Torres-Castro K, Acuña-Umaña K, Lesser-Rojas L, Reyes DR. Microfluidic Blood Separation: Key Technologies and Critical Figures of Merit. MICROMACHINES 2023; 14:2117. [PMID: 38004974 PMCID: PMC10672873 DOI: 10.3390/mi14112117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 11/01/2023] [Accepted: 11/10/2023] [Indexed: 11/26/2023]
Abstract
Blood is a complex sample comprised mostly of plasma, red blood cells (RBCs), and other cells whose concentrations correlate to physiological or pathological health conditions. There are also many blood-circulating biomarkers, such as circulating tumor cells (CTCs) and various pathogens, that can be used as measurands to diagnose certain diseases. Microfluidic devices are attractive analytical tools for separating blood components in point-of-care (POC) applications. These platforms have the potential advantage of, among other features, being compact and portable. These features can eventually be exploited in clinics and rapid tests performed in households and low-income scenarios. Microfluidic systems have the added benefit of only needing small volumes of blood drawn from patients (from nanoliters to milliliters) while integrating (within the devices) the steps required before detecting analytes. Hence, these systems will reduce the associated costs of purifying blood components of interest (e.g., specific groups of cells or blood biomarkers) for studying and quantifying collected blood fractions. The microfluidic blood separation field has grown since the 2000s, and important advances have been reported in the last few years. Nonetheless, real POC microfluidic blood separation platforms are still elusive. A widespread consensus on what key figures of merit should be reported to assess the quality and yield of these platforms has not been achieved. Knowing what parameters should be reported for microfluidic blood separations will help achieve that consensus and establish a clear road map to promote further commercialization of these devices and attain real POC applications. This review provides an overview of the separation techniques currently used to separate blood components for higher throughput separations (number of cells or particles per minute). We present a summary of the critical parameters that should be considered when designing such devices and the figures of merit that should be explicitly reported when presenting a device's separation capabilities. Ultimately, reporting the relevant figures of merit will benefit this growing community and help pave the road toward commercialization of these microfluidic systems.
Collapse
Affiliation(s)
- Karina Torres-Castro
- Biophysical and Biomedical Measurements Group, National Institute of Standards and Technology (NIST), 100 Bureau Drive, Gaithersburg, MD 20899, USA;
- Theiss Research, La Jolla, CA 92037, USA
| | - Katherine Acuña-Umaña
- Medical Devices Master’s Program, Instituto Tecnológico de Costa Rica (ITCR), Cartago 30101, Costa Rica
| | - Leonardo Lesser-Rojas
- Research Center in Atomic, Nuclear and Molecular Sciences (CICANUM), San José 11501, Costa Rica;
- School of Physics, Universidad de Costa Rica (UCR), San José 11501, Costa Rica
| | - Darwin R. Reyes
- Biophysical and Biomedical Measurements Group, National Institute of Standards and Technology (NIST), 100 Bureau Drive, Gaithersburg, MD 20899, USA;
| |
Collapse
|
2
|
Dang Z, Jiang Y, Su X, Wang Z, Wang Y, Sun Z, Zhao Z, Zhang C, Hong Y, Liu Z. Particle Counting Methods Based on Microfluidic Devices. MICROMACHINES 2023; 14:1722. [PMID: 37763885 PMCID: PMC10534595 DOI: 10.3390/mi14091722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Revised: 08/30/2023] [Accepted: 08/30/2023] [Indexed: 09/29/2023]
Abstract
Particle counting serves as a pivotal constituent in diverse analytical domains, encompassing a broad spectrum of entities, ranging from blood cells and bacteria to viruses, droplets, bubbles, wear debris, and magnetic beads. Recent epochs have witnessed remarkable progressions in microfluidic chip technology, culminating in the proliferation and maturation of microfluidic chip-based particle counting methodologies. This paper undertakes a taxonomical elucidation of microfluidic chip-based particle counters based on the physical parameters they detect. These particle counters are classified into three categories: optical-based counters, electrical-based particle counters, and other counters. Within each category, subcategories are established to consider structural differences. Each type of counter is described not only in terms of its working principle but also the methods employed to enhance sensitivity and throughput. Additionally, an analysis of future trends related to each counter type is provided.
Collapse
Affiliation(s)
- Zenglin Dang
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| | - Yuning Jiang
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| | - Xin Su
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| | - Zhihao Wang
- College of Marine Electrical Engineering, Dalian Maritime University, Dalian 116026, China;
| | - Yucheng Wang
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| | - Zhe Sun
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| | - Zheng Zhao
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| | - Chi Zhang
- College of Transportation Engineering, Dalian Maritime University, Dalian 116026, China;
| | - Yuming Hong
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| | - Zhijian Liu
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| |
Collapse
|
3
|
Recent advances in non-optical microfluidic platforms for bioparticle detection. Biosens Bioelectron 2023; 222:114944. [PMID: 36470061 DOI: 10.1016/j.bios.2022.114944] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 11/17/2022] [Accepted: 11/22/2022] [Indexed: 12/03/2022]
Abstract
The effective analysis of the basic structure and functional information of bioparticles are of great significance for the early diagnosis of diseases. The synergism between microfluidics and particle manipulation/detection technologies offers enhanced system integration capability and test accuracy for the detection of various bioparticles. Most microfluidic detection platforms are based on optical strategies such as fluorescence, absorbance, and image recognition. Although optical microfluidic platforms have proven their capabilities in the practical clinical detection of bioparticles, shortcomings such as expensive components and whole bulky devices have limited their practicality in the development of point-of-care testing (POCT) systems to be used in remote and underdeveloped areas. Therefore, there is an urgent need to develop cost-effective non-optical microfluidic platforms for bioparticle detection that can act as alternatives to optical counterparts. In this review, we first briefly summarise passive and active methods for bioparticle manipulation in microfluidics. Then, we survey the latest progress in non-optical microfluidic strategies based on electrical, magnetic, and acoustic techniques for bioparticle detection. Finally, a perspective is offered, clarifying challenges faced by current non-optical platforms in developing practical POCT devices and clinical applications.
