Schaefer C, Lippmann M, Schindler C, Beukers M, Beijer N, Hitzemann M, van de Kamp B, Peters R, Knotter J, Zimmermann S. Pursuing drug laboratories: Analysis of drug precursors with High Kinetic Energy Ion Mobility Spectrometry. Forensic Sci Int 2024; 363:112196. [PMID: 39151243 DOI: 10.1016/j.forsciint.2024.112196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2024] [Revised: 08/06/2024] [Accepted: 08/13/2024] [Indexed: 08/19/2024]
Abstract
High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS) is a technique for rapid and reliable detection of trace compounds down to ppbV-levels within one second. Compared to classical IMS operating at ambient pressure and providing the ion mobility at low electric fields, HiKE-IMS can also provide the analyte-specific field dependence of the ion mobility and a fragmentation pattern at high reduced electric field strengths. The additional information about the analyte obtained by varying the reduced electric field strength can contribute to reliable detection. Furthermore, the reduced number of ion-molecule reactions at the low operating pressure of 10 - 40 mbar and the shorter reaction times reduce the impact of competing ion-molecule reactions that can cause false negatives. In this work, we employ HiKE-IMS for the analysis of phenyl-2-propanone (P2P) and other precursor chemicals used for synthesis of methamphetamine and amphetamine. The results show that the precursor chemicals exhibit different behavior in HiKE-IMS. Some precursors form a single significant ion species, while others readily form a fragmentation pattern. Nevertheless, all drug precursors can be distinguished from each other, from the reactant ions and from interfering compounds. In particular, the field-dependent ion mobility as an additional separation dimension aids identification, potentially reducing the number of false positive alarms in field applications. Furthermore, the analysis of a seized illicit P2P sample shows that even low levels of P2P can be detected despite the complex background present in the headspace of real samples.
Collapse
Affiliation(s)
- Christoph Schaefer
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, Hannover 30167, Germany.
| | - Martin Lippmann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, Hannover 30167, Germany
| | - Clara Schindler
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, Hannover 30167, Germany
| | - Michiel Beukers
- Research Group Technologies for Criminal Investigations, Saxion University of Applied Sciences, M.H Tromplaan 28, Enschede 7513AB, the Netherlands; Knowledge Centre of Digitalization, Intelligence and Technology, Police Academy of the Netherlands, Arnhemseweg 348, Apeldoorn 7334AC, the Netherlands
| | - Niels Beijer
- Research Group Technologies for Criminal Investigations, Saxion University of Applied Sciences, M.H Tromplaan 28, Enschede 7513AB, the Netherlands; Knowledge Centre of Digitalization, Intelligence and Technology, Police Academy of the Netherlands, Arnhemseweg 348, Apeldoorn 7334AC, the Netherlands
| | - Moritz Hitzemann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, Hannover 30167, Germany
| | - Ben van de Kamp
- Research Group Technologies for Criminal Investigations, Saxion University of Applied Sciences, M.H Tromplaan 28, Enschede 7513AB, the Netherlands; Knowledge Centre of Digitalization, Intelligence and Technology, Police Academy of the Netherlands, Arnhemseweg 348, Apeldoorn 7334AC, the Netherlands
| | - Ruud Peters
- Research Group Technologies for Criminal Investigations, Saxion University of Applied Sciences, M.H Tromplaan 28, Enschede 7513AB, the Netherlands; Knowledge Centre of Digitalization, Intelligence and Technology, Police Academy of the Netherlands, Arnhemseweg 348, Apeldoorn 7334AC, the Netherlands
| | - Jaap Knotter
- Research Group Technologies for Criminal Investigations, Saxion University of Applied Sciences, M.H Tromplaan 28, Enschede 7513AB, the Netherlands; Knowledge Centre of Digitalization, Intelligence and Technology, Police Academy of the Netherlands, Arnhemseweg 348, Apeldoorn 7334AC, the Netherlands
| | - Stefan Zimmermann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, Hannover 30167, Germany
| |
Collapse
|
2
|
Schaefer C, Allers M, Hitzemann M, Nitschke A, Kobelt T, Mörtel M, Schröder S, Ficks A, Zimmermann S. Reliable Detection of Chemical Warfare Agents Using High Kinetic Energy Ion Mobility Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:2008-2019. [PMID: 39013159 PMCID: PMC11311216 DOI: 10.1021/jasms.4c00240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Revised: 07/01/2024] [Accepted: 07/05/2024] [Indexed: 07/18/2024]
Abstract
High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) ionize and separate ions at reduced pressures of 10-40 mbar and over a wide range of reduced electric field strengths E/N of up to 120 Td. Their reduced operating pressure is distinct from that of conventional drift tube ion mobility spectrometers that operate at ambient pressure for trace compound detection. High E/N can lead to a field-induced fragmentation pattern that provides more specific structural information about the analytes. In addition, operation at high E/N values adds the field dependence of ion mobility as an additional separation dimension to low-field ion mobility, making interfering compounds less likely to cause a false positive alarm. In this work, we study the chemical warfare agents tabun (GA), sarin (GB), soman (GD), cyclosarin (GF) and sulfur mustard (HD) in a HiKE-IMS at variable E/N in both the reaction and the drift region. The results show that varying E/N can lead to specific fragmentation patterns at high E/N values combined with molecular signals at low E/N. Compared to the operation at a single E/N value in the drift region, the variation of E/N in the drift region also provides the analyte-specific field dependence of ion mobility as additional information. The accumulated data establish a unique fingerprint for each analyte that allows for reliable detection of chemical warfare agents even in the presence of interfering compounds with similar low-field ion mobilities, thus reducing false positives.
