Stowasser M, Ahmed AH, Cowley D, Wolley M, Guo Z, McWhinney BC, Ungerer JP, Gordon RD. Comparison of Seated With Recumbent Saline Suppression Testing for the Diagnosis of Primary Aldosteronism.
J Clin Endocrinol Metab 2018;
103:4113-4124. [PMID:
30239841 DOI:
10.1210/jc.2018-01394]
[Citation(s) in RCA: 54] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2018] [Accepted: 09/13/2018] [Indexed: 02/13/2023]
Abstract
CONTEXT
Failure of plasma aldosterone suppression during fludrocortisone suppression testing (FST) or saline suppression testing (SST) confirms primary aldosteronism (PA). Aldosterone is often higher upright than recumbent in PA; upright levels are used during FST. In a pilot study (24 patients with PA), seated saline suppression testing (SSST) was more sensitive than recumbent saline suppression testing (RSST).
OBJECTIVE, DESIGN, AND PATIENTS
The current validation study involved 100 patients who underwent FST, RSST, and SSST, eight before and after unilateral adrenalectomy. Of the 108 FSTs, 73 confirmed and 18 excluded PA. Four patients with inconclusive FST lateralized on adrenal venous sampling, making a total of 77 with PA.
RESULTS
The area under the receiver operating characteristic (ROC) curve was greater for SSST than RSST (0.96 vs. 0.80; P < 0.01). ROC analysis predicted optimal cutoff aldosterone levels of 162 pmol/L for SSST and 106 pmol/L for RSST. At these cutoffs, SSST showed high sensitivity for PA (87%) that markedly exceeded that for RSST (38%; P < 0.001) but similar specificity (94 vs. 94%; not significant). SSST was more sensitive than RSST in detecting both unilateral (n = 28, 93% vs. 68%, P < 0.05) and bilateral (n = 40, 85% vs. 20%, P < 0.001) forms of PA. Only three SSST (vs. 9 RSST and 17 FST) results were inconclusive.
CONCLUSIONS
SSST is highly sensitive and superior to RSST in identifying both unilateral and bilateral forms of PA and has a low rate of false positives and inconclusive results. It therefore offers a reliable and much less complicated and expensive alternative to FST for confirming PA.