed: 12/14/2022]
Abstract
The sensitive and selective determination of Bacillus anthracis spores before the infection is vital for human health and safety. Dipicolinic acid (DPA) is an excellent biomarker due to its presence in the nucleus of bacterial spores at high concentrations (up to 1 M, about 15% dry weight). In the present work, a new molecular chemosensor 1, based on europium(III)-DO3A and BODIPY dyad, is developed to detect DPA in phosphate-buffered saline (PBS) buffered solution and tap water samples. Also, 1 can be used as a ratiometric optical chemosensor to track DPA.
Collapse
Affiliation(s)
- Meltem Alp
- Department of Biotechnology & ASUBTAM Memduh Bilmez BioNanoTech Laboratory, Aksaray University, Aksaray, Turkey
| | - Melek Pamuk Algi
- Department of Chemistry & ASUBTAM Memduh Bilmez BioNanoTech Laboratory, Aksaray University, Aksaray, Turkey
| | - Fatih Algi
- Department of Biotechnology & ASUBTAM Memduh Bilmez BioNanoTech Laboratory, Aksaray University, Aksaray, Turkey
| |
Collapse
|
6
|
Gao N, Zhang Y, Huang P, Xiang Z, Wu FY, Mao L. Perturbing Tandem Energy Transfer in Luminescent Heterobinuclear Lanthanide Coordination Polymer Nanoparticles Enables Real-Time Monitoring of Release of the Anthrax Biomarker from Bacterial Spores. Anal Chem 2018; 90:7004-7011. [DOI: 10.1021/acs.analchem.8b01365] [Citation(s) in RCA: 83] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
- Nan Gao
- College of Chemistry, Nanchang University, Nanchang 330031, China
| | - Yunfang Zhang
- College of Chemistry, Nanchang University, Nanchang 330031, China
| | - Pengcheng Huang
- College of Chemistry, Nanchang University, Nanchang 330031, China
| | - Zhehao Xiang
- College of Chemistry, Nanchang University, Nanchang 330031, China
| | - Fang-Ying Wu
- College of Chemistry, Nanchang University, Nanchang 330031, China
| | - Lanqun Mao
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing 100190, China
| |
Collapse
|
7
|
Duracova M, Klimentova J, Fucikova A, Dresler J. Proteomic Methods of Detection and Quantification of Protein Toxins. Toxins (Basel) 2018; 10:toxins10030099. [PMID: 29495560 PMCID: PMC5869387 DOI: 10.3390/toxins10030099] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Revised: 02/21/2018] [Accepted: 02/23/2018] [Indexed: 12/11/2022] Open
Abstract
Biological toxins are a heterogeneous group of compounds that share commonalities with biological and chemical agents. Among them, protein toxins represent a considerable, diverse set. They cover a broad range of molecular weights from less than 1000 Da to more than 150 kDa. This review aims to compare conventional detection methods of protein toxins such as in vitro bioassays with proteomic methods, including immunoassays and mass spectrometry-based techniques and their combination. Special emphasis is given to toxins falling into a group of selected agents, according to the Centers for Disease Control and Prevention, such as Staphylococcal enterotoxins, Bacillus anthracis toxins, Clostridium botulinum toxins, Clostridium perfringens epsilon toxin, ricin from Ricinus communis, Abrin from Abrus precatorius or control of trade in dual-use items in the European Union, including lesser known protein toxins such as Viscumin from Viscum album. The analysis of protein toxins and monitoring for biological threats, i.e., the deliberate spread of infectious microorganisms or toxins through water, food, or the air, requires rapid and reliable methods for the early identification of these agents.
Collapse
Affiliation(s)
- Miloslava Duracova
- Faculty of Military Health Sciences, University of Defense in Brno, Třebešská 1575, CZ-500 01 Hradec Králové, Czech Republic.
| | - Jana Klimentova
- Faculty of Military Health Sciences, University of Defense in Brno, Třebešská 1575, CZ-500 01 Hradec Králové, Czech Republic.
| | - Alena Fucikova
- Faculty of Military Health Sciences, University of Defense in Brno, Třebešská 1575, CZ-500 01 Hradec Králové, Czech Republic.
| | - Jiri Dresler
- Military Health Institute, Military Medical Agency, Tychonova 1, CZ-160 00 Prague 6, Czech Republic.
