1
|
Thiruchelvam N, Landauro MH, Biardeau X, Rovsing C, Hahn M, Nascimento OFD, Gardner S, Amarenco G, Bagi P. Improved emptying performance with a new micro-hole zone catheter in adult male intermittent catheter users: A comparative multi-center randomized controlled cross-over study. Neurourol Urodyn 2024; 43:464-478. [PMID: 38196237 DOI: 10.1002/nau.25383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 12/12/2023] [Accepted: 12/17/2023] [Indexed: 01/11/2024]
Abstract
AIMS To confirm the improved performance of the micro-hole zone catheter (MHZC) compared to a conventional eyelet catheter (CEC) in male users of clean intermittent catheterizations (CICs). METHODS Male self-catheterizing subjects, who used hydrophilic sleeved soft/flexible CIC as the only bladder emptying method, were enrolled into a multi-center, randomized, cross-over study performed across six European sites. Subjects tested the MHZC, featuring a drainage zone with 120 micro-holes and a CEC with two eyelets. The study consisted of four study visits (V0-V3), during which endpoints related to catheter performance (urinary flow-stops, bladder emptying, and intra-catheter pressure) were measured and two 4-week test periods at home (T1 and T2) where dipstick hematuria and user perception between catheters were evaluated. RESULTS Seventy-three male subjects with non-neurogenic and neurogenic bladder dysfunction (3:2) were enrolled. On average, catheterizations with the MHZC led to close to mean zero flow-stops compared to ≥1 flow-stops with the CEC, during both HCP- and self-led catheterizations (both p < 0.001). Residual urine at first flow-stop was significantly reduced for the MHZC compared to CEC (p = 0.001 and p = 0.004, for HCP- and self-led catheterizations, respectively). This was substantiated by a significantly smaller pressure peak at first flow-stop, a proxy for minimized mucosal suction (both HCP- and self-led catheterizations, p < 0.001). After home-use catheterizations, dipstick hematuria was comparable between catheters, whereas catheterizations were associated with significantly improved perception in favor of MHZC regarding bladder emptying, less blocking sensation, and improved hygienic catheterization compared to the CEC. CONCLUSION This study confirmed the evidence of improved bladder emptying with the MHZC compared to a CEC without the need to reposition the catheter. The MHZC therefore offers an enhanced benefit for the dependent CIC user securing complete bladder emptying in an uninterrupted free flow and reducing the need to reposition the catheter during emptying.
Collapse
Affiliation(s)
- Nikesh Thiruchelvam
- Department of Urology, NHS Foundation Trust, Addenbrooke's Hospital, Cambridge University Hospital, Cambridge, UK
| | | | - Xavier Biardeau
- Centre Hospitalier Universitaire de Lille, Lille Cedex, France
| | | | - Markus Hahn
- ARTIMED Medical Consulting GmbH, Kassel, Germany
| | | | | | | | - Per Bagi
- Department of Urology, Rigshospitalet, København Ø, Denmark
| |
Collapse
|
2
|
Landauro MH, Tentor F, Pedersen T, Jacobsen L, Bagi P. Improved Performance With the Micro-Hole Zone Intermittent Catheter: A Combined Analysis of 3 Randomized Controlled Studies Comparing the New Catheter Technology With a Conventional Eyelet Catheter. J Wound Ostomy Continence Nurs 2023; 50:504-511. [PMID: 37966080 PMCID: PMC10681284 DOI: 10.1097/won.0000000000001029] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2023]
Abstract
PURPOSE To assess the performance of a new urinary intermittent catheter (IC) prototype designed with a micro-hole drainage zone compared to a conventional eyelet catheter (CEC) in terms of flow-stop, bladder emptying, and hematuria. DESIGN Randomized controlled crossover studies. SUBJECT AND SETTING The sample comprised 15 male healthy volunteers (HV) and 15 IC users, along with 15 female HV and 15 IC users. The age range was lower for HV participants than for IC users (range: 20-57 years for HV vs 21-82 years for IC users). The study setting was the Department of Urology, located in Rigshospitalet, Copenhagen. METHODS Number of flow-stop incidents, residual urine volume at first flow-stop (RV1), and dipstick hematuria were measured during and after catheterization by a health care professional (HV) and by self-catheterisation (IC-users). Results from the 3 studies were combined for HV and IC users on RV1 and number of flow-stop incidents but separated on sex. For incidents of hematuria, an effect of underlying condition was assumed, and a combined analysis on sex was performed, separating HV and IC users. RESULTS When compared to the micro-hole drainage zone design, catheterizations with CEC resulted in a significantly higher mean RV1 (mean difference: 49 mL in males and 32 mL in females, both P < .001) and average number of flow-stop incidents (8 and 21 times more frequent for males and females, respectively, both P < .001). The likelihood for hematuria was 5.84 higher with CEC than with micro-hole drainage hole design, P = .053, during normal micturition in HV postcatheterization. No serious adverse events were reported. CONCLUSION The micro-hole drainage zone catheter provides IC users fewer premature flow-stops. This design feature reduces modifiable urinary tract infection risk factors, such as residual urine and micro-trauma; additional research is needed to determine its effects on bladder health.
