1
|
Shin EJ, Park S, Kang S, Kim J, Chang JH. Improving the quality of ultrasound images acquired using a therapeutic transducer. ULTRASONICS 2023; 134:107063. [PMID: 37300907 DOI: 10.1016/j.ultras.2023.107063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 05/01/2023] [Accepted: 05/30/2023] [Indexed: 06/12/2023]
Abstract
To enhance the effectiveness and safety of focused ultrasound (FUS) therapy, ultrasound image-based guidance and treatment monitoring are crucial. However, the use of FUS transducers for both therapy and imaging is impractical due to their low spatial resolution, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). To address this issue, we propose a new method that significantly improve the quality of images obtained by a FUS transducer. The proposed method employs coded excitation to enhance SNR and Wiener deconvolution to solve the problem of low axial resolution resulting from the narrow spectral bandwidth of FUS transducers. Specifically, the method eliminates the impulse response of a FUS transducer from received ultrasound signals using Wiener deconvolution, and pulse compression is performed using a mismatched filter. Simulation and commercial phantom experiments confirmed that the proposed method significantly improves the quality of images acquired by the FUS transducer. The -6 dB axial resolution was improved 1.27 mm to 0.37 mm that was similar to the resolution achieved by the imaging transducer, i.e., 0.33 mm. SNR and CNR also increased from 16.5 dB and 0.69 to 29.1 dB and 3.03, respectively, that were also similar to those by the imaging transducer (27.8 dB and 3.16). Based on the results, we believe that the proposed method has great potential to enhance the clinical utility of FUS transducers in ultrasound image-guided therapy.
Collapse
Affiliation(s)
- Eui-Ji Shin
- Department of Electronic Engineering, Sogang University, Seoul, Korea
| | - Sunghun Park
- Department of Electronic Engineering, Sogang University, Seoul, Korea
| | - Sungwoo Kang
- Department of Electrical Engineering and Computer Science, DGIST (Daegu Gyeongbuk Institute of Science and Technology), Daegu, Korea
| | - Jinwoo Kim
- Department of Electrical Engineering and Computer Science, DGIST (Daegu Gyeongbuk Institute of Science and Technology), Daegu, Korea
| | - Jin Ho Chang
- Department of Electrical Engineering and Computer Science, DGIST (Daegu Gyeongbuk Institute of Science and Technology), Daegu, Korea.
| |
Collapse
|
2
|
Park J, Kong C, Shin J, Park JY, Na YC, Han SH, Chang JW, Song SH, Chang WS. Combined Effects of Focused Ultrasound and Photodynamic Treatment for Malignant Brain Tumors Using C6 Glioma Rat Model. Yonsei Med J 2023; 64:233-242. [PMID: 36996894 PMCID: PMC10067799 DOI: 10.3349/ymj.2022.0422] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 02/09/2023] [Accepted: 02/16/2023] [Indexed: 04/01/2023] Open
Abstract
PURPOSE Glioblastoma (GBM) is an intractable disease for which various treatments have been attempted, but with little effect. This study aimed to measure the effect of photodynamic therapy (PDT) and sonodynamic therapy (SDT), which are currently being used to treat brain tumors, as well as sono-photodynamic therapy (SPDT), which is the combination of these two. MATERIALS AND METHODS Four groups of Sprague-Dawley rats were injected with C6 glioma cells in a cortical region and treated with PDT, SDT, and SPDT. Gd-MRI was monitored weekly and 18F-FDG-PET the day before and 1 week after the treatment. The acoustic power used during sonication was 5.5 W/cm² using a 0.5-MHz single-element transducer. The 633-nm laser was illuminated at 100 J/cm². Oxidative stress and apoptosis markers were evaluated 3 days after treatment using immunohistochemistry (IHC): 4-HNE, 8-OhdG, and Caspase-3. RESULTS A decrease in tumor volume was observed in MRI imaging 12 days after the treatment in the PDT group (p<0.05), but the SDT group showed a slight increase compared to the 5-Ala group. The high expression rates of reactive oxygen species-related factors, such as 8-OhdG (p<0.001) and Caspase-3 (p<0.001), were observed in the SPDT group compared to other groups in IHC. CONCLUSION Our findings show that light with sensitizers can inhibit GBM growth, but not ultrasound. Although SPDT did not show the combined effect in MRI, high oxidative stress was observed in IHC. Further studies are needed to investigate the safety parameters to apply ultrasound in GBM.
