1
|
Angelini A, D’Amico A, Paolilli S, Signori R, Baldin G, Di Rubbo G, Denaro L, Ruggieri P. Electrochemotherapy in Spine Metastases: A Case Series Focused on Technical Aspects, Surgical Strategies and Results. Diagnostics (Basel) 2024; 14:936. [PMID: 38732352 PMCID: PMC11083160 DOI: 10.3390/diagnostics14090936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Revised: 04/28/2024] [Accepted: 04/29/2024] [Indexed: 05/13/2024] Open
Abstract
Metastases are complications of primary tumors due to prolonged cancer survival and have become an important issue for oncological patients and the most frequent cause of death and disability. Bone metastases occur at a later stage of cancer disease, and the spine is the most frequent site. To date, the aim of the treatment of metastases remains to be the control of disease and provide a satisfactory quality of life. The decision making of treatment is influenced by several factors such as the status of the primary disease, the number of metastases, site involvement, and the performance status of the patients. For this reason, the treatment of metastases is challenging and undergoes constant development. Therefore, alternative techniques with respect to surgery, which is the first option but not always practicable, and radiochemotherapy are attractive. Lately, electrochemotherapy has emerged as an innovative method for treating various primary and metastatic solid tumors, showing promising outcomes in terms of inducing tumor tissue necrosis and alleviating symptoms. This technique uses electric pulses to increase the uptake of chemotherapy by tumor cells. Despite the initial enthusiasm and good results in the treatment of bone tumors, relatively few papers have described its use in spine metastases. Therefore, we conducted a systemic review of this intriguing topic while also reporting our experience in the use of electrochemotherapy for the treatment of spine metastases.
Collapse
Affiliation(s)
- Andrea Angelini
- Department of Orthopedics and Traumatology and Oncological Orthopedics, University of Padova, Via Giustiniani, 35128 Padova, Italy; (S.P.); (R.S.); (G.B.); (G.D.R.); (P.R.)
| | - Alberto D’Amico
- Academic Neurosurgery Department of Neurosciences, University of Padova, 35128 Padova, Italy; (A.D.); (L.D.)
| | - Stefania Paolilli
- Department of Orthopedics and Traumatology and Oncological Orthopedics, University of Padova, Via Giustiniani, 35128 Padova, Italy; (S.P.); (R.S.); (G.B.); (G.D.R.); (P.R.)
| | - Riccardo Signori
- Department of Orthopedics and Traumatology and Oncological Orthopedics, University of Padova, Via Giustiniani, 35128 Padova, Italy; (S.P.); (R.S.); (G.B.); (G.D.R.); (P.R.)
| | - Giovanni Baldin
- Department of Orthopedics and Traumatology and Oncological Orthopedics, University of Padova, Via Giustiniani, 35128 Padova, Italy; (S.P.); (R.S.); (G.B.); (G.D.R.); (P.R.)
| | - Giuseppe Di Rubbo
- Department of Orthopedics and Traumatology and Oncological Orthopedics, University of Padova, Via Giustiniani, 35128 Padova, Italy; (S.P.); (R.S.); (G.B.); (G.D.R.); (P.R.)
| | - Luca Denaro
- Academic Neurosurgery Department of Neurosciences, University of Padova, 35128 Padova, Italy; (A.D.); (L.D.)
| | - Pietro Ruggieri
- Department of Orthopedics and Traumatology and Oncological Orthopedics, University of Padova, Via Giustiniani, 35128 Padova, Italy; (S.P.); (R.S.); (G.B.); (G.D.R.); (P.R.)
| |
Collapse
|
2
|
Lopes LB, Pintarelli GB, Guedert R, Andrade DLLS, Antonio AC, Ramos CTS, da Silva JR, Rangel MMM, Suzuki DOH. Novel tetrapolar single-needle electrode for electrochemotherapy in bone cavities: Modeling, design and validation. Med Eng Phys 2024; 125:104120. [PMID: 38508798 DOI: 10.1016/j.medengphy.2024.104120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 01/12/2024] [Accepted: 02/14/2024] [Indexed: 03/22/2024]
Abstract
Electrochemotherapy is a cancer treatment in which local pulsed electric fields are delivered through electrodes. The effectiveness of the treatment depends on exposing the tumor to a threshold electric field. Electrode geometry plays an important role in the resulting electric field distribution, especially in hard-to-reach areas and deep-seated tumors. We designed and developed a novel tetrapolar single-needle electrode for proper treatment in bone cavities. In silico and in vitro experiments were performed to evaluate the electric field and electric current produced by the electrode. In addition, tomography images of a real case of nasal cavity tumor were segmented into a 3D simulation to evaluate the electrode performance in a bone cavity. The proposed electrode was validated and its operating range was set up to 650 V. In the nasal cavity tumor, we found that the electrode can produce a circular electric field of 3 mm with an electric current of 14.1 A at 500 V, which is compatible with electrochemotherapy standards and commercial equipment.
