Monopoli A, Nacci A, Cataldi TRI, Calvano CD. Synthesis and Matrix Properties of α-Cyano-5-phenyl-2,4-pentadienic Acid (CPPA) for Intact Proteins Analysis by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry. Molecules 2020; 25:molecules25246054. [PMID: 33371472 PMCID: PMC7767571 DOI: 10.3390/molecules25246054] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 12/14/2020] [Accepted: 12/15/2020] [Indexed: 01/06/2023] Open
Abstract
The effectiveness of a synthesized matrix, α-cyano-5-phenyl-2,4-pentadienic acid (CPPA), for protein analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) in complex samples such as foodstuff and bacterial extracts, is demonstrated. Ultraviolet (UV) absorption along with laser desorption/ionization mass spectrometry (LDI-MS) experiments were systematically conducted in positive ion mode under standard Nd:YLF laser excitation with the aim of characterizing the matrix in terms of wavelength absorption and proton affinity. Besides, the results for standard proteins revealed that CPPA significantly enhanced the protein signals, reduced the spot-to-spot variability and increased the spot homogeneity. The CPPA matrix was successful employed to investigate intact microorganisms, milk and seed extracts for protein profiling. Compared to conventional matrices such as sinapinic acid (SA), α-cyano-4-hydroxycinnamic acid (CHCA) and 4-chloro-α-cyanocinnamic acid (CClCA), CPPA exhibited better signal-to-noise (S/N) ratios and a uniform response for most examined proteins occurring in milk, hazelnut and in intact bacterial cells of E. coli. These findings not only provide a reactive proton transfer MALDI matrix with excellent reproducibility and sensitivity, but also contribute to extending the battery of useful matrices for intact protein analysis.
Collapse
Affiliation(s)
- Antonio Monopoli
- Agenzia delle Dogane e dei Monopoli, Ufficio delle Dogane di Bari, Corso De Tullio, 70122 Bari, Italy;
| | - Angelo Nacci
- Dipartimento di Chimica, Università degli Studi di Bari Aldo Moro, Via Orabona, 70126 Bari, Italy; (A.N.); (T.R.I.C.)
| | - Tommaso R. I. Cataldi
- Dipartimento di Chimica, Università degli Studi di Bari Aldo Moro, Via Orabona, 70126 Bari, Italy; (A.N.); (T.R.I.C.)
- Centro Interdipartimentale di Ricerca S.M.A.R.T., 70126 Bari, Italy
| | - Cosima D. Calvano
- Centro Interdipartimentale di Ricerca S.M.A.R.T., 70126 Bari, Italy
- Dipartimento di Farmacia-Scienze del Farmaco, Università degli Studi di Bari Aldo Moro, Via Orabona, 70126 Bari, Italy
- Correspondence:
| |
Collapse
|
2
|
The properties of the polyethylene glycol complex PEG(Na+)(Cu+) on the copper electrodeposited layer by Time-of-Flight Secondary-Ion Mass Spectrometry. The new insights. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.135931] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
3
|
Organic matrices, ionic liquids, and organic matrices@nanoparticles assisted laser desorption/ionization mass spectrometry. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2017.01.012] [Citation(s) in RCA: 58] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
4
|
Hosseini S, Martinez-Chapa SO. Principles and Mechanism of MALDI-ToF-MS Analysis. FUNDAMENTALS OF MALDI-TOF-MS ANALYSIS 2017. [DOI: 10.1007/978-981-10-2356-9_1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
5
|
Gopal J, Lee CH, Wu HF. Rapid and direct detection of Invivo kinetics of pathogenic bacterial infection from mouse blood and urine. J Proteomics 2011; 75:2972-82. [PMID: 22193515 DOI: 10.1016/j.jprot.2011.12.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2011] [Revised: 11/29/2011] [Accepted: 12/01/2011] [Indexed: 12/29/2022]
Abstract
This study demonstrates the first use of matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) to trace the Invivo infection kinetics of the well known deadly pathogen Staphylococcus aureus in Swiss albino mice. The growth curve of the bacteria from the point of injection (200μL of bacterial suspension (10(8)cfu/mL)) into the mouse blood till mortality (death) was periodically analyzed using the plate counting method and MALDI-MS. Bacterial counts of 10(3)cfu/mL were observed in the log phase of the growth curve in the blood and 10(2)cfu/mL were observed in the urine samples. Death occurred in the log phase of the growth curve, where the bacterial counts showed steady increase. In other cases, the bacteria counts started decreasing after 48h and by 96h the bacteria got totally eliminated from the mouse and these mice survived. Direct MALDI-MS was not feasible for tracking the bacteria in the infected blood. However, ionic liquid 1-Butyl-3-methylimidazolium tetrafluoroborate was successful in enabling bacterial detection amidst the strong blood peaks. But, in the case of the urine analysis, it was observed that direct MALDI-MS was adequate to enable detection. The results obtained prove the efficacy of MALDI-MS for analyzing pathogenic bacteria in clinical samples. This article is part of a Special Issue entitled: Proteomics: The clinical link.
