1
|
Wu THY, Lau HKC, Lai CHY, Wong RWL, Wong AKW, Lam AKC. Effect of digital ocular massage on intraocular pressure and Schlemm's canal dimensions. Sci Rep 2024; 14:6112. [PMID: 38480777 PMCID: PMC10937985 DOI: 10.1038/s41598-024-56748-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Accepted: 03/11/2024] [Indexed: 03/17/2024] Open
Abstract
Digital ocular massage has been reported to temporarily lower intraocular pressure (IOP). This could be related to an enhanced aqueous humor outflow; however, the mechanism is not clearly understood. Using anterior segment optical coherence tomography, the Schlemm's canal (SC) and trabecular meshwork (TM) can be imaged and measured. Here, 66 healthy adults underwent digital ocular massage for 10 min in their right eyes. The IOP and dimensions of the SC and TM were measured before and after ocular massage. All subjects demonstrated IOP reduction from 15.7 ± 2.5 mmHg at baseline to 9.6 ± 2.2 mmHg immediately after, and median of 11.6 mmHg 5-min after ocular massage (Friedman's test, p < 0.001). There was significant change in SC area (median 10,063.5 μm2 at baseline to median 10,151.0 μm2 after ocular massage, Wilcoxon test, p = 0.02), and TM thickness (median 149.8 μm at baseline to 144.6 ± 25.3 μm after ocular massage, Wilcoxon test, p = 0.036). One-third of the subjects demonstrated collapse of the SC area (-2 to -52%), while two-thirds showed expansion of the SC area (2 to 168%). There were no significant changes in SC diameter (270.4 ± 84.1 μm vs. 276.5 ± 68.7 μm, paired t-test, p = 0.499), and TM width (733.3 ± 110.1 μm vs. 733.5 ± 111.6 μm, paired t-test, p = 0.988). Eyes with a higher baseline IOP demonstrated a greater IOP reduction (Pearson correlation coefficient r = -0.521, p < 0.001). Eyes with smaller SC area at baseline showed greater SC area expansion (Pearson correlation coefficient = -0.389, p < 0.001). Greater IOP reduction appeared in eyes with greater SC area expansion (Pearson correlation coefficient r = -0.306, p = 0.01). Association between change in IOP and change in TM thickness was not significant (Spearman's ρ = 0.015, p = 0.902). Simple digital ocular massage is an effective method to lower IOP values, and change in the SC area was significantly associated with IOP changes.
Collapse
Affiliation(s)
- Tiffany H Y Wu
- School of Optometry, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
| | - Henry K C Lau
- School of Optometry, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
| | - Carmelo H Y Lai
- School of Optometry, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
| | - Ruby W L Wong
- School of Optometry, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
| | - Antonia K W Wong
- School of Optometry, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
| | - Andrew Kwok-Cheung Lam
- School of Optometry, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong.
- Research Centre for SHARP Vision, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong.
- Centre for Eye and Vision Research, 17W Hong Kong Science Park, Science Park, Hong Kong.
| |
Collapse
|
2
|
Mirzayev I, Gündüz AK, Aydın Ellialtıoğlu P, Gündüz ÖÖ. Clinical applications of anterior segment swept-source optical coherence tomography: A systematic review. Photodiagnosis Photodyn Ther 2023; 42:103334. [PMID: 36764640 DOI: 10.1016/j.pdpdt.2023.103334] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 01/25/2023] [Accepted: 02/07/2023] [Indexed: 02/11/2023]
Abstract
Optical coherence tomography (OCT) is a non-invasive method that provides the opportunity to examine tissues by taking cross-sectional images. OCT is increasingly being used to evaluate anterior segment (AS) pathologies. Swept-source (SS) OCT allows greater penetration and achieves better visualization of the internal configuration of AS tissues due to the longer wavelength employed and high scan speeds. We reviewed the utilization of AS SS-OCT in various conditions including glaucoma, ocular surface pathologies, iris tumors, refractive surgery, cataract surgery, and scleral diseases. A systematic literature search was carried out on PubMed, Scopus, and Web of Science databases between January 1, 2008, and September 1, 2022 using the following keywords: AS SS-OCT; dry eye and SS-OCT; ocular surface and SS-OCT; cornea and SS-OCT; dystrophy and SS-OCT; glaucoma and SS-OCT; ocular surface tumors and SS-OCT; conjunctival tumors and SS-OCT; refractive surgery and SS-OCT; cataract and SS-OCT; biometry and SS-OCT; sclera and SS-OCT; iris and SS-OCT; ciliary body and SS-OCT; artificial intelligence and SS-OCT. A total of 221 studies were included in this review. Review of the existing literature shows that SS-OCT offers several advantages in the diagnosis of AS diseases. Exclusive features of SS-OCT including rapid scanning, deeper tissue penetration, and better image quality help improve our understanding of various AS pathologies.
