1
|
Kono K, Tomita T, Yamazaki T, Inui H, Tanaka S, D'Lima DD. In Vivo Kinematics and Cruciate Ligament Tension Are Not Restored to Normal After Bicruciate-Preserving Arthroplasty. J Arthroplasty 2024; 39:S333-S339. [PMID: 38552864 DOI: 10.1016/j.arth.2024.03.060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 03/19/2024] [Accepted: 03/21/2024] [Indexed: 04/23/2024] Open
Abstract
BACKGROUND Whether cruciate ligament forces in cruciate-preserving designs, such as unicompartmental knee arthroplasty (UKA) or bi-cruciate-retaining total knee arthroplasty (BCR-TKA), differ from those in normal knees remains unknown. The purpose of this study was to compare the in vivo kinematics and cruciate ligament force in knees before and after UKA or BCR-TKA to those in normal knees during high-flexion activity. METHODS Overall, twenty normal knees, 17 knees with medial UKA, and 15 knees with BCR-TKA were fluoroscopically examined while performing a squatting activity. A 2-dimensional or 3-dimensional registration technique was employed to measure tibio-femoral kinematics. Ligament strains and tensions in the anteromedial bundle of the anterior cruciate ligament and posterolateral bundle of the anterior cruciate ligament and the anterolateral bundle of the posterior cruciate ligament (aPCL) and posteromedial bundle of the posterior cruciate ligament (pPCL) during knee flexion were analyzed. RESULTS Tension in both bundles of the anterior cruciate ligament decreased with flexion. At 60° of flexion, anteromedial bundle of the anterior cruciate ligament tension in postoperative UKA knees was greater than that in normal knees. At 30° of flexion, posterolateral bundle of the anterior cruciate ligament tension in postoperative UKA knees was greater than that in normal knees. On the other hand, aPCL and pPCL tensions increased with flexion. From 40 to 110° of flexion, the postoperative aPCL tension in UKA knees was greater than that in normal knees. At 110° of flexion, the preoperative pPCL tension in UKA knees was greater than that in normal knees. In addition, the postoperative pPCL tension in UKA knees was larger than that in normal knees beyond 20° of flexion. Furthermore, the pPCL tension of postoperative BCR-TKA knees was larger than that in normal knees from 20 to 50° and beyond 90° of flexion. CONCLUSIONS The cruciate ligament tensions, especially posterior cruciate ligament tension in knees after UKA, were greater than those in the normal knees. Surgeons performing bi-cruciat-preserving knee arthroplasties should therefore balance cruciate ligament tension more carefully in flexion and extension.
Collapse
Affiliation(s)
- Kenichi Kono
- Faculty of Medicine, Department of Orthopedic Surgery, The University of Tokyo, Tokyo, Japan; Department of Orthopedic Biomaterial Science, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Tetsuya Tomita
- Department of Orthopedic Biomaterial Science, Osaka University Graduate School of Medicine, Osaka, Japan; Department of Health Science, Graduate School of Health Science, Morinomiya University of Medical Sciences, Osaka, Japan
| | - Takaharu Yamazaki
- Faculty of Engineering, Department of Information Systems, Saitama Institute of Technology, Fukaya, Saitama, Japan
| | - Hiroshi Inui
- Faculty of Medicine, Department of Orthopedic Surgery, The University of Tokyo, Tokyo, Japan; Department of Orthopedic Surgery, Saitama Medical University, Saitama Medical Center, Kawagoe, Saitama, Japan
| | - Sakae Tanaka
- Faculty of Medicine, Department of Orthopedic Surgery, The University of Tokyo, Tokyo, Japan
| | - Darryl D D'Lima
- Shiley Center for Orthopaedic Research & Education, Scripps Health, La Jolla, California
| |
Collapse
|
2
|
Kono K, Konda S, Yamazaki T, Taketomi S, Yamagami R, Kawaguchi K, Kage T, Arakawa T, Inui H, Tanaka S, Tomita T. Comparison of finite helical axis of the knee joint before and after bi-cruciate-preserving knee arthroplasty. Clin Biomech (Bristol, Avon) 2023; 109:106098. [PMID: 37729737 DOI: 10.1016/j.clinbiomech.2023.106098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 07/13/2023] [Accepted: 09/12/2023] [Indexed: 09/22/2023]
Abstract
BACKGROUND Difference in the finite helical axis of the knee joints before and after anterior cruciate ligament-preserving knee arthroplasties such as unicompartmental knee arthroplasty and bi-cruciate-retaining total knee arthroplasty remains unknown. This study compared the knee finite helical axes before and after bi-cruciate-preserving knee arthroplasty. METHODS Patients undergoing medial unicompartmental knee arthroplasty and bi-cruciate-retaining total knee arthroplasty were included. Under fluoroscopy, participants performed a deep knee bend before and after surgery. A two/three-dimensional registration technique was employed to measure tibiofemoral kinematics. Femoral finite helical axis was calculated in a flexion range of 0-120° using 30° windows (early-, mid-, late-, and deep-flexion phases). FINDINGS In unicompartmental knee arthroplasty, the preoperative knee vertical angle was larger than the postoperative vertical angle in mid- and deep-flexion phases. The postoperative knee vertical angle was smaller in unicompartmental knee arthroplasty than in bi-cruciate-retaining total knee arthroplasty. In unicompartmental knee arthroplasty, the preoperative horizontal angle was smaller than the postoperative horizontal angle in the early-flexion phase. However, in bi-cruciate-retaining total knee arthroplasty, the preoperative horizontal angle was larger than the postoperative horizontal angle in mid- and deep-flexion phases. The horizontal angle was smaller before unicompartmental knee arthroplasty than that before bi-cruciate-retaining total knee arthroplasty in early-, mid-, and deep-flexion phases. However, the vertical angle was larger after unicompartmental knee arthroplasty than that after bi-cruciate-retaining total knee arthroplasty in the early-flexion phase. INTERPRETATION The knee finite helical axes before and after unicompartmental knee arthroplasty differed from those before and after bi-cruciate-retaining total knee arthroplasty.