Collapse
|
4
|
Grigorev GV, Lebedev AV, Wang X, Qian X, Maksimov GV, Lin L. Advances in Microfluidics for Single Red Blood Cell Analysis. BIOSENSORS 2023; 13:117. [PMID: 36671952 PMCID: PMC9856164 DOI: 10.3390/bios13010117] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/04/2022] [Accepted: 12/23/2022] [Indexed: 05/24/2023]
Abstract
The utilizations of microfluidic chips for single RBC (red blood cell) studies have attracted great interests in recent years to filter, trap, analyze, and release single erythrocytes for various applications. Researchers in this field have highlighted the vast potential in developing micro devices for industrial and academia usages, including lab-on-a-chip and organ-on-a-chip systems. This article critically reviews the current state-of-the-art and recent advances of microfluidics for single RBC analyses, including integrated sensors and microfluidic platforms for microscopic/tomographic/spectroscopic single RBC analyses, trapping arrays (including bifurcating channels), dielectrophoretic and agglutination/aggregation studies, as well as clinical implications covering cancer, sepsis, prenatal, and Sickle Cell diseases. Microfluidics based RBC microarrays, sorting/counting and trapping techniques (including acoustic, dielectrophoretic, hydrodynamic, magnetic, and optical techniques) are also reviewed. Lastly, organs on chips, multi-organ chips, and drug discovery involving single RBC are described. The limitations and drawbacks of each technology are addressed and future prospects are discussed.
Collapse
Affiliation(s)
- Georgii V. Grigorev
- Data Science and Information Technology Research Center, Tsinghua Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518055, China
- Mechanical Engineering Department, University of California in Berkeley, Berkeley, CA 94720, USA
- School of Information Technology, Cherepovets State University, 162600 Cherepovets, Russia
| | - Alexander V. Lebedev
- Machine Building Department, Bauman Moscow State University, 105005 Moscow, Russia
| | - Xiaohao Wang
- Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - Xiang Qian
- Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - George V. Maksimov
- Faculty of Biology, Lomonosov Moscow State University, 119991 Moscow, Russia
- Physical metallurgy Department, Federal State Autonomous Educational Institution of Higher Education National Research Technological University “MISiS”, 119049 Moscow, Russia
| | - Liwei Lin
- Mechanical Engineering Department, University of California in Berkeley, Berkeley, CA 94720, USA
| |
Collapse
|
5
|
Kim H, Zhbanov A, Yang S. Microfluidic Systems for Blood and Blood Cell Characterization. BIOSENSORS 2022; 13:13. [PMID: 36671848 PMCID: PMC9856090 DOI: 10.3390/bios13010013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 12/16/2022] [Accepted: 12/19/2022] [Indexed: 06/17/2023]
Abstract
A laboratory blood test is vital for assessing a patient's health and disease status. Advances in microfluidic technology have opened the door for on-chip blood analysis. Currently, microfluidic devices can reproduce myriad routine laboratory blood tests. Considerable progress has been made in microfluidic cytometry, blood cell separation, and characterization. Along with the usual clinical parameters, microfluidics makes it possible to determine the physical properties of blood and blood cells. We review recent advances in microfluidic systems for measuring the physical properties and biophysical characteristics of blood and blood cells. Added emphasis is placed on multifunctional platforms that combine several microfluidic technologies for effective cell characterization. The combination of hydrodynamic, optical, electromagnetic, and/or acoustic methods in a microfluidic device facilitates the precise determination of various physical properties of blood and blood cells. We analyzed the physical quantities that are measured by microfluidic devices and the parameters that are determined through these measurements. We discuss unexplored problems and present our perspectives on the long-term challenges and trends associated with the application of microfluidics in clinical laboratories. We expect the characterization of the physical properties of blood and blood cells in a microfluidic environment to be considered a standard blood test in the future.
Collapse
Affiliation(s)
- Hojin Kim
- Department of Mechatronics Engineering, Dongseo University, Busan 47011, Republic of Korea
| | - Alexander Zhbanov
- School of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea
| | - Sung Yang
- School of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea
- Department of Biomedical Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea
| |
Collapse
|
6
|
Ashley BK, Hassan U. Digital filtering dissemination for optimizing impedance cytometry signal quality and counting accuracy. Biomed Microdevices 2022; 24:36. [PMID: 36305954 PMCID: PMC9635870 DOI: 10.1007/s10544-022-00636-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/04/2022] [Indexed: 11/29/2022]
Abstract
Improving biosensor performance which utilize impedance cytometry is a highly interested research topic for many clinical and diagnostic settings. During development, a sensor's design and external factors are rigorously optimized, but improvements in signal quality and interpretation are usually still necessary to produce a sensitive and accurate product. A common solution involves digital signal processing after sample analysis, but these methods frequently fall short in providing meaningful signal outcome changes. This shortcoming may arise from a lack of investigative research into selecting and using signal processing functions, as many choices in current sensors are based on either theoretical results or estimated hypotheses. While a ubiquitous condition set is improbable across diverse impedance cytometry designs, there lies a need for a streamlined and rapid analytical method for discovering those conditions for unique sensors. Herein, we present a comprehensive dissemination of digital filtering parameters applied on experimental impedance cytometry data for determining the limits of signal processing on signal quality improvements. Various filter orders, cutoff frequencies, and filter types are applied after data collection for highest achievable noise reduction. After designing and fabricating a microfluidic impedance cytometer, 9 µm polystyrene particles were measured under flow and signal quality improved by 6.09 dB when implementing digital filtering. This approached was then translated to isolated human neutrophils, where similarly, signal quality improved by 7.50 dB compared to its unfiltered original data. By sweeping all filtering conditions and devising a system to evaluate filtering performance both by signal quality and object counting accuracy, this may serve as a framework for future systems to determine their appropriately optimized filtering configuration.
