1
|
Chu SS, Nguyen HA, Zhang J, Tabassum S, Cao H. Towards Multiplexed and Multimodal Biosensor Platforms in Real-Time Monitoring of Metabolic Disorders. SENSORS (BASEL, SWITZERLAND) 2022; 22:5200. [PMID: 35890880 PMCID: PMC9323394 DOI: 10.3390/s22145200] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 07/05/2022] [Accepted: 07/07/2022] [Indexed: 06/15/2023]
Abstract
Metabolic syndrome (MS) is a cluster of conditions that increases the probability of heart disease, stroke, and diabetes, and is very common worldwide. While the exact cause of MS has yet to be understood, there is evidence indicating the relationship between MS and the dysregulation of the immune system. The resultant biomarkers that are expressed in the process are gaining relevance in the early detection of related MS. However, sensing only a single analyte has its limitations because one analyte can be involved with various conditions. Thus, for MS, which generally results from the co-existence of multiple complications, a multi-analyte sensing platform is necessary for precise diagnosis. In this review, we summarize various types of biomarkers related to MS and the non-invasively accessible biofluids that are available for sensing. Then two types of widely used sensing platform, the electrochemical and optical, are discussed in terms of multimodal biosensing, figure-of-merit (FOM), sensitivity, and specificity for early diagnosis of MS. This provides a thorough insight into the current status of the available platforms and how the electrochemical and optical modalities can complement each other for a more reliable sensing platform for MS.
Collapse
Affiliation(s)
- Sung Sik Chu
- Department of Biomedical Engineering, Henry Samueli School of Engineering, University of California Irvine, Irvine, CA 92697, USA; (S.S.C.); (J.Z.)
| | - Hung Anh Nguyen
- Department of Electrical Engineering and Computer Science, Henry Samueli School of Engineering, University of California Irvine, Irvine, CA 92697, USA;
| | - Jimmy Zhang
- Department of Biomedical Engineering, Henry Samueli School of Engineering, University of California Irvine, Irvine, CA 92697, USA; (S.S.C.); (J.Z.)
| | - Shawana Tabassum
- Department of Electrical Engineering, College of Engineering, The University of Texas at Tyler, Tyler, TX 75799, USA
| | - Hung Cao
- Department of Biomedical Engineering, Henry Samueli School of Engineering, University of California Irvine, Irvine, CA 92697, USA; (S.S.C.); (J.Z.)
- Department of Electrical Engineering and Computer Science, Henry Samueli School of Engineering, University of California Irvine, Irvine, CA 92697, USA;
| |
Collapse
|
2
|
El-Naggar ME, Abu Ali OA, Saleh DI, Abu-Saied MA, Khattab TA. Preparation of green and sustainable colorimetric cotton assay using natural anthocyanins for sweat sensing. Int J Biol Macromol 2021; 190:894-903. [PMID: 34534584 DOI: 10.1016/j.ijbiomac.2021.09.049] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 08/25/2021] [Accepted: 09/09/2021] [Indexed: 12/20/2022]
Abstract
Herein, we develop a novel smart cotton swab as a diagnostic assay for onsite monitoring of sweat pH changes toward potential applications in monitoring human healthcare and drug exam. Anthocyanin (Ac) can be extracted from Brassica oleracea var. capitata f. rubra using a simple procedure. Then, it can be used as a direct dye into cotton fibers using potash alum as mordant (M) to fix the anthocyanin dye onto the surface of the cotton fabric (Cot). This was monitored by generating mordant/anthocyanin nanoparticles (MAcNPs) onto the fabric surface. The cotton sensor assay demonstrated colorimetric changes in the ultraviolet-visible absorbance spectral analysis associated with a blueshift from 588 to 422 nm with increasing the pH of a perspiration simulant fluid. The biochromic performance of the dyed cotton diagnostic assay depended essentially on the halochromic activity of the anthocyanin spectroscopic probe to demonstrate a color change from pink to green due to intramolecular charge transfer occurring on the anthocyanin chromophore. After dyeing, no significant defects were detected in air-permeability and bend length. High colorfastness was investigated for the dyed cotton fabrics.
Collapse
Affiliation(s)
- Mehrez E El-Naggar
- Textile Research Division, National Research Center (Affiliation ID: 60014618), Dokki, Cairo, Egypt.
| | - Ola A Abu Ali
- Department of Chemistry, College of Science, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia
| | - Dalia I Saleh
- Department of Chemistry, College of Science, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia
| | - M A Abu-Saied
- Polymeric Materials Research Department, Advanced Technology and New Materials Research Institute, City of Scientific Research and Technological Applications (SRTA-CITY), New Borg El-Arab City, 21934, Alexandria, Egypt
| | - Tawfik A Khattab
- Textile Research Division, National Research Center (Affiliation ID: 60014618), Dokki, Cairo, Egypt
| |
Collapse
|
3
|
Kim H, Park S, Jeong IG, Song SH, Jeong Y, Kim CS, Lee KH. Noninvasive Precision Screening of Prostate Cancer by Urinary Multimarker Sensor and Artificial Intelligence Analysis. ACS NANO 2021; 15:4054-4065. [PMID: 33296173 DOI: 10.1021/acsnano.0c06946] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Screening for prostate cancer relies on the serum prostate-specific antigen test, which provides a high rate of false positives (80%). This results in a large number of unnecessary biopsies and subsequent overtreatment. Considering the frequency of the test, there is a critical unmet need of precision screening for prostate cancer. Here, we introduced a urinary multimarker biosensor with a capacity to learn to achieve this goal. The correlation of clinical state with the sensing signals from urinary multimarkers was analyzed by two common machine learning algorithms. As the number of biomarkers was increased, both algorithms provided a monotonic increase in screening performance. Under the best combination of biomarkers, the machine learning algorithms screened prostate cancer patients with more than 99% accuracy using 76 urine specimens. Urinary multimarker biosensor leveraged by machine learning analysis can be an important strategy of precision screening for cancers using a drop of bodily fluid.