Collapse
Affiliation(s)
- Kenichi Kono
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan; Department of Orthopaedic Biomaterial Science, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, Osaka, 565-0871, Japan.
| | - Shoji Konda
- Department of Health and Sport Sciences, Osaka University Graduate School of Medicine, 1-17 Machikaneyama, Toyonaka, Osaka 560-0043, Japan
| | - Takaharu Yamazaki
- Department of Information Systems, Saitama Institute of Technology, 1690 Fusaiji, Fukaya, Saitama, 369-0293, Japan
| | - Shuji Taketomi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Ryota Yamagami
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Kohei Kawaguchi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Tomofumi Kage
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Takahiro Arakawa
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Hiroshi Inui
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan; Saitama Medical University, Saitama Medical Center, 1981 Kamoda, Kawagoe City, Saitama 350-8500, Japan
| | - Sakae Tanaka
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Tetsuya Tomita
- Department of Orthopaedic Biomaterial Science, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, Osaka, 565-0871, Japan; Master Course of Health Sciences, Graduate School of Health Sciences, Morinomiya University of Medical Sciences, 1-26-16 Nankokita, Suminoe, Osaka, Osaka 559-8611, Japan
| |
Collapse
|
3
|
Kono K, Inui H, Tomita T, Yamazaki T, Konda S, Taketomi S, Tanaka S, D'Lima DD. Bicruciate-retaining total knee arthroplasty procedure reduced tensile force in the middle and posterior components of lateral collateral ligament during deep knee flexion activities with no effect on tensile force of the medial collateral ligament. Knee Surg Sports Traumatol Arthrosc 2023; 31:3889-3897. [PMID: 36928366 DOI: 10.1007/s00167-023-07342-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Accepted: 02/05/2023] [Indexed: 03/18/2023]
Abstract
PURPOSE To analyse the effects of bicruciate-retaining total knee arthroplasty (BCR-TKA) on the tensile force of the collateral ligaments during two deep knee flexion activities, cross-leg sitting and squatting. METHODS Thirteen patients (15 knees) treated using bicruciate-retaining total knee arthroplasty (BCR-TKA) for knee joint osteoarthritis were analysed. Knee joint kinematics during cross-leg sitting (open-chain flexion) and squatting (closed-chain flexion) were evaluated through fluoroscopy. The tensile force was calculated in vivo based on the change in the distance between the femoral and tibial attachment areas for the anterior, middle, and posterior components of the superficial (sMCL) and deep (dMCL) medial collateral ligament and the lateral collateral ligament (LCL). Differences in the calculated tensile forces of the collateral ligaments were evaluated using repeated measures of analysis of variance, with post hoc pairwise comparison (Bonferroni test). Statistical significance was set at P ≤ 0.05. RESULTS The correction of the coronal alignment was related to the surgical technique, not to the implant design. No significant change in the tensile force in all three components of the sMCL from pre- to post-TKA (n.s.) was observed. For dMCL, a pre- to post-TKA change in the tensile force was observed only for the anterior dMCL component (p = 0.03). No change was observed in the tensile force of the anterior LCL with increasing flexion, with no difference in pre- to post-TKA and between activities (n.s.). In contrast, tensile force in the middle LCL slightly decreased with increasing flexion during squatting, pre- and post-TKA. After surgery, lower forces were generated at 40° of flexion (p = 0.04). Tensile force in the posterior LCL was higher in extension than flexion, which remained high in the extension post-TKA. However, after surgery, lower tensile forces were generated at 10° (p = 0.04) and 40° (p = 0.04) of flexion. CONCLUSIONS The in vivo change in tensile forces of the collateral ligaments of the knee before and after BCR-TKA can inform the development of appropriate ligament balancing strategies to facilitate recovery of deep knee flexion activities after TKA, as well as for continued improvement of BCR-TKA designs. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Kenichi Kono