Collapse
Affiliation(s)
- Malene Hornbak Landauro
- Correspondence: Malene Hornbak Landauro, PhD, Coloplast A/S, Holtedam 3, 3050 Humlebaek, Denmark ()
| | - Fabio Tentor
- Malene Hornbak Landauro, PhD, Coloplast A/S, Humlebæk, Denmark
- Fabio Tentor, PhD, Coloplast A/S, Humlebæk, Denmark
- Troels Pedersen, MS, Coloplast A/S, Humlebæk, Denmark
- Lotte Jacobsen, MS, Coloplast A/S, Humlebæk, Denmark
- Per Bagi, MD, Department of Urology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| | - Troels Pedersen
- Malene Hornbak Landauro, PhD, Coloplast A/S, Humlebæk, Denmark
- Fabio Tentor, PhD, Coloplast A/S, Humlebæk, Denmark
- Troels Pedersen, MS, Coloplast A/S, Humlebæk, Denmark
- Lotte Jacobsen, MS, Coloplast A/S, Humlebæk, Denmark
- Per Bagi, MD, Department of Urology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| | - Lotte Jacobsen
- Malene Hornbak Landauro, PhD, Coloplast A/S, Humlebæk, Denmark
- Fabio Tentor, PhD, Coloplast A/S, Humlebæk, Denmark
- Troels Pedersen, MS, Coloplast A/S, Humlebæk, Denmark
- Lotte Jacobsen, MS, Coloplast A/S, Humlebæk, Denmark
- Per Bagi, MD, Department of Urology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| | - Per Bagi
- Malene Hornbak Landauro, PhD, Coloplast A/S, Humlebæk, Denmark
- Fabio Tentor, PhD, Coloplast A/S, Humlebæk, Denmark
- Troels Pedersen, MS, Coloplast A/S, Humlebæk, Denmark
- Lotte Jacobsen, MS, Coloplast A/S, Humlebæk, Denmark
- Per Bagi, MD, Department of Urology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
3
|
Le Garrec D, Chesnel C, Teng M, Lagnau P, Brouchet M, Chea M, Amarenco G, Hentzen C. [Intermittent catheterization: What are the environmental impacts and how can they be reduced?]. Prog Urol 2023; 33:533-540. [PMID: 37596127 DOI: 10.1016/j.purol.2023.07.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2023] [Revised: 07/09/2023] [Accepted: 07/10/2023] [Indexed: 08/20/2023]
Abstract
INTRODUCTION If the use of intermittent catheterization has revolutionized the prognosis of neuro-urology patients, it seems necessary to question the ecological cost of single-use catheters, in a process of decarbonization of the health sector. The aim of this work is to identify the environmental impact of intermittent catheterization and potential solutions to reduce it. METHODS A review of the literature on the environmental impact of intermittent catheterizations was conducted. Potential solutions to reduce this impact and possible alternatives were then studied based on data from the literature. RESULTS Only two studies were identified. The first estimated the amount of waste generated by intermittent catheterization in the USA to be between 4400 and 38,964 tons per year. The second study showed a higher overall environmental impact of thermoplastic polyurethane (TPU) catheters than polyvinyl chloride (PVC) catheters and catheters made from polyolefin material. Reuse of catheters would reduce the amount of waste, but the paucity of data does not allow us to determine if the incidence of urinary tract infection would be affected. Alternative micturition methods, in addition to the complications they may cause, require the use of collection bags or pads, which also have an environmental impact. Other treatments for dysuria exist, but the evidence is limited and does not cover all patient populations. CONCLUSION With limited alternatives, it appears essential to develop more environmentally friendly catheters.
Collapse
Affiliation(s)
- D Le Garrec
- GRC 01, GREEN Groupe de recherche clinique en neuro-urologie, AP-HP, hôpital Tenon, Sorbonne Université, 75020 Paris, France.
| | - C Chesnel
- GRC 01, GREEN Groupe de recherche clinique en neuro-urologie, AP-HP, hôpital Tenon, Sorbonne Université, 75020 Paris, France
| | - M Teng
- GRC 01, GREEN Groupe de recherche clinique en neuro-urologie, AP-HP, hôpital Tenon, Sorbonne Université, 75020 Paris, France
| | - P Lagnau
- GRC 01, GREEN Groupe de recherche clinique en neuro-urologie, AP-HP, hôpital Tenon, Sorbonne Université, 75020 Paris, France
| | - M Brouchet
- GRC 01, GREEN Groupe de recherche clinique en neuro-urologie, AP-HP, hôpital Tenon, Sorbonne Université, 75020 Paris, France
| | - M Chea
- GRC 01, GREEN Groupe de recherche clinique en neuro-urologie, AP-HP, hôpital Tenon, Sorbonne Université, 75020 Paris, France
| | - G Amarenco
- GRC 01, GREEN Groupe de recherche clinique en neuro-urologie, AP-HP, hôpital Tenon, Sorbonne Université, 75020 Paris, France
| | - C Hentzen
- GRC 01, GREEN Groupe de recherche clinique en neuro-urologie, AP-HP, hôpital Tenon, Sorbonne Université, 75020 Paris, France
| |
Collapse
|
4
|
Zachariou A, Zachariou D, Kaltsas A, Giannakis I, Dimitriadis F, Douvli E, Champilomatis I, Kounavou C, Papatsoris A, Tsounapi P, Mamoulakis C, Takenaka A, Sofikitis N. Translation and Validation of the Intermittent Catheterization Difficulty Questionnaire (ICDQ) into Greek. J Multidiscip Healthc 2022; 15:2571-2577. [PMID: 36388624 PMCID: PMC9656416 DOI: 10.2147/jmdh.s387110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 10/31/2022] [Indexed: 11/11/2022] Open
Abstract
Purpose Clean intermittent self-catheterization (CISC) is a safe and effective alternative to managing incomplete bladder emptying in patients afflicted with neurogenic bladder conditions. The Intermittent Catheterisation Difficulty Questionnaire (ICDQ) is a validated questionnaire concerning the assessment of catheter use and patient difficulties during CISC. The present study aimed to translate and validate the ICDQ into the Greek language. A subsequent outcome was to substantiate the requirement of both urologist consultation with patients undergoing CISC and the detailed evaluation of various therapeutic options with the consultation of other specialist physicians. Material and Methods The study was undertaken between March 2022 and July 2022 and involved patients in an outpatient department of a Rehabilitation Centre. Sixty-two neurologic patients suffering from spinal cord injury (SCI), multiple sclerosis (MS), cauda equina (CE), and myelitis represented a convenience sample. To calculate test-retest reliability, patients filled out two consecutive questionnaires; an initial one and a second after one week. The socio and demographic circumstances of all participants were evaluated. Results The mean ICDQ total score at the test and retest was 5.96±1.28 (mean total score ± standard deviation) and 5.91±1.29, respectively. Evaluation of the data concerning alterations between men and women did not reveal statistically significant differences. Cronbach’s alpha coefficient was 0.94, which proves the inter-correlation between the different topics. An ICC of 0.97 indicated very high intra-rater reliability. Conclusion ICDQ, a valid and reliable self-administered screening tool for CISC difficulties faced by patients using this procedure regularly, was successfully translated and validated into Greek. A more detailed evaluation and understanding of these difficulties would enhance the quality of CISC and allow for more suitable treatment and the selection of catheter types used. These improved treatment strategies are possible as repeated use and constant comparison of ICDQ scores determine treatment impact, facilitating treatment regimen modification, should it be required.
