1
|
Huang L, Aurisano N, Fantke P, Dissanayake A, Edirisinghe LGLM, Jolliet O. Near-field exposures and human health impacts for organic chemicals in interior paints: A high-throughput screening. JOURNAL OF HAZARDOUS MATERIALS 2024; 465:133145. [PMID: 38154180 DOI: 10.1016/j.jhazmat.2023.133145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/26/2023] [Accepted: 11/28/2023] [Indexed: 12/30/2023]
Abstract
Interior paints contain organic chemicals that might be harmful to painters and building residents. This study aims to develop a high-throughput approach to screen near-field human exposures and health impacts related to organic chemicals in interior paints. We developed mass balance models for both water- and solvent-based paints, predicting emissions during wet and dry phases. We then screened exposures and risks, focusing on Sri Lanka where residential houses are frequently repainted. These models accurately predict paint drying time and indoor air concentrations of organic chemicals. Exposures of both painter and household resident were estimated for 65 organic chemicals in water-based and 26 in solvent-based paints, considering 12 solvents. Chemicals of concerns (CoCs) were identified, and maximum acceptable chemical contents (MACs) were calculated. Water-based paints generally pose lower health risks than solvent-based paints but might contain biocides of high concern. The total human health impact of one painting event on all household adults ranges from 1.5 × 10-3 to 2.1 × 10-2 DALYs for solvent-based paints, and from 4.1 × 10-4 to 9.5 × 10-3 DALYs for water-based paints. The present approach is a promising way to support the formulation of safer paint, and is integrated in the USEtox scientific consensus model for use in life cycle assessment, chemical substitution and risk screening.
Collapse
Affiliation(s)
- Lei Huang
- Department of Environmental Health Sciences, School of Public Health, University of Michigan, Ann Arbor, MI, USA
| | - Nicolò Aurisano
- Quantitative Sustainability Assessment, Department of Environmental and Resource Engineering, Technical University of Denmark, Bygningstorvet 115, 2800 Kgs. Lyngby, Denmark
| | - Peter Fantke
- Quantitative Sustainability Assessment, Department of Environmental and Resource Engineering, Technical University of Denmark, Bygningstorvet 115, 2800 Kgs. Lyngby, Denmark
| | | | | | - Olivier Jolliet
- Department of Environmental Health Sciences, School of Public Health, University of Michigan, Ann Arbor, MI, USA; Quantitative Sustainability Assessment, Department of Environmental and Resource Engineering, Technical University of Denmark, Bygningstorvet 115, 2800 Kgs. Lyngby, Denmark.
| |
Collapse
|
2
|
Haug H, Klein L, Sauerwald T, Poelke B, Beauchamp J, Roloff A. Sampling Volatile Organic Compound Emissions from Consumer Products: A Review. Crit Rev Anal Chem 2022; 54:1895-1916. [PMID: 36306209 DOI: 10.1080/10408347.2022.2136484] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
Abstract
Volatile organic compounds (VOCs) are common constituents of many consumer products. Although many VOCs are generally considered harmless at low concentrations, some compound classes represent substances of concern in relation to human (inhalation) exposure and can elicit adverse health effects, especially when concentrations build up, such as in indoor settings. Determining VOC emissions from consumer products, such as toys, utensils or decorative articles, is of utmost importance to enable the assessment of inhalation exposure under real-world scenarios with respect to consumer safety. Due to the diverse sizes and shapes of such products, as well as their differing uses, a one-size-fits-all approach for measuring VOC emissions is not possible, thus, sampling procedures must be chosen carefully to best suit the sample under investigation. This review outlines the different sampling approaches for characterizing VOC emissions from consumer products, including headspace and emission test chamber methods. The advantages and disadvantages of each sampling technique are discussed in relation to their time and cost efficiency, as well as their suitability to realistically assess VOC inhalation exposures.