Collapse
Affiliation(s)
- Christoph Schaefer
- Institute
of Electrical Engineering and Measurement Technology, Department of
Sensors and Measurement Technology, Leibniz
University Hannover, Appelstr. 9A, 30167 Hannover, Germany
| | - Maria Allers
- Bundeswehr
Research Institute for Protective Technologies and CBRN Protection, Humboldtstrasse 100, 29633 Munster, Germany
| | - Moritz Hitzemann
- Institute
of Electrical Engineering and Measurement Technology, Department of
Sensors and Measurement Technology, Leibniz
University Hannover, Appelstr. 9A, 30167 Hannover, Germany
| | - Alexander Nitschke
- Institute
of Electrical Engineering and Measurement Technology, Department of
Sensors and Measurement Technology, Leibniz
University Hannover, Appelstr. 9A, 30167 Hannover, Germany
| | - Tim Kobelt
- Institute
of Electrical Engineering and Measurement Technology, Department of
Sensors and Measurement Technology, Leibniz
University Hannover, Appelstr. 9A, 30167 Hannover, Germany
| | - Max Mörtel
- Bundeswehr
Research Institute for Protective Technologies and CBRN Protection, Humboldtstrasse 100, 29633 Munster, Germany
| | - Stefanie Schröder
- Bundeswehr
Research Institute for Protective Technologies and CBRN Protection, Humboldtstrasse 100, 29633 Munster, Germany
| | - Arne Ficks
- Bundeswehr
Research Institute for Protective Technologies and CBRN Protection, Humboldtstrasse 100, 29633 Munster, Germany
| | - Stefan Zimmermann
- Institute
of Electrical Engineering and Measurement Technology, Department of
Sensors and Measurement Technology, Leibniz
University Hannover, Appelstr. 9A, 30167 Hannover, Germany
| |
Collapse
|
3
|
Haack A, Schaefer C, Zimmermann S. On the Arrival Time Distribution of Reacting Systems in Ion Mobility Spectrometry. Anal Chem 2024; 96. [PMID: 39009503 PMCID: PMC11295131 DOI: 10.1021/acs.analchem.4c02010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 06/13/2024] [Accepted: 07/09/2024] [Indexed: 07/17/2024]
Abstract
Ion mobility spectrometry (IMS) is a widely used gas-phase separation technique, particularly when coupled with mass spectrometry (MS). Modern IMS instruments often apply elevated reduced field strengths for improved ion separation and ion focusing. These alter the collision dynamics and further drive ion reaction processes that can change the analyte's structure. As a result, the measured arrival time distribution (ATD) can change with the applied reduced field strengths. In this work, we systematically study how the ion collision dynamics and the ion reaction dynamics, as a function of the reduced field strength, can alter the ATD. To this end, we investigate 2,6-di-tert-butylpyridine, methanol, and ethyl acetate using a home-built drift tube IMS coupled to a home-built MS and extensive first-principles Monte Carlo modeling. We show how elevated reduced field strengths can actually lower resolving power through increased ion diffusion and how the field dependency of the ion mobility can introduce uncertainties to collision cross sections (CCS) calculated from the measured mobilities. On top of the collision dynamics, we show how chemical transformation processes that alter the analyte's CCS, e.g., dynamic clustering or fragmentation, can lead to broadened, shifted, or non-Gaussian ATDs and how sensitive these processes are to the applied field strengths. We highlight how first-principles ion dynamics simulations can help to understand and even harness the mentioned effects.
