1
|
Zhou S, Weng L, Zhou C, Zhou J, Min SH. Reduced Monocular Luminance Promotes Fusion But Not Mixed Perception in Amblyopia. Invest Ophthalmol Vis Sci 2024; 65:15. [PMID: 38587443 PMCID: PMC11008760 DOI: 10.1167/iovs.65.4.15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Accepted: 03/11/2024] [Indexed: 04/09/2024] Open
Abstract
Purpose The purpose of this study was to understand how monocular luminance reduction affects binocular balance and examine whether it differentially influences fusion and mixed perception in amblyopia. Methods Twenty-three normally sighted observers and 12 adults with amblyopia participated in this study. A novel binocular rivalry task was used to measure the phase duration of four perceptual responses (right- and left-tilts, fusion, and mixed perception) before and after a neutral density (ND) filter was applied at various levels to the dominant eye (DE) of controls and the fellow eye (FE) of patients with amblyopia. Phase durations were analyzed to assess whether the duration of fusion or mixed perception shifted after monocular luminance reduction. Moreover, we quantified ocular dominance and adjusted monocular contrast and luminance separately to investigate the relationship between changes in ocular dominance induced by the two manipulations. Results In line with previous studies, binocular balance shifted in favor of the brighter eye in both normal adults and patients with amblyopia. As a function of the ND filter's density, the duration of fusion and mixed perception decreased in normal controls, whereas that of fusion but not mixed perception increased significantly in patients with amblyopia. In addition, changes in binocular balance from luminance reduction were more significant in more balanced amblyopes or normal observers. Furthermore, shifts in binocular balance after contrast and luminance modulation were correlated in both normal and amblyopic observers. Conclusions The duration of fusion but not mixed perception increased in amblyopia after monocular luminance reduction in the FE. Moreover, our findings demonstrate that changes in ocular dominance from contrast-modulation and luminance-modulation are correlated in both normal and amblyopic observers.
Collapse
Affiliation(s)
- Shiqi Zhou
- School of Ophthalmology and Optometry and Eye Hospital, and State Key Laboratory of Ophthalmology, Optometry and Vision Science, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Liuqing Weng
- School of Ophthalmology and Optometry and Eye Hospital, and State Key Laboratory of Ophthalmology, Optometry and Vision Science, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Chenyan Zhou
- School of Ophthalmology and Optometry and Eye Hospital, and State Key Laboratory of Ophthalmology, Optometry and Vision Science, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Jiawei Zhou
- School of Ophthalmology and Optometry and Eye Hospital, and State Key Laboratory of Ophthalmology, Optometry and Vision Science, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Seung Hyun Min
- School of Ophthalmology and Optometry and Eye Hospital, and State Key Laboratory of Ophthalmology, Optometry and Vision Science, Wenzhou Medical University, Wenzhou, Zhejiang, China
| |
Collapse
|
2
|
Castet E, Termoz-Masson J, Vizcay S, Delachambre J, Myrodia V, Aguilar C, Matonti F, Kornprobst P. PTVR - A software in Python to make virtual reality experiments easier to build and more reproducible. J Vis 2024; 24:19. [PMID: 38652657 PMCID: PMC11044846 DOI: 10.1167/jov.24.4.19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Accepted: 02/25/2024] [Indexed: 04/25/2024] Open
Abstract
Researchers increasingly use virtual reality (VR) to perform behavioral experiments, especially in vision science. These experiments are usually programmed directly in so-called game engines that are extremely powerful. However, this process is tricky and time-consuming as it requires solid knowledge of game engines. Consequently, the anticipated prohibitive effort discourages many researchers who want to engage in VR. This paper introduces the Perception Toolbox for Virtual Reality (PTVR) library, allowing visual perception studies in VR to be created using high-level Python script programming. A crucial consequence of using a script is that an experiment can be described by a single, easy-to-read piece of code, thus improving VR studies' transparency, reproducibility, and reusability. We built our library upon a seminal open-source library released in 2018 that we have considerably developed since then. This paper aims to provide a comprehensive overview of the PTVR software for the first time. We introduce the main objects and features of PTVR and some general concepts related to the three-dimensional (3D) world. This new library should dramatically reduce the difficulty of programming experiments in VR and elicit a whole new set of visual perception studies with high ecological validity.
