1
|
Dewey C, Kaplan DI, Fendorf S, Boiteau RM. Quantitative Separation of Unknown Organic-Metal Complexes by Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry. Anal Chem 2023; 95:7960-7967. [PMID: 37163723 DOI: 10.1021/acs.analchem.3c00696] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Dissolved organic matter (DOM) is widely recognized to control the solubility and reactivity of trace metals in the environment. However, the mechanisms that govern metal-DOM complexation remain elusive, primarily due to the analytical challenge of fractionating and quantifying metal-organic species within the complex mixture of organic compounds that comprise DOM. Here, we describe a quantitative method for fractionation and element-specific detection of organic-metal complexes using liquid chromatography with online inductively coupled plasma mass spectrometry (LC-ICP-MS). The method implements a post-column compensation gradient to stabilize ICP-MS elemental response across the LC solvent gradient, thereby overcoming a major barrier to achieving quantitative accuracy with LC-ICP-MS. With external calibration and internal standard correction, the method yields concentrations of organic-metal complexes that were consistently within 6% of their true values, regardless of the complex's elution time. We used the method to evaluate the effects of four stationary phases (C18, phenyl, amide, and pentafluoroylphenyl propyl) on the recovery and separation of environmentally relevant trace metals (Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in Suwannee River Fulvic Acid and Suwannee River Natural Organic Matter. The C18, amide, and phenyl phases generally yielded optimal metal recoveries (>75% for all metals except Pb), with the phenyl phase separating polar species to a greater extent than C18 or amide. We also fractionated organic-bound Fe, Cu, and Ni in oxidized and reduced soils, revealing divergent metal-DOM speciation across soil redox environments. By enabling quantitative fractionation of DOM-bound metals, our method offers a means for advancing a mechanistic understanding of metal-organic complexation throughout the environment.
Collapse
Affiliation(s)
- Christian Dewey
- College of Earth, Ocean, & Atmospheric Sciences, Oregon State University, Corvallis, Oregon, 97331, United States
- Department of Earth System Science, Stanford University, Stanford, California, 94305, United States
| | - Daniel I Kaplan
- Savannah River Ecology Laboratory, University of Georgia, Aiken, South Carolina, 29802, United States
| | - Scott Fendorf
- Department of Earth System Science, Stanford University, Stanford, California, 94305, United States
| | - Rene M Boiteau
- College of Earth, Ocean, & Atmospheric Sciences, Oregon State University, Corvallis, Oregon, 97331, United States
| |
Collapse
|
2
|
Nosti AJ, Barrio LC, Calderón-Celis F, Soldado A, Encinar JR. Absolute quantification of proteins using element mass spectrometry and generic standards. J Proteomics 2022; 256:104499. [DOI: 10.1016/j.jprot.2022.104499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Accepted: 01/21/2022] [Indexed: 10/19/2022]
|
3
|
Calderón-Celis F, Encinar JR, Sanz-Medel A. Standardization approaches in absolute quantitative proteomics with mass spectrometry. MASS SPECTROMETRY REVIEWS 2018; 37:715-737. [PMID: 28758227 DOI: 10.1002/mas.21542] [Citation(s) in RCA: 97] [Impact Index Per Article: 16.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2017] [Accepted: 06/20/2017] [Indexed: 05/10/2023]
Abstract
Mass spectrometry-based approaches have enabled important breakthroughs in quantitative proteomics in the last decades. This development is reflected in the better quantitative assessment of protein levels as well as to understand post-translational modifications and protein complexes and networks. Nowadays, the focus of quantitative proteomics shifted from the relative determination of proteins (ie, differential expression between two or more cellular states) to absolute quantity determination, required for a more-thorough characterization of biological models and comprehension of the proteome dynamism, as well as for the search and validation of novel protein biomarkers. However, the physico-chemical environment of the analyte species affects strongly the ionization efficiency in most mass spectrometry (MS) types, which thereby require the use of specially designed standardization approaches to provide absolute quantifications. Most common of such approaches nowadays include (i) the use of stable isotope-labeled peptide standards, isotopologues to the target proteotypic peptides expected after tryptic digestion of the target protein; (ii) use of stable isotope-labeled protein standards to compensate for sample preparation, sample loss, and proteolysis steps; (iii) isobaric reagents, which after fragmentation in the MS/MS analysis provide a final detectable mass shift, can be used to tag both analyte and standard samples; (iv) label-free approaches in which the absolute quantitative data are not obtained through the use of any kind of labeling, but from computational normalization of the raw data and adequate standards; (v) elemental mass spectrometry-based workflows able to provide directly absolute quantification of peptides/proteins that contain an ICP-detectable element. A critical insight from the Analytical Chemistry perspective of the different standardization approaches and their combinations used so far for absolute quantitative MS-based (molecular and elemental) proteomics is provided in this review.
