1
|
Wydall S, Zolger D, Owolabi A, Nzekwu B, Onwochei D, Desai N. Comparison of different delivery modalities of epidural analgesia and intravenous analgesia in labour: a systematic review and network meta-analysis. Can J Anaesth 2023; 70:406-442. [PMID: 36720838 DOI: 10.1007/s12630-022-02389-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2022] [Revised: 09/15/2022] [Accepted: 09/16/2022] [Indexed: 02/02/2023] Open
Abstract
PURPOSE In labour, neuraxial analgesia is the standard in the provision of pain relief. However, the optimal mode of delivering epidural solution has not been determined, and some parturients may need an alternative to epidural analgesia. We sought to conduct a systematic review and network meta-analysis to compare continuous epidural infusion (CEI), programmed intermittent epidural bolus (PIEB), computer-integrated CEI, computer-integrated PIEB, patient-controlled epidural bolus (PCEA), fentanyl patient-controlled analgesia (PCA), and remifentanil PCA, either alone or in combination. METHODS We searched CENTRAL, CINAHL, Ovid Embase, Ovid Medline, and Web of Science for randomized controlled trials that included nulliparous and/or multiparous parturients in spontaneous or induced labour. The maintenance epidural solution had to include a low concentration local anesthetic and an opioid. Specific subgroups in the obstetric population such as preeclampsia were excluded. Network meta-analysis was performed with a frequentist method, and continuous and dichotomous outcomes are presented as mean differences and odds ratios, respectively, with 95% confidence intervals. RESULTS Overall, 73 trials were included. For the first coprimary outcome, the need for rescue analgesia, CEI was inferior to PIEB and PIEB + PCEA was superior to PCEA alone, with a low certainty of evidence given the presence of serious limitations and imprecision. The second coprimary outcome, the maternal satisfaction, was improved by PIEB + PCEA compared with CEI + PCEA and PCEA alone, with a low quality of evidence in view of the presence of serious limitations and imprecision. Fentanyl PCA increased the requirement for rescue analgesia and decreased maternal satisfaction relative to many methods of delivering epidural solution. In terms of secondary outcomes, PIEB increased analgesic efficacy compared with CEI, and PCEA reduced local anesthetic consumption at the expense of inferior analgesia relative to CEI and PIEB. PIEB + PCEA was superior to CEI + PCEA in regard to the pain score at 2 h and 4 h, consumption of local anesthetic, incidence of lower lower limb motor blockade and the rate of spontaneous vaginal delivery. Fentanyl and remifentanil PCA did not provide the same level of analgesia as all epidural methods, resulted in increasing analgesic ineffectiveness with time spent in labour, and predisposed to a higher incidence of side effects such as nausea and/or vomiting and sedation. Remifentanil PCA was superior to fentanyl PCA for analgesia at an early time point, and it increased the incidence of oxygen desaturation relative to other strategies of delivering epidural solution. CONCLUSIONS Opioid PCA did not provide the same level of analgesia as epidural methods with a higher incidence of side effects. We interpret the findings of our systematic review and network meta-analysis as suggesting PIEB + PCEA to be the optimal delivery mode of epidural solution. Nevertheless, the potential differing importance of the various maternal, fetal, and neonatal outcomes in determining which is optimal has not, to our knowledge, been elucidated yet. STUDY REGISTRATION PROSPERO (CRD42021254978); registered 27 May 2021.
Collapse
Affiliation(s)
- Simon Wydall
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, St Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, UK.
| | - Danaja Zolger
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - Adetokunbo Owolabi
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - Bernadette Nzekwu
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - Desire Onwochei
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, UK
- King's College London, London, UK
| | - Neel Desai
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, UK
- King's College London, London, UK
| |
Collapse
|
2
|
Zhang Y, Qin QR, Hui LT. Motor blocks and operative deliveries with ropivacaine and fentanyl for labor epidural analgesia: A meta-analysis. J Obstet Gynaecol Res 2018; 44:2156-2165. [PMID: 30084116 DOI: 10.1111/jog.13772] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Accepted: 07/04/2018] [Indexed: 11/28/2022]
Affiliation(s)
- Yang Zhang
- 2nd Inpatient Department; Binzhou People's Hospital; Binzhou China
| | - Qing-Rong Qin
- School of Nursing, Binzhou Polytechnic College; Binzhou China
| | - Liang-Tu Hui
- 2nd Inpatient Department; Binzhou People's Hospital; Binzhou China
| |
Collapse
|
3
|
Abstract
Abstract
The American Society of Anesthesiologists Committee on Standards and Practice Parameters and the Task Force on Obstetric Anesthesia and the Society for Obstetric Anesthesia and Perinatology present an updated report of the Practice Guidelines for Obstetric Anesthesia.
