1
|
Fang DQ, Yang DW, Mai XT, Cheung CY, Chen HY. Repeatability, interocular correlation and agreement of optic nerve head vessel density in healthy eyes: a swept-source optical coherence tomographic angiography study. Int J Ophthalmol 2024; 17:896-903. [PMID: 38766332 PMCID: PMC11074198 DOI: 10.18240/ijo.2024.05.14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Accepted: 12/12/2023] [Indexed: 05/22/2024] Open
Abstract
AIM To assess the repeatability, interocular correlation, and agreement of quantitative swept-source optical coherence tomography angiography (OCTA) optic nerve head (ONH) parameters in healthy subjects. METHODS Thirty-three healthy subjects were enrolled. The ONH of both eyes were imaged four times by a swept-source-OCTA using a 3 mm ×3 mm scanning protocol. Images of the radial peripapillary capillary were analyzed by a customized Matlab program, and the vessel density, fractal dimension, and vessel diameter index were measured. The repeatability of the four scans was determined by the intraclass correlation coefficient (ICC). The most well-centered optic disc from the four repeated scans was then selected for the interocular correlation and agreement analysis using the Pearson correlation coefficient, ICC and Bland-Altman plots. RESULTS All swept-source-OCTA ONH parameters exhibited certain repeatability, with ICC>0.760 and coefficient of variation (CoV)≤7.301%. The obvious interocular correlation was observed for papillary vessel density (ICC=0.857), vessel diameter index (ICC=0.857) and fractal dimension (ICC=0.906), while circumpapillary vessel density exhibited moderate interocular correlation (ICC=0.687). Bland-Altman plots revealed an agreement range of -5.26% to 6.21% for circumpapillary vessel density. CONCLUSION OCTA ONH parameters demonstrate good repeatability in healthy subjects. The interocular correlations of papillary vessel density, fractal dimension and vessel diameter index are high, but the correlation for circumpapillary vessel density is moderate.
Collapse
Affiliation(s)
- Dan-Qi Fang
- Joint Shantou International Eye Center, Shantou University & the Chinese University of Hong Kong, Shantou 515041, Guangdong Province, China
| | - Da-Wei Yang
- Department of Ophthalmology and Visual Sciences, Chinese University of Hong Kong, Hong Kong 999077, China
| | - Xiao-Ting Mai
- Joint Shantou International Eye Center, Shantou University & the Chinese University of Hong Kong, Shantou 515041, Guangdong Province, China
| | - Carol Y Cheung
- Department of Ophthalmology and Visual Sciences, Chinese University of Hong Kong, Hong Kong 999077, China
| | - Hao-Yu Chen
- Joint Shantou International Eye Center, Shantou University & the Chinese University of Hong Kong, Shantou 515041, Guangdong Province, China
| |
Collapse
|
2
|
Li DL, Liu MX, Yin ZJ, Li YZ, Ma R, Zheng YJ, Qin Y, Liang G, Pan CW. Refractive associations with corneal biomechanical properties among young adults: a population-based Corvis ST study. Graefes Arch Clin Exp Ophthalmol 2024; 262:121-132. [PMID: 37401934 DOI: 10.1007/s00417-023-06164-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 06/11/2023] [Accepted: 06/28/2023] [Indexed: 07/05/2023] Open
Abstract
PURPOSE To assess the associations of corneal biomechanical properties as measured by the Corvis ST with refractive errors and ocular biometry in an unselected sample of young adults. METHODS A total of 1645 healthy university students underwent corneal biomechanical parameters measurement by the Corvis ST. The refractive status of the participants was measured using an autorefractor without cycloplegia. Ocular biometric parameters were measured using the IOL Master. RESULTS After adjusting for the effect of age, sex, biomechanical-corrected intraocular pressure and central corneal thickness, axial length was significantly associated with A1 velocity (A1v, β = -10.47), A2 velocity (A2v, β = 4.66), A2 deflection amplitude (A2DeflA, β = -6.02), HC deflection amplitude (HC-DeflA, β = 5.95), HC peak distance (HC-PD, β = 2.57), deformation amplitude ratio max (DA Rmax, β = -0.36), Ambrósio's relational thickness to the horizontal profile (ARTh, β = 0.002). For axial length / corneal radius ratio, only A1v (β = -2.01), A1 deflection amplitude (A1DeflA, β = 2.30), HC-DeflA (β = 1.49), HC-PD (β = -0.21), DA Rmax (β = 0.07), stress-strain index (SSI, β = -0.29), ARTh (β < 0.001) were significant associates. A1v (β = 23.18), HC-DeflA (β = -15.36), HC-PD (β = 1.27), DA Rmax (β = -0.66), SSI (β = 3.53), ARTh (β = -0.02) were significantly associated with spherical equivalent. CONCLUSION Myopic eyes were more likely to have more deformable corneas and corneas in high myopia were easier to deform and were even softer compared with those in the mild/moderate myopia.
