Kumari N, Ganga KP, Ojha V, Kumar S, Jagia P, Naik N, Gulati G, Sharma S. Low-dose ultra-high-pitch computed tomography coronary angiography: identifying the optimum combination of iteration strength and radiation dose reduction strategies to achieve true submillisievert scans. Diagn Interv Radiol 2023; 29:268-275. [PMID: 36987879 PMCID: PMC10679714 DOI: 10.4274/dir.2021.0849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Accepted: 07/01/2021] [Indexed: 01/15/2023]
Abstract
PURPOSE To identify the optimum strength of advanced modeled iterative reconstruction (ADMIRE) to achieve the best subjective and objective image quality when combining three-dose reduction strategies, ultra-high-pitch computed tomography coronary angiography (FLASH CTCA; with single-dose ivabradine to lower heart rate), low tube voltage, and ADMIRE. METHODS Sixty consecutive patients underwent FLASH CTCA at 100 kVp in this single-center prospective study. Single-dose ivabradine was administered to patients whose heart rate was above 75 bpm. Images were reconstructed using the three highest strengths of ADMIRE (A3, A4, and A5). Objective and subjective image quality (using a Likert scale) were evaluated in the three datasets. RESULTS The signal strength remained unchanged but mean noise significantly reduced across the increasing strengths of ADMIRE [signal: 513.78 ± 101.7 Hounsfield units (HU) at A3, 515.6 ± 100.5 HU at A4, and 519.7 ± 107.9 HU at A5; noise: 23.4 ± 4.5 HU at A3, 20.2 ± 3.6 HU at A4, and 17.2 ± 3.3 HU at A5]. Signal-to-noise and contrast-to-noise ratios were the highest at A5, and A5 offered significantly higher Likert scores in image noise, vessel sharpness, and overall image quality than A3 or A4. Additionally, A5 did not interfere with image interpretation in any patient. CONCLUSION Using all three dose reduction strategies during FLASH CTCA along with single-dose ivabradine administration ensures minimal radiation exposure in daily practice. In this study, A5 datasets had the best overall subjective and objective image quality despite their "plastic appearance". In the future, enhanced dose reduction can be obtained by further lowering tube voltages.
Collapse
Affiliation(s)
- Nidhi Kumari
- Department of Cardiovascular Radiology and Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India
| | - Kartik P. Ganga
- Department of Cardiovascular Radiology and Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India
| | - Vineeta Ojha
- Department of Cardiovascular Radiology and Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India
| | - Sanjeev Kumar
- Department of Cardiovascular Radiology and Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India
| | - Priya Jagia
- Department of Cardiovascular Radiology and Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India
| | - Nitish Naik
- Department of Cardiology, All India Institute of Medical Sciences, New Delhi, India
| | - Gurpreet Gulati
- Department of Cardiovascular Radiology and Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India
| | - Sanjiv Sharma
- Department of Cardiovascular Radiology and Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India
| |
Collapse
|
2
|
Otgonbaatar C, Ryu JK, Shin J, Kim HM, Seo JW, Shim H, Hwang DH. Deep learning reconstruction allows for usage of contrast agent of lower concentration for coronary CTA than filtered back projection and hybrid iterative reconstruction. Acta Radiol 2023; 64:1007-1017. [PMID: 35979586 DOI: 10.1177/02841851221118476] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND The demand for homogeneous and higher vascular contrast enhancement is critical to provide an appropriate interpretation of abnormal vascular findings in coronary computed tomography angiography (CTA). PURPOSE To evaluate the effect of various contrast media concentrations (Iohexol-370, Iohexol-300, Iohexol-240) and image reconstructions (filtered back projection [FBP], hybrid iterative reconstruction [IR], and deep learning reconstruction [DLR]) on coronary CTA. MATERIAL AND METHODS A total of 63 patients referred for coronary CTA between July and October 2021 were enrolled in this prospective study, and they randomly received one of three contrast media. CTA images were reconstructed with FBP, hybrid IR, and DLR. The CT attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated for all three images. The images were subjectively evaluated by two radiologists in terms of overall image quality, artifacts, image noise, and vessel wall delineation on a 5-point Likert scale. RESULTS The application of DLR resulted in significantly lower image noise; higher CT attenuation, SNR, and CNR; and better subjective analysis among the three different concentrations of contrast media groups (P < 0.001). There was no significant difference in the CT attenuation of the left ventricle (P = 0.089) and coronary arteries (P = 0.072) between hybrid IR at Iohexol-300 and DLR at Iohexol-240. Furthermore, application of DLR to the Iohexol-240 significantly improved SNR and CNR; it achieved higher subjective scores compared with hybrid IR at Iohexol-300 (P < 0.001). CONCLUSION We suggest that using DLR with Iohexol-240 contrast media is preferable to hybrid IR with Iohexol-300 contrast media in coronary CTA.