Collapse
Affiliation(s)
| | - Jorge Ruiz Encinar
- Department of Physical and Analytical Chemistry, University of Oviedo, Oviedo, Spain
| | - Alfredo Sanz-Medel
- Department of Physical and Analytical Chemistry, University of Oviedo, Oviedo, Spain
| |
Collapse
|
4
|
Lehmann WD. A timeline of stable isotopes and mass spectrometry in the life sciences. MASS SPECTROMETRY REVIEWS 2017; 36:58-85. [PMID: 26919394 DOI: 10.1002/mas.21497] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2015] [Accepted: 01/21/2016] [Indexed: 06/05/2023]
Abstract
This review retraces the role of stable isotopes and mass spectrometry in the life sciences. The timeline is divided into four segments covering the years 1920-1950, 1950-1980, 1980-2000, and 2000 until today. For each period methodic progress and typical applications are discussed. Application of stable isotopes is driven by improvements of mass spectrometry, chromatography, and related fields in sensitivity, mass accuracy, structural specificity, complex sample handling ability, data output, and data evaluation. We currently experience the vision of omics-type analyses, that is, the comprehensive identification and quantification of a complete compound class within one or a few analytical runs. This development is driven by stable isotopes without competition by radioisotopes. In metabolic studies as classic field of isotopic tracer experiments, stable isotopes and radioisotopes were competing solutions, with stable isotopes as the long-term junior partner. Since the 1990s the number of metabolic studies with radioisotopes decreases, whereas stable isotope studies retain their slow but stable upward tendency. Unique fields of stable isotopes are metabolic tests in newborns, metabolic experiments in healthy controls, newborn screening for inborn errors, quantification of drugs and drug metabolites in doping control, natural isotope fractionation in geology, ecology, food authentication, or doping control, and more recently the field of quantitative omics-type analyses. There, cells or whole organisms are systematically labeled with stable isotopes to study proteomic differences or specific responses to stimuli or genetic manipulation. The duo of stable isotopes and mass spectrometry will probably continue to grow in the life sciences, since it delivers reference-quality quantitative data with molecular specificity, often combined with informative isotope effects. © 2016 Wiley Periodicals, Inc. Mass Spec Rev 36:58-85, 2017.
Collapse
Affiliation(s)
- Wolf D Lehmann
- German Cancer Research Center (DKFZ), D-69120 Heidelberg, Germany
| |
Collapse
|
5
|
Maes E, Tirez K, Baggerman G, Valkenborg D, Schoofs L, Encinar JR, Mertens I. The use of elemental mass spectrometry in phosphoproteomic applications. MASS SPECTROMETRY REVIEWS 2016; 35:350-360. [PMID: 25139451 DOI: 10.1002/mas.21440] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2013] [Revised: 05/14/2014] [Accepted: 05/14/2014] [Indexed: 06/03/2023]
Abstract
Reversible phosphorylation is one of the most important post-translational modifications in mammalian cells. Because this molecular switch is an important mechanism that diversifies and regulates proteins in cellular processes, knowledge about the extent and quantity of phosphorylation is very important to understand the complex cellular interplay. Although phosphoproteomics strategies are applied worldwide, they mainly include only molecular mass spectrometry (like MALDI or ESI)-based experiments. Although identification and relative quantification of phosphopeptides is straightforward with these techniques, absolute quantification is more complex and usually requires for specific isotopically phosphopeptide standards. However, the use of elemental mass spectrometry, and in particular inductively coupled plasma mass spectrometry (ICP-MS), in phosphoproteomics-based experiments, allow one to absolutely quantify phosphopeptides. Here, these phosphoproteomic applications with ICP-MS as elemental detector are reviewed. Pioneering work and recent developments in the field are both described. Additionally, the advantage of the parallel use of molecular and elemental mass spectrometry is stressed.
