1
|
Chen-Yoshikawa TF. Evolution of Three-Dimensional Computed Tomography Imaging in Thoracic Surgery. Cancers (Basel) 2024; 16:2161. [PMID: 38893279 PMCID: PMC11172068 DOI: 10.3390/cancers16112161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2024] [Revised: 05/31/2024] [Accepted: 06/05/2024] [Indexed: 06/21/2024] Open
Abstract
Radiologic reconstruction technology allows the wide use of three-dimensional (3D) computed tomography (CT) images in thoracic surgery. A minimally invasive surgery has become one of the standard therapies in thoracic surgery, and therefore, the need for preoperative and intraoperative simulations has increased. Three-dimensional CT images have been extensively used, and various types of software have been developed to reconstruct 3D-CT images for surgical simulation worldwide. Several software types have been commercialized and widely used by not only radiologists and technicians, but also thoracic surgeons. Three-dimensional CT images are helpful surgical guides; however, in almost all cases, they provide only static images, different from the intraoperative views. Lungs are soft and variable organs that can easily change shape by intraoperative inflation/deflation and surgical procedures. To address this issue, we have developed a novel software called the Resection Process Map (RPM), which creates variable virtual 3D images. Herein, we introduce the RPM and its development by tracking the history of 3D CT imaging in thoracic surgery. The RPM could help develop a real-time and accurate surgical navigation system for thoracic surgery.
Collapse
|
2
|
Tsai AY, Greene AC. 3D printing in pediatric surgery. Semin Pediatr Surg 2024; 33:151385. [PMID: 38242062 DOI: 10.1016/j.sempedsurg.2024.151385] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2024]
Abstract
Pediatric surgery presents a unique challenge, requiring a specialized approach due to the intricacies of compact anatomy and the presence of distinct congenital features in young patients. Surgeons are tasked with making decisions that not only address immediate concerns but also consider the evolving needs of children as they grow. The advent of three-dimensional (3D) printing has emerged as a valuable tool to facilitate a personalized medical approach. This paper starts by outlining the basics of 3D modeling and printing. We then delve into the transformative role of 3D printing in pediatric surgery, elucidating its applications, benefits, and challenges. The paper concludes by envisioning the future prospects of 3D printing, foreseeing advancements in personalized treatment approaches, improved patient outcomes, and the continued evolution of this technology as an indispensable asset in the pediatric surgical arena.
Collapse
Affiliation(s)
- Anthony Y Tsai
- Division of Pediatric Surgery, Assistant Professor of Surgery and Pediatrics, Penn State Children's Hospital, 500 University Drive, Hershey, PA 17033, United States.
| | - Alicia C Greene
- Division of Pediatric Surgery, Assistant Professor of Surgery and Pediatrics, Penn State Children's Hospital, 500 University Drive, Hershey, PA 17033, United States
| |
Collapse
|
3
|
Ock J, Hong D, Moon S, Park YS, Seo DW, Yoon JH, Kim SH, Kim N. An interactive and realistic phantom for cricothyroidotomy simulation of a patient with obesity through a reusable design using 3D-printing and Arduino. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 233:107478. [PMID: 36965301 DOI: 10.1016/j.cmpb.2023.107478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 03/08/2023] [Accepted: 03/10/2023] [Indexed: 06/18/2023]
Abstract
BACKGROUND AND OBJECTIVES Proper airway management during emergencies can prevent serious complications. However, cricothyroidotomy is challenging in patients with obesity. Since this technique is not performed frequently but at a critical time, the opportunity for trainees is rare. Simulators for these procedures are also lacking. Therefore, we proposed a realistic and interactive cricothyroidotomy simulator. METHODS All anatomical structures were modeled based on computed tomography images of a patient with obesity. To mimic the feeling of incision during cricothyroidotomy, the incision site was modeled to distinguish between the skin and fat. To reinforce the educational purpose, capacitive touch sensors were attached to the artery, vein, and thyroid to generate audio feedback. The tensile strength of the silicone-cast skin was measured to verify the similarity of the mechanical properties between humans and our model. The fabrication and assembly accuracies of the phantom between the Standard Tessellation Language and the fabricated model were evaluated. Audio feedback through sensing the anatomy parts and utilization was evaluated. RESULTS The body, skull, clavicle, artery, vein, and thyroid were fabricated using fused deposition modeling (FDM) with polylactic acid. A skin mold was fabricated using FDM with thermoplastic polyurethane. A fat mold was fabricated using stereolithography apparatus (SLA) with a clear resin. The airway and tongue were fabricated using SLA with an elastic resin. The tensile strength of the skin using silicone with and without polyester mesh was 2.63 ± 0.68 and 2.46 ± 0.21 MPa. The measurement errors for fabricating and assembling parts of the phantom between the STL and the fabricated models were -0.08 ± 0.19 mm and 0.13 ± 0.64 mm. The measurement errors internal anatomy embodied surfaces in fat part were 0.41 ± 0.89 mm. Audio feedback was generated 100% in all the areas tested. The realism, understanding of clinical skills, and intention to retrain were 7.1, 8.8, and 8.3 average points. CONCLUSIONS Our simulator can provide a realistic simulation experience for trainees through a realistic feeling of incision and audio feedback, which can be used for actual clinical education.
