1
|
Ott M, Singh N, Bauland F, Köppl D, Kandler K, Gaudl A, Geistanger A, Ceglarek U, Rauh M, Geletneky C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of cortisol in human serum and plasma. Clin Chem Lab Med 2025:cclm-2024-0879. [PMID: 39920882 DOI: 10.1515/cclm-2024-0879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2024] [Accepted: 01/02/2025] [Indexed: 02/09/2025]
Abstract
OBJECTIVES Accurate measurement of serum cortisol is crucial for the diagnosis and management of adrenal disorders. Thus, we have developed a novel isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC MS/MS)-based candidate reference measurement procedure (RMP) to quantify cortisol in human serum/plasma, offering higher sensitivity and reliability compared to existing RMPs. METHODS Quantitative Nuclear Magnetic Resonance spectroscopic (qNMR) methodology has been utilized to assign the absolute content (g/g) and SI-traceability to the reference materials. A novel two-dimensional heart-cut liquid chromatography (LC) approach was implemented for the LC-MS/MS, combined with a supported liquid extraction (SLE) sample preparation protocol. A multi-day validation experiment assessed precision and accuracy. Reproducibility was assessed by comparing procedure results between two independent laboratories, and measurement uncertainty (MU) was evaluated in compliance with current guidelines. RESULTS The established RMP exhibited high sensitivity, with a quantification range of 0.800-600 ng/mL (2.21-1,655 nmol/L), exceeding the ranges of existing JCTLM-listed RMPs. Intermediate precision was ≤2.6 %, and repeatability ranged from 0.9 to 1.9 % across all concentration levels. The relative mean bias ranged from -1.3 to 1.4 % for all matrices and concentration levels. Measurement uncertainties (MU) for cortisol in single measurements were ≤2.8 % regardless of the concentration level and sample type. Using the certified International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference panel, the equivalence between the candidate RMP and the Joint Committee on Traceability in Laboratory Medicine (JCTLM) listed RMPs (NRMeth 57 and NRMeth 8) was assessed, revealing excellent agreement. CONCLUSIONS This RMP allows for highly sensitive and reproducible determination of cortisol. The performance of the RMP facilitates the standardization of routine assays and ensures traceability in the measurement of individual patient samples.
Collapse
Affiliation(s)
- Myriam Ott
- Roche Diagnostics GmbH, Penzberg, Germany
| | | | | | - Daniel Köppl
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Erlangen, Germany
| | | | - Alexander Gaudl
- Institute of Laboratory Medicine, Clinical Chemistry and Molecular Diagnostics, University of Leipzig Medical Center, Leipzig, Germany
| | | | - Uta Ceglarek
- Institute of Laboratory Medicine, Clinical Chemistry and Molecular Diagnostics, University of Leipzig Medical Center, Leipzig, Germany
| | - Manfred Rauh
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Erlangen, Germany
| | | | | |
Collapse
|
2
|
Schierscher T, Salzmann L, Singh N, Bachmann M, Bauland F, Geistanger A, Risch L, Geletneky C, Seger C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of carbamazepine in human serum and plasma. Clin Chem Lab Med 2024; 62:1301-1313. [PMID: 38095314 DOI: 10.1515/cclm-2023-0943] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 11/14/2023] [Indexed: 05/30/2024]
Abstract
OBJECTIVES An isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) was developed and validated to accurately measure serum and plasma concentrations of carbamazepine. METHODS Quantitative nuclear magnetic resonance (qNMR) spectroscopy was used to determine the absolute content of the reference material, ensuring its traceability to SI units. The separation of carbamazepine from potential interferences, whether known or unknown, was achieved using a C18 column. A protein precipitation protocol followed by a high dilution step was established for sample preparation. Assay validation and determination of measurement uncertainty were performed in accordance with the guidelines of the Clinical and Laboratory Standards Institute, the International Conference on Harmonization (ICH), and the Guide to the Expression of Uncertainty in Measurement (GUM). In order to demonstrate equivalence to the already existing RMP a method comparison study was performed. RESULTS The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of carbamazepine within the range of 0.800-18.0 μg/mL. Intermediate precision and repeatability (n=60 measurements) was found to be <1.6 % and <1.3 % over all concentration levels and independent from the matrix. The relative mean bias ranged from -0.1 to 0.6 % for native serum and from -0.3 to -0.1 % for Li-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment were found to be <1.8 % and <1.3 %, respectively. Method comparison showed a good agreement between the Joint Committee of Traceability in Laboratory Medicine (JCTLM) listed RMP and the candidate RMP resulting in a Passing-Bablok regression equation with a slope of 1.01 and an intercept of -0.01. The bias in the patient cohort was found to be 0.9 %. CONCLUSIONS We present a novel LC-MS/MS-based candidate RMP for carbamazepine in human serum and plasma which provides a traceable and reliable platform for the standardization of routine assays and evaluation of clinically relevant samples.