Collapse
Affiliation(s)
- Judy Gopal
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, 70, Lien-Hai Road, Kaohsiung, 80424, Taiwan
| | | | | |
Collapse
|
6
|
Yang H, Wang J, Song F, Zhou Y, Liu S. Isoliquiritigenin (4,2',4'-trihydroxychalcone): a new matrix-assisted laser desorption/ionization matrix with outstanding properties for the analysis of neutral oligosaccharides. Anal Chim Acta 2011; 701:45-51. [PMID: 21763807 DOI: 10.1016/j.aca.2011.05.051] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2011] [Revised: 05/30/2011] [Accepted: 05/31/2011] [Indexed: 10/18/2022]
Abstract
A novel matrix of isoliquiritigenin (ISL), a flavonoid with a chalcone structure (4,2',4'-trihydroxychalcone), was demonstrated to be advantageous in the analysis of neutral oligosaccharides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). With ISL as a matrix, adequate signal for an analyte can be obtained in much lower matrix concentrations and laser intensity compared to commonly used MALDI matrices. Four different sample preparation methods were tested, and the dried droplet method exhibited the best performance on MALDI-TOF-MS analysis of oligosaccharides with ISL as a matrix. For the analysis of carbohydrates, compared with popular matrices such as 2,5-dihydroxybenzoic acid (DHB) and 2,4,6-trihydroxyacetophenone (THAP), ISL exhibited outstanding matrix properties as follows: (1) higher homogeneity of crystallization thus allowing automatic data acquisition, (2) better spectral quality in terms of resolution and signal to noise ratio (SN(-1)), (3) better salt tolerance, (4) higher sensitivity, and (5) enough fragmentation yield to use LIFT-TOF/TOF MS to get richer structural information. In addition, reliable quantitative analysis of oligosaccharides with a good linearity over two concentration orders (1-100 pmol μL(-1)) and good reproducibility of the signal intensity (RSD less than 15%) were achieved using this matrix. These results give a new outlook on high-speed analysis of neutral carbohydrates by MALDI-TOF MS.
Collapse
Affiliation(s)
- Hongmei Yang
- Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, China
| | | | | | | | | |
Collapse
|
7
|
Tseng MC, Obena R, Lu YW, Lin PC, Lin PY, Yen YS, Lin JT, Huang LD, Lu KL, Lai LL, Lin CC, Chen YJ. Dihydrobenzoic acid modified nanoparticle as a MALDI-TOF MS matrix for soft ionization and structure determination of small molecules with diverse structures. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2010; 21:1930-1939. [PMID: 20739189 DOI: 10.1016/j.jasms.2010.08.001] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2010] [Revised: 07/27/2010] [Accepted: 08/01/2010] [Indexed: 05/29/2023]
Abstract
Efficient structural characterization is important for quality control when developing novel materials. In this study, we demonstrated the soft ionization capability of the hybrid of immobilized silica and 2,5-dihydrobenzoic acid (DHB) on iron oxide magnetic nanoparticles in MALDI-TOF MS with a clean background. The ratio between SiO(2) and DHB was examined and was found to affect the surface immobilization of DHB on the nanoparticle, critically controlling the ionization efficiency and interference background. Compared with commercial DHB, the functionalized nanoparticle-assisted MALDI-TOF MS provided superior soft ionization with production of strong molecular ions within 5 ppm mass accuracy on a variety of new types of synthetic materials used for solar cells, light emitting devices, dendrimers, and glycolipids, including analytes with either thermally labile structures or poor protonation tendencies. In addition, the enhancements of the molecular ion signal also provided high-quality product-ion spectra allowing structural characterization and unambiguous small molecule identification. Using this technique, the structural differences among the isomers were distinguished through their characteristic fragment ions and comprehensive fragmentation patterns. With the advantages of long-term stability and simple sample preparation by deposition on a regular sample plate, the use of DHB-functionalized nanoparticles combined with high-resolution MALDI-TOF MS provides a generic platform for rapid and unambiguous structure determination of small molecules.