Collapse
Affiliation(s)
- Junwon Park
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, Korea
| | - Chanho Kong
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, Korea
| | - Jaewoo Shin
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, Korea
| | - Ji Young Park
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, Korea
| | - Young Cheol Na
- Department of Neurosurgery, Catholic Kwandong University College of Medicine, International St. Mary's Hospital, Incheon, Korea
| | - Seung Hee Han
- Department of Medical Biophysics, University of Toronto, Toronto, Canada
| | - Jin Woo Chang
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, Korea
| | - Seung Hyun Song
- Department of Electronics Engineering, Sookmyung Women's University, Seoul, Korea.
| | - Won Seok Chang
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, Korea.
| |
Collapse
|
3
|
Wray PR, Eslamisaray MA, Nelson GM, Ilic O, Kortshagen UR, Atwater HA. Broadband, Angle- and Polarization-Invariant Antireflective and Absorbing Films by a Scalable Synthesis of Monodisperse Silicon Nanoparticles. ACS APPLIED MATERIALS & INTERFACES 2022; 14:23624-23636. [PMID: 35549027 DOI: 10.1021/acsami.2c03263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Optically induced magnetic resonances (OMRs) are highly tunable scattering states that cannot be reproduced in systems that only support electric resonances, such as in metals, lossy, or low-index materials. Despite offering unique scattering and coupling behavior, the study of OMRs in thin films has been limited by synthesis and simulation constraints. We report on the absorption and scattering response of OMR-based thin films composed of monodisperse crystalline silicon nanoparticles synthesized using a scalable nonthermal plasma growth technique and tractable simulation framework. The synthesis is solvent and ligand free, ensuring minimal contamination, and crystalline particles form with high yield and a narrow size distribution at close to room temperature. Using a scalable high-throughput deposition method, we deposit random particle films, without the need of a solid host matrix, showing near complete blackbody absorption at the collective OMR. This is achieved using 70% less material than an optimized antireflective-coated crystalline silicon thin film. The film exhibits strongly directional forward scattering with very low reflectivity, thus giving rise to angle- and polarization-insensitive antireflection properties across the visible spectrum. We find that, while commonly used effective medium models cannot capture the optical response, a modified effective medium accounting for multipole resonances and interparticle coupling shows excellent agreement with experiment. The effective permittivity and permeability are written in a mode and cluster resolved form, providing useful insight into how individual resonances and nanoparticle clusters affect the overall film response. Electric and magnetic-mode coupling show dramatically different behavior, resulting in uniquely different spectral broadening.