| |
Collapse
|
8
|
Tan Y, Tian T, Liu W, Zhu Z, J Yang C. Advance in phage display technology for bioanalysis. Biotechnol J 2016; 11:732-45. [PMID: 27061133 DOI: 10.1002/biot.201500458] [Citation(s) in RCA: 53] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2015] [Revised: 01/30/2016] [Accepted: 03/15/2016] [Indexed: 11/06/2022]
Abstract
Phage display technology has emerged as a powerful tool for target gene expression and target-specific ligand selection. It is widely used to screen peptides, proteins and antibodies with the advantages of simplicity, high efficiency and low cost. A variety of targets, including ions, small molecules, inorganic materials, natural and biological polymers, nanostructures, cells, bacteria, and even tissues, have been demonstrated to generate specific binding ligands by phage display. Phages and target-specific ligands screened by phage display have been widely used as affinity reagents in therapeutics, diagnostics and biosensors. In this review, comparisons of different types of phage display systems are first presented. Particularly, microfluidic-based phage display, which enables screening with high throughput, high efficiency and integration, is highlighted. More importantly, we emphasize the advances in biosensors based on phages or phage-derived probes, including nonlytic phages, lytic phages, peptides or proteins screened by phage display, phage assemblies and phage-nanomaterial complexes. However, more efficient and higher throughput phage display methods are still needed to meet an explosion in demand for bioanalysis. Furthermore, screening of cyclic peptides and functional peptides will be the hotspot in bioanalysis.
Collapse
Affiliation(s)
- Yuyu Tan
- State Key Laboratory of Physical Chemistry of Solid Surfaces, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, China
| | - Tian Tian
- State Key Laboratory of Physical Chemistry of Solid Surfaces, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, China
| | - Wenli Liu
- State Key Laboratory of Physical Chemistry of Solid Surfaces, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, China
| | - Zhi Zhu
- State Key Laboratory of Physical Chemistry of Solid Surfaces, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, China.
| | - Chaoyong J Yang
- State Key Laboratory of Physical Chemistry of Solid Surfaces, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, China
| |
Collapse
|
9
|
Srinivasan B, Tung S. Development and Applications of Portable Biosensors. ACTA ACUST UNITED AC 2015; 20:365-89. [DOI: 10.1177/2211068215581349] [Citation(s) in RCA: 122] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2014] [Indexed: 02/01/2023]
|
10
|
Advances in Anthrax Detection: Overview of Bioprobes and Biosensors. Appl Biochem Biotechnol 2015; 176:957-77. [PMID: 25987133 DOI: 10.1007/s12010-015-1625-z] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2014] [Accepted: 04/08/2015] [Indexed: 12/22/2022]
Abstract
Anthrax is an infectious disease caused by Bacillus anthracis. Although anthrax commonly affects domestic and wild animals, it causes a rare but lethal infection in humans. A variety of techniques have been introduced and evaluated to detect anthrax using cultures, polymerase chain reaction, and immunoassays to address the potential threat of anthrax being used as a bioweapon. The high-potential harm of anthrax in bioterrorism requires sensitive and specific detection systems that are rapid, field-ready, and real-time monitoring. Here, we provide a systematic overview of anthrax detection probes with their potential applications in various ultra-sensitive diagnostic systems.
Collapse
|
11
|
Gupta R, Reifenberger RG, Kulkarni GU. Cellphone camera imaging of a periodically patterned chip as a potential method for point-of-care diagnostics. ACS APPLIED MATERIALS & INTERFACES 2014; 6:3923-3929. [PMID: 24564576 DOI: 10.1021/am4050426] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In this study, we demonstrate that a disposable chip periodically patterned with suitable ligands, an ordinary cellphone camera, and a simple pattern recognition software, can potentially be used for quantitative diagnostics. A key factor in this demonstration is the design of a calibration grid around the chip that, through a contrast transfer process, enables reliable analysis of the images collected under variable ambient lighting conditions. After exposure to a dispersion of amine terminated silica beads used as analyte mimicking pathogens, an epoxy-terminated glass substrate microcontact printed with octadecyltrichlorosilane (250 μm periodicity) developed a characteristic pattern of beads which could be easily imaged with a cellphone camera of 3.2 MP pixels. A simple pattern recognition algorithm using fast Fourier transform produced a quantitative estimate of the analyte concentration present in the test solution. In this method importantly, neither the chip fabrication process nor the fill-factor of the periodic pattern need be perfect to arrive at a conclusive diagnosis. The method suggests a viable platform that may potentially find use in fault-tolerant and robust point-of-care diagnostic applications.