Collapse
Affiliation(s)
- Junhyeok Ock
- Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-Ro 43-Gil Songpa-Gu, Seoul 05505, Republic of Korea
| | - Dayeong Hong
- Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-Ro 43-Gil Songpa-Gu, Seoul 05505, Republic of Korea
| | - Sojin Moon
- Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-Ro 43-Gil Songpa-Gu, Seoul 05505, Republic of Korea
| | - Yong-Seok Park
- Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, 388-1 Pungnap2-dong, 88 Olympic-Ro 43-Gil, Songpa-gu, Seoul 05505, Republic of Korea
| | - Dong-Woo Seo
- Department of Emergency Medicine, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, Republic of Korea
| | - Joo Heung Yoon
- Division of Pulmonary, Allergy, and Critical Care Medicine, School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA
| | - Sung-Hoon Kim
- Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, 388-1 Pungnap2-dong, 88 Olympic-Ro 43-Gil, Songpa-gu, Seoul 05505, Republic of Korea.
| | - Namkug Kim
- Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-Ro 43-Gil Songpa-Gu, Seoul 05505, Republic of Korea; Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, Republic of Korea.
| |
Collapse
|
4
|
A High-Fidelity Artificial Urological System for the Quantitative Assessment of Endoscopic Skills. J Funct Biomater 2022; 13:jfb13040301. [PMID: 36547561 PMCID: PMC9784860 DOI: 10.3390/jfb13040301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Revised: 12/07/2022] [Accepted: 12/13/2022] [Indexed: 12/23/2022] Open
Abstract
Minimally-invasive surgery is rapidly growing and has become a standard approach for many operations. However, it requires intensive practice to achieve competency. The current training often relies on animal organ models or physical organ phantoms, which do not offer realistic surgical scenes or useful real-time feedback for surgeons to improve their skills. Furthermore, the objective quantitative assessment of endoscopic skills is also lacking. Here, we report a high-fidelity artificial urological system that allows realistic simulation of endourological procedures and offers a quantitative assessment of the surgical performance. The physical organ model was fabricated by 3D printing and two-step polymer molding with the use of human CT data. The system resembles the human upper urinary tract with a high-resolution anatomical shape and vascular patterns. During surgical simulation, endoscopic videos are acquired and analyzed to quantitatively evaluate performance skills by a customized computer algorithm. Experimental results show significant differences in the performance between professional surgeons and trainees. The surgical simulator offers a unique chance to train endourological procedures in a realistic and safe environment, and it may also lead to a quantitative standard to evaluate endoscopic skills.
Collapse
|
5
|
Chen Y, Ding JL, Babaiasl M, Yang F, Swensen JP. Characterization and modeling of a thermoplastic elastomer tissue simulant under uniaxial compression loading for a wide range of strain rates. J Mech Behav Biomed Mater 2022; 131:105218. [DOI: 10.1016/j.jmbbm.2022.105218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Revised: 03/04/2022] [Accepted: 04/02/2022] [Indexed: 11/16/2022]
|
6
|
Berti F, Antonini L, Poletti G, Fiuza C, Vaughan TJ, Migliavacca F, Petrini L, Pennati G. How to Validate in silico Deployment of Coronary Stents: Strategies and Limitations in the Choice of Comparator. FRONTIERS IN MEDICAL TECHNOLOGY 2022; 3:702656. [PMID: 35047942 PMCID: PMC8757815 DOI: 10.3389/fmedt.2021.702656] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Accepted: 07/01/2021] [Indexed: 11/13/2022] Open
Abstract
This study aims at proposing and discussing useful indications to all those who need to validate a numerical model of coronary stent deployment. The proof of the reliability of a numerical model is becoming of paramount importance in the era of in silico trials. Recently, the ASME V&V Standard Committee for medical devices prepared the V&V 40 standard document that provides a framework that guides users in establishing and assessing the relevance and adequacy of verification and validation activities performed for proving the credibility of models. To the knowledge of the authors, only a few examples of the application of the V&V 40 framework to medical devices are available in the literature, but none about stents. Specifically, in this study, the authors wish to emphasize the choice of a relevant set of experimental activities to provide data for the validation of computational models aiming to predict coronary stent deployment. Attention is focused on the use of ad hoc 3D-printed mock vessels in the validation plan, which could allow evaluating aspects of clinical relevance in a representative but controlled environment.
Collapse
Affiliation(s)
- Francesca Berti
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Luca Antonini
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Gianluca Poletti
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Constantino Fiuza
- Biomechanics Research Center (BioMEC), Biomedical Engineering, School of Engineering, College of Science and Engineering, National University of Ireland Galway, Galway, Ireland
| | - Ted J Vaughan
- Biomechanics Research Center (BioMEC), Biomedical Engineering, School of Engineering, College of Science and Engineering, National University of Ireland Galway, Galway, Ireland
| | - Francesco Migliavacca
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Lorenza Petrini
- Department of Civil and Environmental Engineering, Politecnico di Milano, Milan, Italy
| | - Giancarlo Pennati
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| |
Collapse
|