Collapse
Affiliation(s)
- Parker R Wray
- Department of Electrical Engineering, California Institute of Technology, Pasadena, California 91125, United States
| | - Mohammad Ali Eslamisaray
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Gunnar M Nelson
- Department of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Ognjen Ilic
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Uwe R Kortshagen
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Harry A Atwater
- Thomas J. Watson Laboratories of Applied Physics, California Institute of Technology, Pasadena, California 91125, United States
| |
Collapse
|
4
|
Fan W, Cui J, Li Q, Huo Y, Xiao D, Yang X, Yu H, Wang C, Jarvis P, Lyu T, Huo M. Bactericidal efficiency and photochemical mechanisms of micro/nano bubble-enhanced visible light photocatalytic water disinfection. WATER RESEARCH 2021; 203:117531. [PMID: 34388494 DOI: 10.1016/j.watres.2021.117531] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 07/28/2021] [Accepted: 08/03/2021] [Indexed: 06/13/2023]
Abstract
Microbial contamination of water in the form of highly-resistant bacterial spores can cause a long-term risk of waterborne disease. Advanced photocatalysis has become an effective approach to inactivate bacterial spores due to its potential for efficient solar energy conversion alongside reduced formation of disinfection by-products. However, the overall efficiency of the process still requires significant improvements. Here, we proposed and evaluated a novel visible light photocatalytic water disinfection technology by its close coupling with micro/nano bubbles (MNBs). The inactivation rate constant of Bacillus subtilis spores reached 1.28 h-1, which was 5.6 times higher than that observed for treatment without MNBs. The superior performance for the progressive destruction of spores' cells during the treatment was confirmed by transmission electron microscopy (TEM) and excitation-emission matrix (EEM) spectra determination. Experiments using scavengers of reactive oxygen species (ROSs) revealed that H2O2 and •OH were the primary active species responsible for the inactivation of spores. The effective supply of oxygen from air MNBs helped accelerate the hole oxidation of H2O2 on the photocatalyst (i.e. Ag/TiO2). In addition, the interfacial photoelectric effect from the MNBs was also confirmed to contribute to the spore inactivation. Specifically, MNBs induced strong light scattering, consequently increasing the optical path length in the photocatalysis medium by 54.8% at 700nm and enhancing light adsorption of the photocatalyst. The non-uniformities in dielectricity led to a high-degree of heterogeneity of the electric field, which triggered the formation of a region of enhanced light intensity which ultimately promoted the photocatalytic reaction. Overall, this study provided new insights on the mechanisms of photocatalysis coupled with MNB technology for advanced water treatment.
Collapse
Affiliation(s)
- Wei Fan
- School of Environment, Northeast Normal University, 2555 Jingyue Street, Changchun 130117, China
| | - Jingyu Cui
- School of Environment, Northeast Normal University, 2555 Jingyue Street, Changchun 130117, China
| | - Qi Li
- School of Environment, Northeast Normal University, 2555 Jingyue Street, Changchun 130117, China
| | - Yang Huo
- National Demonstration Center for Experimental Physics Education, Northeast Normal University, Changchun 130024, China
| | - Dan Xiao
- Jilin Academy of Agricultural Science, 1363 Shengtai Street, Changchun 130033, China
| | - Xia Yang
- School of Environment, Northeast Normal University, 2555 Jingyue Street, Changchun 130117, China
| | - Hongbin Yu
- School of Environment, Northeast Normal University, 2555 Jingyue Street, Changchun 130117, China
| | - Chunliang Wang
- National Demonstration Center for Experimental Physics Education, Northeast Normal University, Changchun 130024, China.
| | - Peter Jarvis
- Cranfield Water Science Institute, Cranfield University, College Road, Cranfield, Bedfordshire MK43 0AL, United Kingdom
| | - Tao Lyu
- Cranfield Water Science Institute, Cranfield University, College Road, Cranfield, Bedfordshire MK43 0AL, United Kingdom.
| | - Mingxin Huo
- School of Environment, Northeast Normal University, 2555 Jingyue Street, Changchun 130117, China
| |
Collapse
|
5
|
Li H, Wu Z, Zhang J, Sun X, Duan F, Yao J, Sun M, Zhang J, Nie L. Instant Ultrasound-Evoked Precise Nanobubble Explosion and Deep Photodynamic Therapy for Tumors Guided by Molecular Imaging. ACS APPLIED MATERIALS & INTERFACES 2021; 13:21097-21107. [PMID: 33908256 DOI: 10.1021/acsami.1c05517] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Nanobubbles (NBs) have recently gained interest in cancer imaging and therapy due to the fact that nanoparticles with the size range of 1-1000 nm can extravasate into permeable tumor types through the enhanced permeability and retention (EPR) effect. However, the therapeutic study of NBs was only limited to drug delivery or cavitation. Herein, we developed ultrasound-evoked massive NB explosion to strikingly damage the surrounding cancer. The dual-function agent allows synergistic mechanical impact and photodynamic therapy of the tumors and enhances imaging contrast. Moreover, the mechanical explosion improved the light delivery efficiency in biological tissue to promote the effect of photodynamic therapy. Under ultrasound/photoacoustic imaging guidance, we induced on-the-spot bubble explosion and photodynamic therapy of tumors at a depth of centimeters in vivo. The mechanical impact of the explosion can enhance delivery of the photosensitizers. Ultrasound explicitly revealed the cancer morphology and exhibited fast NB perfusion. Generated mechanical damage and release of mixture agents demonstrated remarkable synergetic anticancer effects on deep tumors. This finding also offers a new approach and insight into treating cancers.