- Department of Molecular Medicine Arthritis Research, The Scripps Research Institute, La Jolla, CA, USA
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Hiroshi Inui
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
| | - Tetsuya Tomita
- Department of Orthopaedic Biomaterial Science, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
- Master Course of Health Sciences, Graduate School of Health Sciences, Morinomiya University of Medical Sciences, Osaka, Japan
| | - Takaharu Yamazaki
- Department of Information Systems, Faculty of Engineering, Saitama Institute of T1echnology, Fukaya, Saitama, Japan
| | - Shoji Konda
- Department of Health and Sport Sciences, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Shuji Taketomi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Sakae Tanaka
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Darryl D D'Lima
- Department of Molecular Medicine Arthritis Research, The Scripps Research Institute, La Jolla, CA, USA
- Shiley Center for Orthopaedic Research & Education at Scripps Clinic, La Jolla, CA, USA
| |
Collapse
|
4
|
Lu HY, Lin CC, Shih KS, Lu TW, Kuo MY, Li SY, Hsu HC. Integration of statistical shape modeling and alternating interpolation-based model tracking technique for measuring knee kinematics in vivo using clinical interleaved bi-plane fluoroscopy. PeerJ 2023; 11:e15371. [PMID: 37334125 PMCID: PMC10276557 DOI: 10.7717/peerj.15371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 04/18/2023] [Indexed: 06/20/2023] Open
Abstract
Background A 2D fluoroscopy/3D model-based registration with statistical shape modeling (SSM)-reconstructed subject-specific bone models will help reduce radiation exposure for 3D kinematic measurements of the knee using clinical alternating bi-plane fluoroscopy systems. The current study aimed to develop such an approach and evaluate in vivo its accuracy and identify the effects of the accuracy of SSM models on the kinematic measurements. Methods An alternating interpolation-based model tracking (AIMT) approach with SSM-reconstructed subject-specific bone models was used for measuring 3D knee kinematics from dynamic alternating bi-plane fluoroscopy images. A two-phase optimization scheme was used to reconstruct subject-specific knee models from a CT-based SSM database of 60 knees using one, two, or three pairs of fluoroscopy images. Using the CT-reconstructed model as a benchmark, the performance of the AIMT with SSM-reconstructed models in measuring bone and joint kinematics during dynamic activity was evaluated in terms of mean target registration errors (mmTRE) for registered bone poses and the mean absolute differences (MAD) for each motion component of the joint poses. Results The mmTRE of the femur and tibia for one image pair were significantly greater than those for two and three image pairs without significant differences between two and three image pairs. The MAD was 1.16 to 1.22° for rotations and 1.18 to 1.22 mm for translations using one image pair. The corresponding values for two and three image pairs were 0.75 to 0.89° and 0.75 to 0.79 mm; and 0.57 to 0.79° and 0.6 to 0.69 mm, respectively. The MAD values for one image pair were significantly greater than those for two and three image pairs without significant differences between two and three image pairs. Conclusions An AIMT approach with SSM-reconstructed models was developed, enabling the registration of interleaved fluoroscopy images and SSM-reconstructed models from more than one asynchronous fluoroscopy image pair. This new approach had sub-millimeter and sub-degree measurement accuracy when using more than one image pair, comparable to the accuracy of CT-based methods. This approach will be helpful for future kinematic measurements of the knee with reduced radiation exposure using 3D fluoroscopy with clinically alternating bi-plane fluoroscopy systems.
Collapse
Affiliation(s)
- Hsuan-Yu Lu
- Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan, R.O.C.
| | - Cheng-Chung Lin
- Department of Electrical Engineering, Fu-Jen Catholic University, New Taipei, Taiwan, R.O.C.
| | - Kao-Shang Shih
- Department of Orthopedics, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan, R.O.C.
| | - Tung-Wu Lu
- Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan, R.O.C.
