Saqib M, Kremmer K, Opitz J, Schneider M, Beshchasna N. Evaluation of the Degradation Properties of Plasma Electrolytically Oxidized Mg Alloy AZ31 Using Fluid Dynamic Accelerated Tests for Biodegradable Implants. J Funct Biomater 2024; 15:366. [PMID: 39728166 DOI: 10.3390/jfb15120366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2024] [Revised: 11/22/2024] [Accepted: 11/28/2024] [Indexed: 12/28/2024] Open
Abstract
Magnesium alloys are promising biodegradable implant materials due to their excellent biocompatibility and non-toxicity. However, their poor corrosion resistance limits their application in vivo. Plasma electrolytic oxidation (PEO) is a powerful technique to improve the corrosion resistance of magnesium alloys. In this study, we present the accelerated degradation of PEO-treated AZ31 samples using a fluid dynamic test. The samples were prepared using different concentrations of KOH as an electrolyte along with NaSiO3. The anodizing time and the biasing time were optimized to obtain the increased corrosion resistance. The analysis of the degraded samples using microscopy, SEM EDX measurements, and by calculating mass loss and corrosion rates showed a significant increase in the corrosion resistance after the polymer (Resomer© LG 855 S) coating was applied to the anodized samples. The results confirm (or convince) that PEO treatment is an effective way to improve the corrosion resistance of AZ31 magnesium alloy. The fluid dynamic test can be used as an accelerated degradation test for biodegradable alloys in simulated body fluids at a physiological temperature. The polymer coating further improves the corrosion resistance of the PEO-treated AZ31 samples.
Collapse
Affiliation(s)
- Muhammad Saqib
- Department of Bio and Nanotechnology, Fraunhofer Institute for Ceramic Technologies and Systems IKTS, Maria-Reiche-Strasse 2, 01109 Dresden, Germany
| | - Kerstin Kremmer
- Department of Electrochemistry, Fraunhofer Institute for Ceramic Technologies and Systems IKTS, Winterbergstrasse 28, 01277 Dresden, Germany
| | - Joerg Opitz
- Department of Bio and Nanotechnology, Fraunhofer Institute for Ceramic Technologies and Systems IKTS, Maria-Reiche-Strasse 2, 01109 Dresden, Germany
| | - Michael Schneider
- Department of Electrochemistry, Fraunhofer Institute for Ceramic Technologies and Systems IKTS, Winterbergstrasse 28, 01277 Dresden, Germany
| | - Natalia Beshchasna
- Department of Bio and Nanotechnology, Fraunhofer Institute for Ceramic Technologies and Systems IKTS, Maria-Reiche-Strasse 2, 01109 Dresden, Germany
| |
Collapse
|
2
|
Sun J, Liu SS, Zou D, He X, Shi ZZ, Li WS. How surface-to-volume ratio affects degradation of magnesium: in vitro and in vivo studies. RSC Adv 2024; 14:6805-6814. [PMID: 38405068 PMCID: PMC10887483 DOI: 10.1039/d3ra08927d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Accepted: 02/12/2024] [Indexed: 02/27/2024] Open
Abstract
Despite the many studies carried out over the past decade to determine the biodegradation performance of magnesium and its alloys, few studies focused on the effect of altered surface area to volume ratio on in vitro and in vivo degradation rate and osteogenesis. Here, high purity magnesium cylindrical rods with gradient of surface area to volume ratio were processed by excavating different numbers of grooves on the side surface. The immersion test in SBF solution and the rat femoral condylar bone defect model were used to evaluate the degradation of magnesium rods in vitro and in vivo, respectively. We demonstrated that, the increased number of grooves on the HP magnesium surface represented a decrease in the percentage of residual volume over time, not necessarily an increase in absolute degradation volume or a regular change in corrosion rate. Furthermore, there were strong linear correlations between the relative degradation volume and the initial surface-to-volume ratio of HP magnesium rods both in vitro and in vivo. The difference in the slope of this relationship in vitro and in vivo might help to determine the possible range of in vivo degradation rates via in vitro data. In addition, the corrosion rate is more suitable for evaluating bone formation surrounding the different HP magnesium rods. Our findings in this work may facilitate adjusting the in vivo degradation and osteogenesis of different kinds of orthopedic implants made of the same magnesium-based material, and thus, accelerate the clinical popularization and application.