Collapse
Affiliation(s)
- Honghui Li
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics & Center for Molecular Imaging and Translational Medicine, School of Public Health, Xiamen University, Xiamen 361102, China
| | - Zhiyou Wu
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics & Center for Molecular Imaging and Translational Medicine, School of Public Health, Xiamen University, Xiamen 361102, China
- Research Center of Medical Sciences & Department of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510080, China
| | - Jinde Zhang
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics & Center for Molecular Imaging and Translational Medicine, School of Public Health, Xiamen University, Xiamen 361102, China
| | - Xiang Sun
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics & Center for Molecular Imaging and Translational Medicine, School of Public Health, Xiamen University, Xiamen 361102, China
| | - Fei Duan
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics & Center for Molecular Imaging and Translational Medicine, School of Public Health, Xiamen University, Xiamen 361102, China
| | - Junjie Yao
- Photoacoustic Imaging Laboratory, Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Mingyang Sun
- Department of Anesthesiology and Perioperative Medicine, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Zhengzhou, Henan 450003, People's Republic of China
| | - Jiaqiang Zhang
- Department of Anesthesiology and Perioperative Medicine, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Zhengzhou, Henan 450003, People's Republic of China
| | - Liming Nie
- Research Center of Medical Sciences & Department of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510080, China
| |
Collapse
|
6
|
Kim H, Lee H, Kim H, Chang JH. Elimination of Nontargeted Photoacoustic Signals for Combined Photoacoustic and Ultrasound Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:1593-1604. [PMID: 33259296 DOI: 10.1109/tuffc.2020.3041634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
As a molecular imaging modality, photoacoustic (PA) imaging has been in the spotlight because it can provide an optical contrast image of physiological information and a relatively deep imaging depth. However, its sensitivity is limited despite the use of exogenous contrast agents due to the background PA signals generated from nontargeted absorbers, such as blood and boundaries between different biological tissues. In addition, clutter artifacts generated in both in-plane and out-of-plane imaging region degrade the sensitivity of PA imaging. We propose a method to eliminate the nontargeted PA signals. For this study, we used a dual-modal ultrasound (US)-PA contrast agent that is capable of generating both the backscattered US and PA signals in response to the transmitted US and irradiated light, respectively. The US images of the contrast agents are used to construct a masking image that contains the location information about the target site and is applied to the PA image acquired after contrast agent injection. In vitro and in vivo experimental results demonstrated that the masking image constructed using the US images makes it possible to completely remove nontargeted PA signals. The proposed method can be used to enhance the clear visualization of the target area in PA images.
Collapse
|
7
|
Jang J, Kim J, Lee HJ, Chang JH. Transrectal Ultrasound and Photoacoustic Imaging Probe for Diagnosis of Prostate Cancer. SENSORS 2021; 21:s21041217. [PMID: 33572287 PMCID: PMC7915711 DOI: 10.3390/s21041217] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 02/05/2021] [Accepted: 02/05/2021] [Indexed: 12/27/2022]
Abstract
A combined transrectal ultrasound and photoacoustic (TRUS-PA) imaging probe was developed for the clear visualization of morphological changes and microvasculature distribution in the prostate, as this is required for accurate diagnosis and biopsy. The probe consisted of a miniaturized 128-element 7 MHz convex array transducer with 134.5° field-of-view (FOV), a bifurcated optical fiber bundle, and two optical lenses. The design goal was to make the size of the TRUS-PA probe similar to that of general TRUS probes (i.e., about 20 mm), for the convenience of the patients. New flexible printed circuit board (FPCB), acoustic structure, and optical lens were developed to meet the requirement of the probe size, as well as to realize a high-performance TRUS-PA probe. In visual assessment, the PA signals obtained with the optical lens were 2.98 times higher than those without the lens. Moreover, the in vivo experiment with the xenograft BALB/c (Albino, Immunodeficient Inbred Strain) mouse model showed that TRUS-PA probe was able to acquire the entire PA image of the mouse tight behind the porcine intestine about 25 mm depth. From the ex vivo and in vivo experimental results, it can be concluded that the developed TRUS-PA probe is capable of improving PA image quality, even though the TRUS-PA probe has a cross-section size and an FOV comparable to those of general TRUS probes.