Collapse
Affiliation(s)
- Brandon K Ashley
- Department of Biomedical Engineering, Rutgers, the State University of New Jersey, Piscataway, NJ, 08854, USA
| | - Umer Hassan
- Department of Electrical Engineering, Department of Biomedical Engineering, and Global Health Institute Rutgers, the State University of New Jersey, Piscataway, NJ, 08854, USA.
| |
Collapse
|
7
|
Sun A, Ji Y, Li Y, Xie W, Liu Z, Li T, Jin T, Qi W, Li K, Wu C, Xi L. Multicolor Photoacoustic Volumetric Imaging of Subcellular Structures. ACS NANO 2022; 16:3231-3238. [PMID: 35080378 DOI: 10.1021/acsnano.1c11103] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Photoacoustic imaging (PAI) has been widely used in multiscale and multicontrast imaging of biological structures and functions. Optical resolution photoacoustic microscopy (OR-PAM), an emerging submodality of PAI, features high lateral resolution and rich optical contrast, indicating great potential in visualizing cellular and subcellular structures. However, three-dimensional (3D) imaging of subcellular structures using OR-PAM has remained a challenge due to the limited axial resolution. In this study, we propose a multicolor 3D photoacoustic microscopy with high lateral/axial resolutions of 0.42/2 and 0.5/2.5 μm at 532 and 780 nm excitation, respectively. Owing to the significantly increased axial resolution, we could visualize the volumetric subcellular structures of melanoma cells using intrinsic contrast. In addition, we carried out multicolor imaging of labeled microtubules/clathrin-coated pits (CCP) and microtubules/mitochondria, respectively, with one scanning by using two different excitation wavelengths. The internal connections between different subcellular structures are revealed by quantitatively comparing the spatial distributions of microtubules/CCP and microtubules/mitochondria in a single cell. Current results suggest that the proposed OR-PAM may serve as an efficient tool for subcellular and cytophysiological studies.
Collapse
Affiliation(s)
- Aihui Sun
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| | - Yaoyao Ji
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| | - Yaxi Li
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| | - Wenhui Xie
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| | - Zhihe Liu
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| | - Tingting Li
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| | - Tian Jin
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| | - Weizhi Qi
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, China
- Shenzhen Bay Laboratory, Shenzhen 518132, China
| | - Kai Li
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| | - Changfeng Wu
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| | - Lei Xi
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| |
Collapse
|
8
|
Teixeira A, Carneiro A, Piairo P, Xavier M, Ainla A, Lopes C, Sousa-Silva M, Dias A, Martins AS, Rodrigues C, Pereira R, Pires LR, Abalde-Cela S, Diéguez L. Advances in Microfluidics for the Implementation of Liquid Biopsy in Clinical Routine. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1379:553-590. [DOI: 10.1007/978-3-031-04039-9_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
9
|
Sun A, Li T, Jin T, Li Y, Li K, Song C, Xi L. Acoustic Standing Wave Aided Multiparametric Photoacoustic Imaging Flow Cytometry. Anal Chem 2021; 93:14820-14827. [PMID: 34714062 DOI: 10.1021/acs.analchem.1c03713] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Photoacoustic imaging reveals great potential for the study of individual cells due to the rich imaging contrast for both label-free and labeled cells. However, previously reported photoacoustic imaging flow cytometry configuration suffers from inadequate imaging quality and challenge to distinguish multiple cells. In order to solve such issues, we propose a novel acoustic standing wave aided multiparametric photoacoustic imaging flow cytometry (MPAFC) system. The acoustic standing wave is introduced to improve the imaging quality and speed. Multispectral illumination along with cell geometry, photoacoustic amplitude, and acoustic frequency spectrum enables the proposed system to precisely identify multiple types of cells with one scanning. On the basis of the identification, elimination of melanoma cells, and targeted labeled glioma cells have been performed with an elimination efficiency of >95%. Additionally, the MPAFC system is able to image and capture melanoma cells at a lowest concentration of 100 cells mL-1 in pure blood. Current results suggest that the proposed MPAFC may provide a precise and efficient tool for cell detection, manipulation, and elimination in both fundamental and clinical studies.
Collapse
Affiliation(s)
- Aihui Sun
- Harbin Institute of Technology, Harbin 150001, P. R. China.,Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, P. R. China
| | - Tingting Li
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, P. R. China
| | - Tian Jin
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, P. R. China
| | - Yaxi Li
- Harbin Institute of Technology, Harbin 150001, P. R. China.,Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, P. R. China
| | - Kai Li
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, P. R. China
| | - Chaolong Song
- School of Mechanical Engineering and Electronic Information, China University of Geosciences, Wuhan, 430074, P. R. China
| | - Lei Xi
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, P. R. China
| |
Collapse
|
10
|
Zhao W, Yu H, Wen Y, Luo H, Jia B, Wang X, Liu L, Li WJ. Real-time red blood cell counting and osmolarity analysis using a photoacoustic-based microfluidic system. LAB ON A CHIP 2021; 21:2586-2593. [PMID: 34008680 DOI: 10.1039/d1lc00263e] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Counting the number of red blood cells (RBCs) in blood samples is a common clinical diagnostic procedure, but conventional methods are unable to provide the size and other physical properties of RBCs at the same time. In this work, we explore photoacoustic (PA) detection as a rapid label-free and noninvasive analysis technique that can potentially be used for single RBC characterization based on their photoabsorption properties. We have demonstrated an on-chip PA flow cytometry system using a simple microfluidic chip combined with a PA imaging system to count and characterize up to ∼60 RBCs per second. Compared with existing microfluidic-based RBC analysis methods, which typically use camera-captured image sequences to characterize cell morphology and deformation, the PA method discussed here requires only the processing of one-dimensional time-series data instead of two- or three-dimensional time-series data acquired by computer vision methods. Therefore, the PA method will have significantly lower computational requirements when large numbers of RBCs are to be analyzed. Moreover, we have demonstrated that the PA signals of RBCs flowing in a microfluidic device could be directly used to acquire the osmolarity conditions (in the range of 124 to 497 mOsm L-1) of the medium surrounding the RBCs. This finding suggests a potential extension of applicability to blood tests via PA-based biomedical detection.
