1
|
Feng Y, Yan H, Mou X, Yang Z, Qiao C, Jia Q, Zhang R, Wang Z. A Dual-Cascade Activatable Near-Infrared Fluorescent Probe for Precise Intraoperative Imaging of Tumor. NANO LETTERS 2024; 24:6131-6138. [PMID: 38727077 DOI: 10.1021/acs.nanolett.4c01364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2024]
Abstract
Accurate intraoperative tumor delineation is critical to achieving successful surgical outcomes. However, conventional techniques typically suffer from poor specificity and low sensitivity and are time-consuming, which greatly affects intraoperative decision-making. Here, we report a cascade activatable near-infrared fluorescent (NIRF) probe IR780SS@CaP that can sequentially respond to tumor acidity and elevated glutathione levels for accurate intraoperative tumor localization. Compared with nonactivatable and single-factor activatable probes, IR780SS@CaP with a cascade strategy can minimize nonspecific activation and false positive signals in a complicated biological environment, affording a superior tumor-to-normal tissue ratio to facilitate the delineation of abdominal metastases. Small metastatic lesions that were less than 1 mm in diameter can be precisely identified by IR780SS@CaP and completely excised under NIRF imaging guidance. This study could benefit tumor diagnosis and image-guided tumor surgery by providing real-time information and reliable decision support, thus reducing the risk of both recurrence and complications to improve patient outcomes.
Collapse
Affiliation(s)
- Yanbin Feng
- Lab of Molecular Imaging and Translational Medicine (MITM), Engineering Research Center of Molecular and Neuro Imaging, Ministry of Education, School of Life Science and Technology, Xidian University & International Joint Research Center for Advanced Medical Imaging and Intelligent Diagnosis and Treatment, Xi'an, Shaanxi 710126, China
| | - Haohao Yan
- Lab of Molecular Imaging and Translational Medicine (MITM), Engineering Research Center of Molecular and Neuro Imaging, Ministry of Education, School of Life Science and Technology, Xidian University & International Joint Research Center for Advanced Medical Imaging and Intelligent Diagnosis and Treatment, Xi'an, Shaanxi 710126, China
| | - Xiaocheng Mou
- Lab of Molecular Imaging and Translational Medicine (MITM), Engineering Research Center of Molecular and Neuro Imaging, Ministry of Education, School of Life Science and Technology, Xidian University & International Joint Research Center for Advanced Medical Imaging and Intelligent Diagnosis and Treatment, Xi'an, Shaanxi 710126, China
| | - Zuo Yang
- Lab of Molecular Imaging and Translational Medicine (MITM), Engineering Research Center of Molecular and Neuro Imaging, Ministry of Education, School of Life Science and Technology, Xidian University & International Joint Research Center for Advanced Medical Imaging and Intelligent Diagnosis and Treatment, Xi'an, Shaanxi 710126, China
| | - Chaoqiang Qiao
- Lab of Molecular Imaging and Translational Medicine (MITM), Engineering Research Center of Molecular and Neuro Imaging, Ministry of Education, School of Life Science and Technology, Xidian University & International Joint Research Center for Advanced Medical Imaging and Intelligent Diagnosis and Treatment, Xi'an, Shaanxi 710126, China
| | - Qian Jia
- Lab of Molecular Imaging and Translational Medicine (MITM), Engineering Research Center of Molecular and Neuro Imaging, Ministry of Education, School of Life Science and Technology, Xidian University & International Joint Research Center for Advanced Medical Imaging and Intelligent Diagnosis and Treatment, Xi'an, Shaanxi 710126, China
| | - Ruili Zhang
- Lab of Molecular Imaging and Translational Medicine (MITM), Engineering Research Center of Molecular and Neuro Imaging, Ministry of Education, School of Life Science and Technology, Xidian University & International Joint Research Center for Advanced Medical Imaging and Intelligent Diagnosis and Treatment, Xi'an, Shaanxi 710126, China
| | - Zhongliang Wang
- Lab of Molecular Imaging and Translational Medicine (MITM), Engineering Research Center of Molecular and Neuro Imaging, Ministry of Education, School of Life Science and Technology, Xidian University & International Joint Research Center for Advanced Medical Imaging and Intelligent Diagnosis and Treatment, Xi'an, Shaanxi 710126, China
| |
Collapse
|
2
|
Le Guével X, Josserand V, Harki O, Baulin VA, Henry M, Briançon-Marjollet A. Real-time visualization of dextran extravasation in intermittent hypoxia mice using noninvasive SWIR imaging. Am J Physiol Heart Circ Physiol 2024; 326:H900-H906. [PMID: 38363213 DOI: 10.1152/ajpheart.00787.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 01/29/2024] [Accepted: 01/29/2024] [Indexed: 02/17/2024]
Abstract