Collapse
Affiliation(s)
- Chuluunbaatar Otgonbaatar
- Department of Radiology, 26725Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Jae-Kyun Ryu
- Medical Imaging AI Research Center, 496517Canon Medical Systems Korea, Seoul, Republic of Korea
| | - Jaemin Shin
- Department of Neurology, 58934Korea University Guro Hospital, Seoul, Republic of Korea
| | - Han Myun Kim
- Department of Radiology, 65521Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Republic of Korea
| | - Jung Wook Seo
- Department of Radiology, 119750Inje University Ilsan Paik Hospital, Goyang, Republic of Korea
| | - Hackjoon Shim
- Medical Imaging AI Research Center, 496517Canon Medical Systems Korea, Seoul, Republic of Korea
- ConnectAI Research Center, 37991Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Dae Hyun Hwang
- Department of Radiology, 65521Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
3
|
Sun W, Tan H, Wang Y, Xie A, Tan X, Liu P, Xu D, Huang F. Pulmonary CT scans of white rabbits using the selective photon shield technique of the third-generation dual-source CT. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2022; 42:021527. [PMID: 35580575 DOI: 10.1088/1361-6498/ac7089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Accepted: 05/17/2022] [Indexed: 06/15/2023]
Abstract
This study aims to optimise the protocol for the low-dose pulmonary computed tomography (CT) scanning of infants by studying the effects of the selective photon shield (SPS) technique of the third-generation dual-source CT (DSCT) on the image quality and radiation dose of a chest CT in white rabbits under different tube currents. Twelve white rabbits of a similar weight to an infant were selected and randomly divided into an experimental group and a control group. The experimental groups (A1-A5) were scanned at low dose by the third-generation DSCT using SPS under different tube current × time (60, 50, 40, 30, and 20 mAs). The control group (B) was scanned under a conventional tube voltage (100 kV) and current × time (20 mAs). Advanced model iterative reconstruction at strength three was used for the objective and subjective evaluation of the image quality and radiation dose of the lung and mediastinal windows. With the standard deviation of the air in the trachea as image noise, the signal-to-noise ratio (SNR), contrast-to-noise ratio, and CT values of each site were evaluated. Radiation doses were compared using the volume CT dose index, dose length product, and effective dose. The differences in subjective image quality between groups A2 and B were not statistically significant (P= 0.34). The differences in the SNRs of the lung and mediastinal windows between groups A2 and B were not statistically significant (P> 0.05). The radiation dose of group A2 was 83.2% lower than that of group B. The SPS of the third-generation DSCT under 50 mAs might be applied in the pulmonary CT examination of infants.