Collapse
Affiliation(s)
- Jihun Jang
- Department of Electronic Engineering, Sogang University, Seoul 04107, Korea;
| | - Jinwoo Kim
- Department of Information and Communnication Engineering, Daegu Gyeongbuk Institute of Science and Technology, Daegu 42988, Korea;
| | - Hak Jong Lee
- Department of Radiology, Seoul National University of Bundang Hospital, Seongnam-si 13620, Korea;
| | - Jin Ho Chang
- Department of Information and Communnication Engineering, Daegu Gyeongbuk Institute of Science and Technology, Daegu 42988, Korea;
- Correspondence: ; Tel.: +82-53-785-6330
| |
Collapse
|
8
|
Chen Q, Ren Y, Yin Y, Qi H. Anisotropic scattering characteristics of nanoparticles in different morphologies: improving the temperature uniformity of tumors during thermal therapy using forward scattering. BIOMEDICAL OPTICS EXPRESS 2021; 12:893-906. [PMID: 33680548 PMCID: PMC7901328 DOI: 10.1364/boe.415666] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 12/29/2020] [Accepted: 01/08/2021] [Indexed: 05/18/2023]
Abstract
Precise control of the thermal damage area is the key issue during thermal therapy, which can be achieved by manipulating the light propagation in biological tissue. In the present work, a method is proposed to increase the uniformity of the specific absorption rate (SAR) distribution in tumors during laser-induced thermal therapy, which is proved to be effective in reducing the thermal damage of healthy tissue. In addition, a better way of manipulating light propagation in biological tissue is explored. It is found that the anisotropic scattering characteristics of nanoparticles are strongly dependent on their shapes, sizes, orientations, and incident wavelengths, which will strongly affect the light propagation in nanoparticle embedded biological tissue. Therefore, to obtain a better outcome from photothermal therapy, the scattering properties of nanoparticles are very important factors that need to be taken into consideration, along with the absorption efficiency. Further investigation finds that nanoparticles that predominantly scatter to the forward direction are favorable in obtaining a larger penetration depth of light, which will improve the uniformity of SAR and temperature distributions. This paper is meaningful for the application of nanoparticle-assisted laser-induced thermal therapy.
Collapse
Affiliation(s)
- Qin Chen
- School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China
- Faculty of Engineering, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Yatao Ren
- School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China
- Faculty of Engineering, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Yanmei Yin
- School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China
| | - Hong Qi
- School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China
| |
Collapse
|
9
|
Kim J, Shin J, Kong C, Lee SH, Chang WS, Han SH. The synergistic effect of focused ultrasound and biophotonics to overcome the barrier of light transmittance in biological tissue. Photodiagnosis Photodyn Ther 2021; 33:102173. [PMID: 33529746 DOI: 10.1016/j.pdpdt.2020.102173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2020] [Revised: 12/09/2020] [Accepted: 12/23/2020] [Indexed: 11/28/2022]
Abstract
Optical technology is a tool to diagnose and treat human diseases. Shallow penetration depth caused by the high optical scattering nature of biological tissues is a significant obstacle to utilizing light in the biomedical field. In this paper, light transmission enhancement in the rat brain induced by focused ultrasound (FUS) was observed and the cause of observed enhancement was analyzed. Both air bubbles and mechanical deformation generated by FUS were cited as the cause. The Monte Carlo simulation was performed to investigate effects on transmission by air bubbles and finite element method was also used to describe mechanical deformation induced by motions of acoustic particles. As a result, it was found that the mechanical deformation was more suitable to describe the transmission change according to the FUS pulse observed in the experiment.
