Xu G, Wang Q, Li Z, Wu T. Computed tomography Osteoabsorptiometry: Review of bone density, mechanical strength of material and clinical application. Front Bioeng Biotechnol 2023; 11:1066709. [PMID: 37051272 PMCID: PMC10083511 DOI: 10.3389/fbioe.2023.1066709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Accepted: 03/10/2023] [Indexed: 03/29/2023] Open
Abstract
Computed Tomography (CT) imaging is an effective non-invasive examination. It is widely used in the diagnosis of fractures, arthritis, tumor, and some anatomical characteristics of patients. The density value (Hounsfield unit, HU) of a material in computed tomography can be the same for materials with varying elemental compositions. This value depends on the mass density of the material and the degree of X-ray attenuation. Computed Tomography Osteoabsorptiometry (CTOAM) imaging technology is developed on the basis of CT imaging technology. By applying pseudo-color image processing to the articular surface, it is used to analyze the distribution of bone mineralization under the articular cartilage, evaluate the position of prosthesis implantation, track the progression of osteoarthritis, and determine the joint injury prognosis. Furthermore, this technique was combined with indentation testing to discuss the relationship between the high bone density area of the articular surface, the mechanical strength of the bone, and the anchorage stability of the implant, in addition to the study of the relationship between mechanical strength and bone density. This narrative study discusses the pre- and postoperative evaluation of medical device implantation position, orthopedic surgery, and the clinical treatment of bone injury and degeneration. It also discusses the research status of CTOAM technology in image post-processing engineering and the relationship between bone material and mechanical strength.
Collapse
Affiliation(s)
- Guanghua Xu
- Orthopedic Center, Affiliated Hospital of Guangdong Medical University, Zhanjiang, China
- Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, Guangdong Provincial Key Laboratory of Medical Biomechanics, National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China
- Institute of Sport and Exercise Medicine, North University of China, Taiyuan, China
| | - Qiuyuan Wang
- Graduate School of Beijing University of Chinese Medicine, Beijing, China
| | - Zhiqiang Li
- School of Physical Education, North University of China, Taiyuan, China
| | - Tingrui Wu
- Orthopedic Center, Affiliated Hospital of Guangdong Medical University, Zhanjiang, China
- *Correspondence: Tingrui Wu,
| |
Collapse
|