Collapse
Affiliation(s)
- Helen Haug
- Department of Sensory Analytics and Technologies, Fraunhofer Institute for Process Engineering and Packaging IVV, Freising, Germany
- Department of Chemistry and Pharmacy, Friedrich-Alexander-Universität Erlangen-Nürnberg, Chair of Aroma and Smell Research, Erlangen, Germany
| | - Luise Klein
- Department of Chemical and Product Safety, German Federal Institute for Risk Assessment (BfR), Berlin, Germany
| | - Tilman Sauerwald
- Department of Sensory Analytics and Technologies, Fraunhofer Institute for Process Engineering and Packaging IVV, Freising, Germany
| | - Birte Poelke
- Department of Chemical and Product Safety, German Federal Institute for Risk Assessment (BfR), Berlin, Germany
| | - Jonathan Beauchamp
- Department of Sensory Analytics and Technologies, Fraunhofer Institute for Process Engineering and Packaging IVV, Freising, Germany
| | - Alexander Roloff
- Department of Chemical and Product Safety, German Federal Institute for Risk Assessment (BfR), Berlin, Germany
| |
Collapse
|
3
|
Halios CH, Landeg-Cox C, Lowther SD, Middleton A, Marczylo T, Dimitroulopoulou S. Chemicals in European residences - Part I: A review of emissions, concentrations and health effects of volatile organic compounds (VOCs). THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 839:156201. [PMID: 35623519 DOI: 10.1016/j.scitotenv.2022.156201] [Citation(s) in RCA: 32] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 05/16/2022] [Accepted: 05/20/2022] [Indexed: 06/15/2023]
Abstract
One of the more important classes of potentially toxic indoor air chemicals are the Volatile Organic Compounds (VOCs). However, due to a limited understanding of the relationships between indoor concentrations of individual VOCs and health outcomes, there are currently no universal health-based guideline values for VOCs within Europe including the UK. In this study, a systematic search was conducted designed to capture evidence on concentrations, emissions from indoor sources, and health effects for VOCs measured in European residences. We identified 65 individual VOCs, and the most commonly measured were aromatic hydrocarbons (14 chemicals), alkane hydrocarbons (9), aldehydes (8), aliphatic hydrocarbons (5), terpenes (6), chlorinated hydrocarbons (4), glycol and glycol ethers (3) and esters (2). The pathway of interest was inhalation and 8 individual aromatic hydrocarbons, 7 alkanes and 6 aldehydes were associated with respiratory health effects. Members of the chlorinated hydrocarbon family were associated with cardiovascular neurological and carcinogenic health effects and some were irritants as were esters and terpenes. Eight individual aromatic hydrocarbons, 7 alkanes and 6 aldehydes identified in European residences were associated with respiratory health effects. Of the 65 individual VOCs, 52 were from sources associated with building and construction materials (e.g. brick, wood products, adhesives and materials for flooring installation etc.), 41 were linked with consumer products (passive, electric and combustible air fresheners, hair sprays, deodorants) and 9 VOCs were associated with space heating, which may reflect the relatively small number of studies discussing emissions from this category of sources. A clear decrease in concentrations of formaldehyde was observed over the last few years, whilst acetone was found to be one of the most abundant but underreported species. A new approach based on the operational indoor air quality surveillance will both reveal trends in known VOCs and identify new compounds.
Collapse
Affiliation(s)
- Christos H Halios
- Air Quality & Public Health Group, Environmental Hazards and Emergencies Department, Radiation, Chemicals and Environmental Hazards, Science Group, UK Health Security Agency, Harwell Science and Innovation Campus, Chilton, UK
| | - Charlotte Landeg-Cox
- Air Quality & Public Health Group, Environmental Hazards and Emergencies Department, Radiation, Chemicals and Environmental Hazards, Science Group, UK Health Security Agency, Harwell Science and Innovation Campus, Chilton, UK
| | - Scott D Lowther
- Air Quality & Public Health Group, Environmental Hazards and Emergencies Department, Radiation, Chemicals and Environmental Hazards, Science Group, UK Health Security Agency, Harwell Science and Innovation Campus, Chilton, UK
| | - Alice Middleton
- Air Quality & Public Health Group, Environmental Hazards and Emergencies Department, Radiation, Chemicals and Environmental Hazards, Science Group, UK Health Security Agency, Harwell Science and Innovation Campus, Chilton, UK
| | - Tim Marczylo
- Toxicology Department, Radiation, Chemicals and Environmental Hazards, Science Group, UK Health Security Agency, Harwell Science and Innovation Campus, Chilton, UK
| | - Sani Dimitroulopoulou
- Air Quality & Public Health Group, Environmental Hazards and Emergencies Department, Radiation, Chemicals and Environmental Hazards, Science Group, UK Health Security Agency, Harwell Science and Innovation Campus, Chilton, UK.
| |
Collapse
|
4
|
Liu Z, Yan Y, Lv T, Huang Z, Liu T, Huang Q, Yang J, Chen Y, Zhao Y, Zhou T. Comprehensive understanding the emission characteristics and kinetics of VOCs from automotive waste paint sludge in a environmental test chamber. JOURNAL OF HAZARDOUS MATERIALS 2022; 429:128387. [PMID: 35236022 DOI: 10.1016/j.jhazmat.2022.128387] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 12/12/2021] [Accepted: 01/26/2022] [Indexed: 06/14/2023]
Affiliation(s)
- Zewei Liu
- The State Key Laboratory of Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China
| | - Yusen Yan
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China; State Environmental Protection Key Laboratory of Hazardous Waste Identification and Risk Control, Chinese Research Academy of Environmental Sciences, Beijing 100012, China
| | - Tianfeng Lv
- China National Environmental Monitoring Centre, Beijing 100012, China
| | - Zechun Huang
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China; State Environmental Protection Key Laboratory of Hazardous Waste Identification and Risk Control, Chinese Research Academy of Environmental Sciences, Beijing 100012, China
| | - Tingting Liu
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China
| | - Qifei Huang
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China; State Environmental Protection Key Laboratory of Hazardous Waste Identification and Risk Control, Chinese Research Academy of Environmental Sciences, Beijing 100012, China.
| | - Jinzhong Yang
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China; State Environmental Protection Key Laboratory of Hazardous Waste Identification and Risk Control, Chinese Research Academy of Environmental Sciences, Beijing 100012, China
| | - Yu Chen
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China; State Environmental Protection Key Laboratory of Hazardous Waste Identification and Risk Control, Chinese Research Academy of Environmental Sciences, Beijing 100012, China
| | - Youcai Zhao
- The State Key Laboratory of Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Tao Zhou
- The State Key Laboratory of Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Tongji University, Shanghai 200092, China.
