Brandenbarg P, Hoekstra F, Barakou I, Seves BL, Hettinga FJ, Hoekstra T, van der Woude LHV, Dekker R, Krops LA. Measurement properties of device-based physical activity instruments in ambulatory adults with physical disabilities and/or chronic diseases: a scoping review. BMC Sports Sci Med Rehabil 2023; 15:115. [PMID: 37735403 PMCID: PMC10512652 DOI: 10.1186/s13102-023-00717-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Accepted: 08/22/2023] [Indexed: 09/23/2023]
Abstract
BACKGROUND People with physical disabilities and/or chronic diseases tend to have an inactive lifestyle. Monitoring physical activity levels is important to provide insight on how much and what types of activities people with physical disabilities and/or chronic diseases engage in. This information can be used as input for interventions to promote a physically active lifestyle. Therefore, valid and reliable physical activity measurement instruments are needed. This scoping review aims 1) to provide a critical mapping of the existing literature and 2) directions for future research on measurement properties of device-based instruments assessing physical activity behavior in ambulant adults with physical disabilities and/or chronic diseases. METHODS Four databases (MEDLINE, CINAHL, Web of Science, Embase) were systematically searched from 2015 to April 16th 2023 for articles investigating measurement properties of device-based instruments assessing physical activity in ambulatory adults with physical disabilities and/or chronic diseases. For the majority, screening and selection of eligible studies were done in duplicate. Extracted data were publication data, study data, study population, device, studied measurement properties and study outcome. Data were synthesized per device. RESULTS One hundred three of 21566 Studies were included. 55 Consumer-grade and 23 research-grade devices were studied on measurement properties, using 14 different physical activity outcomes, in 23 different physical disabilities and/or chronic diseases. ActiGraph (n = 28) and Fitbit (n = 39) devices were most frequently studied. Steps (n = 68) was the most common used physical activity outcome. 97 studies determined validity, 11 studies reliability and 6 studies responsiveness. CONCLUSION This scoping review shows a large variability in research on measurement properties of device-based instruments in ambulatory adults with physical disabilities and/or chronic diseases. The variability highlights a need for standardization of and consensus on research in this field. The review provides directions for future research.
Collapse
Affiliation(s)
- Pim Brandenbarg
- Department of Human Movement Sciences, University of Groningen, University Medical Center Groningen, Groningen, 9700 RB, The Netherlands.
- Department of Rehabilitation Medicine, University of Groningen, University Medical Center Groningen, Groningen, 9700 RB, The Netherlands.
| | - Femke Hoekstra
- Department of Human Movement Sciences, University of Groningen, University Medical Center Groningen, Groningen, 9700 RB, The Netherlands
- Department of Rehabilitation Medicine, University of Groningen, University Medical Center Groningen, Groningen, 9700 RB, The Netherlands
- School of Health and Exercise Sciences, University of British Columbia Okanagan, Kelowna, BC, V1V 1V7, Canada
| | - Ioulia Barakou
- Department of Human Movement Sciences, University of Groningen, University Medical Center Groningen, Groningen, 9700 RB, The Netherlands
| | - Bregje L Seves
- Department of Human Movement Sciences, University of Groningen, University Medical Center Groningen, Groningen, 9700 RB, The Netherlands
- Department of Rehabilitation Medicine, University of Groningen, University Medical Center Groningen, Groningen, 9700 RB, The Netherlands
| | - Florentina J Hettinga
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle, NE1 8ST, UK
| | - Trynke Hoekstra
- Department of Rehabilitation Medicine, University of Groningen, University Medical Center Groningen, Groningen, 9700 RB, The Netherlands
- Department of Health Sciences and Amsterdam Public Health Research Institute, Vrije Universiteit Amsterdam, Amsterdam, 1081 BT, The Netherlands
| | - Lucas H V van der Woude
- Department of Human Movement Sciences, University of Groningen, University Medical Center Groningen, Groningen, 9700 RB, The Netherlands
- Department of Rehabilitation Medicine, University of Groningen, University Medical Center Groningen, Groningen, 9700 RB, The Netherlands
| | - Rienk Dekker
- Department of Rehabilitation Medicine, University of Groningen, University Medical Center Groningen, Groningen, 9700 RB, The Netherlands
| | - Leonie A Krops
- Department of Rehabilitation Medicine, University of Groningen, University Medical Center Groningen, Groningen, 9700 RB, The Netherlands
| |
Collapse
