Yang X, Jiang Y, Lin S, Bai X, Yin Y, Zhao F, Yang J, Tian F, Chen X, Liang J, Bu S. The predictive accuracy of Barrett toric calculator using measured posterior corneal astigmatism derived from swept source-OCT and Scheimpflug camera. Eye (Lond) 2024; 38:132-137. [PMID: 37380787 PMCID: PMC10764741 DOI: 10.1038/s41433-023-02646-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 06/01/2023] [Accepted: 06/16/2023] [Indexed: 06/30/2023] Open
Abstract
PURPOSE To compare the performance of Barrett toric calculator incorporated with measured posterior corneal astigmatism (PCA) derived from IOL Master 700 and Pentacam HR versus predicted PCA. METHODS The predicted residual astigmatism using Barrett toric IOL calculator with predicted PCA, measured PCA from IOL Master 700 and measured PCA from Pentacam were calculated with the preoperative keratometry and intended IOL axis with modification. The vector analysis was performed to calculate the mean absolute prediction error (MAE), the centroid of the prediction error and the percentage of eyes with a prediction error within ±0.50 D, ±0.75 D, and ±1.00 D. RESULTS In 57 eyes of 57 patients with mean age of 70.42 ± 10.75 years, the MAE among the three calculation methods were 0.59 ± 0.38 D (Predicted PCA), 0.60 ± 0.38 D (Measured PCA from IOL Master 700) and 0.60 ± 0.36 D (Measured PCA from Pentacam) with no significant difference, either in the whole sample, the WTR eyes and the ATR eyes (F = 0.078, 0.306 and 0.083, p = 0.925, 0.739 and 0.920, respectively). Measured PCA obtained from IOL Master 700 resulted in one level reduction (from Tn to Tn-1) in 49.12% eyes in cylindrical model selection, while measured PCA obtained from Pentacam resulted in one level reduction of toric model selection in 18.18% eyes. CONCLUSION The present study suggested that the incorporation of measured PCA values derived from IOL Master 700 and Pentacam produce comparable clinical outcome with the predicted PCA mode in Barrett toric calculator.
Collapse
Affiliation(s)
- Xiaotong Yang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Yuanfeng Jiang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Song Lin
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Xiaomei Bai
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Yufan Yin
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - FangYu Zhao
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Jun Yang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Fang Tian
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Xiteng Chen
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Jingli Liang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Shaochong Bu
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China.
| |
Collapse
|
2
|
Langenbucher A, Schrecker J, Schwemm M, Eppig T, Schröder S, Szentmáry N. [Monte Carlo simulation of biometric effect sizes and their influence on the translational ratio of corneal astigmatism in the cylinders of toric intraocular lenses]. Ophthalmologe 2021; 118:569-577. [PMID: 32767100 PMCID: PMC8187219 DOI: 10.1007/s00347-020-01199-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Hintergrund und Zielsetzung Torische Kapselsacklinsen bieten heutzutage eine zuverlässige Option der permanenten Korrektur eines Hornhautastigmatismus. Zur Ermittlung der für den gewünschten Ausgleich erforderlichen Linsenstärke kann der Operateur entweder auf die in seinem Biometriegerät implementierten Berechnungsmodi oder auf den vom Linsenhersteller angebotenen Kalkulationsservice zurückgreifen. In vielen Fällen wird dabei allerdings keine klassische Linsenberechnung