Collapse
Affiliation(s)
- Hojun Kim
- Biomaterials Research Center, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea
| | - Sungwook Park
- Biomaterials Research Center, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea
| | - In Gab Jeong
- Department of Urology, Asan Medical Center (AMC), University of Ulsan College of Medicine, Seoul 05505, Republic of Korea
| | - Sang Hoon Song
- Department of Urology, Asan Medical Center (AMC), University of Ulsan College of Medicine, Seoul 05505, Republic of Korea
| | - Youngdo Jeong
- Biomaterials Research Center, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea
| | - Choung-Soo Kim
- Department of Urology, Asan Medical Center (AMC), University of Ulsan College of Medicine, Seoul 05505, Republic of Korea
| | - Kwan Hyi Lee
- Biomaterials Research Center, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea
- KU-KIST Graduate School of Converging Science and Technology, Korea University, Seoul 02841, Republic of Korea
| |
Collapse
|
4
|
Choi DH, Gonzales M, Kitchen GB, Phan DT, Searson PC. A Capacitive Sweat Rate Sensor for Continuous and Real-Time Monitoring of Sweat Loss. ACS Sens 2020; 5:3821-3826. [PMID: 33263987 DOI: 10.1021/acssensors.0c01219] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Individualized measurement of sweat loss under heat stress is important in assessing physical performance and preventing heat-related illness for athletes or individuals working in extreme environments. The objective of this work was to develop a low-cost and easy-to-fabricate wearable sensor that enables accurate real-time measurement of sweat rate. A capacitive-type sensor was fabricated from two conducting parallel plates, plastic insulating layers, and a central microfluidic channel formed by laser cutting a plastic film. The device has no microfabricated electrodes and is assembled using adhesive tape. Sensor accuracy was validated at different flow rates and confirmed using an equivalent circuit model of the device. On-body measurements demonstrate the feasibility of real-time measurements and show good agreement with values determined from a conventional sweat collection device.
Collapse
Affiliation(s)
- Dong-Hoon Choi
- Institute for Nanobiotechnology, John Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218, United States
| | - Mark Gonzales
- Institute for Nanobiotechnology, John Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218, United States
| | - Grant B. Kitchen
- Institute for Nanobiotechnology, John Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218, United States
| | - Dinh-Tuan Phan
- Institute for Nanobiotechnology, John Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218, United States
| | - Peter C. Searson
- Institute for Nanobiotechnology, John Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218, United States
- Department of Materials Science and Engineering, John Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218, United States
| |
Collapse
|
5
|
The Dynamic Response of Sweat Chloride to Changes in Exercise Load Measured by a Wearable Sweat Sensor. Sci Rep 2020; 10:7699. [PMID: 32382047 PMCID: PMC7205967 DOI: 10.1038/s41598-020-64406-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Accepted: 03/27/2020] [Indexed: 02/06/2023] Open
Abstract
Wearable sensors enable the monitoring of an individual’s sweat composition in real time. In this work, we recorded real-time sweat chloride concentration for 12 healthy subjects in three different protocols involving step changes in exercise load and compared the results to laboratory-based analysis. The sensor results reflected the changes in exercise load in real time. On increasing the exercise load from 100 W to 200 W the sweat chloride concentration increased from 12.0 ± 5.9 to 31.4 ± 16 mM (mean ± SD). On decreasing the load from 200 W to 100 W, the sweat chloride concentration decreased from 27.7 ± 10.5 to 14.8 ± 8.1 mM. The half-time associated with the change in sweat chloride, defined as the time at which the concentration reached half of the overall change, was about 6 minutes. While the changes in sweat chloride were statistically significant, there was no correlation with changes in sweat rate or other physiological parameters, which we attribute to intra-individual variation (SD = 1.6–8.1 mM). The response to exercise-induced sweating was significantly different to chemically-induced sweating where the sweat chloride concentration was almost independent of sweat rate. We speculate that this difference is related to changes in the open probability of the CFTR channel during exercise, resulting in a decrease in reabsorption efficiency at higher sweat rates.
Collapse
|
6
|
Choi DH, Kitchen GB, Jennings MT, Cutting GR, Searson PC. Out-of-clinic measurement of sweat chloride using a wearable sensor during low-intensity exercise. NPJ Digit Med 2020; 3:49. [PMID: 32258431 PMCID: PMC7101332 DOI: 10.1038/s41746-020-0257-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Accepted: 03/05/2020] [Indexed: 02/04/2023] Open
Abstract
Wearable sensors have the potential to enable measurement of sweat chloride outside the clinic. Here we assess the feasibility of mild exercise as an alternative to pilocarpine iontophoresis for sweat generation. The results from this proof-of-concept study suggest that mild exercise could be a feasible approach to obtain reliable measurements of sweat chloride concentration within 20-30 min using a wearable sensor.
Collapse
Affiliation(s)
- Dong-Hoon Choi
- Institute for Nanobiotechnology, John Hopkins University, Baltimore, MD USA
| | - Grant B. Kitchen
- Institute for Nanobiotechnology, John Hopkins University, Baltimore, MD USA
| | - Mark T. Jennings
- Department of Medicine, Division of Pulmonary and Critical Care, Johns Hopkins Hospital, Baltimore, MD USA
| | - Garry R. Cutting
- Institute of Genetic Medicine, Johns Hopkins University, Baltimore, MD USA
| | - Peter C. Searson
- Institute for Nanobiotechnology, John Hopkins University, Baltimore, MD USA
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, MD USA
| |
Collapse
|