|
2
|
Limb accelerations during sleep are related to measures of strength, sensation, and spasticity among individuals with spinal cord injury. J Neuroeng Rehabil 2022; 19:118. [PMID: 36329467 PMCID: PMC9635075 DOI: 10.1186/s12984-022-01090-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 09/08/2022] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND To evaluate the relationship between measures of neuromuscular impairment and limb accelerations (LA) collected during sleep among individuals with chronic spinal cord injury (SCI) to provide evidence of construct and concurrent validity for LA as a clinically meaningful measure. METHODS The strength (lower extremity motor score), sensation (summed lower limb light touch scores), and spasticity (categorized lower limb Modified Ashworth Scale) were measured from 40 adults with chronic (≥ 1 year) SCI. Demographics, pain, sleep quality, and other covariate or confounding factors were measured using self-report questionnaires. Each participant then wore ActiGraph GT9X Link accelerometers on their ankles and wrist continuously for 1-5 days to measure LA from movements during sleep. Regression models with built-in feature selection were used to determine the most relevant LA features and the association to each measure of impairment. RESULTS LA features were related to measures of impairment with models explaining 69% and 73% of the variance (R²) in strength and sensation, respectively, and correctly classifying 81.6% (F1-score = 0.814) of the participants into spasticity categories. The most commonly selected LA features included measures of power and frequency (frequency domain), movement direction (correlation between axes), consistency between movements (relation to recent movements), and wavelet energy (signal characteristics). Rolling speed (change in angle of inclination) and movement smoothness (median crossings) were uniquely associated with strength. When LA features were included, an increase of 72% and 222% of the variance was explained for strength and sensation scores, respectively, and there was a 34% increase in spasticity classification accuracy compared to models containing only covariate features such as demographics, sleep quality, and pain. CONCLUSION LA features have shown evidence of having construct and concurrent validity, thus demonstrating that LA are a clinically-relevant measure related to lower limb strength, sensation, and spasticity after SCI. LA may be useful as a more detailed measure of impairment for applications such as clinical prediction models for ambulation.
Collapse
|
3
|
Ngueleu AM, Barthod C, Best KL, Routhier F, Otis M, Batcho CS. Criterion validity of ActiGraph monitoring devices for step counting and distance measurement in adults and older adults: a systematic review. J Neuroeng Rehabil 2022; 19:112. [PMID: 36253787 PMCID: PMC9575229 DOI: 10.1186/s12984-022-01085-5] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Accepted: 09/21/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Wearable activity monitors such as ActiGraph monitoring devices are widely used, especially in research settings. Various research studies have assessed the criterion validity of ActiGraph devices for step counting and distance estimation in adults and older adults. Although several studies have used the ActiGraph devices as a reference system for activity monitoring, there is no summarized evidence of the psychometric properties. The main objective of this systematic review was to summarize evidence related to the criterion validity of ActiGraph monitoring devices for step counting and distance estimation in adults and/or older adults. METHODS Literature searches were conducted in six databases (Medline (OVID), Embase, IEEExplore, CINAHL, Engineering Village and Web of Science). Two reviewers independently conducted selection, a quality analysis of articles (using COSMIN and MacDermid's grids) and data extraction. RESULTS This review included 21 studies involving 637 participants (age 30.3 ± 7.5 years (for adults) and 82.7 ± 3.3 years (for older adults)). Five ActiGraph devices (7164, GT1M, wGTX +, GT3X +/wGT3X + and wGT3X - BT) were used to collect data at the hip, wrist and ankle to assess various walking and running speeds (ranging from 0.2 m/s to 4.44 m/s) over durations of 2 min to 3 days (13 h 30 mins per day) for step counting and distance estimation. The ActiGraph GT3X +/wGT3X + and wGT3X - BT had better criterion validity than the ActiGraph 7164, wGTX + and GT1M according to walking and running speeds for step counting. Validity of ActiGraph wGT3X + was good for distance estimation. CONCLUSION The ActiGraph wGT3X - BT and GT3X +/wGT3X + have good criterion validity for step counting, under certain conditions related to walking speeds, positioning and data processing.