Collapse
Affiliation(s)
- Wenjie Sun
- Department of Radiology, Hunan Provincial People's Hospital (First Affiliated Hospital of Hunan Normal University), No. 61, West Jiefang Road, Changsha, Hunan 410005, People's Republic of China
| | - Hui Tan
- Department of Radiology, Hunan Provincial People's Hospital (First Affiliated Hospital of Hunan Normal University), No. 61, West Jiefang Road, Changsha, Hunan 410005, People's Republic of China
| | - Yi Wang
- Department of Radiology, Hunan Provincial People's Hospital (First Affiliated Hospital of Hunan Normal University), No. 61, West Jiefang Road, Changsha, Hunan 410005, People's Republic of China
| | - An Xie
- Department of Radiology, Hunan Provincial People's Hospital (First Affiliated Hospital of Hunan Normal University), No. 61, West Jiefang Road, Changsha, Hunan 410005, People's Republic of China
| | - Xianzheng Tan
- Department of Radiology, Hunan Provincial People's Hospital (First Affiliated Hospital of Hunan Normal University), No. 61, West Jiefang Road, Changsha, Hunan 410005, People's Republic of China
| | - Peng Liu
- Department of Radiology, Hunan Provincial People's Hospital (First Affiliated Hospital of Hunan Normal University), No. 61, West Jiefang Road, Changsha, Hunan 410005, People's Republic of China
| | - Dan Xu
- Department of Radiology, Hunan Provincial People's Hospital (First Affiliated Hospital of Hunan Normal University), No. 61, West Jiefang Road, Changsha, Hunan 410005, People's Republic of China
| | - Feng Huang
- Department of Radiology, Hunan Provincial People's Hospital (First Affiliated Hospital of Hunan Normal University), No. 61, West Jiefang Road, Changsha, Hunan 410005, People's Republic of China
| |
Collapse
|
4
|
Zhang Q, Mi H, Shi X, Li W, Guo S, Wang P, Suo H, Wang Z, Jin S, Yan F, Niu Y, Xian J. Higher Iodine Concentration Enables Radiation Dose Reduction in Coronary CT Angiography. Acad Radiol 2021; 28:1072-1080. [PMID: 32553279 DOI: 10.1016/j.acra.2020.05.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Revised: 05/13/2020] [Accepted: 05/13/2020] [Indexed: 01/01/2023]
Abstract
RATIONALE AND OBJECTIVES To test whether higher iodine concentration together with higher noise level could lead to a further dose reduction in an already low dose coronary CT angiography (CCTA) protocol without comprising image quality. MATERIALS AND METHODS One hundred eighty patients with suspected coronary artery disease (CAD) were randomly assigned into three groups: (a) conventional dose (CD) group, 100 kV with a noise index (NI) of 25 and iohexol (350 mg I/ml); (b) low dose (LD) group, 80 kV with a NI of 25 and iohexol (350 mg I/ml); (c) further low dose (FLD) group, 80 kV with a NI of 30 and iomeprol (400 mg I/ml). The volume and injection rate of contrast medium were fixed at 60 ml and 5 ml/s. The radiation dose (volume CT dose index [CTDIvol], dose length product [DLP], and effective dose [ED]) were recorded. For image quality, both quantitative (enhancement, noise, signal-to-noise ratio [SNR], and contrast-to-noise ratio [CNR]) and qualitative indices were assessed. RESULTS Compared to the CD group, ED was reduced by 16% and 42% in the LD and FLD groups, respectively (p < 0.05). Qualitative analysis showed no significant difference among the 3 groups (p > 0.05), while quantitative analysis revealed significantly higher attenuation in the LD and FLD groups. Signal-to-noise ratios and CNRs of the LD and FLD groups were significantly higher except for the CNR at the left circumflex branch of the FLD group (p < 0.05). CONCLUSION Increasing iodine concentration and noise level may further reduce the radiation dose by 26% on top of a 16% reduction from 100 kV to 80 kV without image quality compromise.