Collapse
Affiliation(s)
- Dan-Lin Li
- School of Public Health, Medical College of Soochow University, 199 Ren Ai Road, Suzhou, 215123, China
| | - Min-Xin Liu
- School of Public Health, Medical College of Soochow University, 199 Ren Ai Road, Suzhou, 215123, China
| | - Zhi-Jian Yin
- Department of Ophthalmology, the First Affiliated Hospital of Dali University, Dali, China
| | - Yue-Zu Li
- Department of Ophthalmology, the Affiliated Hospital of Yunnan University, 176 Qing Nian Road, Kunming, 650021, China
- Department of Ophthalmology, the Second People's Hospital of Yunnan Province, Kunming, China
| | - Rong Ma
- Department of Ophthalmology, the Affiliated Hospital of Yunnan University, 176 Qing Nian Road, Kunming, 650021, China
- Department of Ophthalmology, the Second People's Hospital of Yunnan Province, Kunming, China
| | - Ya-Jie Zheng
- Department of Ophthalmology, the Affiliated Hospital of Yunnan University, 176 Qing Nian Road, Kunming, 650021, China
- Department of Ophthalmology, the Second People's Hospital of Yunnan Province, Kunming, China
| | - Yu Qin
- Department of Ophthalmology, the Affiliated Hospital of Yunnan University, 176 Qing Nian Road, Kunming, 650021, China
- Department of Ophthalmology, the Second People's Hospital of Yunnan Province, Kunming, China
| | - Gang Liang
- Department of Ophthalmology, the Affiliated Hospital of Yunnan University, 176 Qing Nian Road, Kunming, 650021, China.
- Department of Ophthalmology, the Second People's Hospital of Yunnan Province, Kunming, China.
| | - Chen-Wei Pan
- School of Public Health, Medical College of Soochow University, 199 Ren Ai Road, Suzhou, 215123, China.
| |
Collapse
|
3
|
Ganglion Cell Complex Analysis: Correlations with Retinal Nerve Fiber Layer on Optical Coherence Tomography. Diagnostics (Basel) 2023; 13:diagnostics13020266. [PMID: 36673076 PMCID: PMC9858609 DOI: 10.3390/diagnostics13020266] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 01/08/2023] [Accepted: 01/10/2023] [Indexed: 01/12/2023] Open
Abstract
The aim of this review is to analyze the correlations between the changes in the ganglion cell complex (GCC) and the retinal nerve fiber layer (RNFL) on optical coherence tomography in different possible situations, especially in eyes with glaucoma. For glaucoma evaluation, several studies have suggested that in the early stages, GCC analysis, especially the thickness of the infero and that of the inferotemporal GCC layers, is a more sensitive examination than circumpapillary RNFL (pRNFL). In the moderate stages of glaucoma, inferior pRNFL thinning is better correlated with the disease than in advanced cases. Another strategy for glaucoma detection is to find any asymmetry of the ganglion cell-inner plexiform layers (GCIPL) between the two macular hemifields, because this finding is a valuable indicator for preperimetric glaucoma, better than the RNFL thickness or the absolute thickness parameters of GCIPL. In preperimetric and suspected glaucoma, GCC and pRNFL have better specificity and are superior to the visual field. In advanced stages, pRNFL and later, GCC reach the floor effect. Therefore, in this stage, it is more useful to evaluate the visual field for monitoring the progression of glaucoma. In conclusion, GCC and pRNFL are parameters that can be used for glaucoma diagnosis and monitoring of the progression of the disease, with each having a higher accuracy depending on the stage of the disease.