Collapse
Affiliation(s)
- Evelyne Maes
- Flemish Institute for Technological Research (VITO), Mol, Belgium
- KU Leuven, Research Group of Functional Genomics and Proteomics, Leuven, Belgium
| | - Kristof Tirez
- Flemish Institute for Technological Research (VITO), Mol, Belgium
| | - Geert Baggerman
- Flemish Institute for Technological Research (VITO), Mol, Belgium
- CFP-CeProMa, University of Antwerp, Antwerp, Belgium
| | - Dirk Valkenborg
- Flemish Institute for Technological Research (VITO), Mol, Belgium
- CFP-CeProMa, University of Antwerp, Antwerp, Belgium
- Interuniversity Institute for Biostatistics and Statistical Bioinformatics, Hasselt University, Diepenbeek, Belgium
| | - Liliane Schoofs
- KU Leuven, Research Group of Functional Genomics and Proteomics, Leuven, Belgium
| | - Jorge Ruiz Encinar
- Department of Physical and Analytical Chemistry, University of Oviedo, Oviedo, Spain
| | - Inge Mertens
- Flemish Institute for Technological Research (VITO), Mol, Belgium
- CFP-CeProMa, University of Antwerp, Antwerp, Belgium
| |
Collapse
|
6
|
Abstract
Antibody-free approaches for quantitative LC–MS/MS-based protein bioanalysis are reviewed and critically evaluated, and compared with the more widely used immunoaffinity-based approaches. Antibody-free workflows will be divided into four groups and discussed in the following order: direct analysis of signature peptides after proteolytic digestion; enrichment of target proteins and signature peptides by fractionated protein precipitation; enrichment of target proteins and signature peptides by reversed-phase and ion-exchange solid-phase extraction; and enrichment of target proteins and signature peptides by (antibody-free) affinity-solid-phase extraction.
Collapse
|
7
|
Safian MF, Lehmann WD. Microquantification of inorganic and organic phosphate by negative ion electrospray tandem mass spectrometry. Anal Bioanal Chem 2015; 407:2933-7. [DOI: 10.1007/s00216-015-8542-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2014] [Revised: 02/03/2015] [Accepted: 02/06/2015] [Indexed: 11/25/2022]
|
8
|
Hann S, Dernovics M, Koellensperger G. Elemental analysis in biotechnology. Curr Opin Biotechnol 2015; 31:93-100. [DOI: 10.1016/j.copbio.2014.08.008] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2014] [Accepted: 08/23/2014] [Indexed: 01/25/2023]
|
9
|
Maes E, Brusten W, Beutels F, Baggerman G, Mertens I, Valkenborg D, Landuyt B, Schoofs L, Tirez K. The benefits and limitations of reaction cell and sector field inductively coupled plasma mass spectrometry in the detection and quantification of phosphopeptides. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2015; 29:35-44. [PMID: 25462361 DOI: 10.1002/rcm.7079] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2014] [Revised: 10/16/2014] [Accepted: 10/16/2014] [Indexed: 06/04/2023]
Abstract
RATIONALE The phosphorylation of proteins is one of the most important post-translational modifications in nature. Knowledge of the quantity or degree of protein phosphorylation in biological samples is extremely important. A combination of liquid chromatography (LC) and inductively coupled plasma mass spectrometry (ICP-MS) allows the absolute and relative quantification of the phosphorus signal. METHODS A comparison between dynamic reaction cell quadrupole ICP-MS (DRC-Q-ICP-MS) and high-resolution sector field ICP-MS (SF-ICP-MS) in detecting signals of phosphorus-containing species using identical capillary LC (reversed-phase technology) and nebulizer settings was performed. RESULTS A method to diminish the reversed-phase gradient-related signal instability in phosphorus detection with LC/ICP-MS applications was developed. Bis(4-nitrophenyl)phosphate (BNPP) was used as a standard to compare signal-to-noise ratios and limits of detection (LODs) between the two instrumental setups. The LOD reaches a value of 0.8 µg L(-1) when applying the DRC technology in Q-ICP-MS and an LOD of 0.09 µg L(-1) was found with the SF-ICP-MS setup. This BNPP standard was further used to compare the absolute quantification possibilities of phosphopeptides in these two setups. CONCLUSIONS This one-to-one comparison of two interference-reducing ICP-MS instruments demonstrates that absolute quantification of individual LC-separated phosphopeptides is possible. However, based on the LOD values, SF-ICP-MS has a higher sensitivity in detecting phosphorus signals and thus is preferred in phosphopeptide analysis.