Collapse
Affiliation(s)
- Qing Zhang
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Haifeng Mi
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Xubo Shi
- Department of Cardiology, Beijing Tongren Hospital, Capital Medical University, Beijing, P.R. China
| | - Wei Li
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Senlin Guo
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Ping Wang
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Hongna Suo
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Ziyi Wang
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Shanshan Jin
- Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing, P.R. China
| | - Fei Yan
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Yantao Niu
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Junfang Xian
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China.
| |
Collapse
|
5
|
Artificial Intelligence to Assist in Exclusion of Coronary Atherosclerosis During CCTA Evaluation of Chest Pain in the Emergency Department: Preparing an Application for Real-world Use. J Digit Imaging 2021; 34:554-571. [PMID: 33791909 DOI: 10.1007/s10278-021-00441-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 11/09/2020] [Accepted: 03/01/2021] [Indexed: 12/22/2022] Open
Abstract
Coronary computed tomography angiography (CCTA) evaluation of chest pain patients in an emergency department (ED) is considered appropriate. While a "negative" CCTA interpretation supports direct patient discharge from an ED, labor-intensive analyses are required, with accuracy in jeopardy from distractions. We describe the development of an artificial intelligence (AI) algorithm and workflow for assisting qualified interpreting physicians in CCTA screening for total absence of coronary atherosclerosis. The two-phase approach consisted of (1) phase 1-development and preliminary testing of an algorithm for vessel-centerline extraction classification in a balanced study population (n = 500 with 50% disease prevalence) derived by retrospective random case selection, and (2) phase 2-simulated clinical Trialing of developed algorithm on a per-case (entire coronary artery tree) basis in a more "real-world" study population (n = 100 with 28% disease prevalence) from an ED chest pain series. This allowed pre-deployment evaluation of the AI-based CCTA screening application which provides vessel-by-vessel graphic display of algorithm inference results integrated into a clinically capable viewer. Algorithm performance evaluation used area under the receiver operating characteristic curve (AUC-ROC); confusion matrices reflected ground truth vs AI determinations. The vessel-based algorithm demonstrated strong performance with AUC-ROC = 0.96. In both phase 1 and phase 2, independent of disease prevalence differences, negative predictive values at the case level were very high at 95%. The rate of completion of the algorithm workflow process (96% with inference results in 55-80 s) in phase 2 depended on adequate image quality. There is potential for this AI application to assist in CCTA interpretation to help extricate atherosclerosis from chest pain presentations.
Collapse
|
6
|
Zhao Y, Li D, Liu Z, Geng X, Zhang T, Xu Y. Comparison of image quality and radiation dose using different pre-ASiR-V and post-ASiR-V levels in coronary computed tomography angiography. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2021; 29:125-134. [PMID: 33164983 DOI: 10.3233/xst-200754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
OBJECTIVE To determine the optimal pre-adaptive and post-adaptive level statistical iterative reconstruction V (ASiR-V) for improving image quality and reducing radiation dose in coronary computed tomography angiography (CCTA). METHODS The study was divided into two parts. In part I, 150 patients for CCTA were prospectively enrolled and randomly divided into 5 groups (A, B, C, D, and E) with progressive scanning from 40% to 80% pre-ASiR-V with 10% intervals and reconstructing with 70% post-ASiR-V. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Subjective image quality was assessed using a 5-point scale. The CT dose index volume (CTDIvol) and dose-length product (DLP) of each patient were recorded and the effective radiation dose (ED) was calculated after statistical analysis by optimizing for the best pre-ASiR-V value with the lowest radiation dose while maintaining overall image quality. In part II, the images were reconstructed with the recommended optimal pre-ASiR-V values in part I (D group) and 40%-90% of post-ASiR-V. The reconstruction group (D group) was divided into 6 subgroups (interval 10%, D0:40% post-ASiR-V, D1:50% post - ASiR-V, D2:60% post-ASiR-V, D3:70% post-ASiR-V, D4:80% post-ASiR-V, and D5:90% post-ASiR-V).The SNR and CNR of D0-D5 subgroups were calculated and analyzed using one-way analysis of variance, and the consistency of the subjective scores used the k test. RESULTS There was no significant difference in the SNRs, CNRs, and image quality scores among A, B, C, and D groups (P > 0.05). The SNR, CNR, and image quality scores of the E group were lower than those of the A, B, C, and D groups (P < 0.05). The mean EDs in the B, C, and D groups were reduced by 7.01%, 13.37%, and 18.87%, respectively, when compared with that of the A group. The SNR and CNR of the D4-D5 subgroups were higher than the D0-D3 subgroups, and the image quality scores of the D4 subgroups were higher than the other subgroups (P < 0.05). CONCLUSION The wide-detector combined with 70% pre-ASiR-V and 80% post-ASiR-V significantly reduces the radiation dose of CCTA while maintaining overall image quality as compared with the manufacture's recommendation of 40% pre-ASiR-V.