Collapse
Affiliation(s)
- Jaehyuk Kim
- Molecular Imaging, Princess Margaret Cancer Centre, Toronto, ON, Canada; Health and Medical Equipment, Samsung Electronics Co. Ltd., Suwon, Republic of Korea
| | - Jaewoo Shin
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Chanho Kong
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Sung-Ho Lee
- Molecular Imaging, Princess Margaret Cancer Centre, Toronto, ON, Canada
| | - Won Seok Chang
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Seung Hee Han
- Molecular Imaging, Princess Margaret Cancer Centre, Toronto, ON, Canada; Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada.
| |
Collapse
|
10
|
Improvement of light penetration in biological tissue using an ultrasound-induced heating tunnel. Sci Rep 2020; 10:17406. [PMID: 33060643 PMCID: PMC7562700 DOI: 10.1038/s41598-020-73878-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Accepted: 09/21/2020] [Indexed: 02/07/2023] Open
Abstract
The major obstacles of optical imaging and photothermal therapy in biomedical applications is the strong scattering of light within biological tissues resulting in light defocusing and limited penetration. In this study, we propose high intensity focused ultrasound (HIFU)-induced heating tunnel to reduce the photon scattering. To verify our idea, Monte Carlo simulation and intralipid-phantom experiments were conducted. The results show that the thermal effect created by HIFU could improve the light fluence at the targeted region by 3% in both simulation and phantom experiments. Owing to the fluence increase, similar results can also be found in the photoacoustic experiments. In conclusion, our proposed method shows a noninvasive way to increase the light delivery efficiency in turbid medium. It is expected that our finding has a potential for improving the focal light delivery in photoacoustic imaging and photothermal therapy.
Collapse
|
11
|
Real-Time HIFU Treatment Monitoring Using Pulse Inversion Ultrasonic Imaging. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8112219] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Real-time monitoring of high-intensity focused ultrasound (HIFU) surgery is essential for safe and accurate treatment. However, ultrasound imaging is difficult to use for treatment monitoring during HIFU surgery because of the high intensity of the HIFU echoes that are received by an imaging transducer. Here, we propose a real-time HIFU treatment monitoring method based on pulse inversion of imaging ultrasound; an imaging transducer fires ultrasound twice in 0° and 180° phases for one scanline while HIFUs of the same phase are transmitted in synchronization with the ultrasound transmission for imaging. By doing so, HIFU interferences can be eliminated after subtracting the two sets of the signals received by the imaging transducer. This function was implemented in a commercial research ultrasound scanner, and its performance was evaluated using the excised bovine liver. The experimental results demonstrated that the proposed method allowed ultrasound images to clearly show the echogenicity change induced by HIFU in the excised bovine liver. Additionally, it was confirmed that the moving velocity of the organs in the abdomen due to respiration does not affect the performance of the proposed method. Based on the experimental results, we believe that the proposed method can be used for real-time HIFU surgery monitoring that is a pivotal function for maximized treatment efficacy.
Collapse
|
12
|
Jang J, Chang JH. Design and Fabrication of a Miniaturized Convex Array for Combined Ultrasound and Photoacoustic Imaging of the Prostate. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:2086-2096. [PMID: 30106721 DOI: 10.1109/tuffc.2018.2864664] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Although transrectal ultrasound (TRUS) imaging is widely used for screening and diagnosing prostate cancer, it is often not found on TRUS images, depending on its stage, size, and location. In addition, due to the weak echo signal and the low contrast of TRUS images, it is difficult to diagnose early-stage prostate cancers and distinguish malignant tumors from benign prostatic hyperplasia. For this reason, TRUS image-guided biopsy is mandatory to confirm the malignancy of the suspicious tumor, but the diagnostic accuracy of initial biopsy is only 20%-30%, so that the patients inevitably undergo repeated biopsies. TRUS-photoacoustic (TRUS-PA) imaging is one way to resolve those problems. However, the development of a TRUS-PA probe, in which an ultrasound array transducer and optical fibers are integrated, is demanding because the overall size of the probe should be as small as possible for the convenience of the patients, while providing the desired performances. Here, we report a recently developed TRUS-PA probe. The core element of the TRUS-PA is a miniaturized 128-element, 7-MHz convex array transducer of which size in the lateral and elevational directions is 11.4 and 5 mm, respectively. A new concept of a flexible printed circuit board was also developed to limit the size of the TRUS-PA probe to less than 15 mm. From the performance evaluation, it was found that the developed array with a field-of-view of 134° has a center frequency of 6.75 MHz, a -6-dB fractional bandwidth of 66%, and a crosstalk of less than -45 dB. In the tissue-mimicking phantom test and ex vivo experiments, the miniaturized convex array proved to be capable of providing combined US and PA images with acceptable imaging quality in spite of its small size.