Imaging tools are crucial for studying the vascular network and its barrier function in various physiopathological conditions. Shortwave infrared (SWIR) window optical imaging allows noninvasive, in-depth exploration. We applied SWIR imaging, combined with vessel segmentation and deep learning analyses, to study real-time dextran probe extravasation in mice experiencing intermittent hypoxia (IH)-a characteristic of obstructive sleep apnea associated with potential cardiovascular alterations due to early vascular permeability. Evidence for permeability in this context is limited, making our investigation significant. C57Bl/6 mice were exposed to normoxia or intermittent hypoxia for 14 days. Then SWIR imaging between 1,250 and 1,700 nm was performed on the saphenous artery and vein and on the surrounding tissue after intravenous injection of labeled dextrans of two different sizes (10 or 70 kDa). Postprocessing and segmentation of the SWIR images were conducted using deep learning treatment. We monitored high-resolution signals, distinguishing arteries, veins, and surrounding tissues. In the saphenous artery and vein, after 70-kD dextran injection, tissue/vessel ratio was higher after intermittent hypoxia (IH) than normoxia (N) over 500 seconds (P < 0.05). However, the ratio was similar in N and IH after 10-kD dextran injection. The SWIR imaging technique allows noninvasive, real-time monitoring of dextran extravasation in vivo. Dextran 70 extravasation is increased after exposure to IH, suggesting an increased vessel permeability in this mice model of obstructive sleep apnea.NEW & NOTEWORTHY We demonstrate that SWIR imaging technique is a useful tool to monitor real-time dextran extravasation from vessels in vivo, with a high resolution. We report for the first time an increased real-time dextran (70 kD) extravasation in mice exposed to intermittent hypoxia for 14 days compared with normoxic controls.
Collapse
Affiliation(s)
- Xavier Le Guével
- University grenoble alpes, Institute for Advanced Biosciences, NSERM1209/CNRS-UMR5309, Grenoble, France
| | - Véronique Josserand
- University grenoble alpes, Institute for Advanced Biosciences, NSERM1209/CNRS-UMR5309, Grenoble, France
| | - Olfa Harki
- University grenoble alpes, INSERM U1300, HP2 Laboratory, Grenoble, France
| | - Vladimir A Baulin
- Departament Química Física i Inorgànica, Universitat Rovira i Virgili, Tarragona, Spain
| | - Maxime Henry
- University grenoble alpes, Institute for Advanced Biosciences, NSERM1209/CNRS-UMR5309, Grenoble, France
| | | |
Collapse
|
3
|
Lin X, Chen T. A Review of in vivo Toxicity of Quantum Dots in Animal Models. Int J Nanomedicine 2023; 18:8143-8168. [PMID: 38170122 PMCID: PMC10759915 DOI: 10.2147/ijn.s434842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Accepted: 12/15/2023] [Indexed: 01/05/2024] Open
Abstract
Tremendous research efforts have been devoted to nanoparticles for applications in optoelectronics and biomedicine. Over the past decade, quantum dots (QDs) have become one of the fastest growing areas of research in nanotechnology because of outstanding photophysical properties, including narrow and symmetrical emission spectrum, broad fluorescence excitation spectrum, the tenability of the emission wavelength with the particle size and composition, anti-photobleaching ability and stable fluorescence. These characteristics are suitable for optical imaging, drug delivery and other biomedical applications. Research on QDs toxicology has demonstrated QDs affect or damage the biological system to some extent, and this situation is generally caused by the metal ions and some special properties in QDs, which hinders the further application of QDs in the biomedical field. The toxicological mechanism mainly stems from the release of heavy metal ions and generation of reactive oxygen species (ROS). At the same time, the contact reaction with QDs also cause disorders in organelles and changes in gene expression profiles. In this review, we try to present an overview of the toxicity and related toxicity mechanisms of QDs in different target organs. It is believed that the evaluation of toxicity and the synthesis of environmentally friendly QDs are the primary issues to be addressed for future widespread applications. However, considering the many different types and potential modifications, this review on the potential toxicity of QDs is still not clearly elucidated, and further research is needed on this meaningful topic.
Collapse
Affiliation(s)
- Xiaotan Lin
- School of Basic Medicine, Guangdong Medical University, DongGuan, People’s Republic of China
- Department of Family Planning, Second Clinical Medical College of Jinan University, Shenzhen People’s Hospital, Shenzhen, People’s Republic of China
| | - Tingting Chen
- School of Basic Medicine, Guangdong Medical University, DongGuan, People’s Republic of China
| |
Collapse
|