Collapse
Affiliation(s)
- Yongxia Zhao
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding, China
| | - Dongxue Li
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding, China
| | - Zhichao Liu
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding, China
| | - Xue Geng
- Department of Radiology, Baoding No. 2 Hospital, Baoding, China
| | - Tianle Zhang
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding, China
| | - Yize Xu
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding, China
| |
Collapse
|
7
|
Toia P, La Grutta L, Smeraldi T, Agnello F, Grassedonio E, Maffei E, Midiri M, Cademartiri F. Updated diagnostic & prognostic paradigm for CAD: a narrative review. Cardiovasc Diagn Ther 2020; 10:1979-1991. [PMID: 33381438 PMCID: PMC7758757 DOI: 10.21037/cdt-20-526] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Accepted: 09/23/2020] [Indexed: 12/24/2022]
Abstract
Cardiovascular diseases are the first cause of death globally; early detection of coronary artery disease (CAD) is a challenge for clinicians and radiologists. Over the past 2 decades there have been several improvements in the methods for the assessment of diagnosis and prognosis in patients with suspected CAD; most of these methods are imaging methods and they operate with high-end technologies. Cardiac computed tomography (CCT) as we know it today was introduced in 1998 and has ever progressed with constant pace. The first decade was the technical validation phase of the method while the second decade was the clinical validation phase. CCT has developed an excellent diagnostic and prognostic value; technological development together with radiation dose reduction, contributed to the widening of its clinical indications. The diagnostic value of CCT is particularly important as a first line in symptomatic patients with suspected obstructive CAD and low-to-intermediate cardiovascular risk. It is a test that should come, whenever possible, in front of functional evaluation because of its very high sensitivity and negative predictive value. The prognostic value of CCt is still investigational, even though it is becoming quite evident that the atherosclerotic phenotype plays a major role in the determination of prognosis, and as consequence, in the individualization of optimal pharmacological therapy, especially in the cohort without significant obstructive CAD. Recently, scientific and practical guidelines have been updated taking into account the role of CCT, which is able to provide a reliable and fast diagnosis with an additional resources optimization. Multiple registries and trials have been developed and will be summarized in this review. Recent guidelines highlighted the role of CCT in diagnosing suspected CAD.
Collapse
Affiliation(s)
- Patrizia Toia
- Department of Biomedicine, Neurosciences and Advanced Diagnostic (BiND), University of Palermo, Italy
| | - Ludovico La Grutta
- Department of Health Promotion Sciences Maternal and Infantile Care, Internal Medicine and Medical Specialities (ProMISE), University of Palermo, Italy
| | - Tommaso Smeraldi
- Department of Biomedicine, Neurosciences and Advanced Diagnostic (BiND), University of Palermo, Italy
| | - Francesco Agnello
- Department of Biomedicine, Neurosciences and Advanced Diagnostic (BiND), University of Palermo, Italy
| | - Emanuele Grassedonio
- Department of Biomedicine, Neurosciences and Advanced Diagnostic (BiND), University of Palermo, Italy
| | - Erica Maffei
- Department of Radiology, Area Vasta 1, ASUR Marche, Urbino (PU), Italy
| | - Massimo Midiri
- Department of Biomedicine, Neurosciences and Advanced Diagnostic (BiND), University of Palermo, Italy
| | | |
Collapse
|
8
|
Hongwei W, Chunling J, Chenjian L, Hui L. Quantificational evaluation of the resolving power of qualitative biomarkers with different cardinal numbers based on a magnitude-standardized index. J Bioinform Comput Biol 2020; 18:2050036. [PMID: 33064053 DOI: 10.1142/s0219720020500365] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Biomarkers are used for clinical diagnostic purposes, but existing indexes exhibit limitations in terms of the resolving power of biomarkers. This paper proposes a new index, the magnitude-standardized index (MSI), to describe the quantitative variations and resolving powers of different biomarkers. In MSI analysis models, variation scales for ratios and differences are considered simultaneously, and a higher MSI value implies a stronger risk or effect for a biological factor. We explain the rationale for the MSI via hybrid and geometric methods and verify its efficacy through simulation experiments. Our results indicate that the MSI is superior to the Youden index and odds ratio for describing resolving power. When two biomarkers with similar Youden index values, odds ratios, or MSI values but different positive test rates (or cardinal numbers) were combined, all three index values increased; however, only the MSI value remained relatively stable. For a very small cardinal number, such as that of a single nucleotide polymorphism, the MSI value is at most half of the maximum value (0.5), allowing comparisons between MSI values for biomarkers with different cardinal numbers. The MSI can thus provide a better quantifiable evaluation of the resolving power of biomarkers with different cardinal numbers.
