1
|
Yang D, Li X, Li X, Chen J, Zhang T, Lian T, Wang H. Design and synthesis of nano-iron oxyhydroxide-based molecularly imprinted electrochemical sensors for trace-level carbendazim detection in actual samples. Mikrochim Acta 2024; 191:163. [PMID: 38413431 DOI: 10.1007/s00604-024-06236-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 01/24/2024] [Indexed: 02/29/2024]
Abstract
Carbendazim (CBD) is widely used as a fungicide that acts as a pesticide in farming to prevent crop diseases. However, CBD can remain on crops for a long time. When consumed by humans and animals, it produces a range of toxic symptoms and poses a serious threat to their health. Therefore, the detection of CBD is necessary. Traditional assay strategies for CBD detection, although sensitive and practical, can hardly achieve fast, robust monitoring during food processing and daily life. Here, we designed a novel electrochemical sensor for CBD detection. In this method, iron oxyhydroxide nanomaterial (β-FeOOH) was first prepared by hydrothermal method. Then, a molecularly imprinted polymer (MIP) layer was electropolymerized on the surface using CBD as the template and resorcinol (RC) as the functional monomer. The synergistic interaction between β-FeOOH and MIP endows the MIP/β-FeOOH/CC-based electrochemical sensor with high specificity and sensitivity. Under optimal conditions, the MIP/β-FeOOH/CC-based sensor showed a wide linear range of 39 pM-80 nM for CBD and a detection limit as low as 25 pM. Therefore, the as-prepared sensor can be a practical and effective tool for pesticide residue detection.
Collapse
Affiliation(s)
- Dong Yang
- College of Chemistry and Chemical Engineering, Shaanxi University of Science & Technology, Xi'an, 710021, China.
- Xi'an Key Laboratory of Advanced Performance Materials and Polymers, Shaanxi University of Science & Technology, Xi'an, 710021, China.
- Key Laboratory of Chemical Additives for China National Light Industry, Xi'an, 710021, China.
| | - Xuhua Li
- College of Chemistry and Chemical Engineering, Shaanxi University of Science & Technology, Xi'an, 710021, China
- Xi'an Key Laboratory of Advanced Performance Materials and Polymers, Shaanxi University of Science & Technology, Xi'an, 710021, China
- Key Laboratory of Chemical Additives for China National Light Industry, Xi'an, 710021, China
| | - Xiangyu Li
- College of Chemistry and Chemical Engineering, Shaanxi University of Science & Technology, Xi'an, 710021, China
- Xi'an Key Laboratory of Advanced Performance Materials and Polymers, Shaanxi University of Science & Technology, Xi'an, 710021, China
- Key Laboratory of Chemical Additives for China National Light Industry, Xi'an, 710021, China
| | - Jifan Chen
- College of Chemistry and Chemical Engineering, Shaanxi University of Science & Technology, Xi'an, 710021, China
- Xi'an Key Laboratory of Advanced Performance Materials and Polymers, Shaanxi University of Science & Technology, Xi'an, 710021, China
- Key Laboratory of Chemical Additives for China National Light Industry, Xi'an, 710021, China
| | - Ting Zhang
- College of Chemistry and Chemical Engineering, Shaanxi University of Science & Technology, Xi'an, 710021, China
- Xi'an Key Laboratory of Advanced Performance Materials and Polymers, Shaanxi University of Science & Technology, Xi'an, 710021, China
- Key Laboratory of Chemical Additives for China National Light Industry, Xi'an, 710021, China
| | - Ting Lian
- School of Clinical Medicine, Xi'an Medical University, Xi'an, 710021, China
| | - Haihua Wang
- College of Chemistry and Chemical Engineering, Shaanxi University of Science & Technology, Xi'an, 710021, China.
- Xi'an Key Laboratory of Advanced Performance Materials and Polymers, Shaanxi University of Science & Technology, Xi'an, 710021, China.