Collapse
Affiliation(s)
- Ibadulla Mirzayev
- Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey; Halil Şıvgın Çubuk State Hospital, Ophthalmology Clinic, Ankara, Turkey
| | - Ahmet Kaan Gündüz
- Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey; Private Eye Clinic, Ankara, Turkey.
| | | | - Ömür Özlenen Gündüz
- Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey
| |
Collapse
|
3
|
Li Z, Meng Z, Qu W, Li X, Chang P, Wang D, Zhao Y. The Relationship Between Age and the Morphology of the Crystalline Lens, Ciliary Muscle, Trabecular Meshwork, and Schlemm's Canal: An in vivo Swept-Source Optical Coherence Tomography Study. Front Physiol 2021; 12:763736. [PMID: 34867468 PMCID: PMC8640208 DOI: 10.3389/fphys.2021.763736] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Accepted: 10/29/2021] [Indexed: 01/07/2023] Open
Abstract
Purpose: To evaluate the effects of age on the morphologies of the crystalline lens, ciliary muscle (CM), Schlemm’s canal (SC), and trabecular meshwork (TM) using swept-source optical coherence tomography (SS-OCT). Methods: Images of the crystalline lens and iridocorneal angle were obtained in healthy participants’ eyes using SS-OCT. Morphological parameters of the crystalline lens, CM, and TM/SC were measured, and the relationship between these parameters and age was evaluated. Results: A total of 62 healthy participants were enrolled, with an age range of 7–79 years. With adjustments for the effects of axial length and sex, both the nasal and temporal SC cross-sectional areas (CSA) and the cross-sectional area of the CM (CMA), distance from the scleral spur to the inner apex of the ciliary muscle (IA-SS), and nasal SC volume were negatively correlated with age (P ≤ 0.041). Meanwhile, the lens thickness (LT) (P < 0.001) and lens vault (LV) (P < 0.001) were positively correlated with age, and the radius of the curvature of the anterior lens (ALR) was negatively correlated with age (P < 0.001). Conclusion: Increasing age was associated with a thicker crystalline lens, a steeper anterior lens curvature, an anteriorly located and smaller CM, and a narrower SC. Clinical Trial Registration:https://register.clinicaltrials.gov/prs/app/action/Select Protocol?sid=S000A3JZ&selectaction=Edit&uid=U00019K7&ts=4&cx=-c5xxp8, identifier [NCT04576884].