Collapse
Affiliation(s)
- Ritu Gupta
- Chemistry and Physics of Materials Unit, DST Unit on Nanoscience, Jawaharlal Nehru Centre for Advanced Scientific Research , Jakkur P.O., Bangalore, Karnataka 560064, India
| | | | | |
Collapse
|
12
|
Freitas SC, Maia S, Figueiredo AC, Gomes P, Pereira PJ, Barbosa MA, Martins MCL. Selective albumin-binding surfaces modified with a thrombin-inhibiting peptide. Acta Biomater 2014; 10:1227-37. [PMID: 24316365 DOI: 10.1016/j.actbio.2013.11.023] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2013] [Revised: 11/13/2013] [Accepted: 11/25/2013] [Indexed: 10/25/2022]
Abstract
Blood-contacting medical devices have been associated with severe clinical complications, such as thrombus formation, triggered by the activation of the coagulation cascade due to the adsorption of certain plasma proteins on the surface of biomaterials. Hence, the coating of such surfaces with antithrombotic agents has been used to increase biomaterial haemocompatibility. Biomaterial-induced clotting may also be decreased by albumin adsorption from blood plasma in a selective and reversible way, since this protein is not involved in the coagulation cascade. In this context, this paper reports that the immobilization of the thrombin inhibitor D-Phe-Pro-D-Arg-D-Thr-CONH2 (fPrt) onto nanostructured surfaces induces selective and reversible adsorption of albumin, delaying the clotting time when compared to peptide-free surfaces. fPrt, synthesized with two glycine residues attached to the N-terminus (GGfPrt), was covalently immobilized onto self-assembled monolayers (SAMs) having different ratios of carboxylate-hexa(ethylene glycol)- and tri(ethylene glycol)-terminated thiols (EG6-COOH/EG3) that were specifically designed to control GGfPrt orientation, exposure and density at the molecular level. In solution, GGfPrt was able to inactivate the enzymatic activity of thrombin and to delay plasma clotting time in a concentration-dependent way. After surface immobilization, and independently of its concentration, GGfPrt lost its selectivity to thrombin and its capacity to inhibit thrombin enzymatic activity against the chromogenic substrate n-p-tosyl-Gly-Pro-Arg-p-nitroanilide. Nevertheless, surfaces with low concentrations of GGfPrt could delay the capacity of adsorbed thrombin to cleave fibrinogen. In contrast, GGfPrt immobilized in high concentrations was found to induce the procoagulant activity of the adsorbed thrombin. However, all surfaces containing GGfPrt have a plasma clotting time similar to the negative control (empty polystyrene wells), showing resistance to coagulation, which is explained by its capacity to adsorb albumin in a selective and reversible way. This work opens new perspectives to the improvement of the haemocompatibility of blood-contacting medical devices.
Collapse
|
13
|
Existence of separate domains in lysin PlyG for recognizing Bacillus anthracis spores and vegetative cells. Antimicrob Agents Chemother 2012; 56:5031-9. [PMID: 22802245 DOI: 10.1128/aac.00891-12] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
As a potential antimicrobial, the bacteriophage lysin PlyG has been reported to specifically recognize Bacillus anthracis vegetative cells only and to kill B. anthracis vegetative cells and its germinating spores. However, how PlyG interacts with B. anthracis spores remains unclear. Herein, a 60-amino-acid domain in PlyG (residues 106 to 165), located mainly in the previously identified catalytic domain, was found able to specifically recognize B. anthracis spores but not vegetative cells. The exosporium of the spores was found to be the most probable binding target of this domain. This is the first time that a lysin for spore-forming bacteria has been found to have separate domains to recognize spores and vegetative cells, which might help in understanding the coevolution of phages with spore-forming bacteria. Besides providing new biomarkers for developing better assays for identifying B. anthracis spores, the newly found domain may be helpful in developing PlyG as a preventive antibiotic to reduce the threat of anthrax in suspected exposures to B. anthracis spores.
Collapse
|
14
|
Examination of Bacillus anthracis spores by multiparameter flow cytometry. Methods Mol Biol 2011. [PMID: 21567316 DOI: 10.1007/978-1-61779-102-4_4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
The ability to rapidly differentiate Bacillus anthracis spores from spores belonging to other Bacillus spp. is potentially useful for combating the intentional release of this biothreat agent. Furthermore, not all B. anthracis strains are fully virulent and the ability to determine the potential virulence of the endospore is also important. In this chapter, we describe a two-color flow cytometric assay capable of simultaneously identifying B. anthracis spores and the presence of spore-associated protective antigen, a virulence marker for strains harboring the pXO1 plasmid.