Collapse
Affiliation(s)
- Evelyne Maes
- Flemish Institute for Technological Research (VITO), Mol, Belgium; CFP-CeProMa, University of Antwerp, Antwerp, Belgium; KU Leuven, Research Group of Functional Genomics and Proteomics, Leuven, Belgium
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Evaluation of online carbon isotope dilution mass spectrometry for the purity assessment of synthetic peptide standards. Anal Chim Acta 2014; 844:48-53. [DOI: 10.1016/j.aca.2014.07.041] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2014] [Revised: 07/24/2014] [Accepted: 07/29/2014] [Indexed: 11/16/2022]
|
11
|
Boehm ME, Hahn B, Lehmann WD. One-source peptide/phosphopeptide ratio standards for accurate and site-specific determination of the degree of phosphorylation. Methods Mol Biol 2014; 1156:367-78. [PMID: 24792001 DOI: 10.1007/978-1-4939-0685-7_24] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Reversible protein phosphorylation is a key mediator for intracellular signal transduction. Here we describe an innovative method for the production of pairs of peptide standards designed for quantitative mass spectrometry. These standard pairs can be used for site-specific analysis of the degree of phosphorylation of proteins in a bottom-up approach. The method starts from an isotopically labeled phosphopeptide analogue of the analyte phosphopeptide and ends up with a labeled peptide/phosphopeptide ratio standard in which the molar ratio between the phosphorylated and the unphosphorylated form is exactly defined. The signals of the ratio standard are used to standardize the corresponding analyte signals. This compensates for differences in LC recovery or ionization efficiency between the phosphorylated and unphosphorylated forms. The method can also be extended to quantitative analysis of multisite phosphorylation in a single peptide, which is exemplified for the presence of two phosphorylation sites. Peptide/phosphopeptide ratio standards exhibit high ratio accuracy, since ratio adjustment is performed by volumetric operations only.
Collapse
Affiliation(s)
- Martin E Boehm
- Molecular Structure Analysis, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| | | | | |
Collapse
|
12
|
Preparation of heteroelement-incorporated and stable isotope-labeled protein standards for quantitative proteomics. Methods Mol Biol 2014; 1156:337-63. [PMID: 24792000 DOI: 10.1007/978-1-4939-0685-7_23] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
A major obstacle for further development of quantitative proteomics is the lack of accurately quantified protein standards. The following protocol describes innovative methods for the production of stable isotope-labeled protein standards. Their production is achieved by cell-free protein synthesis, which enables simultaneous incorporation of selenomethionine and stable isotope-labeled amino acids. The selenium tag allows sensitive and accurate quantification by inductively coupled plasma mass spectrometry (ICP-MS). The stable isotope label allows internal standardization in mass spectrometry-based proteomics by electrospray ionization-tandem mass spectrometry (ESI-MS/MS). Both label types can be placed within a single protein RISQ standard (recombinant isotope-labeled and selenium quantified) or can be distributed over two types of related RSQ and RIQ standards for the same target protein (recombinant selenium quantified and recombinant isotope-labeled and quantified). The combination of cell-free synthesis as production method with ICP-MS and ESI-MS/MS as detection methods results in protein standards, which are quantified at an outstanding level of accuracy.
Collapse
|
13
|
Inductively coupled plasma-MS in drug development: bioanalytical aspects and applications. Bioanalysis 2013; 4:1933-65. [PMID: 22943623 DOI: 10.4155/bio.12.141] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
The vast majority of today's modern bioanalytical methods for pharmacokinetic, pharmacodynamic and immunogenicity purposes are based on LC-MS/MS and immunoanalytical approaches. Indeed, these methodologies are suitable for a wide range of molecules from small to large. For a smaller but not insignificant group of compounds, LC-MS/MS is not suitable - or in some cases much less suitable - as a reliable bioanalytical methodology, and inductively coupled plasma (ICP)-MS is a more appropriate methodology. ICP-MS is one of these less widely used techniques in drug development. This methodology is predominantly used for elemental bioanalysis for pharmacokinetics, for imaging purposes, for mass-balance, food-effect and biomarker studies. In addition, in the last couple of years an increasing number of applications has been published, where ICP-MS and its various hyphenations (LC-ICP-MS, CE-ICP-MS) have been used for speciation/metabolism and proteomics studies. Here, the analytical potential, the quantitative bioanalytical aspects, the various modes of operation and the challenges of the application of ICP-MS in life sciences applications are given. This includes an overview of recent applications in this area in scientific literature, the various hyphenation possibilities and their application areas and the analysis of the various sample matrices applicable to these fields. It also provides a brief outlook of where the potential of this technique lies in the future of regulated bioanalysis and drug development.