Collapse
Affiliation(s)
- Wenxiu Zhao
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China. and Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China and University of Chinese Academy of Sciences, Beijing 100049, China
| | - Haibo Yu
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China. and Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China
| | - Yangdong Wen
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China. and Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China and University of Chinese Academy of Sciences, Beijing 100049, China
| | - Hao Luo
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China. and Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China and University of Chinese Academy of Sciences, Beijing 100049, China
| | - Boliang Jia
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, SAR, China.
| | - Xiaoduo Wang
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China. and Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China
| | - Lianqing Liu
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China. and Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China
| | - Wen Jung Li
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China. and Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China and Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, SAR, China.
| |
Collapse
|
11
|
Blevins MG, Allen HL, Colson BC, Cook AM, Greenbaum AZ, Hemami SS, Hollmann J, Kim E, LaRocca AA, Markoski KA, Miraglia P, Mott VL, Robberson WM, Santos JA, Sprachman MM, Swierk P, Tate S, Witinski MF, Kratchman LB, Michel APM. Field-Portable Microplastic Sensing in Aqueous Environments: A Perspective on Emerging Techniques. SENSORS (BASEL, SWITZERLAND) 2021; 21:3532. [PMID: 34069517 PMCID: PMC8160859 DOI: 10.3390/s21103532] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 04/27/2021] [Accepted: 04/28/2021] [Indexed: 11/28/2022]
Abstract
Microplastics (MPs) have been found in aqueous environments ranging from rural ponds and lakes to the deep ocean. Despite the ubiquity of MPs, our ability to characterize MPs in the environment is limited by the lack of technologies for rapidly and accurately identifying and quantifying MPs. Although standards exist for MP sample collection and preparation, methods of MP analysis vary considerably and produce data with a broad range of data content and quality. The need for extensive analysis-specific sample preparation in current technology approaches has hindered the emergence of a single technique which can operate on aqueous samples in the field, rather than on dried laboratory preparations. In this perspective, we consider MP measurement technologies with a focus on both their eventual field-deployability and their respective data products (e.g., MP particle count, size, and/or polymer type). We present preliminary demonstrations of several prospective MP measurement techniques, with an eye towards developing a solution or solutions that can transition from the laboratory to the field. Specifically, experimental results are presented from multiple prototype systems that measure various physical properties of MPs: pyrolysis-differential mobility spectroscopy, short-wave infrared imaging, aqueous Nile Red labeling and counting, acoustophoresis, ultrasound, impedance spectroscopy, and dielectrophoresis.
Collapse
Affiliation(s)
- Morgan G. Blevins
- MIT-WHOI Joint Program in Oceanography/Applied Ocean Science & Engineering, Cambridge and Woods Hole, MA 02543, USA; (M.G.B.); (B.C.C.)
- Department of Applied Ocean Physics and Engineering, Woods Hole Oceanographic Institution, Woods Hole, MA 02543, USA
- Department of Aeronautics and Astronautics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- The Charles Stark Draper Laboratory Inc., Cambridge, MA 02139, USA; (A.Z.G.); (J.H.); (E.K.); (A.A.L.); (K.A.M.); (P.M.); (J.A.S.); (M.M.S.); (P.S.); (S.T.); (M.F.W.)
| | - Harry L. Allen
- Emergency Response Office, Superfund Division, U.S. EPA Region 9, San Francisco, CA 94105, USA;
| | - Beckett C. Colson
- MIT-WHOI Joint Program in Oceanography/Applied Ocean Science & Engineering, Cambridge and Woods Hole, MA 02543, USA; (M.G.B.); (B.C.C.)
- Department of Applied Ocean Physics and Engineering, Woods Hole Oceanographic Institution, Woods Hole, MA 02543, USA
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Anna-Marie Cook
- Kamilo, Inc., Former U.S. EPA Region 9, San Francisco, CA 94108, USA;
| | - Alexandra Z. Greenbaum
- The Charles Stark Draper Laboratory Inc., Cambridge, MA 02139, USA; (A.Z.G.); (J.H.); (E.K.); (A.A.L.); (K.A.M.); (P.M.); (J.A.S.); (M.M.S.); (P.S.); (S.T.); (M.F.W.)
| | - Sheila S. Hemami
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA 02115, USA;
| | - Joseph Hollmann
- The Charles Stark Draper Laboratory Inc., Cambridge, MA 02139, USA; (A.Z.G.); (J.H.); (E.K.); (A.A.L.); (K.A.M.); (P.M.); (J.A.S.); (M.M.S.); (P.S.); (S.T.); (M.F.W.)
| | - Ernest Kim
- The Charles Stark Draper Laboratory Inc., Cambridge, MA 02139, USA; (A.Z.G.); (J.H.); (E.K.); (A.A.L.); (K.A.M.); (P.M.); (J.A.S.); (M.M.S.); (P.S.); (S.T.); (M.F.W.)
| | - Ava A. LaRocca
- The Charles Stark Draper Laboratory Inc., Cambridge, MA 02139, USA; (A.Z.G.); (J.H.); (E.K.); (A.A.L.); (K.A.M.); (P.M.); (J.A.S.); (M.M.S.); (P.S.); (S.T.); (M.F.W.)
| | - Kenneth A. Markoski
- The Charles Stark Draper Laboratory Inc., Cambridge, MA 02139, USA; (A.Z.G.); (J.H.); (E.K.); (A.A.L.); (K.A.M.); (P.M.); (J.A.S.); (M.M.S.); (P.S.); (S.T.); (M.F.W.)