Collapse
Affiliation(s)
- Lucas B Lopes
- Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianópolis, 88040-900, SC, Brazil.
| | - Guilherme B Pintarelli
- Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianópolis, 88040-900, SC, Brazil; Department of Control and Automation Engineering, Federal University of Santa Catarina, Blumenau, 89036-004, SC, Brazil
| | - Raul Guedert
- Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianópolis, 88040-900, SC, Brazil
| | - Daniella L L S Andrade
- Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianópolis, 88040-900, SC, Brazil
| | - Afrânio C Antonio
- Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianópolis, 88040-900, SC, Brazil
| | - Clara T S Ramos
- Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianópolis, 88040-900, SC, Brazil
| | - Jéssica R da Silva
- Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianópolis, 88040-900, SC, Brazil
| | | | - Daniela O H Suzuki
- Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianópolis, 88040-900, SC, Brazil
| |
Collapse
|
3
|
Guedert R, Andrade DLLS, Pintarelli GB, Suzuki DOH. Biological dispersion in the time domain using finite element method software. Sci Rep 2023; 13:22868. [PMID: 38129500 PMCID: PMC10739869 DOI: 10.1038/s41598-023-49828-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Accepted: 12/12/2023] [Indexed: 12/23/2023] Open
Abstract
Biological tissue exhibits a strong dielectric dispersion from DC to GHz. Implementing biological dispersion in the time domain with commercial finite element method software could help improve engineering analysis of electrical transient phenomena. This article describes the steps required to implement time-domain biological dispersion with commercial finite element method software. The study begins with the presentation of a genetic algorithm to fit the experimental dispersion curve of Solanum tuberosum (potato tuber) to multipoles of first-order Debye dispersion. The results show that it is possible to represent the biological dispersion of S. tuberosum from 40 Hz to 10 MHz in a 4-pole Debye dispersion. Then, a set of auxiliary differential equations is used to transform the multipole Debye dispersion from the frequency domain to the time domain. The equations are implemented in the commercial software COMSOL Multiphysics. A comparison between the frequency and time domain simulations was used to validate the method. An analysis of the electric current with square-wave pulsed voltage was performed. We found that the computer implementation proposed in this work can describe the biological dispersion and predict the electric current.
Collapse
Affiliation(s)
- Raul Guedert
- Department of Electrical and Electronic Engineering, Centre of Technology, Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianopolis, 88040-900, Brazil.
| | - Daniella L L S Andrade
- Department of Electrical and Electronic Engineering, Centre of Technology, Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianopolis, 88040-900, Brazil
| | - Guilherme B Pintarelli
- Department of Control, Automation and Computer Engineering, Federal University of Santa Catarina, Blumenau, 89036-256, Brazil
| | - Daniela O H Suzuki
- Department of Electrical and Electronic Engineering, Centre of Technology, Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianopolis, 88040-900, Brazil
| |
Collapse
|
4
|
Andrade DLLS, Pintarelli GB, Rosa JV, Paro IB, Pagano PJT, Silva JCN, Suzuki DOH. Musa acuminata as electroporation model. Bioelectrochemistry 2023; 154:108549. [PMID: 37639773 DOI: 10.1016/j.bioelechem.2023.108549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 08/17/2023] [Accepted: 08/19/2023] [Indexed: 08/31/2023]
Abstract
Electrochemotherapy (ECT) and Irreversible electroporation (IRE) are cancer treatments based on electric field distribution in tissues. Solanum tuberosum (potato tissue) phantom is known to mimic changes in the electrical conductivity that occur in animal tissues during electroporation (EP). Electric field distribution is assessed through enzymatic staining. However, the 24-h wait for this assessment could slow agile response scenarios. We developed and validated the Musa acuminata (cavendish banana) conductivity model, which quickly evaluates EP by tissue staining. We investigated the frequency response of the tissue using impedance spectroscopy analysis, conductivity changes, and enzymatic staining. We optimized three usual EP models: adapted Gompertz, smoothed Heaviside, and the sigmoid or logistic function. We found dielectric parameters in banana tissue similar to those in potato (electrical conductivity of 0.035 S/m and relative permittivity of 4.1×104). The coefficients of determination R2 were 99.94% (Gompertz), 99.85% (Heaviside), and 99.58% (sigmoid). The sigmoid and Heaviside functions described the calibration and validation electric currents with 95% confidence. We observed the electroporated areas in bananas 3h30m after EP. Staining was significant after 450 V/cm. The conductivity model of Musa acuminata suits treatment planning, hardware development, and training scenarios. Banana phantom supports the 3Rs practice and is a reliable alternative for potato in EP studies.
Collapse
Affiliation(s)
- Daniella L L S Andrade
- Institute of Biomedical Engineering, Department of Electrical and Electronics Engineering, Federal University of Santa Catarina, Florianópolis, SC, Brazil
| | - Guilherme B Pintarelli
- Department of Control and Automation Engineering, Federal University of Santa Catarina, Blumenau, SC, Brazil
| | - Juliana V Rosa
- Institute of Biomedical Engineering, Department of Electrical and Electronics Engineering, Federal University of Santa Catarina, Florianópolis, SC, Brazil
| | - Isabela B Paro
- Institute of Biomedical Engineering, Department of Electrical and Electronics Engineering, Federal University of Santa Catarina, Florianópolis, SC, Brazil
| | - Pedro J T Pagano
- Institute of Biomedical Engineering, Department of Electrical and Electronics Engineering, Federal University of Santa Catarina, Florianópolis, SC, Brazil
| | - Julia C N Silva
- Institute of Biomedical Engineering, Department of Electrical and Electronics Engineering, Federal University of Santa Catarina, Florianópolis, SC, Brazil
| | - Daniela O H Suzuki
- Institute of Biomedical Engineering, Department of Electrical and Electronics Engineering, Federal University of Santa Catarina, Florianópolis, SC, Brazil
| |
Collapse
|