Collapse
Affiliation(s)
- Jiang Sun
- Peking University Third Hospital Beijing 100191 China
- Engineering Research Center of Bone and Joint Precision Medicine Department of Orthopedics Beijing 100191 China
- Beijing Key Laboratory of Spinal Disease Research Beijing 100191 China
| | - Shan-Shan Liu
- Peking University Third Hospital Beijing 100191 China
- Engineering Research Center of Bone and Joint Precision Medicine Department of Orthopedics Beijing 100191 China
- Beijing Key Laboratory of Spinal Disease Research Beijing 100191 China
| | - Da Zou
- Peking University Third Hospital Beijing 100191 China
- Engineering Research Center of Bone and Joint Precision Medicine Department of Orthopedics Beijing 100191 China
- Beijing Key Laboratory of Spinal Disease Research Beijing 100191 China
| | - Xuan He
- Peking University Third Hospital Beijing 100191 China
- Engineering Research Center of Bone and Joint Precision Medicine Department of Orthopedics Beijing 100191 China
- Beijing Key Laboratory of Spinal Disease Research Beijing 100191 China
| | - Zhang-Zhi Shi
- University of Science and Technology Beijing Beijing 100083 China
| | - Wei-Shi Li
- Peking University Third Hospital Beijing 100191 China
- Engineering Research Center of Bone and Joint Precision Medicine Department of Orthopedics Beijing 100191 China
- Beijing Key Laboratory of Spinal Disease Research Beijing 100191 China
| |
Collapse
|
3
|
Yamada S, Ockermann PN, Schwarz T, Mustafa K, Hansmann J. Translation of biophysical environment in bone into dynamic cell culture under flow for bone tissue engineering. Comput Struct Biotechnol J 2023; 21:4395-4407. [PMID: 37711188 PMCID: PMC10498129 DOI: 10.1016/j.csbj.2023.08.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Revised: 08/14/2023] [Accepted: 08/14/2023] [Indexed: 09/16/2023] Open
Abstract
Bone is a dynamic environment where osteocytes, osteoblasts, and mesenchymal stem/progenitor cells perceive mechanical cues and regulate bone metabolism accordingly. In particular, interstitial fluid flow in bone and bone marrow serves as a primary biophysical stimulus, which regulates the growth and fate of the cellular components of bone. The processes of mechano-sensory and -transduction towards bone formation have been well studied mainly in vivo as well as in two-dimensional (2D) dynamic cell culture platforms, which elucidated mechanically induced osteogenesis starting with anabolic responses, such as production of nitrogen oxide and prostaglandins followed by the activation of canonical Wnt signaling, upon mechanosensation. The knowledge has been now translated into regenerative medicine, particularly into the field of bone tissue engineering, where multipotent stem cells are combined with three-dimensional (3D) scaffolding biomaterials to produce transplantable constructs for bone regeneration. In the presence of 3D scaffolds, the importance of suitable dynamic cell culture platforms increases further not only to improve mass transfer inside the scaffolds but to provide appropriate biophysical cues to guide cell fate. In principle, the concept of dynamic cell culture platforms is rooted to bone mechanobiology. Therefore, this review primarily focuses on biophysical environment in bone and its translation into dynamic cell culture platforms commonly used for 2D and 3D cell expansion, including their advancement, challenges, and future perspectives. Additionally, it provides the literature review of recent empirical studies using 2D and 3D flow-based dynamic cell culture systems for bone tissue engineering.