Supplemental Digital Content is available in the text.
Collapse
|
4
|
Guo S, Li B, Gao C, Tian Y. Epidural Analgesia With Bupivacaine and Fentanyl Versus Ropivacaine and Fentanyl for Pain Relief in Labor: A Meta-Analysis. Medicine (Baltimore) 2015; 94:e880. [PMID: 26061307 PMCID: PMC4616487 DOI: 10.1097/md.0000000000000880] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The aim of this study was to compare the efficacy and safety of the combinational use of bupivacaine and fentanyl versus ropivacaine and fentanyl in epidural analgesia for labor. Multiple electronic databases were searched by using appropriate MeSH terms, and keywords for original research papers published before October 2014. Meta-analyses were based on mean differences between the groups as well as odds ratios. Statistical heterogeneity was tested by I² index. Fifteen randomized controlled trials, recruiting 2097 parturient mothers overall, were selected for the meta-analyses. Concentrations of the preparations used (weight/volume; mean and standard deviations) were bupivacaine 0.1023% ± 0.0375%, ropivacaine 0.1095% ± 0.042%, and fentanyl 0.00021% ± 0.000089%. There were no statistically significant differences between both the combinations in the mean change in Visual Analog Score for pain during labor, incidence of instrumental or cesarean delivery, neonate Apgar score of <7, maternal satisfaction, duration of either first or second stage of labor, oxytocin use for induction, onset of analgesia, and duration of analgesia. Women who received ropivacaine and fentanyl had significantly lower incidence of motor blocks (odds ratio [95% CI] = 0.38 [0.30, 0.48] P < 0.00001, fixed effect and 0.38 [0.27, 0.54] P < 0.0001, random effects I² 30%) when compared with women who received bupivacaine and fentanyl. Incidence of side effects was similar for both the combinations. Analgesia with ropivacaine in combination with fentanyl at 0.1%:0.0002% ratio for labor pain relief is associated with lower incidence of motor blocks in comparison with analgesia with bupivacaine and fentanyl at similar ratio (0.1%: 0.0002%).
Collapse
Affiliation(s)
- Shanbin Guo
- From the Department of Pharmacy, Shengjing Hospital of China Medical University, Shenyang (SG); Department of Anesthesiology, Jinan General Hospital, PLA Jinan Military Area Command, Jinan (BL, CG); and Department of Anesthesiology, Shengjing Hospital of China Medical University, Shenyang, China (YT)
| | | | | | | |
Collapse
|
5
|
Li Y, Hu C, Fan Y, Wang H, Xu H. Epidural analgesia with amide local anesthetics, bupivacaine, and ropivacaine in combination with fentanyl for labor pain relief: a meta-analysis. Med Sci Monit 2015; 21:921-8. [PMID: 25816849 PMCID: PMC4395021 DOI: 10.12659/msm.892276] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Background The study compares the effectiveness of bupivacaine and fentanyl (BUPI-FEN) and ropivacaine and fentanyl (ROPI-EFN) in epidural analgesia for labor pain through a meta-analysis of relevant randomized clinical trials. Material/Methods Multiple electronic databases were searched using appropriate MeSH terms and keywords for original English language research papers published between 1990 and March 2014. Meta-analyses results were based on the mean differences between the groups as well as odds ratios where appropriate. Statistical heterogeneity amongst the included studies was tested by I2 index. Results Nine studies that met the inclusion criteria were selected for analysis which consisted of 556 parturient patients. The duration of the second stage of labor was significantly shorter in the BUPI-FEN group by a mean of −6.87 (−10.98, −2.77; P<0.002). On the other hand, the ROPI-FEN group had a significantly lower incidence of motor blockade by a mean of 0.31 (0.18, 0.51; P<0.00001). A positive relationship between the amide local anesthetic concentration and the number of women having motor blockade was observed, but a negative relationship between fentanyl concentration and the number of women experiencing a motor block. Moreover, a positive correlation was found between the concentration of ropivacaine and the incidence of instrumental delivery and between the concentration of bupivacaine and the incidence of cesarean delivery. Conclusions In combination with fentanyl, bupivacaine and ropivacaine exhibit comparable efficacy and safety. However, BUP-FEN analgesia led to a shortened second-stage labor and ROPI-FEN resulted in a significantly lower incidence of motor block.