Collapse
Affiliation(s)
- Eric Castet
- Aix Marseille Univ, CNRS, CRPN, Marseille, France
| | | | | | | | | | | | | | | |
Collapse
|
3
|
Domsa P, Bankó ÉM, Körtvélyes J, Meigen C, Széchey R, Lantos K, Nagy ZZ, Csutak A. Astigmatism and maternal myopia as important factors affecting success rate of DIMS lens treatment. BMJ Open Ophthalmol 2024; 9:e001499. [PMID: 38453262 PMCID: PMC10921505 DOI: 10.1136/bmjophth-2023-001499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 01/28/2024] [Indexed: 03/09/2024] Open
Abstract
OBJECTIVE To assess the efficacy of myopia control spectacle lenses (defocus incorporated multiple segments/DIMS) in slowing myopia progression among a diverse Central European paediatric population and investigate the contribution of baseline parameters on treatment outcomes. METHODS AND ANALYSIS This retrospective observational study included 62 individuals aged 4-17 years (mean±SD: 10.21±2.70) with progressing myopia but without ocular pathology with a range of -0.88 to -8.25 D spherical equivalent refraction (SER) (-3.73±1.56), coupled with astigmatism up to -3.25 D cylindrical. All participants were prescribed DIMS (Hoya MiyoSmart) spectacles. Key outcome variables were cycloplegic SER, measured for all participants and axial length (AL), assessed in a subset of patients, recorded at baseline, 6 months and 12 months. Quality of life assessments were conducted at baseline, at 2 weeks, and 3, 6, 9 and 12 months. Additionally, parental myopic dioptre was recorded when applicable. RESULTS At the 12-month mark, myopia progression in patients (mean±SE: -0.40±0.05) mirrored findings from prior European DIMS studies, but with 50% of patients showing no progression. A multivariate analysis of covariance model revealed that baseline astigmatism and younger age adversely affected therapy outcomes in both SER and AL, while severe maternal myopia led to greater SER progression. In contrast, only young age but not astigmatism was associated with AL increase in a comparable group of children with myopia, part of the LIFE Child Study, wearing single-vision spectacles. Patients reported consistent satisfaction with treatment, with minimal side effects, which diminished over the year. CONCLUSION In the European population, astigmatism, young age and severe maternal myopia are risk factors for suboptimal outcomes following DIMS therapy. Further research is necessary to elucidate the impact of astigmatism on myopic defocus therapy.
Collapse
Affiliation(s)
- Patricia Domsa
- Non Plus Ultra Vision Centre, Budapest, Hungary
- Department of Ophthalmology, University of Pécs Medical School, Pecs, Hungary
| | - Éva M Bankó
- HUN-REN Research Centre for Natural Sciences, Budapest, Hungary
| | - Judit Körtvélyes
- Non Plus Ultra Vision Centre, Budapest, Hungary
- Heim Pál National Pediatric Institute, Budapest, Hungary
| | - Christof Meigen
- LIFE Leipzig Research Center for Civilization Diseases, Leipzig University, Leipzig, Germany
| | - Rita Széchey
- Non Plus Ultra Vision Centre, Budapest, Hungary
- Semmelweis University of Medicine, Budapest, Hungary
| | - Krisztina Lantos
- Department of Ophthalmology, University of Pécs Medical School, Pecs, Hungary
| | - Zoltán Zsolt Nagy
- Department of Ophthalmology, Semmelweis University of Medicine, Budapest, Hungary
| | - Adrienne Csutak
- Department of Ophthalmology, University of Pécs Medical School, Pecs, Hungary
| |
Collapse
|
4
|
Tsaousis KT, Mousteris G, Diakonis V, Chaloulis S. Current Developments in the Management of Amblyopia with the Use of Perceptual Learning Techniques. MEDICINA (KAUNAS, LITHUANIA) 2023; 60:48. [PMID: 38256309 PMCID: PMC10821148 DOI: 10.3390/medicina60010048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 12/22/2023] [Accepted: 12/25/2023] [Indexed: 01/24/2024]
Abstract
Background and Objectives: Amblyopia is a neurodevelopmental disorder caused by interocular suppression of visual input, affecting visual acuity, stereopsis, contrast sensitivity, and other visual functions. Conventional treatment comprises occlusion of the sound eye. In recent years, novel therapies that deploy perceptual learning (PL) principles have been introduced. The purpose of this study is to assess the latest scientific data on this topic. Materials and Methods: For this purpose, we conducted a literature search for relevant studies published during the previous 4 years (2020-2023). Results: A plethora of visual perceptual learning protocols have been recently developed. Dichoptic video games, contrast rebalanced movies, and online perceptual training platforms are the main formats. Perceptual learning activates neuroplasticity, overcomes interocular suppression, and improves the visual impairments induced by amblyopia. Conclusions: This novel treatment is effective in both children and adults, as well as in patients non-responding to patching.