Collapse
Affiliation(s)
- Athanasios Zachariou
- Department of Urology, University of Ioannina, Ioannina, Greece
- Physical Medicine and Rehabilitation Centre EU PRATTEIN, Volos, Greece
- Correspondence: Athanasios Zachariou, Urology Department, Ioannina University, Volos, 38221, Greece, Tel +302421026937, Email
| | - Dimitrios Zachariou
- Department of Urology, University of Ioannina, Ioannina, Greece
- Physical Medicine and Rehabilitation Centre EU PRATTEIN, Volos, Greece
| | - Aris Kaltsas
- Department of Urology, University of Ioannina, Ioannina, Greece
| | | | - Fotios Dimitriadis
- Department of Urology, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Erriketi Douvli
- Department of Urology, University of Ioannina, Ioannina, Greece
| | | | | | - Athanasios Papatsoris
- 2nd Department of Urology, Sismanogleion General Hospital, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece
| | - Panagiota Tsounapi
- Department of Urology, Faculty of Medicine, Tottori University, Yonago, Japan
| | | | - Atsushi Takenaka
- Department of Urology, Faculty of Medicine, Tottori University, Yonago, Japan
| | | |
Collapse
|
5
|
Farrelly E, Peeker R. 50 Years with clean intermittent self-catheterization - a Scandinavian perspective. Scand J Urol 2022; 56:166-167. [PMID: 35244519 DOI: 10.1080/21681805.2022.2046151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 02/18/2022] [Accepted: 02/19/2022] [Indexed: 10/18/2022]
Affiliation(s)
| | - Ralph Peeker
- Department of Urology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
6
|
Prieto JA, Murphy CL, Stewart F, Fader M. Intermittent catheter techniques, strategies and designs for managing long-term bladder conditions. Cochrane Database Syst Rev 2021; 10:CD006008. [PMID: 34699062 PMCID: PMC8547544 DOI: 10.1002/14651858.cd006008.pub5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Intermittent catheterisation (IC) is a commonly recommended procedure for people with incomplete bladder emptying. Frequent complications are urinary tract infection (UTI), urethral trauma and discomfort during catheter use. Despite the many designs of intermittent catheter, including different lengths, materials and coatings, it is unclear which catheter techniques, strategies or designs affect the incidence of UTI and other complications, measures of satisfaction/quality of life and cost-effectiveness. This is an update of a Cochrane Review first published in 2007. OBJECTIVES: To assess the clinical and cost-effectiveness of different catheterisation techniques, strategies and catheter designs, and their impact, on UTI and other complications, and measures of satisfaction/quality of life among adults and children whose long-term bladder condition is managed by intermittent catheterisation. SEARCH METHODS We searched the Cochrane Incontinence Specialised Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, MEDLINE In-Process, MEDLINE Epub Ahead of Print, CINAHL, ClinicalTrials.gov, WHO ICTRP and handsearching of journals and conference proceedings (searched 12 April 2021), the reference lists of relevant articles and conference proceedings, and we attempted to contact other investigators for unpublished data or for clarification. SELECTION CRITERIA Randomised controlled trials (RCTs) or randomised cross-over trials comparing at least two different catheterisation techniques, strategies or catheter designs. DATA COLLECTION AND ANALYSIS As per standard Cochrane methodological procedures, two review authors independently extracted data, assessed risk of bias and assessed the certainty of evidence using GRADE. Outcomes included the number of people with symptomatic urinary tract infections, complications such as urethral trauma/bleeding, comfort and ease of use of catheters, participant satisfaction and preference, quality of life measures and economic outcomes. MAIN RESULTS We included 23 trials (1339 randomised participants), including twelve RCTs and eleven cross-over trials. Most were small (fewer than 60 participants completed), although three trials had more than 100 participants. Length of follow-up ranged from one month to 12 months and there was considerable variation in definitions of UTI. Most of the data from cross-over trials were not presented in a useable form for this review. Risk of bias was unclear in many domains due to insufficient information in the trial reports and several trials were judged to have a high risk of performance bias due to lack of blinding and a high risk of attrition bias. The certainty of evidence was downgraded for risk of bias, and imprecision due to low numbers of participants. Aseptic versus clean technique We are uncertain if there is any difference between aseptic and clean techniques in the risk of symptomatic UTI because the evidence is low-certainty and the 95% confidence interval (CI) is consistent with possible benefit and possible harm (RR 1.20 95% CI 0.54 to 2.66; one study; 36 participants). We identified no data relating to the risk of adverse events comparing aseptic and clean techniques or participant satisfaction or preference. Single-use (sterile) catheter versus multiple-use (clean) We are uncertain if there is any difference between single-use and multiple-use catheters in terms of the risk of symptomatic UTI because the certainty of evidence is low and the 95% CI is consistent with possible benefit and possible harm (RR 0.98, 95% CI 0.55, 1.74; two studies; 97 participants). One study comparing single-use catheters to multiple-use catheters reported zero adverse events in either group; no other adverse event data were reported for this comparison. We identified no data for participant satisfaction or preference. Hydrophilic-coated catheters versus uncoated catheters We are uncertain if there is any difference between hydrophilic and uncoated catheters in terms of the number of people with symptomatic UTI because the certainty of evidence is low and the 95% CI is consistent with possible benefit and possible harm (RR 0.89, 95% CI 0.69 to 1.14; two studies; 98 participants). Uncoated catheters probably slightly reduce the risk of urethral trauma and bleeding compared to hydrophilic-coated catheters (RR 1.37, 95% CI 1.01 to 1.87; moderate-certainty evidence). The evidence is uncertain if hydrophilic-coated catheters compared with uncoated catheters has any effect on participant satisfaction measured on a 0-10 scale (MD 0.7 higher, 95% CI 0.19 to 1.21; very low-certainty evidence; one study; 114 participants). Due to the paucity of data, we could not assess the certainty of evidence relating to participant preference (one cross-over trial of 29 participants reported greater preference for a hydrophilic-coated catheter (19/29) compared to an uncoated catheter (10/29)). AUTHORS' CONCLUSIONS: Despite a total of 23 trials, the paucity of useable data and uncertainty of the evidence means that it remains unclear whether the incidence of UTI or other complications is affected by use of aseptic or clean technique, single (sterile) or multiple-use (clean) catheters, coated or uncoated catheters or different catheter lengths. The current research evidence is uncertain and design and reporting issues are significant. More well-designed trials are needed. Such trials should include analysis of cost-effectiveness because there are likely to be substantial differences associated with the use of different catheterisation techniques and strategies, and catheter designs.