Collapse
Affiliation(s)
- Shuntaro Yamada
- Center of Translational Oral Research-Tissue Engineering, Department of Clinical Dentistry, Faculty of Medicine, University of Bergen, Norway
| | - Philipp Niklas Ockermann
- Fraunhofer Institute for Silicate Research ISC, Translational Center Regenerative Therapies, Germany
| | - Thomas Schwarz
- Fraunhofer Institute for Silicate Research ISC, Translational Center Regenerative Therapies, Germany
| | - Kamal Mustafa
- Center of Translational Oral Research-Tissue Engineering, Department of Clinical Dentistry, Faculty of Medicine, University of Bergen, Norway
| | - Jan Hansmann
- Fraunhofer Institute for Silicate Research ISC, Translational Center Regenerative Therapies, Germany
- Chair of Tissue Engineering and Regenerative Medicine, University Hospital Würzburg, Germany
- Department of Electrical Engineering, University of Applied Sciences Würzburg-Schweinfurt, Germany
| |
Collapse
|
4
|
van Gaalen K, Quinn C, Benn F, McHugh PE, Kopp A, Vaughan TJ. Linking the effect of localised pitting corrosion with mechanical integrity of a rare earth magnesium alloy for implant use. Bioact Mater 2023; 21:32-43. [PMID: 36017069 PMCID: PMC9396051 DOI: 10.1016/j.bioactmat.2022.08.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 07/20/2022] [Accepted: 08/04/2022] [Indexed: 01/05/2023] Open
Abstract
This study presents a computational framework that investigates the effect of localised surface-based corrosion on the mechanical performance of a magnesium-based alloy. A finite element-based phenomenological corrosion model was used to generate a wide range of corrosion profiles, with subsequent uniaxial tensile test simulations to predict the mechanical response to failure. The python-based detection framework PitScan provides detailed quantification of the spatial phenomenological features of corrosion, including a full geometric tracking of corroding surface. Through this approach, this study is the first to quantitatively demonstrate that a surface-based non-uniform corrosion model can capture both the geometrical and mechanical features of a magnesium alloy undergoing corrosion by comparing to experimental data. Using this verified corrosion modelling approach, a wide range of corrosion scenarios was evaluated and enabled quantitative relationships to be established between the mechanical integrity and key phenomenological corrosion features. In particular, we demonstrated that the minimal cross-sectional area parameter was the strongest predictor of the remaining mechanical strength (R2 = 0.98), with this relationship being independent of the severity or spatial features of localised surface corrosion. Interestingly, our analysis demonstrated that parameters described in ASTM G46-94 showed weaker correlations to the mechanical integrity of corroding specimens, compared to parameters determined by Pitscan. This study establishes new mechanistic insight into the performance of the magnesium-based materials undergoing corrosion.
Collapse
Affiliation(s)
- Kerstin van Gaalen
- Biomechanics Research Centre (BioMEC), Biomedical Engineering, School of Engineering, National University of Ireland Galway, Galway, Ireland
- Meotec GmbH, Aachen, Germany
| | - Conall Quinn
- Biomechanics Research Centre (BioMEC), Biomedical Engineering, School of Engineering, National University of Ireland Galway, Galway, Ireland
| | - Felix Benn
- Meotec GmbH, Aachen, Germany
- School of Mechanical and Aerospace Engineering, Queen's University Belfast, Belfast, United Kingdom
| | - Peter E. McHugh
- Biomechanics Research Centre (BioMEC), Biomedical Engineering, School of Engineering, National University of Ireland Galway, Galway, Ireland
| | | | - Ted J. Vaughan
- Biomechanics Research Centre (BioMEC), Biomedical Engineering, School of Engineering, National University of Ireland Galway, Galway, Ireland
| |
Collapse
|
5
|
Open-porous magnesium-based scaffolds withstand in vitro corrosion under cyclic loading: A mechanistic study. Bioact Mater 2023; 19:406-417. [PMID: 35574056 PMCID: PMC9062748 DOI: 10.1016/j.bioactmat.2022.04.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 04/10/2022] [Accepted: 04/13/2022] [Indexed: 01/05/2023] Open
Abstract
The successful application of magnesium (Mg) alloys as biodegradable bone substitutes for critical-sized defects may be comprised by their high degradation rate resulting in a loss of mechanical integrity. This study investigates the degradation pattern of an open-porous fluoride-coated Mg-based scaffold immersed in circulating Hanks' Balanced Salt Solution (HBSS) with and without in situ cyclic compression (30 N/1 Hz). The changes in morphological and mechanical properties have been studied by combining in situ high-resolution X-ray computed tomography mechanics and digital volume correlation. Although in situ cyclic compression induced acceleration of the corrosion rate, probably due to local disruption of the coating layer where fatigue microcracks were formed, no critical failures in the overall scaffold were observed, indicating that the mechanical integrity of the Mg scaffolds was preserved. Structural changes, due to the accumulation of corrosion debris between the scaffold fibres, resulted in a significant increase (p < 0.05) in the material volume fraction from 0.52 ± 0.07 to 0.47 ± 0.03 after 14 days of corrosion. However, despite an increase in fibre material loss, the accumulated corrosion products appear to have led to an increase in Young's modulus after 14 days as well as lower third principal strain (εp3) accumulation (−91000 ± 6361 με and −60093 ± 2414 με after 2 and 14 days, respectively). Therefore, this innovative Mg scaffold design and composition provide a bone replacement, capable of sustaining mechanical loads in situ during the postoperative phase allowing new bone formation to be initially supported as the scaffold resorbs. First report on in vitro cyclic loading of MgF2 coated open-porous Mg scaffolds in HBSS simulating 2–3 months in humans. Fluoride-coating slows down corrosion under cyclic loading in vitro. Entangled scaffold structure accumulates local corrosion debris which keeps the mechanical integrity over 14 days in vitro.