Collapse
Affiliation(s)
- Armelle-Myriane Ngueleu
- Centre for Interdisciplinary Research in Rehabilitation and Social Integration, Centre intégré universitaire de santé et de services sociaux de la Capitale-Nationale, Québec City, Québec, Canada.,Department of Rehabilitation, Faculty of Medicine, Université Laval, Québec City, Québec, Canada
| | - Corentin Barthod
- Centre for Interdisciplinary Research in Rehabilitation and Social Integration, Centre intégré universitaire de santé et de services sociaux de la Capitale-Nationale, Québec City, Québec, Canada.,Department of Rehabilitation, Faculty of Medicine, Université Laval, Québec City, Québec, Canada
| | - Krista Lynn Best
- Centre for Interdisciplinary Research in Rehabilitation and Social Integration, Centre intégré universitaire de santé et de services sociaux de la Capitale-Nationale, Québec City, Québec, Canada.,Department of Rehabilitation, Faculty of Medicine, Université Laval, Québec City, Québec, Canada
| | - François Routhier
- Centre for Interdisciplinary Research in Rehabilitation and Social Integration, Centre intégré universitaire de santé et de services sociaux de la Capitale-Nationale, Québec City, Québec, Canada.,Department of Rehabilitation, Faculty of Medicine, Université Laval, Québec City, Québec, Canada
| | - Martin Otis
- Automation and Interactive Robotic Laboratory (AIRL), Department of Applied Science, Université de Quebec À Chicoutimi, 555 Blvd of University, Chicoutimi, Québec, Canada
| | - Charles Sèbiyo Batcho
- Centre for Interdisciplinary Research in Rehabilitation and Social Integration, Centre intégré universitaire de santé et de services sociaux de la Capitale-Nationale, Québec City, Québec, Canada. .,Department of Rehabilitation, Faculty of Medicine, Université Laval, Québec City, Québec, Canada.
| |
Collapse
|
4
|
Lonini L, Shawen N, Hoppe-Ludwig S, Deems-Dluhy S, Mummidisetty CK, Eisenberg Y, Jayaraman A. Combining Accelerometer and GPS Features to Evaluate Community Mobility in Knee Ankle Foot Orthoses (KAFO) Users. IEEE Trans Neural Syst Rehabil Eng 2021; 29:1386-1393. [PMID: 34252030 PMCID: PMC8363134 DOI: 10.1109/tnsre.2021.3096434] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
Orthotic and assistive devices such as knee ankle foot orthoses (KAFO), come in a variety of forms and fits, with several levels of available features that could help users perform daily activities more naturally. However, objective data on the actual use of these devices outside of the research lab is usually not obtained. Such data could enhance traditional lab-based outcome measures and inform clinical decision-making when prescribing new orthotic and assistive technology. Here, we link data from a GPS unit and an accelerometer mounted on the orthotic device to quantify its usage in the community and examine the correlations with clinical metrics. We collected data from 14 individuals over a period of 2 months as they used their personal KAFO first, and then a novel research KAFO; for each device we quantified number of steps, cadence, time spent at community locations and time wearing the KAFO at those locations. Sensor-derived metrics showed that mobility patterns differed widely between participants (mean steps: 591.3, SD =704.2). The novel KAFO generally enabled participants to walk faster during clinical tests ( ∆6 Minute-Walk-Test=71.5m, p=0.006). However, some participants wore the novel device less often despite improved performance on these clinical measures, leading to poor correlation between changes in clinical outcome measures and changes in community mobility ( ∆6 Minute-Walk-Test - ∆ Community Steps: r=0.09, p=0.76). Our results suggest that some traditional clinical outcome measures may not be associated with the actual wear time of an assistive device in the community, and obtaining personalized data from real-world use through wearable technology is valuable.
Collapse
|
5
|
Rigot SK, Boninger ML, Ding D, McKernan G, Field-Fote EC, Hoffman J, Hibbs R, Worobey LA. Toward Improving the Prediction of Functional Ambulation After Spinal Cord Injury Though the Inclusion of Limb Accelerations During Sleep and Personal Factors. Arch Phys Med Rehabil 2021; 103:676-687.e6. [PMID: 33839107 DOI: 10.1016/j.apmr.2021.02.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2020] [Revised: 01/21/2021] [Accepted: 02/07/2021] [Indexed: 11/02/2022]
Abstract
OBJECTIVE To determine if functional measures of ambulation can be accurately classified using clinical measures; demographics; personal, psychosocial, and environmental factors; and limb accelerations (LAs) obtained during sleep among individuals with chronic, motor incomplete spinal cord injury (SCI) in an effort to guide future, longitudinal predictions models. DESIGN Cross-sectional, 1-5 days of data collection. SETTING Community-based data collection. PARTICIPANTS Adults with chronic (>1 year), motor incomplete SCI (N=27). INTERVENTIONS Not applicable. MAIN OUTCOME MEASURES Ambulatory ability based on the 10-m walk test (10MWT) or 6-minute walk test (6MWT) categorized as nonambulatory, household ambulator (0.01-0.44 m/s, 1-204 m), or community ambulator (>0.44 m/s, >204 m). A random forest model classified ambulatory ability using input features including clinical measures of strength, sensation, and spasticity; demographics; personal, psychosocial, and environmental factors including pain, environmental factors, health, social support, self-efficacy, resilience, and sleep quality; and LAs measured during sleep. Machine learning methods were used explicitly to avoid overfitting and minimize the possibility of biased results. RESULTS The combination of LA, clinical, and demographic features resulted in the highest classification accuracies for both functional ambulation outcomes (10MWT=70.4%, 6MWT=81.5%). Adding LAs, personal, psychosocial, and environmental factors, or both increased the accuracy of classification compared with the clinical/demographic features alone. Clinical measures of strength and sensation (especially knee flexion strength), LA measures of movement smoothness, and presence of pain and comorbidities were among the most important features selected for the models. CONCLUSIONS The addition of LA and personal, psychosocial, and environmental features increased functional ambulation classification accuracy in a population with incomplete SCI for whom improved prognosis for mobility outcomes is needed. These findings provide support for future longitudinal studies that use LA; personal, psychosocial, and environmental factors; and advanced analyses to improve clinical prediction rules for functional mobility outcomes.