- Key Laboratory of Chemical Additives for China National Light Industry, Xi'an, 710021, China.
| |
Collapse
|
2
|
Eldeeb MA, Dhamu VN, Paul A, Muthukumar S, Prasad S. Espial: Electrochemical Soil pH Sensor for In Situ Real-Time Monitoring. MICROMACHINES 2023; 14:2188. [PMID: 38138357 PMCID: PMC10745296 DOI: 10.3390/mi14122188] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 11/24/2023] [Accepted: 11/29/2023] [Indexed: 12/24/2023]
Abstract
We present a first-of-its-kind electrochemical sensor that demonstrates direct real-time continuous soil pH measurement without any soil pre-treatment. The sensor functionality, performance, and in-soil dynamics have been reported. The sensor coating is a composite matrix of alizarin and Nafion applied by drop casting onto the working electrode. Electrochemical impedance spectroscopy (EIS) and squarewave voltammetry (SWV) studies were conducted to demonstrate the functionality of each method in accurately detecting soil pH. The studies were conducted on three different soil textures (clay, sandy loam, and loamy clay) to cover the range of the soil texture triangle. Squarewave voltammetry showed pH-dependent responses regardless of soil texture (while electrochemical impedance spectroscopy's pH detection range was limited and dependent on soil texture). The linear models showed a sensitivity range from -50 mV/pH up to -66 mV/pH with R2 > 0.97 for the various soil textures in the pH range 3-9. The validation of the sensor showed less than a 10% error rate between the measured pH and reference pH for multiple different soil textures including ones that were not used in the calibration of the sensor. A 7-day in situ soil study showed the capability of the sensor to measure soil pH in a temporally dynamic manner with an error rate of less than 10%. The test was conducted using acidic and alkaline soils with pH values of 5.05 and 8.36, respectively.
Collapse
Affiliation(s)
- Mohammed A. Eldeeb
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA
| | | | - Anirban Paul
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA
| | | | - Shalini Prasad
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA
| |
Collapse
|
3
|
Timpel J, Klinghammer S, Riemenschneider L, Ibarlucea B, Cuniberti G, Hannig C, Sterzenbach T. Sensors for in situ monitoring of oral and dental health parameters in saliva. Clin Oral Investig 2023; 27:5719-5736. [PMID: 37698630 PMCID: PMC10560166 DOI: 10.1007/s00784-023-05206-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 08/11/2023] [Indexed: 09/13/2023]
Abstract
OBJECTIVES The oral cavity is an easily accessible unique environment and open system which is influenced by the oral fluids, microbiota, and nutrition. Little is known about the kinetics and dynamics of metabolic processes at the intraoral surfaces. Real-time monitoring of salivary biomarkers, e.g., glucose, lactate, fluoride, calcium, phosphate, and pH with intraoral sensors is therefore of major interest. The aim of this review is to overview the existing literature for intraoral saliva sensors. MATERIALS AND METHODS A comprehensive literature search was performed to review the most relevant studies on intraoral saliva sensor technology. RESULTS There is limited literature about the in situ saliva monitoring of salivary biomarkers. Bioadhesion and biofouling processes at the intraoral surfaces limit the performances of the sensors. Real-time, long-term, and continuous intraoral measurement of salivary metabolites remains challenging and needs further investigation as only few well-functioning sensors have been developed until today. Until now, there is no sensor that measures reliably beyond hours for any analyte other than glucose. CONCLUSIONS Saliva's complex and dynamic structure as well as bioadhesion are key challenges and should be addressed in the future developments. Consequently, more studies that focus particularly on biofouling processes and interferential effects of the salivary matrix components on sensor surfaces are required. CLINICAL RELEVANCE By monitoring fluids in the oral cavity, as the entrance to the digestive system, extensive information can be obtained regarding the effects of foods and preventive agents on the oral microbiota and the tooth surfaces. This may lead to a better understanding of strategies to modulate oral and general health.
Collapse
Affiliation(s)
- Julia Timpel
- Clinic of Operative and Pediatric Dentistry, Medical Faculty Carl Gustav Carus, Dresden University of Technology, Fetscherstraße 74, 01307, Dresden, Germany.