| |
Collapse
|
5
|
Wang N, Ernle L, Bekö G, Wargocki P, Williams J. Emission Rates of Volatile Organic Compounds from Humans. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:4838-4848. [PMID: 35389619 PMCID: PMC9022422 DOI: 10.1021/acs.est.1c08764] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 03/25/2022] [Accepted: 03/28/2022] [Indexed: 05/30/2023]
Abstract
Human-emitted volatile organic compounds (VOCs) are mainly from breath and the skin. In this study, we continuously measured VOCs in a stainless-steel environmentally controlled climate chamber (22.5 m3, air change rate at 3.2 h-1) occupied by four seated human volunteers using proton transfer reaction time-of-flight mass spectrometry and gas chromatography mass spectrometry. Experiments with human whole body, breath-only, and dermal-only emissions were performed under ozone-free and ozone-present conditions. In addition, the effect of temperature, relative humidity, clothing type, and age was investigated for whole-body emissions. Without ozone, the whole-body total emission rate (ER) was 2180 ± 620 μg h-1 per person (p-1), dominated by exhaled chemicals. The ERs of oxygenated VOCs were positively correlated with the enthalpy of the air. Under ozone-present conditions (∼37 ppb), the whole-body total ER doubled, with the increase mainly driven by VOCs resulting from skin surface lipids/ozone reactions, which increased with relative humidity. Long clothing (more covered skin) was found to reduce the total ERs but enhanced certain chemicals related to the clothing. The ERs of VOCs derived from this study provide a valuable data set of human emissions under various conditions and can be used in models to better predict indoor air quality, especially for highly occupied environments.
Collapse
Affiliation(s)
- Nijing Wang
- Atmospheric
Chemistry Department, Max Planck Institute
for Chemistry, Hahn-Meitner-Weg 1, 55128 Mainz, Germany
| | - Lisa Ernle
- Atmospheric
Chemistry Department, Max Planck Institute
for Chemistry, Hahn-Meitner-Weg 1, 55128 Mainz, Germany
| | - Gabriel Bekö
- International
Centre for Indoor Environment and Energy, Department of Environmental
and Resource Engineering, Technical University
of Denmark, Nils Koppels Alle 402, 2800 Lyngby, Denmark
| | - Pawel Wargocki
- International
Centre for Indoor Environment and Energy, Department of Environmental
and Resource Engineering, Technical University
of Denmark, Nils Koppels Alle 402, 2800 Lyngby, Denmark
| | - Jonathan Williams
- Atmospheric
Chemistry Department, Max Planck Institute
for Chemistry, Hahn-Meitner-Weg 1, 55128 Mainz, Germany
- Climate
& Atmosphere Research Centre, The Cyprus
Institute, 1645 Nicosia, Cyprus
| |
Collapse
|
6
|
Da Ros S, Curran K. Modelling and parameter estimation of diethyl phthalate partitioning behaviour on glass and aluminum surfaces. CHEMOSPHERE 2021; 285:131414. [PMID: 34265716 DOI: 10.1016/j.chemosphere.2021.131414] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Revised: 06/21/2021] [Accepted: 06/30/2021] [Indexed: 06/13/2023]
Abstract
The knowledge of the partitioning behaviour of semi-volatile organic compounds (SVOCs), such as phthalates, between different materials and their surrounding air is of extreme importance for quantifying levels of human exposure to these compounds, which have been associated with adverse health effects. Phthalates' partitioning behaviour also represents a key property for modelling and assessing polymer degradation mechanisms associated with plasticiser loss. However, the characterisation of phthalates partitioning behaviour has been reported only for a limited number of compounds, mainly involving di-2-ethylhexyl phthalate (DEHP), di-isononyl phthalate (DINP) and di-isodecyl phtahalate (DIDP), while the characterisation of diethyl phthalate (DEP) partitioning has been overlooked. As one of the first plasticisers employed in the production of semi-synthetic plastics produced industrially in the late 19th and early 20th century, DEP plays an important role for understanding stability issues associated with historically significant artefacts in museum collections and archives. Here we show that the partitioning behaviour of DEP between borosilicate glass and aluminum surfaces and their surrounding air can be described by an exponential function of temperature, presenting a model to describe this relationship for the first time. Model parameters are estimated using nonlinear regression from experimental measurements acquired using 109 samples which have been equilibrated at different temperatures between 20 and 80 °C in sealed environments. Measured partition coefficients have been predicted accurately by our proposed model. The knowledge of DEP equilibrium distribution between adsorptive surfaces and neighbouring environments will be relevant for developing improved mathematical descriptions of degradation mechanisms related to plasticiser loss.
