1
|
Johny Dathees T, Narmatha G, Prabakaran G, Seenithurai S, Chai JD, Suresh Kumar R, Prabhu J, Nandhakumar R. Salicylaldehyde built fluorescent probe for dual sensing of Al 3+, Zn 2+ ions: Applications in latent fingerprint, bio-imaging & real sample analysis. Food Chem 2024; 441:138362. [PMID: 38219362 DOI: 10.1016/j.foodchem.2024.138362] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 12/23/2023] [Accepted: 01/03/2024] [Indexed: 01/16/2024]
Abstract
This Schiff base chemosensor (SNN) detected dual ions, Al3+ and Zn2+ ions selectively. Fluorescence spectrum investigations showed that Al3+ ions increased fluorescence intensity, notably at 493 nm. Introducing Zn2+ ions caused a significant blue shift of roughly ∼65 nm at a wavelength of 434 nm, resulting in a notable change in fluorescence intensity. When binding Al3+/Zn2+ ions, the SNN receptor uses three methods. Inhibition of photoinduced electron transfer (PET), excited state intramolecular proton transfer (ESIPT), and restriction of CN isomerization. The jobs plot method found that SNN + Al3+ and SNN + Zn2+ complexations had a 1:1 stoichiometry. DFT, LC-HRMS, and 1H NMR titration confirm this conclusion. The probe SNN's limit of detection (LOD) for Al3+/Zn2+ ions was 3.99 nM and 1.33 nM. Latent fingerprint (LFP), food samples, pharmaceutical products, and E. coli pathogen bio-imaging have all used the SNN probe to identify Al3+ and Zn2+ ions.
Collapse
Affiliation(s)
- T Johny Dathees
- Fluorensic Materials Lab, Division of Physical Science, Karunya Institute of Technology and Sciences, (Deemed-to-be University), Karunya Nagar, Coimbatore 641 114, India; PG and Research Center of Chemistry, Jayaraj Annapackiam College for Women (Autonomous), Periyakulam, 625 601 Theni, India
| | - G Narmatha
- Fluorensic Materials Lab, Division of Physical Science, Karunya Institute of Technology and Sciences, (Deemed-to-be University), Karunya Nagar, Coimbatore 641 114, India
| | - G Prabakaran
- Fluorensic Materials Lab, Division of Physical Science, Karunya Institute of Technology and Sciences, (Deemed-to-be University), Karunya Nagar, Coimbatore 641 114, India
| | - Sonai Seenithurai
- Department of Physics, National Taiwan University, Taipei 10617, Taiwan
| | - Jeng-Da Chai
- Department of Physics, National Taiwan University, Taipei 10617, Taiwan; Center for Theoretical Physics and Center for Quantum Science and Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - Raju Suresh Kumar
- Department of Chemistry, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
| | - J Prabhu
- Fluorensic Materials Lab, Division of Physical Science, Karunya Institute of Technology and Sciences, (Deemed-to-be University), Karunya Nagar, Coimbatore 641 114, India
| | - R Nandhakumar
- Fluorensic Materials Lab, Division of Physical Science, Karunya Institute of Technology and Sciences, (Deemed-to-be University), Karunya Nagar, Coimbatore 641 114, India.
| |
Collapse
|
2
|
Kim DM, Yoo SM. Colorimetric Systems for the Detection of Bacterial Contamination: Strategy and Applications. BIOSENSORS 2022; 12:bios12070532. [PMID: 35884335 PMCID: PMC9313054 DOI: 10.3390/bios12070532] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 07/10/2022] [Accepted: 07/13/2022] [Indexed: 12/19/2022]
Abstract
Bacterial contamination is a public health concern worldwide causing enormous social and economic losses. For early diagnosis and adequate management to prevent or treat pathogen-related illnesses, extensive effort has been put into the development of pathogenic bacterial detection systems. Colorimetric sensing systems have attracted increasing attention due to their simple and single-site operation, rapid signal readout with the naked eye, ability to operate without external instruments, portability, compact design, and low cost. In this article, recent trends and advances in colorimetric systems for the detection and monitoring of bacterial contamination are reviewed. This article focuses on pathogen detection strategies and technologies based on reaction factors that affect the color change for visual readout. Reactions used in each strategy are introduced by dividing them into the following five categories: external pH change-induced pH indicator reactions, intracellular enzyme-catalyzed chromogenic reactions, enzyme-like nanoparticle (NP)-catalyzed substrate reactions, NP aggregation-based reactions, and NP accumulation-based reactions. Some recently developed colorimetric systems are introduced, and their challenges and strategies to improve the sensing performance are discussed.
Collapse
Affiliation(s)
- Dong-Min Kim
- Center for Applied Life Science, Hanbat National University, Daejeon 34158, Korea;
| | - Seung-Min Yoo
- School of Integrative Engineering, Chung-Ang University, Seoul 06974, Korea
- Correspondence:
| |
Collapse
|
3
|
Ren B, Yu Y, Poopal RK, Qiao L, Ren B, Ren Z. IR-Based Novel Device for Real-Time Online Acquisition of Fish Heart ECG Signals. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:4262-4271. [PMID: 35258949 DOI: 10.1021/acs.est.1c07732] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
We developed an infrared (IR)-based real-time online monitoring device (US Patent No: US 10,571,448 B2) to quantify heart electrocardiogram (ECG) signals to assess the water quality based on physiological changes in fish. The device is compact, allowing us to monitor cardiac function for an extended period (from 7 to 30 days depending on the rechargeable battery capacity) without function injury and disturbance of swimming activity. The electrode samples and the biopotential amplifier and microcontroller process the cardiac-electrical signals. An infrared transceiver transmits denoised electrocardiac signals to complete the signal transmission. The infrared receiver array and biomedical acquisition signal processing system send signals to the computer. The software in the computer processes the data in real time. We quantified ECG indexes (P-wave, Q-wave, R-wave, S-wave, T-wave, PR-interval, QRS-complex, and QT-interval) of carp precisely and incessantly under the different experimental setup (CuSO4 and deltamethrin). The ECG cue responses were chemical-specific based on CuSO4 and deltamethrin exposures. This study provides an additional technology for noninvasive water quality surveillance.
Collapse
Affiliation(s)
- Baixiang Ren
- Institute of Environment and Ecology, Shandong Normal University, 250358 Jinan, China
| | - Yaxin Yu
- Institute of Environment and Ecology, Shandong Normal University, 250358 Jinan, China
| | - Rama-Krishnan Poopal
- Institute of Environment and Ecology, Shandong Normal University, 250358 Jinan, China
| | - Linlin Qiao
- Institute of Environment and Ecology, Shandong Normal University, 250358 Jinan, China
| | - Baichuan Ren
- Institute of Environment and Ecology, Shandong Normal University, 250358 Jinan, China
| | - Zongming Ren
- Institute of Environment and Ecology, Shandong Normal University, 250358 Jinan, China
| |
Collapse
|