- Else Kröner-Fresenius Center for Digital Health (EKFZ), Dresden University of Technology, 01309, Dresden, Germany.
| | - Stephanie Klinghammer
- Else Kröner-Fresenius Center for Digital Health (EKFZ), Dresden University of Technology, 01309, Dresden, Germany
- Institute for Materials Science and Max Bergmann Center for Biomaterials, Dresden University of Technology, 01069, Dresden, Germany
| | - Leif Riemenschneider
- Else Kröner-Fresenius Center for Digital Health (EKFZ), Dresden University of Technology, 01309, Dresden, Germany
- Institute for Materials Science and Max Bergmann Center for Biomaterials, Dresden University of Technology, 01069, Dresden, Germany
| | - Bergoi Ibarlucea
- Else Kröner-Fresenius Center for Digital Health (EKFZ), Dresden University of Technology, 01309, Dresden, Germany
- Institute for Materials Science and Max Bergmann Center for Biomaterials, Dresden University of Technology, 01069, Dresden, Germany
| | - Gianaurelio Cuniberti
- Else Kröner-Fresenius Center for Digital Health (EKFZ), Dresden University of Technology, 01309, Dresden, Germany
- Institute for Materials Science and Max Bergmann Center for Biomaterials, Dresden University of Technology, 01069, Dresden, Germany
| | - Christian Hannig
- Clinic of Operative and Pediatric Dentistry, Medical Faculty Carl Gustav Carus, Dresden University of Technology, Fetscherstraße 74, 01307, Dresden, Germany
- Else Kröner-Fresenius Center for Digital Health (EKFZ), Dresden University of Technology, 01309, Dresden, Germany
| | - Torsten Sterzenbach
- Clinic of Operative and Pediatric Dentistry, Medical Faculty Carl Gustav Carus, Dresden University of Technology, Fetscherstraße 74, 01307, Dresden, Germany
- Else Kröner-Fresenius Center for Digital Health (EKFZ), Dresden University of Technology, 01309, Dresden, Germany
| |
Collapse
|
4
|
McCann C, Gilpin V, Scott C, Pourshahidi LK, Gill CIR, Davis J. Moving towards in pouch diagnostics for ostomy patients: exploiting the versatility of laser induced graphene sensors. JOURNAL OF MATERIALS SCIENCE 2023; 58:14207-14219. [PMID: 37745186 PMCID: PMC10511578 DOI: 10.1007/s10853-023-08881-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Accepted: 08/18/2023] [Indexed: 09/26/2023]
Abstract
The development of a 3D printed sensor for direct incorporation within stoma pouches is described. Laser induced graphene scribed on either side of polyimide film served as the basis of a 2 electrode configuration that could be integrated within a disposable pouch sensor for the periodic monitoring of ileostomy fluid pH. The graphene sensors were characterised using electron microscopy, Raman spectroscopy, DekTak profilometry with the electrochemical properties investigated using both cyclic and square wave voltammetry. Adsorbed riboflavin was employed as a biocompatible redox probe for the voltammetric measurement of pH. The variation in peak position with pH was found to be linear over pH 3-8 with a sub Nernstian response (43 mV/pH). The adsorbed probe was found to be reversible and exhibited minimal leaching through repeated scanning. The performance of the system was assessed in a heterogeneous bacterial fermentation mixture simulating ileostomy fluid with the pH recorded before and after 96 h incubation. The peak profile in the bacterial medium provided an unambiguous signal free from interference with the calculated pH before and after incubation (pH 5.3 to 3.66) in good agreement with that obtained with commercial pH probes. Graphical abstract Supplementary Information The online version contains supplementary material available at 10.1007/s10853-023-08881-x.
Collapse
Affiliation(s)
- Conor McCann
- School of Engineering, Ulster University, Belfast, Northern Ireland
| | - Victoria Gilpin
- School of Engineering, Ulster University, Belfast, Northern Ireland
| | - Cameron Scott
- School of Engineering, Ulster University, Belfast, Northern Ireland
| | | | - Chris. I. R. Gill
- School of Biomedical Sciences, Ulster University, Coleraine, Northern Ireland
| | - James Davis
- School of Engineering, Ulster University, Belfast, Northern Ireland
| |
Collapse
|
5
|
Dinesh B, Saravanan N, Kumar AS. New Strategy for Improved Conductivity and Redox-Enhanced Supercapacitor Performance of Nickel Metal-Organic Framework. CHEMICAL ENGINEERING JOURNAL ADVANCES 2022. [DOI: 10.1016/j.ceja.2022.100311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|