1
|
Gofin Y, Svirsky R, Lavi Ben Atav D, Liberman M, Tenne T, Perlman S, Sukenik-Halevy R. DNA concentrations in amniotic fluid according to gestational age and fetal sex: data from 2573 samples. Arch Gynecol Obstet 2024; 310:1981-1987. [PMID: 39210070 PMCID: PMC11393111 DOI: 10.1007/s00404-024-07698-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2024] [Accepted: 08/15/2024] [Indexed: 09/04/2024]
Abstract
PURPOSE In some cases of prenatal genetic testing, an ample amount of fetal DNA is needed, to allow for parallel testing (conducting several genetic tests simultaneously). This study investigated the association between amniotic fluid DNA concentration and various factors. We aimed to define the required amount of amniotic fluid to be extracted in amniocentesis, to allow parallel testing throughout gestational weeks. METHODS DNA concentration was analyzed from amniocentesis samples taken during the years 2016-2022. Sex association was also analyzed in postnatal whole blood samples from a separate cohort. Theoretical minimum volume of amniotic fluid needed to ensure enough DNA for chromosomal microarray analysis and exome sequencing was calculated. RESULTS We focused our analysis on 2573 samples, which were taken during weeks 17-23 and 30-35. DNA concentrations increased from weeks 17 to 21, with relatively stable concentrations thereafter. Significantly higher DNA concentrations were seen in pregnancies of female fetuses. DNA concentrations in postnatal whole blood samples did not show this association. Across most weeks, the volume needed to extract 2 µg of DNA from 95% of the samples was about 34 ml. CONCLUSION DNA concentrations in amniotic fluid vary according to gestational age and are higher in pregnancies of female fetuses. This should be considered when determining the volume of fluid extracted and the timing of amniocentesis, with greater volumes needed in earlier stages of pregnancy.
Collapse
Affiliation(s)
- Yoel Gofin
- Genetics Institute, Meir Medical Center, Kfar Saba, Israel.
- School of Medicine, Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, Israel.
| | - Ran Svirsky
- Genetic Unit, Department of Obstetrics and Gynecology, Samson Assuta Ashdod University Hospital, Ashdod, Israel
- Faculty of Health Sciences, Ben-Gurion University of the Negev, Be'er Sheva, Israel
| | | | | | - Tamar Tenne
- Genetics Institute, Meir Medical Center, Kfar Saba, Israel
| | - Sharon Perlman
- School of Medicine, Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, Israel
- Rabin Medical Center, Ultrasound Unit, Helen Schneider Women's Hospital, Petah Tikva, Israel
| | - Rivka Sukenik-Halevy
- Genetics Institute, Meir Medical Center, Kfar Saba, Israel
- School of Medicine, Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
2
|
Yılmaz Ergani S, Çakır BT, Akay A, Ulusoy CO, Akdaş Reis Y, Sarsmaz K, Örgül G, Esin S, Çağlar AT. Predicting the fetal weight by ultrasonography for isolated polyhydramnios: Comparison of 14 formulas. J Obstet Gynaecol Res 2024; 50:1522-1530. [PMID: 39054749 DOI: 10.1111/jog.16025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Accepted: 07/07/2024] [Indexed: 07/27/2024]
Abstract
OBJECTIVE To recalculate the estimated fetal weight (EFW) based on ultrasound measurements in patients complicated with isolated polyhydramnios, using 14 current formulas to observe which formula better predicts the EFW. METHODS This study examined pregnant women who gave birth in the hospital between January 2015 and January 2020. Maximum vertical pocket (MVP) was classified as, mild, moderate, and severe polyhydramnios, and the patients' measurements were reanalyzed using 14 formulas. The estimation of birth weight (EBW) alongside observed birth weight (OBW) facilitated the computation of statistical indices, namely the mean absolute percentage error (MAPE) expressed as [(EBW - OBW)/OBW × 100], the mean percentage error (MPE) denoted as (EBW - OBW)/(OBW × 100), and their corresponding 95% confidence intervals. RESULTS A total of 564 polyhydramnios patients were included in the study. When looking at the MAPE, the lowest rate (7.65) was found in the Hadlock 2 formula. Hadlock 1, Hadlock 3, and Shinozuka formulas demonstrated MAPE values most closely aligned with Hadlock 2. Weiner I and Thurnau were the formulas with the highest MAPE values. When the cut-off values for MAPE were taken as 10%, 4/14 of the formulas (Weiner I-II, Vintzleos and Thurnau) gave results above 10%. Among 14 formulas, 3 (21.4%) had positive (sonographic overestimation) (Hadlock 3, Shinozuka, and Vintzleos) and the other 11 (78.6%) had negative MPE (sonographic underestimation). CONCLUSION The Hadlock 2 formula had the lowest MAPE in predicting birth weight in patients with polyhydramnios, closely followed by the Hadlock 1, Hadlock 3, and Shinozuka formulas.
