Application of nanocomposite polymer hydrogels for ultra-sensitive fluorescence detection of proteins in gel electrophoresis. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2017.05.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
2
|
Beneito-Cambra M, Anres P, Vial J, Gareil P, Delaunay N. Stability and effectiveness of linear polyacrylamide capillary coating to suppress EOF in acidic media in the presence of surfactants, ionic liquids and organic modifiers. Talanta 2016; 150:546-52. [DOI: 10.1016/j.talanta.2015.12.070] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2015] [Revised: 12/22/2015] [Accepted: 12/26/2015] [Indexed: 11/25/2022]
|
3
|
Chung M, Kim D, Herr AE. Polymer sieving matrices in microanalytical electrophoresis. Analyst 2014; 139:5635-54. [DOI: 10.1039/c4an01179a] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
4
|
Aydoğan C, Çetin K, Denizli A. Novel tentacle-type polymer stationary phase grafted with anion exchange polymer chains for open tubular CEC of nucleosides and proteins. Analyst 2014; 139:3790-5. [DOI: 10.1039/c3an01897k] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
5
|
Lu JJ, Wang S, Li G, Wang W, Pu Q, Liu S. Chip-capillary hybrid device for automated transfer of sample preseparated by capillary isoelectric focusing to parallel capillary gel electrophoresis for two-dimensional protein separation. Anal Chem 2012; 84:7001-7. [PMID: 22830584 PMCID: PMC3437655 DOI: 10.1021/ac3017168] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
In this article, we introduce a chip-capillary hybrid device to integrate capillary isoelectric focusing (CIEF) with parallel capillary sodium dodecyl sulfate- polyacrylamide gel electrophoresis (SDS-PAGE) or capillary gel electrophoresis (CGE) toward automating two-dimensional (2D) protein separations. The hybrid device consists of three chips that are butted together. The middle chip can be moved between two positions to reroute the fluidic paths, which enables the performance of CIEF and injection of proteins partially resolved by CIEF to CGE capillaries for parallel CGE separations in a continuous and automated fashion. Capillaries are attached to the other two chips to facilitate CIEF and CGE separations and to extend the effective lengths of CGE columns. Specifically, we illustrate the working principle of the hybrid device, develop protocols for producing and preparing the hybrid device, and demonstrate the feasibility of using this hybrid device for automated injection of CIEF-separated sample to parallel CGE for 2D protein separations. Potentials and problems associated with the hybrid device are also discussed.
Collapse
Affiliation(s)
- Joann J. Lu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, OK 73019, USA
| | - Shili Wang
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, OK 73019, USA
| | - Guanbin Li
- School of Petrochemical Engineering, Lanzhou University of Technology, Lanzhou, Gansu, 730050, P.R. China
| | - Wei Wang
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, OK 73019, USA
| | - Qiaosheng Pu
- Department of Chemistry, Lanzhou University, Lanzhou, Gansu, 730000, P.R. China
| | - Shaorong Liu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, OK 73019, USA
| |
Collapse
|
6
|
Zhu Z, Lu JJ, Liu S. Protein separation by capillary gel electrophoresis: a review. Anal Chim Acta 2012; 709:21-31. [PMID: 22122927 PMCID: PMC3227876 DOI: 10.1016/j.aca.2011.10.022] [Citation(s) in RCA: 132] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2011] [Revised: 10/02/2011] [Accepted: 10/07/2011] [Indexed: 12/13/2022]
Abstract
Capillary gel electrophoresis (CGE) has been used for protein separation for more than two decades. Due to the technology advancement, current CGE methods are becoming more and more robust and reliable for protein analysis, and some of the methods have been routinely used for the analysis of protein-based pharmaceuticals and quality controls. In light of this progress, we survey 147 papers related to CGE separations of proteins and present an overview of this technology. We first introduce briefly the early development of CGE. We then review the methodology, in which we specifically describe the matrices, coatings, and detection strategies used in CGE. CGE using microfabricated channels and incorporation of CGE with two-dimensional protein separations are also discussed in this section. We finally present a few representative applications of CGE for separating proteins in real-world samples.