Collapse
Affiliation(s)
- Simoní Da Ros
- UCL Institute for Sustainable Heritage, University College London, 14 Upper Woburn Place, London, WC1H 0NN, United Kingdom.
| | - Katherine Curran
- UCL Institute for Sustainable Heritage, University College London, 14 Upper Woburn Place, London, WC1H 0NN, United Kingdom.
| |
Collapse
|
7
|
Song MY, Chun H. Species and characteristics of volatile organic compounds emitted from an auto-repair painting workshop. Sci Rep 2021; 11:16586. [PMID: 34400724 PMCID: PMC8368184 DOI: 10.1038/s41598-021-96163-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 08/04/2021] [Indexed: 11/09/2022] Open
Abstract
Volatile organic compounds (VOCs) are secondary pollutant precursors having adverse impacts on the environment and human health. Although VOC emissions, their sources, and impacts have been investigated, the focus has been on large-scale industrial sources or indoor environments; studies on relatively small-scale enterprises (e.g., auto-repair workshops) are lacking. Here, we performed field VOC measurements for an auto-repair painting facility in Korea and analyzed the characteristics of VOCs emitted from the main painting workshop (top coat). The total VOC concentration was 5069-8058 ppb, and 24-35 species were detected. The VOCs were mainly identified as butyl acetate, toluene, ethylbenzene, and xylene compounds. VOC characteristics differed depending on the paint type. Butyl acetate had the highest concentration in both water- and oil-based paints; however, its concentration and proportion were higher in the former (3256 ppb, 65.5%) than in the latter (2449 ppb, 31.1%). Comparing VOC concentration before and after passing through adsorption systems, concentrations of most VOCs were lower at the outlets than the inlets of the adsorption systems, but were found to be high at the outlets in some workshops. These results provide a theoretical basis for developing effective VOC control systems and managing VOC emissions from auto-repair painting workshops.
Collapse
Affiliation(s)
- M Y Song
- Department of Climate & Environmental Research, Seoul Institute of Technology, Seoul, 03909, Korea.
| | - H Chun
- Department of Climate & Environmental Research, Seoul Institute of Technology, Seoul, 03909, Korea
| |
Collapse
|
8
|
Yang S, Perret V, Hager Jörin C, Niculita‐Hirzel H, Goyette Pernot J, Licina D. Volatile organic compounds in 169 energy-efficient dwellings in Switzerland. INDOOR AIR 2020; 30:481-491. [PMID: 32190933 PMCID: PMC7216845 DOI: 10.1111/ina.12667] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 02/20/2020] [Accepted: 03/15/2020] [Indexed: 05/06/2023]
Abstract
Exposure to elevated levels of certain volatile organic compounds (VOCs) in households has been linked to deleterious health effects. This study presents the first large-scale investigation of VOC levels in 169 energy-efficient dwellings in Switzerland. Through a combination of physical measurements and questionnaire surveys, we investigated the influence of diverse building characteristics on indoor VOCs. Among 74 detected compounds, carbonyls, alkanes, and alkenes were the most abundant. Median concentration levels of formaldehyde (14 μg/m3 ), TVOC (212 μg/m3 ), benzene (<0.1 μg/m3 ), and toluene (22 μg/m3 ) were below the upper exposure limits. Nonetheless, 90% and 50% of dwellings exceeded the chronic exposure limits for formaldehyde (9 μg/m3 ) and TVOC (200 μg/m3 ), respectively. There was a strong positive correlation among VOCs that likely originated from common sources. Dwellings built between 1950s and 1990s, and especially, those with attached garages had higher TVOC concentrations. Interior thermal retrofit of dwellings and absence of mechanical ventilation system were associated with elevated levels of formaldehyde, aromatics, and alkanes. Overall, energy-renovated homes had higher levels of certain VOCs compared with newly built homes. The results suggest that energy efficiency measures in dwellings should be accompanied by actions to mitigate VOC exposures as to avoid adverse health outcomes.
Collapse
Affiliation(s)
- Shen Yang
- Human‐Oriented Built Environment LabSchool of ArchitectureCivil and Environmental EngineeringÉcole Polytechnique Fédérale de LausanneLausanneSwitzerland
| | | | - Corinne Hager Jörin
- School of Engineering and Architecture of FribourgHumanTech InstituteHES‐SO University of Applied Sciences and Arts Western SwitzerlandFribourgSwitzerland
| | - Hélène Niculita‐Hirzel
- Department of Health, Work and EnvironmentCenter for Primary Care and Public Health (Unisanté)University of LausanneLausanneSwitzerland
| | - Joëlle Goyette Pernot
- School of Engineering and Architecture of FribourgTransform InstituteWestern Swiss Center for Indoor Air Quality and Radon (croqAIR)HES‐SO University of Applied Sciences and Arts Western SwitzerlandFribourgSwitzerland
| | - Dusan Licina
- Human‐Oriented Built Environment LabSchool of ArchitectureCivil and Environmental EngineeringÉcole Polytechnique Fédérale de LausanneLausanneSwitzerland
| |
Collapse
|
9
|
Even M, Hutzler C, Wilke O, Luch A. Emissions of volatile organic compounds from polymer-based consumer products: Comparison of three emission chamber sizes. INDOOR AIR 2020; 30:40-48. [PMID: 31544292 DOI: 10.1111/ina.12605] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Revised: 08/12/2019] [Accepted: 09/18/2019] [Indexed: 05/06/2023]
Abstract
The ISO 16000 standard series provide guidelines for emission measurements of volatile organic compounds (VOCs) from building materials. However, polymer-based consumer products such as toys may also release harmful substances into indoor air. In such cases, the existing standard procedures are unsuitable for official control laboratories due to high costs for large emission testing chambers. This paper aims at developing and comparing alternative and more competitive methods for the emission testing of consumer products. The influence of the emission chamber size was investigated as smaller chambers are more suited to the common size of consumer products and may help to reduce the costs of testing. Comparison of the performance of a 203 L emission test chamber with two smaller chambers with the capacity of 24 L and 44 mL, respectively, was carried out by using a polyurethane reference material spiked with 14 VOCs during the course of 28 days. The area-specific emission rates obtained in the small chambers were always similar to those of the 203 L reference chamber after a few hours. This implies that smaller chambers can provide at least useful numbers on the extent of polymer-based consumer product emissions into indoor air, thereby supporting meaningful exposure assessments.