Collapse
Affiliation(s)
- Stephanie K Rigot
- Rehab Neural Engineering Labs, University of Pittsburgh, Pittsburgh, PA; Human Engineering Research Laboratories, Veterans Affairs Pittsburgh Healthcare System, Pittsburgh, PA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA
| | - Michael L Boninger
- Rehab Neural Engineering Labs, University of Pittsburgh, Pittsburgh, PA; Human Engineering Research Laboratories, Veterans Affairs Pittsburgh Healthcare System, Pittsburgh, PA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA; Rehabilitation Science and Technology, University of Pittsburgh, Pittsburgh, PA; Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA
| | - Dan Ding
- Human Engineering Research Laboratories, Veterans Affairs Pittsburgh Healthcare System, Pittsburgh, PA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA; Rehabilitation Science and Technology, University of Pittsburgh, Pittsburgh, PA
| | - Gina McKernan
- Human Engineering Research Laboratories, Veterans Affairs Pittsburgh Healthcare System, Pittsburgh, PA; Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA
| | - Edelle C Field-Fote
- Crawford Research Institute, Shepherd Center, Atlanta, GA; Division of Physical Therapy, Department of Rehabilitation Medicine, Emory University School of Medicine, Atlanta, GA; Program in Applied Physiology, School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA
| | - Jeanne Hoffman
- Department of Rehabilitation Medicine, University of Washington School of Medicine, Seattle, WA
| | - Rachel Hibbs
- Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA; Physical Therapy, University of Pittsburgh, Pittsburgh, PA
| | - Lynn A Worobey
- Rehab Neural Engineering Labs, University of Pittsburgh, Pittsburgh, PA; Human Engineering Research Laboratories, Veterans Affairs Pittsburgh Healthcare System, Pittsburgh, PA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA; Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA; Physical Therapy, University of Pittsburgh, Pittsburgh, PA.
| |
Collapse
|
6
|
Quantifying Step Count and Oxygen Consumption with Portable Technology during the 2-Min Walk Test in People with Lower Limb Amputation. SENSORS 2021; 21:s21062080. [PMID: 33809581 PMCID: PMC7999204 DOI: 10.3390/s21062080] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2021] [Revised: 03/03/2021] [Accepted: 03/15/2021] [Indexed: 12/17/2022]
Abstract
Step counts and oxygen consumption have yet to be reported during the 2-min walk test (2MWT) test in persons with lower-limb amputations (LLA). The purpose of this study was to determine step counts and oxygen consumption during the 2MWT in LLA. Thirty-five men and women walked for two minutes as quickly as possible while wearing activity monitors (ActiGraph Link on the wrist (LW) and ankle (LA), Garmin vivofit®3 on the wrist (VW) and ankle (VA), and a modus StepWatch on the ankle (SA), and a portable oxygen analyzer. The StepWatch on the ankle (SA) and the vivofit3 on the wrist (VW) had the least error and best accuracy of the activity monitors studied. While there were no significant differences in distance walked, oxygen consumption (VO2) or heart rate (HR) between sexes or level of amputation (p > 0.05), females took significantly more steps than males (p = 0.034), and those with unilateral transfemoral amputations took significantly fewer steps than those with unilateral transtibial amputations (p = 0.023). The VW and SA provided the most accurate step counts among the activity monitors and were not significantly different than hand counts. Oxygen consumption for all participants during the 2MWT was 8.9 ± 2.9 mL/kg/min, which is lower than moderate-intensity activity. While some may argue that steady-state activity has not yet been reached in the 2MWT, it may also be possible participants are not walking as fast as they can, thereby misclassifying their performance to a lower standard.