Collapse
|
15
|
Bharadwaj R, Sai V, Thakare K, Dhawangale A, Kundu T, Titus S, Verma PK, Mukherji S. Evanescent wave absorbance based fiber optic biosensor for label-free detection of E. coli at 280nm wavelength. Biosens Bioelectron 2011; 26:3367-70. [DOI: 10.1016/j.bios.2010.12.014] [Citation(s) in RCA: 84] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2010] [Revised: 11/16/2010] [Accepted: 12/08/2010] [Indexed: 11/26/2022]
|
16
|
Torrisi V, Amato ME, Ballistreri FP, Tomaselli G, Toscano RM, Licciardello A. Surface anchoring of a chiral salen macrocycle on a carboxy-functionalized platform via a multiple site esterification. SURF INTERFACE ANAL 2010. [DOI: 10.1002/sia.3690] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
17
|
Detection technologies for Bacillus anthracis: Prospects and challenges. J Microbiol Methods 2010; 82:1-10. [DOI: 10.1016/j.mimet.2010.04.005] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2010] [Revised: 04/09/2010] [Accepted: 04/12/2010] [Indexed: 01/20/2023]
|
18
|
Kim J, Yoon MY. Recent advances in rapid and ultrasensitive biosensors for infectious agents: lesson from Bacillus anthracis diagnostic sensors. Analyst 2010; 135:1182-90. [PMID: 20498871 DOI: 10.1039/c0an00030b] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Here, we review the cumulative efforts to develop rapid and ultrasensitive diagnostic systems, especially for the infectious agent, Bacillus anthracis, as a model system. This Minireview focuses on demonstrating the features of various probes for target molecule detection and recent methods of signal generation within the biosensors. Also, we discuss the possibility of using peptides as next-generation probe molecules.
Collapse
Affiliation(s)
- Joungmok Kim
- Department of Chemistry, Research Institute for Natural Sciences, Hanyang University, Seoul 133-791, Korea
| | | |
Collapse
|
19
|
Sainath Rao S, Mohan KVK, Nguyen N, Abraham B, Abdouleva G, Zhang P, Atreya CD. Peptides panned from a phage-displayed random peptide library are useful for the detection of Bacillus anthracis surrogates B. cereus 4342 and B. anthracis Sterne. Biochem Biophys Res Commun 2010; 395:93-8. [PMID: 20350526 DOI: 10.1016/j.bbrc.2010.03.145] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2010] [Accepted: 03/24/2010] [Indexed: 11/18/2022]
Abstract
Recent use of Bacillus anthracis as a bioweapon has highlighted the need for a sensitive monitoring system. Current bacterial detection tests use antibodies as bio-molecular recognition elements which have limitations with regard to time, specificity and sensitivity, creating the need for new and improved cost-effective high-affinity detection probes. In this study, we screened a commercially available bacteriophage-displayed random peptide library using Bacillus cereus 4342 cells as bait to identify peptides that could be used for detection of Bacillus. The method enabled us to identify two 12-amino acid consensus peptide sequences that specifically bind to B. cereus 4342 and B. anthracis Sterne, the nonpathogenic surrogates of B. anthracis strain. The two Bacillus-binding peptides (named BBP-1 and BBP-2) were synthesized with biotin tag to confirm their binding by four independent detection assays. Dot-blot analysis revealed that the peptides bind specifically to B. cereus 4342 and B. anthracis Sterne. Quantitative analysis of this interaction by ELISA and fluorometry demonstrated a detection sensitivity of 10(2) colony forming U/ml (CFU/ml) by both assays. When the peptides were used in combination with Qdots, the sensitivity was enhanced further by enabling detection of even a single bacterium by fluorescence microscopy. Immunoblot analysis and protein sequencing showed that BBP-1 and BBP-2 bound to the S-layer protein of B. anthracis Sterne. Overall, our findings validate the usefulness of synthetic versions of phage-derived peptides in combination with Qdot-liquid nanocrystals as high sensitivity bioprobes for various microbial detection platforms.
