Moon W, Feng X, Li GY, Yun SH. High-Frequency Optical Coherence Elastography for Gingival Tissue Characterization: Variability in Stiffness and Response to Physiological Conditions. Biomater Res 2024; 28:0044. [PMID: 38952715 PMCID: PMC11214824 DOI: 10.34133/bmr.0044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2024] [Accepted: 05/08/2024] [Indexed: 07/03/2024] Open
Abstract
Accurate measurement of gingiva's biomechanical properties in vivo has been an active field of research but remained an unmet challenge. Currently, there are no noninvasive tools that can accurately quantify tensile and shear moduli, which govern gingival health, with sufficiently high accuracy. This study presents the application of high-frequency optical coherence elastography (OCE) for characterizing gingival tissue in both porcine models and human subjects. Dynamic mechanical analysis, histology studies, and strain analysis are performed to support the OCE result. Our findings demonstrate substantial differences in tissue stiffness between supra-dental and inter-dental gingiva, validated by dynamic mechanical analysis and OCE. We confirmed the viscoelastic, nearly linear, and transverse-isotropic properties of gingiva in situ, establishing the reliability of OCE measurements. Further, we investigated the effects of tissue hydration, collagen degradation, and dehydration on gingival stiffness. These conditions showed a decrease and increase in stiffness, respectively. While preliminary, our study suggests OCE's potential in periodontal diagnosis and oral tissue engineering, offering real-time, millimeter-scale resolution assessments of tissue stiffness, crucial for clinical applications and biomaterial optimization in reconstructive surgeries.
Collapse
Affiliation(s)
- Wonjoon Moon
- Harvard Medical School and Wellman Center for Photomedicine,
Massachusetts General Hospital, Boston, MA 02114, USA
| | - Xu Feng
- Harvard Medical School and Wellman Center for Photomedicine,
Massachusetts General Hospital, Boston, MA 02114, USA
| | - Guo-Yang Li
- Harvard Medical School and Wellman Center for Photomedicine,
Massachusetts General Hospital, Boston, MA 02114, USA
| | - Seok-Hyun Yun
- Harvard Medical School and Wellman Center for Photomedicine,
Massachusetts General Hospital, Boston, MA 02114, USA
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA 02139, USA
| |
Collapse
|
2
|
Li GY, Feng X, Yun SH. In Vivo Optical Coherence Elastography Unveils Spatial Variation of Human Corneal Stiffness. IEEE Trans Biomed Eng 2024; 71:1418-1429. [PMID: 38032780 PMCID: PMC11086014 DOI: 10.1109/tbme.2023.3338086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2023]
Abstract
OBJECTIVE The mechanical properties of corneal tissues play a crucial role in determining corneal shape and have significant implications in vision care. This study aimed to address the challenge of obtaining accurate in vivo data for the human cornea. METHODS We have developed a high-frequency optical coherence elastography (OCE) technique using shear-like antisymmetric (A0)-mode Lamb waves at frequencies above 10 kHz. RESULTS By incorporating an anisotropic, nonlinear constitutive model and utilizing the acoustoelastic theory, we gained quantitative insights into the influence of corneal tension on wave speeds and elastic moduli. Our study revealed significant spatial variations in the shear modulus of the corneal stroma on healthy subjects for the first time. Over an age span from 21 to 34 (N = 6), the central corneas exhibited a mean shear modulus of 87 kPa, while the corneal periphery showed a significant decrease to 44 kPa. The central cornea's shear modulus decreases with age with a slope of -19 +/- 8 kPa per decade, whereas the periphery showed non-significant age dependence. The limbus demonstrated an increased shear modulus exceeding 100 kPa. We obtained wave displacement profiles that are consistent with highly anisotropic corneal tissues. CONCLUSION Our approach enabled precise measurement of corneal tissue elastic moduli in situ with high precision (<7%) and high spatial resolution (<1 mm). Our results revealed significant stiffness variation from the central to peripheral corneas. SIGNIFICANCE The high-frequency OCE technique holds promise for biomechanical evaluation in clinical settings, providing valuable information for refractive surgeries, degenerative disorder diagnoses, and intraocular pressure assessments.
Collapse
|
3
|
Song C, He W, Feng J, Twa MD, Huang Y, Xu J, Qin J, An L, Wei X, Lan G. Dual-channel air-pulse optical coherence elastography for frequency-response analysis. BIOMEDICAL OPTICS EXPRESS 2024; 15:3301-3316. [PMID: 38855682 PMCID: PMC11161337 DOI: 10.1364/boe.520551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 04/09/2024] [Accepted: 04/16/2024] [Indexed: 06/11/2024]
Abstract
Microliter air-pulse optical coherence elastography (OCE) has recently been proposed for the characterization of soft-tissue biomechanics using transient, sub-nanometer to micrometer-scale natural frequency oscillations. However, previous studies have not been able to provide real-time air-pulse monitoring during OCE natural frequency measurement, which could lead to inaccurate measurement results due to the unknown excitation spectrum. To address this issue, we introduce a dual-channel air-pulse OCE method, with one channel stimulating the sample and the other being simultaneously measured with a pressure sensor. This allows for more accurate natural frequency characterization using the frequency response function, as proven by a comprehensive comparison under different conditions with a diverse range of excitation spectra (from broad to narrow, clean to noisy) as well as a diverse set of sample response spectra. We also demonstrate the capability of the frequency-response analysis in distinguishing samples with different stiffness levels: the dominant natural frequencies increased with agar concentrations (181-359 Hz, concentrations: 1-2%, and maximum displacements: 0.12-0.47 µm) and intraocular pressures (IOPs) for the silicone cornea (333-412 Hz, IOP: 5-40 mmHg, and maximum displacements: 0.41-0.52 µm) under a 200 Pa stimulation pressure. These frequencies remained consistent across different air-pulse durations (3 ms to 35 ms). The dual-channel OCE approach that uses transient, low-pressure stimulation and high-resolution imaging holds the potential to advance our understanding of sample frequency responses, especially when investigating delicate tissues such as the human cornea in vivo.
