Li J, Chu H, Chen Z, Yiu CK, Qu Q, Li Z, Yu X. Recent Advances in Materials, Devices and Algorithms Toward Wearable Continuous Blood Pressure Monitoring. ACS NANO 2024; 18:17407-17438. [PMID: 38923501 DOI: 10.1021/acsnano.4c04291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/28/2024]
Abstract
Continuous blood pressure (BP) tracking provides valuable insights into the health condition and functionality of the heart, arteries, and overall circulatory system of humans. The rapid development in flexible and wearable electronics has significantly accelerated the advancement of wearable BP monitoring technologies. However, several persistent challenges, including limited sensing capabilities and stability of flexible sensors, poor interfacial stability between sensors and skin, and low accuracy in BP estimation, have hindered the progress in wearable BP monitoring. To address these challenges, comprehensive innovations in materials design, device development, system optimization, and modeling have been pursued to improve the overall performance of wearable BP monitoring systems. In this review, we highlight the latest advancements in flexible and wearable systems toward continuous noninvasive BP tracking with a primary focus on materials development, device design, system integration, and theoretical algorithms. Existing challenges, potential solutions, and further research directions are also discussed to provide theoretical and technical guidance for the development of future wearable systems in continuous ambulatory BP measurement with enhanced sensing capability, robustness, and long-term accuracy.
Collapse
Affiliation(s)
- Jian Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Hongwei Chu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Shenzhen Key Laboratory of Flexible Printed Electronics Technology, School of Science, Harbin Institute of Technology (Shenzhen), Shenzhen, 518055, China
| | - Zhenlin Chen
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Chun Ki Yiu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Qing'ao Qu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Zhiyuan Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Xinge Yu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
- City University of Hong Kong Shenzhen Research Institute, Shenzhen 518057, China
- Hong Kong Institute for Clean Energy, City University of Hong Kong, Kowloon, Hong Kong, China
| |
Collapse
|
2
|
Joung J, Jung CW, Lee HC, Chae MJ, Kim HS, Park J, Shin WY, Kim C, Lee M, Choi C. Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations. Sci Rep 2023; 13:8605. [PMID: 37244974 DOI: 10.1038/s41598-023-35492-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Accepted: 05/18/2023] [Indexed: 05/29/2023] Open
Abstract
Continuous, comfortable, convenient (C3), and accurate blood pressure (BP) measurement and monitoring are needed for early diagnosis of various cardiovascular diseases. To supplement the limited C3 BP measurement of existing cuff-based BP technologies, though they may achieve reliable accuracy, cuffless BP measurement technologies, such as pulse transit/arrival time, pulse wave analysis, and image processing, have been studied to obtain C3 BP measurement. One of the recent cuffless BP measurement technologies, innovative machine-learning and artificial intelligence-based technologies that can estimate BP by extracting BP-related features from photoplethysmography (PPG)-based waveforms have attracted interdisciplinary attention of the medical and computer scientists owing to their handiness and effectiveness for both C3 and accurate, i.e., C3A, BP measurement. However, C3A BP measurement remains still unattainable because the accuracy of the existing PPG-based BP methods was not sufficiently justified for subject-independent and highly varying BP, which is a typical case in practice. To circumvent this issue, a novel convolutional neural network(CNN)- and calibration-based model (PPG2BP-Net) was designed by using a comparative paired one-dimensional CNN structure to estimate highly varying intrasubject BP. To this end, approximately [Formula: see text], [Formula: see text], and [Formula: see text] of 4185 cleaned, independent subjects from 25,779 surgical cases were used for training, validating, and testing the proposed PPG2BP-Net, respectively and exclusively (i.e., subject-independent modelling). For quantifying the intrasubject BP variation from an initial calibration BP, a novel 'standard deviation of subject-calibration centring (SDS)' metric is proposed wherein high SDS represents high intrasubject BP variation from the calibration BP and vice versa. PPG2BP-Net achieved accurately estimated systolic and diastolic BP values despite high intrasubject variability. In 629-subject data acquired after 20 minutes following the A-line (arterial line) insertion, low error mean and standard deviation of [Formula: see text] and [Formula: see text] for highly varying A-line systolic and diastolic BP values, respectively, where their SDSs are 15.375 and 8.745. This study moves one step forward in developing the C3A cuffless BP estimation devices that enable the push and agile pull services.