Collapse
|
14
|
Boehm ME, Seidler J, Hahn B, Lehmann WD. Site-specific degree of phosphorylation in proteins measured by liquid chromatography-electrospray mass spectrometry. Proteomics 2012; 12:2167-78. [PMID: 22653803 DOI: 10.1002/pmic.201100561] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
This review focuses on quantitative protein phosphorylation analysis based on coverage of both the phosphorylated and nonphosphorylated forms. In this way, site-specific data on the degree of phosphorylation can be measured, generating the most detailed level of phosphorylation status analysis of proteins. To highlight the experimental challenges in this type of quantitative protein phosphorylation analysis, we discuss the typical workflows for mass spectrometry-based proteomics with a focus on the quantitative analysis of peptide/phosphopeptide ratios. We review workflows for measuring site-specific degrees of phosphorylation including the label-free approach, differential stable isotope labeling of analytes, and methods based on the addition of stable isotope labeled peptide/phosphopeptide pairs as internal standards. The discussion also includes the determination of phosphopeptide isoform abundance data for multiply phosphorylated motifs that contain information about the connectivity of phosphorylation events. The review closes with a prospective on the use of intact stable isotope labeled proteins as internal standards and a summarizing discussion of the typical accuracies of the individual methods.
Collapse
Affiliation(s)
- Martin E Boehm
- Molecular Structure Analysis, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | | | | | | |
Collapse
|
15
|
Winter D, Hung CW, Jaskolla TW, Karas M, Lehmann WD. Enzyme-cleavable tandem peptides for quantitative studies in MS-based proteomics. Proteomics 2012; 12:3470-4. [DOI: 10.1002/pmic.201200290] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2012] [Revised: 09/13/2012] [Accepted: 10/01/2012] [Indexed: 11/09/2022]
Affiliation(s)
- Dominic Winter
- Molecular Structure Analysis; German Cancer Research Center; Heidelberg; Germany
| | - Chien-Wen Hung
- Molecular Structure Analysis; German Cancer Research Center; Heidelberg; Germany
| | - Thorsten W. Jaskolla
- Cluster of Excellence Macromolecular Complexes; Institute of Pharmaceutical Chemistry; Goethe-University Frankfurt; Frankfurt; Germany
| | - Michael Karas
- Cluster of Excellence Macromolecular Complexes; Institute of Pharmaceutical Chemistry; Goethe-University Frankfurt; Frankfurt; Germany
| | - Wolf D. Lehmann
- Molecular Structure Analysis; German Cancer Research Center; Heidelberg; Germany
| |
Collapse
|
16
|
Sanz-Medel A, Montes-Bayón M, Bettmer J, Luisa Fernández-Sanchez M, Ruiz Encinar J. ICP-MS for absolute quantification of proteins for heteroatom-tagged, targeted proteomics. Trends Analyt Chem 2012. [DOI: 10.1016/j.trac.2012.07.020] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
17
|
Pröfrock D, Prange A. Inductively coupled plasma-mass spectrometry (ICP-MS) for quantitative analysis in environmental and life sciences: a review of challenges, solutions, and trends. APPLIED SPECTROSCOPY 2012; 66:843-68. [PMID: 22800465 DOI: 10.1366/12-06681] [Citation(s) in RCA: 142] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
This focal point review provides an overview of recent developments and capabilities of inductively coupled plasma mass spectrometry (ICP-MS) coupled with different separation techniques for applications in the fields of quantitative environmental and bio-analysis. Over the past years numerous technical improvements, which are highlighted in this review, have helped to promote the evolution of ICP-MS to one of the most versatile tools for elemental quantification. In particular, the benefits and possibilities of using state-of-the-art hyphenated ICP-MS approaches for quantitative analysis are demonstrated with a focus on environmental and bio-analytical applications.
Collapse
Affiliation(s)
- Daniel Pröfrock
- Helmholtz Zentrum Geesthacht-Zentrum für Material und Küstenforschung, Department Marine Bioanalytical Chemistry, Max-Planck Str. 1, 21502 Geesthacht, Germany.
| | | |
Collapse
|
18
|
Bantscheff M, Lemeer S, Savitski MM, Kuster B. Quantitative mass spectrometry in proteomics: critical review update from 2007 to the present. Anal Bioanal Chem 2012; 404:939-65. [PMID: 22772140 DOI: 10.1007/s00216-012-6203-4] [Citation(s) in RCA: 539] [Impact Index Per Article: 44.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2012] [Revised: 06/06/2012] [Accepted: 06/15/2012] [Indexed: 02/08/2023]
Abstract
Mass-spectrometry-based proteomics is continuing to make major contributions to the discovery of fundamental biological processes and, more recently, has also developed into an assay platform capable of measuring hundreds to thousands of proteins in any biological system. The field has progressed at an amazing rate over the past five years in terms of technology as well as the breadth and depth of applications in all areas of the life sciences. Some of the technical approaches that were at an experimental stage back then are considered the gold standard today, and the community is learning to come to grips with the volume and complexity of the data generated. The revolution in DNA/RNA sequencing technology extends the reach of proteomic research to practically any species, and the notion that mass spectrometry has the potential to eventually retire the western blot is no longer in the realm of science fiction. In this review, we focus on the major technical and conceptual developments since 2007 and illustrate these by important recent applications.