Collapse
Affiliation(s)
- Wang Hongwei
- Modern Educational Technology Center, Dalian Medical University, No. 9 West Section Lvshun South Road, Dalian 116044, P. R. China
| | - Jiang Chunling
- College of Basic Medical Sciences, Dalian Medical University, No. 9 West Section Lvshun, South Road, Dalian 116044, P. R. China
| | - Li Chenjian
- Department of Mathematical Sciences, College of Science, Tsinghua University, Beijing 100062, P. R. China
| | - Liu Hui
- College of Medical Laboratory, Dalian Medical University, No. 9 West Section Lvshun South Road, Dalian 116044, P. R. China
| |
Collapse
|
9
|
Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography. PLoS One 2020; 15:e0236108. [PMID: 32673356 PMCID: PMC7365455 DOI: 10.1371/journal.pone.0236108] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 06/29/2020] [Indexed: 11/19/2022] Open
Abstract
Background To investigate the feasibility of a low tube voltage (80 kVp) protocol with low concentration contrast media (CM) (iodixanol 320 mgl/ml) as compared with a high tube voltage (100 kVp) protocol with high concentration CM (iomeprol 400 mgl/ml) in coronary CT angiography (CCTA) for patients with body mass index less than 30. Materials and methods A total of 93 patients were randomly assigned into three groups and underwent CCTA as follows: Group A) 100 kVp, 100–350 mAs, 400 mgl/ml CM at 4ml/s, and reconstructed with filtered back projection; Group B and C) 80 kVp, 100–450 mAs, 320 mgl/ml CM at 4 ml/s and 5 ml/s, respectively and reconstructed with iterative reconstruction. Objective and subjective image quality (IQ) was analyzed. Results The image noise, intravascular attenuation, signal-to-noise ratio and contrast-to-noise ratio of major coronary arteries did not differ significantly among three groups. Subjective IQ analyses on vascular attenuation and image noise did not differ significantly, either (all of p > 0.05). Qualitative IQ of Group B and C was non-inferior to that of Group A. Substantial reduction of radiation exposure was achieved in group B (2.60 ± 0.48 mSv) and C (2.72 ± 0.54 mSv), compared with group A (3.58 ± 0.67 mSv) (p < 0.05). Conclusion CCTA at 80 kVp with 320 mgl/ml CM and iterative reconstruction is feasible, achieving radiation dose reduction, while preserving IQ.