Collapse
Affiliation(s)
- Yiyang Li
- Department of Gynecology, First Hospital of Jilin University, Changchun, Jilin, China (mainland)
| | - Cong Hu
- Center of Reproductive Medicine, First Hospital of Jilin University, Changchun, Jilin, China (mainland)
| | - Yanyan Fan
- Department of Gynecology, First Hospital of Jilin University, Changchun, Jilin, China (mainland)
| | - Huixia Wang
- Department of Anesthesiology, Jinan General Hospital, PLA Jinan Military Area Command, Jinan, Shandong, China (mainland)
| | - Hongmei Xu
- Department of Obstetrics, First Hospital of Jilin University, Changchun, Jilin, China (mainland)
| |
Collapse
|
6
|
Haydon ML, Larson D, Reed E, Shrivastava VK, Preslicka CW, Nageotte MP. Obstetric outcomes and maternal satisfaction in nulliparous women using patient-controlled epidural analgesia. Am J Obstet Gynecol 2011; 205:271.e1-6. [PMID: 22071061 DOI: 10.1016/j.ajog.2011.06.041] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2011] [Revised: 05/02/2011] [Accepted: 06/09/2011] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The purpose of this study was to compare obstetric outcomes and maternal satisfaction in nulliparous women in spontaneous labor who used patient-controlled epidural analgesia (PCEA) vs continuous epidural infusion (CEI). STUDY DESIGN We conducted a double-masked trial of 270 nulliparous women who were assigned randomly to 3 groups (with a concentration 0.1% bupivacaine and 2 μg/mL fentanyl): group I, CEI-only (10 mL/h); group II, CEI + PCEA (CEI 10 mL/h plus PCEA 10 mL, at 20 minutes); group III, PCEA-only (10 mL, at 20 minutes). A PCEA bolus button was given to each subject. The primary outcome was the dosage of local anesthetic that was used. RESULTS The total milligrams of bupivacaine that were used was less in the PCEA-only group compared with CEI: group I. 74.8 ± 36 mg; group II, 97.3 ± 53 mg; group III, 52.4 ± 42 mg (P < .001). Pain with pushing, however, was worse in the PCEA-only group. Median satisfaction scores were similar (scale, 0 [best] to 100 [worst]: group I, 0; group II, 0; group III, 0 (P = .23). CONCLUSION PCEA results in less anesthetic used, and maternal satisfaction remains high without a continuous infusion. Pain with pushing, however, was worse with the PCEA alone.
Collapse
|
7
|
Van de Velde M. Modern neuraxial labor analgesia: options for initiation, maintenance and drug selection. ACTA ACUST UNITED AC 2010; 56:546-61. [PMID: 20112546 DOI: 10.1016/s0034-9356(09)70457-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
In the present review we outline the state-of-the-art of neuraxial analgesia. As neuraxial analgesia remains the gold standar of analgesia during labor, we review the most recent literature on this topic. The neuraxial analgesia techniques, types of administration, drugs, adjuvants, and adverse effects are investigated from the references. Most authors would agree that central neuraxial analgesia is the best form to manage labor pain. When neuraxial analgesia is administered to the parturient in labor, different management choices must be made by the anesthetist: how will we initiate analgesia, how will analgesia be maintained, which local anesthetic will we use for neuraxial analgesia and which adjuvant drugs will we combine? The present manuscript tries to review the literature to answer these questions.