Collapse
Affiliation(s)
- Alexander Haack
- Department of Sensors and
Measurement Technology, Institute of Electrical Engineering and Measurement
Technology, Leibniz University Hannover, 30167 Hannover, Germany
| | - Christoph Schaefer
- Department of Sensors and
Measurement Technology, Institute of Electrical Engineering and Measurement
Technology, Leibniz University Hannover, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Department of Sensors and
Measurement Technology, Institute of Electrical Engineering and Measurement
Technology, Leibniz University Hannover, 30167 Hannover, Germany
| |
Collapse
|
4
|
Haack A, Schaefer C, Zimmermann S, Hopkins WS. Validation of Field-Dependent Ion-Solvent Cluster Modeling via Direct Measurement of Cluster Size Distributions. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:1035-1046. [PMID: 37116175 DOI: 10.1021/jasms.3c00012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Ion mobility spectrometry is widely used in analytical chemistry, either as a stand-alone technique or coupled to mass spectrometry. Ions in the gas phase tend to form loosely bound clusters with surrounding solvent vapors, artificially increasing the collisional cross section and the mass of the ion. This, in turn, affects ion mobility and influences separation. Further, ion-solvent clusters play an important role in most ionization mechanisms occurring in the gas phase. Consequently, a deeper understanding of ion-solvent cluster association and dissociation processes is desirable to guide experimental design and interpretation. A few computational models exist, which aim to describe the amount of clustering as a function of the reduced electric field strength, bath gas pressure and temperature, and the chemical species probed. It is especially challenging to model ion mobility under high reduced electrical field strengths due to the nonthermal conditions created by the field. In this work, we aim to validate a recently proposed first-principles model by comparing its predictions with direct measurements of cluster size distributions over a range of 20-120 Td as observed using a High Kinetic Energy Ion Mobility Spectrometer coupled to a mass spectrometer (HiKE-IMS-MS). By studying H+(H2O)n, [MeOH + H + n(H2O)]+, [ACE + H + n(H2O)]+, and [PhNH2 + H + n(H2O)]+ as test systems, we find very good agreement between model and experiment, supporting the validity of the computational workflow. Further, the detailed information gained from the modeling yields important insights into the cluster dynamics within the HiKE-IMS, allowing for better interpretation of the measured ion mobility spectra.
Collapse
Affiliation(s)
- Alexander Haack
- Department of Chemistry, University of Waterloo, 200 University Avenue W, Waterloo, Ontario N2L 3G1, Canada
| | - Christoph Schaefer
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, 30167 Hannover, Germany
| | - W Scott Hopkins
- Department of Chemistry, University of Waterloo, 200 University Avenue W, Waterloo, Ontario N2L 3G1, Canada
- Watermine Innovation, Waterloo, Ontario N0B 2T0, Canada
- Centre for Eye and Vision Research, Hong Kong Science Park, New Territories, 999077, Hong Kong
| |
Collapse
|
5
|
Naylor CN, Clowers BH, Schlottmann F, Solle N, Zimmermann S. Implementation of an Open-Source Multiplexing Ion Gate Control for High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023. [PMID: 37276587 DOI: 10.1021/jasms.3c00013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
With ion mobility spectrometry increasingly used in mass spectrometry to enhance separation by increasing orthogonality, low ion throughput is a challenge for the drift-tube ion mobility experiment. The High Kinetic Energy Ion Mobility Spectrometer (HiKE-IMS) is no exception and routinely uses duty cycles of less than 0.1%. Multiplexing techniques such as Fourier transform and Hadamard transform represent two of the most common approaches used in the literature to improve ion throughput for the IMS experiment; these techniques promise increased duty cycles of up to 50% and an increased signal-to-noise ratio (SNR). With no instrument modifications required, we present the implementation of Hadamard Transform on the HiKE-IMS using a low cost, high-speed (600 MHz), open source microcontroller, a Teensy 4.1. Compared to signal average mode, 7- to 10-bit pseudorandom binary sequences resulted in increased analyte signal by over a factor of 3. However, the maximum SNR gain of 10 did not approach the theoretical 2n-1 gain largely due to capacitive coupling of the ion gate modulation with the Faraday plate used as a detector. Even when utilizing an inverse Hadamard technique, capacitive coupling was not completely eliminated. Regardless, the benefits of multiplexing IMS coupled to mass spectrometers are well documented throughout literature, and this first effort serves as a proof of concept for multiplexing HiKE-IMS. Finally, the highly flexible Teensy used in this effort can be used to multiplex other devices or can be used for Fourier transform instead of Hadamard transform.