Collapse
Affiliation(s)
- Jacqui A Prieto
- Faculty of Health Sciences, University of Southampton, Southampton, UK
| | | | - Fiona Stewart
- c/o Cochrane Incontinence, Population Health Sciences Institute, Newcastle University, Newcastle upon Tyne, UK
| | - Mandy Fader
- Faculty of Health Sciences, University of Southampton, Southampton, UK
| |
Collapse
|
7
|
|
8
|
Welk B, Isaranuwatchai W, Krassioukov A, Husted Torp L, Elterman D. Cost-effectiveness of hydrophilic-coated intermittent catheters compared with uncoated catheters in Canada: a public payer perspective. J Med Econ 2018; 21:639-648. [PMID: 29458282 DOI: 10.1080/13696998.2018.1443112] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
STUDY DESIGN A Markov model was used to analyze cost-effectiveness over a lifetime horizon. OBJECTIVE To investigate the cost-effectiveness of hydrophilic-coated intermittent catheters (HCICs) compared with uncoated catheters (UCs) among individuals with neurogenic bladder dysfunction (NB) due to spinal cord injury (SCI). SETTING A Canadian public payer perspective based on data from Ontario; including a scenario analysis from the societal perspective. METHODS A previously published Markov decision model was modified to compare the lifetime costs and quality-adjusted life years (QALYs) for the two interventions. Three renal function and three urinary tract infection (UTI) health states as well as other catheter-related events were included. Scenario analyses, including utility gain from compact catheter and phthalate free catheter use, were performed. Deterministic and probabilistic sensitivity analyses were conducted to evaluate the robustness of the model. RESULTS The model predicted that a 50-year-old patient with SCI would gain an additional 0.72 QALYs if HCICs were used instead of UCs at an incremental cost of $48,016, leading to an incremental cost-effectiveness ratio (ICER) of $66,634/QALY. Moreover, using HCICs could reduce the lifetime number of UTI events by 11%. From the societal perspective, HCICs cost less than UCs, while providing superior outcomes in terms of QALYs, life years gained (LYG), and UTIs. The cost per QALY further decreased when health-related quality-of-life (HRQoL) gains associated with compact HCICs or catheters not containing phthalates were included. CONCLUSION In general, ICERs in the range of CAD$50-100,000 could be considered cost-effective. The ICERs for the base case and sensitivity analyses suggest that HCICs could be cost-effective. From the societal perspective, HCICs were associated with potential cost savings in our model. The results suggest that reimbursement of HCICs should be considered in these settings.
Collapse
Affiliation(s)
- Blayne Welk
- a Department of Surgery and Epidemiology & Biostatistics , Western University , London , Ontario , Canada
- b St Joseph's Health Care , London , Ontario , Canada
| | - Wanrudee Isaranuwatchai
- c Center for Excellence in Economic Analysis Research (CLEAR), The HUB, Li Ka Shing Knowledge Institute, St. Michael's Hospital , Toronto , Ontario , Canada
- d Institute of Health Policy, Management and Evaluation, University of Toronto , Toronto , Ontario , Canada
- e Canadian Center for Applied Research in Cancer Control , Vancouver , British Columbia , Canada
| | - Andrei Krassioukov
- f ICORD, Spinal Cord Program, GF Strong Rehabilitation Center, University of British Columbia , Vancouver , British Columbia , Canada
| | | | - Dean Elterman
- h Toronto Western Hospital/Krembil Research Institute , Toronto , Ontario
- i Department of Surgery , University of Toronto , Toronto , Ontario
| |
Collapse
|
9
|
Prieto J, Murphy CL, Moore KN, Fader M. WITHDRAWN: Intermittent catheterisation for long-term bladder management. Cochrane Database Syst Rev 2017; 8:CD006008. [PMID: 28796279 PMCID: PMC6483323 DOI: 10.1002/14651858.cd006008.pub4] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND Intermittent catheterisation is a commonly recommended procedure for people with incomplete bladder emptying. There are now several designs of intermittent catheter (e.g. different lengths, 'ready to use' presentation) with different materials (e.g. PVC-free) and coatings (e.g. hydrophilic). The most frequent complication of intermittent catheterisation is urinary tract infection (UTI), but satisfaction, preference and ease of use are also important to users. It is unclear which catheter designs, techniques or strategies affect the incidence of UTI, which are preferable to users and which are most cost effective. OBJECTIVES To compare one type of catheter design versus another, one type of catheter material versus another, aseptic catheterisation technique versus clean technique, single-use (sterile) catheters versus multiple-use (clean) catheters, self-catheterisation versus catheterisation by others and any other strategies designed to reduce UTI and other complications or improve user-reported outcomes (user satisfaction, preference, ease of use) and cost effectiveness in adults and children using intermittent catheterisation for incomplete bladder emptying. SEARCH METHODS We searched the Cochrane Incontinence Group Specialised Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, MEDLINE in process, and handsearching of journals and conference proceedings (searched 30 September 2013), the reference lists of relevant articles and conference proceedings, and we attempted to contact other investigators for unpublished data or for clarification. SELECTION CRITERIA Randomised controlled trials (RCTs) or randomised cross-over trials comparing at least two different catheter designs, catheterisation techniques or strategies. DATA COLLECTION AND ANALYSIS Two review authors assessed the methodological quality of trials and abstracted data. For dichotomous variables, risk ratios and 95% confidence intervals were derived for each outcome where possible. For continuous variables, mean differences and 95% confidence intervals were calculated for each outcome. Because of trial heterogeneity, it was not always possible to combine data to give an overall estimate of treatment effect. MAIN RESULTS Thirty-one trials met the inclusion criteria, including 13 RCTs and 18 cross-over trials. Most were small (less than 60 participants completed), although five trials had more than 100 participants. There was considerable variation in length of follow-up and definitions of UTI. Participant dropout was a problem for several trials, particularly where there was long-term follow-up to measure incidence of UTI. Fifteen trials were more than 10 years old and focused mainly on comparing different catheterisation techniques (e.g. single versus multiple-use) on clinical outcomes whereas, several more recent trials have focused on comparing different types of catheter designs or materials, especially coatings, and user preference. It was not possible to combine data from some trials owing to variations in the catheters tested and in particular the catheter coatings. Where there were data, confidence intervals around estimates were wide and hence clinically important differences in UTI and other outcomes could neither be identified nor reliably ruled out. No study assessed cost-effectiveness. AUTHORS' CONCLUSIONS Despite a total of 31 trials, there is still no convincing evidence that the incidence of UTI is affected by use of aseptic or clean technique, coated or uncoated catheters, single (sterile) or multiple-use (clean) catheters, self-catheterisation or catheterisation by others, or by any other strategy. Results from user-reported outcomes varied. The current research evidence is weak and design issues are significant. More well-designed trials are strongly recommended. Such trials should include analysis of cost-effectiveness because there are likely to be substantial differences associated with the use of different catheter designs, catheterisation techniques and strategies.