| | - Peter Miraglia
- The Charles Stark Draper Laboratory Inc., Cambridge, MA 02139, USA; (A.Z.G.); (J.H.); (E.K.); (A.A.L.); (K.A.M.); (P.M.); (J.A.S.); (M.M.S.); (P.S.); (S.T.); (M.F.W.)
| | - Vienna L. Mott
- Draper, Bioengineering Division, Cambridge, MA 02139, USA;
| | | | - Jose A. Santos
- The Charles Stark Draper Laboratory Inc., Cambridge, MA 02139, USA; (A.Z.G.); (J.H.); (E.K.); (A.A.L.); (K.A.M.); (P.M.); (J.A.S.); (M.M.S.); (P.S.); (S.T.); (M.F.W.)
| | - Melissa M. Sprachman
- The Charles Stark Draper Laboratory Inc., Cambridge, MA 02139, USA; (A.Z.G.); (J.H.); (E.K.); (A.A.L.); (K.A.M.); (P.M.); (J.A.S.); (M.M.S.); (P.S.); (S.T.); (M.F.W.)
| | - Patricia Swierk
- The Charles Stark Draper Laboratory Inc., Cambridge, MA 02139, USA; (A.Z.G.); (J.H.); (E.K.); (A.A.L.); (K.A.M.); (P.M.); (J.A.S.); (M.M.S.); (P.S.); (S.T.); (M.F.W.)
| | - Steven Tate
- The Charles Stark Draper Laboratory Inc., Cambridge, MA 02139, USA; (A.Z.G.); (J.H.); (E.K.); (A.A.L.); (K.A.M.); (P.M.); (J.A.S.); (M.M.S.); (P.S.); (S.T.); (M.F.W.)
| | - Mark F. Witinski
- The Charles Stark Draper Laboratory Inc., Cambridge, MA 02139, USA; (A.Z.G.); (J.H.); (E.K.); (A.A.L.); (K.A.M.); (P.M.); (J.A.S.); (M.M.S.); (P.S.); (S.T.); (M.F.W.)
| | - Louis B. Kratchman
- The Charles Stark Draper Laboratory Inc., Cambridge, MA 02139, USA; (A.Z.G.); (J.H.); (E.K.); (A.A.L.); (K.A.M.); (P.M.); (J.A.S.); (M.M.S.); (P.S.); (S.T.); (M.F.W.)
| | - Anna P. M. Michel
- Department of Applied Ocean Physics and Engineering, Woods Hole Oceanographic Institution, Woods Hole, MA 02543, USA
| |
Collapse
|
12
|
Seeger M, Stiel AC, Ntziachristos V. In vitro optoacoustic flow cytometry with light scattering referencing. Sci Rep 2021; 11:2181. [PMID: 33500461 PMCID: PMC7838204 DOI: 10.1038/s41598-021-81584-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Accepted: 01/08/2021] [Indexed: 11/09/2022] Open
Abstract
Morphological and functional optoacoustic imaging is enhanced by dedicated transgene reporters, in analogy to fluorescence methods. The development of optoacoustic reporters using protein engineering and directed evolution would be accelerated by high-throughput in-flow screening for intracellular, genetically encoded, optoacoustic contrast. However, accurate characterization of such contrast is impeded because the optoacoustic signals depend on the cell's size and position in the flow chamber. We report herein an optoacoustic flow cytometer (OA-FCM) capable of precise measurement of intracellular optoacoustic signals of genetically-encoded chromoproteins in flow. The novel system records light-scattering as a reference for the detected optoacoustic signals in order to account for cell size and position, as well as excitation light flux in the focal volume, which we use to reference the detected optoacoustic signals to enhance the system's precision. The OA-FCM was calibrated using micrometer-sized particles to showcase the ability to assess in-flow objects in the size range of single-cells. We demonstrate the capabilities of our OA-FCM to identify sub-populations in a mixture of two E. coli stocks expressing different reporter-proteins with a precision of over 90%. High-throughput screening of optoacoustic labels could pave the way for identifying genetically encoded optoacoustic reporters by transferring working concepts of the fluorescence field such as directed evolution and activated cell sorting.
Collapse
Affiliation(s)
- Markus Seeger
- Chair of Biological Imaging (CBI) and Center for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
- Institute of Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Neuherberg, Germany
| | - Andre C Stiel
- Institute of Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Neuherberg, Germany.
| | - Vasilis Ntziachristos
- Chair of Biological Imaging (CBI) and Center for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany.
- Institute of Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Neuherberg, Germany.
| |
Collapse
|
13
|
Das D, Sharma A, Rajendran P, Pramanik M. Another decade of photoacoustic imaging. Phys Med Biol 2020; 66. [PMID: 33361580 DOI: 10.1088/1361-6560/abd669] [Citation(s) in RCA: 52] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Accepted: 12/23/2020] [Indexed: 01/09/2023]
Abstract
Photoacoustic imaging - a hybrid biomedical imaging modality finding its way to clinical practices. Although the photoacoustic phenomenon was known more than a century back, only in the last two decades it has been widely researched and used for biomedical imaging applications. In this review we focus on the development and progress of the technology in the last decade (2010-2020). From becoming more and more user friendly, cheaper in cost, portable in size, photoacoustic imaging promises a wide range of applications, if translated to clinic. The growth of photoacoustic community is steady, and with several new directions researchers are exploring, it is inevitable that photoacoustic imaging will one day establish itself as a regular imaging system in the clinical practices.