Collapse
Affiliation(s)
- Cameron N Naylor
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, 30167 Hannover Germany
| | - Brian H Clowers
- Department of Chemistry, Washington State University, Pullman, Washington 99164, United States
| | - Florian Schlottmann
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, 30167 Hannover Germany
| | - Nic Solle
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, 30167 Hannover Germany
| | - Stefan Zimmermann
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, 30167 Hannover Germany
| |
Collapse
|
6
|
Schlottmann F, Schaefer C, Kirk AT, Bohnhorst A, Zimmermann S. A High Kinetic Energy Ion Mobility Spectrometer for Operation at Higher Pressures of up to 60 mbar. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:893-904. [PMID: 36999893 PMCID: PMC10161227 DOI: 10.1021/jasms.2c00365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) are usually operated at absolute pressures around 20 mbar in order to reach high reduced electric field strengths of up to 120 Td for influencing reaction kinetics in the reaction region. Such operating points significantly increase the linear range and limit chemical cross sensitivities. Furthermore, HiKE-IMS enables ionization of compounds normally not detectable in ambient pressure IMS, such as benzene, due to additional reaction pathways and fewer clustering reactions. However, operation at higher pressures promises increased sensitivity and smaller instrument size. In this work, we therefore study the theoretical requirements to prevent dielectric breakdown while maintaining high reduced electric field strengths at higher pressures. Furthermore, we experimentally investigate influences of the pressure, discharge currents and applied voltages on the corona ionization source. Based on these results, we present a HiKE-IMS that operates at a pressure of 60 mbar and reduced electric field strengths of up to 105 Td. The corona experiments show shark fin shaped curves for the total charge at the detector with a distinct optimum operating point in the glow discharge region at a corona discharge current of 5 μA. Here, the available charge is maximized while the generation of less-reactive ion species like NOx+ is minimized. With these settings, the reactant ion population, H3O+ and O2+, for ionizing and detecting nonpolar substances like n-hexane is still available even at 60 mbar, achieving a limit of detection of just 5 ppbV for n-hexane.
Collapse
Affiliation(s)
- Florian Schlottmann
- Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstr. 9a, 30167 Hannover, Germany
| | - Christoph Schaefer
- Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstr. 9a, 30167 Hannover, Germany
| | - Ansgar T Kirk
- Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstr. 9a, 30167 Hannover, Germany
| | - Alexander Bohnhorst
- Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstr. 9a, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstr. 9a, 30167 Hannover, Germany
| |
Collapse
|
7
|
Hitzemann M, Schaefer C, Kirk AT, Nitschke A, Lippmann M, Zimmermann S. Easy to assemble dielectric barrier discharge plasma ionization source based on printed circuit boards. Anal Chim Acta 2023; 1239:340649. [PMID: 36628746 DOI: 10.1016/j.aca.2022.340649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Revised: 11/14/2022] [Accepted: 11/20/2022] [Indexed: 11/29/2022]
Abstract
Here, we present a new and an easy to assemble dielectric barrier discharge plasma ionization source based on printed circuit boards with two parallel isolated electrodes for generating a plasma inside an inert fused silica capillary. For demonstration, this plasma source is coupled to an ion mobility spectrometer. With two different sample gas feeds the analytes can either pass through the plasma or bypass the plasma before entering the reaction region of the ion mobility spectrometer, allowing for different ionization pathways, e.g. electron impact ionization, ionization by excited species, e.g. helium metastables, or chemical ionization via reactant ions generated inside or downstream of the plasma. The plasma source, in particular, the electrode geometry and the capillary diameter were designed with the help of electric field simulations. A rectangular electrode with a height of at least twice the outer diameter of the capillary turned out to be ideal, in both the simulation and the experiment. Furthermore, a simple control electronics has been developed, which can be easily applied to other plasma sources. With the plasma source presented here, detection limits in the mid pptv range have been reached.