Collapse
|
8
|
Ionic liquids in analytical chemistry. Anal Chim Acta 2010; 661:1-16. [DOI: 10.1016/j.aca.2009.12.007] [Citation(s) in RCA: 587] [Impact Index Per Article: 41.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2009] [Revised: 12/04/2009] [Accepted: 12/09/2009] [Indexed: 11/23/2022]
|
9
|
Togashi H, Kobayashi Y. Effects of substrate surfaces in matrix-assisted laser desorption/ionization mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2009; 23:2952-2958. [PMID: 19681097 DOI: 10.1002/rcm.4210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
For matrix-assisted laser desorption/ionization (MALDI) mass spectra, undesirable ion contamination can occur due to the direct laser excitation of substrate materials (i.e., laser desorption/ionization (LDI)) if the samples do not completely cover the substrate surfaces. In this study, comparison is made of LDI processes on substrates of indium and silver, which easily emit their own ions upon laser irradiation, and conventional materials, stainless steel and gold. A simultaneous decrease of ion intensities with the number of laser pulses is observed as a common feature. By the application of an indium substrate to the MALDI mass spectrometry of alkali salts and alkylammonium salts mixed with matrices, 2,5-dihydroxybenzoic acid (DHB) or N-(4-methoxybenzylidene)-4-butylaniline (MBBA), the mixing of LDI processes can be detected by the presence of indium ions in the mass spectra. This method has also been found to be useful for investigating the intrinsic properties of the MALDI matrices: DHB samples show an increase in the abundance of fragment ions of matrix molecules and cesium ions with the number of laser pulses irradiating the same sample spot; MBBA samples reveal a decrease in the level of background noise with an increase in the thickness of the sample layer.
Collapse
Affiliation(s)
- Hisashi Togashi
- National Metrology Institute of Japan (NMIJ), AIST, Tsukuba Central 5, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565; Japan.
| | | |
Collapse
|
10
|
Langley GJ, Herniman JM, Townell MS. 2B or not 2B, that is the question: further investigations into the use of pencil as a matrix for matrix-assisted laser desorption/ionisation. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:180-90. [PMID: 17171774 DOI: 10.1002/rcm.2827] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
The effective use of pencil as a matrix for matrix-assisted laser desorption/ionisation (MALDI) for the study of actinides has previously been demonstrated (Black et al., Rapid Commun. Mass Spectrom. 2006; 20: 1053). Here, the scope of the types of molecules amenable to analysis by this method has been extended, establishing that approximately 90% of a library containing 50 diverse small molecules can be successfully analysed by this technique. Further, the role played by the bulk materials present in the different pencil leads has been investigated and a simple one-step deposition of matrix and calibration materials has been achieved through the fabrication of different calibration pencils (Cali-Pens).
Collapse
Affiliation(s)
- G John Langley
- School of Chemistry, University of Southampton, Southampton SO17 1BJ, UK.