Collapse
|
19
|
Schwarz G, Beck S, Weller MG, Linscheid MW. Comparison of the fragmentation behavior of differentially metal-coded affinity tag (MeCAT)-labeled peptides. JOURNAL OF MASS SPECTROMETRY : JMS 2012; 47:885-889. [PMID: 22791256 DOI: 10.1002/jms.3036] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
|
20
|
Fernández SD, Sugishama N, Encinar JR, Sanz-Medel A. Triple Quad ICPMS (ICPQQQ) as a New Tool for Absolute Quantitative Proteomics and Phosphoproteomics. Anal Chem 2012; 84:5851-7. [DOI: 10.1021/ac3009516] [Citation(s) in RCA: 135] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Affiliation(s)
- Silvia Diez Fernández
- Department of Physical and Analytical
Chemistry, University of Oviedo, Julián
Clavería 8, 33006 Oviedo, Spain
| | - Naoki Sugishama
- Agilent Technologies International Japan, Ltd., 9-1 Takakura-cho, Hachioji-shi,
Tokyo, 192-0033, Japan
| | - Jorge Ruiz Encinar
- Department of Physical and Analytical
Chemistry, University of Oviedo, Julián
Clavería 8, 33006 Oviedo, Spain
| | - Alfredo Sanz-Medel
- Department of Physical and Analytical
Chemistry, University of Oviedo, Julián
Clavería 8, 33006 Oviedo, Spain
| |
Collapse
|
21
|
Catron B, Caruso JA, Limbach PA. Selective detection of peptide-oligonucleotide heteroconjugates utilizing capillary HPLC-ICPMS. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2012; 23:1053-1061. [PMID: 22451333 PMCID: PMC3348256 DOI: 10.1007/s13361-012-0366-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2011] [Revised: 12/06/2011] [Accepted: 02/18/2012] [Indexed: 05/31/2023]
Abstract
A method for the selective detection and quantification of peptide:oligonucleotide heteroconjugates, such as those generated by protein:nucleic acid cross-links, using capillary reversed-phase high performance liquid chromatography (cap-RPHPLC) coupled with inductively coupled plasma mass spectrometry detection (ICPMS) is described. The selective detection of phosphorus as (31)P(+), the only natural isotope, in peptide-oligonucleotide heteroconjugates is enabled by the elemental detection capabilities of the ICPMS. Mobile phase conditions that allow separation of heteroconjugates while maintaining ICPMS compatibility were investigated. We found that trifluoroacetic acid (TFA) mobile phases, used in conventional peptide separations, and hexafluoroisopropanol/triethylamine (HFIP/TEA) mobile phases, used in conventional oligonucleotide separations, both are compatible with ICPMS and enable heteroconjugate separation. The TFA-based separations yielded limits of detection (LOD) of ~40 ppb phosphorus, which is nearly seven times lower than the LOD for HFIP/TEA-based separations. Using the TFA mobile phase, 1-2 pmol of a model heteroconjugate were routinely separated and detected by this optimized capLC-ICPMS method.
Collapse
Affiliation(s)
- Brittany Catron
- University of Cincinnati/Agilent Technologies Metallomics Center of the Americas, Department of Chemistry, University of Cincinnati, Cincinnati, OH 45221-0172, USA
- Rieveschl Laboratories for Mass Spectrometry, Department of Chemistry, University of Cincinnati, P.O. Box 210172, Cincinnati, OH 45221-0172, USA
| | - Joseph A. Caruso
- University of Cincinnati/Agilent Technologies Metallomics Center of the Americas, Department of Chemistry, University of Cincinnati, Cincinnati, OH 45221-0172, USA
| | - Patrick A. Limbach
- Rieveschl Laboratories for Mass Spectrometry, Department of Chemistry, University of Cincinnati, P.O. Box 210172, Cincinnati, OH 45221-0172, USA
| |
Collapse
|
22
|
Improving the precision of quantitative bottom-up proteomics based on stable isotope-labeled proteins. Anal Bioanal Chem 2012; 404:1079-87. [PMID: 22535440 DOI: 10.1007/s00216-012-6007-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2012] [Revised: 03/29/2012] [Accepted: 03/30/2012] [Indexed: 12/31/2022]
Abstract
Stable isotope dilution-based quantitative proteomics with intact labeled proteins as internal standards in combination with a bottom-up approach, i.e., with quantification on the peptide level, is an established method. To explore the technical precision of this approach, calmodulin-like protein 3 was prepared in non-labeled (light) and SILAC-type labeled (heavy) form by cell-free synthesis, mixed, digested with trypsin, and analyzed by UPLC-ESI-MS. In total, 16 light/heavy peptide pair ratios were determined. Pair-wise comparison of ratios of 12 peptides selected according to S/N ratios >50 revealed that the majority exhibited ratios, which were different at a high level of statistical significance (p < 0.001). HPLC-MALDI-MS ratio data confirmed this observation, thus excluding the ionization method as a source of the observed ratio differences. Variation of the digestion time from 0.25 to 4 h showed that the light/heavy ratios of most peptides decrease with time, indicating a kinetic isotope effect leading to preferred cleavage of light calmodulin-like protein 3. The subset of peptides with statistically identical ratios resulted in an average ratio with a RSD of 1.0 %. The light/heavy ratio calculated on the basis of these peptides probably provides the most accurate molar protein ratio.