Collapse
Affiliation(s)
- Dhiman Das
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, SINGAPORE
| | - Arunima Sharma
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, SINGAPORE
| | - Praveenbalaji Rajendran
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, SINGAPORE
| | - Manojit Pramanik
- School of Chemical and Biomedical Engineering, Nanyang Technological University, 70 Nanyang Drive, N1.3-B2-11, Singapore, 637457, SINGAPORE
| |
Collapse
|
14
|
Chalklen T, Jing Q, Kar-Narayan S. Biosensors Based on Mechanical and Electrical Detection Techniques. SENSORS (BASEL, SWITZERLAND) 2020; 20:E5605. [PMID: 33007906 PMCID: PMC7584018 DOI: 10.3390/s20195605] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Revised: 09/18/2020] [Accepted: 09/23/2020] [Indexed: 12/20/2022]
Abstract
Biosensors are powerful analytical tools for biology and biomedicine, with applications ranging from drug discovery to medical diagnostics, food safety, and agricultural and environmental monitoring. Typically, biological recognition receptors, such as enzymes, antibodies, and nucleic acids, are immobilized on a surface, and used to interact with one or more specific analytes to produce a physical or chemical change, which can be captured and converted to an optical or electrical signal by a transducer. However, many existing biosensing methods rely on chemical, electrochemical and optical methods of identification and detection of specific targets, and are often: complex, expensive, time consuming, suffer from a lack of portability, or may require centralised testing by qualified personnel. Given the general dependence of most optical and electrochemical techniques on labelling molecules, this review will instead focus on mechanical and electrical detection techniques that can provide information on a broad range of species without the requirement of labelling. These techniques are often able to provide data in real time, with good temporal sensitivity. This review will cover the advances in the development of mechanical and electrical biosensors, highlighting the challenges and opportunities therein.
Collapse
Affiliation(s)
| | - Qingshen Jing
- Department of Materials Science, University of Cambridge, Cambridge CB3 0FS, UK;
| | - Sohini Kar-Narayan
- Department of Materials Science, University of Cambridge, Cambridge CB3 0FS, UK;
| |
Collapse
|
15
|
Microchip capillary electrophoresis dairy device using fluorescence spectroscopy for detection of ciprofloxacin in milk samples. Sci Rep 2020; 10:13548. [PMID: 32782384 PMCID: PMC7419520 DOI: 10.1038/s41598-020-70566-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2020] [Accepted: 07/24/2020] [Indexed: 11/09/2022] Open
Abstract
Detecting antibiotics in the milk supply chain is crucial to protect humans from allergic reactions, as well as preventing the build-up of antibiotic resistance. The dairy industry has controls in place at processing facilities, but controls on dairy farms are limited to manual devices. Errors in the use of these manual devices can result in severe financial harm to the farms. This illustrates an urgent need for automated methods of detecting antibiotics on a dairy farm, to prevent the shipment of milk containing antibiotics. This work introduces the microchip capillary electrophoresis dairy device, a low-cost system that utilizes microchip capillary electrophoresis as well as fluorescence spectroscopy for the detection of ciprofloxacin contained in milk. The microchip capillary electrophoresis dairy device is operated under antibiotic-absent conditions, with ciprofloxacin not present in a milk sample, and antibiotic-present conditions, with ciprofloxacin present in a milk sample. The response curve for the microchip capillary electrophoresis dairy device is found through experimental operation with varied concentrations of ciprofloxacin. The sensitivity and limit of detection are quantified for the microchip capillary electrophoresis dairy device.
Collapse
|
16
|
Azarsa E, Jeyhani M, Ibrahim A, Tsai SSH, Papini M. A novel abrasive water jet machining technique for rapid fabrication of three-dimensional microfluidic components. BIOMICROFLUIDICS 2020; 14:044103. [PMID: 32670461 PMCID: PMC7347392 DOI: 10.1063/5.0009443] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Accepted: 06/25/2020] [Indexed: 05/16/2023]
Abstract
Microfluidic lab-on-a-chip devices are usually fabricated using replica molding, with poly(dimethylsiloxane) (PDMS) casting on a mold. Most common techniques used to fabricate microfluidic molds, such as photolithography and soft lithography, require costly facilities such as a cleanroom, and complicated steps, especially for the fabrication of three-dimensional (3D) features. For example, an often-desired 3D microchannel feature consists of intersecting channels with depth variations. This type of 3D flow focusing geometry has applications in flow cytometry and droplet generation. Various manufacturing techniques have recently been developed for the rapid fabrication of such 3D microfluidic features. In this paper, we describe a new method of mold fabrication that utilizes water jet cutting technology to fabricate free-standing structures on mild steel sheets to make a mold for PDMS casting. As a proof-of-concept, we use this fabrication technique to make a PDMS chip that has a 3D flow focusing junction, an inlet for the sample fluid, two inlets for the sheath fluid, and an outlet. The flow focusing junction is patterned into the PDMS slab with an abrupt, nearly stepwise change to the depth of the microchannel junction. We use confocal microscopy to visualize the 3D flow focusing of a sample flow using this geometry, and we also use the same geometry to generate water-in-oil droplets. This alternative approach to create microfluidic molds is versatile and may find utility in reducing the cost and complexity involved in fabricating 3D features in microfluidic devices.
Collapse
Affiliation(s)
- Ehsan Azarsa
- Department of Mechanical and Industrial Engineering, Ryerson University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada
| | | | - Amro Ibrahim
- Department of Mechanical and Industrial Engineering, Ryerson University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada
| | | | - Marcello Papini
- Department of Mechanical and Industrial Engineering, Ryerson University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada
| |
Collapse
|
17
|
Hawkins SC, Rother T, Wauer J. A numerical study of acoustic scattering by Janus spheres. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:4097. [PMID: 32611172 DOI: 10.1121/10.0001472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Accepted: 06/09/2020] [Indexed: 06/11/2023]
Abstract
Recently Janus particles have become important in several technological fields because they have interesting properties compared with homogeneous particles. The interaction of Janus particles with sound waves is of particular interest for diagnostic purposes, and also in applications in micro- and nanotechnology. In this paper the authors demonstrate that a method of fundamental solution combined with a T-matrix that is computed from far-field information can be applied with benefit to analyse the scattering of sound waves by a particular type of Janus sphere. Moreover, it is shown that this method converges faster than the conventional T-matrix method introduced by Waterman [(1969). J. Acoust. Soc. Am. 45, 1417-1429]. This is of special importance if orientation averaged scattering quantities are required, or if multiple scattering processes on Janus spheres are considered. This method is used to demonstrate the interesting phenomenon of an enhanced side scattering intensity that is larger than the forward scattering intensity, and that this effect can be strengthened using a particular configuration of two identical Janus spheres. Finally, the authors discuss a useful approximation that can be readily applied for two or more Janus spheres.