Collapse
|
6
|
Potential bioactive coating system for high-performance absorbable magnesium bone implants. Bioact Mater 2022; 12:42-63. [PMID: 35087962 PMCID: PMC8777287 DOI: 10.1016/j.bioactmat.2021.10.034] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Revised: 10/21/2021] [Accepted: 10/21/2021] [Indexed: 12/11/2022] Open
Abstract
Magnesium alloys are considered the most suitable absorbable metals for bone fracture fixation implants. The main challenge in absorbable magnesium alloys is their high corrosion/degradation rate that needs to be controlled. Various coatings have been applied to magnesium alloys to slow down their corrosion rates to match their corrosion rate to the regeneration rate of the bone fracture. In this review, a bioactive coating is proposed to slow down the corrosion rate of magnesium alloys and accelerate the bone fracture healing process. The main aim of the bioactive coatings is to enhance the direct attachment of living tissues and thereby facilitate osteoconduction. Hydroxyapatite, collagen type I, recombinant human bone morphogenetic proteins 2, simvastatin, zoledronate, and strontium are six bioactive agents that show high potential for developing a bioactive coating system for high-performance absorbable magnesium bone implants. In addition to coating, the substrate itself can be made bioactive by alloying magnesium with calcium, zinc, copper, and manganese that were found to promote bone regeneration. Bioactive-coated magnesium implant could accelerate bone fracture healing time to match with magnesium degradation. Hydroxyapatite, collagen type I, recombinant human bone morphogenetic proteins 2, simvastatin, zoledronate, and strontium are high potential bioactive coating materials. The incorporation of Ca, Zn, Cu, Sr, and Mn in Mg base-metal could further enhance bone formation.
Collapse
|
7
|
Xue J, Singh S, Zhou Y, Perdomo-Pantoja A, Tian Y, Gupta N, Witham T, Grayson WL, Weihs TP. A biodegradable 3D woven magnesium-based scaffold for orthopedic implants. Biofabrication 2022; 14. [DOI: 10.1088/1758-5090/ac73b8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Accepted: 05/26/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Porous Magnesium (Mg) is a promising biodegradable scaffold for treating critical-size bone defects, and as an essential element for human metabolism, Mg has shown sufficient biocompatibility. Its elastic moduli and yield strengths are closer to those of cortical bone than common, inert metallic implants, effectively reducing stress concentrations around host tissue as well as stress shielding. More importantly, Mg can degrade and be absorbed in the human body in a safe and controlled manner, thereby reducing the need for second surgeries to remove implants. The development of porous Mg scaffolds via conventional selective laser melting (SLM) techniques has been limited due to Mg’s low boiling point, high vapor pressures, high reactivity, and non-ideal microstructures in additively manufactured parts. Here we present an exciting alternative to conventional additive techniques: 3D weaving with Mg wires that have controlled chemistries and microstructures. The weaving process offers high throughput manufacturing as well as porous architectures that can be optimized for stiffness and porosity with topology optimization. Once woven, we dip-coat the weaves with polylactic acid (PLA) to enhance their strength and corrosion resistance. Following fabrication, we characterize their mechanical properties, corrosion behavior, and cell compatibility in vitro, and we use an intramuscular implantation model to evaluate their in vivo corrosion behavior and tissue response.