Collapse
Affiliation(s)
- Jingon Joung
- Department of Electrical and Electronics Engineering, Chung-Ang University, Seoul, 06974, South Korea.
| | - Chul-Woo Jung
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, 03080, South Korea
| | - Hyung-Chul Lee
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, 03080, South Korea
| | - Moon-Jung Chae
- Department of Industrial Engineering, Seoul National University, Seoul, 08826, South Korea
| | - Hae-Sung Kim
- Department of Industrial Engineering, Seoul National University, Seoul, 08826, South Korea
| | - Jonghun Park
- Department of Industrial Engineering, Seoul National University, Seoul, 08826, South Korea
| | - Won-Yong Shin
- School of Mathematics and Computing (Computational Science and Engineering), Yonsei University, Seoul, 03722, South Korea
- Pohang University of Science and Technology (POSTECH) (Artificial Intelligence), Pohang, 37673, South Korea
| | | | | | | |
Collapse
|
3
|
Samimi H, Dajani HR. A PPG-Based Calibration-Free Cuffless Blood Pressure Estimation Method Using Cardiovascular Dynamics. SENSORS (BASEL, SWITZERLAND) 2023; 23:4145. [PMID: 37112490 PMCID: PMC10146008 DOI: 10.3390/s23084145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 04/18/2023] [Accepted: 04/19/2023] [Indexed: 06/19/2023]
Abstract
Traditional cuff-based sphygmomanometers for measuring blood pressure can be uncomfortable and particularly unsuitable to use during sleep. A proposed alternative method uses dynamic changes in the pulse waveform over short intervals and replaces calibration with information from photoplethysmogram (PPG) morphology to provide a calibration-free approach using a single sensor. Results from 30 patients show a high correlation of 73.64% for systolic blood pressure (SBP) and 77.72% for diastolic blood pressure (DBP) between blood pressure estimated with the PPG morphology features and the calibration method. This suggests that the PPG morphology features could replace the calibration stage for a calibration-free method with similar accuracy. Applying the proposed methodology on 200 patients and testing on 25 new patients resulted in a mean error (ME) of -0.31 mmHg, a standard deviation of error (SDE) of 4.89 mmHg, a mean absolute error (MAE) of 3.32 mmHg for DBP and an ME of -4.02 mmHg, an SDE of 10.40 mmHg, and an MAE of 7.41 mmHg for SBP. These results support the potential for using a PPG signal for calibration-free cuffless blood pressure estimation and improving accuracy by adding information from cardiovascular dynamics to different methods in the cuffless blood pressure monitoring field.
Collapse
|
4
|
Rafieivand S, Hassan Moradi M, Momayez Sanat Z, Asl Soleimani H. A fuzzy-based framework for diagnosing esophageal motility disorder using high-resolution manometry. J Biomed Inform 2023; 141:104355. [PMID: 37023842 DOI: 10.1016/j.jbi.2023.104355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Revised: 03/05/2023] [Accepted: 03/30/2023] [Indexed: 04/08/2023]
Abstract
In recent years, the high-resolution manometry (HRM) technique has been increasingly used to study esophageal and colonic pressurization and has become a standard routine for discovering mobility disorders. In addition to evolving guidelines for the interpretation of HRM like Chicago standard, some complexities, such as the dependency of normative reference values on the recording device and other external variables, still remain for medical professions. In this study, a decision support framework is developed to aid the diagnosis of esophageal mobility disorders based on HRM data. To abstract HRM data, Spearman correlation is employed to model the spatio-temporal dependencies of pressure values of HRM components and convolutional graph neural networks are then utilized to embed relation graphs to the features vector. In the decision-making stage, a novel Expert per Class Fuzzy Classifier (EPC-FC) is presented that employs the ensemble structure and contains expertized sub-classifiers for recognizing a specific disorder. Training sub-classifiers using the negative correlation learning method makes the EPC-FC highly generalizable. Meanwhile, separating the sub-classifiers of each class gives flexibility and interpretability to the structure. The suggested framework is evaluated on a dataset of 67 patients in 5 different classes recorded in Shariati Hospital. The average accuracy of 78.03% for a single swallow and 92.54% for subject-level is achieved for distinguishing mobility disorders. Moreover, compared with the other studies, the presented framework has an outstanding performance considering that it imposes no limits on the type of classes or HRM data. On the other hand, the EPC-FC outperforms other comparative classifiers such as SVM and AdaBoost not only in HRM diagnosis but also on other benchmark classification problems.