Collapse
Affiliation(s)
- Stuart C Hawkins
- Department of Mathematics and Statistics, Macquarie University, NSW 2109, Australia
| | - Tom Rother
- German Aerospace Center, D-17235 Neustrelitz, Kalkhorstweg 53, Germany
| | - Jochen Wauer
- University of Applied Sciences, D-17033 Neubrandenburg, Brodaerstr. 2, Germany
| |
Collapse
|
18
|
Affiliation(s)
- Malgorzata A. Witek
- Department of Chemistry, The University of Kansas, Lawrence, Kansas 66044, United States
- Center of Biomodular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, Kansas 66044, United States
- Department of Biomedical Engineering, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| | - Ian M. Freed
- Department of Chemistry, The University of Kansas, Lawrence, Kansas 66044, United States
- Center of Biomodular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, Kansas 66044, United States
| | - Steven A. Soper
- Department of Chemistry, The University of Kansas, Lawrence, Kansas 66044, United States
- Center of Biomodular Multiscale Systems for Precision Medicine, The University of Kansas, Lawrence, Kansas 66044, United States
- Department of Mechanical Engineering, The University of Kansas, Lawrence, Kansas 66044, United States
- Bioengineering Program, The University of Kansas, Lawrence, Kansas 66044, United States
| |
Collapse
|
19
|
Moore MJ, Sebastian JA, Kolios MC. Determination of cell nucleus-to-cytoplasmic ratio using imaging flow cytometry and a combined ultrasound and photoacoustic technique: a comparison study. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-10. [PMID: 31625322 PMCID: PMC7000884 DOI: 10.1117/1.jbo.24.10.106502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2019] [Accepted: 09/09/2019] [Indexed: 05/09/2023]
Abstract
While the nucleus-to-cytoplasmic (N:C) ratio has traditionally been used for assessing cell malignancy, most N:C measurement techniques are time-consuming and performed on thin histological sections, which prohibit assessment of three-dimensional cell structure. A combined ultrahigh frequency ultrasound (US) and photoacoustic (PA) technique was used to assess the size and N:C ratio of cultured cancer cells in three dimensions (3D). The diameters of the cells and their stained nuclei were obtained by fitting the power spectrum of backscattered US pulses and emitted PA waves, respectively, to well-established theoretical models. For comparison, an imaging flow cytometer (IFC) was also used to determine the two-dimensional cell and nucleus sizes from large cell populations using brightfield and fluorescence images, respectively. An N:C ratio was calculated for each cell using the quotient of the measured nucleus diameter and the total cell diameter. The mean N:C ratios calculated using the sound-based approach were 0.68, 0.66, and 0.54 for MCF-7, PC-3, and MDA-MB-231 cells, respectively, and were in good agreement with the corresponding values of 0.68, 0.67, and 0.68 obtained using the IFC. The combined US and PA technique, which assesses cellular N:C ratio in 3D, has potential applications in the detection of circulating tumor cells in liquid biopsies.
Collapse
Affiliation(s)
- Michael J. Moore
- Ryerson University, Department of Physics, Faculty of Science, Toronto, Ontario, Canada
- Ryerson University and St. Michael’s Hospital, Institute for Biomedical Engineering and Science Technology, Toronto, Ontario, Canada
- Li Ka Shing Knowledge Institute, Keenan Research Center for Biomedical Science, St. Michael’s Hospital, Toronto, Ontario, Canada
| | - Joseph A. Sebastian
- Ryerson University, Department of Physics, Faculty of Science, Toronto, Ontario, Canada
- Ryerson University and St. Michael’s Hospital, Institute for Biomedical Engineering and Science Technology, Toronto, Ontario, Canada
- Li Ka Shing Knowledge Institute, Keenan Research Center for Biomedical Science, St. Michael’s Hospital, Toronto, Ontario, Canada
| | - Michael C. Kolios
- Ryerson University, Department of Physics, Faculty of Science, Toronto, Ontario, Canada
- Ryerson University and St. Michael’s Hospital, Institute for Biomedical Engineering and Science Technology, Toronto, Ontario, Canada
- Li Ka Shing Knowledge Institute, Keenan Research Center for Biomedical Science, St. Michael’s Hospital, Toronto, Ontario, Canada
- Address all correspondence to Michael C. Kolios, E-mail:
| |
Collapse
|
20
|
Ratto F, Cavigli L, Borri C, Centi S, Magni G, Mazzoni M, Pini R. Hybrid organosilicon/polyol phantom for photoacoustic imaging. BIOMEDICAL OPTICS EXPRESS 2019; 10:3719-3730. [PMID: 31452970 PMCID: PMC6701555 DOI: 10.1364/boe.10.003719] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Revised: 05/17/2019] [Accepted: 05/18/2019] [Indexed: 05/15/2023]
Abstract
The rapid development of hardware and software for photoacoustic technologies is urging the establishment of dedicated tools for standardization and performance assessment. In particular, the fabrication of anatomical phantoms for photoacoustic imaging remains an open question, as current solutions have not yet gained unanimous support. Here, we propose that a hybrid material made of a water-in-oil emulsion of glycerol and polydimethylsiloxane may represent a versatile platform to host a broad taxonomy of hydrophobic and hydrophilic dyes and recapitulate the optical and acoustic features of bio tissue. For a full optical parameterization, we refer to Wróbel, et al. [ Biomed. Opt. Express7, 2088 (2016)], where this material was first presented for optical imaging. Instead, here, we complete the picture and find that its speed of sound and acoustic attenuation resemble those of pure polydimethylsiloxane, i.e. respectively 1150 ± 30 m/s and 3.5 ± 0.4 dB/(MHz·cm). We demonstrate its use under a commercial B-mode scanner and a home-made A-mode stage for photoacoustic analysis to retrieve the ground-truth encoded in a multilayer architecture containing indocyanine green, plasmonic particles and red blood cells. Finally, we verify the stability of its acoustic, optical and geometric features over a time span of three months.