Collapse
Affiliation(s)
- Morgane Even
- Department of Chemical and Product Safety, German Federal Institute for Risk Assessment (BfR), Berlin, Germany
| | - Christoph Hutzler
- Department of Chemical and Product Safety, German Federal Institute for Risk Assessment (BfR), Berlin, Germany
| | - Olaf Wilke
- Division 4.2 - Materials and Air Pollutants, Federal Institute for Materials Research and Testing (BAM), Berlin, Germany
| | - Andreas Luch
- Department of Chemical and Product Safety, German Federal Institute for Risk Assessment (BfR), Berlin, Germany
| |
Collapse
|
10
|
|
11
|
Boor BE, Järnström H, Novoselac A, Xu Y. Infant exposure to emissions of volatile organic compounds from crib mattresses. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:3541-3549. [PMID: 24548111 DOI: 10.1021/es405625q] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Infants spend most of their time sleeping and are likely to be exposed to elevated concentrations of chemicals released from their crib mattresses. Small-scale chamber experiments were conducted to determine the area-specific emission rates (SERs) of volatile organic compounds (VOCs) in a collection of twenty new and used crib mattresses. All mattress samples were found to emit VOCs and the mean values of total VOC (TVOC) SERs were 56 μg/m(2)h at 23 °C and 139 μg/m(2)h at 36 °C. TVOC SERs were greater for new mattresses compared to used ones and were influenced by the type of foam material and the presence of mattress cover layer. A variety of VOCs were identified, with polyurethane foam releasing a greater diversity of VOCs compared to polyester foam. Large-scale chamber experiments were conducted with an infant thermal manikin. TVOC concentrations sampled in the breathing zone and interior pore air of the crib mattress foam were found to be greater than the bulk room air by factors in the range of 1.8 to 2.4 and 7.5 to 21, respectively. The results suggest that crib mattresses are an important source of VOCs and infant exposure to VOCs are possibly elevated in their sleep microenvironments.
Collapse
Affiliation(s)
- Brandon E Boor
- Department of Civil, Architectural, and Environmental Engineering, The University of Texas at Austin , Austin 78712, Texas, United States
| | | | | | | |
Collapse
|
12
|
Ayoko GA, Wang H. Volatile Organic Compounds in Indoor Environments. THE HANDBOOK OF ENVIRONMENTAL CHEMISTRY 2014. [DOI: 10.1007/698_2014_259] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
13
|
Richter M, Jann O, Kemski J, Schneider U, Krocker C, Hoffmann B. Determination of radon exhalation from construction materials using VOC emission test chambers. INDOOR AIR 2013; 23:397-405. [PMID: 23374080 DOI: 10.1111/ina.12031] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2012] [Accepted: 01/26/2013] [Indexed: 06/01/2023]
Abstract
The inhalation of (222) Rn (radon) decay products is one of the most important reasons for lung cancer after smoking. Stony building materials are an important source of indoor radon. This article describes the determination of the exhalation rate of stony construction materials by the use of commercially available measuring devices in combination with VOC emission test chambers. Five materials - two types of clay brick, clinker brick, light-weight concrete brick, and honeycomb brick - generally used for wall constructions were used for the experiments. Their contribution to real room concentrations was estimated by applying room model parameters given in ISO 16000-9, RP 112, and AgBB. This knowledge can be relevant, if for instance indoor radon concentration is limited by law. The test set-up used here is well suited for application in test laboratories dealing with VOC emission testing.
Collapse
Affiliation(s)
- M Richter
- Division 4.2 Materials and Air Pollutants, BAM Federal Institute for Materials Research and Testing, Berlin, Germany
| | | | | | | | | | | |
Collapse
|
14
|
Shin SH, Jo WK. Longitudinal variations in indoor VOC concentrations after moving into new apartments and indoor source characterization. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2013; 20:3696-3707. [PMID: 23143824 DOI: 10.1007/s11356-012-1296-z] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2012] [Accepted: 10/29/2012] [Indexed: 06/01/2023]
Abstract
This study examined the indoor concentrations of a wide range of volatile organic compounds (VOCs) in currently built new apartments every month over a 24-month period and the source characteristics of indoor VOCs. The indoor total VOC (TVOC) concentrations exhibited a decreasing tendency over the 24-month follow-up period. Similar to TVOCs, the median indoor concentrations of 33 of 40 individual VOCs (all except for naphthalene and six halogenated VOCs) revealed decreasing tendencies. In contrast, the indoor concentrations of the six halogenated VOCs did not reveal any definite trend with time. Moreover, the indoor concentrations of those halogenated VOCs were similar to the outdoor concentrations, suggesting the absence of any notable indoor sources of halogenated VOCs. For naphthalene (NT), the indoor concentrations were significantly higher than the outdoor concentrations, suggesting the presence of indoor NT source(s). The floor/wall coverings (39 %) were the most influential indoor source of indoor VOCs, followed by household cleaning products (32 %), wood paneling/furniture (17 %), paints (7 %), and moth repellents (5 %).