aus biometrischen Daten durchgeführt, sondern nur mit einer vereinfachten Abschätzung gearbeitet, die den Hornhautastigmatismus in den Torus der tIOL übersetzt. Dieses dann zumeist als durchschnittlicher Standardwert genutzte Übersetzungsverhältnis kann jedoch eine erhebliche Schwankungsbreite aufweisen, sodass im ungünstigsten Fall eine Unterkorrektur des refraktiven Zylinders um bis zu 12,5 % oder eine Überkorrektur um bis zu 17 % resultieren kann. Ziel dieser Studie war es aufzuzeigen, welche biometrischen Einflussgrößen das Verhältnis zwischen dem zu korrigierenden Hornhautastigmatismus und dem für dessen Vollkorrektur notwendigen Torus einer Kapselsacklinse bestimmen. Methoden Aus der WEB-Plattform IOLCon wurden 16.744 Datensätze extrahiert, und anhand der präoperativen biometrischen Größen und dem postoperativen sphärischen Äquivalent wurde zunächst die axiale Position der Kapselsacklinse formelunabhängig abgeleitet. Anschließend wurde, basierend auf der Propagation sphärozylindrischer Vergenzen, der entsprechende Brechwert einer emmetropisierenden Kapselsacklinse ermittelt. Das Übersetzungsverhältnis als Quotient aus dem Torus der Linse und dem Hornhautastigmatismus wurde mit einer Monte-Carlo-Simulation auf seine potenziellen Einflussgrößen hin untersucht. Ergebnisse Die Monte-Carlo-Simulation zeigt, dass nicht von einem konstanten Übersetzungsverhältnis ausgegangen werden kann. Für die hier zugrunde gelegten klinischen Fälle ergibt sich ein mittleres Übersetzungsverhältnis von 1,3938 ± 0,0595 (Median 1,3921) mit einer Spannweite von 1,2131 bis 1,5974. Den größten Einfluss hat hierbei die axiale Position der Kapselsacklinse – je weiter posterior sich diese befindet, desto höher ist das Übersetzungsverhältnis. Aufgrund der Korrelation der axialen Linsenposition mit der Augenlänge kann die Augenlänge als indirekte Einflussgröße gewertet werden. Der Äquivalentbrechwert sowie der Astigmatismus der Hornhaut besitzen keinen nennenswerten Effekt auf das Übersetzungsverhältnis. Diskussion In einer ganzen Reihe von Berechnungsmodulen wird die Kalkulation des Torus der Kapselsacklinse dahingehend vereinfacht, dass dieser mittels eines einfachen konstanten Umrechnungsfaktors aus dem gemessenen Hornhautastigmatismus abgeleitet wird. Die vorliegende Studie zeigt jedoch, dass diese Vereinfachung zu deutlich fehlerhaften Ergebnissen führen kann. Dementsprechend wird eine individuelle Berechnung des Torus der IOL aus gemessenen biometrischen Größen (z. B. mittels Vergenzpropagation, Matrizen oder mittels Full-aperture-Raytracing) empfohlen.
Collapse
Affiliation(s)
- Achim Langenbucher
- Institut für Experimentelle Ophthalmologie, Universität des Saarlandes, Kirrberger Str. 100, Gebäude 22, 66424, Homburg, Deutschland.
| | - Jens Schrecker
- Klinik für Augenheilkunde, Rudolf-Virchow-Klinikum, Glauchau, Deutschland
| | - Michael Schwemm
- Institut für Experimentelle Ophthalmologie, Universität des Saarlandes, Kirrberger Str. 100, Gebäude 22, 66424, Homburg, Deutschland
| | - Timo Eppig
- Institut für Experimentelle Ophthalmologie, Universität des Saarlandes, Kirrberger Str. 100, Gebäude 22, 66424, Homburg, Deutschland
| | - S Schröder
- Institut für Experimentelle Ophthalmologie, Universität des Saarlandes, Kirrberger Str. 100, Gebäude 22, 66424, Homburg, Deutschland
| | - Nóra Szentmáry
- Dr. Rolf M. Schwiete Zentrum für Limbusstammzellforschung und kongenitale Aniridie, Universität des Saarlandes, Kirrberger Str., Gebäude 22, 66421, Homburg, Deutschland.,Klinik für Augenheilkunde, Semmelweis-Universität, Mária u. 39, 1085, Budapest, Ungarn
| |
Collapse
|