Collapse
|
4
|
Tang Y, Pan X, Cao K, Feng H, Yang Y, Hu Z, Yan F, Han Y, Li S. Ganglion Cell Complex Parameters in Primary Angle Closure Suspects. Ophthalmic Res 2021; 64:844-850. [PMID: 34139705 DOI: 10.1159/000516538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Accepted: 04/12/2021] [Indexed: 11/19/2022]
Affiliation(s)
- Yizhen Tang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
| | - Xiaohua Pan
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China,
| | - Kai Cao
- Beijing Institute of Ophthalmology, Capital Medical University, Beijing, China
| | - Hui Feng
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China
| | - Yue Yang
- Department of Ophthalmology, The Third Hospital of Mianyang, Sichuan Mental Health Center, Mianyang, China
| | - Zhongyin Hu
- Department of Ophthalmology, First People's Hospital of Yunnan Province, Kunming, China
| | - Fancheng Yan
- Department of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, Beijing, China
| | - Ying Han
- Department of Ophthalmology, University of California San Francisco, San Francisco, California, USA
| | - Shuning Li
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China
| |
Collapse
|
5
|
Han F, Li M, Wei P, Ma J, Jhanji V, Wang Y. Effect of biomechanical properties on myopia: a study of new corneal biomechanical parameters. BMC Ophthalmol 2020; 20:459. [PMID: 33213408 PMCID: PMC7678063 DOI: 10.1186/s12886-020-01729-x] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 11/11/2020] [Indexed: 12/13/2022] Open
Abstract
Background To assess the corneal stress-strain index (SSI), which is a marker for material stiffness and corneal biomechanical parameters, in myopic eyes. Methods A total of 1054 myopic patients were included in this study. Corneal visualisation Scheimpflug technology was used to measure the SSI. Corneal biomechanics were assessed using the first and second applanation times (A1-and A2-times); maximum deflection amplitude (DefAmax); deflection area (HCDefArea); the highest concavity peak distance (HC-PD), time (HC-time), and deflection amplitude (HC-DefA); integrated radius (IR); whole eye movement (WEM); stiffness parameter (SP-A1;, biomechanically corrected intraocular pressure (BIOP); and Corvis biomechanical index (CBI). Scheimpflug tomography was used to obtain the mean keratometery (Km) and central corneal thickness (CCT). According to the spherical equivalent (SE) (low myopia: SE ≥ − 3.00D and high myopia: SE ≤ − 6.00D.), the suitable patients were divided into two groups. Results The mean SSI value was 0.854 ± 0.004. The SSI had a positive correlation with A1-time ((r = 0.272), HC-time (r = 0.218), WEM (r = 0.288), SP-A1 (r = 0.316), CBI (r = 0.199), CCT (r = 0.125), bIOP (r = 0.230), and SE (r = 0.313) (all p-values<0.01). The SSI had a negative correlation with HCDefA (r = − 0.721), HCDefArea (r = − 0.665), HC-PD(r = − 0.597), IR (r = − 0.555), DefAmax (r = − 0.564), and Km (r = − 0.103) (all p-values<0.01). There were significant differences in SSI (t = 8.960, p<0.01) and IR (t = − 3.509, p<0.01) between the low and high myopia groups. Conclusions In different grades of myopia, the SSI values were lower in eyes with higher SEs. It indicates that the mechanical strength of the cornea may be compromised in high myopia. The SSI was positively correlated with the spherical equivalent, and it may provide a new way to study the mechanism of myopia.
Collapse
Affiliation(s)
- Fang Han
- Clinical College of Ophthalmology, Tianjin Medical University, No.4, Gansu Road, Heping District, Tianjin, 300020, China.,Department of Ophthalmology, The 1st People's Hospital of Yunnan Province, Jinbi Rd 157#, Kunming, 650031, China.,Department of Ophthalmology, The Affiliated Hospital of Kunming Science and Technology University, Jinbi Rd 157#, Kunming, 650031, China
| | - Mengdi Li
- Clinical College of Ophthalmology, Tianjin Medical University, No.4, Gansu Road, Heping District, Tianjin, 300020, China
| | - Pinghui Wei
- Clinical College of Ophthalmology, Tianjin Medical University, No.4, Gansu Road, Heping District, Tianjin, 300020, China.,Tianjin Eye Hospital, Tianjin Eye Institute, Tianjin Key Laboratory of Ophthalmology and Visual Science, Nankai University Affiliated Eye Hospital, Tianjin, China
| | - Jiaonan Ma
- Clinical College of Ophthalmology, Tianjin Medical University, No.4, Gansu Road, Heping District, Tianjin, 300020, China
| | - Vishal Jhanji
- UPMC Eye Center, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA
| | - Yan Wang
- Clinical College of Ophthalmology, Tianjin Medical University, No.4, Gansu Road, Heping District, Tianjin, 300020, China. .,Tianjin Eye Hospital, Tianjin Eye Institute, Tianjin Key Laboratory of Ophthalmology and Visual Science, Nankai University Affiliated Eye Hospital, Tianjin, China.
| |
Collapse
|