Collapse
Affiliation(s)
- Zaifang Zhu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, OK 73019
| | - Joann J. Lu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, OK 73019
| | - Shaorong Liu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, OK 73019
| |
Collapse
|
7
|
Lu JJ, Zhu Z, Wang W, Liu S. Coupling sodium dodecyl sulfate-capillary polyacrylamide gel electrophoresis with matrix-assisted laser desorption ionization time-of-flight mass spectrometry via a poly(tetrafluoroethylene) membrane. Anal Chem 2011; 83:1784-90. [PMID: 21309548 DOI: 10.1021/ac103148k] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Sodium dodecyl sulfate (SDS)-polyacrylamide gel electrophoresis (PAGE) is a fundamental analytical technique for proteomic research, and SDS-capillary gel electrophoresis (CGE) is its miniaturized version. Compared to conventional slab-gel electrophoresis, SDS-CGE has many advantages such as increased separation efficiency, reduced separation time, and automated operation. SDS-CGE is not widely accepted in proteomic research primarily due to the difficulties in identifying the well-resolved proteins. MALDI-TOF-MS is an outstanding platform for protein identifications. Coupling the two would solve the problem but is extremely challenging because the MS detector has no access to the SDS-CGE-resolved proteins and the SDS interferes with MS detection. In this work we introduce an approach to address these issues. We discover that poly(tetrafluoroethylene) (PTFE) membranes are excellent materials for collecting SDS-CGE-separated proteins. We demonstrate that we can wash off the SDS bound to the collected proteins and identify these proteins on-membrane with MALDI-TOF-MS. We also show that we can immunoblot and Coomassie-stain the proteins collected on these membranes.
Collapse
Affiliation(s)
- Joann J Lu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, Oklahoma 73019, United States
| | | | | | | |
Collapse
|
8
|
|
9
|
Cao J, Tan Y, Che Y, Ma Q. Fabrication and properties of superabsorbent complex gel beads composed of hydrolyzed polyacrylamide and chitosan. J Appl Polym Sci 2010. [DOI: 10.1002/app.31796] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
10
|
Liu Q, Li Y, Yang Y, Yao S. Separation of acidic and basic proteins by capillary electrophoresis using gemini surfactants and gemini-capped nanoparticles as buffer additives. ACTA ACUST UNITED AC 2009. [DOI: 10.1007/s11426-009-0166-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
11
|
Xu L, Dong XY, Sun Y. Electroosmotic pump-assisted capillary electrophoresis of proteins. J Chromatogr A 2009; 1216:6071-6. [DOI: 10.1016/j.chroma.2009.06.032] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2009] [Revised: 06/05/2009] [Accepted: 06/08/2009] [Indexed: 11/29/2022]
|
12
|
Liu Q, Yang Y, Huang Y, Pan C, Nie Z, Yao S. Separation of acidic and basic proteins by CE with CTAB additive and its applications in peptide and protein profiling. Electrophoresis 2009; 30:2151-8. [DOI: 10.1002/elps.200800785] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
13
|
Yang S, Liu J, Lee CS, Devoe DL. Microfluidic 2-D PAGE using multifunctional in situ polyacrylamide gels and discontinuous buffers. LAB ON A CHIP 2009; 9:592-599. [PMID: 19190795 DOI: 10.1039/b805541f] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
A two-dimensional microfluidic system is presented for intact protein separations combining isoelectric focusing (IEF) and sodium dodecyl sulfate (SDS) polyacrylamide gel electrophoresis (PAGE) employing in situ photopolymerized polyacrylamide (PAAm) gels. The PAAm gels are used for multiple functions. In addition to serving as a highly-resolving separation medium for gel electrophoresis, discrete polyacrylamide gel plugs are used to enable the efficient isolation of different on-chip media including anolyte, catholyte, and sample/ampholyte solutions for IEF. The gel plugs are demonstrated as on-chip reagent containers, holding defined quantities of SDS for on-chip SDS-protein complexation, and enabling the use of a discontinuous buffer system for sample band sharpening during SDS-PAGE. The 2-D chip also employs several unique design features including an angled isoelectric focusing channel to minimize sample tailing, and backbiasing channels designed to achieve uniform interdimensional sample transfer. Separation results using E. coli cell lysate are presented using a 10-channel chip with and without the discontinuous buffer system, with resolving power more than doubled in the former case. Further improvements in separation resolution are demonstrated using a 20-channel chip design.