- Department of Orthopaedic Surgery, School of Medicine, National Taiwan University, Taipei, Taiwan, R.O.C.
| | - Mei-Ying Kuo
- Department of Physical Therapy, China Medical University, Taichung, Taiwan, R.O.C.
| | - Song-Ying Li
- Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan, R.O.C.
| | - Horng-Chaung Hsu
- Department of Orthopaedic Surgery, China Medical University, Taichung, Taiwan, R.O.C.
| |
Collapse
|
5
|
Effect of weight-bearing in bicruciate-retaining total knee arthroplasty during high-flexion activities. Clin Biomech (Bristol, Avon) 2022; 92:105569. [PMID: 34998082 DOI: 10.1016/j.clinbiomech.2021.105569] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 12/30/2021] [Accepted: 12/30/2021] [Indexed: 02/07/2023]
Abstract
BACKGROUND To evaluate the effect of weight-bearing on the kinematics of the bicruciate-retaining total knee arthroplasty design during high knee flexion activities. METHODS The kinematics of 21 bicruciate-retaining total knee arthroplasties were evaluated under fluoroscopy, with two- and three-dimensional image registrations, during squatting (weight-bearing) and active-assisted knee flexion (non-weight-bearing). The following variables were measured: knee range of motion, axis of femoral rotation and varus-valgus angle relative to the tibial component, anteroposterior translation of the medial and lateral contact points, and the kinematic pathway of the joint surfaces. FINDINGS From 20° to 100° of flexion, the femoral external rotation during weight-bearing was larger than that during non-weight-bearing. There were no differences in the varus-valgus angles between the two conditions. From 10° to 50° of flexion, the medial contact point during weight-bearing was located posterior to the point of contact during non-weight-bearing; this difference between the two weight-bearing conditions was significant. From 0° to 90° of flexion, the lateral contact point in weight-bearing was located posterior to the contact point in non-weight-bearing; this difference between the two weight-bearing conditions was also significant. INTERPRETATION The anteroposterior position of the medial and lateral contact points of the bicruciate-retaining total knee arthroplasty design was significantly more posterior in the mid-range of knee flexion in weight-bearing than in non-weight-bearing. However, no anterior translation of the bicruciate-retaining total knee arthroplasty design was observed. Therefore, bicruciate-retaining total knee arthroplasty appears to have good anteroposterior stability throughout the range of knee flexion, regardless of the weight-bearing condition.
Collapse
|
6
|
Kono K, Inui H, Tomita T, D'Lima DD, Yamazaki T, Konda S, Taketomi S, Yamagami R, Kawaguchi K, Sameshima S, Kage T, Tanaka S. Cruciate ligament force of knees following mobile-bearing unicompartmental knee arthroplasty is larger than the preoperative value. Sci Rep 2021; 11:18233. [PMID: 34521921 PMCID: PMC8440682 DOI: 10.1038/s41598-021-97655-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2021] [Accepted: 08/20/2021] [Indexed: 11/29/2022] Open
Abstract
We analyzed the implantation effects on cruciate ligament force in unicompartmental knee arthroplasty (UKA) and determined whether kinematics is associated with the cruciate ligament force. We examined 16 patients (17 knees) undergoing medial UKA. Under fluoroscopy, each participant performed a deep knee bend before and after UKA. A two-dimensional/three-dimensional registration technique was employed to measure tibiofemoral kinematics. Forces in the anteromedial and posterolateral bundles of both the anterior cruciate ligament (aACL and pACL) and the anterolateral and posteromedial bundles of the posterior cruciate ligament (aPCL and pPCL) during knee flexion were analyzed pre- and post-UKA. Correlations between changes in kinematics and ligament forces post-UKA were also analyzed. Preoperatively, the aACL forces were highly correlated with anteroposterior (AP) translation of the lateral condyles (Correlation coefficient [r] = 0.59). The pPCL forces were highly correlated with the varus–valgus angulation (r = − 0.57). However, postoperatively, the PCL forces in both bundles were highly correlated with the AP translation of the medial femoral condyle (aPCL: r = 0.62, pPCL: r = 0.60). The ACL and PCL forces of the knees post-UKA were larger than those of the knees pre-UKA. Kinematic changes were significantly correlated with the cruciate ligament force changes.
Collapse
Affiliation(s)
- Kenichi Kono
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Hiroshi Inui
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan.
| | - Tetsuya Tomita
- Department of Orthopaedic Biomaterial Science, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, Osaka, 565-0871, Japan
| | - Darryl D D'Lima
- Department of Molecular Medicine Arthritis Research, The Scripps Research Institute, La Jolla, CA, 92037, USA.,Shiley Center for Orthopaedic Research & Education at Scripps Clinic, La Jolla, CA, 92121, USA
| | - Takaharu Yamazaki
- Department of Information Systems, Faculty of Engineering, Saitama Institute of Technology, 1690 Fusaiji, Fukaya, Saitama, 369-0293, Japan
| | - Shoji Konda
- Department of Health and Sport Sciences, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, Osaka, 565-0871, Japan
| | - Shuji Taketomi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Ryota Yamagami
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Kohei Kawaguchi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Shin Sameshima
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Tomofumi Kage
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Sakae Tanaka
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| |
Collapse
|