Collapse
|
13
|
Kim H, Jo G, Chang JH. Ultrasound-assisted photothermal therapy and real-time treatment monitoring. BIOMEDICAL OPTICS EXPRESS 2018; 9:4472-4480. [PMID: 30615724 PMCID: PMC6157783 DOI: 10.1364/boe.9.004472] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Revised: 07/25/2018] [Accepted: 08/20/2018] [Indexed: 06/09/2023]
Abstract
Photothermal therapy (PTT) has the capability for selective treatment, in which light delivered to the target is converted into heat and subsequently causes coagulative necrosis. However, optical scattering in biological media limits light penetration, thus reducing therapeutic efficacy. Here, we demonstrate that the temperatures generated by light and ultrasound energies can be added constructively in resected melanoma cancers, which causes an increase in treatment depth. This method is called dual thermal therapy (DTT). It is also shown that combined ultrasound and photoacoustic images acquired using the pulse sequence proposed in this paper can be used for real-time monitoring of DTT.
Collapse
Affiliation(s)
- Haemin Kim
- Department of Biomedical Engineering, Sogang University, Seoul, 04107, South Korea
| | - Gyuwon Jo
- Department of Electronic Engineering, Sogang University, Seoul, 04107, South Korea
| | - Jin Ho Chang
- Department of Biomedical Engineering, Sogang University, Seoul, 04107, South Korea
- Department of Electronic Engineering, Sogang University, Seoul, 04107, South Korea
| |
Collapse
|
14
|
Kim H, Chang JH. Multimodal photoacoustic imaging as a tool for sentinel lymph node identification and biopsy guidance. Biomed Eng Lett 2018; 8:183-191. [PMID: 30603202 PMCID: PMC6208518 DOI: 10.1007/s13534-018-0068-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2018] [Revised: 04/14/2018] [Accepted: 04/15/2018] [Indexed: 02/06/2023] Open
Abstract
As a minimally invasive method, sentinel lymph node biopsy (SLNB) in conjunction with guidance methods is the standard method to determine cancer metastasis in breast. The desired guidance methods for SLNB should be capable of precise SLN localization for accurate diagnosis of micro-metastases at an early stage of cancer progression and thus facilitate reducing the number of SLN biopsies for minimal surgical complications. For this, high sensitivity to the administered dyes, high spatial and contrast resolutions, deep imaging depth, and real-time imaging capability are pivotal requirements. Currently, various methods have been used for SLNB guidance, each with their own advantages and disadvantages, but no methods meet the requirements. In this review, we discuss the conventional SLNB guidance methods in this perspective. In addition, we focus on the role of the PA imaging modality on real-time SLN identification and biopsy guidance. In particular, PA-based hybrid imaging methods for precise SLN identification and efficient biopsy guidance are introduced, and their unique features, advantages, and disadvantages are discussed.
Collapse
Affiliation(s)
- Haemin Kim
- Department of Biomedical Engineering, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul, 04107 South Korea
| | - Jin Ho Chang
- Department of Biomedical Engineering, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul, 04107 South Korea
- Department of Electronic Engineering, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul, 04107 South Korea
| |
Collapse
|