| | | | | |
Collapse
|
11
|
Wilkes JG, Buzatu DA, Dare DJ, Dragan YP, Chiarelli MP, Holland RD, Beaudoin M, Heinze TM, Nayak R, Shvartsburg AA. Improved cell typing by charge-state deconvolution of matrix-assisted laser desorption/ionization mass spectra. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2006; 20:1595-603. [PMID: 16628570 DOI: 10.1002/rcm.2475] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Robust, specific, and rapid identification of toxic strains of bacteria and viruses, to guide the mitigation of their adverse health effects and optimum implementation of other response actions, remains a major analytical challenge. This need has driven the development of methods for classification of microorganisms using mass spectrometry, particularly matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), that allows high-throughput analyses with minimum sample preparation. We describe a novel approach to cell typing based on pattern recognition of MALDI mass spectra, which involves charge-state deconvolution in conjunction with a new correlation analysis procedure. The method is applicable to both prokaryotic and eukaryotic cells. Charge-state deconvolution improves the quantitative reproducibility of spectra because multiply charged ions resulting from the same biomarker attaching a different number of protons are recognized and their abundances are combined. This allows a clearer distinction of bacterial strains or of cancerous and normal liver cells. Improved class distinction provided by charge-state deconvolution was demonstrated by cluster spacing on canonical variate score charts and by correlation analyses. Deconvolution may enhance detection of early disease state or therapy progress markers in various tissues analyzed by MALDI-MS.
Collapse
Affiliation(s)
- Jon G Wilkes
- National Center for Toxicological Research, FDA, 3900 NCTR Road, Jefferson, AR 72079, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Cramer R, Corless S. Liquid ultraviolet matrix-assisted laser desorption/ionization - mass spectrometry for automated proteomic analysis. Proteomics 2005; 5:360-70. [PMID: 15627960 DOI: 10.1002/pmic.200400956] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
We have combined several key sample preparation steps for the use of a liquid matrix system to provide high analytical sensitivity in automated ultraviolet -- matrix-assisted laser desorption/ionisation -- mass spectrometry (UV-MALDI-MS). This new sample preparation protocol employs a matrix-mixture which is based on the glycerol matrix-mixture described by Sze et al. The low-femtomole sensitivity that is achievable with this new preparation protocol enables proteomic analysis of protein digests comparable to solid-state matrix systems. For automated data acquisition and analysis, the MALDI performance of this liquid matrix surpasses the conventional solid-state MALDI matrices. Besides the inherent general advantages of liquid samples for automated sample preparation and data acquisition the use of the presented liquid matrix significantly reduces the extent of unspecific ion signals in peptide mass fingerprints compared to typically used solid matrices, such as 2,5-dihydroxybenzoic acid (DHB) or alpha-cyano-hydroxycinnamic acid (CHCA). In particular, matrix and low-mass ion signals and ion signals resulting from cation adduct formation are dramatically reduced. Consequently, the confidence level of protein identification by peptide mass mapping of in-solution and in-gel digests is generally higher.
Collapse
|
13
|
Turney K, Harrison WW. Liquid supports for ultraviolet atmospheric pressure matrix-assisted laser desorption/ionization. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2004; 18:629-635. [PMID: 15052573 DOI: 10.1002/rcm.1379] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Atmospheric pressure (AP) liquid matrices for ultraviolet (UV) matrix-assisted laser desorption/ionization (MALDI) are presented. Doping a known organic chromophore, alpha-cyano-4-hydroxycinnamic acid (CHCA), into liquid media yielded a homogenous sample system with simplified sample preparation, increased sample lifetime, and added utility for APMALDI ion sources. Compared with vacuum situations, AP matrices are not as limited by vapor pressure, so liquid matrix formulations can focus on desorption and ionization versus vacuum stability and source contamination. The parameters studied include chromophore concentration, liquid support variations, and quantitation capability. Chromophore concentration adjustments provided insight into the necessary absorbance for UV-APMALDI and demonstrated the importance of laser penetration depth. Liquid support variations allowed adjustments of sample lifetime and analyte solvents. Extended sample lifetime is beneficial for instrument tuning and source optimization; however, increased liquid viscosity lowers signal intensity. The shot-to-shot reproducibility, as examined with individual ion packets, suggests that the liquid matrix can alleviate some inconsistencies seen with solid MALDI, suggesting a possibility for better quantitation. The measurements for laser penetration depth, solution viscosity, and solvent additives could add to the information on MALDI mechanisms. The liquid matrix offers advantages that complement current MALDI methods.