Collapse
Affiliation(s)
- Jacqui Prieto
- University of SouthamptonFaculty of Health SciencesRoom AA80, South Academic Block (Mailpoint11)Southampton General HospitalSouthamptonUKSO16 6YD
| | - Catherine L Murphy
- University of SouthamptonFaculty of Health SciencesRoom AA80, South Academic Block (Mailpoint11)Southampton General HospitalSouthamptonUKSO16 6YD
| | - Katherine N Moore
- University of AlbertaFaculty of Nursing3rd Floor, Clinical Sciences BuildingEdmontonCanadaT6G 2G7
| | - Mandy Fader
- University of SouthamptonFaculty of Health SciencesRoom AA80, South Academic Block (Mailpoint11)Southampton General HospitalSouthamptonUKSO16 6YD
| |
Collapse
|
10
|
Shamout S, Biardeau X, Corcos J, Campeau L. Outcome comparison of different approaches to self-intermittent catheterization in neurogenic patients: a systematic review. Spinal Cord 2017; 55:629-643. [PMID: 28117329 DOI: 10.1038/sc.2016.192] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2016] [Revised: 12/01/2016] [Accepted: 12/11/2016] [Indexed: 02/08/2023]
Abstract
STUDY DESIGN Systematic review (Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA); http://www.prisma-statement.org). OBJECTIVES Different types of catheters and techniques have been described in the past three decades to identify the best self-intermittent catheterization method. Our aim is to review systematically the literature on the most appropriate material and technique to perform self-intermittent catheterization in the adult neurogenic population. METHODS A systematic review search was performed through PubMed/Medline, Embase and Cochrane Central Register of Controlled Trials (CENTRAL) databases to study all types of self-intermittent catheters, and analyzing their impact on urinary tract infections (UTIs), urethral trauma, cost-effectiveness, quality of life and patient's satisfaction. We used the following keywords: 'intermittent catheterization/catheterisation', 'neurogenic', 'urinary catheters for intermittent use' and 'urethral catheterization/catheterisation' published by November 2015. RESULTS After screening 3768 articles, 31 were included in the final synthesis (level of evidence 1b to 2b). The 2188 trial participants were mainly spinal cord injury adults and women with multiple sclerosis. Hydrophilic-coated catheters tended to decrease the incidence of UTI as well as urethral trauma and improve patient's satisfaction when compared with non-hydrophilic-coated catheters. Similarly, prelubricated catheters were associated with better results in terms of patient satisfaction. Sterile technique seemed to decrease the incidence of recurrent UTI; however, these results are counter-balanced by significantly increasing cost compared with clean catheterization. CONCLUSIONS The present review demonstrated advantages of hydrophilic-coated catheters in decreasing risk of UTI and urethral trauma as well as improving patient's satisfaction. Prelubricated catheters has been shown to be superior to conventional polyvinyl chloride catheters. Randomized controlled trials comparing hydrophilic and prelubricated catheters must be conducted to assess possible superiority and cost-effectiveness.
Collapse
Affiliation(s)
- S Shamout
- Division of Urology, Department of Surgery, Jewish General Hospital, Lady Davis Institute for Medical Research, McGill University, Montreal, QC, Canada
| | - X Biardeau
- Division of Urology, Department of Surgery, Jewish General Hospital, Lady Davis Institute for Medical Research, McGill University, Montreal, QC, Canada
| | - J Corcos
- Division of Urology, Department of Surgery, Jewish General Hospital, Lady Davis Institute for Medical Research, McGill University, Montreal, QC, Canada
| | - L Campeau
- Division of Urology, Department of Surgery, Jewish General Hospital, Lady Davis Institute for Medical Research, McGill University, Montreal, QC, Canada
| |
Collapse
|
11
|
Prieto JA, Murphy C, Moore KN, Fader MJ. Intermittent catheterisation for long-term bladder management (abridged cochrane review). Neurourol Urodyn 2015; 34:648-53. [DOI: 10.1002/nau.22792] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2015] [Accepted: 04/09/2015] [Indexed: 11/09/2022]
Affiliation(s)
- Jacqui A. Prieto
- University of Southampton-Faculty of Health Sciences; South Academic Block, Southampton General Hospital; Southampton United Kingdom
| | - Catherine Murphy
- University of Southampton-Faculty of Health Sciences; South Academic Block, Southampton General Hospital; Southampton United Kingdom
| | | | - Mandy J. Fader
- University of Southampton-Faculty of Health Sciences; South Academic Block, Southampton General Hospital; Southampton United Kingdom
| |
Collapse
|
12
|
Urethral strictures in men with neurogenic lower urinary tract dysfunction using intermittent catheterization for bladder evacuation. Spinal Cord 2015; 53:310-3. [PMID: 25644391 DOI: 10.1038/sc.2015.15] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2014] [Revised: 01/06/2015] [Accepted: 01/08/2015] [Indexed: 11/08/2022]
Abstract
STUDY DESIGN Retrospective investigation. OBJECTIVES To investigate the occurrence, characteristics and clinical consequences of urethral strictures in men with neurogenic lower urinary tract dysfunction (NLUTD) using intermittent catheterization (IC) for bladder evacuation. SETTING Spinal cord injury rehabilitation center. METHODS The patient database was screened for men with NLUTD who had presented for a routine video-urodynamic investigation between 2008 and 2012. Patient characteristics, bladder diary details, the occurrence of urethral strictures and performed urethrotomy procedures were collected from patient charts. Urethral strictures were classified using the Wiegand scoring system modified for men with NLUTD. RESULTS The occurrence rate of urethral strictures (that is, 25% confidence interval (CI) 21-30%) was significantly (P=0.0001) higher in men using IC (n=415) than in men using other bladder evacuation methods (that is, 14% CI 11-17%) (n=629). Urethral strictures had occurred after a median 5.9 years (range 0.5-48.9 years) of IC. There was no significant (P>0.08) effect of tetraplegia or catheter type on the stricture occurrence rate. Approximately one-third of the men suffering from urethral strictures underwent internal urethrotomies. The radiographic stricture severity score was not associated with the need for surgical correction of the stricture. The radiographic recurrence rate of urethral strictures in operated men was 100%, a median 14 years after the first urethrotomy. CONCLUSIONS The occurrence rate of urethral strictures is significantly higher in men using IC than in men using other bladder evacuation methods. Every fourth men using IC may be affected by urethral strictures. However, only every third stricture may require a surgical intervention.