Collapse
Affiliation(s)
- M Van de Velde
- Department of Anesthesiology, University Hospitals Gasthuisberg, Katholieke Universiteit Leuven, Leuven, Belgium.
| |
Collapse
|
8
|
Affiliation(s)
- Richard M Smiley
- Columbia University Medical Center, Department of Anesthesiology, New York, New York 10032, USA.
| | | |
Collapse
|
9
|
Abstract
New low-dose, local anesthetic-opioid combinations, combined spinal epidural analgesia, and new anesthetic drugs, such as ropivacaine and levobupivacaine, have modified the anesthetic practice in obstetric labor analgesia. These new analgesic techniques have less or no neonatal effects when compared with traditional epidural labor analgesia. They also have less effect on mode of delivery, which may in turn affect neonatal outcome. The use of very diluted or low concentrations of local anesthetic solutions may reduce their placental passage and thus the possible subtle neonatal effects. Small doses of epidural or spinal opioids alone or combined with low doses of local anesthetics does not affect the well-being of the neonate at birth. When considering the neonatal outcome, combined spinal epidural analgesia is as well tolerated as low-dose epidural analgesia. Transient fetal heart rate changes have been described immediately after the administration of intrathecal or epidural opioids. Maternal hypotension may also occur at the onset of epidural analgesia. Whether the occurrence of transient fetal heart rate changes or maternal hypotension immediately after the epidural block may influence the neonatal outcome at birth needs verification.
Collapse
Affiliation(s)
- Giorgio Capogna
- Department of Anesthesia, Città di Roma Hospital, Rome, Italy.
| | | |
Collapse
|
10
|
Stratmann G, Gambling DR, Moeller-Bertram T, Stackpole J, Pue AF, Berkowitz J. A randomized comparison of a five-minute versus fifteen-minute lockout interval for PCEA during labor. Int J Obstet Anesth 2005; 14:200-7. [PMID: 15936187 DOI: 10.1016/j.ijoa.2004.12.008] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2004] [Revised: 12/05/2004] [Accepted: 12/10/2004] [Indexed: 10/25/2022]
Abstract
BACKGROUND The best combination of bolus size and lockout interval for patient-controlled epidural analgesia (PCEA) is not known. This study compared a 5-min with a 15-min lockout interval. METHODS Parturients were randomly assigned to receive PCEA with either a 5-min or a 15-min interval. All had a 15-mL loading dose, continuous background infusion 6 mL/h of 0.125% bupivacaine plus fentanyl 2 mug/mL, PCEA bolus volume 5 mL, maximum hourly dose 26 mL. Visual analogue scores for pain, nausea and pruritus, sensory levels to ice, sacral analgesia, motor power, blood pressure and fetal heart rate were assessed pre-epidural and regularly thereafter until delivery. The numbers of boluses and attempts and patient satisfaction were recorded. RESULTS 29 patients were assigned to the 5-min group and 31 to the 15-min group, but the 15-min group contained twice as many nulliparous women. Side-effect and complication rates did not differ between groups. VAS pain scores were reduced from a median of 79 in the 15-min group and 82 in the 5-min group to a median of zero 30 min after epidural insertion. Bolus/attempt ratio was 0.88 in the 5-min vs. 0.70 in the 15-min group. The numbers of requests for physician intervention were similar. No differences in pain scores, side-effects, drug use or patient satisfaction were demonstrated. CONCLUSION The 5-min lockout interval appears the more efficient and has been used safely in our practice for 15,000 parturients, although a larger study is required to confirm the relative efficacy, efficiency and safety of this regimen.
Collapse
Affiliation(s)
- G Stratmann
- Department of Anesthesia and Perioperative Care, University of California San Francisco Moffitt Hospital, San Francisco, CA 94143, USA.