Collapse
|
3
|
Schierscher T, Salzmann L, Singh N, Fischer V, Kobel A, Bauland F, Geistanger A, Risch L, Geletneky C, Seger C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of primidone in human serum and plasma. Clin Chem Lab Med 2024; 62:1327-1338. [PMID: 38549258 DOI: 10.1515/cclm-2023-1032] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Accepted: 03/12/2024] [Indexed: 05/30/2024]
Abstract
OBJECTIVES Primidone is an anticonvulsive drug used in the treatment of epilepsy and essential tremor. It offers beneficial effects in controlling seizures, but its usage is also associated with possible side effects. To ensure optimal therapy, it is crucial to measure its concentration through accurate quantification methods. Therefore, our main goal was to develop and validate a new reference measurement procedure (RMP) for accurately measuring primidone levels in human serum and plasma. METHODS In our study, we focused on the separation of primidone from both known and unknown interferences using a C18 column. To achieve accurate sample preparation, we developed a protocol involving protein precipitation followed by a high dilution step. The validation of the assay and determination of measurement uncertainty were carried out following guidelines from organizations such as the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. These rigorous validation processes ensure the reliability and accuracy of our method for quantifying primidone levels in human serum and plasma samples. RESULTS The RMP was shown to be highly selective and specific, with no evidence of matrix interference. It can be used to quantify primidone in the range of 0.150-30.0 μg/mL. Intermediate precision was less than 4.0 %, and repeatability CV ranged from 1.0 to 3.3 % across all concentration levels. The relative mean bias ranged from 0.1 to 3.9 % for native serum levels, and from -2.6 to 2.8 % for lithium-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment were 1.5-4.1 % and 0.9-1.0 %, respectively. CONCLUSIONS In this study, we introduce an innovative LC-MS/MS-based candidate RMP specifically designed for primidone in human serum and plasma. Our RMP offers a traceable platform, facilitating the standardization of routine assays and enabling the evaluation of clinically relevant samples. With this novel approach, we aim to enhance the accuracy and reliability of primidone measurements, ultimately benefiting the field of clinical research and patient care.
Collapse
Affiliation(s)
| | | | | | | | - Anja Kobel
- Dr. Risch Ostschweiz AG, Buchs, Switzerland
| | | | | | | | | | | | | |
Collapse
|
4
|
Schierscher T, Singh N, Kobel A, Wild J, Bauland F, Geistanger A, Risch L, Geletneky C, Seger C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of carbamazepine-10,11-epoxide in human serum and plasma. Clin Chem Lab Med 2024; 62:1339-1351. [PMID: 38515344 DOI: 10.1515/cclm-2023-1045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Accepted: 02/29/2024] [Indexed: 03/23/2024]
Abstract
OBJECTIVES A reference measurement procedure (RMP) using isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) was developed and validated with the aim of accurately measuring carbamazepine-10,11-epoxide concentrations in human serum and plasma. METHODS To establish traceability to SI units, the absolute content of the reference material was determined using quantitative nuclear magnetic resonance (qNMR) spectroscopy. As sample preparation a protein precipitation protocol followed by a high dilution step was established. Chromatographic separation from carbamazepine and potential metabolites was achieved using a C18 stationary phase. Selectivity, specificity, matrix effects, precision and accuracy, inter-laboratory equivalence, and uncertainty of measurement were evaluated based on guidelines from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. RESULTS The RMP demonstrated very good selectivity and specificity, showing no evidence of a matrix effect. This enabled accurate quantification of carbamazepine-epoxide in the concentration range of 0.0400-12.0 μg/mL. The intermediate precision was found to be less than 2.1 %, and the repeatability coefficient of variation (CV) ranged from 1.2 to 1.8 % across all concentration levels. Regarding accuracy, the relative mean bias varied from 1.4 to 2.5 % for native serum levels and from 1.4 to 3.5 % for Li-heparin plasma levels. The measurement uncertainty for single measurements ranged from 1.6 to 2.1 %. CONCLUSIONS In this study, we introduce a new LC-MS/MS-based candidate RMP for accurately measuring carbamazepine-10,11-epoxide in human serum and plasma. This novel method offers a traceable and dependable platform, making it suitable for standardizing routine assays and assessing clinically relevant samples.