Collapse
Affiliation(s)
- Moritz Hitzemann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany.
| | - Christoph Schaefer
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany
| | - Ansgar T Kirk
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany
| | - Alexander Nitschke
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany
| | - Martin Lippmann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany
| | - Stefan Zimmermann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167, Hannover, Germany
| |
Collapse
|
8
|
Naylor CN, Schaefer C, Kirk AT, Zimmermann S. The origin of isomerization of aniline revealed by high kinetic energy ion mobility spectrometry (HiKE-IMS). Phys Chem Chem Phys 2023; 25:1139-1152. [PMID: 36515135 DOI: 10.1039/d2cp01994a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Although aniline is a relatively simple small molecule, the origin of its two peaks observed in ion mobility spectrometry (IMS) has remained under debate for at least 30 years. First hypothesized as a difference in protonation site (amine vs. benzene ring), each ion mobility peak differs by one Dalton when coupled with mass spectrometry where the faster mobility peak is the molecular ion peak, and the slower mobility peak is protonated. To complicate the deconvolution of structures, some previous literature shows the peaks as unresolved and thus proposes these species exist in equilibrium. In this work, we show that when measured with high kinetic energy ion mobility spectrometry (HiKE-IMS), the two peaks observed in spectra of both aniline and all n-fluoroanilines are fully separated (chromatographic resolution from 2-7, Rp > 110) and therefore not in equilibrium. The HiKE-IMS is capable of changing ionization conditions independently of drift region conditions, and our results agree with previous literature showing that ionization source settings (including possible fragmentation at this stage) are the only influence determining the speciation of the two aniline peaks. Finally, when the drift and reactant gas are changed to nitrogen, a third peak appears at high E/N for 2-fluoroaniline and 4-fluoroaniline for the first time in reported literature. As observed by HiKE-IMS-MS, the new third peak is also protonated showing that the para-protonated aniline and resulting fragment ion, molecular ion aniline, can be fully separated in the mobility domain for the first time. The appearance of the third peak is only possible due to the increased separation of the other two peaks within the HiKE-IMS.
Collapse
Affiliation(s)
- Cameron N Naylor
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, 30167 Hannover, Germany.
| | - Christoph Schaefer
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, 30167 Hannover, Germany.
| | - Ansgar T Kirk
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, 30167 Hannover, Germany.
| | - Stefan Zimmermann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, 30167 Hannover, Germany.
| |
Collapse
|
9
|
Haack A, Hopkins WS. Kinetics in DMS: Modeling Clustering and Declustering Reactions. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:2250-2262. [PMID: 36331115 DOI: 10.1021/jasms.2c00224] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Differential mobility spectrometry (DMS) uses high-frequency oscillating electrical fields to harness the differential mobility of ions for separating complex sample mixtures prior to detection. To increase the resolving power, a dynamic microsolvation environment is often created by introducing solvent vapors. Here, relatively large clusters are formed at low-field conditions which then evaporate to form smaller clusters at high-field conditions. The kinetics of these processes as the electrical field strength oscillates are not well studied. Here, we develop a computational framework to investigate how the different reactions (cluster association, cluster dissociation, and fast conformational changes) behave at different field strengths. We aim to better understand these processes, their effect on experimental outcomes, and whether DMS model accuracy is improved via incorporating their description. We find that cluster association and dissociation reactions for typical ion-solvent pairs are fast compared to the time scale of the varying separation fields usually used. However, low solvent concentration, small dipole moments, and strong ion-solvent binding can result in reaction rates small enough that a lag is observed in the ion's DMS response. This can yield differences of several volts in the compensation voltages required to correct ion trajectories for optimal transmission. We also find that the proposed kinetic approach yields generally better agreement with experiment than using a modified Boltzmann weighting scheme. Thus, this work provides insights into the chemical dynamics occurring within the DMS cell while also increasing the accuracy of dispersion plot predictions.