Collapse
Affiliation(s)
- Seung-Ho Shin
- Department of Environmental Engineering, Kyungpook National University, Daegu, 702-701, South Korea
| | | |
Collapse
|
15
|
Marć M, Zabiegała B, Namieśnik J. Miniaturized Passive Emission Chambers for In Situ Measurement of Emissions of Volatile Organic Compounds. Crit Rev Anal Chem 2013. [DOI: 10.1080/10408347.2012.744888] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Mariusz Marć
- a Department of Analytical Chemistry , Gdansk University of Technology , Gdansk , Poland
| | - Bożena Zabiegała
- a Department of Analytical Chemistry , Gdansk University of Technology , Gdansk , Poland
| | - Jacek Namieśnik
- a Department of Analytical Chemistry , Gdansk University of Technology , Gdansk , Poland
| |
Collapse
|
16
|
Shin SH, Jo WK. Volatile organic compound concentrations, emission rates, and source apportionment in newly-built apartments at pre-occupancy stage. CHEMOSPHERE 2012; 89:569-578. [PMID: 22698369 DOI: 10.1016/j.chemosphere.2012.05.054] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2011] [Revised: 02/07/2012] [Accepted: 05/16/2012] [Indexed: 06/01/2023]
Abstract
The present study investigated the indoor concentrations of selected volatile organic compounds (VOCs) and formaldehyde and their indoor emission characteristics in newly-built apartments at the pre-occupancy stage. In total, 107 apartments were surveyed for indoor and outdoor VOC concentrations in two metropolitan cities and one rural area in Korea. A mass balanced model was used to estimate surface area-specific emission rates of individual VOCs and formaldehyde. Seven (benzene, ethyl benzene, toluene, m,p-xylene, o-xylene, n-hexane, and n-heptane) of 40 target compounds were detectable in all indoor air samples, whereas the first five were detected in all outdoor air samples. Formaldehyde was also predominant in the indoor air samples, with a high detection frequency of 96%. The indoor concentrations were significantly higher than the outdoor concentrations for aromatics, alcohols, terpenes, and ketones. However, six halogenated VOCs exhibited similar concentrations for indoor and outdoor air samples, suggesting that they are not major components emitted from building materials. It was also suggested that a certain portion of the apartments surveyed were constructed by not following the Korean Ministry of Environment guidelines for formaldehyde emissions. Toluene exhibited the highest emission rate with a median value of 138 μg m(-2) h(-1). The target compounds with median emission rates greater than 20 μg m(-2) h(-1) were toluene, 1-propanol, formaldehyde, and 2-butanone. The wood panels/vinyl floor coverings were the largest indoor pollutant source, followed by floorings, wall coverings, adhesives, and paints. The wood panels/vinyl floor coverings contributed nearly three times more to indoor VOC concentrations than paints.
Collapse
Affiliation(s)
- Seung H Shin
- Department of Environmental Engineering, Kyungpook National University, Daegu 702-701, Republic of Korea
| | | |
Collapse
|
17
|
Marć M, Zabiegała B, Namieśnik J. Testing and sampling devices for monitoring volatile and semi-volatile organic compounds in indoor air. Trends Analyt Chem 2012. [DOI: 10.1016/j.trac.2011.09.006] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
18
|
Ho DX, Kim KH, Sohn JR, Oh YH, Ahn JW. Emission rates of volatile organic compounds released from newly produced household furniture products using a large-scale chamber testing method. ScientificWorldJournal 2011; 11:1597-622. [PMID: 22125421 PMCID: PMC3201684 DOI: 10.1100/2011/650624] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2011] [Revised: 08/12/2011] [Accepted: 08/12/2011] [Indexed: 11/17/2022] Open
Abstract
The emission rates of volatile organic compounds (VOCs) were measured to investigate the emission characteristics of five types of common furniture products using a 5 m3 size chamber at 25°C and 50% humidity. The results indicated that toluene and α-pinene are the most dominant components. The emission rates of individual components decreased constantly through time, approaching the equilibrium emission level. The relative ordering of their emission rates, if assessed in terms of total VOC (TVOC), can be arranged as follows: dining table > sofa > desk chair > bedside table > cabinet. If the emission rates of VOCs are examined between different chemical groups, they can also be arranged in the following order: aromatic (AR) > terpenes (TER) > carbonyl (CBN) > others > paraffin (PR) > olefin (HOL) > halogenated paraffin (HPR). In addition, if emission strengths are compared between coated and uncoated furniture, there is no significant difference in terms of emission magnitude. Our results indicate that the emission characteristics of VOC are greatly distinguished between different furniture products in terms of relative dominance between different chemicals.