Collapse
|
8
|
van Gaalen K, Gremse F, Benn F, McHugh PE, Kopp A, Vaughan TJ. Automated ex-situ detection of pitting corrosion and its effect on the mechanical integrity of rare earth magnesium alloy - WE43. Bioact Mater 2021; 8:545-558. [PMID: 34541419 PMCID: PMC8435990 DOI: 10.1016/j.bioactmat.2021.06.024] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 06/09/2021] [Accepted: 06/22/2021] [Indexed: 01/26/2023] Open
Abstract
This study develops a three-dimensional automated detection framework (PitScan) that systematically evaluates the severity and phenomenology of pitting corrosion. This framework uses a python-based algorithm to analyse microcomputer-tomography scans (μCT) of cylindrical specimens undergoing corrosion. The approach systematically identifies several surface-based corrosion features, enabling full spatial characterisation of pitting parameters, including pit density, pit size, pit depth as well as pitting factor according to ASTM G46-94. Furthermore, it is used to evaluate pitting formation in tensile specimens of a Rare Earth Magnesium alloy undergoing corrosion, and relationships between key pitting parameters and mechanical performance are established. Results demonstrated that several of the parameters described in ASTM G46-94, including pit number, pit density and pitting factor, showed little correlation to mechanical performance. However, this study did identify that other parameters showed strong correlations with the ultimate tensile strength and these tended to be directly linked to the reduction of the cross-sectional area of the specimen. Specifically, our results indicate, that parameters directly linked to the loss of the cross-sectional area (e.g. minimum material width), are parameters that are most suited to provide an indication of a specimen's mechanical performance. The automated detection framework developed in this study has the potential to provide a basis to standardise measurements of pitting corrosion across a range of metals and future prediction of mechanical strength over degradation time. In-vitro immersion study of dog bones manufactured from a WE43 Magnesium alloy. Novel approach characterizing spatial pit formation using micro-CT scans. Comparison of mass loss by hydrogen gas measurement and volume loss by μCT scans. Correlation between mechanical strength and geometrical pit formation features.
Collapse
Affiliation(s)
- Kerstin van Gaalen
- Biomechanics Research Centre (BioMEC), Biomedical Engineering, School of Engineering, College of Science and Engineering, National University of Ireland Galway, Galway, Ireland.,Meotec GmbH, Aachen, Germany
| | - Felix Gremse
- Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - Felix Benn
- School of Mechanical and Aerospace Engineering, Queen's University Belfast, Belfast, United Kingdom.,Meotec GmbH, Aachen, Germany
| | - Peter E McHugh
- Biomechanics Research Centre (BioMEC), Biomedical Engineering, School of Engineering, College of Science and Engineering, National University of Ireland Galway, Galway, Ireland
| | | | - Ted J Vaughan
- Biomechanics Research Centre (BioMEC), Biomedical Engineering, School of Engineering, College of Science and Engineering, National University of Ireland Galway, Galway, Ireland
| |
Collapse
|
9
|
Amukarimi S, Mozafari M. Biodegradable magnesium-based biomaterials: An overview of challenges and opportunities. MedComm (Beijing) 2021; 2:123-144. [PMID: 34766139 PMCID: PMC8491235 DOI: 10.1002/mco2.59] [Citation(s) in RCA: 48] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 01/10/2021] [Accepted: 01/14/2021] [Indexed: 12/26/2022] Open
Abstract
As promising biodegradable materials with nontoxic degradation products, magnesium (Mg) and its alloys have received more and more attention in the biomedical field very recently. Having excellent biocompatibility and unique mechanical properties, magnesium-based alloys currently cover a broad range of applications in the biomedical field. The use of Mg-based biomedical devices eliminates the need for biomaterial removal surgery after the healing process and reduces adverse effects induced by the implantation of permanent biomaterials. However, the high corrosion rate of Mg-based implants leads to unexpected degradation, structural failure, hydrogen evolution, alkalization, and cytotoxicity. To overcome these limitations, alloying Mg with suitable alloying elements and surface treatment come highly recommended. In this area, open questions remain on the behavior of Mg-based biomaterials in the human body and the effects of different factors that have resulted in these challenges. In addition to that, many techniques are yet to be verified to turn these challenges into opportunities. Accordingly, this article aims to review major challenges and opportunities for Mg-based biomaterials to minimize the challenges for the development of novel biomaterials made of Mg and its alloys.