Collapse
|
10
|
Infante T, Del Viscovo L, De Rimini ML, Padula S, Caso P, Napoli C. Network Medicine: A Clinical Approach for Precision Medicine and Personalized Therapy in Coronary Heart Disease. J Atheroscler Thromb 2020; 27:279-302. [PMID: 31723086 PMCID: PMC7192819 DOI: 10.5551/jat.52407] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Accepted: 09/24/2019] [Indexed: 12/13/2022] Open
Abstract
Early identification of coronary atherosclerotic pathogenic mechanisms is useful for predicting the risk of coronary heart disease (CHD) and future cardiac events. Epigenome changes may clarify a significant fraction of this "missing hereditability", thus offering novel potential biomarkers for prevention and care of CHD. The rapidly growing disciplines of systems biology and network science are now poised to meet the fields of precision medicine and personalized therapy. Network medicine integrates standard clinical recording and non-invasive, advanced cardiac imaging tools with epigenetics into deep learning for in-depth CHD molecular phenotyping. This approach could potentially explore developing novel drugs from natural compounds (i.e. polyphenols, folic acid) and repurposing current drugs, such as statins and metformin. Several clinical trials have exploited epigenetic tags and epigenetic sensitive drugs both in primary and secondary prevention. Due to their stability in plasma and easiness of detection, many ongoing clinical trials are focused on the evaluation of circulating miRNAs (e.g. miR-8059 and miR-320a) in blood, in association with imaging parameters such as coronary calcifications and stenosis degree detected by coronary computed tomography angiography (CCTA), or functional parameters provided by FFR/CT and PET/CT. Although epigenetic modifications have also been prioritized through network based approaches, the whole set of molecular interactions (interactome) in CHD is still under investigation for primary prevention strategies.
Collapse
Affiliation(s)
- Teresa Infante
- Department of Advanced Clinical and Surgical Sciences, University of Campania “Luigi Vanvitelli”, Naples, Italy
| | - Luca Del Viscovo
- Department of Precision Medicine, Section of Diagnostic Imaging, University of Campania “Luigi Vanvitelli”, Naples, Italy
| | | | - Sergio Padula
- Department of Cardiology, A.O.R.N. Dei Colli, Monaldi Hospital, Naples, Italy
| | - Pio Caso
- Department of Cardiology, A.O.R.N. Dei Colli, Monaldi Hospital, Naples, Italy
| | - Claudio Napoli
- Clinical Department of Internal Medicine and Specialistics, Department of Advanced Clinical and Surgical Sciences, University of Campania “Luigi Vanvitelli”, Naples, Italy
- IRCCS SDN, Naples, Italy
| |
Collapse
|
11
|
Coronary computed tomography angiography using model-based iterative reconstruction algorithms in the detection of significant coronary stenosis: how the plaque type influences the diagnostic performance. Pol J Radiol 2019; 84:e522-e529. [PMID: 32082450 PMCID: PMC7016499 DOI: 10.5114/pjr.2019.91259] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Accepted: 11/04/2019] [Indexed: 01/14/2023] Open
Abstract
Purpose To evaluate the ability of coronary computed tomography angiography (CCTA) with model-based iterative reconstruction (MBIR) algorithm in detecting significant coronary artery stenosis compared with invasive coronary angiography (ICA). Material and methods We retrospectively identified 55 patients who underwent CCTA using the MBIR algorithm with evidence of at least one significant stenosis (≥ 50%) and an ICA within three months. Patients were stratified based on calcium score; stenoses were classified by type and by coronary segment involved. Dose-length-product was compared with the literature data obtained with previous reconstruction algorithms. Coronary artery stenosis was estimated on ICAs based on a qualitative method. Results CCTA data were confirmed by ICA in 89% of subjects, and in 73% and 94% of patients with CS < 400 and ≥ 400, respectively. ICA confirmed 81% of calcific stenoses, 91% of mixed, and 67% of soft plaques. Both the dose exposure of patients with prospective acquisition (34) and the exposure of the whole population were significantly lower than the standard of reference (p < 0.001 and p = 0.007). Conclusions CCTA with MBIR is valuable in detecting significant coronary artery stenosis with a solid reduction of radiation dose. Diagnostic performance was influenced by plaque composition, being lower compared with ICA for patients with lower CAC score and soft plaques; the visualisation of an intraluminal hypodensity could cause false positives, particularly in D1 and MO segments.
Collapse
|