Collapse
Affiliation(s)
- Duy Xuan Ho
- Department of Environment & Energy, Sejong University, Seoul 143-747, Republic of Korea
| | | | | | | | | |
Collapse
|
19
|
Chang YM, Hu WH, Fang WB, Chen SS, Chang CT, Ching HW. A study on dynamic volatile organic compound emission characterization of water-based paints. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 2011; 61:35-45. [PMID: 21305886 DOI: 10.3155/1047-3289.61.1.35] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Volatile organic compounds (VOCs) emitted from surface coatings have caused growing public concern for air quality. Even the low-emitted VOC impact from water-based paints on indoor air quality in urban areas has caused concern. This paper presents experimental data using a mathematical model to simulate dynamic VOC emissions from water-based paints that is based on mass transfer and molecular diffusion theories. A series of field-analogous experiments were carried out to continuously measure the VOCs emitted from two typical water-based paints using a gas chromatography-flame-ionization detector monitor in an artificial wind tunnel system. In the study cases, the mass flux of VOCs emitted from the water-based paints was up to 50 microg/m2sec. It was found that the time needed to completely emit VOCs from water-based paints is just hundreds of seconds. However, the order of magnitude of the VOC emission rate from water-based paints is not lower than that from some dry building materials and solvent-based paints. The experimental data were used to produce a useful semiempirical correlation to estimate the VOC emission rates for water-based paints. This correlation is valid under appropriate conditions as suggested by this work with a statistical deviation of +/- 7.6%. With this correlation, it seems feasible to predict the dynamic emission rates for VOCs during a painting process. This correlation is applicable for assessing the hazardous air pollutant impact on indoor air quality or for environmental risk assessment. Associated with the dynamic VOC emission characterization, the air-exchange rate effect on the VOC emission rates is also discussed.
Collapse
Affiliation(s)
- Yu-Min Chang
- Graduate Institute of Environmental Engineering and Management, National Taipei University of Technology, Taipei, Taiwan, Republic of China.
| | | | | | | | | | | |
Collapse
|
20
|
Kim S, Choi YK, Park KW, Kim JT. Test methods and reduction of organic pollutant compound emissions from wood-based building and furniture materials. BIORESOURCE TECHNOLOGY 2010; 101:6562-6568. [PMID: 20409705 DOI: 10.1016/j.biortech.2010.03.059] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2009] [Revised: 03/02/2010] [Accepted: 03/12/2010] [Indexed: 05/29/2023]
Abstract
This paper reviews different methods for the analysis of formaldehyde and volatile organic compounds (VOCs) from wood-based panel materials for furniture and building interiors and highlights research on reduction of emission from wood-based panels that can adversely affect indoor air quality. In Korea, standard test methods have been developed to determine formaldehyde and VOC emissions from building products, and the Ministry of Environment regulates the use of building materials with pollutant emissions. Desiccator and perforator methods are being used for formaldehyde and the chamber and field and laboratory emission cell (FLEC) methods for VOC and formaldehyde emissions. The VOC analyzer is a suitable pre-test method for application as a total VOC (TVOC) emission test and bake-out is a useful method to reduce TVOC and formaldehyde emissions from furniture materials in indoor environments.
Collapse
Affiliation(s)
- Sumin Kim
- School of Architecture, Soongsil University, Seoul, Republic of Korea.
| | | | | | | |
Collapse
|
21
|
Kim KW, Kim S, Kim HJ, Park JC. Formaldehyde and TVOC emission behaviors according to finishing treatment with surface materials using 20 L chamber and FLEC. JOURNAL OF HAZARDOUS MATERIALS 2010; 177:90-94. [PMID: 19850406 DOI: 10.1016/j.jhazmat.2009.09.060] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2009] [Revised: 09/02/2009] [Accepted: 09/14/2009] [Indexed: 05/28/2023]
Abstract
Formaldehyde and TVOC are emitted from wood-based panels that are made using wood particles, wood fiber, wood chips and formaldehyde-based resins. This study examined the formaldehyde and TVOC emission behavior of medium density fiberboard (MDF) overlaid with three types of uncoated lignocellulosic surface materials (oak decorative veneer, low pressure melamine impregnated paper and high pressure melamine impregnated paper) and four types of coated surface materials (coated paper, two types of finishing foils, and PVC) using the Field and Laboratory Emission Cell (FLEC) method and a 20 L small chamber method. The uncoated lignocellulosic surface materials exhibited lower formaldehyde and TVOC emission levels. The coated surface materials did not show reduced TVOC emissions but the formaldehyde emission was reduced in the 20 L small chamber test. In the FLEC test, both the uncoated lignocellulosic surface materials and coated surface materials showed lower TVOC and formaldehyde emissions from MDF.