Collapse
Affiliation(s)
- Shukufe Amukarimi
- Department of Tissue Engineering & Regenerative Medicine, Faculty of Advanced Technologies in MedicineIran University of Medical Sciences (IUMS)TehranIran
| | - Masoud Mozafari
- Department of Tissue Engineering & Regenerative Medicine, Faculty of Advanced Technologies in MedicineIran University of Medical Sciences (IUMS)TehranIran
| |
Collapse
|
10
|
Jung O, Porchetta D, Schroeder ML, Klein M, Wegner N, Walther F, Feyerabend F, Barbeck M, Kopp A. In Vivo Simulation of Magnesium Degradability Using a New Fluid Dynamic Bench Testing Approach. Int J Mol Sci 2019; 20:ijms20194859. [PMID: 31574947 PMCID: PMC6801401 DOI: 10.3390/ijms20194859] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2019] [Revised: 09/21/2019] [Accepted: 09/23/2019] [Indexed: 12/12/2022] Open
Abstract
The degradation rate of magnesium (Mg) alloys is a key parameter to develop Mg-based biomaterials and ensure in vivo-mechanical stability as well as to minimize hydrogen gas production, which otherwise can lead to adverse effects in clinical applications. However, in vitro and in vivo results of the same material often differ largely. In the present study, a dynamic test bench with several single bioreactor cells was constructed to measure the volume of hydrogen gas which evolves during magnesium degradation to indicate the degradation rate in vivo. Degradation medium comparable with human blood plasma was used to simulate body fluids. The media was pumped through the different bioreactor cells under a constant flow rate and 37 °C to simulate physiological conditions. A total of three different Mg groups were successively tested: Mg WE43, and two different WE43 plasma electrolytically oxidized (PEO) variants. The results were compared with other methods to detect magnesium degradation (pH, potentiodynamic polarization (PDP), cytocompatibility, SEM (scanning electron microscopy)). The non-ceramized specimens showed the highest degradation rates and vast standard deviations. In contrast, the two PEO samples demonstrated reduced degradation rates with diminished standard deviation. The pH values showed above-average constant levels between 7.4–7.7, likely due to the constant exchange of the fluids. SEM revealed severe cracks on the surface of WE43 after degradation, whereas the ceramized surfaces showed significantly decreased signs of corrosion. PDP results confirmed the improved corrosion resistance of both PEO samples. While WE43 showed slight toxicity in vitro, satisfactory cytocompatibility was achieved for the PEO test samples. In summary, the dynamic test bench constructed in this study enables reliable and simple measurement of Mg degradation to simulate the in vivo environment. Furthermore, PEO treatment of magnesium is a promising method to adjust magnesium degradation.
Collapse
Affiliation(s)
- Ole Jung
- Department of Oral Maxillofacial Surgery, University Medical Center, 20246 Hamburg-Eppendorf, Germany.
| | - Dario Porchetta
- Department of Materials Test Engineering (WPT), TU Dortmund University, 44227 Dortmund, Germany.
- Meotec GmbH, 52068 Aachen, Germany.
| | - Marie-Luise Schroeder
- Department of Oral Maxillofacial Surgery, University Medical Center, 20246 Hamburg-Eppendorf, Germany.
| | - Martin Klein
- Department of Materials Test Engineering (WPT), TU Dortmund University, 44227 Dortmund, Germany.
| | - Nils Wegner
- Department of Materials Test Engineering (WPT), TU Dortmund University, 44227 Dortmund, Germany.
| | - Frank Walther
- Department of Materials Test Engineering (WPT), TU Dortmund University, 44227 Dortmund, Germany.
| | - Frank Feyerabend
- Institute of Materials Research, Division Metallic Biomaterials, Helmholtz-Zentrum Geesthacht, 21502 Geesthacht, Germany.
| | - Mike Barbeck
- Department of Oral Maxillofacial Surgery, University Medical Center, 20246 Hamburg-Eppendorf, Germany.