Collapse
Affiliation(s)
- Shuang Yang
- Department of Mechanical Engineering, University of Maryland, College Park, College Park, Maryland 20742, USA
| | | | | | | |
Collapse
|
14
|
Zhou J, Xu J, Xie Y, Qu F, Deng Y, Geng L. Semi-crosslinked polyacrylamides as high-resolution and dynamic self-coating sieving matrices for protein capillary electrophoresis. Sci Bull (Beijing) 2008. [DOI: 10.1007/s11434-008-0430-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
15
|
Lin CY, Liu CH, Chang HC, Tseng WL. Enrichment and separation of acidic and basic proteins using the centrifugal ultrafiltration followed by nanoparticle-filled capillary electrophoresis. Electrophoresis 2008; 29:3024-31. [DOI: 10.1002/elps.200700879] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
16
|
Yu CJ, Chang HC, Tseng WL. On-line concentration of proteins by SDS-CGE with LIF detection. Electrophoresis 2008; 29:483-90. [DOI: 10.1002/elps.200700217] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
17
|
Wu S, Lu JJ, Wang S, Peck KL, Li G, Liu S. Staining method for protein analysis by capillary gel electrophoresis. Anal Chem 2007; 79:7727-33. [PMID: 17874848 PMCID: PMC2753390 DOI: 10.1021/ac071055n] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A novel staining method and the associated fluorescent dye were developed for protein analysis by capillary SDS-PAGE. The method strategy is to synthesize a pseudo-SDS dye and use it to replace some of the SDS in SDS-protein complexes so that the protein can be fluorescently detected. The pseudo-SDS dye consists of a long, straight alkyl chain connected to a negative charged fluorescent head and binds to proteins just as SDS. The number of dye molecules incorporated with a protein depends on the dye concentration relative to SDS in the sample solution, since SDS and dye bind to proteins competitively. In this work, we synthesized a series of pseudo-SDS dyes, and tested their performances for capillary SDS-PAGE. FT-16 (a fluorescein molecule linked with a hexadodecyl group) seemed to be the best among all the dyes tested. Although the numbers of dye molecules bound to proteins (and the fluorescence signals from these protein complexes) were maximized in the absence of SDS, high-quality separations were obtained when co-complexes of SDS-protein-dye were formed. The migration time correlates well with protein size even after some of the SDS in the SDS-protein complexes was replaced by the pseudo-SDS dye. Under optimized experimental conditions and using a laser-induced fluorescence detector, limits of detection of as low as 0.13 ng/mL (bovine serum albumin) and dynamic ranges over 5 orders of magnitude in which fluorescence response is proportional to the square root of analyte concentration were obtained. The method and dye were also tested for separations of real-world samples from E. coli.
Collapse
Affiliation(s)
| | | | | | | | | | - Shaorong Liu
- Corresponding author. Fax: 806 742 1289, E-mail:
| |
Collapse
|
18
|
Lu JJ, Pu Q, Wang S, Liu S. A cam-based laser-induced fluorescence scanner for capillary array electrophoresis. Anal Chim Acta 2007; 590:98-103. [PMID: 17416228 DOI: 10.1016/j.aca.2007.03.034] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2006] [Revised: 02/17/2007] [Accepted: 03/13/2007] [Indexed: 11/20/2022]
Abstract
Capillary array electrophoresis (CAE) is an important high throughput analytical technique. Laser-induced fluorescence (LIF) has been the dominant detection method for CAE owing to its low limit of detection (LOD) and wide linear dynamic range (LDR). Linear LIF scanners were first used in CAE because linear motions of an objective match well with a common planar array of capillaries. A problem with linear scanners is that the motor is required accelerating/decelerating so that all capillaries can be properly scanned, which makes motion control complicated and reduces the duty cycle. Rotary scanners were developed to overcome this problem. While rotary scanners have been successfully applied in CAE, the capillaries have to be arranged in a circular format, which can be inconvenient in some cases. In this report, we describe a cam-based LIF scanner as an alternative technique for CAE detection. In this system, a rotary motor is mechanically linked with a capillary holder via a cam. During operation, the motor carries the cam in a rotary motion that drives an array of capillaries on the holder to move back and forth across the objective for fluorescence detection. Using this design, the capillaries can be parallel-arranged in a plane while the motor acceleration/deceleration is avoided. To demonstrate the feasibility of this approach, we constructed a prototype instrument with a constant-velocity scanning distance of approximately 10 mm, a scanning frequency of 3 Hz and a duty cycle of approximately 70%. The scanner exhibited a LOD of 69 pM of fluorescein and a LDR of 3.5 orders of magnitude. Multiplexed capillary SDS-PAGE was performed on this scanner for protein separations.