Collapse
Affiliation(s)
- Kevin Turney
- Department of Chemistry, University of Florida, P.O. Box 117200, Gainesville, FL 32611-7200, USA
| | | |
Collapse
|
14
|
Williams JB, Chapman TM, Hercules DM. Matrix-assisted laser desorption/ionization mass spectrometry of discrete mass poly(butylene glutarate) oligomers. Anal Chem 2003; 75:3092-100. [PMID: 12964756 DOI: 10.1021/ac030061q] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The mass dependency of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) response has been studied using equimolar mixtures of synthetic discrete mass poly(butylene glutarate) (PBG) oligomers of known structure having degrees of polymerization of 8, 16, 32, and 64. Mass discrimination observed was attributed to choice of matrix and detector saturation caused by higher laser intensity and inclusion of matrix ions in the MALDI spectra. Optimization of sample preparation and instrumental parameters provided uniform response over the mass ranged spanned by these four oligomers. The oligomer mixture was shown to serve as a model of more complex polymer distributions in the mass range 780-6000 Da, and application of the discrete mass oligomers as internal and calibration standards was demonstrated. Inclusion of PBG discrete mass oligomers as an internal standard in a quasi-equimolar mixture with polydispersed poly(butylene adipate) (PBA) indicated that some diminution of response occurred during the analysis of this mixture of materials. Reasons for differences in the corrected molecular weight averages of the polydispersed PBA obtained from measurements using MALDI and GPC were studied using individual discrete mass oligomers as calibration standards for GPC. The data indicated that differences in hydrodynamic volumes of PBG oligomers and PEG standards at similar masses resulted in an overestimation by GPC of the molecular weight averages of the PBA distribution.
Collapse
Affiliation(s)
- John B Williams
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, USA
| | | | | |
Collapse
|
15
|
Marie A, Alves S, Fournier F, Tabet JC. Fluorinated matrix approach for the characterization of hydrophobic perfluoropolyethers by matrix-assisted laser desorption/ionization time-of-flight MS. Anal Chem 2003; 75:1294-9. [PMID: 12659188 DOI: 10.1021/ac0260802] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Characterization of fluorinated polymers in MALDI is often unsuccessful because commonly used matrixes, such as 2,5-dihydroxybenzoic acid, Indole acrylic acid, alpha-cyano-4-hydroxycinnamic acid, etc., do not desorb/ionize fluorinated polymers efficiently. This could be in part attributed to the unfavorable interaction between the matrix molecules and fluorinated oligomers due to differences in their hydrophobicities. Moreover, the relative cation affinity between the matrix molecules and the fluorinated oligomers may not favor the gas-phase cationization process of the fluorinated oligomers. To overcome these limitations, fluorinated derivates of benzoic acid (pentafluorobenzoic acid) and cinnamic acid (Pentafluoro cinnamic acid) were employed for the desorption/ionization of perfluoropolyethers. Presence of fluorine atoms in the matrix might improve the interaction between the matrix and perfluoroether during the crystallization or ionization step. With a pentafluorobenzoic acid matrix, intact silver cationized oligomers were desorbed, whereas with a pentafluorocinnamic acid matrix, loss of end group was observed. This loss could be rationalized by the dissociation of the silver cationized oligomers via an ion-dipole mechanism. This work shows the possibility of characterizing yet another important class of fluorinated polymer by MALDI-TOFMS.
Collapse
Affiliation(s)
- A Marie
- Laboratoire de Chimie Structurale Organique et Biologique, CNRS UMR 7613, Université Pierre et Marie Curie, Courier 45, 4 place Jussieu, 75252 Paris Cedex 05, France
| | | | | | | |
Collapse
|
16
|
Robins C, Limbach PA. The use of nonpolar matrices for matrix-assisted laser desorption/ionization mass spectrometric analysis of high boiling crude oil fractions. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2003; 17:2839-2845. [PMID: 14673835 DOI: 10.1002/rcm.1275] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) with nonpolar matrices has been investigated for its applicability to the characterization of atmospheric resid crude oil fractions. The data obtained by use of nonpolar matrices was compared with that from polar matrices as well as from direct LDI-MS and field ionization mass spectrometry. Nonpolar matrices, such as anthracene or 9-cyanoanthracene, yield only a single radical molecular cation upon LDI. Thus, no interfering matrix-related ions are present during the MALDI-TOFMS analysis of the crude oil sample. Nonpolar matrices yield molecular mass distributions from linear mode MALDI-TOFMS that are comparable to distributions found with LDI-MS. An advantage of nonpolar matrices is the increased production of analyte ions, which allows reflectron mode MALDI-TOFMS to be performed. Nonpolar matrices are also shown to be less sensitive to solvent and sample preparation conditions than conventional polar matrices. These results suggest that nonpolar matrices may be favorable alternatives to more traditional polar or acidic matrices commonly used in the MALDI mass spectral characterization of crude oil related samples.