Collapse
Affiliation(s)
| | - Neeraj Singh
- 111618 Roche Diagnostics GmbH , Penzberg, Germany
| | - Anja Kobel
- 58117 Dr. Risch Ostschweiz AG , Buchs, Switzerland
| | - Janik Wild
- 58117 Dr. Risch Ostschweiz AG , Buchs, Switzerland
| | | | | | - Lorenz Risch
- 58117 Dr. Risch Ostschweiz AG , Buchs, Switzerland
| | | | | | | |
Collapse
|
5
|
Seger C, Kessler A, Taibon J. Establishing metrological traceability for small molecule measurands in laboratory medicine. Clin Chem Lab Med 2023; 61:1890-1901. [PMID: 36622091 DOI: 10.1515/cclm-2022-0995] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 12/14/2022] [Indexed: 01/10/2023]
Abstract
For molecules that can be well described metrologically in the sense of the definition of measurands, and which can also be recorded analytically as individual substances, reference measurement service traceability to a metrologically sound foundation is a necessity. The establishment of traceability chains must be initiated by National Metrology Institutes (NMIs) according to applicable standards; they are at the top and leading position in this concept. If NMIs are not in the position to take up this task, alternative approaches must be sought. Traceability initiatives established by in vitro device industry or academia must meet the quality standards of NMIs. Adherence to International Organization for Standardization (ISO) procedure 15193 must be a matter of course for the establishment of reference measurement procedures (RMPs). Certified reference material (CRM) characterization must be thorough, e.g., by the application of quantitative nuclear magnetic resonance measurements and by adherence to ISO 15194. Both for RMPs and CRMs Joint Committee for Traceability in Laboratory Medicine (JCTLM) listing must be the ultimate goal. Results must be shared in a transparent manner to allow other stakeholders including NMIs to reproduce and disseminate the reference measurement procedures.
Collapse
Affiliation(s)
- Christoph Seger
- Labordiagnostic St. Gallen West AG, St. Gallen, Switzerland
- Institute of Pharmacy, CCB - Centrum of Chemistry and Biomedicine, CMBI - Center for Molecular Biosciences, University of Innsbruck, Innsbruck, Austria
| | - Anja Kessler
- Stiftung für Pathobiochemie und Molekulare Diagnostik, Bonn, Germany
| | | |
Collapse
|
6
|
Kobel A, Schierscher T, Singh N, Salzmann L, Liesch F, Bauland F, Geistanger A, Risch L, Geletneky C, Seger C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of levetiracetam in human serum and plasma. Clin Chem Lab Med 2023; 61:1967-1977. [PMID: 37011038 DOI: 10.1515/cclm-2022-1038] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Accepted: 03/14/2023] [Indexed: 04/04/2023]
Abstract
OBJECTIVES To develop an isotope dilution-liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based candidate reference measurement procedure (RMP) for levetiracetam quantification in human serum and plasma. METHODS Quantitative nuclear magnetic resonance spectroscopy (qNMR) was used to characterize the RMP material to ensure traceability to SI units. To quantify levetiracetam, an LC-MS/MS method was optimized using a C8 column for chromatographic separation following protein-precipitation-based sample preparation. Spiked matrix samples of serum and plasma were used to test selectivity and specificity. Matrix effects were determined by performing a post-column infusion experiment and comparing standard line slopes. Precision and accuracy were evaluated over 5 days. Measurement uncertainty was evaluated according to the Guide to the Expression of Uncertainty in Measurement (GUM). RESULTS The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of levetiracetam within the range of 1.53-90.0 μg/mL. Intermediate precision was <2.2% and repeatability was 1.1-1.7% across all concentrations. The relative mean bias ranged from -2.5% to -0.3% across all levels and matrices within the measuring range. Diluted samples were found with a mean bias ranging from -0.1 to 2.9%. The predefined acceptance criterion for measurement uncertainty was met and determined for individual measurements independently of the concentration level and sample type to be ≤4.0% (k=2). CONCLUSIONS We present a novel LC-MS/MS)-based candidate RMP for levetiracetam in human serum and plasma. Its expanded measurement uncertainty of ≤4.0% meets the clinical needs in levetiracetam monitoring. Utilizing qNMR to characterize levetiracetam reference materials allowed metrological traceability to SI units.