Collapse
Affiliation(s)
- Safa Rafieivand
- Department of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
| | | | - Zahra Momayez Sanat
- Digestive Disease Research Institute, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Hosein Asl Soleimani
- Digestive Disease Research Institute, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
5
|
Fuadah YN, Lim KM. Classification of Blood Pressure Levels Based on Photoplethysmogram and Electrocardiogram Signals with a Concatenated Convolutional Neural Network. Diagnostics (Basel) 2022; 12:diagnostics12112886. [PMID: 36428946 PMCID: PMC9689744 DOI: 10.3390/diagnostics12112886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 11/04/2022] [Accepted: 11/16/2022] [Indexed: 11/23/2022] Open
Abstract
Hypertension is a severe public health issue worldwide that significantly increases the risk of cardiac vascular disease, stroke, brain hemorrhage, and renal dysfunction. Early screening of blood pressure (BP) levels is essential to prevent the dangerous complication associated with hypertension as the leading cause of death. Recent studies have focused on employing photoplethysmograms (PPG) with machine learning to classify BP levels. However, several studies claimed that electrocardiograms (ECG) also strongly correlate with blood pressure. Therefore, we proposed a concatenated convolutional neural network which integrated the features extracted from PPG and ECG signals. This study used the MIMIC III dataset, which provided PPG, ECG, and arterial blood pressure (ABP) signals. A total of 14,298 signal segments were obtained from 221 patients, which were divided into 9150 signals of train data, 2288 signals of validation data, and 2860 signals of test data. In the training process, five-fold cross-validation was applied to select the best model with the highest classification performance. The proposed concatenated CNN architecture using PPG and ECG obtained the highest test accuracy of 94.56-95.15% with a 95% confidence interval in classifying BP levels into hypotension, normotension, prehypertension, hypertension stage 1, and hypertension stage 2. The result shows that the proposed method is a promising solution to categorize BP levels effectively, assisting medical personnel in making a clinical diagnosis.
Collapse
Affiliation(s)
- Yunendah Nur Fuadah
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
- School of Electrical Engineering, Telkom University, Bandung 40257, Indonesia
| | - Ki Moo Lim
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
- Computational Medicine Lab, Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
- Correspondence:
| |
Collapse
|
6
|
Khodabakhshi MB, Eslamyeh N, Sadredini SZ, Ghamari M. Cuffless blood pressure estimation using chaotic features of photoplethysmograms and parallel convolutional neural network. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 226:107131. [PMID: 36137326 DOI: 10.1016/j.cmpb.2022.107131] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 08/26/2022] [Accepted: 09/13/2022] [Indexed: 06/16/2023]
Abstract
BACKGROUND AND OBJECTIVE As a nonlinear framework in dynamical system analysis, chaotic approaches are mainly applied to evolve the complexity of biological systems. Due to the chaotic nature of the cardiovascular systems, the nonlinear features can intuitively provide a reliable framework in blood pressure (BP) estimation. Cuffless BP estimation is usually carried out by establishing deep neural network models estimating the BP values through machine-learned features of photoplethysmogram (PPG) signals. METHODS In this study, a novel parallel deep architecture is proposed to handle the machine-learned and chaotic features of PPG signals in estimating the actual BP values. The chaotic handcrafted features were the signal properties associated with the Poincare sections in the phase space and the recurrence plot-based measures called recurrence quantification analysis (RQA). Moreover, the measures quantifying the nonlinear properties of the temporal sequences such as correlation dimension, fractal dimension, Lyapunov exponent, and entropy-based quantities were also employed. The parallel architecture not only embedded the chaotic nature of PPG signals but also provided a facility to include the pseudo-periodic variations of PPGs by utilizing a concatenating layer. RESULTS Our framework was examined on the public dataset, namely, Multi-Parameter Intelligent in Intensive Care II contained the recording of PPG, ECG and arterial blood pressure. The performance of the employed handcrafted features in distinguishing between the levels of BP values was investigated based on Spearman's statistics. In addition, our proposed scheme is evaluated in terms of Pearson's correlation coefficient (R), root mean square error (RMSE), and mean absolute error (MAE). The best performance was achieved when the employed handcrafted features accompanied by PPG sequences were applied to the parallel deep network. In particular, the values of R, RMSE, and MAE were obtained 0.9529, 2.76 mmHg, and 1.73 mmHg for diastolic BP, and 0.9444, 6.18 mmHg, and 3.8 mmHg for systolic BP, respectively. Moreover, based on the requirements of the standards set by the British Hypertension Society (BHS), the proposed scheme achieved a grade of A. CONCLUSIONS Our proposed scheme outperformed the state-of-the-art BP estimation methods. In addition, the results confirmed that the concatenation of the PPG-related machine-learned and nonlinear handcrafted features can be properly applied in continuous BP monitoring.
Collapse
Affiliation(s)
- Mohammad Bagher Khodabakhshi
- Department of Biomedical Engineering, Hamedan University of Technology, Mardom St, Shahid Fahmideh Blvd, Hamedan 6516913733, Iran.
| | - Naeem Eslamyeh
- Department of Biomedical Engineering, Hamedan University of Technology, Mardom St, Shahid Fahmideh Blvd, Hamedan 6516913733, Iran
| | - Seyede Zohreh Sadredini
- Department of Biomedical Engineering, Hamedan University of Technology, Mardom St, Shahid Fahmideh Blvd, Hamedan 6516913733, Iran
| | - Mohammad Ghamari
- Department of Computer Engineering, Hamedan University of Technology, Hamedan 6516913733, Iran
| |
Collapse
|