Collapse
Affiliation(s)
- Seval Yılmaz Ergani
- Department of Perinatology, Etlik Zubeyde Hanım Women's Health Training and Research Hospital, Ankara, Turkey
| | - Betül Tokgöz Çakır
- Department of Perinatology, Etlik Zubeyde Hanım Women's Health Training and Research Hospital, Ankara, Turkey
| | - Arife Akay
- Department of Obstetrics and Gynecology, Etlik Zubeyde Hanım Women's Health Training and Research Hospital, Ankara, Turkey
| | - Can Ozan Ulusoy
- Department of Perinatology, Etlik Zubeyde Hanım Women's Health Training and Research Hospital, Ankara, Turkey
| | - Yıldız Akdaş Reis
- Department of Obstetrics and Gynecology, Etlik Zubeyde Hanım Women's Health Training and Research Hospital, Ankara, Turkey
| | - Kemal Sarsmaz
- Department of Perinatology, Etlik Zubeyde Hanım Women's Health Training and Research Hospital, Ankara, Turkey
| | - Gökçen Örgül
- Department of Perinatology, Etlik Zubeyde Hanım Women's Health Training and Research Hospital, Ankara, Turkey
| | - Sertaç Esin
- Department of Perinatology, Etlik Zubeyde Hanım Women's Health Training and Research Hospital, Ankara, Turkey
| | - Ali Turhan Çağlar
- Department of Perinatology, Etlik Zubeyde Hanım Women's Health Training and Research Hospital, Ankara, Turkey
| |
Collapse
|
3
|
Souza SCS, Kim K, Dingwall-Harvey ALJ, Fakhraei R, Liao Y, Gaudet LM. Evaluating the correlation between amniotic fluid volume and estimated fetal weight in healthy pregnant women. J Perinat Med 2022; 50:1096-1099. [PMID: 35589556 DOI: 10.1515/jpm-2022-0104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 04/25/2022] [Indexed: 11/15/2022]
Abstract
OBJECTIVES The establishment of cut-offs for normal amniotic fluid volume (AFV) is valuable to predict perinatal outcomes. However, the most common methods to measure AFV are not accurate enough. It is important to understand factors that may be able to increase the accuracy of the calculation of AFV cut-off values. The objective of this study was to verify the correlation between AFV and estimated fetal weight (EFW). METHODS Records from almost 7,000 patients between 2012 and 2017 were accessed through hospital databases. The AFV measurements included in our analysis were obtained using the maximum vertical pocket technique. RESULTS AFV was positively correlated with EFW in the overall, male and female samples; however, the magnitude of the association was small (0.1 CONCLUSIONS The incorporation of EFW together with other factors (e.g., gestational age, fetus sex) may increase the accuracy of the AFV cut-offs calculation and, ultimately, reduce morbidity.