Collapse
|
7
|
Mikkelsen MLK, Berg-Beckhoff G, Frederiksen P, Horgan G, O’Driscoll R, Palmeira AL, Scott SE, Stubbs J, Heitmann BL, Larsen SC. Estimating physical activity and sedentary behaviour in a free-living environment: A comparative study between Fitbit Charge 2 and Actigraph GT3X. PLoS One 2020; 15:e0234426. [PMID: 32525912 PMCID: PMC7289355 DOI: 10.1371/journal.pone.0234426] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Accepted: 05/25/2020] [Indexed: 12/27/2022] Open
Abstract
BACKGROUND Activity trackers such as the Fitbit Charge 2 enable users and researchers to monitor physical activity in daily life, which could be beneficial for changing behaviour. However, the accuracy of the Fitbit Charge 2 in a free-living environment is largely unknown. OBJECTIVE To investigate the agreement between Fitbit Charge 2 and ActiGraph GT3X for the estimation of steps, energy expenditure, time in sedentary behaviour, and light and moderate-to-vigorous physical activity under free-living conditions, and further examine to what extent placing the ActiGraph on the wrist as opposed to the hip would affect the findings. METHODS 41 adults (n = 10 males, n = 31 females) were asked to wear a Fitbit Charge 2 device and two ActiGraph GT3X devices (one on the hip and one on the wrist) for seven consecutive days and fill out a log of wear times. Agreement was assessed through Bland-Altman plots combined with multilevel analysis. RESULTS The Fitbit measured 1,492 steps/day more than the hip-worn ActiGraph (limits of agreement [LoA] = -2,250; 5,234), while for sedentary time, it measured 25 min/day less (LoA = -137; 87). Both Bland-Altman plots showed fixed bias. For time in light physical activity, the Fitbit measured 59 min/day more (LoA = -52;169). For time in moderate-to-vigorous physical activity, the Fitbit measured 31 min/day less (LoA = -132; 71) and for activity energy expenditure it measured 408 kcal/day more than the hip-worn ActiGraph (LoA = -385; 1,200). For the two latter outputs, the plots indicated proportional bias. Similar or more pronounced discrepancies, mostly in opposite direction, appeared when comparing to the wrist-worn ActiGraph. CONCLUSION Moderate to substantial differences between devices were found for most outputs, which could be due to differences in algorithms. Caution should be taken if replacing one device with another and when comparing results.
Collapse
Affiliation(s)
- Marie-Louise K. Mikkelsen
- Research Unit for Dietary Studies, The Parker Institute, Bispebjerg and Frederiksberg Hospital, The Capital Region, København, Denmark
| | | | - Peder Frederiksen
- Research Unit for Dietary Studies, The Parker Institute, Bispebjerg and Frederiksberg Hospital, The Capital Region, København, Denmark
| | - Graham Horgan
- Biomathematics & Statistics Scotland (James Hutton Institute), Aberdeen, Scotland, United Kingdom
| | - Ruairi O’Driscoll
- School of Psychology, Faculty of Medicine and Health, University of Leeds, Leeds, England, United Kingdom
| | - António L. Palmeira
- Centro Interdisciplinar para o Estudo da Performance Humana, Faculdade de Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal
| | - Sarah E. Scott
- School of Psychology, Faculty of Medicine and Health, University of Leeds, Leeds, England, United Kingdom
| | - James Stubbs
- School of Psychology, Faculty of Medicine and Health, University of Leeds, Leeds, England, United Kingdom
| | - Berit L. Heitmann
- Research Unit for Dietary Studies, The Parker Institute, Bispebjerg and Frederiksberg Hospital, The Capital Region, København, Denmark
- The National Institute of Public Health, University of Southern Denmark, Copenhagen, Denmark
- The Boden Institute of Obesity, Nutrition, Exercise & Eating Disorders, The University of Sydney, Sydney, Australia
- Department of Public Health, Section for General Practice, University of Copenhagen, Copenhagen, Denmark
| | - Sofus C. Larsen
- Research Unit for Dietary Studies, The Parker Institute, Bispebjerg and Frederiksberg Hospital, The Capital Region, København, Denmark
| |
Collapse
|