Collapse
Affiliation(s)
- Alexander Haack
- Department of Chemistry, University of Waterloo, 200 University Ave W, Waterloo, ONN2L 3G1, Canada
| | - W Scott Hopkins
- Department of Chemistry, University of Waterloo, 200 University Ave W, Waterloo, ONN2L 3G1, Canada
- Watermine Innovation, Waterloo, OntarioN0B 2T0, Canada
- Centre for Eye and Vision Research, Hong Kong Science Park, New Territories999077, Hong Kong
| |
Collapse
|
10
|
Schaefer C, Schlottmann F, Kirk AT, Zimmermann S. Influence of Sample Gas Humidity on Product Ion Formation in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:1048-1060. [PMID: 35594571 DOI: 10.1021/jasms.2c00099] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) chemically ionize gaseous samples via reactant ions and separate the generated ions by their motion in a neutral gas under the influence of an electric field. Operation at reduced pressures of 10-40 mbar allows for reaching high reduced electric field strengths (E/N) of up to 120 Td. At these high E/N, the generated ions gain the namesake high kinetic energies, leading to a decrease in cluster size of the reactant ions by increasing the reaction rate of collision-induced cluster dissociation of hydrates. In positive ion polarity and in purified air, H3O+(H2O)n, NO+(H2O)n, and O2+•(H2O)p are the most abundant reactant ions. In this work, we investigate the effect of varying sample gas humidity on product ion formation for several model substances. Results show that increasing the sample gas humidity at high E/N of 120 Td shifts product ion formation from a charge transfer dominated reaction system to a proton transfer dominated reaction system. For HiKE-IMS operated at high E/N, the reduction in cluster size of reactant ions allows ionization of analytes with low proton affinity even at high relative humidity in the sample gas of RH = 75% at 303.15 K and 1013.25 hPa. In contrast to conventional IMS, where increasing the sample gas humidity inhibits ionization for various analytes, increasing sample gas humidity in HiKE-IMS operated at 120 Td is actually beneficial for ionization yield of most analytes investigated in this work as it increases the number of H3O+(H2O)n.
Collapse
Affiliation(s)
- Christoph Schaefer
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstrasse 9A, 30167 Hannover, Germany
| | - Florian Schlottmann
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstrasse 9A, 30167 Hannover, Germany
| | - Ansgar T Kirk
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstrasse 9A, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstrasse 9A, 30167 Hannover, Germany
| |
Collapse
|
11
|
Haack A, Bissonnette JR, Ieritano C, Hopkins WS. Improved First-Principles Model of Differential Mobility Using Higher Order Two-Temperature Theory. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:535-547. [PMID: 35099948 DOI: 10.1021/jasms.1c00354] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Differential mobility spectrometry is a separation technique that may be applied to a variety of analytes ranging from small molecule drugs to peptides and proteins. Although rudimentary theoretical models of differential mobility exist, these models are often only applied to small molecules and atomic ions without considering the effects of dynamic microsolvation. Here, we advance our theoretical description of differential ion mobility in pure N2 and microsolvating environments by incorporating higher order corrections to two-temperature theory (2TT) and a pseudoequilibrium approach to describe ion-neutral interactions. When comparing theoretical predictions to experimentally measured dispersion plots of over 300 different compounds, we find that higher order corrections to 2TT reduce errors by roughly a factor of 2 when compared to first order. Model predictions are accurate especially for pure N2 environments (mean absolute error of 4 V at SV = 4000 V). For strongly clustering environments, accurate thermochemical corrections for ion-solvent clustering are likely required to reliably predict differential ion mobility behavior. Within our model, general trends associated with clustering strength, solvent vapor concentration, and background gas temperature are well reproduced, and fine structure visible in some dispersion plots is captured. These results provide insight into the dynamic ion-solvent clustering process that underpins the phenomenon of differential ion mobility.
Collapse
Affiliation(s)
- Alexander Haack
- Department of Chemistry, University of Waterloo, 200 University Avenue W, Waterloo, ON N2L 3G1, Canada
| | - Justine R Bissonnette
- Department of Chemistry, University of Waterloo, 200 University Avenue W, Waterloo, ON N2L 3G1, Canada
| | - Christian Ieritano
- Department of Chemistry, University of Waterloo, 200 University Avenue W, Waterloo, ON N2L 3G1, Canada
- Watermine Innovation, Waterloo, Ontario N0B 2T0, Canada
| | - W Scott Hopkins
- Department of Chemistry, University of Waterloo, 200 University Avenue W, Waterloo, ON N2L 3G1, Canada
- Watermine Innovation, Waterloo, Ontario N0B 2T0, Canada
- Centre for Eye and Vision Research, Hong Kong Science Park, New Territories 999077, Hong Kong
| |
Collapse
|
12
|
Schaefer C, Allers M, Kirk AT, Schlottmann F, Zimmermann S. Influence of Reduced Field Strength on Product Ion Formation in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:1810-1820. [PMID: 34170133 DOI: 10.1021/jasms.1c00156] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Classical ion mobility spectrometers (IMS) operated at ambient pressure, often use atmospheric pressure chemical ionization (APCI) sources to ionize organic compounds. In APCI, reactant ions ionize neutral analyte molecules via gas-phase ion-molecule reactions. The positively charged reactant ions in purified, dry air are H3O+, NO+, and O2+•. However, the hydration of reactant ions in classical IMS operated at ambient pressure renders ionization of certain analytes difficult. In contrast to classical IMS operated at ambient pressure, High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) are operated at a decreased pressure of 10-40 mbar, allowing operation at high reduced electric field strengths of up to 120 Td. At such high reduced field strengths, ions reach high effective temperatures causing collision-induced cluster dissociation of the hydrated gas-phase ions, allowing ionization of nonpolar and low proton affinity analytes. The reactant ion population, consisting of H3O+(H2O)n, NO+(H2O)m, and O2+•(H2O)p with an individual abundance that strongly depends on the reduced field strength, differs from the reactant ion population in IMS operated at ambient pressure, which affects the ionization of analyte molecules. In this work, we investigate the influence of reduced field strength on the product ion formation of aromatic hydrocarbons used as model substances. A HiKE-IMS-MS coupling was used to identify the detected ion species. The results show that the analytes form parent cations via charge transfer with NO+(H2O)m and O2+•(H2O)p depending on ionization energy and protonated parent molecules via proton transfer and ligand switching with H3O+(H2O)n mainly depending on proton affinity.