Collapse
|
13
|
Pinder B, Lloyd AJ, Nafees B, Elkin EP, Marley J. Patient preferences and willingness to pay for innovations in intermittent self-catheters. Patient Prefer Adherence 2015; 9:381-8. [PMID: 25834407 PMCID: PMC4358414 DOI: 10.2147/ppa.s73487] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Intermittent catheterization is the gold standard for bladder management in Europe in people with spinal cord injuries. The aim of the present study was to identify and investigate individuals' preferences regarding intermittent self-catheterization (ISC) devices and furthermore investigate the willingness to pay for attributes in ISC devices in the UK, France, and the Netherlands. METHODS A discrete choice experiment survey was conducted to evaluate the patients' perceived value of catheter features. Attributes were selected based upon a literature review of the most important characteristics of catheters and the survey was developed and validated with input from patients and medical experts. Data were analyzed using the conditional logit model whereby the coefficients obtained from the model provided an estimate of the (log) odds ratios of preference for attributes. Willingness to pay was estimated for all levels of the attributes. RESULTS Two-hundred and eighty-three participants completed the questionnaire and were included in data analysis. Risk of infection had the highest odds ratios as preferred important attribute for all three countries followed by ease of insertion. "Pre-coated catheters" was found to be valued as the most preferred coating technology across all countries. Out of pocket cost was a significant influence on patients' choice. CONCLUSION Users of ISC perceive the value of convenience (size of catheter), ease of insertion, and reduced risk of infection as the most important features attached to an intermittent catheter. These results are applicable both for the "classic" ISC user as well as for another broad group of catheter dependent individuals.
Collapse
Affiliation(s)
| | | | - Beenish Nafees
- ICON plc, Oxford, UK
- Correspondence: Beenish Nafees, ICON plc, Seacourt Tower, West Way, Oxford OX2 0JJ, UK, Tel +44 7957 634 170, Email
| | | | - Jerome Marley
- School of Nursing, University of Ulster, Newtownabbey, UK
| |
Collapse
|
14
|
Lam TBL, Omar MI, Fisher E, Gillies K, MacLennan S. Types of indwelling urethral catheters for short-term catheterisation in hospitalised adults. Cochrane Database Syst Rev 2014; 2014:CD004013. [PMID: 25248140 PMCID: PMC11197149 DOI: 10.1002/14651858.cd004013.pub4] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Urinary tract infection (UTI) is the most common hospital-acquired infection. The major associated cause is indwelling urethral catheters. Several measures have been introduced to reduce catheter-associated urinary tract infections (CAUTIs). One of these measures is the introduction of specialised urethral catheters that have been designed to reduce the risk of infection. These include antiseptic-coated and antimicrobial-impregnated catheters. OBJECTIVES The primary objective of this review was to compare the effectiveness of different types of indwelling urethral catheters in reducing the risk of UTI and to assess their impact on other outcomes in adults who require short-term urethral catheterisation in hospitals. SEARCH METHODS We searched the Cochrane Incontinence Group's Specialised Trials Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, MEDLINE in process, ClinicalTrials.gov, WHO ICTRP and handsearching of journals and conference proceedings (searched 9 September 2014). We also examined the bibliographies of relevant articles and contacted catheter manufacturer representatives for trials. SELECTION CRITERIA We included all randomised controlled trials (RCTs) and quasi-RCTs comparing types of indwelling urethral catheters for short-term catheterisation in hospitalised adults. 'Short-term' is defined as a duration of catheterisation which is intended to be less than or equal to 14 days. DATA COLLECTION AND ANALYSIS At least two review authors independently screened abstracts, extracted data and assessed risk of bias of the included trials. Any disagreement was resolved by discussion or consultation with a third party. We processed data as described in the Cochrane Handbook for Systematic Reviews of Interventions. We assessed the quality of evidence using the GRADE approach. MAIN RESULTS Twenty-six trials met the inclusion criteria involving 12,422 hospitalised adults in 25 parallel group trials, and 27,878 adults in one large cluster-randomised cross-over trial. No trials compared one antiseptic catheter versus another, nor an antimicrobial catheter versus another. Antiseptic-coated indwelling urethral catheters versus standard indwelling urethral cathetersThe primary outcome, symptomatic CAUTI was reported in one large trial with a low risk of bias, comparing silver alloy hydrogel-coated latex catheter (antiseptic-coated) against a standard polytetrafluoroethylene (PTFE)-coated latex catheter (control). The trial used a pragmatic, US Centers for Disease Control and Prevention (CDC)-based definition for symptomatic CAUTI. For the comparison between silver alloy-coated catheter versus standard catheter, there was no significant difference in symptomatic CAUTI incidence (RR 0.99, 95% CI 0.85 to 1.16).For secondary outcomes, the included trials reported on two types of antiseptic catheters (coated with either silver oxide or silver alloy). For the outcome of bacteriuria, silver oxide catheters were not associated with any statistically significant reduction (RR 0.90, 95% CI 0.72 to 1.13). These catheters are no longer manufactured. Silver alloy catheters achieved a slight but statistically significant reduction in bacteriuria (RR 0.82, 95% CI 0.73 to 0.92). However, the one large trial with a low risk of bias did not support this finding (RR 0.99, 95% CI 0.85 to 1.16). The randomised cross-over trial of silver alloy catheters versus standard catheters was excluded from the pooled results because data were not available prior to crossover. The results of this trial showed less bacteriuria in the silver alloy catheter group.For the outcome of discomfort whilst the catheter was in-situ, fewer patients with silver alloy catheters complained of discomfort compared with standard catheters (RR 0.84, 95% CI 0.74 to 0.96). Antimicrobial-impregnated indwelling urethral catheters versus standard indwelling urethral cathetersThe primary outcome measure, symptomatic CAUTI was reported in one large trial with a low risk of bias, comparing nitrofurazone-impregnated silicone catheter (antimicrobial-impregnated) against a standard PTFE-coated latex catheter (control). The nitrofurazone catheter achieved a reduction in symptomatic CAUTI incidence which was of borderline statistical significance (RR 0.84, 95% CI 0.71 to 0.99).For secondary outcomes, the included trials reported on two types of antimicrobial catheters (impregnated with either nitrofurazone or minocycline/rifampicin). Antimicrobial-impregnated catheters, compared with standard catheters, were found to lower the rate of bacteriuria in the antimicrobial group for both minocycline and rifampicin (RR 0.36, 95% CI 0.18 to 0.73), and nitrofurazone (RR 0.73, 95% CI 0.64 to 0.85). The minocycline and rifampicin catheter is no longer manufactured.For the outcome of discomfort whilst the catheter was in-situ, more patients with nitrofurazone catheters complained of pain whilst the catheter was in-situ compared with standard catheters (RR 1.26, 95% CI 1.12 to 1.41). For the period after catheter removal, more patients with nitrofurazone catheters complained of pain than standard catheters (RR 1.43, 95% CI 1.30 to 1.57). Antimicrobial-impregnated indwelling urethral catheters versus antiseptic-coated indwelling urethral cathetersOne large trial compared antimicrobial-impregnated (nitrofurazone) catheters versus silver alloy-coated (antiseptic-coated) catheters. The results showed people were less likely to have a symptomatic CAUTI with nitrofurazone-impregnated catheters (228/2153, 10.6%) compared with silver alloy-coated catheters (263/2097, 12.5%), but this was of borderline statistical significance (RR 0.84, 95% CI 0.71 to 1.00). They did, however, have significantly less bacteriuria (RR 0.78, 95% CI 0.67 to 0.91),While the catheter was in-situ (RR 1.50, 95% CI 1.32 to 1.70), and on removal (RR 1.32, 95% CI 1.20 to 1.45), nitrofurazone catheters were associated with more discomfort compared with silver-coated catheters. One type of standard indwelling urethral catheter versus another type of standard indwelling urethral catheterNone of the trials comparing standard catheters versus other types of standard catheters measured symptomatic CAUTI. In terms of reducing bacteriuria, individual trials were too small to show whether one type of standard catheter was superior to another type. For the outcome of urethral reactions, fully siliconised catheters appeared to be superior to latex-based catheters. However, the trials involved small numbers of participants. There were no statistically significant differences between the different catheters for all other outcomes. AUTHORS' CONCLUSIONS Silver alloy-coated catheters were not associated with a statistically significant reduction in symptomatic CAUTI, and are considerably more expensive. Nitrofurazone-impregnated catheters reduced the risk of symptomatic CAUTI and bacteriuria, although the magnitude of reduction was low and hence may not be clinically important. However, they are more expensive than standard catheters. They are also more likely to cause discomfort than standard catheters.
Collapse
Affiliation(s)
- Thomas BL Lam
- University of AberdeenAcademic Urology UnitLevel 2 Health Sciences Building, Foresterhill,AberdeenScotlandUKAB25 2ZD
| | - Muhammad Imran Omar
- University of AberdeenAcademic Urology UnitLevel 2 Health Sciences Building, Foresterhill,AberdeenScotlandUKAB25 2ZD
| | - Euan Fisher
- Academic Urology UnitCochrane Incontinence Review GroupUniversity of AberdeenAberdeenUKAB25 2ZD
| | - Katie Gillies
- University of AberdeenHealth Services Research Unit3rd Floor, Health Sciences BuildingForesterhillAberdeenUKAB25 2ZB
| | - Sara MacLennan
- University of AberdeenAcademic Urology UnitLevel 2 Health Sciences Building, Foresterhill,AberdeenScotlandUKAB25 2ZD
| | | |
Collapse
|
15
|
Abstract
BACKGROUND Intermittent catheterisation is a commonly recommended procedure for people with incomplete bladder emptying. There are now several designs of intermittent catheter (e.g. different lengths, 'ready to use' presentation) with different materials (e.g. PVC-free) and coatings (e.g. hydrophilic). The most frequent complication of intermittent catheterisation is urinary tract infection (UTI), but satisfaction, preference and ease of use are also important to users. It is unclear which catheter designs, techniques or strategies affect the incidence of UTI, which are preferable to users and which are most cost effective. OBJECTIVES To compare one type of catheter design versus another, one type of catheter material versus another, aseptic catheterisation technique versus clean technique, single-use (sterile) catheters versus multiple-use (clean) catheters, self-catheterisation versus catheterisation by others and any other strategies designed to reduce UTI and other complications or improve user-reported outcomes (user satisfaction, preference, ease of use) and cost effectiveness in adults and children using intermittent catheterisation for incomplete bladder emptying. SEARCH METHODS We searched the Cochrane Incontinence Group Specialised Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, MEDLINE in process, and handsearching of journals and conference proceedings (searched 30 September 2013), the reference lists of relevant articles and conference proceedings, and we attempted to contact other investigators for unpublished data or for clarification. SELECTION CRITERIA Randomised controlled trials (RCTs) or randomised cross-over trials comparing at least two different catheter designs, catheterisation techniques or strategies. DATA COLLECTION AND ANALYSIS Two review authors assessed the methodological quality of trials and abstracted data. For dichotomous variables, risk ratios and 95% confidence intervals were derived for each outcome where possible. For continuous variables, mean differences and 95% confidence intervals were calculated for each outcome. Because of trial heterogeneity, it was not always possible to combine data to give an overall estimate of treatment effect. MAIN RESULTS Thirty-one trials met the inclusion criteria, including 13 RCTs and 18 cross-over trials. Most were small (less than 60 participants completed), although five trials had more than 100 participants. There was considerable variation in length of follow-up and definitions of UTI. Participant dropout was a problem for several trials, particularly where there was long-term follow-up to measure incidence of UTI. Fifteen trials were more than 10 years old and focused mainly on comparing different catheterisation techniques (e.g. single versus multiple-use) on clinical outcomes whereas, several more recent trials have focused on comparing different types of catheter designs or materials, especially coatings, and user preference. It was not possible to combine data from some trials owing to variations in the catheters tested and in particular the catheter coatings. Where there were data, confidence intervals around estimates were wide and hence clinically important differences in UTI and other outcomes could neither be identified nor reliably ruled out. No study assessed cost-effectiveness. AUTHORS' CONCLUSIONS Despite a total of 31 trials, there is still no convincing evidence that the incidence of UTI is affected by use of aseptic or clean technique, coated or uncoated catheters, single (sterile) or multiple-use (clean) catheters, self-catheterisation or catheterisation by others, or by any other strategy. Results from user-reported outcomes varied. The current research evidence is weak and design issues are significant. More well-designed trials are strongly recommended. Such trials should include analysis of cost-effectiveness because there are likely to be substantial differences associated with the use of different catheter designs, catheterisation techniques and strategies.