| | | | | | | | | | | |
Collapse
|
11
|
|
12
|
Bernard JM, Le Roux D, Frouin J. Ropivacaine and Fentanyl Concentrations in Patient-Controlled Epidural Analgesia During Labor: A Volume-Range Study. Anesth Analg 2003; 97:1800-1807. [PMID: 14633563 DOI: 10.1213/01.ane.0000090149.42478.b5] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
UNLABELLED We enrolled nulliparous women in induced labor in a randomized study to determine whether increasing the concentration of the solution used in a patient-controlled epidural analgesia (PCEA) device was required as labor progressed. Patients were assigned to 6 groups (n = 25 in each group), receiving ropivacaine/fentanyl in concentrations of either 0.1%/0.5 microg/mL or 0.2%/1 microg/mL via a PCEA pump. Three groups received boluses of 12, 16, or 20 mL dilute solution in early labor (uterine contractions every 3 min and 4-cm cervical dilation) then 6, 8, and 10 mL concentrated solution in late labor. Three other groups received boluses of 12, 16, or 20 mL dilute solution during both periods. The lockout interval was 25 min. The primary outcome was time until the first request for staff-administered analgesia supplement. Hourly assessments included pain scores on a visual analog scale (VAS) graded from 0 to 10, satisfaction scores, arterial blood pressure, motor block intensity, and the upper sensory level of epidural anesthesia. Patients, midwives, and the observer were unaware of study solutions and PCEA settings. The maximum pain score was defined as the highest score experienced by each patient during each period. Duration of analgesia was defined as the time from the start of each period to the first injection of rescue analgesia and was compared using a survival analysis. There were no differences among the groups with regard to demographic and obstetric variables, arterial blood pressure, motor block intensity, upper sensory level, or satisfaction scores. At least 75% of the women rated their satisfaction as either good or excellent during each period. During late labor, the maximum pain score was lower in the group receiving 20 mL dilute solution compared with the group receiving 6 mL concentrated solution. Maximum pain score was not significantly different between 20 mL dilute solution and 10 mL concentrated solution (difference between VAS values = -0.4; 95% confidence limits, -1.599 and 0.799; P = 0.5055). During late labor, the duration of analgesia was longer in groups receiving 20 mL dilute solution (99 +/- 4 min) (mean +/- SD) than in those receiving 12 mL (77 +/- 30 min) and 16 mL (80 +/- 23 min). Duration of analgesia did not differ between groups receiving 20 mL and 10 mL (92 +/- 23 min) or between groups receiving 12 mL and 6 mL (78 +/- 30 min) of each respective solution. Duration of analgesia was longer in the groups receiving 8 mL concentrated solution (94 +/- 16 min) than in those receiving 16 mL dilute solution. We concluded that 0.1%/0.5 microg/mL ropivacaine/fentanyl was effective throughout labor when 20 mL was injected with each PCEA demand. With 16 mg ropivacaine and 8 microg fentanyl, the duration of analgesia was prolonged by doubling the concentration when labor became active. When 12 mg ropivacaine and 6 microg fentanyl were injected at each demand, analgesia was less satisfactory and doubling the concentration was not clinically effective. These results suggest that the effectiveness of PCEA is dependent on drug mass rather than the volume or concentration administered with each successful pump demand. IMPLICATIONS There is no clinical reason for increasing the concentration of the patient-controlled epidural analgesia (PCEA) solution when labor becomes active provided that an effective dose is already being administered with each demand. The quality of PCEA depends on the drug mass given with each demand rather than the concentration of the pump solution.
Collapse
Affiliation(s)
- Jean-Marc Bernard
- From the Département d'Anesthésie-Réanimation, Polyclinique Jean-Villar, Bruges-Bordeaux, France
| | | | | |
Collapse
|
13
|
Ledin Eriksson S, Gentele C, Olofsson CH. PCEA compared to continuous epidural infusion in an ultra-low-dose regimen for labor pain relief: a randomized study. Acta Anaesthesiol Scand 2003; 47:1085-90. [PMID: 12969100 DOI: 10.1034/j.1399-6576.2003.00207.x] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
BACKGROUND Patient-controlled epidural analgesia, PCEA, has been introduced in obstetric analgesia during the past decade. Many studies have shown that the consumption of analgesic is reduced when the parturient requests her own doses. This study investigates whether this is also true when using an ultra-low-dose regimen. METHODS Eighty parturients were prospectively randomized to have either continuous epidural infusion (CEI) with ropivacaine 1 mg ml-1 and sufentanil 0.5 micro g ml-1, 6 ml h-1, or patient-controlled epidural analgesia (PCEA) with 4 ml demand doses with 20 min' lockout. The epidural start dose was the same for the two groups, 8 ml of the study solution. Rescue bolus doses were given when needed and the continuous infusion could be increased, which gave the two groups the same maximum possible dose. The consumption of local ropivacaine in combination with sufentanil during labor was registered. Hourly assessments made throughout labor included pain intensity documented with visual analog score, VAS, the patient's opinion on epidural efficacy, motor block, pruritus and need for nitrous oxide. RESULTS The PCEA group consumed 33% less of the study solution than the CEI group. Mean total consumption was 35 ml (SD 18.0) and 52 ml (SD 19.6), respectively. Mean hourly consumption was 5.2 ml h-1 (SD 2.54) in the PCEA group and 6.9 ml h-1 (SD 1.31) in the CEI group. There were no significant differences between the two groups in pain relief, epidural efficacy, side-effects or obstetric outcome. CONCLUSION PCEA reduces doses compared to continuous infusion even when ultra-low-dose local anesthetic with opioid is used. The PCEA technique provides individual titration of doses to an acceptable degree of pain relief.