Collapse
Affiliation(s)
- Sara C S Souza
- OMNI Research Group, Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, Canada
| | - Katherine Kim
- OMNI Research Group, Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, Canada
| | | | - Romina Fakhraei
- OMNI Research Group, Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, Canada
- School of Epidemiology and Public Health, University of Ottawa, Ottawa, Canada
| | - Yan Liao
- OMNI Research Group, Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, Canada
| | - Laura M Gaudet
- OMNI Research Group, Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, Canada
- School of Epidemiology and Public Health, University of Ottawa, Ottawa, Canada
- Department of Obstetrics and Gynecology, Kingston Health Sciences Center, Kingston, Canada
- Department of Obstetrics and Gynecology, Queen's University, Kingston, Canada
| |
Collapse
|
4
|
Correlation between newborn size and gross fetal movement as counted by a fetal movement acceleration measurement recorder. J Dev Orig Health Dis 2020; 12:452-455. [PMID: 32662381 DOI: 10.1017/s2040174420000641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The development of the fetal movement acceleration measurement (FMAM) recorder has enabled the accurate counting of gross fetal movements. The aim of the study was to investigate whether gross fetal movement is related to a newborn's size. A total of 90 pregnant women who delivered singleton infant at term were recruited. Gross fetal movements were counted using an FMAM recorder during maternal sleep. The ratio of movement positive 10-s epochs to all epochs during one night was calculated as an index of fetal movement. Independent explanatory variables for the fetal movement index were selected from eight possibilities, that is, maternal age, gestational week, and the six physical measures of the newborn (height, weight, head circumference, chest circumference, Kaup index, and the ratio of head to chest circumference) with the stepwise regression procedure. The selected physical variables and the fetal movement index were analyzed using multiple regression analysis. A total of 2812.95 h from 423 night records were available. Gestational weeks and weight of the newborn were selected as the significant independent variables. Multiple regression analysis revealed that newborn weight had a positive correlation with the fetal movement index (p < 0.0001). The multiple regression equation was "The fetal movement index (%) = 34.9989-0.9088 × gestational weeks + 0.0033 × newborn weight (g)." A person's physical ability and lifetime activity level may originate from fetal health. This study may provide a new way of looking at the Developmental Origins of Health and Disease theory.
Collapse
|
5
|
Eroglu H, Orgul G, Avcı E, Altınboga O, Karakoc G, Yucel A. Comparison of automated vs. manual measurement to estimate fetal weight in isolated polyhydramnios. J Perinat Med 2019; 47:592-597. [PMID: 31141491 DOI: 10.1515/jpm-2019-0083] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Accepted: 04/22/2019] [Indexed: 01/24/2023]
Abstract
Objective To understand the impact of the measurement method to predict actual birthweight in pregnancies complicated with isolated polyhydramnios in the third trimester. Methods A prospective study was conducted with 60 pregnant women between the 37th and 40th weeks of gestation. Routine biometric measurements were obtained by two-dimensional (2D) ultrasonography. When a satisfactory image was obtained, the image was frozen to get two measurements. First, calipers were placed to get the manual measurement. Then automated measurement was captured by the ultrasonography machine in the same image. The fetal weight was estimated by using the Hadlock II formula. Results The mean difference was found to be 0.03, -0.77, -0.02 and 0.17 for biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC) and femur length (FL), respectively. Pearson's correlation coefficient between automated and manual estimated fetal weights (EFWs) and the actual birthweight was 0.919 and 0.796, respectively. The mean difference between actual and manual EFW measurement values was 46.16 ± 363.81 g (range between -745 g and 685 g) (P = 0.330). Also, the mean difference between actual and automated EFW measurement values was found to be 31.98 ± 218.65 g (range between -378 g and 742 g) (P = 0.262). The Bland-Altman test results have shown that, 666 g lower or 759 g higher values were obtained when the measurement was performed manually. On the other hand, EFW results were 396 g lower or 460 g higher than the actual birthweight with automated measurement tools. Conclusion The accuracy rate of fetal weight estimation with ultrasonography is high for both automated and manual measurements. Automated tools have a higher success to predict the EFW.
Collapse
Affiliation(s)
- Hasan Eroglu
- Department of Perinatology, Etlik Zubeyde Hanim Women's Health Care, Training and Research Hospital, University of Health Sciences, Ankara, Turkey
| | - Gokcen Orgul
- Department of Perinatology, Etlik Zubeyde Hanim Women's Health Care, Training and Research Hospital, University of Health Sciences, Ankara, Turkey
| | - Emine Avcı
- Department of Communicable Diseases, General Directorate of Public Health, Ankara, Turkey
| | - Orhan Altınboga
- Department of Perinatology, Etlik Zubeyde Hanim Women's Health Care, Training and Research Hospital, University of Health Sciences, Ankara, Turkey
| | - Gokhan Karakoc
- Department of Perinatology, Etlik Zubeyde Hanim Women's Health Care, Training and Research Hospital, University of Health Sciences, Ankara, Turkey
| | - Aykan Yucel
- Department of Perinatology, Etlik Zubeyde Hanim Women's Health Care, Training and Research Hospital, University of Health Sciences, Ankara, Turkey
| |
Collapse
|