Collapse
Affiliation(s)
- Christoph Schaefer
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Maria Allers
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Ansgar T Kirk
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Florian Schlottmann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| |
Collapse
|
13
|
Allers M, Kirk AT, Schaefer C, Schlottmann F, Zimmermann S. Formation of positive product ions from substances with low proton affinity in high kinetic energy ion mobility spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35:e8998. [PMID: 33140479 DOI: 10.1002/rcm.8998] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Revised: 10/27/2020] [Accepted: 10/30/2020] [Indexed: 06/11/2023]
Affiliation(s)
- Maria Allers
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Hannover, Germany
| | - Ansgar T Kirk
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Hannover, Germany
| | - Christoph Schaefer
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Hannover, Germany
| | - Florian Schlottmann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Hannover, Germany
| | - Stefan Zimmermann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Hannover, Germany
| |
Collapse
|
14
|
Allers M, Kirk AT, Schaefer C, Erdogdu D, Wissdorf W, Benter T, Zimmermann S. Field-Dependent Reduced Ion Mobilities of Positive and Negative Ions in Air and Nitrogen in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:2191-2201. [PMID: 32865400 DOI: 10.1021/jasms.0c00280] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS), ions are formed in a reaction region and separated in a drift region, which is similar to classical drift tube ion mobility spectrometers (IMS) operated at ambient pressure. However, in contrast to the latter, the HiKE-IMS is operated at a decreased background pressure of 10-40 mbar and achieves high reduced electric field strengths of up to 120 Td in both the reaction and the drift region. Thus, the HiKE-IMS allows insights into the chemical kinetics of ion-bound water cluster systems at effective ion temperatures exceeding 1000 K, although it is operated at the low absolute temperature of 45 °C. In this work, a HiKE-IMS with a high resolving power of RP = 140 is used to study the dependence of reduced ion mobilities on the drift gas humidity and the effective ion temperature for the positive reactant ions H3O+(H2O)n, O2+(H2O)n, NO+(H2O)n, NO2+(H2O)n, and NH4+(H2O)n, as well as the negative reactant ions O2-(H2O)n, O3-(H2O)n, CO3-(H2O)n, HCO3-(H2O)n, and NO2-(H2O)n. By varying the reduced electric field strength in the drift region, cluster transitions are observed in the ion mobility spectra. This is demonstrated for the cluster systems H3O+(H2O)n and NO+(H2O)n.
