1
|
Sterke B, Jabeen S, Baines P, Vallery H, Ribbers G, Heijenbrok-Kal M. Direct biomechanical manipulation of human gait stability: A systematic review. PLoS One 2024; 19:e0305564. [PMID: 38990959 PMCID: PMC11239080 DOI: 10.1371/journal.pone.0305564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Accepted: 05/31/2024] [Indexed: 07/13/2024] Open
Abstract
People fall more often when their gait stability is reduced. Gait stability can be directly manipulated by exerting forces or moments onto a person, ranging from simple walking sticks to complex wearable robotics. A systematic review of the literature was performed to determine: What is the level of evidence for different types of mechanical manipulations on improving gait stability? The study was registered at PROSPERO (CRD42020180631). Databases Embase, Medline All, Web of Science Core Collection, Cochrane Central Register of Controlled Trials, and Google Scholar were searched. The final search was conducted on the 1st of December, 2022. The included studies contained mechanical devices that influence gait stability for both impaired and non-impaired subjects. Studies performed with prosthetic devices, passive orthoses, and analysing post-training effects were excluded. An adapted NIH quality assessment tool was used to assess the study quality and risk of bias. Studies were grouped based on the type of device, point of application, and direction of forces and moments. For each device type, a best-evidence synthesis was performed to quantify the level of evidence based on the type of validity of the reported outcome measures and the study quality assessment score. Impaired and non-impaired study participants were considered separately. From a total of 4701 papers, 53 were included in our analysis. For impaired subjects, indicative evidence was found for medio-lateral pelvis stabilisation for improving gait stability, while limited evidence was found for hip joint assistance and canes. For non-impaired subjects, moderate evidence was found for medio-lateral pelvis stabilisation and limited evidence for body weight support. For all other device types, either indicative or insufficient evidence was found for improving gait stability. Our findings also highlight the lack of consensus on outcome measures amongst studies of devices focused on manipulating gait.
Collapse
Affiliation(s)
- Bram Sterke
- Rehabilitation Medicine, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Saher Jabeen
- Department of Biomechanical Engineering, Technical University of Delft, Delft, The Netherlands
| | - Patricia Baines
- Department of Biomechanical Engineering, Technical University of Delft, Delft, The Netherlands
| | - Heike Vallery
- Rehabilitation Medicine, Erasmus Medical Center, Rotterdam, The Netherlands
- Department of Biomechanical Engineering, Technical University of Delft, Delft, The Netherlands
| | - Gerard Ribbers
- Rehabilitation Medicine, Erasmus Medical Center, Rotterdam, The Netherlands
- Rijndam Rehabilitation Center, Rotterdam, The Netherlands
| | - Majanka Heijenbrok-Kal
- Rehabilitation Medicine, Erasmus Medical Center, Rotterdam, The Netherlands
- Rijndam Rehabilitation Center, Rotterdam, The Netherlands
| |
Collapse
|
2
|
Sterke BT, Poggensee KL, Ribbers GM, Lemus D, Vallery H. Light-Weight Wearable Gyroscopic Actuators Can Modulate Balance Performance and Gait Characteristics: A Proof-of-Concept Study. Healthcare (Basel) 2023; 11:2841. [PMID: 37957986 PMCID: PMC10647239 DOI: 10.3390/healthcare11212841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 10/13/2023] [Accepted: 10/24/2023] [Indexed: 11/15/2023] Open
Abstract
Falling is a major cause of morbidity, and is often caused by a decrease in postural stability. A key component of postural stability is whole-body centroidal angular momentum, which can be influenced by control moment gyroscopes. In this proof-of-concept study, we explore the influence of our wearable robotic gyroscopic actuator "GyroPack" on the balance performance and gait characteristics of non-impaired individuals (seven female/eight male, 30 ± 7 years, 68.8 ± 8.4 kg). Participants performed a series of balance and walking tasks with and without wearing the GyroPack. The device displayed various control modes, which were hypothesised to positively, negatively, or neutrally impact postural control. When configured as a damper, the GyroPack increased mediolateral standing time and walking distance, on a balance beam, and decreased trunk angular velocity variability, while walking on a treadmill. When configured as a negative damper, both peak trunk angular rate and trunk angular velocity variability increased during treadmill walking. This exploratory study shows that gyroscopic actuators can influence balance and gait kinematics. Our results mirror the findings of our earlier studies; though, with more than 50% mass reduction of the device, practical and clinical applicability now appears within reach.
Collapse
Affiliation(s)
- Bram T. Sterke
- Department of Rehabilitation Medicine, Erasmus Medical Center, 3015 GD Rotterdam, The Netherlands; (K.L.P.); (G.M.R.); (H.V.)
- Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, The Netherlands;
| | - Katherine L. Poggensee
- Department of Rehabilitation Medicine, Erasmus Medical Center, 3015 GD Rotterdam, The Netherlands; (K.L.P.); (G.M.R.); (H.V.)
- Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, The Netherlands;
| | - Gerard M. Ribbers
- Department of Rehabilitation Medicine, Erasmus Medical Center, 3015 GD Rotterdam, The Netherlands; (K.L.P.); (G.M.R.); (H.V.)
- Rijndam Revalidatie, Westersingel 300, 3015 LJ Rotterdam, The Netherlands
| | - Daniel Lemus
- Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, The Netherlands;
| | - Heike Vallery
- Department of Rehabilitation Medicine, Erasmus Medical Center, 3015 GD Rotterdam, The Netherlands; (K.L.P.); (G.M.R.); (H.V.)
- Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, The Netherlands;
- Faculty of Mechanical Engineering, Rhine-Westphalia Technical University of Aachen, 52062 Aachen, Germany
| |
Collapse
|
3
|
Baimyshev A, Finn-Henry M, Goldfarb M. A supervisory controller intended to arrest dynamic falls with a wearable cold-gas thruster. WEARABLE TECHNOLOGIES 2023; 4:e23. [PMID: 38510588 PMCID: PMC10952053 DOI: 10.1017/wtc.2023.18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 06/06/2023] [Accepted: 06/20/2023] [Indexed: 03/22/2024]
Abstract
This article examines the feasibility of employing a cold-gas thruster (CGT), intended as a backpack-wearable device, for purposes of arresting backward falls, and in particular describes a supervisory controller that, for some motion described by an arbitrary combination of center-of-mass angle and angular velocity, both detects an impending fall and determines when to initiate thrust in the CGT in order to arrest the impending fall. The CGT prototype and the supervisory controller are described and experimentally assessed using a rocking block apparatus intended to approximate a backward-falling human. In these experiments, the CGT and supervisory controller restored upright stability to the rocking block in all experiment cases that would have otherwise resulted in a fall without the CGT assistance. Since the controller and experiments employ a reduced-order model of a falling human, the authors also conducted a series of simulations intended to examine the extent to which the controller might remain effective in the case of a multi-segment human. The results of these simulations suggest that the CGT controller would be nearly as effective on a multi-segment falling human as on the reduced-order model.
Collapse
Affiliation(s)
| | | | - Michael Goldfarb
- School of Engineering, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|
4
|
Jabeen S, Baines PM, Harlaar J, Vallery H, Berry A. Reaction moments matter when designing lower-extremity robots for tripping recovery. PLoS One 2023; 18:e0280158. [PMID: 36809378 PMCID: PMC9942996 DOI: 10.1371/journal.pone.0280158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Accepted: 12/21/2022] [Indexed: 02/23/2023] Open
Abstract
Balance recovery after tripping often requires an active adaptation of foot placement. Thus far, few attempts have been made to actively assist forward foot placement for balance recovery employing wearable devices. This study aims to explore the possibilities of active forward foot placement through two paradigms of actuation: assistive moments exerted with the reaction moments either internal or external to the human body, namely 'joint' moments and 'free' moments, respectively. Both paradigms can be applied to manipulate the motion of segments of the body (e.g., the shank or thigh), but joint actuators also exert opposing reaction moments on neighbouring body segments, altering posture and potentially inhibiting tripping recovery. We therefore hypothesised that a free moment paradigm is more effective in assisting balance recovery following tripping. The simulation software SCONE was used to simulate gait and tripping over various ground-fixed obstacles during the early swing phase. To aid forward foot placement, joint moments and free moments were applied either on the thigh to augment hip flexion or on the shank to augment knee extension. Two realizations of joint moments on the hip were simulated, with the reaction moment applied to either the pelvis or the contralateral thigh. The simulation results show that assisting hip flexion with either actuation paradigm on the thigh can result in full recovery of gait with a margin of stability and leg kinematics closely matching the unperturbed case. However, when assisting knee extension with moments on the shank, free moment effectively assist balance but joint moments with the reaction moment on the thigh do not. For joint moments assisting hip flexion, placement of the reaction moment on the contralateral thigh was more effective in achieving the desired limb dynamics than placing the reaction on the pelvis. Poor choice of placement of reaction moments may therefore have detrimental consequences for balance recovery, and removing them entirely (i.e., free moment) could be a more effective and reliable alternative. These results challenge conventional assumptions and may inform the design and development of a new generation of minimalistic wearable devices to promote balance during gait.
Collapse
Affiliation(s)
- Saher Jabeen
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
| | - Patricia M. Baines
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
| | - Jaap Harlaar
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
- Department of Orthopedics, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Heike Vallery
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
- Department of Rehabilitation Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Andrew Berry
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
- Department of Rehabilitation Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
5
|
Abeywardena S, Anwar E, Miller S, Farkhatdinov I. Human balance augmentation via a supernumerary robotic tail. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:2878-2881. [PMID: 36086349 DOI: 10.1109/embc48229.2022.9871317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Humans are intrinsically unstable in quiet stance from a rigid body system viewpoint; however, they maintain balance thanks to neuro-muscular sensory properties whilst still exhibiting postural sway characteristics. This work intro-duces a one-degree-of-freedom supernumerary tail for balance augmentation in the sagittal plane to negate anterior-posterior postural sway. Simulations showed that the tail could success-fully balance a human with impaired ankle stiffness and neural control. Insights into tail design and control were made; namely, to minimise muscular load the tail must have a significant component in the direction of the muscle, mounting location of the tail is significant in maximising inertial properties for balance augmentation and that adaptive control of the tail will be best suited for different loads held by a wearer.
Collapse
|
6
|
Lee H, Eizad A, Park J, Kim Y, Hwang S, Oh MK, Yoon J. Development of a Novel 2-Dimensional Neck Haptic Device for Gait Balance Training. IEEE Robot Autom Lett 2022. [DOI: 10.1109/lra.2022.3143568] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|