Collapse
|
23
|
Schwarz G, Beck S, Weller MG, Linscheid MW. MeCAT—new iodoacetamide reagents for metal labeling of proteins and peptides. Anal Bioanal Chem 2011; 401:1203-9. [DOI: 10.1007/s00216-011-5189-7] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2010] [Revised: 06/01/2011] [Accepted: 06/14/2011] [Indexed: 10/18/2022]
|
24
|
Grebe M, Pröfrock D, Kakuschke A, Broekaert JAC, Prange A. Absolute quantification of transferrin in blood samples of harbour seals using HPLC-ICP-MS. Metallomics 2011; 3:176-85. [PMID: 21270996 DOI: 10.1039/c0mt00076k] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Harbour seals (Phoca vitulina) are bio-indicators for the assessment of their habitat and environmental changes. Besides population parameters and trends (survival, age structure, sex ratio), the individual health status represents a further important parameter for this assessment. The health status of seals is a complex and vague term, determined by a wide range of diagnostic parameters. Quantities of important blood proteins such as transferrin (Tf), as well as altered distribution patterns of its glycoforms, are frequently used as biomarkers in clinical diagnosis. Within this context Tf quantities and a varying pattern of its glycoforms are used as indicator for e.g. certain liver diseases, which also represents one of the most frequently observed pathological indication in harbour seals of the North Sea. Currently, most assay based quantification methods for Tf are limited since they often provide only information regarding the total Tf concentration rather than information of its different glycoforms. Due to a lack of suitable seal Tf antibodies also the application of more specific antibody based approaches is not possible. Within this background a new approach for the absolute quantification of the iron-transport protein Tf in the blood of harbour seals using its characteristic iron content and HPLC-ICP-MS detection is described. Method validation was performed using a certified human serum reference material (ERM-DA470K/IFCC). A Tf concentration of 2.33 ± 0.03 g L(-1) (sum of all quantified glycoforms) has been calculated, which is in good agreement with the certified total Tf concentration of 2.35 ± 0.08 g L(-1), confirming the accuracy of the proposed analytical method. Finally, different seal samples were analysed to demonstrate the suitability of the procedure for the quantification of Tf in real samples as well as to observe modified glycoform patterns. Compared to our previous studies for the first time it was possible to quantify the serum Tf baseline reference range for male (1.42-2.35 g L(-1)) and female German North Sea seals (1.93-2.74 g L(-1)) as well as a CDT level of 0.00-0.10 g L(-1), respectively, which provides valuable further diagnostic information regarding the health status of these specific marine mammals. Compared to assay based quantification approaches the proposed technique indicates great potential to obtain comparable and traceable absolute quantitative results, which are in particular important for long term investigations. This absolute quantification is based on an accurate, traceable element standard, while assay based approaches often show variations depending on the kit quality or changing activities of the used antibodies.