Collapse
Affiliation(s)
- Maria Allers
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstraße 9a, 30167 Hannover, Germany
| | - Ansgar T Kirk
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstraße 9a, 30167 Hannover, Germany
| | - Christoph Schaefer
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstraße 9a, 30167 Hannover, Germany
| | - Duygu Erdogdu
- Department of Physical and Theoretical Chemistry, University of Wuppertal, Gauss Str. 20, 42119 Wuppertal, Germany
| | - Walter Wissdorf
- Department of Physical and Theoretical Chemistry, University of Wuppertal, Gauss Str. 20, 42119 Wuppertal, Germany
| | - Thorsten Benter
- Department of Physical and Theoretical Chemistry, University of Wuppertal, Gauss Str. 20, 42119 Wuppertal, Germany
| | - Stefan Zimmermann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstraße 9a, 30167 Hannover, Germany
| |
Collapse
|
15
|
Schaefer C, Kirk AT, Allers M, Zimmermann S. Ion Mobility Shift of Isotopologues in a High Kinetic Energy Ion Mobility Spectrometer (HiKE-IMS) at Elevated Effective Temperatures. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:2093-2101. [PMID: 32875796 DOI: 10.1021/jasms.0c00220] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Ion mobility spectrometers (IMS) separate ions mainly by ion-neutral collision cross section and to a lesser extent by ion mass and effective temperature. When investigating isotopologues, the difference in collision cross section can be assumed negligible. Since the mobility shift of isotopologues is thus mainly caused by their difference in mass and effective temperature, the investigation of isotopologues can provide important insights into the theory of ion mobility. However, in classical IMS operated at ambient pressure, cluster formation with neutral molecules occurs, which significantly influences the mobility shift of isotopologues and thus makes a sound investigation of the effect of ion mass and effective temperature on the ion mobility difficult. In this work, the relative ion mobility of several organic compounds and their 13C-labeled isotopologues is studied in a High Kinetic Energy Ion Mobility Spectrometer (HiKE-IMS) at high reduced electric fields up to 120 Td, which allows the investigation of nonclustered ion species and thus enables a sound investigation of the mobility shift of isotopologues. The results show that the measured relative ion mobilities of isotopologues having the same effective temperature and, thus, their ion mass dominating the relative ion mobility agree well with theoretical relative ion mobilities predicted by the theory of ion mobility.
Collapse
Affiliation(s)
- Christoph Schaefer
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Appelstr. 9A, 30167 Hannover, Germany
| | - Ansgar T Kirk
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Appelstr. 9A, 30167 Hannover, Germany
| | - Maria Allers
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Appelstr. 9A, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Appelstr. 9A, 30167 Hannover, Germany
| |
Collapse
|
16
|
Allers M, Kirk AT, Timke B, Erdogdu D, Wissdorf W, Benter T, Zimmermann S. Negative Reactant Ion Formation in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:1861-1874. [PMID: 32672039 DOI: 10.1021/jasms.0c00126] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Due to the operation at background pressures between 10-40 mbar and high reduced electric field strengths of up to 120 Td, the ion-molecule reactions in High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) differ from those in classical ambient pressure IMS. In the positive ion polarity mode, the reactant ions H+(H2O)n, O2+(H2O)n, and NO+(H2O)n are observed in the HiKE-IMS. The relative abundances of these reactant ion species significantly depend on the reduced electric field strength in the reaction region, the operating pressure, and the water concentration in the reaction region. In this work, the formation of negative reactant ions in HiKE-IMS is investigated in detail. On the basis of kinetic and thermodynamic data from the literature, the processes resulting in the formation of negative reactant ions are kinetically modeled. To verify the model, we present measurements of the negative reactant ion population in the HiKE-IMS and its dependence on the reduced electric field strength as well as the water and carbon dioxide concentrations in the reaction region. The ion species underlying individual peaks in the ion mobility spectrum are identified by coupling the HiKE-IMS to a time-of-flight mass spectrometer (TOF-MS) using a simple gated interface that enables the transfer of selected peaks of the ion mobility spectrum into the TOF-MS. Both the theoretical model as well as the experimental data suggest the predominant generation of the oxygen-based ions O-, OH-, O2-, and O3- in purified air containing 70 ppmv of water and 30 ppmv of carbon dioxide. Additionally, small amounts of NO2- and CO3- are observed. Their relative abundances highly depend on the reduced electric field strength as well as the water and carbon dioxide concentration. An increase of the water concentration in the reaction region results in the generation of OH- ions, whereas increasing the carbon dioxide concentration favors the generation of CO3- ions, as expected.
Collapse
Affiliation(s)
- Maria Allers
- Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstraße 9a, 30167 Hannover, Germany
| | - Ansgar T Kirk
- Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstraße 9a, 30167 Hannover, Germany
| | - Bennet Timke
- Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstraße 9a, 30167 Hannover, Germany
| | - Duygu Erdogdu
- Department of Physical and Theoretical Chemistry, University of Wuppertal, Gauss Str. 20, 42119 Wuppertal, Germany
| | - Walter Wissdorf
- Department of Physical and Theoretical Chemistry, University of Wuppertal, Gauss Str. 20, 42119 Wuppertal, Germany
| | - Thorsten Benter
- Department of Physical and Theoretical Chemistry, University of Wuppertal, Gauss Str. 20, 42119 Wuppertal, Germany
| | - Stefan Zimmermann
- Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstraße 9a, 30167 Hannover, Germany
| |
Collapse
|