Collapse
Affiliation(s)
- Shilpakala Sainath Rao
- Section of Cell Biology, Laboratory of Cellular Hematology, Center for Biologics Evaluation and Research, FDA, Bethesda, MD 20892, USA
| | | | | | | | | | | | | |
Collapse
|
20
|
Lisowski CE, Hutchison JE. Malonamide-Functionalized Gold Nanoparticles for Selective, Colorimetric Sensing of Trivalent Lanthanide Ions. Anal Chem 2009; 81:10246-53. [DOI: 10.1021/ac902271t] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Carmen E. Lisowski
- Department of Chemistry and Materials Science Institute, University of Oregon, Eugene, Oregon 97403-1253
| | - James E. Hutchison
- Department of Chemistry and Materials Science Institute, University of Oregon, Eugene, Oregon 97403-1253
| |
Collapse
|
21
|
Square wave voltammetric detection of Anthrax utilizing a peptide for selective recognition of a protein biomarker. Biosens Bioelectron 2009; 25:469-74. [DOI: 10.1016/j.bios.2009.08.002] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2009] [Revised: 07/17/2009] [Accepted: 08/03/2009] [Indexed: 11/19/2022]
|
22
|
Implications of limits of detection of various methods for Bacillus anthracis in computing risks to human health. Appl Environ Microbiol 2009; 75:6331-9. [PMID: 19648357 DOI: 10.1128/aem.00288-09] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
Used for decades for biological warfare, Bacillus anthracis (category A agent) has proven to be highly stable and lethal. Quantitative risk assessment modeling requires descriptive statistics of the limit of detection to assist in defining the exposure. Furthermore, the sensitivities of various detection methods in environmental matrices are vital information for first responders. A literature review of peer-reviewed journal articles related to methods for detection of B. anthracis was undertaken. Articles focused on the development or evaluation of various detection approaches, such as PCR, real-time PCR, immunoassay, etc. Real-time PCR and PCR were the most sensitive methods for the detection of B. anthracis, with median instrument limits of detection of 430 and 440 cells/ml, respectively. There were very few peer-reviewed articles on the detection methods for B. anthracis in the environment. The most sensitive limits of detection for the environmental samples were 0.1 CFU/g for soil using PCR-enzyme-linked immunosorbent assay (ELISA), 17 CFU/liter for air using an ELISA-biochip system, 1 CFU/liter for water using cultivation, and 1 CFU/cm(2) for stainless steel fomites using cultivation. An exponential dose-response model for the inhalation of B. anthracis estimates of risk at concentrations equal to the environmental limit of detection determined the probability of death if untreated to be as high as 0.520. Though more data on the environmental limit of detection would improve the assumptions made for the risk assessment, this study's quantification of the risk posed by current limitations in the knowledge of detection methods should be considered when employing those methods in environmental monitoring and cleanup strategies.
Collapse
|
23
|
Identification and characterization of Bacillus anthracis spores by multiparameter flow cytometry. Appl Environ Microbiol 2008; 74:5220-3. [PMID: 18586967 DOI: 10.1128/aem.00369-08] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
In response to the need for methods that can rapidly detect potentially virulent Bacillus anthracis spores, we developed a two-color flow cytometric assay capable of simultaneously identifying B. anthracis spores and the presence of spore-associated protective antigen, a virulence marker for strains harboring the pXO1 plasmid.
Collapse
|
24
|
Simpson-Stroot JM, Kearns EA, Stroot PG, Magaña S, Lim DV. Monitoring biosensor capture efficiencies: development of a model using GFP-expressing Escherichia coli O157:H7. J Microbiol Methods 2007; 72:29-37. [PMID: 18096260 DOI: 10.1016/j.mimet.2007.11.004] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2007] [Revised: 11/09/2007] [Accepted: 11/09/2007] [Indexed: 11/15/2022]
Abstract
One of the known limitations for biosensor assays is the high limit of detection for target cells within complex samples (e.g., Escherichia coli at 10(4) to 10(5) CFU/mL) due to poor capture efficiencies. Currently, researchers can only estimate the cell capture efficiency necessary to produce a positive signal for any type of biosensor using either cumbersome techniques or regression modeling. To solve this problem, green fluorescent protein (GFP) transformed E. coli O157:H7 was used to develop a novel method for directly and easily measuring the cell capture efficiency of any given biosensor platform. For demonstration purposes, E. coli-GFP was assayed on both fiber optic and planar waveguide biosensor platforms. Cells were enumerated using an epifluorescent microscope and digital camera to determine the number of cells captured on the surfaces. Conversion algorithms were used with these digital images to determine the cell density of entire waveguide surface areas. For E. coli-GFP, the range of cell capture efficiency was between 0.4 and 1.2%. This indicates that although the developed model works for calculating cell capture, there is still need for significant improvements in capture methods themselves, to increase the capture efficiency and thereby lower detection limits. The use of GFP-transformed target cells and cell capture efficiency calculations can facilitate the development and optimization processes by allowing direct enumeration of new biosensor design configurations and sample processing strategies.
Collapse
Affiliation(s)
- Joyce M Simpson-Stroot
- Division of Cell Biology, Microbiology, and Molecular Biology, Department of Biology, University of South Florida, Tampa, FL 33620-5200, USA.
| | | | | | | | | |
Collapse
|