Collapse
Affiliation(s)
| | | | - Vasilios Diakonis
- 2nd Ophthalmology Department, Metropolitan Hospital, 185 47 Athens, Greece
| | | |
Collapse
|
5
|
Rao T, Zou W, Hu X, He H, Luo W, You Z. Evaluation of retinal microcirculation alterations using OCTA in hyperopic ametropic amblyopia patients before and after treatment. Int Ophthalmol 2023; 43:3075-3085. [PMID: 37081133 PMCID: PMC10400672 DOI: 10.1007/s10792-023-02707-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 04/09/2023] [Indexed: 04/22/2023]
Abstract
PURPOSE We aimed to compare retinal microcirculation in hyperopic ametropic amblyopia patients before and after treatment and in healthy children using optical coherence tomography angiography (OCTA), and to explore the pathogenesis of hyperopic ametropic amblyopia. METHODS Eighteen patients with hyperopic ametropic amblyopia aged 4-8 years were selected as the patient group, and 18 age-matched healthy children were randomly selected as controls. The foveal avascular zone (FAZ) area, perimeter and circularity, vessel density (VD) and perfusion density (PD) of macular superficial retinal capillary plexus, macular thickness, peripapillary retinal nerve fiber layer thickness, and ganglion cell-inner plexiform layer thickness were compared between both groups. After 6 months of amblyopia treatment, the same parameters were measured again. RESULTS The VD and PD in the central, inner, inner nasal, and inner inferior regions in hyperopic ametropic amblyopia were lower than in the control group after adjustment for axial length. After 6 months of treatment, the VD increased significantly, except in the outer nasal and outer inferior regions. The PD in the central (p < 0.001), inner superior (p = 0.001), inner inferior (p = 0.011) and inner temporal (p = 0.026) regions increased. The FAZ perimeter and circularity significantly differed between the groups. After 6 months of treatment, the FAZ area and perimeter decreased, but circularity increased. CONCLUSION Hyperopic ametropic amblyopia eyes showed a significant decrease in vessel and perfusion densities. After amblyopia treatment, the vessel and perfusion densities of patients with hyperopic ametropic amblyopia increased, suggesting that abnormalities in the microvascular system are a pathogenic factor of amblyopia.
Collapse
Affiliation(s)
- Ting Rao
- Affiliated Eye Hospital of Nanchang University, Nanchang, China
| | - Wen Zou
- Nanchang Hongdu Hospital of Traditional Chinese Medicine, Nanchang, China
| | - Xiaoqin Hu
- Affiliated Eye Hospital of Nanchang University, Nanchang, China
| | - Hai He
- Affiliated Eye Hospital of Nanchang University, Nanchang, China
| | - Wei Luo
- Affiliated Eye Hospital of Nanchang University, Nanchang, China
| | - Zhipeng You
- Affiliated Eye Hospital of Nanchang University, Nanchang, China.
| |
Collapse
|
6
|
Levi DM. Applications and implications for extended reality to improve binocular vision and stereopsis. J Vis 2023; 23:14. [PMID: 36662501 PMCID: PMC9872838 DOI: 10.1167/jov.23.1.14] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Accepted: 12/12/2022] [Indexed: 01/21/2023] Open
Abstract
Extended reality (XR) devices, including virtual reality (VR), augmented reality (AR), and mixed reality (MR) devices, are immersive technologies that can swap or merge the natural environment with virtual content (e.g., videogames, movies, or other content). Although these devices are widely used for playing videogames and other applications, they have one distinct feature that makes them potentially very useful for the measurement and treatment of binocular vision anomalies-they can deliver different content to the two eyes simultaneously. Indeed, horizontally shifting the images in the two eyes (thereby creating binocular disparity) can provide the user with a compelling percept of depth through stereopsis. Because these devices are stereoscopic, they can also be used as high-tech synoptophores, in which the images to the two eyes differ in contrast, luminance, size, position, and content for measuring and treating binocular anomalies. The inclusion of eye tracking in VR adds an additional dimension to its utility in measuring and treating binocular vision anomalies, as well as other conditions. This paper describes the essential requirements for testing and treating binocular anomalies and reviews current studies in which XR devices have been used to measure and treat binocular vision anomalies.
Collapse
Affiliation(s)
- Dennis M Levi
- Herbert Wertheim School of Optometry and Vision Science, University of California, Berkeley, Berkeley, CA, USA
| |
Collapse
|