Collapse
Affiliation(s)
- Zhangliang Li
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China.,National Clinical Research Center for Ocular Diseases, Wenzhou, China.,Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, China
| | - Ziqi Meng
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China.,National Clinical Research Center for Ocular Diseases, Wenzhou, China.,Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, China
| | - Wenyong Qu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China.,National Clinical Research Center for Ocular Diseases, Wenzhou, China.,Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, China
| | - Xiuyuan Li
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China.,National Clinical Research Center for Ocular Diseases, Wenzhou, China.,Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, China
| | - Pingjun Chang
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China.,National Clinical Research Center for Ocular Diseases, Wenzhou, China.,Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, China
| | - Dandan Wang
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China.,National Clinical Research Center for Ocular Diseases, Wenzhou, China.,Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, China
| | - Yune Zhao
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China.,National Clinical Research Center for Ocular Diseases, Wenzhou, China.,Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, China
| |
Collapse
|
4
|
Chen L, Jin W, Hao X, Li X, Xing Y. Dynamic changes of scleral spur length in different accommodation stimuli states. Sci Rep 2021; 11:18176. [PMID: 34518627 PMCID: PMC8438021 DOI: 10.1038/s41598-021-97754-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Accepted: 08/30/2021] [Indexed: 11/09/2022] Open
Abstract
This study aimed to evaluate the scleral spur length (SSL) in response to different accommodation stimuli states, as well as the correlation with Schlemm’s canal (SC) and trabecular meshwork (TM). 74 children were recruited for this study. The 0D, − 4D, and − 8.0 D accommodation stimuli state was achieved by looking at a variable distance optotype. The ciliary muscle (CM), scleral spur (SS), SC, and TM were imaged by swept-source optical coherence tomography. The SSL (Method III) increased significantly from 221.56 ± 30.74 μm at base state to 234.99 ± 30.11 μm at − 4D accommodation stimuli state (p = 0.028) and increased to 250.09 ± 29.87 μm at − 8D accommodation stimuli state (p = 0.011). Method III had the largest areas under receiver operating characteristic (ROC) curves (0.798, 95% CI 0.721–0.875). Moreover, CM 1, SC, and trabecular meshwork length (TML) were significantly correlated with SSL (Method III) (p < 0.05). These findings suggest that the contractile ability and compliance of the SS play an important role in maintaining the morphology of the SC. Moreover, the force of accommodation regulates the SC size by increasing the length of SS.
Collapse
Affiliation(s)
- Liugui Chen
- Eye Center, Renmin Hospital of Wuhan University, Jiefang Road 238#, Wuchang District, Wuhan, 430060, Hubei Province, China
| | - Wei Jin
- Eye Center, Renmin Hospital of Wuhan University, Jiefang Road 238#, Wuchang District, Wuhan, 430060, Hubei Province, China
| | - Xinlei Hao
- Eye Center, Renmin Hospital of Wuhan University, Jiefang Road 238#, Wuchang District, Wuhan, 430060, Hubei Province, China
| | - Xuejie Li
- Eye Center, Renmin Hospital of Wuhan University, Jiefang Road 238#, Wuchang District, Wuhan, 430060, Hubei Province, China
| | - Yiqiao Xing
- Eye Center, Renmin Hospital of Wuhan University, Jiefang Road 238#, Wuchang District, Wuhan, 430060, Hubei Province, China.
| |
Collapse
|
5
|
Quantitative analysis of internal components of the human crystalline lens during accommodation in adults. Sci Rep 2021; 11:6688. [PMID: 33758264 PMCID: PMC7987977 DOI: 10.1038/s41598-021-86007-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Accepted: 03/08/2021] [Indexed: 12/23/2022] Open
Abstract
To quantitatively analyze changes in the inner components of the human crystalline lens during accommodation in adults. Eyes of 23 subjects were sequentially examined using CASIA2 Optical Coherence Tomography under 0D, - 3D and - 6D accommodation states. The anterior chamber depth (ACD), anterior and posterior crystalline lens radius of the curvature (ALRC and PLRC) were obtained using built-in software. The lens thickness (LT), lenticular nucleus thickness (NT), anterior cortex thickness (ACT), posterior cortex thickness (PCT), anterior and posterior lenticular nucleus radius of the curvature (ANRC and PNRC), anterior and posterior lenticular nucleus vertex (ANV and PNV) were quantified manually with the Image-pro plus software. During accommodation, the ACD became significantly shallower and LT significantly increased. For changes in the lens, the ALRC decreased by an average magnitude (related to accommodative stimuli) 0.44 mm/D, and PLRC decreased 0.09 mm/D. There was no difference for the ACT and PCT in different accommodation states. For lenticular nucleus response, NT increased on average by 30 μm/D. Both the ANRC and PNRC decreased on average by 212 μm/D and 115 μm/D respectively. The ANV moved forward on average by 0.07 mm under - 3D accommodative stimuli and 0.16 mm for - 6D. However, there was no statistically significant difference between different accommodation states in the PNV movement. Under accommodation stimulation, lens thickness changed mainly due to the lenticular nucleus, but not the cortex. For the lenticular nucleus, both the ANRC and PNRC decreased and ANRC changed the most. The anterior surface of the nucleus moved forward while the posterior surface of the nucleus moved backward but only slightly.