Collapse
Affiliation(s)
- Chengjin Song
- Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China
| | - Weichao He
- Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China
| | - Jinping Feng
- Institute of Engineering and Technology, Hubei University of Science and Technology, Xianning, Hubei 437100, China
| | - Michael D. Twa
- College of Optometry, University of Houston, Houston, TX 77204, USA
| | - Yanping Huang
- Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China
- Guangdong Weiren Meditech Co., Ltd., Foshan, Guangdong 528000, China
| | - Jingjiang Xu
- Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China
- Guangdong Weiren Meditech Co., Ltd., Foshan, Guangdong 528000, China
| | - Jia Qin
- Guangdong Weiren Meditech Co., Ltd., Foshan, Guangdong 528000, China
| | - Lin An
- Guangdong Weiren Meditech Co., Ltd., Foshan, Guangdong 528000, China
| | - Xunbin Wei
- Cancer Hospital and Institute, Key Laboratory of Carcinogenesis and Translational Research, Peking University, Beijing 100142, China
- Biomedical Engineering Department, Peking University, Beijing 100081, China
- Institute of Medical Technology, Peking University Health Science Center, Beijing 100191, China
- International Cancer Institute, Peking University, Beijing 100191, China
| | - Gongpu Lan
- Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China
- Guangdong Weiren Meditech Co., Ltd., Foshan, Guangdong 528000, China
| |
Collapse
|
4
|
Li GY, Feng X, Yun SH. Simultaneous tensile and shear measurement of the human cornea in vivo using S0- and A0-wave optical coherence elastography. Acta Biomater 2024; 175:114-122. [PMID: 38101555 PMCID: PMC10872441 DOI: 10.1016/j.actbio.2023.12.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 11/09/2023] [Accepted: 12/08/2023] [Indexed: 12/17/2023]
Abstract
Understanding corneal stiffness is valuable for improving refractive surgery, detecting corneal abnormalities, and assessing intraocular pressure. However, accurately measuring the elastic properties, specifically the tensile and shear moduli that govern mechanical deformation, has been challenging. To tackle this issue, we have developed guided-wave optical coherence elastography that can simultaneously excite and analyze symmetric (S0) and anti-symmetric (A0) elastic waves in the cornea at around 10 kHz frequencies, enabling us to extract tensile and shear properties from measured wave dispersion curves. We verified the technique using elastomer phantoms and ex vivo porcine corneas and investigated the dependence on intraocular pressure using acoustoelastic theory that incorporates corneal tension and a nonlinear constitutive tissue model. In a pilot study involving six healthy human subjects aged 31 to 62, we measured shear moduli (Gzx) of 94±20 kPa (mean±standard deviation) and tensile moduli (Exx) of 4.0±1.1 MPa at central corneas. Our preliminary analysis of age-dependence revealed contrasting trends: -8.3±4.5 kPa/decade for shear and 0.30±0.21 MPa/decade for tensile modulus. This OCE technique has the potential to become a highly useful clinical tool for the quantitative biomechanical assessment of the cornea. STATEMENT OF SIGNIFICANCE: This article reports an innovative elastography technique using two guided elastic waves, demonstrating the measurement of both tensile and shear moduli in human cornea in vivo with unprecedented precision. This technique paves the way for comprehensive investigations into corneal mechanics and holds clinical significance in various aspects of corneal health and disease management.
Collapse
Affiliation(s)
- Guo-Yang Li
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, 50 Blossom St., Boston, MA 02114, USA
| | - Xu Feng
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, 50 Blossom St., Boston, MA 02114, USA
| | - Seok-Hyun Yun
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, 50 Blossom St., Boston, MA 02114, USA; Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA 02139, USA.
| |
Collapse
|
5
|
Li GY, Feng X, Yun SH. Simultaneous tensile and shear measurement of the human cornea in vivo using S0- and A0-wave optical coherence elastography. ARXIV 2023:arXiv:2308.05316v1. [PMID: 37608935 PMCID: PMC10441437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Figures] [Subscribe] [Scholar Register] [Indexed: 08/24/2023]
Abstract
Understanding corneal stiffness is valuable for improving refractive surgery, detecting corneal abnormalities, and assessing intraocular pressure. However, accurately measuring the elastic properties, particularly the tensile and shear moduli that govern mechanical deformation, has been challenging. To tackle this issue, we have developed guided-wave optical coherence elastography that can simultaneously excite and analyze symmetric (S0) and anti-symmetric (A0) elastic waves in the cornea at frequencies around 10 kHz and allows us to extract tensile and shear properties from measured wave dispersion curves. By applying acoustoelastic theory that incorporates corneal tension and a nonlinear constitutive tissue model, we verified the technique using elastomer phantoms and ex vivo porcine corneas and investigated the dependence on intraocular pressure. For two healthy human subjects, we measured a mean tensile modulus of 3.6 MPa and a mean shear modulus of 76 kPa in vivo with estimated errors of < 4%. This technique shows promise for the quantitative biomechanical assessment of the cornea in a clinical setting.
Collapse
Affiliation(s)
- Guo-Yang Li
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, 50 Blossom St., Boston, MA 02114, USA
| | - Xu Feng
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, 50 Blossom St., Boston, MA 02114, USA
| | - Seok-Hyun Yun
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, 50 Blossom St., Boston, MA 02114, USA
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA 02139, USA
| |
Collapse
|