- BerlinAnalytix GmbH, 12109 Berlin, Germany.
| | | |
Collapse
|
11
|
Wang X, Shao X, Dai T, Xu F, Zhou JG, Qu G, Tian L, Liu B, Liu Y. In vivo study of the efficacy, biosafety, and degradation of a zinc alloy osteosynthesis system. Acta Biomater 2019; 92:351-361. [PMID: 31059834 DOI: 10.1016/j.actbio.2019.05.001] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2018] [Revised: 04/26/2019] [Accepted: 05/01/2019] [Indexed: 01/11/2023]
Abstract
In this study, a comprehensive analysis of a novel zinc alloy osteosynthesis system in a canine mandibular fracture model is presented. The efficacy of the system was compared for PLLA (poly-l-lactic acid) and titanium materials using X-ray radiography, micro-CT tomography, undecalcified bone histomorphometry, and a three-point bending test. Histology, blood normal, blood biochemical, and serum zinc concentration tests were also performed to assess the biosafety of the zinc alloy osteosynthesis system. The degradability of the zinc alloy was evaluated using a micro-CT and scanning electron microscope during the 24-week post operation period. The results showed that zinc alloy possesses good mechanical properties that support fracture healing. Its uniform and slow corrosion leads to adequate degradation behavior in 24 weeks. Additionally, the zinc alloy proved to be biocompatible, indicating that this novel osteosynthesis system is safe for use in the body. The results of the study demonstrate that this zinc alloy-based osteosynthesis system is a promising candidate for a new generation of osteosynthesis systems, with further improvements required in the future.
Collapse
|
12
|
Gu XN, Lu Y, Wang F, Lin W, Li P, Fan Y. The effect of tensile and fluid shear stress on the in vitro degradation of magnesium alloy for stent applications. Bioact Mater 2018; 3:448-454. [PMID: 30182072 PMCID: PMC6120427 DOI: 10.1016/j.bioactmat.2018.08.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Revised: 08/27/2018] [Accepted: 08/27/2018] [Indexed: 12/27/2022] Open
Abstract
Magnesium alloys have gained great attention as biodegradable materials for stent applications. Cardiovascular stents are continuously exposed to different types of mechanical loadings simultaneously during service, including tensile, compressive and fluid shear stress. In this study, the in vitro degradation of WE43 wires was investigated under combined effect of tensile loading and fluid shear stress and compared with that experienced an individual loading condition. For the individual mechanical loading treatment, the degradation of magnesium wires was more severely affected by tensile loading than fluid shear stress. Under tensile loading, magnesium wires showed faster increment of corrosion rates, loss of mechanical properties and localized corrosion morphology with the increasing tensile loadings. With the combined stress, smaller variation of the corrosion rates as well as the slower strength degeneration was shown with increasing stress levels, in comparison with the individual treatment of tensile loading. This study could help to understand the effect of complex stress condition on the corrosion of magnesium for the optimization of biodegradable magnesium stents. Tensile loading induced the localized corrosion and fast degeneration of mechanical properties of magnesium wires. Relatively homogeneous corrosion of magnesium wires was observed under fluid shear stress. Under combined stresses, smaller variation of the corrosion rates and the slower strength decay was shown with increasing stresses.
Collapse
Affiliation(s)
- Xue-Nan Gu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, 10083, China.,Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing, 102402, China
| | - Yun Lu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, 10083, China
| | - Fan Wang
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, 10083, China
| | - Wenting Lin
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, 10083, China
| | - Ping Li
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, 10083, China.,Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing, 102402, China
| | - Yubo Fan
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, 10083, China.,Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing, 102402, China.,National Research Center for Rehabilitation Technical Aids, Beijing, 100176, China
| |
Collapse
|
13
|
Biodegradable Metallic Wires in Dental and Orthopedic Applications: A Review. METALS 2018. [DOI: 10.3390/met8040212] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
14
|
Wang J, Wu Y, Li H, Liu Y, Bai X, Chau W, Zheng Y, Qin L. Magnesium alloy based interference screw developed for ACL reconstruction attenuates peri-tunnel bone loss in rabbits. Biomaterials 2018; 157:86-97. [DOI: 10.1016/j.biomaterials.2017.12.007] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2017] [Revised: 12/05/2017] [Accepted: 12/10/2017] [Indexed: 01/03/2023]
|