Collapse
Affiliation(s)
- Ki-Wook Kim
- Laboratory of Adhesion & Bio-Composites, Program in Environmental Materials Science, Seoul National University, Seoul 151-921, Republic of Korea
| | | | | | | |
Collapse
|
22
|
Herbarth O, Matysik S. Decreasing concentrations of volatile organic compounds (VOC) emitted following home renovations. INDOOR AIR 2010; 20:141-6. [PMID: 20409192 DOI: 10.1111/j.1600-0668.2009.00631.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Volatile organic compounds (VOC) play an important role indoors since they have been linked to health symptoms and disorders. Particularly, after renovation activities, high indoor VOC concentrations have been observed. The study will give an indication, for the first time under real conditions, of the to-be-expected time frame for renovation-derived indoor pollution decreases when the exposure to it will reach a reference level. The decrease in the concentrations of investigated 26 VOC after renovations was assessed under real-life situations. Both the daily VOC concentration was measured by active sampling for 30 days in selected homes which had undergone various renovations and, as part of an epidemiologic study, the same VOC were collected monthly using passive samplers in 243 homes. An exponential function was used to interpret the concentration decay. The average time range which has to elapse following renovation activities before a guideline value or reference load is reached showed a time range between 2 and 8 weeks. This waiting time had at least be applicable to public buildings and institutions (especially relevant in case of nurseries, playschools etc.) with increasingly being implemented in private homes as well. Practical Implications After renovation an optimal waiting period had to be up to 60 days before the rooms will be used again. Fourteen days are possible, but increased ventilation is recommended. These had to be applicable at least for public buildings used by risk groups like young children. Renovations had to be carried out in summer season to ensure optimal ventilation to reduce the waiting time.
Collapse
Affiliation(s)
- O Herbarth
- Faculty of Medicine, Environmental Medicine and Hygiene, University Leipzig, 04103 Leipzig, Germany.
| | | |
Collapse
|
23
|
Schuchardt S, Kruse H. Quantitative volatile metabolite profiling of common indoor fungi: relevancy for indoor air analysis. J Basic Microbiol 2009; 49:350-62. [DOI: 10.1002/jobm.200800152] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
24
|
Kim S, Kim JA, An JY, Kim HJ, Kim SD, Park JC. TVOC and formaldehyde emission behaviors from flooring materials bonded with environmental-friendly MF/PVAc hybrid resins. INDOOR AIR 2007; 17:404-15. [PMID: 17880636 DOI: 10.1111/j.1600-0668.2007.00488.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
UNLABELLED Polyvinyl acetate (PVAc) was added as a replacement for melamine-formaldehyde (MF) resin in the formaldehyde-based resin system to reduce formaldehyde and volatile organic compound (VOC) emissions from the adhesives used between plywoods and fancy veneers. A variety of techniques, including 20-l chamber, field and laboratory emission cell (FLEC), VOC analyzer and standard formaldehyde emission test (desiccator method), were used to determine the formaldehyde and VOC emissions from engineered flooring bonded with five different MF resin and PVAc blends at MF/PVAc ratios of 100:0, 70:30, 50:50, 30:70 and 0:100. Although urea-formaldehyde (UF) resin had the highest formaldehyde emission, the emission as determined by desiccator method was reduced by exchanging with MF resin. Furthermore, the formaldehyde emission level was decreased with increasing addition of PVAc as the replacement for MF resin. UF resin in the case of beech was over 5.0 mg/l, which exceeded E2 (1.5-5.0 mg/l) grade. However, MF30:PVAc70 was <or=E1 (below 1.5 mg/l) grade. Because formaldehyde emission is caused by formaldehyde-based resin, the engineered floorings bonded with PVAc only had emissions of just 0.25 mg/l. The results of formaldehyde emission by the 20-l small-chamber and FLEC methods showed a similar tendency with those from the desiccator method. After the replacement of UF resin by MF resin, PVAc addition further reduced formaldehyde emission. With increasing installation time, formaldehyde emission factors (EFs) were decreased. Furthermore, the results of the desiccator method correlated with those of the 20-l chamber and FLEC methods. VOC emission results by 20-l small-chamber and FLEC methods were similar to the formaldehyde and aldehyde emission results. VOCs were calculated between C6 and C16 as total VOC (TVOC). The TVOC EF results by 20-l small-chamber and FLEC methods were comparable with that of formaldehyde emission by FLEC. Although the major emitted harmful gas from wood-based composites was formaldehyde, it was followed by VOC emission. Although it was hard to compare directly the 20-l chamber and FLEC results because the data were based on the sum of only four VOC compounds, the VOC analyzer can be applied as a pre-test method for TVOC emission test. The TVOC emission results were also similar to the FLEC results. Due to its good correlation with the TVOC emission levels obtained from the standard desiccator, FLEC and 20-l chamber methods, the VOC analyzer can be successfully applied to the measurement of TVOC emissions from adhesives used in building materials. PRACTICAL IMPLICATIONS This paper presents TVOC and formaldehyde emission behaviors from the engineered floorings that used in Korean housing recently. To reduce emissions, MF/PVAc hybrid resins were used as bonding material. Normally, TVOC and formaldehyde emissions in indoor conditions are caused by interior materials. The results explained 'materials control' of interior materials are the first way to improve indoor air quality. There is a need to study about environmental-friendly materials for solving indoor air quality problem.
Collapse
Affiliation(s)
- Sumin Kim
- Laboratory of Adhesion and Bio-composites, Major in Environmental Materials Science, Seoul National University, Seoul, South Korea
| | | | | | | | | | | |
Collapse
|