Collapse
|
6
|
Accommodative Exercises to Lower Intraocular Pressure. J Ophthalmol 2020; 2020:6613066. [PMID: 33489336 PMCID: PMC7803153 DOI: 10.1155/2020/6613066] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 12/09/2020] [Indexed: 02/02/2023] Open
Abstract
Purpose This study investigated how a conscious change in ocular accommodation affects intraocular pressure (IOP) and ocular biometrics in healthy adult volunteers of different ages. Methods Thirty-five healthy volunteers without ocular disease or past ocular surgery, and with refractive error between −3.50 and +2.50 diopters, were stratified into 20, 40, and 60 year old (y.o.) age groups. Baseline measurements of central cornea thickness, anterior chamber depth, anterior chamber angle, cornea diameter, pupil size, and ciliary muscle thickness were made by autorefraction and optical coherence tomography (OCT), while IOP was measured by pneumotonometry. Each subject's right eye focused on a target 40 cm away. Three different tests were performed in random order: (1) 10 minutes of nonaccommodation (gazing at the target through lenses that allowed clear vision without accommodating), (2) 10 minutes of accommodation (addition of a minus 3 diopter lens), and (3) 10 minutes of alternating between accommodation and nonaccommodation (1-minute intervals). IOP was measured immediately after each test. A 20-minute rest period was provided between tests. Data from 31 subjects were included in the study. ANOVA and paired t-tests were used for statistical analyses. Results Following alternating accommodation, IOP decreased by 0.7 mmHg in the right eye when all age groups were combined (p = 0.029). Accommodation or nonaccommodation alone did not decrease IOP. Compared to the 20 y.o. group, the 60 y.o. group had a thicker ciliary muscle within 75 μm of the scleral spur, a thinner ciliary muscle at 125–300 μm from the scleral spur, narrower anterior chamber angles, shallower anterior chambers, and smaller pupils during accommodation and nonaccommodation (p's < 0.01). Conclusion Alternating accommodation, but not constant accommodation, significantly decreased IOP. This effect was not lost with aging despite physical changes to the aging eye. A greater accommodative workload and/or longer test period may improve the effect.
Collapse
|
7
|
Dahlmann-Noor AH. Comment on: "Measuring changes in Schlemm's canal and trabecular meshwork in different accommodation states in myopia children: an observational study". Eye (Lond) 2020; 35:1794. [PMID: 32694600 DOI: 10.1038/s41433-020-1099-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Revised: 07/09/2020] [Accepted: 07/09/2020] [Indexed: 11/09/2022] Open
Affiliation(s)
- Annegret H Dahlmann-Noor
- National Institute of Health Research Moorfields Biomedical Research Centre, 162 City Road, London, EC1V 2PD, UK. .,Paediatric Service, Moorfields Eye Hospital NHS Foundation Trust, 162 City Road, London, EC1V 2PD, UK.
| |
Collapse
|
8
|
Response to 'Comment on: "Measuring changes in Schlemm's canal and trabecular meshwork in different accommodation states in myopia children: an observational study"'. Eye (Lond) 2020; 35:1785-1786. [PMID: 32690921 DOI: 10.1038/s41433-020-1097-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 06/05/2020] [Accepted: 07/09/2020] [Indexed: 11/08/2022] Open
|