Collapse
Affiliation(s)
- Joann J Lu
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX 79409, United States
| | | | | | | |
Collapse
|
19
|
Lu JJ, Liu S. A robust cross-linked polyacrylamide coating for microchip electrophoresis of dsDNA fragments. Electrophoresis 2006; 27:3764-71. [PMID: 16960840 DOI: 10.1002/elps.200600201] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Surface derivatization plays an important role in microchip electrophoresis. It not only enhances the resolution, but also improves the reproducibility. So far, the most popularly used derivatization method for glass microchannels is to covalently attach a layer of linear polyacrylamide (LPA) to the channel surfaces. However, LPA coating has two problems: incomplete coverage and limited lifetime. To address these issues, we have recently developed a cross-linked polyacrylamide (CPA) derivatization protocol and demonstrated it for high-resolution protein separations by CIEF, CGE, and CZE. In this report, we used this protocol to coat microchip channels and exhibited the reliability and robustness of CPA coating for microchip electrophoresis of DNA molecules. dsDNA fragments were used as our test samples. High resolutions were obtained for fragments ranging from 100 bp to 10 kpb. After more than 800 runs, the CPA-coated microchannels still performed well and comparable resolutions were maintained throughout these runs.
Collapse
Affiliation(s)
- Joann J Lu
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, USA
| | | |
Collapse
|
20
|
Huang YF, Huang CC, Hu CC, Chang HT. Capillary electrophoresis-based separation techniques for the analysis of proteins. Electrophoresis 2006; 27:3503-22. [PMID: 16927348 DOI: 10.1002/elps.200600100] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
CE offers the advantages of high speed, great efficiency, as well as the requirement of minimum amounts of sample and buffer for the analysis of proteins. In this review, we summarize the CE-based techniques coupled with absorption, LIF, and MS detection systems for the analysis of proteins mostly within the past 5 years. The basic principle of each technique and its advantages and disadvantages for protein analysis are discussed in brief. Advanced CE techniques, including on-column concentration techniques and high-efficiency multidimensional separation techniques, for high-throughput protein profiling of complex biological samples and/or of single cells are emphasized. Although the developed techniques provide improved peak capacity, they have not become practical tools for proteomics, mainly because of poor reproducibility, low-sample lading capacity, and low throughput due to ineffective interfaces between two separation dimensions and that between separation and MS systems. In order to identify the complexities and dynamics of the proteomes expressed by cells, tissues, or organisms, techniques providing improved analytical sensitivity, throughput, and dynamic ranges are still demanded.
Collapse
Affiliation(s)
- Yu-Fen Huang
- Department of Chemistry, National Taiwan University, Taipei, Taiwan
| | | | | | | |
Collapse
|
21
|
Das C, Fan ZH. Effects of separation length and voltage on isoelectric focusing in a plastic microfluidic device. Electrophoresis 2006; 27:3619-26. [PMID: 16915565 DOI: 10.1002/elps.200600013] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
This paper describes the investigation on the effects of separation length and voltage on IEF in a plastic microfluidic device. A LIF, whole-channel imaging detection (WCID) system was developed to monitor proteins while they were moving under an electric field. IEF was carried out in a separation medium consisting of carrier ampholytes and a mixture of linear polymers (hydroxyethylcellulose and hydroxypropylcellulose). We found that the IEF separation resolution is essentially independent of separation length when the same voltage is applied, which agrees with the theory. This result supports the notion that IEF in a microfabricated device leads to more rapid analysis without sacrificing the resolving power. A higher separation voltage also brought about more rapid analysis and superior separation resolution. IEF of two proteins (green fluorescence protein and R-phycoerythrin) was achieved in 1.5 min when 500 V was applied across a 1.9-cm channel. We found that a linear relationship exists between the focusing time and the inverse of the electrical field strength. In addition, we confirmed the phenomenon in which the pH gradient was compressed to the middle of a channel, and we found that the relative amount of the gradient compression decreased with the channel length.
Collapse
Affiliation(s)
- Champak Das
- Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL 32611, USA
| | | |
Collapse
|