Collapse
Affiliation(s)
- Mechthild Grebe
- Helmholtz-Zentrum Geesthacht, Institute for Coastal Research, Marine Bioanalytical Chemistry, Max-Planck-Str. 1, 21502 Geesthacht, Germany.
| | | | | | | | | |
Collapse
|
25
|
Hahn B, Böhm M, Raia V, Zinn N, Möller P, Klingmüller U, Lehmann WD. One-source peptide/phosphopeptide standards for accurate phosphorylation degree determination. Proteomics 2011; 11:490-4. [DOI: 10.1002/pmic.201000569] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2010] [Revised: 11/04/2010] [Accepted: 11/08/2010] [Indexed: 11/08/2022]
|
26
|
Eyrich B, Sickmann A, Zahedi RP. Catch me if you can: mass spectrometry-based phosphoproteomics and quantification strategies. Proteomics 2011; 11:554-70. [PMID: 21226000 DOI: 10.1002/pmic.201000489] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2010] [Revised: 09/13/2010] [Accepted: 09/21/2010] [Indexed: 01/16/2023]
Abstract
Phosphorylation of proteins is one of the most prominent PTMs and for instance a key regulator of signal transduction. In order to improve our understanding of cellular phosphorylation events, considerable effort has been devoted to improving the analysis of phosphorylation by MS-based proteomics. Different enrichment strategies for phosphorylated peptides/proteins, such as immunoaffinity chromatography (IMAC) or titanium dioxide, have been established and constantly optimized for subsequent MS analysis. Concurrently, specific MS techniques were developed for more confident identification and phosphorylation site localization. In addition, more attention is paid to the LC-MS instrumentation to avoid premature loss of phosphorylated peptides within the analytical system. Despite major advances in all of these fields, the analysis of phosphopeptides still remains far from being routine in proteomics. However, to reveal cellular regulation by phosphorylation events, not only qualitative information about the phosphorylation status of proteins but also, in particular, quantitative information about distinct changes in phosphorylation patterns upon specific stimulation is mandatory. Thus, yielded insights are of outstanding importance for the emerging field of systems biology. In this review, we will give an insight into the historical development of phosphoproteome analysis and discuss its recent progress particularly regarding phosphopeptide quantification and assessment of phosphorylation stoichiometry.
Collapse
Affiliation(s)
- Beate Eyrich
- Leibniz-Institut für Analytische Wissenschaften-ISAS-eV, Dortmund, Germany
| | | | | |
Collapse
|
27
|
Solà-Vázquez A, Costa-Fernández JM, Pereiro R, Sanz-Medel A. Plasma-based mass spectrometry for simultaneous acquisition of elemental and molecular information. Analyst 2011; 136:246-56. [DOI: 10.1039/c0an00581a] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
28
|
Pröfrock D. Progress and possible applications of miniaturised separation techniques and elemental mass spectrometry for quantitative, heteroatom-tagged proteomics. Anal Bioanal Chem 2010; 398:2383-401. [PMID: 20582698 DOI: 10.1007/s00216-010-3901-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2010] [Revised: 06/03/2010] [Accepted: 06/06/2010] [Indexed: 12/23/2022]
Abstract
The application of miniaturised separation techniques such as capillary LC, nano LC or capillary electrophoresis offers a number of advantages in terms of analytical performance, solvent consumption and the ability to analyse very small sample amounts. These features make them attractive for various bioanalytical tasks, in particular those related to the analysis of proteins and peptides. The skillful combination of such techniques with inductively coupled plasma mass spectrometry (ICP-MS) has recently permitted the design of combined analytical approaches utilising either elemental or molecule-specific detection techniques such as electrospray ionisation (ESI) or matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry in a highly complementary manner for, as an example, proteomics-orientated research (heteroatom-tagged proteomics). Such hybrid approaches are, in particular, providing promising new options for the fast screening of complex samples for specific metal-containing or--more generally speaking--heteroatom-containing biomolecules, as well as the accurate absolute quantification of biomolecules, which is still an unsolved problem in bioanalysis. Here, progress in as well as the potential and the special requirements of hyphenating miniaturised separation techniques with ICP-MS are reviewed and critically discussed. In addition, selected applications are highlighted to indicate current and possible future trends within this emerging area of research.
Collapse
Affiliation(s)
- Daniel Pröfrock
- GKSS Forschungszentrum GmbH, Department Marine Bioanalytical Chemistry, Institute for Coastal Research, Max-Planck Str. 1, 21502 Geesthacht, Germany.
| |
Collapse
|
29
|
Zinn N, Winter D, Lehmann WD. Recombinant Isotope Labeled and Selenium Quantified Proteins for Absolute Protein Quantification. Anal Chem 2010; 82:2334-40. [DOI: 10.1021/ac9025412] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Nico Zinn
- Molecular Structure Analysis, German Cancer Research Center, Im Neuenheimer Feld 280, Heidelberg, Germany
| | - Dominic Winter
- Molecular Structure Analysis, German Cancer Research Center, Im Neuenheimer Feld 280, Heidelberg, Germany
| | - Wolf D. Lehmann
- Molecular Structure Analysis, German Cancer Research Center, Im Neuenheimer Feld 280, Heidelberg, Germany
| |
Collapse
|