1
|
Lin M, Blevins MS, Sans M, Brodbelt JS, Eberlin LS. Deeper Understanding of Solvent-Based Ambient Ionization Mass Spectrometry: Are Molecular Profiles Primarily Dictated by Extraction Mechanisms? Anal Chem 2022; 94:14734-14744. [PMID: 36228313 DOI: 10.1021/acs.analchem.2c03360] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Solvent-based ambient ionization mass spectrometry (MS) techniques provide a powerful approach for direct chemical analysis and molecular profiling of biological tissues. While molecular profiling of tissues has been widely used for disease diagnosis, little is understood about how the interplay among solvent properties, matrix effects, and ion suppression can influence the detection of biological molecules. Here, we perform a systematic investigation of the extraction processes of lipids using an ambient ionization droplet microsampling platform to investigate how the physicochemical properties of the solvent systems and extraction time influence molecular extraction and detection. Direct molecular profiling and quantitative liquid chromatography-mass spectrometry (LC-MS) of discrete solvent droplets after surface sampling were investigated to provide insights into extraction and ionization mechanisms. The results of this study suggest that intermolecular interactions such as hydrogen bonding play a major role in extraction and detection of lipids using solvent-based ambient ionization techniques. In addition, extraction time was observed to impact the molecular profiles obtained, suggesting optimization of this parameter can be performed to favor detection of specific analytes.
Collapse
Affiliation(s)
- Monica Lin
- Department of Chemistry, The University of Texas at Austin, Austin, Texas78712, United States
| | - Molly S Blevins
- Department of Chemistry, The University of Texas at Austin, Austin, Texas78712, United States
| | - Marta Sans
- Department of Chemistry, The University of Texas at Austin, Austin, Texas78712, United States
| | - Jennifer S Brodbelt
- Department of Chemistry, The University of Texas at Austin, Austin, Texas78712, United States
| | - Livia S Eberlin
- Department of Chemistry, The University of Texas at Austin, Austin, Texas78712, United States.,Department of Surgery, Baylor College of Medicine, Houston, Texas77030, United States
| |
Collapse
|
2
|
McEwen RAH, Hermann M, Metwally H, Donovan K, Liu C, Le Blanc JCY, Covey TR, Oleschuk R. Discontinuously Dewetting Solvent Arrays: Droplet Formation and Poly-Synchronous Surface Extraction for Mass Spectrometry Imaging Applications. Anal Chem 2022; 94:7219-7228. [PMID: 35537093 DOI: 10.1021/acs.analchem.2c00161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
We describe a new liquid tissue stamping method called poly-synchronous surface extraction (PSSE) that utilizes an omniphobic substrate patterned with hydrophilic surface energy traps (SETs), which when wet with a solvent form a dense microdroplet array. When contacted with a tissue sample, each droplet locally extracts analytes from the tissue surface, which subsequentially can be analyzed by matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-IMS) or ambient ionization-MS techniques. Optimization of the patterned surface with six different solvents was carried out to increase the droplet density, height, and reproducibility of volume deposition. Once optimized, sister slices of a strawberry (Fragaria × ananassa) were spatially extracted using the PSSE technique and the chemical distribution of selected compounds was analyzed with both MALDI-IMS and a lower resolution but faster ambient liquid microjunction surface sampling probe (LMJ-SSP) approach. Heat maps for target analytes for the PSSE approach are compared to those produced using traditional MALDI-IMS analysis. The PSSE method aligned well with direct analysis and demonstrated the potential to increase the speed of ambient MS tissue imaging techniques by decreasing the number of steps required for sample preparation.
Collapse
Affiliation(s)
- Rory A H McEwen
- Department of Chemistry, Queen's University, Kingston, Ontario K7L 3N6, Canada
| | - Matthias Hermann
- Department of Chemistry, Queen's University, Kingston, Ontario K7L 3N6, Canada
| | - Haidy Metwally
- Department of Chemistry, Queen's University, Kingston, Ontario K7L 3N6, Canada
| | - Katherine Donovan
- Department of Chemistry, Queen's University, Kingston, Ontario K7L 3N6, Canada
| | - Chang Liu
- SCIEX, Concord, Ontario L4K 4V8, Canada
| | | | | | - Richard Oleschuk
- Department of Chemistry, Queen's University, Kingston, Ontario K7L 3N6, Canada
| |
Collapse
|
3
|
Abstract
The areas of application of modern bioanalytical chromatography–mass spectrometry are so extensive that any attempt to systematize them becomes subjective. It would be more correct to say that there is no such area of biology and medicine where chromatography–mass spectrometry would not find application. This article focuses on the areas of application of this technique that are either relatively new or insufficiently covered in recent reviews. State-of-the-art bioanalytical techniques have become multitargeted in terms of analytes and standardized in terms of matrices. The ability to detect trace concentrations of analytes in the presence of a huge number of biomatrix macrocomponents using chromatography–mass spectrometry is especially important for bioanalytical chemistry. In the target-oriented determination of persistent organic pollutants by chromatography–mass spectrometry, the main problem is the expansion of the list of analytes, including isomers. In the detection of exposures to unstable toxicants, the fragmented adducts of xenobiotics with biomolecules become target biomarkers along with hydrolytic metabolites. The exposome reflects the general exposure of a human being to total xenobiotics and the metabolic status reflects the physiological state of the body. Chromatography–mass spectrometry is a key technique in metabolomics. Metabolomics is currently used to solve the problems of clinical diagnostics and anti-doping control. Biological sample preparation procedures for instrumental analysis are being simplified and developed toward increasing versatility. Proteomic technologies with the use of various versions of mass spectrometry have found application in the development of new methods for diagnosing coronavirus infections.