Collapse
Affiliation(s)
- S Ledin Eriksson
- Department of Anaesthesiology and Intensive Care, Gävle-Sandviken County Hospital, Gävle, Sweden.
| | | | | |
Collapse
|
14
|
Paech M. Patient-controlled epidural analgesia for labor and delivery: a novelty or a practical method? ACTA ACUST UNITED AC 2003. [DOI: 10.1053/j.trap.2003.10.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
15
|
|
16
|
Boselli E, Debon R, Duflo F, Bryssine B, Allaouchiche B, Chassard D. Ropivacaine 0.15% plus sufentanil 0.5 microg/mL and ropivacaine 0.10% plus sufentanil 0.5 microg/mL are equivalent for patient-controlled epidural analgesia during labor. Anesth Analg 2003; 96:1173-1177. [PMID: 12651679 DOI: 10.1213/01.ane.0000054168.36798.4a] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
UNLABELLED We compared the administration of 0.15% ropivacaine plus 0.5 microg/mL of sufentanil with that of 0.10% ropivacaine plus 0.5 microg/mL of sufentanil for labor analgesia with patient-controlled epidural analgesia (PCEA) to determine whether a decreased concentration of ropivacaine could produce equally effective analgesia. One-hundred-thirty healthy pregnant women at term were randomized in a double-blinded fashion. The PCEA settings were as follows: 12-mL initial bolus, 5-mL bolus dose, 5-min lockout interval, and 10 mL/h basal infusion. Patient demographics and labor characteristics were comparable in both groups. No differences were observed for pain scores, maternal satisfaction, volume of anesthetic solution administered, number of boluses requested and delivered, need for supplemental boluses, mode of delivery, motor block, side effects, or Apgar scores. Patients in the 0.10% ropivacaine group used significantly less drug than those in the 0.15% group (mean, 57 mg; 95% confidence interval, 50.5-63.5 mg; versus mean, 88.0 mg; 95% confidence interval, 74.4-93.3 mg, respectively; P < 0.0001). Ropivacaine 0.10% plus 0.5 microg/mL of sufentanil administered via PCEA for labor analgesia is equally effective as ropivacaine 0.15% plus 0.5 microg/mL of sufentanil, with a 30% local anesthetic-sparing effect and a 40% reduction in cost. However, this reduction in local anesthetic is not associated with a decrease in the incidence of motor block, side effects, or instrumental deliveries. IMPLICATIONS Ropivacaine 0.10% plus 0.5 microg/mL of sufentanil given via patient-controlled epidural anesthesia for labor analgesia is equally as effective as ropivacaine 0.15% plus 0.5 microg/mL of sufentanil, with a 30% local anesthetic-sparing effect and a 40% reduction in cost. This reduction in ropivacaine concentration is not associated with a decrease in the incidence of motor block, side effects, or instrumental deliveries.
Collapse
|
17
|
Abstract
In maternity units in which central neuraxial techniques are frequently used, newer methods of epidural drug delivery (continuous infusion, patient-controlled) are well established and combined spinal-epidural analgesia is commonly used. Continuous spinal analgesia has reemerged as a useful approach after accidental dural puncture. Lumbar sympathetic block has been revisited and the safety of paracervical nerve block improved. The analgesic properties of systemic opioid in labor are poor, but PCIA at least has psychological benefits and allows rapid drug titration. PCIA is again under investigation because of the potent antinociceptive effects of the short-acting mu-opioid agonist, remifentanil. The premixing of nitrous oxide and a subanesthetic concentration of volatile anesthetic for patient-controlled administration has been tested under control of midwifery staff and without direct medical supervision.