Collapse
Affiliation(s)
- Chad Robins
- Rieveschl Laboratories for Mass Spectrometry, Department of Chemistry, P.O. Box 210172, University of Cincinnati, Cincinnati, OH 45221, USA
| | | |
Collapse
|
17
|
Falkenhagen J, Jancke H, Krüger RP, Rikowski E, Schulz G. Characterization of silsesquioxanes by size-exclusion chromatography and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2003; 17:285-290. [PMID: 12569437 DOI: 10.1002/rcm.911] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Liquid chromatography in combination with spectroscopic methods like matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) or nuclear magnetic resonance (NMR) spectroscopy is a powerful method to characterize silsesquioxanes and silsesquioxane mixtures. As new examples, the formation of silsesquioxyl-substituted silsesquioxanes [(n-octyl)(7)(SiO(1.5))(8)](2)O and [(n-octyl)(7)(SiO(1.5))(8)O](2)[(n-octyl)(6)(SiO(1.5))(8)] as well as the cage rearrangement of octa-[(n-heptyl)silsesquioxane] to larger structures [(n-heptyl)SiO(1.5))](n) up to n=28 are shown.
Collapse
Affiliation(s)
- Jana Falkenhagen
- Bundesanstalt für Materialforschung und -prüfung, Unter den Eichen 87, 12205 Berlin, Germany
| | | | | | | | | |
Collapse
|
18
|
Bauer BJ, Guttman CM, Liu DW, Blair WR. Tri-alpha-naphthylbenzene as a crystalline or glassy matrix for matrix-assisted laser desorption/ionization: a model system for the study of effects of dispersion of polymer samples at a molecular level. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2002; 16:1192-1198. [PMID: 12112271 DOI: 10.1002/rcm.699] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Tri-alpha-naphthylbenzene (TalphaNB) can exist as either a crystalline or glassy solid at ambient temperatures, making it a unique matrix in matrix-assisted laser desorption/ionization (MALDI) spectroscopy. Electrosprayed TalphaNB is crystalline and has a melting point of 180 +/- 2 degrees C, as measured by differential scanning calorimetry (DSC). A glass of TalphaNB is obtained upon heating above the crystalline melting point with a glass transition temperature of 68 +/- 2 degrees C having no remaining crystallinity. MALDI samples containing mass fraction 1% polystyrene (PS) are run in both the crystalline and amorphous states. In the crystalline state, there is a strong spectrum typical of PS, but upon melting and quenching to the glassy state, the MALDI signal disappears. If the transparent, amorphous sample is treated with 1-butanol, it becomes white, and the MALDI signal returns. DSC shows that the 1-butanol treatment leads to the return of some of the crystallinity. Small angle neutron scattering (SANS) shows that the crystalline state has large aggregations of PS while the amorphous state has molecularly dispersed PS molecules. MALDI gives strong signals only when there are large aggregations of polymer molecules, with individually dispersed molecules producing no signal.
Collapse
Affiliation(s)
- Barry J Bauer
- National Institute of Standards and Technology, 100 Bureau Dr., Stop 8541, Gaithersburg, MD 20899-8541, USA.