Collapse
Affiliation(s)
- E. I. Savelieva
- Research Institute of Hygiene, Occupational Pathology, and Human Ecology, Federal Medical Biological Agency, 188663 pos. Kuz’molovskii, Vsevolozhskii region, Leningrad oblast Russia
| |
Collapse
|
4
|
Walton CL, Kertesz V, Cahill JF. Design and Evaluation of a Tethered, Open Port Sampling Interface for Liquid Extraction-Mass Spectrometry Chemical Analysis. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:198-205. [PMID: 33180483 DOI: 10.1021/jasms.0c00268] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Presented is a tethered, liquid-extraction-sampling interface designed for the mass spectrometric surface sampling/analysis of 3D objects. The tethered, open port sampling interface (TOPSI) incorporates a vacuum line between the sampling probe and ionization source, which enables the ability for an extended, tethered sample transfer line. Herein, several designs of the hand-held TOPSI are presented and evaluated on the basis of the analytical metrics of analyte transport time, peak width, and analyte sensitivity. The best analytical metrics were obtained with capillary flow resistances arranged in a particular order and the vacuum region set at 6.2 kPa. This TOPSI design incorporated a transfer capillary 1 m in length, while retaining a fast analyte transport time (12 s), short signal peak width (5 s baseline-to-baseline), and high analyte signal at 90% of that obtained with a regular open port sampling interface (OPSI). The hand-held TOPSI was demonstrated for the characterization of extracted small molecules and metabolites from the surface of mint and rosemary leaves.
Collapse
Affiliation(s)
- Courtney L Walton
- Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6131, United States
| | - Vilmos Kertesz
- Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6131, United States
| | - John F Cahill
- Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6131, United States
| |
Collapse
|
5
|
Li YL, Zhou BW, Cheng J, Zhang F, Zhang J, Zhang L, Guo YL. Mass Spectrometry-Based Discovery of New Chemical Scaffold Rearrangement Ions: Aza-biphenylene as a Novel Potent Biradical Agent in Cancer Chemotherapy. Anal Chem 2020; 92:14517-14527. [PMID: 33054169 DOI: 10.1021/acs.analchem.0c02669] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Discovery of a new drug is time-consuming, laborious, and expensive. Herein, a novel integrative strategy for discovering potential new lead compounds has been developed, which was based on the characteristics of mass spectrometry (MS). MS was used to predict the potential forced degradation products (DPs) and metabolites of drugs by electrospray ionization and collision-induced dissociation (CID). Special rearrangement ions representing unique predicted DPs and metabolites were identified. The consistency between the predicted and the measured results was proven by in vitro metabolism and forced degradation of a commercial drug, respectively. From this, new chemical scaffold rearrangement ions named (aza)-biphenylenes, as potent anticancer agents, were discovered. As a representative aza-biphenylene analogue, 2-azabiphenylene was proven in vitro to induce apoptosis and inhibit the growth of various human cancer cells in a dose-dependent manner. Surprisingly, 2-azabiphenylene exhibited the best comparable bioactivity with the positive control sorafenib, but showed significantly lower in vitro cytotoxicity than sorafenib (at least a 5-fold decrease in cytotoxicity) because it could be targeted to the tumor microenvironment at low pH. A biradical mechanism accompanied by a mitochondrion-dependent oxidative stress mechanism was proposed to explore its anticancer mechanism. The highly reactive intermediate aza-biphenylenediyl worked as an active pharmaceutical ingredient and induced apoptosis of cancer cells. This provided the basis for the potential applications of CID-induced special rearrangement ions in developing new lead compounds.
Collapse
Affiliation(s)
- Yu-Ling Li
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China
| | - Bo-Wen Zhou
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China
| | - Jie Cheng
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China
| | - Fang Zhang
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China
| | - Jing Zhang
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China
| | - Li Zhang
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China
| | - Yin-Long Guo
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China
| |
Collapse
|