Collapse
Affiliation(s)
- Fulvio Ratto
- Istituto di Fisica Applicata ‘Nello Carrara’ IFAC-CNR, Via Madonna del Piano, 10, 50019 Sesto Fiorentino (FI), Italy
| | - Lucia Cavigli
- Istituto di Fisica Applicata ‘Nello Carrara’ IFAC-CNR, Via Madonna del Piano, 10, 50019 Sesto Fiorentino (FI), Italy
| | - Claudia Borri
- Istituto di Fisica Applicata ‘Nello Carrara’ IFAC-CNR, Via Madonna del Piano, 10, 50019 Sesto Fiorentino (FI), Italy
| | - Sonia Centi
- Istituto di Fisica Applicata ‘Nello Carrara’ IFAC-CNR, Via Madonna del Piano, 10, 50019 Sesto Fiorentino (FI), Italy
| | - Giada Magni
- Istituto di Fisica Applicata ‘Nello Carrara’ IFAC-CNR, Via Madonna del Piano, 10, 50019 Sesto Fiorentino (FI), Italy
| | - Marina Mazzoni
- Istituto di Fisica Applicata ‘Nello Carrara’ IFAC-CNR, Via Madonna del Piano, 10, 50019 Sesto Fiorentino (FI), Italy
| | - Roberto Pini
- Istituto di Fisica Applicata ‘Nello Carrara’ IFAC-CNR, Via Madonna del Piano, 10, 50019 Sesto Fiorentino (FI), Italy
| |
Collapse
|
21
|
Strohm EM, Gnyawali V, Sebastian JA, Ngunjiri R, Moore MJ, Tsai SSH, Kolios MC. Sizing biological cells using a microfluidic acoustic flow cytometer. Sci Rep 2019; 9:4775. [PMID: 30886171 PMCID: PMC6423196 DOI: 10.1038/s41598-019-40895-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Accepted: 02/25/2019] [Indexed: 12/19/2022] Open
Abstract
We describe a new technique that combines ultrasound and microfluidics to rapidly size and count cells in a high-throughput and label-free fashion. Using 3D hydrodynamic flow focusing, cells are streamed single file through an ultrasound beam where ultrasound scattering events from each individual cell are acquired. The ultrasound operates at a center frequency of 375 MHz with a wavelength of 4 μm; when the ultrasound wavelength is similar to the size of a scatterer, the power spectra of the backscattered ultrasound waves have distinct features at specific frequencies that are directly related to the cell size. Our approach determines cell sizes through a comparison of these distinct spectral features with established theoretical models. We perform an analysis of two types of cells: acute myeloid leukemia cells, where 2,390 measurements resulted in a mean size of 10.0 ± 1.7 μm, and HT29 colorectal cancer cells, where 1,955 measurements resulted in a mean size of 15.0 ± 2.3 μm. These results and histogram distributions agree very well with those measured from a Coulter Counter Multisizer 4. Our technique is the first to combine ultrasound and microfluidics to determine the cell size with the potential for multi-parameter cellular characterization using fluorescence, light scattering and quantitative photoacoustic techniques.
Collapse
Affiliation(s)
- Eric M Strohm
- Department of Physics, Ryerson University, 350 Victoria St, Toronto, Canada
- Institute for Biomedical Engineering and Science Technology, a partnership between Ryerson University and St. Michael's Hospital, M5B 1W8, Toronto, Canada
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael's Hospital, M5B 1W8, Toronto, Canada
| | - Vaskar Gnyawali
- Department of Mechanical and Industrial Engineering, Ryerson University, 350 Victoria St, Toronto, Canada
- Institute for Biomedical Engineering and Science Technology, a partnership between Ryerson University and St. Michael's Hospital, M5B 1W8, Toronto, Canada
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael's Hospital, M5B 1W8, Toronto, Canada
| | - Joseph A Sebastian
- Department of Physics, Ryerson University, 350 Victoria St, Toronto, Canada
- Institute for Biomedical Engineering and Science Technology, a partnership between Ryerson University and St. Michael's Hospital, M5B 1W8, Toronto, Canada
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael's Hospital, M5B 1W8, Toronto, Canada
| | - Robert Ngunjiri
- Department of Physics, Ryerson University, 350 Victoria St, Toronto, Canada
- Institute for Biomedical Engineering and Science Technology, a partnership between Ryerson University and St. Michael's Hospital, M5B 1W8, Toronto, Canada
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael's Hospital, M5B 1W8, Toronto, Canada
| | - Michael J Moore
- Department of Physics, Ryerson University, 350 Victoria St, Toronto, Canada
- Institute for Biomedical Engineering and Science Technology, a partnership between Ryerson University and St. Michael's Hospital, M5B 1W8, Toronto, Canada
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael's Hospital, M5B 1W8, Toronto, Canada
| | - Scott S H Tsai
- Department of Mechanical and Industrial Engineering, Ryerson University, 350 Victoria St, Toronto, Canada
- Institute for Biomedical Engineering and Science Technology, a partnership between Ryerson University and St. Michael's Hospital, M5B 1W8, Toronto, Canada
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael's Hospital, M5B 1W8, Toronto, Canada
| | - Michael C Kolios
- Department of Physics, Ryerson University, 350 Victoria St, Toronto, Canada.
- Institute for Biomedical Engineering and Science Technology, a partnership between Ryerson University and St. Michael's Hospital, M5B 1W8, Toronto, Canada.
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael's Hospital, M5B 1W8, Toronto, Canada.
| |
Collapse
|