| | | | | | | |
Collapse
|
19
|
Affiliation(s)
- Xia Dong
- Department of Chemistry, Vanderbilt University, Box 1822 Station B, Nashville, Tennessee 37235
| | - David M. Hercules
- Department of Chemistry, Vanderbilt University, Box 1822 Station B, Nashville, Tennessee 37235
| |
Collapse
|
20
|
Characterization of synthetic polymers by MALDI-TOF/MS: investigation into new methods of sample target preparation and consequence on mass spectrum finger print. Anal Chem 2000; 72:5106-14. [PMID: 11055735 DOI: 10.1021/ac000124u] [Citation(s) in RCA: 77] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Characterization of synthetic polymers by Matrix assisted laser desorption (MALDI) is limited by the solubility of different oligomers in a suitable solvent, and the fingerprint of the mass spectrum is affected by the properties of solvents employed (eg., pH, secondary solvents, evaporation) during sample target preparation. If solvents are not used during sample target preparation, then solvent properties should not play an important role in determining the quality of the MALDI mass spectrum. We report here two solventless approaches for sample target preparation. It was observed that Poly(ethylene glycol) 6000 (PEG) showed the same molecular mass distribution in different modes of sample target preparation. Fluorinated polymer used in these studies was affected by sample target preparation protocol and by target surface. Pyrolysis of PEG oligomers was observed in all the methods of sample target preparation. The desorbed high mass neutral oligomers fragment to give small oligomers which are then cationized by the desolvation of the cationized matrix clusters. Moreover, the origin of the matrix clusters (i.e., formed in the condensed phase or in the gas phase) determines the relative intensities of PEG oligomers cationized by sodium or potassium.
Collapse
|
21
|
He M, He J, Mi Q, Zhou Q. Characterization of mesogen-jacketed liquid crystalline polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2000; 14:1806-1812. [PMID: 11006589 DOI: 10.1002/1097-0231(20001015)14:19<1806::aid-rcm97>3.0.co;2-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
For synthetic polymers, a proper sample preparation method is essential for successful characterization by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. In this work, six synthetic mesogen-jacketed liquid crystalline polymers (MJLCPs) with different main-chain, spacer and mesogenic units were investigated by MALDI-TOF mass spectrometry. Several factors that affect the analysis of these polymers were examined. These factors include matrices used, cationization salts used, the concentration of polymers, and the ratio of sample to matrix. After testing different conditions, we found a suitable sample preparation method for these six polymers. The number average molecular weight (M(n)), weight average molecular weight (M(w)) and polydispersity (PD) were calculated using data obtained in the linear mode. The end groups of the polymers were proposed using data obtained in reflectron mode. Copyright 2000 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- M He
- Department of Chemistry, Peking University, Beijing 100871, China
| | | | | | | |
Collapse
|
22
|
Rashidzadeh H, Guo B. Use of MALDI-TOF to measure molecular weight distributions of polydisperse poly(methyl methacrylate). Anal Chem 1998; 70:131-5. [PMID: 9435471 DOI: 10.1021/ac970568z] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The main problem encountered in the MALDI-TOF analysis of polydisperse polymers is mass discrimination against high-mass oligomers. This work investigated some of the causes of this problem by using PMMAs as the polymer analytes. It was found that both instrumental and matrix factors could lead to this problem. Among the instrumental factors, detector saturation resulting from strong signals of matrix-related and low-mass oligomer ions can be a potential major cause of this problem. Since most of the ion detectors do not have an adequate dynamic range to avoid saturation, detection saturation could be a fundamental limitation, especially when the molar ratio of high- to low-mass oligomers is small. A quantitative analysis was also performed to examine the matrix effect. IAA and HABA were selected for this study. It was found that mass discrimination occurred in both cases, but the use of HABA led to more profound mass discrimination. This shows that the use of improper matrixes could be another source causing mass discrimination. Hence, unless new approaches are developed, one must be cautious in using MALDI-TOF for directly measuring MWDs of polydisperse polymers, especially those highly polydisperse polymers.
Collapse
Affiliation(s)
- H Rashidzadeh
- Department of Chemistry, Cleveland State University, Ohio 44115, USA
| | | |
Collapse
|
23
|
MALDI FTMS analysis of polymers: improved performance using an open ended cylindrical analyzer cell. ACTA ACUST UNITED AC 1997. [DOI: 10.1016/s0168-1176(97)00229-2] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
24
|
Williams JB, Gusev AI, Hercules DM. Characterization of Polyesters by Matrix-Assisted Laser Desorption Ionization Mass Spectrometry. Macromolecules 1997. [DOI: 10.1021/ma970123c] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- John B. Williams
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260
| | - Arkady I. Gusev
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260
| | - David M. Hercules
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260
| |
Collapse
|