Collapse
Affiliation(s)
- Michael Paech
- Department of Medicine and Pharmacology, University of Western Australia, Department of Anaesthesia and Pain Medicine, King Edward Memorial Hospital for Women and Royal Perth Hospitals, Western Australia, Australia.
| |
Collapse
|
18
|
Abstract
PURPOSE OF THE REVIEW There has recently been a growing interest in developing and modulating the techniques of neuraxial analgesia to meet the changing individual needs of parturients for pain relief during the course of labour and delivery. RECENT FINDINGS Neuraxial analgesia is now very safe. Modern low-dose spinal-epidural regimens provide efficacious analgesia, stable maternal haemodynamics and few tolerable side effects. Complications are possible, however, due to the invasive nature of the technique, patient characteristics or medical malpractice. SUMMARY Labour epidural analgesia still remains the 'gold standard' of obstetric pain management, although spinal analgesia with the single-injection technique is an attractive option due to its simplicity, reliability and efficacy. Up till now, there has been no single new drug to overcome the superiority of neuraxial analgesia in obstetrics.
Collapse
Affiliation(s)
- Pirjo O Ranta
- Department of Anaesthesiology and Intensive Care Medicine, Oulu University, Oulu, Finland.
| |
Collapse
|
19
|
Pirbudak L, Tuncer S, Koçoğlu H, Göksu S, Çelik Ç. Fentanyl added to bupivacaine 0.05% or ropivacaine 0.05% in patient-controlled epidural analgesia in labour. Eur J Anaesthesiol 2002. [DOI: 10.1097/00003643-200204000-00004] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
20
|
Hofmann-Kiefer K, Saran K, Brederode A, Bernasconi H, Zwissler B, Schwender D. Ropivacaine 2 mg/mL vs. bupivacaine 1.25 mg/mL with sufentanil using patient-controlled epidural analgesia in labour. Acta Anaesthesiol Scand 2002; 46:316-21. [PMID: 11939924 DOI: 10.1034/j.1399-6576.2002.t01-1-460315.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
BACKGROUND In recent studies, minimum local analgesic concentrations have been defined as 0.93 mg/mL for bupivacaine and 1.56 mg/mL for ropivacaine for epidural analgesia for the first stage of labour, resulting in an analgesic potency ratio of 1 : 0.6. In the current study we compared ropivacaine and bupivacaine in a PCEA system (combined with sufentanil) taking this potency ratio into account but administering drug doses providing sufficient analgesia for all stages of labour. METHODS In a prospective, double-blinded study 114 parturients were randomised to receive either ropivacaine 2 mg/mL with sufentanil 0.75 microg/mL or bupivacaine 1.25 mg/with sufentanil 0.75 microg/mL. After epidural catheter placement, PCEA was available with boluses of 4 mL, a lock-out time of 20 min and no basal infusion rate. We evaluated pain intensity during contractions, sensory and motor function, duration of labour, mode of delivery and neonatal outcome. Consumption of local anaesthetic and opioid drugs and PCEA system variables were recorded. RESULTS Mean total consumption as well as mean hourly drug consumption was significantly increased in the ropivacaine-sufentanil group. No differences in analgesic quality, sensory or motor blocking potencies or neonatal outcome variables between groups were detected. Frequency of instrumental deliveries was significantly increased in the ropivacaine-sufentanil group. CONCLUSIONS The results support the findings of previously published studies postulating ropivacaine to be 40-50% less potent for labour epidural analgesia compared to bupivacaine. However, we observed an increased frequency of instrumental deliveries with ropivacaine. To evaluate the clinical relevance of these findings, further investigations are warranted.
Collapse
Affiliation(s)
- K Hofmann-Kiefer
- Klinik für Anäesthesiologie der Ludwig-Maximilians-Universität München, Klinikum Innenstadt, Munich, Germany
| | | | | | | | | | | |
Collapse
|
21
|
Abstract
Epidural and spinal analgesia for pain relief in labour are now commonplace. Adverse effects such as hypotension and toxicity to anaesthetic agents are well described and easily managed. The effects on obstetric outcome, however, have been unclear to both obstetricians and anaesthetists, but are important due to the large number of pregnancies involved. Efforts to define implications for mother and child have been frustrated by a relative lack of evidence derived from good quality, large randomized trials. Ethical and methodological difficulties together with an abundance of confounding factors have conspired to cause considerable difficulties for researchers in this area. Nevertheless, recent evidence has significantly advanced knowledge in the field and has implications for future practice.
Collapse
Affiliation(s)
- A Thallon
- Maternal and Fetal Health Research Unit, 10th Floor North Wing, St Thomas' Hospital, Lambeth Palace Rd, London, SE1 7EH UK
| | | |
Collapse
|