Collapse
Affiliation(s)
- Jacqui Prieto
- Faculty of Health Sciences, University of Southampton, Room AA80, South Academic Block (Mailpoint11), Southampton General Hospital, Southampton, UK, SO16 6YD
| | | | | | | |
Collapse
|
16
|
Guinet-Lacoste A, Jousse M, Verollet D, Sheikh Ismael S, Le Breton F, Tan E, Amarenco G. Validation of the InCaSaQ, a new tool for the evaluation of patient satisfaction with clean intermittent self-catheterization. Ann Phys Rehabil Med 2014; 57:159-68. [DOI: 10.1016/j.rehab.2014.02.007] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2014] [Revised: 02/28/2014] [Accepted: 02/28/2014] [Indexed: 11/17/2022]
|
17
|
Voiding Dysfunction and Upper Tract Deterioration after Spinal Cord Injury. CURRENT BLADDER DYSFUNCTION REPORTS 2013. [DOI: 10.1007/s11884-013-0200-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
18
|
Residual urine volumes after intermittent catheterization in men with spinal cord injury. Spinal Cord 2013; 51:776-9. [PMID: 23939190 DOI: 10.1038/sc.2013.81] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2013] [Revised: 06/25/2013] [Accepted: 06/27/2013] [Indexed: 11/08/2022]
Abstract
STUDY DESIGN Prospective cross-sectional study. OBJECTIVES To investigate residual urine volumes after intermittent catheterization (IC) in men with spinal cord injury (SCI) and the effect of residual urine on the rate of symptomatic urinary tract infections (UTIs). SETTING Single SCI rehabilitation center in Switzerland. METHODS Sixty men experienced in IC (≥ 6 months) emptied their bladder twice by IC. Immediately after catheterization, residual urine was determined by ultrasonography. Personal characteristics and bladder diary details (annual UTI rate, catheter type) were also collected. RESULTS The median residual urine volume was 7.0 ml (lower quartile (LQ): 0.0, upper quartile (UQ): 20.3 ml). No residual urine was observed after 42% (n=50) of all catheterizations (n=120). Unsatisfactory residual volumes (that is, >50 ml) were observed after 9% (n=11) of all catheterizations. There was no significant (P=0.95) difference between the median residual urine volume of men with recurrent (>2 UTIs per year) UTIs (2.5 ml, LQ: 0.0, UQ: 29.3 ml) and the volume of those with sporadic (≤ 2 UTIs per year) UTIs (6.0 ml, LQ: 0.0, UQ: 20.0 ml). CONCLUSIONS Bladder evacuation by IC is an efficient method, resulting in zero or small residual urine volumes. The small residual urine volumes generally observed after IC do not predispose for UTIs.
Collapse
|
19
|
Catheter length preference in wheelchair-using men who perform routine clean intermittent catheterization. Spinal Cord 2013; 51:772-5. [DOI: 10.1038/sc.2013.76] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2013] [Revised: 06/24/2013] [Accepted: 06/25/2013] [Indexed: 11/08/2022]
|
20
|
Chartier-Kastler E, Amarenco G, Lindbo L, Soljanik I, Andersen HL, Bagi P, Gjødsbøl K, Domurath B. A prospective, randomized, crossover, multicenter study comparing quality of life using compact versus standard catheters for intermittent self-catheterization. J Urol 2013; 190:942-7. [PMID: 23587630 DOI: 10.1016/j.juro.2013.04.026] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2013] [Accepted: 04/04/2013] [Indexed: 11/29/2022]
Abstract
PURPOSE Intermittent catheterization is the recommended standard treatment for neurogenic bladder dysfunction. However, standard intermittent catheters can be unwieldy, difficult to use and carry discreetly. This can influence patient ability to perform catheterization efficiently, discreetly and privately, therefore, affecting patient quality of life. We evaluated whether the discreet design of the compact catheter would improve quality of life in intermittent catheterization users compared with standard catheters. MATERIALS AND METHODS We performed a nonblinded, randomized, multicenter, 2-way crossover study with 2 treatment periods of 6 weeks ± 3 days. A total of 125 patients with neurogenic bladder dysfunction were included in the study from 17 study sites, including 7 in France, 3 each in Germany, Denmark and Sweden, and 1 in Norway. Quality of life was evaluated by the intermittent self-catheterization questionnaire. The difference in questionnaire scores between the compact catheter and standard hydrophilic coated catheters was analyzed using a mixed linear normal model. RESULTS The intermittent catheterization questionnaire score increased significantly due to compact catheter use. We noted an estimated mean difference of 17.0 between the compact and standard intermittent catheters (p <0.001), corresponding to a 28% increase. The primary study results were further supported by the positive results of the secondary objective of preference, that is 63% of patients preferred the compact catheter. CONCLUSIONS The discreet design of the compact catheter significantly improved patient quality of life related to intermittent self-catheterization.
Collapse
|
21
|
Abstract
Together with comprehension and therapy of neurogenic failure of the storage function of the urinary bladder, intermittent catheterization as a pressure-free voiding method without residual urine, represents a major principle of therapy in lower urinary tract dysfunction. Aseptic intermittent catheterization is recommended in Germany and Europe and seems to be acceptable even in long-term application with low complication rates. It is a precondition that patients are seen for clinical and urodynamic reevaluation at risk-adapted time intervals. The major focus is on early recognition and avoidance of threatening complications. The most important preventive measures are the motivation and compliance of the well-educated patient and the use of careful catheterization techniques with individually optimized catheters.Although aseptic intermittent catheterization has been used effectively for many years there is still a lack of randomized controlled studies for some important questions of details and an optimal catheter has still to be defined. Furthermore, valid conclusions based on well-conducted studies on the self-estimated quality of life of patients with intermittent catheterization, especially those with catheterization by attendant, are urgently needed. Intermittent catheterization is never a ready-made solution but always an individually tailored treatment for patients with lower urinary tract dysfunction.
Collapse
Affiliation(s)
- R Böthig
- Abteilung Neuro-Urologie, Querschnittgelähmtenzentrum, Berufsgenossenschaftliches Unfallkrankenhaus Hamburg, Bergedorfer Straße 10, 21033 Hamburg, Deutschland.
| | | |
Collapse
|