Collapse
Affiliation(s)
- Anja Kobel
- Dr. Risch Ostschweiz AG, Buchs, Switzerland
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Salzmann L, Wild J, Singh N, Schierscher T, Liesch F, Bauland F, Geistanger A, Risch L, Geletneky C, Seger C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of gabapentin in human serum and plasma. Clin Chem Lab Med 2023; 61:1955-1966. [PMID: 36689915 DOI: 10.1515/cclm-2022-0998] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 12/23/2022] [Indexed: 01/24/2023]
Abstract
OBJECTIVES To describe and validate a reference measurement procedure (RMP) for gabapentin, employing quantitative nuclear magnetic resonance (qNMR) spectroscopy to determine the absolute content of the standard materials in combination with isotope dilution-liquid chromatograph-tandem mass spectrometry (ID-LC-MS/MS) to accurately measure serum and plasma concentrations. METHODS A sample preparation protocol based on protein precipitation in combination with LC-MS/MS analysis using a C8 column for chromatographic separation was established for the quantification of gabapentin. Assay validation and determination of measurement uncertainty were performed according to guidance from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the expression of uncertainty in measurement. ID-LC-MS/MS parameters evaluated included selectivity, specificity, matrix effects, precision and accuracy, inter-laboratory equivalence, and uncertainty of measurement. RESULTS The use of qNMR provided traceability to International System (SI) units. The chromatographic assay was highly selective, allowing baseline separation of gabapentin and the gabapentin-lactam impurity, without observable matrix effects. Variability between injections, preparations, calibrations, and days (intermediate precision) was <2.3%, independent of the matrix, while the coefficient of variation for repeatability was 0.9-2.0% across all concentration levels. The relative mean bias ranged from -0.8-1.0% for serum and plasma samples. Passing-Bablok regression analysis indicated very good inter-laboratory agreement; the slope was 1.00 (95% confidence interval [CI] 0.98 to 1.03) and the intercept was -0.05 (95% CI -0.14 to 0.03). Pearson's correlation coefficient was ≥0.996. Expanded measurement uncertainties for single measurements were found to be ≤5.0% (k=2). CONCLUSIONS This analytical protocol for gabapentin, utilizing traceable and selective qNMR and ID-LC-MS/MS techniques, allows for the standardization of routine tests and the reliable evaluation of clinical samples.
Collapse
Affiliation(s)
| | - Janik Wild
- Dr. Risch Ostschweiz AG, Buchs, Switzerland
| | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Engel A, Ruhe L, Singh N, Wright JA, Liesch F, Bauland F, Ostermann AI, Sumalowitsch T, Schweinsberg VJT, Geistanger A, Hegel JK, Geletneky C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of methotrexate in human serum and plasma. Clin Chem Lab Med 2023; 61:1917-1929. [PMID: 36788118 DOI: 10.1515/cclm-2022-1001] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 02/03/2023] [Indexed: 02/16/2023]
Abstract
OBJECTIVES To develop an isotope dilution-liquid chromatography-tandem mass spectrometry-(ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for quantification of methotrexate in human serum and plasma. METHODS Quantitative nuclear magnetic resonance (qNMR) was used to determine absolute methotrexate content in the standard. Separation was achieved on a biphenyl reversed-phase analytical column with mobile phases based on water and acetonitrile, both containing 0.1% formic acid. Sample preparation included protein precipitation in combination with high sample dilution, and method validation according to current guidelines. The following were assessed: selectivity (using analyte-spiked samples, and relevant structural-related compounds and interferences); specificity and matrix effects (via post-column infusion and comparison of human matrix vs. neat samples); precision and accuracy (in a five-day validation analysis). RMP results were compared between two independent laboratories. Measurement uncertainty was evaluated according to current guidelines. RESULTS The RMP separated methotrexate from potentially interfering compounds and enabled measurement over a calibration range of 7.200-5,700 ng/mL (0.01584-12.54 μmol/L), with no evidence of matrix effects. All pre-defined acceptance criteria were met; intermediate precision was ≤4.3% and repeatability 1.5-2.1% for all analyte concentrations. Bias was -3.0 to 2.1% for samples within the measuring range and 0.8-4.5% for diluted samples, independent of the sample matrix. RMP results equivalence was demonstrated between two independent laboratories (Pearson correlation coefficient 0.997). Expanded measurement uncertainty of target value-assigned samples was ≤3.4%. CONCLUSIONS This ID-LC-MS/MS-based approach provides a candidate RMP for methotrexate quantification. Traceability of methotrexate standard and the LC-MS/MS platform were assured by qNMR assessment and extensive method validation.
Collapse
Affiliation(s)
- Anett Engel
- Department of Studies, Collaborations and Innovation Management, Labor Berlin - Charité Vivantes Services GmbH, Berlin, Germany
| | - Lena Ruhe
- Department of Studies, Collaborations and Innovation Management, Labor Berlin - Charité Vivantes Services GmbH, Berlin, Germany
| | | | | | | | | | - Annika I Ostermann
- Department of Studies, Collaborations and Innovation Management, Labor Berlin - Charité Vivantes Services GmbH, Berlin, Germany
| | - Tamara Sumalowitsch
- Department of Studies, Collaborations and Innovation Management, Labor Berlin - Charité Vivantes Services GmbH, Berlin, Germany
| | - Vincent J T Schweinsberg
- Department of Laboratory Medicine and Toxicology, Labor Berlin - Charité Vivantes GmbH, Berlin, Germany
| | | | - Johannes Kolja Hegel
- Department of Studies, Collaborations and Innovation Management, Labor Berlin - Charité Vivantes Services GmbH, Berlin, Germany
| | | | | |
Collapse
|